Teko Telecom Srl LOWPOWER6 OPTICAL SYSTEMS User Manual

Teko Telecom Srl OPTICAL SYSTEMS

User Manual

Download: Teko Telecom Srl LOWPOWER6 OPTICAL SYSTEMS User Manual
Mirror Download [FCC.gov]Teko Telecom Srl LOWPOWER6 OPTICAL SYSTEMS User Manual
Document ID1519047
Application IDqffVFA/iqQlZjRrtqiJlPw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize326.77kB (4084629 bits)
Date Submitted2011-08-08 00:00:00
Date Available2011-08-09 00:00:00
Creation Date2011-08-01 13:50:59
Document Lastmod2011-08-05 17:09:05
Document TitleUser Manual

www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
SIRIUS: Teko Telecom Modular Coverage and Capacity System
TECHNICAL HANDBOOK
Doc ID Number 91 080 0781 - Rel. 02
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
SIRIUS: Teko Telecom Modular Coverage and Capacity System
BOLOGNA, 11/10/2010
UPDATINGS:
Rel. 02 (11/04/2011)
.........................................
.........................................
Document Identification Number
91 080 0781 – Rel. 02
Doc ID Number 91 080 0781 - Rel. 02
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Table of Contents
1. Teko Telecom Modular Coverage and Capacity System - General Description................ 9
1.1 Components........................................................................................................................... 10
1.1.1 Modules providing the RF interface towards the signal source....................................... 12
1.1.2 Equipment extending coverage / distributing capacity...................................................... 19
1.1.3 Modules providing the optical interface towards Remote Units..................................... 22
1.1.4 Passive Modules providing distribution and filtering.......................................................... 29
1.1.5 Modules for the management of the System.......................................................................... 34
1.1.6 Power Supply Modules.................................................................................................................... 39
1.1.7 Subracks hosting the System modules...................................................................................... 41
1.1.8 Forced-air cooling Subrack............................................................................................................. 43
1.2 Coverage and Capacity Solutions....................................................................................... 44
1.2.1 Modular Off-air Repeaters - General description................................................................... 44
1.2.2 Optical Systems - General Description....................................................................................... 47
A – Master Unit............................................................................................................................................ 47
B – Remote Units........................................................................................................................................ 53
1.2.3 Coverage Systems Management and Power Supply............................................................ 61
1.2.4 Teko Telecom Coverage Systems Technical Specifications................................................. 65
2. System Installation.................................................................................................................... 68
2.1 Mechanical Installation........................................................................................................ 69
2.1.1 Positioning Master Unit Subracks................................................................................................ 71
2.1.2 Positioning Remote Units............................................................................................................... 72
2.2 Connections............................................................................................................................ 74
2.2.1 RF Connections................................................................................................................................... 75
2.2.2 RS485 Connections.........................................................................................................................103
A – Connecting monitored subracks mounted within the same rack hosting the
Master subrack.........................................................................................................................................104
B – Connecting remote monitored subracks.................................................................................105
2.2.3 Optical Connections.......................................................................................................................106
A – Connecting Master Unit to Remote Units................................................................................107
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 3
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
B – Connecting Master point to point Modules to Slave point to point Modules...........109
2.2.4 Power Supply Connections..........................................................................................................110
A – Active Subracks Power Supply Connection............................................................................111
B – Remote Units Power Supply Connection and Alarms Connection.................................114
2.3 Power-Up...............................................................................................................................117
3. System Commissioning...........................................................................................................119
4. Preventive Maintenance.........................................................................................................121
4.1 Optical Fibres........................................................................................................................121
4.2 Remote Units........................................................................................................................121
4.2.1 Remote Units with passive cooling system (natural convection - fan unit not
equipped).......................................................................................................................................................121
4.2.2 Remote Units with active cooling system (equipped with the fan unit).....................121
5. Troubleshooting.......................................................................................................................124
5.1 Troubleshooting procedures.............................................................................................128
5.1.1 Active RF Interface Modules........................................................................................................128
A – Digital Donor Front End module - MU-DFE.............................................................................128
B – Point of Interface module with remote controlled attenuators- TAPOI........................132
5.1.2 Modules for the management of the System........................................................................133
5.1.3 Power Supply Modules..................................................................................................................134
5.1.4 Modules providing the optical interface towards Remote Units...................................135
A – Fiber Optic Transmitter/Receiver modules - MU-OTRX.......................................................135
B – Master and Slave Point to Point modules - MU-PTP.............................................................137
5.1.5 Equipment extending coverage/ distributing capacity.....................................................141
A – Service Front End Subrack.............................................................................................................141
B – Very High/High/Medium power Remote Unit........................................................................142
C – SFE Subrack / Very High/High/Medium power Remote Unit amplifiers.......................145
D – Very High/High/Medium power Remote Unit modules....................................................147
E – Single/Dual/Triband Low power Remote Unit.......................................................................150
F – 6-band Low power Remote Unit.................................................................................................154
5.1.6 Forced-air cooling subrack...........................................................................................................159
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 4
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
5.2 Flow charts............................................................................................................................160
5.2.1 Received Optical Power out of range - Uplink path............................................................161
5.2.2 Received Optical Power out of range - Downlink path.........................................................162
5.3 Replacement Instructions..................................................................................................163
5.3.1 Replacing the fan unit....................................................................................................................163
5.3.2 Replacing plug-in modules..........................................................................................................164
5.3.3 Extracting guide rails for plug-in modules from active subracks...................................164
5.3.4 Cleaning optical connectors . .....................................................................................................165
Attached Documents
Safety Rules
Standards
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 5
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Initial Notes
Declaration of Conformity (*)
According to Directive 1999/5/EC (R&TTE)
We TEKO TELECOM hereby declare that the products described in this technical handbook are manufactured by TEKO TELECOM S.p.A. Via
Meucci, 24/a 40024 Castel S. Pietro Terme (Bologna) – ITALY. All the above cited products are compliant with the essential requirements of
article 3 and other relevant provisions of the Radio & Telecommunications Terminal Equipment Directive, n.1999/5/EC, when used for their
intended purpose: improving coverage of mobile communication networks.
Castel S. Pietro Terme (Bologna) – ITALY
Legal representative
Teko Telecom S.p.A.
a Socio Unico
(*) A signed copy of the conformity declaration is available upon request. Please get in touch with our after sale service, filling in the form on
line at the following Internet address: www.tekotelecom.it
Note relevant to product utilization within the European Union (EU)
It’s under user’s own responsibility to verify to be compliant to the National provisions or authorisations required.
For further information refer to: http://ec.europa.eu/enterprise/sectors/rtte/index_en.htm
EU directive 2002/96/EC – WEEE (Waste Electrical and Electronic Equipment)
This product complies with the EU directive 2002/96/EC – WEEE (Waste Electrical and Electronic Equipment)
The symbol of the crossed container marked on the equipment shows that the product, at the end of its
useful life, must be collected separately from other refuse. Therefore the user must deliver the equipment
that has reached the end of its life to the special differentiated electronic and electrotechnical refuse
collection centres, far subsequent dispatch of the discarded equipment for recycling, treatment and
environmentally compatible disposal, thus contributing in preventing possible negative effects on the
environment and on health and favouring the recycling of the materials from which the equipment is
made.
Illicit disposal of the product by the user will lead to the application of the penalties provided far by the
national legislations of the various Member States on receipt of directive 2002/96/EC.
For further information, please contact our after sales department: www.tekotelecom.it
Packaging and Packaging Waste Directive 94/62/EC
The packaging of the product complies with the Directive 94/62/EC, concerning packaging and packaging waste. Environmentally harmful
materials are not used for packaging.
Packaging is made from materials that can easily be recycled after use. Depending on the means of transportation, the equipment is packed
in a cardboard or wooden box, protected with expanded polystyrene or barrier bags.
The packaging materials are marked according to ISO 11 469.
Please do not throw packaging materials into unsorted waste but separate them according to local regulations waste disposal options.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 6
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Operation is subject to the following conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 50 cm for Low Power family in Tri-Band
system (with 8dB of maximum antenna gain for operating bands lower than 1.5GHz and 11dB for operating bands higher than 1.5GHz), at
least 50 cm for Low Power family in Six-Band system (with 4.5dB of maximum antenna gain for operating bands lower than 1.5GHz and 6.5dB
for operating bands higher than 1.5GHz) and at least 150 cm for Very High Power family in Tri-Band System (with 3.5dB of maximum antenna
gain for operating bands lower than 1.5GHz and 6.5dB for operating bands higher than 1.5GHz) from all persons assuming no co-location or
operating in conjuction with any other antenna or transmitter.
With higher maximum gain and/or co-location higher separation distance is required and shall be calculated accordingly by the installer. For
Low Power family in Tri-Band system with 16dB of maximum antenna gain, the separation distance from nearby people shall be 130 cm for
operating bands lower than 1.5GHz, and 90 cm for operating bands higher than 1.5GHz. For Low Power family in Six-Band system with 16dB
of maximum antenna gain, the separation distance from nearby people shall be 190 cm for operating bands lower than 1.5GHz, and 145 cm
for operating bands higher than 1.5GHz. For Very High Power family in Tri-Band system with 16dB of maximum antenna gain, the separation
distance from nearby people shall be 630 cm for operating bands lower than 1.5GHz, and 450 cm for operating bands higher than 1.5GHz.
Specifications of antennas, cables, RF components, etc will be provided only in the final installation phase, being the external antenna not
provided with equipment.
Equipment will be accessible only to maintenance men, that must switch it off before any maintenance operation.
Teko Telecom Coverage and Capacity Systems Technical Handbook
© Copyright 2010 Teko Telecom S.p.A. All rights reserved.
The content of this manual is for informational use only. Information and specifications regarding the products described in this document
are subject to change without notice. The images shown in this document are for illustrative purposes only.
Teko Telecom shall not be liable for technical or editorial errors contained in this manual.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 7
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
SIRIUS: Teko Telecom Modular Coverage and Capacity System
1.General Description
Doc ID Number 91 080 0781 - Rel. 02
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1. Teko Telecom Modular Coverage and Capacity System - General
Description
Teko Telecom Coverage and Capacity Systems are flexible multi-band multi-operator Systems
that provide a wide range of solutions to extend both indoor and outdoor cellular coverage
in shadow areas -where the RF signal is not available- and to increase capacity in indoor and
outdoor hot spots -where the operators need a dedicated coverage.
Modular design is a key feature of Teko Telecom Coverage and Capacity Systems: it offers
flexible configuration options to build the most suitable solution for any coverage need.
SIRIUS
Stand-alone Modular Repeaters, Optical Systems as well as integrated solutions share a unique
common platform: SIRIUS.
SIRIUS includes a wide range of active and passive components that can be assembled in a
variety of ways in order to provide easy to set-up, maintain, and upgrade products operating
in the 380 to 2700MHz frequency range.
SIRIUS components can be used in different Systems with different functionalities to meet
present needs and to allow system adaptation to changing conditions, always assuring
optimized performances.
Teko Telecom Master Unit is the core of SIRIUS modular design: it is a versatile modular rackbased platform that controls the whole Coverage System and, depending on its components
configuration, is able to provide:
• the RF interface towards the signal source (BTS, Node B, Repeater),
• the RF interface towards Service Antennas/leaky cable,
• the optical interface towards up to 144 Remote Units.
This technical handbook describes the components of SIRIUS and how these components can
be assembled to provide Optical Systems and Modular Off-air Repeaters to improve coverage
in different environments.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 9
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1 Components
The components of SIRIUS, Teko Telecom Modular Coverage and Capacity System, can be
grouped in the following categories:
1. Modules providing the RF interface towards the signal source
• Point of Interface (POI) module: it is the single-band/single-operator interface towards
a BTS or NodeB. The Point of Interface module is connected to the signal source via
coaxial cable.
• Digital Donor Front End Module: it is the single-band/single-operator interface
towards a Donor Antenna, providing a connection to a BTS or NodeB over an air link.
2. Equipment extending coverage / distributing capacity
• Service Front End: it is the single-band/multi-operator interface towards a Service
Antenna. It provides wireless signal to the area to be covered (Modular Repeaters).
In Optical Systems the Service Front End can be used to extend coverage to the area
close to the Master Unit site.
• Remote Unit: it is the multi-band/multi-operator equipment used in Optical Systems
to distribute wireless signal throughout the area to be covered (extensive areas
coverage/active DAS).
3. Modules providing the optical interface towards Remote Units
• Fiber Optic Transmitter/Receiver Modules are the optical interface between Master
Unit and Remote Units: they provide RF-to-Optical/Optical-to-RF conversion.
• Master and Slave Point to Point Modules perform the RF-to-Optical/Optical-to-RF
conversion required by the optical point to point link connecting RF Interface modules
to distant Fiber Optic Transmitter/Receiver Modules. The optical point to point link
allows a separation distance -up to 20km- between RF Interface modules and Fiber
Optic Transmitter/Receiver Modules.
4. Passive Modules providing distribution and filtering
Due to the flexible configuration options of Teko Telecom Coverage and Capacity Systems,
the same passive components can be used for different purposes.
• The 4-way Combiner/Splitter can be used to manage either up to 4 RF interface
modules, operating in the same band (Multi-Operator Systems) or up to 4 Fiber
Optic Modules (Fiber Optic Transmitter/Receiver Modules or Master Point to Point
Modules).
• The Band Splitter/Combiner (Triplexer) with built-in 1:4 Splitter/Combiner
can be used to manage up to 3 RF interface modules or Service Front End subracks,
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 10
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
operating in different bands, and up to 4 Fiber Optic Modules. It can also manage
up to 3 four-way splitter/combiner modules each connected to multiple RF interface
modules, operating in the same band, and up to 4 Fiber Optic Modules.
5. Modules for the management of the System
• The Supervision Module allows the management of the whole Coverage System.
• The Alarm Module is an optional module that can be equipped to increase the number
of supported external alarms.
6. Power Supply Modules
The Coverage and Capacity Systems can be equipped with either AC (Universal mains,
85÷264Vac, 50-60Hz) or DC (-72÷-36Vdc) Power Supply modules.
7. Subracks hosting the System modules
Both active and passive subracks are available.
• Active subracks are provided with a backplane that allows the management and
power supply of active modules.
• Passive subracks are used to host passive modules that do not require power nor
management to function. Passive Subracks allow a reduction in the cost of the whole
system.
8. Forced-air cooling Subrack
A forced-air cooling subrack is available to ensure the air flow required for proper cabinet
installed equipment operation.
Rack cabinets for hosting the System Subracks (indoor installation) and cabinets for Outdoor
installation are also available.
A detailed description of each Component of Teko Telecom Modular Coverage and Capacity
System is provided in the following paragraphs.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 11
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1.1 Modules providing the RF interface towards the signal source
• Point Of Interface Modules
Point of Interface modules are used in Optical Systems to interface any kind of operator signal
source -pico/micro/macro BTS or NodeB: each Point of Interface module is connected to a
single mobile operator/ mobile band signal source via coaxial cable.
Optical Systems can be equipped with one Point of Interface or more Point of Interface
modules to make multiple configurations available: single operator (single band / multi-band)
and multi-operator (single-band / multi-band).
Passive Point Of Interface module (POI)
with rotary adjustable attenuators
Point Of Interface module (TAPOI) with
remote-controlled variable attenuators
Each Point of Interface module includes the duplexer, to separate/combine Downlink and
Uplink paths and two variable attenuators to make both Downlink and Uplink RF levels
separately adjustable.
A monitor port is available either for measurements or for external wireless modem
coupling.
DL
DL-OUT
BTS PORT
MONITOR
UL
UL-IN
Point Of Interface module block diagram
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 12
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Point of Interface modules with separate Downlink and Uplink ports (without built-in duplexer)
are available as option.
Teko Telecom Point of Interface modules can be equipped either with manually adjustable
attenuators (POI-x models) or with remote-controlled attenuators (TAPOI-x models).
POI modules
POI modules include two rotary adjustable attenuators to make Downlink and Uplink RF
levels manually adjustable within a range of either 30dB, with 1dB step, or 10dB, with 1dB
step (POI-A10 models).
TAPOI modules
TAPOI modules include two automated variable attenuators to adjust Downlink and Uplink
RF levels via the Coverage System Supervision Module (TSPV) and Management Tools (OMT
webpages, OMC software).
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 13
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
•
POI Modules Access Points
Adjustable
attenuators
Passive POI with built-in duplexer
Adjustable
attenuators
Passive POI without built-in duplexer
Description
Label
(Connectors)
Downlink path RF output
DL-OUT
(SMA connector)
Uplink path RF input (SMA
UL-IN
connector)
RF connector (N type )
BTS PORT
towards the signal source
(BTS, Node B or repeater)
Description
Label
(Connectors)
Downlink path RF output
DL-OUT
SMA connector
Uplink path RF input SMA
UL-IN
connector
Input RF connector from the
BTS PORT DL signal source - BTS, Node B
or repeater (N type)
Monitor port for
measurements or for external
wireless modem coupling
Output RF connector to the
BTS PORT UL signal source - BTS, Node B
or repeater (N type)
MONITOR
Adjustable Description
attenuators
DL OUT
Downlink path RF level adjustable attenuator (0÷30dB or 0÷10dB - 1 dB step)
UL IN
Uplink path RF level adjustable attenuator (0÷30dB or 0÷10dB - 1 dB step)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 14
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
•
TAPOI Modules Access Points
TAPOI with built-in duplexer
Label
(Connectors)
Description
DL OUT
Downlink path RF output (SMA connector)
UL IN
Uplink path RF input (SMA connector)
BTS PORT
MONITOR
Label
(LEDs)
ON
ALM
RF connector (N type ) towards the signal source (BTS, Node B
or repeater)
Monitor port for measurements or for external wireless modem
coupling
Description
TAPOI Module operating status green LED
ON when power supply is present
TAPOI Module alarm status LED:
OFF: regular operation
Blinking Orange: presence of active alarms with warning
severity level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity
level (2)
Red: presence of active alarms with critical severity level (1)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 15
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
• Teko Telecom Digital Donor Front End
The Digital Donor Front End Module is the single-band/single-operator System RF interface
towards a Donor Antenna. No physical connections are required between the DFE and the
cellular network: the Donor Antenna provides the connection to a BTS or NodeB over an air
link.
Coverage Systems can be equipped with one or more Donor Front End modules to make
multiple configurations available: single operator (single band / multi-band) and multioperator (single-band / multi-band).
A single-band single-operator modular Off-air Repeater can be set up combining a Digital
Donor Front End Module and a Service Front End (Teko Telecom single-band/multi-operator
interface towards a Service Antenna). Up to 4 Donor Front End Modules can be connected to
a single Service Front End to provide a single-band 4-operator modular Off-air Repeater.
Digital Donor Front End Modules can also be used to drive Optical Systems: the Digital Donor
Front End Module allows Optical Systems to be driven without the need of a dedicated BTS or
Node B. A donor antenna picks-up the signal and the Optical System acts as a repeater with
distributed Service antennas connected to the Remote Units. Service Front End subracks can
be connected to DFE modules to provide coverage to the area next to the Master Unit site.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 16
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Each DFE module hosts the duplexer, to be connected to the Donor Antenna to separate/
combine downlink and uplink paths.
In downlink the signal from the Donor Antenna is preamplified by a Low Noise Amplifier and
converted into an IF signal by a downconverter. The selection of the band of frequencies or
channels to be extended is handled by a digital filter.
The digital filter can manage 1 variable band or 2 variable sub-bands.
An upconverter converts the IF signal into the RF output signal.
In uplink the signal from the Service Front End Subrack or from the Optical System is converted
into an IF signal by a downconverter, filtered and re-converted into an RF signal, amplified by
a power amplifier and re-transmitted to the signal source.
LNA
Donor
Antenna
Port
DL RF
Out
Digital Filter
DUPLEXER
PA
UL RF
In
Digital Filter
+12V +3.3V +1.8V
μP
DC/DC
FANS
RS485
28VDC
Digital Donor Front End Module block diagram
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 17
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Digital Donor Front End Module Access Points
Label
(Connectors)
DL
UL
Description
Downlink path RF output (SMA connector) to Service Front End
or Fiber Optic Modules
Uplink path RF input (SMA connector) from Service Front End
or Fiber Optic Modules
DONOR ANT
Donor Antenna Port (N type connector)
Label
(LEDs)
Description
ON
ALM
Digital Donor Front End Module operating status green LED:
ON when power supply is present
Digital Donor Front End Module alarm status LED:
OFF: regular operation
Blinking Orange: presence of active alarms with warning
severity level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity
level (2)
Red: presence of active alarms with critical severity level (1)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 18
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1.2 Equipment extending coverage / distributing capacity
• Teko Telecom Service Front End
Teko Telecom Service Front End Subrack is a single-band/multi operator equipment, driven
by Digital Donor Front End Modules and connected to a Service Antenna to provide wireless
signal to the area to be covered. The equipment is available in four different power classes:
Very High, High, Medium and Low.
A single-band single-operator modular Off-air Repeater can be set-up combining a Digital
Donor Front End Module and a Service Front End. Up to 4 Donor Front End Modules can
be connected to a single Service Front End subrack to provide a single-band 4-operator
Repeater.
The Service Front End subrack can also be used in Optical Systems to provide coverage to the
area adjoining the Master Unit site.
The SFE 19”/2U subrack hosts the duplexer, to be connected to the Service Antenna to
separate/combine Downlink and Uplink paths.
In Downlink the signals from the Donor Front-End Modules are combined and amplified by a
Power Amplifier.
In Uplink, the RF signal from the Service antenna is amplified by a Low Noise Amplifier (LNA)
and split to feed up to 4 Donor Front-End Modules.
Auxiliary ports are available to drive an Optical System.
DL in1
Digital
Attenuator
DL in2
PA
From DFEs
DL in3
DL in4
4:1
Digital
Attenuator
To Optics
Service
Antenna
Port
Duplexer
DL out
UL out1
Digital
Attenuator
UL out2
LNA
To DFEs
UL out3
UL out4
4:1
+3.3V +5V
Digital
Attenuator
From Optics
μP
DC/DC
FANS
UL in
RS485
28VDC
Service Front End Module block diagram
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 19
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Service Front End Module Access Points
Label
(Connectors)
Description
DL TO OPT
Downlink path RF output (SMA connector) - to Optics
UL FROM OPT
Uplink path RF input (SMA connector) - from Optics
SERVICE ANT
Service Antenna Port (N type )
DFE1
DFE2
DFE3
DFE4
Label
(LEDs)
LED
DL
UL
DL
UL
DL
UL
DL
UL
Downlink path RF input (SMA connector) - from Digital Donor
Front End 1
Uplink path RF output (SMA connector) - to Digital Donor Front
End 1
Downlink path RF input (SMA connector) - from Digital Donor
Front End 2
Uplink path RF output (SMA connector) - to Digital Donor Front
End 2
Downlink path RF input (SMA connector) - from Digital Donor
Front End 3
Uplink path RF output (SMA connector) - to Digital Donor Front
End 3
Downlink path RF input (SMA connector) - from Digital Donor
Front End 4
Uplink path RF output (SMA connector) - to Digital Donor Front
End 4
Description
Service Front End subrack general operating status LED
Green: no alarm
Blinking Orange: presence of active alarms with warning
severity level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity
level (2)
Red: presence of active alarms with critical severity level (1)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 20
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
• Teko Telecom Remote Units
Remote Units are used in Optical Systems to distribute wireless signals throughout the area
to be covered. They are connected to the Fiber Optic Transmitter/Receiver Modules equipped
in the Master Unit.
Remote Units are equipped with the Fiber Optic Receiver and Transmitter module (for Optical
to RF and RF to Optical conversion), power amplifiers and filtering.
They can be Single, Dual or Tri-band with four different RF power classes: Very High, High,
Medium and Low.
Remote Units with different power classes can be driven simultaneously by the same Master
Unit to distribute capacity or extend coverage into different locations at the same time.
Very High, High and Medium Power Remote Units are equipped in a weatherproof IP66
case. Low Power Remote Units are equipped in an IP32 case; a protection kit, providing IP66
protection degree, is available as option for installation in harsh environments.
Single, Dual or Tri-band Very High, High and
Medium Power Remote Unit
Single, Dual or Tri-band Low Power Remote
Unit
Please refer to Paragraph 1.2.2 for a detailed description of Remote Units.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 21
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1.3 Modules providing the optical interface towards Remote Units
• Fiber Optic Transmitter/Receiver Modules
Fiber Optic Transmitter/Receiver Modules are the optical interface between Master Unit and
Remote Units: they provide RF-to-Optical/Optical-to-RF conversion. They are connected to
Remote Units via single mode optical fibers, with Uplink and Downlink signals transmitted
over the same fibre (Wavelength Division Multiplexing -WDM technology).
Different modules configurations are available: a single Fiber Optic Transmitter/Receiver
Module can be equipped with 1 Optical Transmitter and 1 Optical Receiver (10dB optical link
budget, up to 20km distance - 12.4 miles), or 1 Optical Transmitter split by 2 and 2 combined
Optical Receivers (10dB optical link budget, up to 20km distance- 12.4 miles), or 1 Optical
Transmitter split by 4 and 4 combined Optical Receivers (6dB optical link budget, up to 12km
distance - 7.5 miles).
The Fiber Optic Transmitter/Receiver Module in 1:4 configuration can manage up to 4 Remote
Units.
The Fiber Optic Transmitter/Receiver Module in 1:1 configuration is able to drive up to 5
cascaded Remote Units with different wavelengths in Up-link.
Fiber Optic Transmitter/Receiver Module equipped with 1 Optical Transmitter split by 4 and 4 combined
Optical Receivers
The Fiber Optic Transmitter provides the RF to optical conversion (Downlink side): the module
RF section covers the 380 to 2200MHz band (TTRC models) or the 380 to 2700MHz band
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 22
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
(TTRU models).
Fiber Optic Receivers convert uplink optical signals from Remote Units into RF. They operate
in the third window (Optical wavelength 1490 ÷ 1570 nm).
Each Fiber Optic module is controlled by a microprocessor which provides the following data
to the Supervision Module:
-- optical power received by each optical receiver,
-- Downlink attenuator and Uplink attenuator attenuation setting (0 ÷ 15dB),
-- received optical power alarms.
An auto-levelling functionality (AGC) compensates up to 10dB optical link loss in order
to guarantee constant gain over different optical budgets. This feature simplifies system
installation, makes commissioning quick and easy and avoids field adjustments.
WDM
DL/UL 1
Laser
1:4
Opt
DL RF
DL/UL 2
DL/UL 3
DL/UL 4
CONTROL
MODEM
UL RF
PA
Digital
Attenuator
LNA
PA
Digital
Attenuator
LNA
PA
Digital
Attenuator
LNA
PA
Digital
Attenuator
LNA
4:1
μP
DC/DC
RS485
28VDC
Block diagram: Fiber Optic Transmitter/Receiver Module equipped with 1 Optical Transmitter split by 4 and 4
combined Optical Receivers (WDM technology)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 23
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Fiber Optic Transmitter/Receiver Module Access Points
Fiber Optic Module equipped with 1 Transmitter
split by 4 and 4 combined Receivers - WDM
Fiber Optic Module equipped with 1 Transmitter
split by 4 and 4 combined Receivers
Optical Connectors
DL
UL
RF Connectors
DL RF
UL RF
Description
Fiber Optic Transmitters (1 to 4) optical output SC-APC connectors
Fiber Optic Receivers (1 to 4) optical power input SC-APC connectors
Description
Fiber Optic Transmitter RF input SMA connector
Fiber Optic Receiver RF output SMA connector
LEDs
Description
Fiber Optic Module operating status green LED
ON when power supply is present
Fiber Optic Module alarm status LED:
OFF: regular operation; BLINKING ORANGE/ORANGE: warning/minor;
BLINKING RED/RED: major/critical
These LEDs describe the general operating status of Remote Units (1 to
4) connected to Fiber Optic Transmitters (DL) and Repeaters (UL) .
Each pair of DL/UL leds takes the same color as the general operating status led
of the Remote Unit connected to the relevant optical connector, except when
• a Laser Fault occurs in the Fiber Optic transmitter. If this fault occurs, all
DL leds turn RED and the ALM Led switches on (RED).
• a Low Optical Power alarm arises in the Fiber Optic receiver. If this alarm
arises, the relevant UL led turns RED and the ALM Led switches on (RED).
Each pair of DL/UL LEDs can be:
Green: Remote Unit status OK
Blinking Orange: presence of RU active alarms with warning severity level (4)
Orange: presence of RU active alarms with minor severity level (3)
Blinking Red: presence of RU active alarms with major severity level (2)
Red: presence of RU active alarms with critical severity level (1)
ON
ALM
DL UL
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 24
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
• Master and Slave Point to Point Modules
Master and Slave Point to Point Modules provide an optical point to point link allowing a
separation distance -up to 20km- between RF interface subracks and optical subracks.
The point to point link is suitable when the signal source (BTS, Node B, Repeater) is located
far from the area to be covered or when the same optical system provides coverage to several
separate buildings; in these applications the point to point link allows the transmission of
signals from/to a group of remote units over a single optical fibre, thus providing a significant
reduction in the number of fiber optics running long distances.
The point to point link requires the RF interface subracks to be equipped with Master Point
to Point modules and the remote optical subracks to be equipped with Slave Point to Point
modules. The RF Interface subracks can be equipped with up to 4 Master Pont to Point modules
for the management of up to 4 optical subracks, installed in different remote locations.
Master Point to Point Module
Slave Point to Point Module
Each Master Point to Point Module is connected to a Slave Point to Point Module, equipped in
a remote optical subrack, via a single optical fibre (single-mode SMR 9/125).
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 25
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Point to Point Modules (Master and Slave) perform the electrical-to-optical/optical-toelectrical conversion required for the transmission of downlink and uplink signals over the
connecting optical fibre.
Att.
1310nm
Coupler
DL RF input
SMA (f )
RS485
port
μP
Modem
WDM
DL/UL
optical SC/APC
connector
UL RF output
SMA (f )
Coupler
Att.
1550nm
Master Point to Point Module Module block diagram
The Slave Point to Point module includes the 4-way splitter/combiner to manage up to 4 Fiber
Optic Transmitter/Receiver Modules. A built-in Supervision unit controls the remote optical
subrack, hosting the Slave Point to Point module, and all connected Remote Units.
The Coverage System Supervision Module communicates with the Slave Point to Point module
built-in Supervision unit via the single-mode optical fiber connecting Master and Slave Point
to Point modules.
An RS232 port on the Slave Point to Point Module front panel allows local communication
with the built-in supervision.
1310nm
Att.
Coupler
DL RF outputs
SMA (f )
connectors
DL/UL
optical SC/APC
connector
WDM
Modem
Att.
UL RF inputs
SMA (f )
connectors
1550nm
μP
RS232
Slave Point to Point Module Module block diagram
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 26
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Master Point to Point Module Access Points
Master Point to Point Module
Label (Connectors) Description
DL UL
Optical power input/output SC-APC connector (from/to Slave Point to
Point Module)
RS485
RJ45 connector for RS485 connection to the Supervision Module
DL
RF input SMA connector (from the System RF Interface modules)
UL
RF output SMA connector (to the System RF Interface modules)
Label (LEDs)
ON
ALM
DL
UL
Description
Master Point to Point Module operating status green LED:
ON when power supply is present
Point to Point Module alarm status LED:
OFF: regular operation
Blinking Orange: presence of active alarms with warning severity level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity level (2)
Red: presence of active alarms with critical severity level (1)
Fiber Optic Transmitter operating status LED:
BLINKING GREEN: the module is reaching its operating temperature
GREEN optical output power is available
ORANGE: warning: optical output power is degradated
RED: Laser Fault: no optical output power
Fiber Optic Receiver operating status LED:
GREEN: +6dBm to -4dBm optical input power
YELLOW: -4dBm to -5dBm optical input power
RED: optical input power is >+6dBm or <-5dBm
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 27
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Slave Point to Point Module Access Points
Slave Point to Point Module
Label (Connectors) Description
DL UL
Optical power input/output SC-APC connector (from/to Master Point to
Point Module
9-pole D-Sub RS232 connector for connection to an external modem
RS232
(Local Management)
DL
RF output SMA connectors (to Fiber Optic Modules)
UL
RF input SMA connectors (from Fiber Optic Modules)
Label (LEDs)
ON
ALM
DL
UL
Description
Master Point to Point Module operating status green LED:
ON when power supply is present
Point to Point Module alarm status LED:
OFF: regular operation
Blinking Orange: presence of active alarms with warning severity level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity level (2)
Red: presence of active alarms with critical severity level (1)
Fiber Optic Receiver operating status LED:
GREEN: +6dBm to -4dBm optical input power
YELLOW: warning: -4dBm to -5dBm optical input power
RED: alarm: optical input power is >+6dBm or <-5dBm
Fiber Optic Transmitter operating status LED:
BLINKING GREEN: the module is reaching its operating temperature
GREEN optical output power is available
ORANGE: warning: optical output power is degradated
RED: : Laser Fault: no optical output power
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 28
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1.4 Passive Modules providing distribution and filtering
• 4-way Combiner/Splitter Module
The 4-way Combiner/Splitter can be used to manage either up to 4 RF interface modules (POI
modules or DFE modules), operating in the same band (Multi-Operator Systems) or up to 4
Fiber Optic Transmitter/Receiver Modules.
rf interface
MODULES
(poi or dfe)
dl
4-way
splitter/combiner
dl
fiber optic
MODULE
Ul
4-way combiner (DL side) / 4-way splitter
(UL side) to manage up to 4 RF interface
modules operating in the same band
4-way
splitter/combiner
rf interface
MODULE
(poi or dfe)
fiber optic
MODULES
Ul
4-way splitter (DL side) / 4-way combiner
(UL side) to manage up to 4 Fiber Optic
Transmitter/Receiver Modules
4-way Combiner/Splitter module block diagrams
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 29
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
4-way Combiner/Splitter Module Access Points
UL COMMON
DL
DL COMMON
Up-link path output
SMA connectors (to RF
interface modules)
Up-link path input
SMA connector
Down-link path input
connectors (from RF
interface modules)
Down-link path
output
SIRIUS: Teko Telecom Modular Coverage and Capacity System
WHEN USED TO MANAGE MULTIPLE
FIBER OPTIC MODULES
UL
Description
WHEN USED TO MANAGE MULTIPLE
rf interface MODULES
Label
(Connectors)
Up-link path input
SMA connectors (from
optical sub-racks)
Up-link path output
SMA connector
Down-link
path
output connectors
(to optical sub-racks)
Down-link path input
Doc ID Number 91 080 0781 - Rel. 02
page 30
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
• Triplexer (Band Splitter/Combiner) with built-in 4-way Combiner/Splitter
The Triplexer is used in multi-band configurations to distribute signals operating in different
bands.
The module also includes a 4-way Splitter/Combiner to drive up to 4 Fiber Optic Transmitter/
Receiver Modules.
Several models of Triplexers, operating over different Uplink/Downlink frequency bands, are
available.
Example: EGSM, DCS, UMTS Triplexer with
built-in 4-way Combiner/Splitter
Example: AMPS, PCS, AWS Triplexer with built-in
4-way Combiner/Splitter
The triplexer can be used in Optical Systems to manage:
-- up to 3 RF interface modules operating in different bands and up to 4 Fiber Optic
Transmitter/Receiver Modules, or
-- up to 3 Service Front End modules operating in different bands and up to 4 Fiber Optic
Transmitter/Receiver Modules, or
-- up to 3 four-way splitter/combiner - used to manage multiple RF interface modules (up to
4 for each band) - and up to 4 Fiber Optic Transmitter/Receiver Modules.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 31
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
BAND 1
(SMR, EGSM
or AMPS)
ATT.
LOW
BAND 2
(DCS or PCS )
HIGH
DCS or
PCS
DL
(to built-in 4-way
splitter combiner)
UMTS
or AWS
BAND 3
(UMTS or AWS)
Example: EGSM, DCS, UMTS Triplexer block diagram - Downlink path
BAND 1
(SMR, EGSM
or AMPS)
ATT.
BAND 2
(DCS or PCS
AWS )
DCS or
AWS
LOW
UL
HIGH
(from built-in 4-way
splitter combiner)
UMTS
or PCS
BAND 3
(UMTS or AWS)
PCS
Example: Low band, PCS, AWS Triplexer block diagram - Uplink path
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 32
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Triplexer Module Access Points -Example
Example: EGSM, DCS, UMTS Triplexer
with built-in 4-way Combiner/Splitter
Example: AMPS, PCS, AWS Triplexer
with built-in 4-way Combiner/Splitter
DL
Up-link path input
connectors (from
optical subrack)
Down-link path
output connectors
(to optical subrack)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
WHEN USED TO MANAGE
MULTIPLE FOUR-WAY
COMBINER/SPLITTER MODULES
UL
WHEN USED TO MANAGE
MULTIPLE FIBER OPTIC
MODULES
Connectors
EU Bands US Bands Description
Low band (700 to 960MHz) input (down-link path)
EGSM
f<1GHz
Low band (700 to 960MHz) output (up-link path)
PCS
DCS or PCS input (down-link path)
DCS
AWS
DCS or AWS output (up-link path)
AWS
UMTS or AWS input (down-link path)
UMTS
PCS
UMTS or PCS output (up-link path)
Up-link path output
connectors (to 4-way
combiner/splitter
modules)
Down-link path input
connectors (from
4-way combiner/
splitter modules)
Doc ID Number 91 080 0781 - Rel. 02
page 33
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1.5 Modules for the management of the System
• Supervision Module
The Supervision Module (TSPV) allows the control and management of the entire Coverage
and Capacity System. The Supervision Module is provided with its own TCP/IP address and
with a built-in web server that allows control and management via a standard web browser.
The Coverage System can be accessed either via a physical (Ethernet LAN) connection or via
a modem connection.
Up to 9 Active Subracks can be monitored connecting a PC, either locally or remotely, to the
Ethernet port (LAN, RJ45 connector), available on the Supervision Module front panel.
Supervision Module equipped with optional built-in
wireless modem
Supervision Module with RS232 port
For remote control the System can also be accessed via optional wireless modem (integrated
inside the supervision module).
When the optional built-in wireless modem is equipped an SMA input/output connector is
available on the Supervision front panel for remote management.
When the optional built-in wireless modem is not equipped, an RS232 port is available on the
Supervision front panel for connection to an external PSTN or wireless modem
An OpenVPN application is installed on the Supervision Module to provide remote and secure
access to the System using the Internet.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 34
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
The Supervision Module can also act as an SNMP-agent providing integration into upperlevel management systems (NEM).
4 external alarms inputs and 4 dry contacts outputs are available on the Supervision module
front panel.
Please note
In order to more handily connect to EXT OUT / EXT IN dry contacts, 2x4-pole female connectors
are provided along with the Supervision Module.
2x4-pole female connector
Teko Telecom Operation and Maintenance Terminal (OMT) web pages allow the commissioning,
monitoring, setting and troubleshooting of the whole Coverage and Capacity System via a
user friendly graphical interface.
Teko Telecom OMC (Operation Management Centre) proprietary software is available to
control multiple Supervision Modules managing different Coverage and Capacity Systems in
a Network.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 35
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Supervision Module Access Points
Supervision Module equipped with
optional built-in wireless modem
Label
(Connectors)
RS485
(1 to 8)
RS485
(S1 to S4)
EXT OUT
EXT IN
RS232
ANT
LAN
Label
(LEDs)
ON
ALM
Supervision Module with RS232
connector
Description
RJ45 connectors for monitored Optical Subracks management
RJ45 connectors for remote Slave Supervision Modules
management
Dry contacts output connector
External alarms input connector
9-pole D-Sub RS232 connector for connection to an external
modem
Optional built-in modem input/output connector for remote
management
RJ45 connector Local Control Interface
Description
Supervision Module operating status green LED:
ON when power supply is present
Supervision Module alarm status LED.
OFF: regular operation
Blinking Orange: presence of active alarms with warning severity level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity level (2)
Red: presence of active alarms with critical severity level (1)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 36
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
• Alarm Board
The Alarm Board is an optional I/O Module that can be equipped in addition to the Supervision
Module, in order to increase the number of supported external alarms.
Alarm Board equipped with 16 input pins - TEA-I16
The Alarm Board allows to manage up to 16 external alarms inputs: 16 external alarms input
connectors are available on the module front panel.
The 16 Input lines are opto-isolated and are activated by a short circuit between input pins
(max current flow during short = 6mA; max Vdc at input pins = 3,3V).
On request inputs 1-to-4 can be switched to dry output contacts, normally open or closed,
depending on HW configuration.
In order to more handily connect to the dry contacts input/output connectors, four 2x4-pole
female connectors are provided along with the Alarm Board Module.
2x4-pole female connector
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 37
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Alarm Board Access Points
Alarm Board
with female dry connectors
Alarm Board
without female dry connectors
Label
Description
(Connectors)
EXT IN
External alarms input connector
EXT OUT
Optional external alarms output connector (TEA-I12O4)
Label
(LEDs)
ON
ALM
Description
Alarm Board Module operating status green LED:
ON when power supply is present
Alarm Board Module alarm status LED.
OFF: regular operation
Blinking Orange: presence of active alarms with warning severity
level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity level (2)
Red: presence of active alarms with critical severity level (1)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 38
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1.6 Power Supply Modules
• Power Supply Module
Power Supply modules are used to supply Active Subracks.
Active Subracks can be AC powered (Universal mains, 85÷264Vac, 50-60Hz) or DC powered
(-72 ÷ -36Vdc): they can be equipped with either AC or DC Power Supply modules.
AC Power Supply Module
DC Power Supply Module
The following figure shows the DC/DC Power Supply Module protection fuse position and
electrical rating. If the fuse blows, it has to be replaced.
Fuse SMD T 125V-4A
Power Supply modules can be equipped in monitored Active Subracks, in the Master Active
Subrack or in a dedicated Active Subrack.
When Power Supply modules are equipped in monitored Active Subracks, the RJ45 connector
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 39
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
available on the Power Supply Module front panel can be used for connection to the
Supervision Module, equipped in the Master Active Subrack.
Hot-plug 1+1 Redundancy feature is supported: it can be implemented to achieve high
system reliability.
Power Supply Module Access Points
AC MAINS
switch
DC switch
AC Power Supply Module
Connectors Description
RS485
AC switch
AC MAINS
Label
(LEDs)
POWER ON
ALM
RJ45 connector for RS485
connection to the Supervision
Module (monitored Subracks)
AC MAINS switch
AC MAINS socket (100-240Vac)
DC Power Supply Module
Connectors Description
RS485
DC switch
DC MAINS
RJ45 connector for RS485
connection to the Supervision
Module (monitored Subracks)
48Vdc switch
Vdc input connector (48Vdc)
Description
Power Supply Module operating status green LED:
ON when power supply is present
Power Supply Module alarm status LED.
OFF: regular operation
Blinking Orange: presence of active alarms with warning severity level
(4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity level (2)
Red: presence of active alarms with critical severity level (1)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 40
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1.7 Subracks hosting the System modules
• Active subracks
Active Subracks are provided with a backplane that allows the management and power
supply of up to 12 active modules and/or Power Supply modules.
Active subracks can be equipped with either AC or DC Power Supply modules.
The following connectors are available on each active subrack rear panel:
• one or more 28Vdc input/output connectors.
• An RJ45 connector (RS485) to be used when power supply modules are not equipped
in monitored Active Subracks. It allows connection of monitored Active Subracks to the
Supervision Module.
• A ground bolt.
28VDC ± 0.5VDC
input/output (max 10A)
RJ45 connector (RS 485)
Active Subrack with one 28Vdc input/output connector
28VDC ± 0.5VDC
outputs (max 10A each)
RJ45 connector (RS 485)
Active Subrack with three 28Vdc input/output connector
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 41
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
28VDC ± 0.5VDC
outputs (max 10A each)
RJ45 connector (RS 485)
Active Subrack provided with ten 28Vdc input/output connectors
• Passive subracks
Passive modules that do not require power nor management to function can be housed in
Passive subracks thus allowing a reduction in the cost of the whole system.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 42
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.1.8 Forced-air cooling Subrack
Teko Telecom forced-air cooling subrack is able to provide a maximum air flow of 180cfm (5m3/
min) in order to ensure the proper operation of cabinet installed equipment.
Forced-air cooling Subrack Access Points
LED
Forced-air cooling subrack - Front view
28V
;10A MAX
RS485
Forced-air cooling subrack - Rear view
Access Point
LED
RS485
28V
;10A MAX
Description
Forced-air cooling subrack general operating status LED
Green: normal operation
Blinking Orange: presence of active alarms with warning severity
level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity level (2)
Red: presence of active alarms with critical severity level (1)
RJ45 connector for RS485 connection to the Supervision Module
28VDC ± 0.5VDC input (max 10A)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 43
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.2 Coverage and Capacity Solutions
The components of SIRIUS, Teko Telecom Modular Coverage and Capacity System, can be
assembled to provide Modular Repeaters, Optical Systems and integrated solutions to improve
coverage in different environments.
1.2.1 Modular Off-air Repeaters - General description
Teko Telecom multi-band multi-operator Off-air Modular Repeaters represent the ideal
solution for cellular coverage extension, offering a cost effective alternative to dedicated BTSs
or Node Bs. They operate over different frequencies and with various frequency combinations
in the 380 to 2700MHz frequency range.
No physical connections are required between the Modular Repeaters and the cellular
network: the Digital Donor Front End Module is connected to a Donor Antenna, providing
the connection towards a BTS or Node B over an air link.
Teko Telecom Modular Off-air Repeaters can be set up by proper combination of Digital Donor
Front End Modules and Service Front End Subracks.
Service Front End Subrack
Donor Front End Modules
The Digital Donor Front End is the single-band/single-operator RF interface towards the
signal source; the Service Front End is the multi-band/single operator equipment that
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 44
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
provides wireless signal to the area to be covered.
Off-air Modular Repeaters can be equipped with one Donor Front End or more Donor Front
End modules to make multiple configurations available: single operator (single band / multiband) and multi-operator (single-band / multi-band).
A single-band single-operator Repeater can be set-up combining a Digital Donor Front End
Module and a Service Front End Subrack.
Up to 4 Digital Donor Front End Modules can be connected to a single Service Front End
obtaining a single-band 4-operator Off-air Repeater.
Digital Donor Front End Modules can be connected to different Service Front End Subracks to
provide multi-band/multi-operator Systems.
Operating principle
Modular repeaters use a directional antenna to interface with the operator’s donor BTS (or
Node B) and one or more service antennas to transmit the amplified wireless signals to the
area to be covered.
In down-link the repeater receives the signals from the BTS (or Node B), amplifies them and
re-transmits them to the mobiles. In the up-link path the repeater receives the signals from
the mobiles (MS), amplifies them and re- transmits them to the base station.
Each DFE module hosts the duplexer, to be connected to the Donor Antenna to separate/
combine Downlink and Uplink paths.
LNA
Donor
Antenna
Port
DL RF
Out
Digital Filter
DUPLEXER
PA
UL RF
In
Digital Filter
+12V +3.3V +1.8V
μP
DC/DC
FANS
RS485
28VDC
In downlink the signal from the Donor antenna is preamplified by a Low Noise Amplifier and
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 45
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
converted into an IF signal by a downconverter. The selection of the band of frequencies or
channels to be extended is handled by a digital filter.
The digital filtering can manage 1 variable band or 2 variable sub-bands.
An upconverter converts the IF signal into an RF signal.
In uplink the signal from the Service Front End Subrack is converted into an IF signal by a
downconverter, filtered and re-converted into an RF signal, amplified by a power amplifier
and re-transmitted to the signal source.
Each TSFE subrack hosts the duplexer, to be connected to a Service antenna to separate/
combine Downlink and Uplink paths.
In Downlink the signals from the Donor Front-End Modules are combined, amplified (High
Power Amplifier) and then transmitted to the area to be covered by the Service Front End
Subrack.
In Uplink, the RF signal from the Service antenna is amplified by a Low Noise Amplifier (LNA)
and split to feed up to 4 Donor Front-End Modules.
DL in1
Digital
Attenuator
DL in2
PA
From DFEs
DL in3
DL in4
4:1
Digital
Attenuator
To Optics
Service
Antenna
Port
Duplexer
DL out
UL out1
Digital
Attenuator
UL out2
LNA
To DFEs
UL out3
UL out4
4:1
+3.3V +5V
Digital
Attenuator
From Optics
μP
DC/DC
FANS
UL in
RS485
28VDC
When a single Repeater does not provide satisfactory coverage, for example when extensive
areas or long tunnels are to be covered, Modular Repeaters can be used along with a fiber fed
System (Teko Telecom Optical System).
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 46
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.2.2 Optical Systems - General Description
Teko Telecom Coverage and Capacity System components can be configured to provide a
modular multi-band multi-operator Optical System.
Optical Systems are based on the Radio over Fibre technology, which enables radio signals
transmission over optical fibres. This technology offers wide bandwidth and very little loss
along the fiber optic fibre, allowing the signals to be propagated over long distances. This
allows extensive areas coverage.
Each Teko Telecom Optical System is made up of two main parts: the Master Unit, interfacing
the signal source, and Remote Units, distributed throughout the territory to be served. Master
Unit and Remote Units are connected via single mode optical fibres (SMR 9/125).
SIGNAL SOURCE
MASTER UNIT
BTS, Node B or
Repeater
Passive POI Subracks
RF Interface
Optical Subracks
Optical Interface and Supervision
REMOTE UNITS
COAXIAL CABLE
(RF SIGNAL)
SINGLE MODE
OPTICAL FIBRE
(OPTICAL SIGNAL)
COAXIAL CABLE
RF SIGNAL
RF SIGNAL
SINGLE MODE
OPTICAL FIBRE
(OPTICAL SIGNAL)
Supervision Module
COAXIAL CABLE
(RF SIGNAL)
SINGLE MODE
OPTICAL FIBRE
(OPTICAL SIGNAL)
COAXIAL CABLE
(RF SIGNAL)
A – Master Unit
The Master Unit provides both the RF interface towards the signal source (one or more BTSs
or Node Bs) and the optical interface towards Remote Units.
MASTER UNIT
RF Interface
POI Subrack
One or more
BTSs, Node Bs or
Repeaters
RF SIGNAL
REMOTE UNITS
Optical Subrack
RF SIGNAL
Fiber Optic
Receivers
Transmitters
OPTICAL
SIGNALS
Fiber Optic
Receivers
Transmitters
RF SIGNAL
It is a rack-based modular equipment: Teko Telecom Coverage and Capacity Systems
components can be assembled in a variety of ways providing different Master Unit configuration
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 47
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
options.
Each Master Unit can be equipped with one or more RF interface subracks (subracks hosting
RF interface modules) and with one or more Optical Subracks (Active Subracks hosting Fiber
Optic Transmitter/Receiver modules).
When the Master Unit is equipped with Master and Slave Point to Point Modules, RF interface
subracks and optical subracks can be separated by a maximum distance of 20km.
• RF interface subracks
RF Interface subracks operate over different frequencies and with various frequency
combinations in the frequency range from 380 to 2700MHz.
Each RF interface subrack can be equipped with one or more RF Interface modules. Each
module interfaces to a single mobile operator / mobile standard signal source, making
multiple configurations available: single operator (single band / multi-band) and multioperator (single-band / multi-band).
Master Unit RF Interface modules can be Point of Interface (POI/TAPOI) modules and/or Donor
Front End modules.
Point of Interface modules are connected to the signal source via coaxial cable: each module
is connected to a single operator/ single standard signal source (BTS or Node B). Master Units
equipped with POI/TAPOI modules must be installed next to the donor BTS or Node B.
POI modules can be equipped in passive subracks; TAPOI modules require active subracks
(SUB-TRX).
Donor Front End modules allow the Optical System to be driven without the need of a
dedicated BTS or Node B: each Donor Front End module interfaces with a Donor Antenna
oriented towards a BTS or NodeB (connection over an air link).
Donor Front End modules require an active subrack (SUB-TRX). Each subrack can be equipped
with up to 4 Donor Front End Modules.
RF Interface subracks also host passive modules providing distribution and filtering:
• 1:4 Splitter/Combiner and
• Band Splitter/Combiner (Triplexer) with built-in 1:4 Splitter/Combiner.
Due to the flexible configuration options of Teko Telecom Coverage and Capacity Systems,
the same passive modules can be used for different purposes:
• the 4-way splitter/combiner can be used to manage: multiple RF interface modules,
operating in the same band (Multi-Operator Optical Systems) or multiple Fiber Optic
modules;
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 48
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
•
the triplexer can be used to manage
-- up to 3 RF interface modules operating in different bands and up to 4 Fiber Optic
Transmitter/Receiver Modules or
-- up to 3 Service Front End subracks operating in different bands and up to 4 Fiber Optic
Transmitter/Receiver Modules or
-- up to 3 four-way splitter/combiner - used to manage multiple RF interface modules
(up to 4 for each band) - and up to 4 Fiber Optic Transmitter/Receiver Modules.
RF Interface modules
operating in the
different bands
Band Splitter/Combiner with builtin 1:4 Splitter/Combiner used to
manage 3 RF interface modules
operating in different bands
Band Splitter/Combiner
used to manage up to 4
Fiber Optic Transmitter/
Receiver Modules
Example: active RF Interface subrack equipped with 2 POI modules and 1 DFE module operating in
different bands, Band Splitter/Combiner with built-in 1:4 Splitter/Combiner, 1:4 Splitter/Combiner
The RF Interface subracks can also be equipped with up to 4 Master Pont to Point modules for
the management of up to 4 optical subracks installed in different remote locations.
Digital Donor Front End modules can be connected to Service Front End Subracks to provide
coverage to the area adjoining the Master Unit site.
Each Service Front End can be fed by up to 4 Donor Front-End Modules interfacing the signal
source. Downlink and uplink auxiliary ports are available to drive the Optical System.
Service Front End Subrack
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 49
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
• Optical Subracks
Optical Subracks are Active Subracks hosting Fiber Optic Transmitter/Receiver modules.
Fiber Optic
Modules
Fiber Optic Transmitter/Receiver modules are the optical interface towards Remote Units:
they provide RF to optical /optical to RF conversion.
Fiber Optic modules are connected to Remote Units via single-mode optical fiber (SMR
9/125); each Fiber Optic Module can manage up to 4 Remote Units (up to 5 in cascade
configuration).
Up to 6 Fiber Optic Modules can be housed in a single Optical Subrack.
In Downlink RF signals are converted into optical signals in the Fiber Optic Transmitter modules
of the Master Unit and then they are propagated through optical fibre distribution to Remote
Units. In the Fiber Optic Receiver of each Remote Unit, the optical signal is then converted
back into an RF signal that is amplified and transmitted to mobiles through an antenna or a
passive distribution system.
In Uplink RF signal is converted into an optical signal in the Fiber Optic Transmitter of each
Remote Unit and then it is propagated via fibre optics to the Master Unit. Optical signals from
Remote Units are then converted by the Fiber Optic Receiver modules of the Master Unit into
RF signals and transmitted to the signal recipient.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 50
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Uplink and downlink optical signals are transmitted over the same single mode optical fibre
(Wavelength Division Multiplexing -WDM- technology).
The Master Optical Subrack also hosts the Supervision Module for the management of the
whole System.
When the Coverage System includes point to point links, each remote optical subrack hosts
the Slave point to point module to be connected, via optical fibre, to its Master Point to Point
module, equipped in the RF interface subracks.
The slave point to point module includes the 4-way splitter/combiner to manage up to 4 Fiber
Optic Transmitter/Receiver Modules and a built-in Supervision unit for the management of
the remote subrack and connected Remote Units.
RF INTERFACE SUBRACKS
OPTICAL SUBRACK
TO/FROM
REMOTE UNITS
MULTI-OPERATOR MULTI-STANDARD
RF INTERFACE EQUIPPED WITH
MASTER POINT TO POINT MODULES
LAYOUT
SIGNAL SOURCE
INTERFACE MODULE:
POI MODULE or
TDFE MODULE
FIBER OPTIC
TRANSMITTER
RECEIVER
MODULES
4-WAY
SPLITTER
COMBINER
INTERFACE MODULES
OPERATING IN THE
SAME BAND
SIGNAL SOURCE
INTERFACE MODULE:
POI MODULE or
TDFE MODULE
4-WAY
SPLITTER
COMBINER
TRIPLEXER
4-WAY
SPLITTER
COMBINER
INTERFACE MODULES
OPERATING IN THE
SAME BAND
SIGNAL SOURCE
REMOTE OPTICAL
SUBRACK 1
MASTER
POINT TO POINT
MODULE
POINT TO
POINT
OPTICAL LINK
INTERFACE MODULE:
POI MODULE or
TDFE MODULE
INTERFACE MODULES
OPERATING IN THE
SAME BAND
SLAVE
POINT TO POINT
MODULE
TO/FROM
REMOTE UNITS
FIBER OPTIC
TRANSMITTER
RECEIVER
MODULES
4-WAY
SPLITTER
COMBINER
MASTER
POINT TO POINT
MODULE
REMOTE OPTICAL
SUBRACK 2
TO/FROM
REMOTE UNITS
POINT TO
POINT
OPTICAL LINK
SLAVE
POINT TO POINT
MODULE
SIRIUS: Teko Telecom Modular Coverage and Capacity System
FIBER OPTIC
TRANSMITTER
RECEIVER
MODULES
Doc ID Number 91 080 0781 - Rel. 02
page 51
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Optical Subracks can be AC or DC powered. Power Supply modules can be equipped
in monitored Optical Subracks or in the Master Optical Subrack or in dedicated Active
Subracks.
Power Supply
Modules
Fiber Optic
Modules
Example of Master Optical Subrack hosting
the Supervision module, 4 Fiber Optic
Transmitter/Receiver modules, and 2 Power
Supply Modules (the second Power Supply
Module, optional, provides power supply
redundancy for higher reliability)
Supervision
Module
Power Supply
Modules
Example of Monitored Optical Subrack
equipped with 4 Fiber Optic Transmitter/
Receiver Modules and 2 Power Supply
Modules
Fiber Optic
Modules
Example of Monitored Optical Subrack
equipped with 6 Fiber Optic Transmitter/
Receiver Modules
Fiber Optic
Modules
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 52
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
B – Remote Units
Remote Units distribute wireless signals throughout the area to be covered ; they can be
installed up to 20km (12.4miles) from the Master Unit site.
Remote Units can be Single, Dual or Tri-band with different power classes: Very High, High,
Medium and Low.
Single, Dual or Tri-band Very High, High and
Medium Power Remote Unit
Single, Dual or Tri-band Low Power Remote
Unit
Remote Units are equipped with the Fiber Optic Receiver and Transmitter module (for Optical
to RF and RF to Optical conversion) power amplifiers and filtering.
A single Master Unit can drive up to 144 Remote Units. Various network structures can be
supported by the Master Unit: the Remote Units of the same Optical System can be deployed
with a point-to-point connection (star-configuration - using one fiber optic per Remote
Unit) or with cascading of up to 5 Remote Units using a single fibre and optimized optical
couplers.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 53
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
The following figure shows the Tri-band Remote Unit block diagram: in down-link the optical
signal from Master Unit is converted into an RF signal by the Fiber Optic Receiver module.
RF signals, filtered by the triplexer, are amplified by Low, Medium, High or Very High Power
amplifiers (Low, Medium, High or Very High Power Remote Units), filtered and transmitted
through an antenna or a passive distribution system.
In up-link the RF signal is filtered by the triplexer. The three RF signals are amplified by
Low-Noise Amplifiers, filtered and then converted into an optical signal by the Fiber Optic
Transmitter module. The signal is transmitted via fiber optics to the Master Unit.
PA900
Antenna
System
Fiber Optic
Receiver
From MASTER unit
(DownLink)
PA1800
PA2100
Management module
LNA900
Fiber Optic
Transmitter
To MASTER unit
(UpLink)
PSU
LNA1800
LNA2100
Example: Tri-band Remote Unit block diagram
Please Note: each final power amplifier is protected by a fuse.
Fuse 32V-7,5A HPA/MPA
Fuse 32V-20A VHPA
Very High Power/High Power/Medium Power final
amplifiers fuse position and electrical rating
Fuse 32V-7,5A
Low Power final amplifier fuse position and
electrical rating
The management module collects information relevant to the various modules. An RF modem
allows data communication over fiber between Remote Unit and Master Unit.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 54
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
•
High/Medium Power Remote Units Composition
POWER
SUPPLY
MODULES
FIBER OPTIC
MODULE
POWER AMPLIFIER
(BAND2)
POWER AMPLIFIER
(BAND3)
SUPERVISION
MODULE
CAVITY
6-PLEXER
POWER AMPLIFIER
(BAND1)
PLEASE NOTE:
The Very High/High/Medium Power Remote Unit case is equipped with a lock to guarantee
protection of the equipment. The following procedure describes how to open the
equipment.
OPENING THE REMOTE UNIT
• Unlock the cables protection using the keys delivered with the equipment
• Remove the cables protection
• Remove the Remote Unit cover, sliding it downwards
• Unscrew the 6 screws on the Remote Unit door
• Open the Remote Unit door.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 55
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Very High Power Remote Unit Composition
POWER
MODULE
SUPPLY
FIBER OPTIC
MODULE
POWER AMPLIFIER
(BAND1)
POWER AMPLIFIER
(BAND2)
POWER AMPLIFIER
(BAND3)
SUPERVISION
MODULE
CAVITY
6-PLEXER
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 56
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Low Power Remote Units can be either AC powered (Universal mains, 85÷264Vac, 50-60Hz) or
DC powered (-72 ÷ -36Vdc).
The following figure shows the DC powered Low Power DC/DC Power Supply Module
protection fuse position and electrical rating.
Fuse SMD T 125V-4A
Very High/ High and Medium power Remote Units are AC powered (Universal mains,
85÷264Vac, 50-60Hz).
The Very High Power Remote Unit Power Supply module is protected by 4 fuses. The following
figure shows the protection fuses position and electrical ratings.
F20A, 250V
F25A, 250V
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 57
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
• Remote Units External Access Points
Medium/ High and Very High Power Remote Units External Access Points
OPTICAL
DL/UL WDM
RF PORT
OPTICAL
DL/UL WDM
LED
GROUND
RF PORT
FAN
GROUND
ALARM
AC
MAINS
LED
AC
MAINS
ALARM
Fans
Medium power and Single band high power Remote Units
Bottom view
OPTICAL
DL/UL WDM
RF PORT
FAN
GROUND
LED
AC
MAINS
ALARM
Dual band/Triband high power Remote Units
Bottom view
REMOTE UNIT GENERAL OPERATING STATUS
LED description (LED)
Green: regular operation (no alarm)
Blinking Orange: presence of active alarms with
warning severity level (4)
Orange: presence of active alarms with minor
severity level (3)
Blinking Red: presence of active alarms with
major severity level (2)
Red: presence of active alarms with critical
severity level (1)
Fans
Very high power Remote Units and high power Remote Units
equipped with amplifiers operating in the LTE2600 band
Bottom view
Connectors
Description
RF PORT
OPTICAL DL/UL WDM
GROUND
AC MAINS
FAN
ALARM
Down Link/Up Link 7/16 RF connector
Optical fibres input/output connector
Equipment grounding
AC voltage input (100-240Vac)
Fans power supply and control connector
Auxiliary alarms connector (4 in, 4 out)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 58
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Low Power Remote Units External Access Points (AC Powered)
EXT
OUT
MAINS
SWITCH
EXT
IN
RS232
LED
Optical
dl/UL
RF
PORT
MAINS
SOCKET
AC MAINS
Single/Dual/Tri-Band Low Power Remote Units External Access Points
EXT
OUT
AC Mains
SWITCH
Optical
dl/UL
Vac MAINS
CONNECTOR
EXT
IN
LED
RS232
RF
PORT
Six-Band Low Power Remote Unit External Access Points
Connectors
RF PORT
OPTICAL DL/UL
AC MAINS
EXT OUT
EXT IN
RS 232
LED
Description
Down Link/Up Link RF connector (N type)
Optical fibres input/output connector
AC voltage input (100-240Vac) and switch
External alarms output connector
External alarms input connector
9-pole D-Sub RS232 connector for Local Management
Remote Unit general operating status LED
Green: no alarm
Blinking Orange: presence of active alarms with warning severity level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity level (2)
Red: presence of active alarms with critical severity level (1)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 59
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Low Power Remote Unit External Access Points (DC Powered)
Optical
dl/UL
EXT
OUT
EXT
IN
RS232
LED
48Vdc
SWITCH
RF
PORT
Vdc INPUT
CONNECTOR
Connectors
RF PORT
Description
Down Link/Up Link RF connector (N type)
OPTICAL DL/UL
Optical fibres input/output connector
48V 3A
EXT OUT
EXT IN
RS 232
Vdc input connector (48Vdc) and switch
External alarms output connector
External alarms input connector
9-pole D-Sub RS232 connector for Local Management
Remote Unit general operating status LED
Green: no alarm
Blinking Orange: presence of active alarms with warning severity
level (4)
Orange: presence of active alarms with minor severity level (3)
Blinking Red: presence of active alarms with major severity level (2)
Red: presence of active alarms with critical severity level (1)
LED
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 60
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.2.3 Coverage Systems Management and Power Supply
Management
Teko Telecom Supervision Module (TSPV) allows the management of the entire Coverage and
Capacity System.
The System Supervision Module is able to manage the Active Subrack it is equipped in (Master
Subrack) and up to other 12 Active Subracks (Monitored Subracks).
Twelve ports (1 to 8 and S1 to S4) are available on the Supervision Module front panel to be
connected to the RS485 ports of monitored Active Subracks.
The ports numbered from 1 to 8 are available for the connection to monitored subracks
mounted within the same rack hosting the Master Subrack.
The other four ports (S1 to S4) are available for the management of remote subracks equipped
with Slave supervision units.
When the Coverage System includes point to point links these ports allow the management
of the Slave Point to Point modules built-in Supervision units. Each Slave Point to Point
module Supervision unit manages the remote optical subrack - hosting the module - and all
connected Remote Units.
The Coverage System Supervision Module communicates with the Slave Point to Point builtin Supervision via the single-mode optical fiber (SMR 9/125) connecting Master and Slave
Point to Point modules.
When the Coverage System does not include point to point links, the master supervision
module communicates with the Remote Units via the single-mode optical fiber (SMR 9/125)
connecting Fiber Optic modules to Remote Units.
Address assignement
Each monitored Subrack takes its address from the Supervision Module port it is connected
to (please refer to Paragraph 2.2.2 RS485 Connections for details).
The Active Subrack equipped with the Supervision Module (Master Subrack) takes address
= 0 (zero).
The whole Coverage System can be accessed and managed simply connecting a PC, either
locally or remotely, to to the IP address of the System Supervision Module.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 61
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Example:
Optical system
management architecture:
Web interface
Communication interfaces:
Ethernet LAN,
Modem, VPN, PPP
Monitoring PC
Optical System
Supervision Module
MASTER UNIT
Passive RF
Interface
REMOTE UNITS
Optical and
Supervision
MASTER
Optical Subrack
Monitored
Optical Subrack
8th Monitored
Optical Subrack
Local management is performed connecting a PC to the Ethernet port (LAN, RJ45 connector),
available on the Supervision Module front panel. A local connection is required to perform
commissioning.
For remote control the System can be accessed via Ethernet, via external PSTN or wireless
modem or via optional built-in wireless modem.
The management of the System is performed via web pages: the Supervision Module is
equipped with a web-server and each component of the System is associated to a web page
displaying detailed information about the component.
The Supervision Module is also equipped with an SNMP-agent, which allows the control of
each parameter of the system via SNMP get/set/trap operations.
The Supervision Module is also provided with an OpenVPN application that allows remote
and secure access to the System using the Internet.
Teko Telecom Operation and Maintenance Terminal (OMT) web pages show the Coverage
System operating parameters and alarm status. They allow the commissioning, monitoring,
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 62
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
setting and troubleshooting of the whole Coverage System.
Teko Telecom Operation Management Centre (OMC) proprietary software allows the
management of multiple Teko Telecom Coverage and Capacity Systems in a Network.
OMC is a client-server application: the server collects information, such as System status
and alarms, relevant to the Systems in the Network. The Server communicates with each
System Supervision Module via Ethernet (TCP-IP socket) or via PSTN or wireless modem.
The Client provides access to the information stored in the Server database. It allows
end-users to check the status of the Coverage Systems in the Network via a user friendly
graphical interface.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 63
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
Power Supply
Coverage Systems can be AC or DC powered. Power supply modules can be equipped in
monitored Active Subracks or in the Master Subrack or in dedicated Active Subracks.
Power Supply
Modules
Example of Power Supply Modules equipped
in the Master Optical Subrack (the second
Power Supply Module, optional, provides
power supply redundancy for higher
reliability).
Fiber Optic
Modules
Supervision
Module
Power Supply
Modules
Example of Power Supply Modules equipped
in a monitored Active Subrack. The RJ45
connector available on the Power Supply
Module front panel can be used for connection
to the Supervision Module, equipped in the
Master Active Subrack.
Fiber Optic
Modules
Example of Power Supply Modules equipped
in a dedicated Active Subrack.
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 64
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
1.2.4 Teko Telecom Coverage Systems Technical Specifications
This paragraph makes Coverage and Capacity Systems mechanical, environmental and power
supply specifications available. Please refer to product datasheets for detailed electrical
specifications. Contact Teko Telecom Sales Office for further information.
•
Remote Units
Remote Unit
model
Dimensions
(HxWxD)
Weight
Operating
temperature
range
Degree of
protection
(IP)
Power supply
13 kg
(28.7 lbs)
-20°C up to +55°C
(-4°F up to +131°F)
IP32 (box)
IP66 (with
optional protection kit)
85÷264Vac
(50-60Hz) /AC
version
-72 ÷ -36Vdc
/48 version
-20°C up to +55°C
(-4°F up to +131°F)
IP66
85÷264Vac
(50-60Hz)
-20°C up to +55°C
(-4°F up to +131°F)
IP66
85÷264Vac
(50-60Hz)
-20°C up to +55°C
(-4°F up to +131°F)
IP66
85÷264Vac
(50-60Hz)
LOW POWER
Single / Dual / 350x350x100mm
Triband
(13.78x13.78x3.94 in)
max volume - heat
sinks and connectors
included
6-band
19 kg
414 x 395 x 144 mm
(24.41x16.34x10.24 in) (41.9lbs)
max volume - heat
sinks and connectors
included
MEDIUM POWER
Triband
Dual band
Single band
570x415x260mm
(22.44x16.34x10.24 in)
max volume - heat
sinks, handles and
connectors included
30 kg
(66.1 lbs)
570x415x260mm
(22.44x16.34x10.24 in)
max volume - heat
sinks, handles and
connectors included
32 kg
(70.5 lbs)
620x415x260mm
(24.41x16.34x10.24 in)
max volume - heat
sinks, handles and
connectors included
38 kg
(83.78 lbs)
28 kg
(61.73 lbs)
26 kg
(57.32 lbs)
HIGH POWER
Triband
Dual band
Single band
30 kg
(66.1 lbs)
28 kg
(61.73 lbs)
VERY HIGH POWER
Triband
Dual band
Single band
37 kg
(81.57 lbs)
36 kg
(79.37 lbs)
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 65
english
www.tekotelecom.it
Let us repeat !
www.tekotelecom.it
•
System Subracks
Dimensions
19” - 3U racks / depth 270 mm (10.63 in) - Active and Passive
Subracks
19” - 2U rack / depth 360 mm (14.17 in) - Service Front End Subrack
19” - 1U rack / depth 270 mm (10.63 in) - Forced-Air Cooling Subrack
Power supply (Active Subracks)
85÷264Vac (50-60Hz) (TPSU/AC)
-72÷-36Vdc (TPSU/48)
Operating temperature range
-5°C up to +55°C (+23°F up to +131°F) with proper forced-air cooling
SIRIUS: Teko Telecom Modular Coverage and Capacity System
Doc ID Number 91 080 0781 - Rel. 02
page 66
english

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Tagged PDF                      : No
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2011:08:05 17:09:05+02:00
Create Date                     : 2011:08:01 13:50:59+02:00
Metadata Date                   : 2011:08:05 17:09:05+02:00
Format                          : application/pdf
Document ID                     : uuid:519ecc51-65ab-4371-9076-96faa92cd775
Instance ID                     : uuid:89575e27-dd38-4b37-84d0-3345b3952eaa
Has XFA                         : No
Page Count                      : 66
Page Layout                     : SinglePage
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XM2-LOWPOWER6

Navigation menu