Technicolor Connected Home USA TCA200XX Touch Screen Alarm Panel User Manual 3 8 Grenada TouchScreen User Guide

Technicolor Connected Home USA LLC Touch Screen Alarm Panel 3 8 Grenada TouchScreen User Guide

Contents

Quick Start Guide

Download: Technicolor Connected Home USA TCA200XX Touch Screen Alarm Panel User Manual 3 8 Grenada TouchScreen User Guide
Mirror Download [FCC.gov]Technicolor Connected Home USA TCA200XX Touch Screen Alarm Panel User Manual 3 8 Grenada TouchScreen User Guide
Document ID1657252
Application IDE383uP5m1rXYSMqVygP7Dg==
Document DescriptionQuick Start Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize91kB (1137561 bits)
Date Submitted2012-03-15 00:00:00
Date Available2012-03-15 00:00:00
Creation Date2011-09-29 15:28:45
Producing SoftwareMadCap Flare V7
Document Lastmod2011-09-29 15:28:45
Document Title3.8 Grenada TouchScreen User Guide
Document Author: iControl Networks

TouchScreen Quick Start Guide
Technicolor TCA200
Release 3.8 Grenada
Rev 3.8 Grenada SU1
August 27, 2011
© 2006, 2007, 2008, 2009, 2010, 2011 iControl Networks, Inc., the iControl logo, uControl, Inc. the uControl logo, OpenHome,
and Converge and all other uControl products and technology names are trademarks or registered trademarks of iControl
Networks, Inc. All other products or services mentioned herein are trademarks of their respective companies.
TouchScreen Quick Start Guide
Compliances
FCC Notice
This device has been designed, constructed, and tested for compliance with FCC Rules that regulate intentional and
unintentional radiators. As the user of this device, you are not permitted to make any alterations or modifications to this
equipment or to use it in any way that is inconsistent with the information described in this guide, without the express written
permission of Technicolor. Doing so will void your authority to operate this equipment.
This device complies with FCC Rules Part 15 and Industry Canada RSS-210. Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference, including interference that may cause undesired operation of the device
Cet appareil est conformé aux FDD règles la partie 15 et RSS-210 d’Industrie Canada applicables aux appareils radio exempts
de licence. L’exploitation est autorisé aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage, et
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre
le fonctionnement.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
RF Exposure information: This devise is only authorized for use in a mobile or fixed application. At least 20cm (8 inches) of
separation distance between the touchscreen and the user’s body must be maintained at all times to ensure compliance with
the FCC and Industry Canada RF Exposure Requirements.
Informations d'exposition aux RF: Cet appareil est uniquement pour une utilisation dans une application mobile ou fixe. Au
moins 20 centimètres de distance de séparation entre l’écran tactile et le corps de l’utilisateur doit être maintenue en tout
temps pour assurer la conformité avec les exigences de la FCC et Industrie Canada, l’ exposition.
Device Purpose
Fire/Alarm Central Panel
UL and ULC Notices
This device complies with UL 985, UL1023, UL1635, ULC S545, ULC C1023.
Limitations of Security Products
Security products and alarm systems do not offer guaranteed protection against burglary, fire, or other emergencies. They may
fail to warn for diverse reasons, including (but not limited to): power failure, dead batteries, improper installation, coverage,
coverage areas overlooked during installation, defeat by technically sophisticated intruders, component failure, or inadequate
maintenance. Alarm systems should be checked weekly to ensure that all devices are working properly.
AN ALARM SYSTEM IS NOT A SUBSTITUTE FOR INSURANCE.
Using the TouchScreen
Using the TouchScreen
The Technicolor TCA200 TouchScreen is the center of your home security system. This Android-powered
device allows you to perform actions such arming and disarming your security system, monitoring the
status of your security sensors, and sending emergency alarms.
Note:
This Quick Start Guide provides an overview of the TouchScreen and its basic operation. This
guide assumes the TouchScreen has been activated and you have been assigned a security
code. For more information, see the TouchScreen User's Guide and the Home System
Installation Guide. The latest versions can be found at
http://www.icontrol.com/support/manuals/technicolor/3_8_Grenada_TouchScreen_User_
Guide_Technicolor.pdf and http://www.icontrol.com/support/manuals/technicolor/3_8_
Grenada_Home_Installation_Technicolor.pdf
For detailed information about operating an Android device, refer to the Android
documentation provided by Google.
Warning: The rechargeable battery that came with your TouchScreen is only available through your
service operator. If your battery needs to be replaced, contact your service operator to arrange for
replacement.
The following diagram shows the major components of the TouchScreen:
TouchScreen Quick Start Guide
Each button is described in the following table:
Button
Description
Home button. Press this button to go to the Home (main) screen in the TouchScreen screen.
Android menu button. Press this button to display the Android configuration menu.
Back button. Press this button to return to the previous screen.
Emergency Alarm button. Press this button to manually and immediately send an alarm to
the appropriate call center. The button is located at the bottom right in front of the device.
When A/C power is available, this button is lit. See page 10 for more information.
Understanding the Screen
The TouchScreen communicates with your security system. It combines security and home controls on a
graphical interface, providing:
A real-time view of the system statuses
Tools to manage your security system
Additional optional applications such as news and weather
The first screen displayed is the Home screen. It is from this screen that you navigate through menus by
tapping buttons to access the function you desire. If the screen is black (showing nothing) this is because
the system is not receiving A/C power or the display is powered off to conserve battery life.
The screen is divided into the following operational sections:
Security Status Header
System & Zone Trouble Header
Content Area
Security Status Header
The Security Status header displays in the upper left hand of the TouchScreen. It tells you whether the
system is armed or disarmed and other information. Tap this header to arm or disarm the system.
Also, during troubles that would prevent arming (such as a monitored door or window being opened) an
announcement replaces the Arm/Disarm status.
Using the TouchScreen
During the Exit Delay, the header changes to announce the number of seconds until the system is armed.
During the Entry Delay, the header changes to announce the number of seconds before the alarm
sounds.
System & Zone Trouble Header
The System & Zone Trouble header displays in the upper right hand of the TouchScreen. It only displays
when there is a connectivity (cellular, broadband, etc.) or power problem with the TouchScreen, when a
sensor goes down (such as due to a battery failure), or a sensor is being tampered with (such as the cover
being opened).
When the system reports a trouble, it sounds an audible alert regularly to ensure that you are aware of
the problem.
When a System & Zone header is displayed, tap it to show the Troubles list which displays all the current
troubles with the TouchScreen and sensors.
Content Area
The Content area contains the interactive functionality of your TouchScreen. The TouchScreen apps
(widgets) are displayed here. When you use or modify an app, this is where the menus and tools are
displayed.
The Home screen is the default interface when the user accesses the TouchScreen screen. It can be
accessed at any time by pressing the
button, which is located below the display area.
The TouchScreen provides the following apps:
TouchScreen Quick Start Guide
Select the Security app to view options related to
arming/disarming the system, enabling/disabling security
zones, viewing history logs, and recent security zone
events.
Select the Settings app
to access tools to modify
the TouchScreen configurations.
Understanding Arming Modes
You can arm the system by multiple scenarios:
Arm Away—Everybody leaving
Arm Stay—People are still active inside (see page 6)
Arm Night—Everybody going to bed (see page 7)
Different arming modes utilize different rules for when sensors are tripped and for Entry/Exit delays. An
Exit delay is a short period of time after the system is armed for you to leave the premises (default 60
seconds). An Entry delay is a short period of time after a sensor is tripped at an Entry/Exit door if the
system is armed (default 30 seconds). You must enter a valid keypad code within the Entry delay period
to avoid sounding an alarm. Consult with your installer or Customer Care representative to customize
the Entry/Exit delays on your system.
Note:
After the alarm is faulted the Alarm Transmission Delay period starts (see page 9).
In the Armed state and during the Entry Delay period, if the central system loses all connectivity with
your TouchScreen, an alarm is immediately sent to the central monitoring station. This prevents an
intruder from attempting to stop an alarm by destroying the TouchScreen.
Arm Away Mode
The Arm Away mode is used when everyone is leaving the house. The following rules apply:
Alarm trips immediately if a monitored Perimeter zone (non-entry/exit door or window) is opened.
Interior motion detectors are armed.
Entry/Exit zones start an Entry Delay
Exit Delay starts when the system is armed
Arm Stay Mode
The Arm Stay mode is used to arm the system when there are still people in the premises. The following
rules apply:
Alarm trips immediately if a monitored Perimeter zone (non-entry/exit door or window) is opened.
Interior motion detectors not armed.
Entry/Exit zones start an Entry Delay.
Exit Delay starts when the system is armed.
Exit Delay does not beep and is twice the length of Alarm Away mode.
Using the TouchScreen
Arm Night Mode
The Arm Night mode, is used when everyone is going to bed.
This mode works the same as Arm Stay except that there is no Entry Delay period. If an entry/exit zone is
opened, an alarm sounds immediately.
Note:
There is still an Exit Delay period that works the same as in Arm Stay mode.
Arming and Disarming the System
The Security status of your security system is displayed in the Security Status header.
Message the Security Status header displays when the
status is “Disarmed”.
Tap to arm the system.
Message the Security Status header displays when the
status is “Armed”.
Tap to disarm the system.
Arming the System from the TouchScreen
To arm the system from the TouchScreen:
1. Tap the Security Status header when it is in Disarmed state.
The Security Options screen is displayed with a keypad and the Arm System tab open.
2. Tap an arming mode (Arm Stay, Arm Away, or Arm Night) and enter your security code.
3. The Security Status header changes to display a countdown message.
The text of the message will vary, depending on which arming mode you selected.
TouchScreen Quick Start Guide
Special Rules:
If you selected the Arm Away mode, you have until the Exit Delay is over to exit the premises.
Otherwise, the system is automatically armed in Arm Stay mode. There is still an Exit Delay
period for the other Arming modes as well, but they do not require that the door open and
close during the period.
If you open and shut an Entry/Exit door during the Exit Delay and then re-enter the premise, the Exit delay restarts at 120 seconds for Arm Stay and Arm Night or 60 seconds for Arm
Away. It will only do this one time. If the wrong code is entered, the countdown timer
resets to 60 or 120 seconds.
If an Entry/Exit door is left open at the end of Exit Delay, the Entry Delay immediately starts
and, if the system is not disarmed, an alarm will sound.
Cancelling the Arming Process
If you arm the system in Arm Away or Arm Stay mode, the Security Status header displays a countdown
of the number of seconds until the Exit Delay is over. You can choose to cancel the arming process.
To cancel the arming process:
1. Tap the Security Status header while it is displaying a countdown.
The Security app is displayed with a keypad and the Disarm System tab active.
The Security app is displayed with a keypad and the Arm System tab open.
2. Enter your security code to stop the arming process.
Disarming the System
When you enter an armed premises, an Entry Delay period starts:
During the Entry Delay, the header changes to announce the number of seconds before the alarm
goes off.
Using the TouchScreen
The Security app displays a keypad.
The TouchScreen beeps audibly once every second, until the last 10 seconds when it beeps twice a
second.
If a valid keypad code is not entered by the end of the Entry Delay period, an alarm sounds. From the
time an alarm sounds (or starts silently), for most reasons, you have 30 seconds (default) to enter a valid
keypad code to disarm the system and prevent an alarm being sent to the central monitoring station.
This is called the Alarm Transmission delay or the Abort Window.
The Alarm Transmission Delay is a required period that prevents a report to the central station during an
alarm was triggered innocently.
IMPORTANT: Emergency alarms (see page 10) and smoke alarms are reported without an Alarm
Transmission delay or an Entry Delay. Consult Customer Care to understand the
number of seconds configured for the Alarm Transmission Delay in your system.
To disarm the system from the TouchScreen:
1. Tap the Security Status header when it is in Armed state.
The Security app is displayed with a keypad and the Disarm System tab active.
2. Enter your security code.
TouchScreen Quick Start Guide
If the alarm was triggered, the alarm history are displayed.
Sending an Emergency Alarm
You can manually trip an alarm in the event of an emergency by clicking the Emergency button.
Emergency alarms are reported without an Entry delay or Alarm Transmission delay.
To manually trip an alarm:
1. Press the Panic button on the lower front of the TouchScreen.
The Emergency screen is displayed.
2. Tap Fire to send an alarm for emergency fire assistance.
The TouchScreen sounds a repeating, high-pitched chime.
Tap Medical to send an alarm for emergency medical assistance.
The TouchScreen sounds an audible, repeating, triple beep signal.
Tap Police to send an alarm for police assistance.
By default the TouchScreen will not issue an audible signal. The TouchScreen displays a Police
Panic In Progress alert on the TouchScreen. Tap the alert to sound an audible, continuous, highpitched chime.
10
Using the TouchScreen
Evacuation Plan
Develop an emergency evacuation plan for use in the event of fire. Here are some recommendations
from the National Fire Protection Association.
Make an evacuation plan for how to leave your home in the case of fire or other emergency.
Sketch a map of your home that shows all the doors and windows. Discuss the plan with everyone
in your home so that everyone will know what to do.
Have at least two ways to exit each room. Make sure that windows and doors open easily.
Discuss with your family and agree on a single meeting location outside your home.
In the event of fire, get out and stay out. Don’t go back inside for people, pets or possessions.
Do not open a door if the handle is hot.
If there is smoke stay low to the ground and go under the smoke.
Escape your home before calling the fire department. Call the fire department and police from the
outside meeting place using your cell phone or call from a neighbor’s phone.
Practice your home evacuation plan.
Additional Emergency Preparations
Do not wait until an emergency occurs to make a plan. Talk to each other about what each person
should do in different types of emergency.
Learn your security system. Get to know how to arm and disarm it and what to do when the
authorities or central monitoring calls.
Make sure everyone (who should know) knows the Secret Word, when to use it, and that it
should not be shared.
Understand the difference between your keypad code and the duress code.
Understand that you should never enter the premises if you hear an alarm. Call police from a cell
phone or a neighbor’s phone.
11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Title                           : 3.8 Grenada TouchScreen User Guide
Author                          : iControl Networks
Producer                        : MadCap Flare V7
Subject                         : 
Modify Date                     : 2011:09:29 15:28:45-05:00
Create Date                     : 2011:09:29 15:28:45-05:00
Page Count                      : 11
Language                        : en-us
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools
FCC ID Filing: G95TCA200XX

Navigation menu