Teledyne Vehicle T400 Users Manual
T400 to the manual 72a687dc-2a25-4bc4-b1f2-ab4799c684c0
2015-02-03
: Teledyne Teledyne--Vehicle-T400-Users-Manual-464488 teledyne--vehicle-t400-users-manual-464488 teledyne pdf
Open the PDF directly: View PDF
Page Count: 396 [warning: Documents this large are best viewed by clicking the View PDF Link!]
- 1. INTRODUCTION, FEATURES AND OPTIONS
- 2. SPECIFICATIONS, APPROVALS & COMPLIANCE
- 3. GETTING STARTED
- 3.1. UNPACKING THE T400 ANALYZER
- 3.2. INSTRUMENT LAYOUT
- 3.3. CONNECTIONS AND SETUP
- 3.3.1. ELECTRICAL CONNECTIONS
- 3.3.1.1. Connecting Power
- 3.3.1.2. Connecting Analog Inputs (Option)
- 3.3.1.3. Connecting Analog Outputs
- 3.3.1.4. Current Loop Analog Outputs (Option 41) Setup
- 3.3.1.5. Connecting the Status Outputs
- 3.3.1.6. Connecting the Control Inputs
- 3.3.1.7. Connecting the Concentration Alarm Relay (Option 61)
- 3.3.1.8. Connecting the Communications Interfaces
- 3.3.2. PNENUMATIC CONNECTIONS
- 3.3.3. PNEUMATIC SETUPS FOR AMBIENT AIR MONITORING
- 3.3.1. ELECTRICAL CONNECTIONS
- 3.4. STARTUP, FUNCTIONAL CHECKS, AND INITIAL CALIBRATION
- 3.5. CONFIGURING THE INTERNAL ZERO/SPAN OPTION (IZS)
- 3.6. CALIBRATION VALVE OPTIONS
- 4. OVERVIEW OF OPERATING MODES
- 5. SETUP MENU
- 5.1. SETUP ( CFG: CONFIGURATION INFORMATION
- 5.2. SETUP ( DAS: INTERNAL DATA ACQUISITION SYSTEM
- 5.3. SETUP ( ACAL: AUTOMATIC CALIBRATION OPTION
- 5.4. SETUP ( RNGE: ANALOG OUTPUT REPORTING RANGE CONFIGURATION
- 5.4.1.1. Physical Range versus Analog Output Reporting Ranges
- 5.4.1.2. Analog Output Ranges for O3 Concentration
- 5.4.1.3. RNGE ( MODE ( SNGL: Single Range Mode Configuration
- 5.4.1.4. RNGE ( MODE ( DUAL: Dual Range Mode Configuration
- 5.4.1.5. RNGE ( MODE ( AUTO: Auto Range Mode Configuration
- 5.4.1.6. SETUP ( RNGE ( UNIT: Setting the Reporting Range Unit Type
- 5.5. SETUP ( PASS: PASSWORD PROTECTION
- 5.6. SETUP ( CLK: SETTING THE T400 ANALYZER’S INTERNAL TIME-OF-DAY CLOCK AND ADJUSTING SPEED
- 5.7. SETUP ( COMM: COMMUNICATIONS PORTS
- 5.8. SETUP ( VARS: VARIABLES SETUP AND DEFINITION
- 5.9. SETUP ( DIAG :DIAGNOSTICS FUNCTIONS
- 5.10. USING THE MODEL T400 ANALYZER’S ANALOG I/O
- 5.10.1. ADJUSTING & CALIBRATING THE ANALOG OUTPUT SIGNALS
- 5.10.1.1. Calibration of the Analog Outputs
- 5.10.1.2. Enabling or Disabling the AutoCal for an Individual Analog Output
- 5.10.1.3. Automatic Group Calibration of the Analog Outputs
- 5.10.1.4. Manual Calibration of the Analog Outputs Configured for Voltage Ranges
- 5.10.1.5. Manual Adjustment of Current Loop Output Span and Offset
- 5.10.1.6. Analog Output Voltage / Current Range Selection
- 5.10.1.7. Turning an Analog Output Over-Range Feature ON/OFF
- 5.10.1.8. Adding a Recorder Offset to an Analog Output
- 5.10.1.9. Selecting a Test Channel Function for Output A4
- 5.10.2. AIN CALIBRATION
- 5.10.3. CONFIGURING ANALOG INPUTS (OPTION)
- 5.10.1. ADJUSTING & CALIBRATING THE ANALOG OUTPUT SIGNALS
- 6. COMMUNICATIONS SETUP AND OPERATION
- 6.1. DATA TERMINAL/COMMUNICATION EQUIPMENT (DTE DCE)
- 6.2. COMMUNICATION MODES, BAUD RATE AND PORT TESTING
- 6.3. RS-232
- 6.4. RS-485 (OPTION)
- 6.5. ETHERNET
- 6.6. USB PORT
- 6.7. COMMUNICATIONS PROTOCOLS
- 7. DATA ACQUISITION SYSTEM (DAS) AND APICOM
- 7.1. DAS STATUS
- 7.2. DAS STRUCTURE
- 7.3. DAS CHANNELS
- 7.4. SETUP (DAS (EDIT: ACCESSING THE DAS EDIT MODE
- 7.4.1. EDITING DAS DATA CHANNEL NAMES
- 7.4.2. EDITING DAS TRIGGERING EVENTS
- 7.4.3. EDITING SAMPLE PERIOD AND REPORT PERIOD
- 7.4.4. REPORT PERIODS IN PROGRESS WHEN INSTRUMENT IS POWERED OFF
- 7.4.5. EDITING THE NUMBER OF RECORDS
- 7.4.6. RS-232 REPORT FUNCTION
- 7.4.7. ENABLING / DISABLING THE HOLDOFF FEATURE
- 7.4.8. THE COMPACT REPORT FEATURE
- 7.4.9. THE STARTING DATE FEATURE
- 7.5. DISABLING/ENABLING DATA CHANNELS
- 7.6. REMOTE DAS CONFIGURATION
- 7.7. DAS CONFIGURATION LIMITS
- 8. REMOTE OPERATION
- 9. T400 CALIBRATION PROCEDURES
- 9.1. BEFORE CALIBRATION
- 9.2. BASIC MANUAL CALIBRATION CHECKS AND CALIBRATION OF THE T400 ANALYZER
- 9.3. MANUAL CALIBRATION CHECK AND CALIBRATION WITH VALVE OPTIONS INSTALLED
- 9.4. AUTOMATIC ZERO/SPAN CAL/CHECK (AUTOCAL)
- 9.5. O3 PHOTOMETER ELECTRONIC CALIBRATION
- 9.6. CALIBRATING THE IZS OPTION O3 GENERATOR
- 10. EPA PROTOCOL CALIBRATION
- 10.1.1. T400 CALIBRATION – GENERAL GUIDELINES
- 10.1.2. CALIBRATION EQUIPMENT, SUPPLIES, AND EXPENDABLES
- 10.1.3. CALIBRATION GAS AND ZERO AIR SOURCES
- 10.1.4. RECOMMENDED STANDARDS FOR ESTABLISHING TRACEABILITY
- 10.1.5. CALIBRATION FREQUENCY
- 10.1.6. DATA RECORDING DEVICE
- 10.1.7. RECORD KEEPING
- 10.2. LEVEL 1 CALIBRATIONS VERSUS LEVEL 2 CHECKS
- 10.3. MULTIPOINT CALIBRATION
- 10.4. AUDITING PROCEDURES
- 10.5. SUMMARY OF QUALITY ASSURANCE CHECKS
- 10.6. REFERENCES
- 11. INSTRUMENT MAINTENANCE
- 11.1. MAINTENANCE SCHEDULE
- 11.2. PREDICTIVE DIAGNOSTICS
- 11.3. MAINTENANCE PROCEDURES
- 11.3.1. REPLACING THE SAMPLE PARTICULATE FILTER
- 11.3.2. REBUILDING THE SAMPLE PUMP
- 11.3.3. REPLACING THE IZS OPTION ZERO AIR SCRUBBER
- 11.3.4. IZS DESICCANT (OPTION 56)
- 11.3.5. PERFORMING LEAK CHECKS
- 11.3.6. PERFORMING A SAMPLE FLOW CHECK
- 11.3.7. MAINTENANCE OF THE PHOTOMETER ABSORPTION TUBE
- 11.3.8. ADJUSTMENT OR REPLACEMENT OF OPTIONAL IZS OZONE GENERATOR UV LAMP
- 12. TROUBLESHOOTING & SERVICE
- 12.1. GENERAL TROUBLESHOOTING
- 12.2. USING THE ANALOG OUTPUT TEST CHANNEL
- 12.3. USING THE INTERNAL ELECTRONIC STATUS LEDS
- 12.4. GAS FLOW PROBLEMS
- 12.5. CALIBRATION PROBLEMS
- 12.6. OTHER PERFORMANCE PROBLEMS
- 12.7. SUBSYSTEM CHECKOUT
- 12.8. TROUBLE SHOOTING THE PHOTOMETER
- 12.9. TROUBLE SHOOTING THE IZS OPTIONS O3 GENERATOR
- 12.10. SERVICE PROCEDURES
- 12.11. FAQ’S
- 12.12. TECHNICAL ASSISTANCE
- 13. THEORY OF OPERATION
- 13.1. MEASUREMENT METHOD
- 13.2. PNEUMATIC OPERATION
- 13.3. ELECTRONIC OPERATION
- 13.4. FRONT PANEL TOUCHSCREEN/DISPLAY INTERFACE
- 13.5. SOFTWARE OPERATION
- 14. A PRIMER ON ELECTRO-STATIC DISCHARGE
- all-appendices-assembled-nbrd.pdf
- 1. INTRODUCTION, FEATURES AND OPTIONS
- 2. SPECIFICATIONS, APPROVALS & COMPLIANCE
- 3. GETTING STARTED
- 3.1. UNPACKING THE T400 ANALYZER
- 3.2. INSTRUMENT LAYOUT
- 3.3. CONNECTIONS AND SETUP
- 3.3.1. ELECTRICAL CONNECTIONS
- 3.3.1.1. Connecting Power
- 3.3.1.2. Connecting Analog Inputs (Option)
- 3.3.1.3. Connecting Analog Outputs
- 3.3.1.4. Current Loop Analog Outputs (Option 41) Setup
- 3.3.1.5. Connecting the Status Outputs
- 3.3.1.6. Connecting the Control Inputs
- 3.3.1.7. Connecting the Concentration Alarm Relay (Option 61)
- 3.3.1.8. Connecting the Communications Interfaces
- 3.3.2. PNENUMATIC CONNECTIONS
- 3.3.3. PNEUMATIC SETUPS FOR AMBIENT AIR MONITORING
- 3.3.1. ELECTRICAL CONNECTIONS
- 3.4. STARTUP, FUNCTIONAL CHECKS, AND INITIAL CALIBRATION
- 3.5. CONFIGURING THE INTERNAL ZERO/SPAN OPTION (IZS)
- 3.6. CALIBRATION VALVE OPTIONS
- 4. OVERVIEW OF OPERATING MODES
- 5. SETUP MENU
- 5.1. SETUP ( CFG: CONFIGURATION INFORMATION
- 5.2. SETUP ( DAS: INTERNAL DATA ACQUISITION SYSTEM
- 5.3. SETUP ( ACAL: AUTOMATIC CALIBRATION OPTION
- 5.4. SETUP ( RNGE: ANALOG OUTPUT REPORTING RANGE CONFIGURATION
- 5.4.1.1. Physical Range versus Analog Output Reporting Ranges
- 5.4.1.2. Analog Output Ranges for O3 Concentration
- 5.4.1.3. RNGE ( MODE ( SNGL: Single Range Mode Configuration
- 5.4.1.4. RNGE ( MODE ( DUAL: Dual Range Mode Configuration
- 5.4.1.5. RNGE ( MODE ( AUTO: Auto Range Mode Configuration
- 5.4.1.6. SETUP ( RNGE ( UNIT: Setting the Reporting Range Unit Type
- 5.5. SETUP ( PASS: PASSWORD PROTECTION
- 5.6. SETUP ( CLK: SETTING THE T400 ANALYZER’S INTERNAL TIME-OF-DAY CLOCK AND ADJUSTING SPEED
- 5.7. SETUP ( COMM: COMMUNICATIONS PORTS
- 5.8. SETUP ( VARS: VARIABLES SETUP AND DEFINITION
- 5.9. SETUP ( DIAG :DIAGNOSTICS FUNCTIONS
- 5.10. USING THE MODEL T400 ANALYZER’S ANALOG I/O
- 5.10.1. ADJUSTING & CALIBRATING THE ANALOG OUTPUT SIGNALS
- 5.10.1.1. Calibration of the Analog Outputs
- 5.10.1.2. Enabling or Disabling the AutoCal for an Individual Analog Output
- 5.10.1.3. Automatic Group Calibration of the Analog Outputs
- 5.10.1.4. Manual Calibration of the Analog Outputs Configured for Voltage Ranges
- 5.10.1.5. Manual Adjustment of Current Loop Output Span and Offset
- 5.10.1.6. Analog Output Voltage / Current Range Selection
- 5.10.1.7. Turning an Analog Output Over-Range Feature ON/OFF
- 5.10.1.8. Adding a Recorder Offset to an Analog Output
- 5.10.1.9. Selecting a Test Channel Function for Output A4
- 5.10.2. AIN CALIBRATION
- 5.10.3. CONFIGURING ANALOG INPUTS (OPTION)
- 5.10.1. ADJUSTING & CALIBRATING THE ANALOG OUTPUT SIGNALS
- 6. COMMUNICATIONS SETUP AND OPERATION
- 6.1. DATA TERMINAL/COMMUNICATION EQUIPMENT (DTE DCE)
- 6.2. COMMUNICATION MODES, BAUD RATE AND PORT TESTING
- 6.3. RS-232
- 6.4. RS-485 (OPTION)
- 6.5. ETHERNET
- 6.6. USB PORT
- 6.7. COMMUNICATIONS PROTOCOLS
- 7. DATA ACQUISITION SYSTEM (DAS) AND APICOM
- 7.1. DAS STATUS
- 7.2. DAS STRUCTURE
- 7.3. DAS CHANNELS
- 7.4. SETUP (DAS (EDIT: ACCESSING THE DAS EDIT MODE
- 7.4.1. EDITING DAS DATA CHANNEL NAMES
- 7.4.2. EDITING DAS TRIGGERING EVENTS
- 7.4.3. EDITING SAMPLE PERIOD AND REPORT PERIOD
- 7.4.4. REPORT PERIODS IN PROGRESS WHEN INSTRUMENT IS POWERED OFF
- 7.4.5. EDITING THE NUMBER OF RECORDS
- 7.4.6. RS-232 REPORT FUNCTION
- 7.4.7. ENABLING / DISABLING THE HOLDOFF FEATURE
- 7.4.8. THE COMPACT REPORT FEATURE
- 7.4.9. THE STARTING DATE FEATURE
- 7.5. DISABLING/ENABLING DATA CHANNELS
- 7.6. REMOTE DAS CONFIGURATION
- 7.7. DAS CONFIGURATION LIMITS
- 8. REMOTE OPERATION
- 9. T400 CALIBRATION PROCEDURES
- 9.1. BEFORE CALIBRATION
- 9.2. BASIC MANUAL CALIBRATION CHECKS AND CALIBRATION OF THE T400 ANALYZER
- 9.3. MANUAL CALIBRATION CHECK AND CALIBRATION WITH VALVE OPTIONS INSTALLED
- 9.4. AUTOMATIC ZERO/SPAN CAL/CHECK (AUTOCAL)
- 9.5. O3 PHOTOMETER ELECTRONIC CALIBRATION
- 9.6. CALIBRATING THE IZS OPTION O3 GENERATOR
- 10. EPA PROTOCOL CALIBRATION
- 10.1.1. T400 CALIBRATION – GENERAL GUIDELINES
- 10.1.2. CALIBRATION EQUIPMENT, SUPPLIES, AND EXPENDABLES
- 10.1.3. CALIBRATION GAS AND ZERO AIR SOURCES
- 10.1.4. RECOMMENDED STANDARDS FOR ESTABLISHING TRACEABILITY
- 10.1.5. CALIBRATION FREQUENCY
- 10.1.6. DATA RECORDING DEVICE
- 10.1.7. RECORD KEEPING
- 10.2. LEVEL 1 CALIBRATIONS VERSUS LEVEL 2 CHECKS
- 10.3. MULTIPOINT CALIBRATION
- 10.4. AUDITING PROCEDURES
- 10.5. SUMMARY OF QUALITY ASSURANCE CHECKS
- 10.6. REFERENCES
- 11. INSTRUMENT MAINTENANCE
- 11.1. MAINTENANCE SCHEDULE
- 11.2. PREDICTIVE DIAGNOSTICS
- 11.3. MAINTENANCE PROCEDURES
- 11.3.1. REPLACING THE SAMPLE PARTICULATE FILTER
- 11.3.2. REBUILDING THE SAMPLE PUMP
- 11.3.3. REPLACING THE IZS OPTION ZERO AIR SCRUBBER
- 11.3.4. IZS DESICCANT (OPTION 56)
- 11.3.5. PERFORMING LEAK CHECKS
- 11.3.6. PERFORMING A SAMPLE FLOW CHECK
- 11.3.7. MAINTENANCE OF THE PHOTOMETER ABSORPTION TUBE
- 11.3.8. ADJUSTMENT OR REPLACEMENT OF OPTIONAL IZS OZONE GENERATOR UV LAMP
- 12. TROUBLESHOOTING & SERVICE
- 12.1. GENERAL TROUBLESHOOTING
- 12.2. USING THE ANALOG OUTPUT TEST CHANNEL
- 12.3. USING THE INTERNAL ELECTRONIC STATUS LEDS
- 12.4. GAS FLOW PROBLEMS
- 12.5. CALIBRATION PROBLEMS
- 12.6. OTHER PERFORMANCE PROBLEMS
- 12.7. SUBSYSTEM CHECKOUT
- 12.8. TROUBLE SHOOTING THE PHOTOMETER
- 12.9. TROUBLE SHOOTING THE IZS OPTIONS O3 GENERATOR
- 12.10. SERVICE PROCEDURES
- 12.11. FAQ’S
- 12.12. TECHNICAL ASSISTANCE
- 13. THEORY OF OPERATION
- 13.1. MEASUREMENT METHOD
- 13.2. PNEUMATIC OPERATION
- 13.3. ELECTRONIC OPERATION
- 13.4. FRONT PANEL TOUCHSCREEN/DISPLAY INTERFACE
- 13.5. SOFTWARE OPERATION
- 14. A PRIMER ON ELECTRO-STATIC DISCHARGE
- APPENDIX A – Software Version-Specific Documentation
- APPENDIX B - Spare Parts
- APPENDIX C - Warranty/Repair Questionnaire
- APPENDIX D – Wire List and Electronic Schematics