Televic NV CONFIDEAWCAPG3 Wireless Conference System (delegated unit) User Manual System Description

Televic NV Wireless Conference System (delegated unit) System Description

Contents

User Manual

Download: Televic NV CONFIDEAWCAPG3 Wireless Conference System (delegated unit) User Manual System Description
Mirror Download [FCC.gov]Televic NV CONFIDEAWCAPG3 Wireless Conference System (delegated unit) User Manual System Description
Document ID2676807
Application ID/dmKCnF13NCFqscAjUrK2Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize139.39kB (1742433 bits)
Date Submitted2015-07-13 00:00:00
Date Available2015-07-13 00:00:00
Creation Date2015-02-12 14:21:15
Producing SoftwareMicrosoft® Word 2013
Document Lastmod2015-02-12 14:21:15
Document TitleSystem Description
Document CreatorMicrosoft® Word 2013
Document Author: Clarysse Evelien

confidea
System Description
Attention:
This manual for Wireless Confidea System 3.0 is
valid only for all
WCAP+ firmware version
≥ 1.06
WCAP fpga version
≥ 1.06
WDU+ firmware version
≥ 1.06
WCAP+ 71.98.0033
Cocon
≥ 3.02
01
General information
Copyright Statement
Trademarks
Safety Instructions and conformity info
3.1
3.1.1
Statements for FCC and Industry Canada
3.2
Conformity and Certification info for Japan
3.3
Important safety instructions
3.4
General conformity info
10
3.5
Power Connections
10
Confidea wireless system information
4.1
FCC and ICES information
General system architecture
10
11
4.1.1
Components
11
4.1.2
Standalone system
11
Wireless network and frequency bands
12
5.1
Wireless LAN
12
5.2
Televic Confidea wireless system.
13
5.2.1
Frequency bands
13
1 Copyright Statement
No part of this publication or documentation accompanying this product may be reproduced
in any form or by any means or used to make any derivative such as translation, transformation,
or adaptation without the prior written permission of the publisher, except in case of brief
quotations embodied in critical articles or reviews. Contents are subject to change without prior
notice.
Copyright© 2008 by Televic Conference NV. All rights reserved.
The authors of this manual have made every effort in the preparation of this book to ensure
the accuracy of the information. However, the information in this manual is supplied without
warranty, either express or implied. Neither the authors, Televic Conference NV, nor its dealers
or distributors will be held liable for any damages caused or alleged to be caused either directly
or indirectly by this book.
2 Trademarks
All terms mentioned in this manual that are known to be trademarks or service marks have
been appropriately capitalized. Televic NV cannot attest to the accuracy of this information. Use
of a term in this book should not be regarded as affecting the validity of any trademark or service
mark.
Safety Instructions and conformity
info
The Confidea Wireless Conference system is state of the art and has been designed to meet
quality. Nevertheless, the individual components of the conference system can cause danger for
persons and material assets if
3.1
The conference system is not used as intended,
The conference system is set up by personnel not familiar with the safety regulations,
The conference system is converted or altered incorrectly,
The safety instructions are not observed.
FCC and ICES information
(U.S.A and Canadian Models only)
3.1.1
Statements for FCC and Industry Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
The Confidea wireless equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
3 Safety Instructions and conformity info
This Wireless discussion units and the Wireless Access Point comply with Part 15 of the FCC
Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions:
1.
This device may not cause harmful interference, and
2.
This device must accept any interference received, including interference that may
cause undesired operation.
Radiofrequency radiation exposure
Information:
This Wireless discussion units and the
Wireless Access Point comply with FCC
radiation exposure limits set forth for an
uncontrolled environment. These Wireless
discussion units and the Wireless Access Point
should be installed and operated with
minimum distance of 20 cm between the
radiator and your body.
Warning:
Changes or modifications made to this
equipment not expressly approved by
Televic NV may void the FCC
authorization to operate this equipment.
The RF-parts of the Wireless discussion units
and the Wireless Access Point must not be colocated or operating in conjunction with any
other antenna or transmitter.
3.2
Conformity and Certification info for Japan
This device has been granted a designation number by Ministry of Internal Affairs and Communications:
according:
Ordinance concerning Technical Regulations Conformity Certification etc. of Specified
Radio Equipment (特定無線設備の技術基準適合証明等に関する規則)
Article 2 clause 1 item 19/3
Approval n°:
202WW10120791/2”
202XW10120791/2
Warning:
This device should not be modified,
otherwise the granted designation
number will be invalid.
3.3
1.
Important safety instructions
Read Instructions
All the safety and operating instructions should be read before the product is operated.
2.
Retain Instructions
3.
Heed Warnings
All warnings on the product and the operating instructions should be adhered to.
4.
Follow Instructions
All instructions for installation or operating / use should be followed.
5.
Cleaning
Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Clean
only with dry cloth.
6.
Ventilation
Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and
to protect it from overheating. These openings must not be blocked or covered. The openings should never be
blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should not be placed in
a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer's
instructions have been adhered to.
7.
Heat
The product should be situated away from heat sources such as radiators, heat registers, stoves, or other
products (including amplifiers) that produce heat.
8.
Attachments
Do not use attachments not recommended by the product manufacturer as they may cause hazards.
9.
Water and Moisture
Do not use this product near water or in a moistures environment - for example, near a bath tub, wash bowl,
kitchen sink, or laundry tub; in a wet basement; or near a swimming pool, in an unprotected outdoor installation;
and the like.
10.
3 Safety Instructions and conformity info
The safety and operating instructions should be retained for future reference.
Accessories
Only use attachments/accessories specified by the manufacturer. Do not place this product on an unstable cart,
stand, tripod, bracket, or table. The product may fall, causing serious injury to a child or adult, and serious
damage to the product. Use only with a cart, stand, tripod, bracket, or table recommended by the manufacturer,
or sold with the product. Any mounting of the product should follow the manufacturer's instructions, and should
use a mounting accessory recommended by the manufacturer.
11.
Moving
A product and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces
may cause the product and cart combination to overturn.
12.
Power Sources
This product should be operated only from the type of power source indicated on the marking label. If you are
not sure of the type of power supply to your home, consult your product dealer or local power company. For
products intended to operate from battery power, or other sources, refer to the operating instructions.
13.
Power Lines
An outdoor system should not be located in the vicinity of overhead power lines or other electric light or power
circuits, or where it can fall into such power lines or circuits. When installing an outdoor system, extreme care
should be taken to keep from touching such power lines or circuits, as contact with them might be fatal. U.S.A.
models only - refer to the National Electrical Code Article 820 regarding installation of CATV systems.
14.
Grounding or Polarization
Do not defeat the safety purpose of the polarized or ground-type plug. A polarized plug has two blades with one
wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the
third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician
for replacement of the obsolete outlet.
15.
Power-Cord Protection
Power-supply cords should be routed to that they are not likely to be walked on or pinched by items placed upon
or against them, paying particular attention to cords at plug, convenience receptacles, and the point where they
exit from the product.
16.
Lightning
For added protection for this product during a lightning storm, or when it is left unattended and unused for long
periods of time, unplug it from the wall outlet. This will prevent damage to the product due to lightning and
power-line surges.
Not applicable when special functions are to be maintained, such as evacuation systems
17.
Overloading
Do not overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire
or electric shock.
18.
Object and Liquid Entry
Never push objects of any kind into this product through openings as they may touch dangerous voltage points or
short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
19.
Inflammable and Explosive Substance
Avoid using this product where there are gases, and also where there are inflammable and explosive substances
in the immediate vicinity.
20.
Heavy Shock or Vibration
When carrying this product around, do not subject the product to heavy shock or vibration.
21.
Servicing
Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous
voltage or other hazards. Refer all servicing to qualified service personnel.
22.
Damage Requiring Service
Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following
conditions:
a.
When the power-supply cord or plug is damaged.
b.
If liquid has been spilled, or objects have fallen into the product.
c.
If the product has been exposed to rain or water.
d.
If the product does not operate normally by following the operating instructions. Adjust only those
controls that are covered by the operating instructions as an improper adjustment of other controls
may result in damage and will often require extensive work by a qualified technician to restore the
product to its normal operation.
e.
If the product has been dropped or damaged in any way.
23.
When the product exhibits a distinct change in performance-this indicates a need for service.
Replacement Parts
When replacement parts are required, be sure the service technician has used replacement parts specified by the
manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fire,
electric shock, or other hazards.
24.
Safety Check
Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to
determine that the product is in proper operating condition.
25.
Coax Grounding
If an outside cable system is connected to the apparatus, be sure the cable system is grounded.
U.S.A. models only: Section 810 of the National Electrical Code, ANSI/NFPA No.70-1981, provides information
with respect to proper grounding of the mount and supporting structure, grounding of the coax to a discharge
apparatus, size of grounding conductors, location of discharge unit, connection to grounding electrodes, and
requirements for the grounding electrode.
3 Safety Instructions and conformity info
f.
3.4
General conformity info
The Confidea Wireless Conference system is compliant with following standards:



3.5
EN60065
EN55103-1/-2
IEC60914
Power Connections
For permanently connected equipment, a readily accessible disconnect device shall be incorporated in the fixed
wiring; for pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily
accessible.
Warning:
To prevent electric shock, do not use
this (polarized) plug with an extension
cord receptacle or other outlet unless
the blades can be fully inserted to
prevent blade exposure.
This label may appear on the bottom of the apparatus due to space limitations.
The lightning flash with an arrowhead symbol, with an equilateral triangle, is intended to alert
the user to the presence of un-insulated ‘dangerous voltage’ within the products enclosure that
may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation mark within an equilateral triangle is intended to alert the user to the presence
of important operating and maintenance (servicing) instructions in the literature accompanying
the appliance.
Warning:
Attention:
To reduce the risk of fire or electric
shock, do not expose this appliance
to rain or moisture. Do not open the
cabinet; refer servicing to qualified
personnel only.
Installation should be performed
by qualified service personnel only
in accordance with the National
Electrical Code or applicable local
codes.
4 Confidea wireless system information
10
4.1.1 Components
Confidea G3 is a wireless conference system offering conferencing capabilities over a robust
wireless link. Depending on the model, these facilities include discussion, voting and/or language
distribution.
The units (delegates/chairman) are table top units that make a wireless link to a Wireless
Conference Access Point called WCAP G3. This Access Point has a powerful built-in web server
that allows configuring and monitoring of the system from any PC or mobile device through a
standard internet browser.
4.1.2 Standalone system
A stand-alone Confidea wireless system offers basic discussion and voting. (Depending on the
model).
In this case there are no connections to other systems, except for the Confidea WCAP that
can be connected to a LAN network for monitoring and configuring.
The Confidea access point (WCAP) will in this set-up act as a small central unit, offering all
the functionality for a basic discussion application.
4 Confidea wireless system information
4.1 General system architecture
11
5 Wireless network and frequency
bands
5.1 Wireless LAN
Most of the wireless local area computer networks today are based on the IEEE 802.11 a/b/g
standards. These standards were developed by the IEEE (Institute of Electrical and Electronics
Engineers) in order to insure inter-operability between different WLAN vendors.
802.11
Standard
Release
Date
Frequency
(GHz)
Maximum bit
rate
(Mbits/sec)
Modulation
type
1999
54
OFDM
1999
2.4
11
DSSS
2003
2.4
54
OFDM
Note:
The 2.4GHz and 5GHz frequency bands are license free world wide.
However you must be aware of country specific limitations and follow them.
12
The wireless network of the Televic Confidea wireless system is based on the 802.11 a/g
standards.
Additional protocols have been added on top of the 802.11 a/g standards to provide high
robustness against interference from other wireless devices. These additional protocols also
ensure a guaranteed quality of service for the audio streams on the wireless network.
5.2.1 Frequency bands
The Confidea wireless system supports the following frequency bands
ISM 2.4
GHz
RLAN
low
RLAN
high
ISM 5 GHz
2412 MHz
5180 MHz
5500 MHz
5745 MHz
2417 MHz
5200 MHz
5520 MHz
5765 MHz
2422 MHz
5220 MHz
5540 MHz
5785 MHz
2427 MHz
5240 MHz
5560 MHz
5805 MHz
2432 MHz
5260 MHz
5580 MHz
5825 MHz
2437 MHz
5280 MHz
5600 MHz
2442 MHz
5300 MHz
5620 MHz
2447 MHz
5320 MHz
5640 MHz
2452 MHz
5660 MHz
2457 MHz
5680 MHz
2462 MHz
2467MHz
5700 MHz
5 Wireless network and frequency bands
5.2 Televic Confidea wireless system.
2472 MHz
13
In the 2.4 GHz ISM (Industrial Scientific Medical) band, there are 13 overlapping highfrequency carriers available. Only 3 non-overlapping carriers are available.
Europe
USA
and
Canada
Japan
Korea
2417 MHz
2422 MHz
2427 MHz
2432 MHz
2437 MHz
2442 MHz
2447 MHz
2452 MHz
2457 MHz
2462 MHz
2467MHz
ISM 2.4 GHz
2412 MHz
2472 MHz
In the
carriers
“RLAN
low”
frequency
band,
there
are
non-overlapping
Europe
USA
and
Canada
Japan
Korea
5180 MHz
5200 MHz
5220 MHz
5240 MHz
5260 MHz
5280 MHz
5300 MHz
5320 MHz
RLAN LOW
wireless
When transmitting in the 5.15-5.25 GHz band, this device is restricted to indoor use only.
14
Europe
USA
and
Canada
Japan
Korea
5500 MHz
5520 MHz
5540 MHz
5560 MHz
5580 MHz
5600 MHz
5620 MHz
5640 MHz
5660 MHz
5680 MHz
5700 MHz
RLAN HIGH
In the “5 GHz ISM” frequency band, there are 5 non-overlapping carriers. All of these carriers
can be used.
Europe
USA
and
Canada
Japan
Korea
5745 MHz
5765 MHz
5785 MHz
5805 MHz
5 GHz ISM
5 Wireless network and frequency bands
In the “RLAN high” frequency band, there are 10 non-overlapping carriers.
15
02
System Components
Wireless contribution units
16
6.1
Introduction
17
6.2
Controls and indicators
17
6.3
Installation
22
6.4
Startup and shutdown of delegate unit
22
Microphone
23
7.1
Introduction
23
7.2
Electrical and acoustic properties
23
7.3
Microphone connector
23
7.4
Operation
23
Battery pack
25
8.1
Introduction
25
8.2
Controls and indicators
25
8.3
Installation
27
Wireless Conference Access Point (WCAP)
28
9.1
Introduction
28
9.2
Installation
28
9.2.1
Wall Mounting
28
9.2.2
Tripod Mounting
28
9.3
Connections and Controls
6 Wireless contribution units
29
The wireless contribution units, called Confidea WDU, consist of Delegate and Chairman Units.
Both are used for speech reinforcement in a conference room. The chairman units are used to
guide and control an ongoing discussion.
6.2 Controls and indicators
The Confidea WDU has the following features:
1.
Microphone connector
Connection of a microphone to the wireless unit.
2.
Microphone button
Activation/deactivation of the microphone.
3.
Loudspeaker
distributes the floor channel. Mutes in case microphone is active.
4.
Headphone connectors
Connection of headphone to the wireless unit. Mono- and stereo headphones can
be used.
5.
Volume buttons
Change the volume level of the headphones.
6.
Microphone status LEDs
6 Wireless contribution units
6.1 Introduction
Indication LEDs show the status of the microphone. (Red: active, green: request)
7.
PRIOR button (Chairman Unit)
Long press: temporarily deactivates the microphone of all active units.
Short press: permanently deactivates the microphone of all active units.
8.
Next button (Chairman Unit)
Grants the floor to the next delegate in the waiting list.
9.
System volume control
Adjust system volume by holding the button and pressing the volume buttons.
10. Voting buttons
Each voting button has a blue LED indicator.
11. Voting control buttons
Used by the chairman to control a voting session. (Start / pause
/ stop)
12. Information display
Indication of voting, volume and channel information.
13. RFID card reader
14. RF Status LEDs
Blue LED Indication of the condition of the RF connection.
Off
connection established
Blinking
searching connection
On
out of range
17
15. Battery status LEDs
Red LED blinking the remaining operation time
1 Hz
4h remaining
2Hz
2h remaining
4Hz
1h remaining
Note:
Units with the out of range LED on will be switched
off after 2 minutes.
18
6 Wireless contribution units
Confidea DD G3
Confidea CD G3
19
Confidea DV
Confidea CV
20
6 Wireless contribution units
Confidea Back
21
6.3 Installation
In order to use the Confidea WDU, the battery and microphone need to be installed. For
instructions, see the microphone and battery installation and handling.
Disconnect the battery to avoid unwanted operation of the unit. Keep the devices in a clean
and dry area.
6.4 Startup and shutdown of delegate unit
To startup the delegate units simply press the microphone button for a few moments, until
the LEDs are blinking.
When units are connected to WCAP and the WCAP is switched off, the units will go to sleep
mode after +/_ 2 min, if no connection with another WCAP could be established
If the delegate units are activated they will continue to search for a connection with a WCAP,
so if no connection with a WCAP could be established, the delegate units will remain on!
To Switch off the delegate units or the WCAP needs to be deactivated to trigger automatic
sleep mode after +/_ 2 min, or batteries have to be removed
There is no switch off feature available via the delegate unit buttons
22
7.1 Introduction
The Confidea-D MIC30SL (30 cm) - D MIC40SL (40 cm) - D MIC50SL (50 cm) pluggable
microphone is used with the different delegate- and chairman units. This microphone ha a unidirectional response for optimum performance even in noisy conditions, and has a very low
susceptibility to RF-interference from mobile phones.
7 Microphone
7 Microphone
7.2 Electrical and acoustic properties
Transducer type
Back electret (condenser)
Operating principle
Pressure gradient
Polar pattern
Uni-directional,
cardioïd
Nominal impedance
Bias resistor = 1k2
Vdd = 3.3 V DC,
SPL = 1Pa
Max.SPL at 1 kHz
110 DB SPL (1% THD+N)
Signal to noise ratio
>67 dB(A)
Free field sensitivity
9.4 mV/Pa, ±3 dB @ 1 kHz or
Power supply
3.3 V DC, 0.5 mA
Consumption
0.5 mA (without LED ring);
max. 25 mA (with illuminated ring)
(-40.5 dB, 0 dB = 1 V/Pa @ 1 kHz)
7.3 Microphone connector
pin 1 : microphone GND
pin 2 : microphone signal
pin 3 : unused
pin 4 : LED +
pin 5 : LED –
7.4 Operation
The microphone contains the following elements.
23
-
Indicator ring: shows the status of the microphone
Union nut: attaches the pluggable microphone to the unit
Microphone plug: connects the microphone to the unit
The colour of the microphone indicator ring shows the status of the microphone.
24
Color
Condition
Red (on)
Microphone active
Red (flash)
Last minute of speech time (if set via
software) or Speech request (if set via
software)
Green (on)
Microphone is initialized
Green (flash)
Microphone request
8.1 Introduction
The Confidea wireless battery pack is used with the wireless conference units.
Output voltage:
7.2V
Capacity:
6600 mAh
Charge time:
4 Hours
Max charge voltage:
15V
Charge current:
2A
Autonomy:
+ 28 Hours (Typical)
8 Battery pack
8 Battery pack
8.2 Safety
25
Warning:
Danger of explosion if the battery pack is incorrectly
replaced
Replace with the same or equivalent type
Do not use or leave the battery pack at very high
temperature conditions (e.g. strong direct sunlight or a
vehicle in extremely hot conditions)
Do not throw the battery pack into fire
8.2.1 Power supply
15V / 2A
DC power plug: outer diameter: 5.5mm
Inner diameter: 2.1mm
Polarity:
8.3 Controls and indicators
The battery pack contains:
26
1.
Test button
Push to check the capacity and the status of the battery pack.
2.
Capacity and status indicator
Shows the capacity of the battery pack
3.
Clip
Locks/unlocks the battery pack in the wireless unit.
4.
Power LED
indicates that the charger is connected and powered.
5.
Charging LED
Indicates the charging status (in progress or completed) when the wall plug battery
charger is connected.
6.
Socket
to connect the charger plug.
8 Battery pack
8.4 Installation
Install a charged battery pack in a compatible device. To check the condition of the battery
pack, push the test button 1.
The indicator is a five segment LED. The first LED (LED1 closest to the test button) is red and
indicates a low capacity battery. The higher the charge, the higher the number of LEDs that light
up.
LED on
Remaining charge
LED 1 (red)
0-20%
LED 2 (orange)
20-40%
LED 3 (orange)
40-60%
LED 4 (green)
60-80%
LED 5 (green)
80-100%
After the display of the battery condition (for 4-5 seconds), the first three LEDs (LED1 to LED3)
will indicate the status of the charge circuitry.
LED 3 is flashing:
Charging circuitry is ok
All other
indications:
Indicates a failure
Disconnect the charger from
the battery pack and remove
the battery pack from the
conference unit.
27
9 Wireless Conference Access Point
(WCAP)
9.1 Introduction
All communication to and from the wireless units is controlled by the WCAP.
9.2 Installation
9.2.1 Wall Mounting
The WCAP can be mounted on the wall by means of the 2 fixing holes at the bottom side of
the device
To prevent accident, this device must be securely attached to the wall in accordance with the installation
instructions.
9.2.2 Tripod Mounting
The WCAP can also be mounted on a tripod.
28
5
7 4
2 1
1.
Power Switch
The WCAP can be switched on/off with the power switch at the back of the WCAP.
2.
Power Supply
The power supply of the WCAP is provided by a 110 - 230VAC/24VDC adaptor
3.
Digital Bus Connection
Connection with the uniCOS conference buts is done through RJ45 – connectors at
the back of the WCAP
4.
Cable retention clip
The cable retention clip is used to safeguard the cable of the power adaptor
5.
LAN port
Through the LAN connector at the back of the WCAP, a PC can be connected using
a standard cat. 5e FTP network cable.
6.
Status LEDS
The status LEDs give information on selected mode, RF link quality (Signal/Noise
Ratio) and delegate unit detection
7.
Aux input
Auxiliary balanced output connector
8.
Aux
9.
output
Auxiliary balanced input connector
9 Wireless Conference Access Point (WCAP)
9.3 Connections and Controls
29
Specifications of th ACDC adapter:
24V / 0.625A
DC power plug: outer diameter: 5.5mm
Inner diameter: 2.1mm
Polarity:
LED1
White
Blinking red
Fixed red
Blinking green
Fixed Green
LED2
LED3
Green
Off
Meaning
Boot sequence started
Unitialized golden mode
Initialized golden
Unitialized application
Initialized application
Connected with uniCOS
Connection error
Connecting with uniCOS
Standalone
Update in progress
Transmission
error/Retransmit
Packet transmit
Idle
Blinking red, green, blue
Test mode
Fixed green
Blinking red
Blinking green
Off
Blinking white
Red
Blinking red, green,
blue
Blinking red, green, blue
Remark:
At startup, the transition from boot sequence started (blinking white led) to application mode started (blinking
green) is very short and so the short red led activation in between might even not be noticed
30

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 30
Language                        : en-US
Tagged PDF                      : Yes
Title                           : System Description
Author                          : Clarysse Evelien
Subject                         : confidea
Creator                         : Microsoft® Word 2013
Create Date                     : 2015:02:12 14:21:15+01:00
Modify Date                     : 2015:02:12 14:21:15+01:00
Producer                        : Microsoft® Word 2013
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WM7CONFIDEAWCAPG3

Navigation menu