 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 1 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved UE910 3G HARDWARE USER GUIDE
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 2 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved APPLICABILITY TABLE  PRODUCTS    UE910-N3G
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 3 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved DISCLAIMER LEGAL NOTICE These Specifications are general guidelines pertaining to product selection and application and may not be appropriate for your particular project. Telit (which hereinafter shall include, its agents, licensors and affiliated companies) makes no representation as to the particular products identified in this document and makes no endorsement of any product. Telit disclaims any warranties, expressed or implied, relating to these specifications, including without limitation, warranties or merchantability, fitness for a particular purpose or satisfactory quality. Without limitation, Telit reserves the right to make changes to any products described herein and to remove any product, without notice.   It is possible that this document may contain references to, or information about Telit products, services and programs, that are not available in your region. Such references or information must not be construed to mean that Telit intends to make available such products, services and programs in your area.    USE AND INTELLECTUAL PROPERTY RIGHTS These Specifications (and the products and services contained herein) are proprietary to Telit and its licensors and constitute the intellectual property of Telit (and its licensors). All title and intellectual property rights in and to the Specifications (and the products and services contained herein) is owned exclusively by Telit and its licensors.  Other than as expressly set forth herein, no license or other rights in or to the Specifications and intellectual property rights related thereto are granted to you.   Nothing in these Specifications shall, or shall be deemed to, convey license or any other right under Telit’s patents, copyright, mask work or other intellectual property rights or the rights of others.      You may not, without the express written permission of Telit:  (i) copy, reproduce, create derivative works of, reverse engineer, disassemble, decompile, distribute, merge or modify in any manner these Specifications or the products and components described herein; (ii) separate any component part of the products described herein, or separately use any component part thereof on any equipment, machinery, hardware or system; (iii) remove or destroy any proprietary marking or legends placed upon or contained within the products or their components or these Specifications; (iv) develop methods to enable unauthorized parties to use the products or their components; and (v) attempt to reconstruct or discover any source code, underlying ideas, algorithms, file formats or programming or interoperability interfaces of the products or their components by any means whatsoever.  No part of these Specifications or any products or components described herein may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without the prior express written permission of Telit.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 4 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved HIGH RISK MATERIALS Components, units, or third-party products contained or used with the      products described herein are NOT fault-tolerant and are NOT designed, manufactured, or intended for use as on-line control equipment in the following hazardous environments requiring fail-safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems (“High Risk Activities"). Telit, its licensors and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities. TRADEMARKS You may not and may not allow others to use Telit or its third party licensors’ trademarks.  To the extent that any portion of the products, components and any accompanying documents contain proprietary and confidential notices or legends, you will not remove such notices or legends.  THIRD PARTY RIGHTS The software may include Third Party Right software. In this case you agree to comply with all terms and conditions imposed on you in respect of such separate software. In addition to Third Party Terms, the disclaimer of warranty and limitation of liability provisions in this License shall apply to the Third Party Right software.  TELIT HEREBY DISCLAIMS ANY AND ALL WARRANTIES EXPRESS OR IMPLIED FROM ANY THIRD PARTIES REGARDING ANY SEPARATE FILES, ANY THIRD PARTY MATERIALS INCLUDED IN THE SOFTWARE, ANY THIRD PARTY MATERIALS FROM WHICH THE SOFTWARE IS DERIVED (COLLECTIVELY “OTHER CODE”), AND THE USE OF ANY OR ALL THE OTHER CODE IN CONNECTION WITH THE SOFTWARE, INCLUDING (WITHOUT LIMITATION) ANY WARRANTIES OF SATISFACTORY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE.  NO THIRD PARTY LICENSORS OF OTHER CODE SHALL HAVE ANY LIABILITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOST PROFITS), HOWEVER CAUSED AND WHETHER MADE UNDER CONTRACT, TORT OR OTHER LEGAL THEORY, ARISING IN ANY WAY OUT OF THE USE OR DISTRIBUTION OF THE OTHER CODE OR THE EXERCISE OF ANY RIGHTS GRANTED UNDER EITHER OR BOTH THIS LICENSE AND THE LEGAL TERMS APPLICABLE TO ANY SEPARATE FILES, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  Copyright © Telit Communications PLC.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 5 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved CONTENTS 1 Introduction  8 1.1 Scope  8 1.2 Audience  8 1.3 Contact Information, Support  8 1.4 List of acronyms  9 1.5 Text Conventions  10 1.6. Related Documents  10 2 Overview  11 3 Pins Allocation  12 3.1 Pin-out 12  LGA Pads Layout  19 4 Power Supply  20 4.1 Power Supply Requirements  20 4.2 Power Consumption  21 4.3 General Design Rules  22  Electrical Design Guidelines  22  +5V Source Power Supply Design Guidelines  22  + 12V input Source Power Supply Design Guidelines  23  Battery Source Power Supply Design Guidelines  24  Thermal Design Guidelines  25  Power Supply PCB layout Guidelines  26 4.4 RTC Bypass out  27 4.5 VAUX Power Output  27 5 Digital Section  28 5.1 Logic Levels Specification  28 5.2 Power on  29 5.3 Power off  34 5.4 Unconditional Shutdown  36 5.5 Communication ports  39  USB 2.0 HS  39  USB HSIC  40  SPI  41  SPI Connections  41  Serial Ports  42
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 6 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  MODEM SERIAL PORT 1 (USIF0)  42  MODEM SERIAL PORT 2 (USIF1)  44  RS232 LEVEL TRANSLATION  45 5.6 General Purpose I/O  46  Using a GPIO as INPUT  47  Using a GPIO as OUTPUT  47  Indication of network service availability  48 5.7 External SIM Holder  49 5.8 ADC Converter  49 6 RF Section  50 6.1 Bands Variants  50 6.2 TX Output Power  50 6.3 RX Sensitivity  50 6.4 Antenna Requirements  51  PCB design guidelines  51  PCB Guidelines in case of FCC Certification  53  Transmission line design  53  Transmission Line Measurements  54  Antenna Installation Guidelines  56 7 Audio Section  57 7.1 Overview  57 7.2 Analog Voice Interface  57  MIC connection  58  LINE IN Connection  60  EAR Connection  61 7.3 Digital Voice Interface  62  CODEC Examples  62 8 Mechanical Design  63 8.1 Drawing  63 9 Application Design  64 9.1 Footprint  64 9.2 PCB pad design  65 9.3 PCB pad dimensions  65 9.4 Stencil  67 9.5 Solder paste  67 9.6 Solder reflow  67
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 7 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 10 Packaging  69 10.1 Tray  69 10.2 Reel  70  Carrier Tape Detail  70  Reel Detail  71  Reel Box Detail  72 10.3 Moisture sensitivity  72 11 SAFETY RECOMMANDATIONS 73 12 FCC/IC Regulatory notices  74 13 Document History  77 13.1 Revisions  77
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 8 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 1  INTRODUCTION 1.1  Scope The aim of this document is the description of some hardware solutions useful for developing a product with the Telit UE910 module.  1.2  Audience This document is intended for Telit customers, who are integrators, about to implement their applications using our UE910 modules.  1.3  Contact Information, Support For general contact, technical support services, technical questions and report documentation errors contact Telit Technical Support at: TS-EMEA@telit.com  TS-AMERICAS@telit.com  TS-APAC@telit.com   Alternatively, use: http://www.telit.com/support   For detailed information about where you can buy the Telit modules or for recommendations on accessories and components visit: http://www.telit.com   Our aim is to make this guide as helpful as possible. Keep us informed of your comments and suggestions for improvements. Telit appreciates feedback from the users of our information.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 9 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 1.4  List of acronyms Acronym Description TTSC Telit Technical Support Centre USB Universal Serial Bus HS High Speed DTE Data Terminal Equipment UMTS Universal Mobile Telecommunication System WCDMA Wideband Code Division Multiple Access HSDPA High Speed Downlink Packet Access HSUPA High Speed Uplink Packet Access UART Universal Asynchronous Receiver Transmitter HSIC High Speed Inter Chip SIM Subscriber Identification Module SPI Serial Peripheral Interface ADC Analog – Digital Converter DAC Digital – Analog Converter I/O Input Output GPIO General Purpose Input Output CMOS Complementary Metal – Oxide Semiconductor MOSI Master Output – Slave Input MISO Master Input – Slave Output CLK Clock MRDY Master Ready SRDY Slave Ready CS Chip Select RTC Real Time Clock PCB Printed Circuit Board ESR Equivalent Series Resistance VSWR Voltage Standing Wave Radio VNA Vector Network Analyzer
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 10 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  1.5  Text Conventions   Danger – This information MUST be followed or catastrophic equipment failure or bodily injury may occur.    Caution or Warning – Alerts the user to important points about integrating the module, if these points are not followed, the module and end user equipment may fail or malfunction.    Tip or Information – Provides advice and suggestions that may be useful when integrating the module.  All dates are in ISO 8601 format, i.e. YYYY-MM-DD.   1.6. Related Documents   Digital Voice Interface Application Note         80000NT10050A   SPI Port Application Note                                                                 80000NT10053A   SIM Holder Design Guides            80000NT10001a   USB HSIC Port Application Note          80000NT10071A   AT Commands Reference Guide          80378ST10091A   Telit EVK2 User Guide             1vv0300704
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 11 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 2  OVERVIEW The aim of this document is the description of some hardware solutions useful for developing a product with the Telit UE910 3G module. In this document all the basic functions of a mobile phone will be taken into account; for each one of them a proper hardware solution will be suggested and eventually the wrong solutions and common errors to be avoided will be evidenced. Obviously this document cannot embrace the whole hardware solutions and products that may be designed. The wrong solutions to be avoided shall be considered as mandatory, while the suggested hardware configurations shall not be considered mandatory, instead the information given shall be used as a guide and a starting point for properly developing your product with the Telit UE910 module. For further hardware details that may not be explained in this document refer to the Telit UE910 Product Description document where all the hardware information is reported.     NOTICE: (EN) The integration of the WCDMA UE910 cellular module within user application shall be done according to the design rules described in this manual.   (IT) L’integrazione del modulo cellulare WCDMA UE910 all’interno dell’applicazione dell’utente dovrà rispettare le indicazioni progettuali descritte in questo manuale.  (DE) Die Integration des UE910 WCDMA Mobilfunk-Moduls in ein Gerät muß gemäß der in diesem Dokument beschriebenen Kunstruktionsregeln erfolgen.  (SL) Integracija WCDMA UE910 modula v uporabniški aplikaciji bo morala upoštevati projektna navodila, opisana v tem priročniku.  (SP) La utilización del modulo WCDMA UE910 debe ser conforme a los usos para los cuales ha sido deseñado descritos en este manual del usuario.  (FR) L’intégration du module cellulaire WCDMA UE910 dans l’application de l’utilisateur sera faite selon les règles de conception décrites dans ce manuel.  (HE)   The  information  presented  in  this  document  is  believed  to  be  accurate  and  reliable.  However,  no responsibility is assumed by Telit Communications S.p.A. for its use, nor any infringement of patents or other  rights  of  third  parties  which  may  result  from  its  use.  No  license  is  granted  by  implication  or otherwise under any patent rights of Telit Communications S.p.A. other than for circuitry embodied in Telit products. This document is subject to change without notice.  UE910
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 12 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 3  PINS ALLOCATION 3.1  Pin-out Pin Signal I/O Function Type Comment USB HS 2.0 COMMUNICATION PORT B15 USB_D+ I/O USB differential Data (+) -  C15 USB_D- I/O USB differential Data (-) -  A13 VUSB I Power sense for the internal USB transceiver. -  Asynchronous Serial Port (USIF0) - Prog. / Data + HW Flow Control N15 C103/TXD I Serial data input from DTE CMOS 1.8V  M15 C104/RXD O Serial data output to DTE CMOS 1.8V  M14 C108/DTR I Input for (DTR) from DTE CMOS 1.8V  L14 C105/RTS I Input for Request to send signal (RTS) from DTE CMOS 1.8V  P15 C106/CTS O Output for Clear to Send signal (CTS) to DTE CMOS 1.8V  N14 C109/DCD O Output for  (DCD) to DTE CMOS 1.8V  P14 C107/DSR O Output for  (DSR) to DTE CMOS 1.8V  R14 C125/RING O Output for Ring (RI) to DTE CMOS 1.8V  Asynchronous Auxiliary Serial Port (USIF1) D15 TX_AUX O Auxiliary UART (TX Data to DTE) CMOS 1.8V  E15 RX_AUX I Auxiliary UART (RX Data from DTE) CMOS 1.8V  USB HSIC A12 HSIC_USB_DATA I/O USB HSIC data signal CMOS 1.2V  A11 HSIC_USB_STRB I/O USB HSIC strobe signal CMOS 1.2V  H15 HSIC_SLAVE_WAKEUP I Slave Wake Up CMOS 1.8V Shared with SPI_MRDY F15 HSIC_HOST_WAKEUP O Host Wake Up CMOS 1.8V Shared with SPI CLK K15 HSIC_SUSPEND_REQUEST O Slave Suspend Request CMOS 1.8V Shared with GPIO08  J15 HSIC_HOST_ACTIVE I Active Host Indication CMOS 1.8V Shared with SPI_SRDY SIM card interface
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 13 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved A6 SIMCLK O External SIM signal – Clock 1.8 / 3V  A7 SIMRST O External SIM signal – Reset 1.8 / 3V  A5 SIMIO I/O External SIM signal – Data I/O 1.8 / 3V  A4 SIMIN I External SIM signal – Presence (active low) CMOS 1.8  A3 SIMVCC - External SIM signal – Power supply for the SIM 1.8 / 3V  Analog Audio  B2 EAR+ O Analog Audio Interface (EAR+)   B3 EAR- O Analog Audio Interface (EAR-)   B4 MIC+ I Analog Audio Interface (MIC+)   B5 MIC- I Analog Audio Interface (MIC-)   Digital Voice Interface (DVI)  B9 DVI_WA0 I/O Digital Audio Interface (WA0) CMOS 1.8V  B6 DVI_RX I/O Digital Audio Interface (RX) CMOS 1.8V  B7 DVI_TX I/O Digital Audio Interface (TX) CMOS 1.8V  B8 DVI_CLK I/O Digital Audio Interface (CLK) CMOS 1.8V  SPI D15 SPI_MOSI I SPI MOSI CMOS 1.8V Shared with TX_AUX E15 SPI_MISO O SPI_MISO CMOS 1.8V Shared with RX_AUX F15 SPI_CLK I SPI Clock CMOS 1.8V  H15 SPI_MRDY I SPI_MRDY CMOS 1.8V  J15 SPI_SRDY O SPI_SRDY CMOS 1.8V   DIGITAL IO C8 GPIO_01 I/O GPIO_01 /STAT LED CMOS 1.8V Alternate Function STAT LED C9 GPIO_02 I/O GPIO_02 CMOS 1.8V  C10 GPIO_03 I/O GPIO_03  CMOS 1.8V  C11 GPIO_04 I/O GPIO_04 CMOS 1.8V  B14 GPIO_05 I/O GPIO_05  CMOS 1.8V  C12 GPIO_06 I/O GPIO_06 CMOS 1.8V  C13 GPIO_07 I/O GPIO_07  CMOS 1.8V  K15 GPIO_08 I/O GPIO_08 CMOS 1.8V
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 14 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved L15 GPIO_09 I/O GPIO_09 CMOS 1.8V  G15 GPIO_10 I/O GPIO_10 CMOS 1.8V  ADC B1 ADC_IN1 AI Analog / Digital converter input A/D Accepted values 0 to 1.2V DC RF SECTION K1 ANTENNA I/O WCDMA Antenna  (50 ohm) RF  Miscellaneous Functions R13 HW_SHUTDOWN* I HW Unconditional Shutdown CMOS 1.8V Active low R12 ON_OFF* I Input command for power ON CMOS 1.8V Active low C14 VRTC I VRTC Backup capacitor Power backup for the embedded RTC supply R11 VAUX/PWRMON O Supply Output for external accessories / Power ON Monitor 1.8V  Power Supply M1 VBATT - Main power supply (Baseband) Power  M2 VBATT - Main power supply (Baseband) Power  N1 VBATT_PA - Main power supply (Radio PA) Power  N2 VBATT_PA - Main power supply (Radio PA) Power  P1 VBATT_PA - Main power supply (Radio PA) Power  P2 VBATT_PA - Main power supply (Radio PA) Power  E1 GND - Ground Power  G1 GND - Ground Power  H1 GND - Ground Power  J1 GND - Ground Power  L1 GND - Ground Power  A2 GND - Ground Power  E2 GND - Ground Power  F2 GND - Ground Power  G2 GND - Ground Power  H2 GND - Ground Power  J2 GND - Ground Power  K2 GND - Ground Power
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 15 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved L2 GND - Ground Power  R2 GND - Ground Power  M3 GND - Ground Power  N3 GND - Ground Power  P3 GND - Ground Power  R3 GND - Ground Power  D4 GND - Ground Power  M4 GND - Ground Power  N4 GND - Ground Power  P4 GND - Ground Power  R4 GND - Ground Power  N5 GND - Ground Power  P5 GND - Ground Power  R5 GND - Ground Power  N6 GND - Ground Power  P6 GND - Ground Power  R6 GND - Ground Power  P8 GND - Ground Power  R8 GND - Ground Power  P9 GND - Ground Power  P10 GND - Ground Power  R10 GND - Ground Power  M12 GND - Ground Power  B13 GND - Ground Power  P13 GND - Ground Power  E14 GND - Ground Power  RESERVED C1 RESERVED - RESERVED   D1 RESERVED - RESERVED   B2 RESERVED - RESERVED   C2 RESERVED - RESERVED   D2 RESERVED - RESERVED   B3 RESERVED - RESERVED   C3 RESERVED - RESERVED   D3 RESERVED - RESERVED
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 16 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved E3 RESERVED - RESERVED   F3 RESERVED - RESERVED   G3 RESERVED - RESERVED   H3 RESERVED - RESERVED   J3 RESERVED - RESERVED   K3 RESERVED - RESERVED   L3 RESERVED - RESERVED   B4 RESERVED - RESERVED   C4 RESERVED - RESERVED   B5 RESERVED - RESERVED   C5 RESERVED - RESERVED   C6 RESERVED - RESERVED   C7 RESERVED - RESERVED   N7 RESERVED - RESERVED   P7 RESERVED - RESERVED   N8 RESERVED - RESERVED   N9 RESERVED - RESERVED   A10 RESERVED - RESERVED   N10 RESERVED - RESERVED   N11 RESERVED - RESERVED   B12 RESERVED - RESERVED   D12 RESERVED - RESERVED   N12 RESERVED - RESERVED   P12 RESERVED - RESERVED   F14 RESERVED - RESERVED   G14 RESERVED - RESERVED   H14 RESERVED - RESERVED   J14 RESERVED - RESERVED   K14 RESERVED - RESERVED   N13 RESERVED - RESERVED   L13 RESERVED - RESERVED   J13 RESERVED - RESERVED   M13 RESERVED - RESERVED   K13 RESERVED - RESERVED   H13 RESERVED - RESERVED
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 17 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved    WARNING: Reserved pins must not be connected     G13 RESERVED - RESERVED   F13 RESERVED - RESERVED   B1 RESERVED - RESERVED   B11 RESERVED - RESERVED   B10 RESERVED - RESERVED   A9 RESERVED - RESERVED   A8 RESERVED - RESERVED   D14 RESERVED - RESERVED   A14 RESERVED - RESERVED   D13 RESERVED - RESERVED   E13 RESERVED - RESERVED   F1 RESERVED - RESERVED   R9 RESERVED - RESERVED   R7 RESERVED - RESERVED   P11 RESERVED - RESERVED
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 18 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   If not used, almost all pins should be left disconnected. The only exceptions are the following pins:  PAD Signal Note M1,M2,N1,N2,P1,P2 VBATT & VBATT_PA  E1, G1, H1, J1, L1, A2, E2, F2, G2, H2 J2,K2,L2,R2,M3,N3,P3,R3,D4,M4, N4,P4,R4,N5,P5,R5,N6,P6,R6,P8, R8,P9,P10,R10,M12,B13,P13,E14 GND  R12 ON/OFF*  R13 HW_SHUTDOWN*  B15 USB_D+ If not used should be connected to a Test Point or an USB connector C15 USB_D- If not used should be connected to a Test Point or an USB connector A13 VUSB If not used should be connected to a Test Point or an USB connector N15 C103/TXD If not used should be connected to a Test Point M15 C104/RXD If not used should be connected to a Test Point L14 C105/RTS If the flow control is not used it should be connected to GND P15 C106/CTS If not used should be connected to a Test Point D15 TXD_AUX If not used should be connected to a Test Point E15 RXD_AUX If not used should be connected to a Test Point K1 MAIN ANTENNA  A6 SIMCLK  A7 SIMRST  A5 SIMIO  A4 SIMIN    RTS pin should be connected to the GND (on the module side) if flow control is not used. The above pins are also necessary to debug the application when the module is assembled on it so we recommend connecting them also to dedicated test point.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 19 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   LGA Pads Layout  TOP VIEW  A B C D E F G  H J K L M N P R    1   RES RES RES GND RES GND GND GND ANT GND VBATT VBATT_PA VBATT_PA     2 GND SPK+ RES RES GND GND GND GND GND GND GND VBATT VBATT_PA VBATT_PA GND   3 SIMVCC SPK - RES RES RES RES RES RES RES RES RES GND GND GND GND   4 SIMIN MIC+ RES GND               GND GND GND GND   5 SIMIO MIC - RES                   GND GND GND   6 SIMCLK DVI_RX RES                   GND GND GND   7 SIMRST DVI_TX RES                   RES RES RES   8 RES DVI_CLK GPIO_01                   RES GND GND   9 RES DVI_WA0 GPIO_02                   RES GND RES   10 RES RES GPIO_03                   RES GND GND   11 HSIC_USB_STRB RES GPIO_04                   RES RES VAUX/PWRMON   12 HSIC_USB_DATA RES GPIO_06 RES               GND RES RES ON_OFF*   13 VUSB GND GPIO_07 RES RES RES RES RES RES RES RES RES RES GND HW_SHUTDOWN*   14 RES GPIO_05 VRTC RES GND RES RES RES RES RES C105/RTS C108/DTR C109/DCD C107/DSR C125/RING   15   USB_D+ USB_D- TX AUX RX AUX SPI_CLK GPIO_10 SPI_MRDY SPI_SRDY GPIO_08 GPIO_09 C104/RXD C103/TXD C106/CTS
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 20 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 4  POWER SUPPLY The power supply circuitry and board layout are a very important part in the full product design and they strongly reflect on the product overall performances, hence read carefully the requirements and the guidelines that will follow for a proper design.  4.1  Power Supply Requirements The external power supply must be connected to VBATT & VBATT_PA signals and must fulfil the following requirements: Power Supply Value Nominal Supply Voltage 3.8V Normal Operating Voltage Range 3.40 V÷ 4.20 V Extended Operating Voltage Range 3.10 V÷ 4.50 V      NOTE: The Operating Voltage Range MUST never be exceeded; care must be taken when designing the application’s power supply section to avoid having an excessive voltage drop.  If the voltage drop is exceeding the limits it could cause a Power Off of the module. The Power supply must be higher than 3.22 V to power on the module  Overshoot voltage (regarding MAX Extended Operating Voltage) and drop in voltage (regarding MIN Extended Operating Voltage) MUST never be exceeded;  The “Extended Operating Voltage Range” can be used only with completely assumption and application of the HW User guide suggestions.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 21 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  4.2  Power Consumption Mode Average (mA) Mode Description Switched Off 180 uA Module supplied but switched off AT+CFUN=5 1.6 Disabled TX and RX; DRX7 WCDMA Voice 170 WCDMA voice call (TX = 10dBm) WCDMA HSDPA (22dBm) 538 WCDMA data call (Cat 8, TX = 22dBm)     NOTE: The electrical design for the Power supply should be made ensuring it will be capable of a peak current output of at least 1 A.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 22 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 4.3  General Design Rules The principal guidelines for the Power Supply Design embrace three different design steps:   the electrical design   the thermal design   the PCB layout.     Electrical Design Guidelines The electrical design of the power supply depends strongly from the power source where this power is drained. We will distinguish them into three categories:    +5V input   (typically PC internal regulator output)   +12V input (typically automotive)   Battery    +5V Source Power Supply Design Guidelines    The desired output for the power supply is 3.8V, hence there's not a big difference between the input source  and the desired output and a linear regulator can be  used. A switching power supply will not be suited because of the low drop out requirements.   When using a linear regulator, a proper heat sink shall be provided in order to dissipate the power generated.   A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks close to the Module, a 100μF capacitor is usually suited.   Make sure the low ESR capacitor on the power supply output rated at least 10V.  An example of linear regulator with 5V input is:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 23 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   + 12V input Source Power Supply Design Guidelines    The desired output for the power supply is 3.8V, hence due to the big difference between the input source and the desired output, a linear regulator is not suited and shall not be used. A switching power supply will be preferable because of its better efficiency.   When using a switching regulator, a 500kHz or more switching frequency regulator is preferable because of its smaller inductor size and its faster transient response. This allows the regulator to respond quickly to the current peaks absorption.    In any case the frequency and Switching design selection is related  to the application to be developed due to the fact the switching frequency could also generate EMC interferences.   For car PB battery the input voltage can rise up to 15,8V and this should be kept in mind when choosing components: all components in the power supply must withstand this voltage.   A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks, a 100μF capacitor is usually suited.   Make sure the low ESR capacitor on the power supply output is rated at least 10V.   For Car applications a spike protection diode should be inserted close to the power input, in order to clean the supply from spikes.    An example of switching regulator with 12V input is in the below schematic:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 24 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved     Battery Source Power Supply Design Guidelines    The desired nominal output for the power supply is 3.8V and the maximum voltage allowed is 4.2V, hence a single 3.7V Li-Ion cell battery type is suited for supplying the power to the Telit UE910 module.    A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks, a 100μF tantalum capacitor is usually suited.   Make sure the low ESR capacitor (usually a tantalum one) is rated at least 10V.   A protection diode should be inserted close to the power input, in order to save the UE910 from power polarity inversion. Otherwise the battery connector should be done in a way to avoid polarity inversions when connecting the battery.   The battery capacity must be at least 500mAh in order to withstand the current peaks of 2A; the suggested capacity is from 500mAh to 1000mAh.       WARNING: The three cells Ni/Cd or Ni/MH 3,6 V Nom. battery types or 4V PB types MUST NOT BE USED DIRECTLY since their maximum voltage can rise over the absolute maximum voltage for the UE910 and damage it.     NOTE: DON'T USE any Ni-Cd, Ni-MH, and Pb battery types directly connected with UE910. Their use can lead to overvoltage on the UE910 and damage it. USE ONLY Li-Ion battery types.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 25 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   Thermal Design Guidelines  The thermal design for the power supply heat sink should be done with the following specifications:   Average current consumption during HSDPA transmission @PWR level max :  700 mA  Average current during idle: 1.8 mA  Considering the very low current during idle, especially if Power Saving function is enabled, it is possible to consider from the thermal point of view that the device absorbs current significantly only during calls.   If we assume that the device stays into transmission for short periods of time (let's say few minutes) and then remains for a quite long time in idle (let's say one hour), then the power supply has always the time to cool down between the calls and the heat sink could be smaller than the calculated one for 700mA maximum RMS current, or even could be the simple chip package (no heat sink). Moreover in the average network conditions the device is requested to transmit at a lower power level than the maximum and hence the current consumption will be less than the 700mA, being usually around 150mA.  For these reasons the thermal design is rarely a concern and the simple ground plane where the power supply chip is placed can be enough to ensure a good thermal condition and avoid overheating.  The generated heat will be mostly conducted to the ground plane under the UE910; you must ensure that your application can dissipate it.       NOTE: The average consumption during transmissions depends on the power level at which the device is requested to transmit by the network. The average current consumption hence varies significantly.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 26 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   Power Supply PCB layout Guidelines  As seen on the electrical design guidelines the power supply shall have a low ESR capacitor on the output to cut the current peaks on the input to protect the supply from spikes The placement of this component is crucial for the correct working of the circuitry. A misplaced component can be useless or can even decrease the power supply performances.   The Bypass low ESR capacitor must be placed close to the Telit UE910 power input pads or in the case the power supply is a switching type it can be placed close to the inductor to cut the ripple provided the PCB trace from the capacitor to the UE910 is wide enough to ensure a dropless connection even during an 1A current peak.    The protection diode must be placed close to the input connector where the power source is drained.    The PCB traces from the input connector to the power regulator IC must be wide enough to ensure no voltage drops occur when an 1A current peak is absorbed.     The PCB traces to the UE910 and the Bypass capacitor must be wide enough to ensure no significant voltage drops occur. This is for the same reason as previous point. Try to keep this trace as short as possible.    To reduce the EMI due to switching, it is important to keep very small the mesh involved; thus the input capacitor, the output diode (if not embodied in the IC) and the regulator have to form a very small loop.This is done  in order  to  reduce the  radiated  field (noise)  at  the switching frequency (100-500 kHz usually).    A  dedicated  ground  for  the  Switching  regulator  separated  by  the  common  ground  plane  is suggested.    The placement of the power supply on the board should be done in such a way to guarantee that the high current return paths in the ground plane are not overlapped to any noise sensitive circuitry as the microphone amplifier/buffer or earphone amplifier.    The  power  supply input  cables should  be  kept  separate  from  noise  sensitive  lines  such as microphone/earphone cables.    The insertion of EMI filter on VBATT pins is suggested in those designs where antenna is placed close to battery or supply lines. A ferrite bead like Murata BLM18EG101TN1 or Taiyo Yuden P/N FBMH1608HM101 can be used for this purpose.  The below figure shows the recommended circuit:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 27 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 4.4  RTC Bypass out The VRTC pin brings out the Real Time Clock supply, which is separate from the rest of the digital part, allowing having only RTC going on when all the other parts of the device are off. To this power output a backup capacitor can be added in order to increase the RTC autonomy during power off of the battery. NO Devices must be powered from this pin.  In order to keep the RTC active when VBATT is not supplied it is possible to back up the RTC section connecting a backup circuit to the related VRTC signal (pad C14 on module’s Pinout).  For additional details on the Backup solutions please refer to the related application note (xE910 RTC Backup Application Note)  4.5  VAUX Power Output A regulated power supply output is provided in order to supply small devices from the module. The signal is present on Pad R11 and it is in common with the PWRMON (module powered ON indication) function. This output is always active when the module is powered ON.  The operating range characteristics of the supply are: Item Min Typical Max Output voltage 1.78V 1.80V 1.82V Output current - - 60mA Output bypass capacitor (inside the module)  1uF
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 28 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 5  DIGITAL SECTION 5.1  Logic Levels Specification  ABSOLUTE MAXIMUM RATINGS – NOT FUNCTIONAL:   OPERATING RANGE - INTERFACE LEVELS (1.8V CMOS): Parameter Min Max Input high level 1.5V 1.9V Input low level 0V 0.35V Output high level 1.6V 1.9V Output low level 0V 0.2V   OPERATING RANGE - INTERFACE LEVELS (1.2V CMOS): Parameter Min Max Input high level 0.9V 1.3V Input low level 0V 0.3V Output high level 1V 1.3V Output low level 0V 0.1V   CURRENT CHARACTERISTICS: Parameter AVG Output Current 1mA Input Current 1uA  Parameter Min Max Input level on any digital pin (CMOS 1.8) with respect to ground -0.3V 2.1V Input level on any digital pin (CMOS 1.2) with respect to ground -0.3V 1.4V
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 29 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 5.2  Power on To turn on the UE910 the pad ON_OFF* must be tied low for at least 5 seconds and then released.  The maximum current that can be drained from the ON_OFF* pad is 0,1 mA. A simple circuit to do it is:                NOTE: Don't use any pull up resistor on the ON_OFF* line, it is internally pulled up. Using pull up resistor may bring to latch up problems on the UE910 power regulator and improper power on/off of the module. The line ON_OFF* must be connected only in open collector or open drain configuration.  In this document all the lines that are inverted, hence have active low signals are labelled with a name that ends with”#",”*” or with a bar over the name.  To check if the device has powered on, the hardware line PWRMON should be monitored.  It is mandatory to avoid sending data to the serial ports during the first 200ms of the module start-up.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 30 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved A flow chart showing the proper turn on procedure is displayed below:                                           “Modem ON Proc” START VBATT > 3.22V ? ON_OFF* = LOW PWRMON=ON ? Delay = 5 sec ON_OFF* = HIGH GO TO “HW Shutdown Unconditional” PWRMON=ON ? Delay = 1 sec GO TO “Start AT Commands”” “Modem ON Proc” END N N Y Y Y N
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 31 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved A flow chart showing the AT commands managing procedure is displayed below:                       NOTE: In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the UE910 when the module is powered off or during an ON/OFF transition.     “Start AT CMD” START Delay = 300 msec Enter AT <CR> GO TO “HW Shutdown Unconditional” AT answer in 1 sec ? GO TO “Modem ON Proc.” “Start AT CMD” END Y N
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 32 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  For example: 1- Let's assume you need to drive the ON_OFF* pad with a totem pole output of a +3/5 V microcontroller (uP_OUT1):               2- Let's assume you need to drive the ON_OFF* pad directly with an ON/OFF button:              WARNING: It is recommended to set the ON_OFF* line LOW to power on the module only after VBATT is higher than 3.22V. In case this condition it is not satisfied you could use the HW_SHUTDOWN* line to recover it and then restart the power on activity using the ON_OFF * line. An example of this is described in the following diagram.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 33 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved    Power ON diagram: After HW_SHUTSDOWN* is released you could again use the ON_OFF* line to power on the module.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 34 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 5.3  Power off Turning off the device can be done in two ways:   via  AT command (see UE910 Software User Guide, AT#SHDN)  by tying low pin ON_OFF*  Either ways, the device issues a detach request to network informing that the device will not be reachable any more.  To turn OFF the UE910 the pad ON_OFF* must be tied low for at least 3 seconds and then released.      NOTE: To check if the device has been powered off, the hardware line PWRMON must be monitored. The device is powered off when PWRMON goes low.  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the UE910 when the module is powered off or during an ON/OFF transition.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 35 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  The following flow chart shows the proper turn off procedure:      “Modem OFF Proc.” START ON_OFF* = LOW PWRMON=ON? Delay >= 3 sec ON_OFF* = HIGH PWRMON=ON? GO TO “HW SHUTDOWN Unconditional” “Modem OFF Proc.” END N Y Y N OFF Mode AT#SHDN Looping for more than 15s? Y N Key AT
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 36 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 5.4  Unconditional Shutdown HW_SHUTDOWN* is used to unconditionally shutdown the UE910. Whenever this signal is pulled low, the UE910 is reset. When the device is reset it stops any operation. After the release of the line, the UE910 is unconditionally shut down, without doing any detach operation from the network where it is registered. This behaviour is not a proper shut down because any WCDMA device is requested to issue a detach request on turn off. The HW_SHUTDOWN* is internally controlled on start-up to achieve always a proper power-on reset sequence, so there's no need to control this pin on start-up.  To unconditionally shutdown the UE910, the pad HW_SHUTDOWN* must be tied low for at least 200 milliseconds and then released. The signal is internally pulled up so the pin can be left floating if not used. If used, then it must always be connected with an open collector transistor, to permit to the internal circuitry the power on reset and under voltage lockout functions.  PIN DESCRIPTION Signal Function I/O PAD HW_SHUTDOWN* Unconditional Shutdown of the Module I R13    OPERATING LEVELS Signal Status Min Max HW_SHUTDOWN* Input high 1.5V 1.9V HW_SHUTDOWN* Input Low 0V 0.35V       WARNING: The hardware unconditional Shutdown must not be used during normal operation of the device since it does not detach the device from the network. It shall be kept as an emergency exit procedure.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 37 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  A typical circuit is the following:                         For example:  Let us assume  you need to drive the HW_SHUTDOWN* pad  with  a totem pole output of a  +3/5  V microcontroller (uP_OUT2):                     NOTE: In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the UE910 when the module is powered off or during an ON/OFF transition.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 38 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   In the following flow chart is detailed the proper restart procedure:                           NOTE: Do not use any pull up resistor on the HW_SHUTDOWN* line nor any totem pole digital output. Using pull up resistor may bring to latch up problems on the UE910 power regulator and improper functioning of the module.  To proper power on again the module please refer to the related paragraph (“Power ON”) The unconditional hardware shutdown must always be implemented on the boards and should be used only as an emergency exit procedure.      “HW SHUTDOWN Unconditional” START HW_SHUTDOWN* = LOW Delay = 200ms PWRMON = ON Disconnect VBATT Y N “HW SHUTDOWN Unconditional” END HW_SHUTDOWN* = HIGH  Delay = 1s
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 39 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 5.5  Communication ports   USB 2.0 HS  The UE910 includes one integrated universal serial bus (USB 2.0 HS) transceiver. The following table is listing the available signals: PAD Signal I/O Function Type NOTE B15 USB_D+ I/O USB differential Data (+) 3.3V  C15 USB_D- I/O USB differential Data (-) 3.3V  A13 VUSB AI Power sense for the internal USB transceiver. 5V Accepted range: 4.4V to 5.25V  The USB_DPLUS and USB_DMINUS signals have a clock rate of 480 MHz.  The signal traces should be routed carefully. Trace lengths, number of vias and capacitive loading should be minimized. The characteristic impedance value should be as close as possible to 90 Ohms differential.  In case there is a need to add an ESD protection, the suggested connection is the following:               NOTE: VUSB pin should be disconnected before activating the Power Saving Mode.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 40 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   USB HSIC The UE910 Module is provided by one USB HSIC interface.   The USB HSIC (High Speed Inter Processor) Interface allows supporting the inter-processor  communication between an application processor (AP) – the host, and the modem processor  (CP) – the UE910.  The following table is listing the available signals: PAD Signal I/O Function Type NOTE A12 HSIC_USB_DATA I/O USB HSIC data signal CMOS 1.2V  A11 HSIC_USB_STRB I/O USB HSIC strobe signal CMOS 1.2V  H15 HSIC_SLAVE_WAKEUP I Slave Wake Up CMOS 1.8V Shared with SPI_MRDY F15 HSIC_HOST_WAKEUP O Host Wake Up CMOS 1.8V Shared with SPI CLK K15 HSIC_SUSPEND_REQUEST O Slave Suspend Request CMOS 1.8V Shared with GPIO08  J15 HSIC_HOST_ACTIVE I Active Host Indication CMOS 1.8V Shared with SPI_SRDY  For the detailed use of USB HSIC port please refer to the related Application Note.     NOTE: Due to the shared functions, when the USB_HSIC port is used, it is not possible to use the SPI and GPIO_08.  The USB_HSIC is not active by default but it has to be enabled using the AT#PORTCFG command (refer to the AT user guide for the detailed syntax description).
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 41 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   SPI  The UE910 Module is provided by one SPI interface.   The SPI interface defines two handshake lines for flow control and mutual wake-up of the modem and the Application Processor: SRDY (slave ready) and MRDY (master ready). The AP has the master role, that is, it supplies the clock. The following table is listing the available signals: PAD Signal I/O Function Type NOTE D15 SPI_MOSI I SPI MOSI CMOS 1.8V Shared with TX_AUX E15 SPI_MISO O SPI MISO CMOS 1.8V Shared with RX_AUX F15 SPI_CLK I SPI Clock CMOS 1.8V  H15 SPI_MRDY I SPI_MRDY CMOS 1.8V  J15 SPI_SRDY O SPI_SRDY CMOS 1.8V      NOTE: Due to the shared functions, when the SPI port is used, it is not possible to use the AUX_UART port.   SPI Connections             SPI_MISO SPI_MOSI SPI_CLK SPI_MRDY SPI_SRDY E15 D15 F15  H15 J15  UE910  AP
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 42 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   Serial Ports The UE910 module is provided with by 2 Asynchronous serial ports:   MODEM SERIAL PORT 1 (Main)   MODEM SERIAL PORT 2 (Auxiliary)  Several configurations can be designed for the serial port on the OEM hardware, but the most common are:   RS232 PC com port   microcontroller UART @ 1.8V  (Universal Asynchronous Receive Transmit)    microcontroller UART @ 5V or other voltages different from 1.8V   Depending from the type of serial port on the OEM hardware a level translator circuit may be needed to make the system work.  On the UE910 the ports are CMOS 1.8.    MODEM SERIAL PORT 1 (USIF0)  The serial port 1 on the UE910 is a +1.8V UART with all the 7 RS232 signals.  It differs from the PC-RS232 in the signal polarity (RS232 is reversed) and levels. The following table is listing the available signals: RS232 Pin Signal Pad Name Usage 1 C109/DCD N14 Data Carrier Detect Output from the UE910 that indicates the carrier presence 2 C104/RXD M15 Transmit line *see Note Output transmit line of UE910 UART 3 C103/TXD N15 Receive line *see Note Input receive of the UE910 UART 4 C108/DTR M14 Data Terminal Ready Input to the UE910 that controls the DTE READY condition 5 GND M12, B13, P13, E14 … Ground Ground 6 C107/DSR P14 Data Set Ready Output from the UE910 that indicates the module is ready 7 C106/CTS P15 Clear to Send Output  from the UE910 that controls the Hardware flow control 8 C105/RTS L14 Request to Send Input to the UE910 that controls the Hardware flow control 9 C125/RING R14 Ring Indicator Output from the UE910 that indicates the incoming call condition
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 43 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   The following table shows the typical input value of internal pull-up resistors for RTS, DTR and TXD input lines and in all module states: STATE RTS DTR TXD  Pull up tied to ON 5K to 12K 1V8 OFF Schottky diode RESET Schottky diode POWER SAVING 5K to 12K 1V8  The input line ON_OFF and HW_SHDN state can be treated as in picture below                NOTE: According to V.24, some signal names are referred to the application side, therefore on the UE910 side these signal are on the opposite direction:  TXD on the application side will be connected to the receive line (here named C103/TXD) RXD on the application side will be connected to the transmit line (here named C104/RXD)  For a minimum implementation, only the TXD, RXD lines can be connected, the other lines can be left open provided a software flow control is implemented.  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the UE910 when the module is powered off or during an ON/OFF transition.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 44 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  MODEM SERIAL PORT 2 (USIF1)  The secondary serial port  on the UE910 is a CMOS1.8V with only the RX and TX signals.  The signals of the UE910 serial port are: PAD Signal I/O Function Type NOTE D15 TX_AUX O Auxiliary UART (TX Data to DTE) CMOS 1.8V Shared with SPI_MOSI E15 RX_AUX I Auxiliary UART (RX Data from DTE) CMOS 1.8V Shared with SPI_MISO      NOTE: Due to the shared pins, when the Modem Serial port is used, it is not possible to use the SPI functions.  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the UE910 when the module is powered off or during an ON/OFF transition.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 45 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   RS232 LEVEL TRANSLATION  In  order  to  interface  the  UE910  with  a  PC  com  port  or  a  RS232  (EIA/TIA-232)  application  a  level translator is required. This level translator must:   invert the electrical signal in both directions;   Change the level from 0/1.8V to +15/-15V. Actually, the RS232 UART 16450, 16550, 16650 & 16750 chipsets accept signals with lower levels on the RS232 side (EIA/TIA-562), allowing a lower voltage-multiplying ratio on the level translator. Note that the negative signal voltage must be less than 0V and hence some sort of level translation is always required.  The simplest way to translate the levels and invert the signal is by using a single chip level translator. There are a multitude of them, differing in the number of drivers and receivers and in the levels (be sure to get a true RS232 level translator not a RS485 or other standards). By convention the driver is the level translator from the 0-1.8V UART to the RS232 level. The receiver is the translator from the RS232 level to 0-1.8V UART. In order to translate the whole set of control lines of the UART you will need:   5 drivers   3 receivers  An example of RS232 level adaptation circuitry could be done using a MAXIM transceiver (MAX218)  In this case the chipset is capable to translate directly from 1.8V to the RS232 levels (Example done on 4 signals only).                The RS232 serial port lines are usually connected to a DB9 connector with the following layout:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 46 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 5.6  General Purpose I/O The UE910 module is provided by a set of Configurable Digital Input / Output pins (CMOS 1.8V) Input pads can only be read; they report the digital value (high or low) present on the pad at the read time. Output pads can only be written or queried and set the value of the pad output. An alternate function pad is internally controlled by the UE910 firmware and acts depending on the function implemented.    The following table shows the available GPIO on the UE910: PAD Signal I/O Drive Strength Default State NOTE C8 GPIO_01 I/O 1 mA INPUT Alternate function STAT LED C9 GPIO_02 I/O 1 mA INPUT  C10 GPIO_03 I/O 1 mA INPUT  C11 GPIO_04 I/O 1 mA INPUT  B14 GPIO_05 I/O 1 mA INPUT  C12 GPIO_06 I/O 1 mA INPUT  C13 GPIO_07 I/O 1 mA INPUT  K15 GPIO_08 I/O 1 mA INPUT  L15 GPIO_09 I/O 1 mA INPUT  G15 GPIO_10 I/O 1 mA INPUT
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 47 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   Using a GPIO as INPUT The GPIO pads, when used as inputs, can be connected to a digital output of another device and report its status, provided this device has interface levels compatible with the 1.8V CMOS levels of the GPIO.  If the digital output of the device to be connected with the GPIO input pad has interface levels different from the 1.8V CMOS, then it can be buffered with an open collector transistor with a 47K pull up to 1.8V.     NOTE: In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the UE910 when the module is powered off or during an ON/OFF transition.     Using a GPIO as OUTPUT The GPIO pads, when used as outputs, can drive 1.8V CMOS digital devices or compatible hardware. When set as outputs, the pads have a push-pull output and therefore the pull-up resistor may be omitted.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 48 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  Indication of network service availability  The STAT_LED pin status shows information on the network service availability and Call status.  The function is available as alternate function of GPIO_01 (to be enabled using the AT#GPIO=1,0,2 command). In the UE910 modules, the STAT_LED needs an external transistor to drive an external LED. Therefore, the status indicated in the following table is reversed with respect to the pin status.  Device Status Led Status Device off Permanently off Not Registered Permanently on Registered in idle Blinking 1sec on + 2 sec off Registered in idle + power saving It depends on the event that triggers the wakeup (In sync with network paging) Voice Call Active Permanently on Dial-Up Blinking 1 sec on + 2 sec off  A schematic example could be:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 49 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 5.7  External SIM Holder Please refer to the related User Guide (SIM Holder Design Guides, 80000NT10001a).  5.8  ADC Converter The UE910 is provided by one AD converter. It is able to read a voltage level in the range of 0÷1.2 volts applied on the ADC pin input, store and convert it into 10 bit word.  The input line is named as ADC_IN1 and it is available on Pad B1   The following table is showing the ADC characteristics:  Item Min Typical Max Unit Input Voltage range 0 - 1.2 Volt AD conversion - - 10 bits Input Resistance 1 - - Mohm Input Capacitance  - 1 - pF   The ADC could be controlled using an AT command. The command is AT#ADC=1,2 The read value is expressed in mV  Refer to SW User Guide or AT Commands Reference Guide for the full description of this function.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 50 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 6  RF SECTION 6.1  Bands Variants The following table is listing the supported Bands:      6.2  TX Output Power      6.3  RX Sensitivity       Product Supported 3G bands UE910-N3G FDD B2, B5 Band Power Class FDD B2, B5 Class 3 (0.25W) Band Sensitivity FDD B2, B5 -111dBm
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 51 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  6.4  Antenna Requirements The antenna connection and board layout design are the most important aspect in the full product design as they strongly affect the product overall performances, hence read carefully and follow the requirements and the guidelines for a proper design. The antenna and antenna transmission line on PCB for a Telit UE910 device shall fulfil the following requirements:    PCB design guidelines When using the UE910, since there's no antenna connector on the module, the antenna must be connected to the UE910 antenna pad (K1) by means of a transmission line implemented on the PCB. In the case the antenna is not directly connected at the antenna pad of the UE910, then a PCB line is needed in order to connect with it or with its connector.  This transmission line shall fulfil the following requirements:    Item Value Frequency range Depending by frequency band(s) provided by the network operator, the customer shall use the most suitable antenna for that/those band(s) Bandwidth 70 MHz in WCDMA Band V 140 MHz in WCDMA Band II Impedance 50 ohm Input power > 24dBm Average power VSWR absolute max ≤  10:1 (limit to avoid permanent damage) VSWR recommended ≤   2:1 (limit to fulfill all regulatory requirements) Item Value Characteristic Impedance 50 ohm Max Attenuation 0,3 dB Coupling Coupling with other signals shall be avoided Ground Plane Cold End (Ground Plane) of antenna shall be equipotential to the UE910 ground pins
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 52 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved    The transmission line should be designed according to the following guidelines:   Ensure that the antenna line impedance is 50 ohm;   Keep the antenna line on the PCB as short as possible, since the antenna line loss shall be less than 0,3 dB;   Antenna line must have uniform characteristics, constant cross section; avoid meanders and abrupt curves;   Keep, if possible, one layer of the PCB used only for the Ground plane;   Surround (on the sides, over and under) the antenna line on PCB with Ground, avoid having other signal tracks facing directly the antenna line track;   The ground around the antenna line on PCB has to be strictly connected to the Ground Plane by placing vias every 2mm at least;   Place EM noisy devices as far as possible from UE910 antenna line;   Keep the antenna line far away from the UE910 power supply lines;   If you have EM noisy devices around the PCB hosting the UE910, such as fast switching ICs, take care of the shielding of the antenna line by burying it inside the layers of PCB and surround it with Ground planes, or shield it with a metal frame cover.   If you don't have EM noisy devices around the PCB of UE910, by using a micro strip on the superficial copper layer for the antenna line, the line attenuation will be lower than a buried one;  The following image is showing the suggested layout for the Antenna pad connection:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 53 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved    PCB Guidelines in case of FCC Certification In the case FCC certification is required for an application using UE910-N3G, according to FCC KDB 996369 for modular approval requirements, the transmission line has to be similar to that implemented on UE910 interface board and described in the following chapter.   Transmission line design  During the design of the UE910 interface board, the placement of components has been chosen properly, in order to keep the line length as short as possible, thus leading to lowest power losses possible. A Grounded Coplanar Waveguide (G-CPW) line has been chosen, since this kind of transmission line ensures good impedance control and can be implemented in an outer PCB layer as needed in this case. A SMA female connector has been used to feed the line. The interface board is realized on a FR4, 4-layers PCB. Substrate material is characterized by relative permittivity εr = 4.6 ± 0.4 @ 1 GHz, TanD= 0.019 ÷ 0.026 @ 1 GHz. A characteristic impedance of nearly 50 Ω is achieved using trace width = 1.1 mm, clearance from coplanar ground plane = 0.3 mm each side. The line uses reference ground plane on layer 3, while copper is removed from layer 2 underneath the line. Height of trace above ground plane is 1.335 mm. Calculated characteristic impedance is 51.6 Ω, estimated line loss is less than 0.1 dB. The line geometry is shown below:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 54 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved     Transmission Line Measurements  An HP8753E VNA (Full-2-port calibration) has been used in this measurement session.  A calibrated coaxial cable has been soldered at the pad corresponding to RF output; a SMA connector has been soldered to the board in order to characterize the losses of the transmission line including the connector itself. During Return Loss / impedance measurements, the transmission line has been terminated to 50 Ω load. Return Loss plot of line under test is shown below:                 Line input impedance (in Smith Chart format, once the line has been terminated to 50 Ω load) is shown in the following figure:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 55 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved                    Insertion Loss of G-CPW line plus SMA connector is shown below:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 56 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  Antenna Installation Guidelines  Install the antenna in a place covered by the WCDMA signal. If the device antenna is located farther than 20cm from the human body and there are no co-located transmitter then the Telit FCC/IC approvals can be re-used by the end product.  If the device antenna is located closer than 20cm from the human body or there are co-located transmitter then the additional FCC/IC testing may be required for the end product (Telit FCC/IC approvals cannot be reused). Antenna shall not be installed inside metal cases. Antenna shall be installed also according to antenna manufacturer instructions.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 57 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 7  AUDIO SECTION 7.1  Overview The UE910 is provided by two main Audio interfaces:    Analog Audio Path    Digital Audio Path     NOTE: The two Paths could not be used in parallel; If the Analog Voice lines are selected, the DVI interface is disabled and Vice versa.  7.2  Analog Voice Interface The Base Band Chip of the UE910 provides one differential input for audio to be transmitted (Uplink) and a balanced BTL output for audio to be received (downlink).  The Signals are available on the following Pads: PAD Signal I/O Function B2 EAR+ O Analog Voice Interface (EAR+) B3 EAR- O Analog Voice Interface (EAR-) B4 MIC+ I Analog Voice Interface (MIC+) B5 MIC- I Analog Voice Interface (MIC-)
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 58 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   MIC connection The bias for the microphone has to be as clean as possible; the first connection (single ended) is preferable since the Vmic noise and ground noise are fed into the input as common mode and then rejected. This sounds strange; usually the connection to use in order to reject the common mode is the balanced one. In this situation we have to recall that the microphone is a sound to current transducer, so the resistor is the current to tension transducer, so finally the resistor feeds the input in balanced way even if the configuration, from a microphone point of view, seems to be un-balanced.  The following images show some connection examples:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 59 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   If a "balanced way" is anyway desired, much more care has to be taken to Vmic noise and ground noise; also the 33pF-100Ohm-33pF RF-filter has to be doubled (one each wire).      NOTE: Since the J-FET transistor inside the microphone acts as RF-detector-amplifier, ask vendor for a microphone with anti-EMI capacitor (usually a 33pF or a 10pF capacitor placed across the output terminals inside the case).
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 60 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved    LINE IN Connection  If the audio source is not a mike but a different device, the following connections can be done. Place 100nF capacitor in series with both inputs, so the DC current is blocked. Place the 33pF-100Ohm-33pF RF-filter, in order to prevent some EMI field to get into the high impedance high gain MIC inputs. Since the input is differential, the common mode voltage noise between the two (different) ground is rejected, provided that both MIC+ & MIC- are connected directly onto the source.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 61 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved    EAR Connection The audio output of the UE910 is balanced, this is helpful to double the level and to reject common mode (click and pop are common mode and therefore rejected). These outputs can drive directly a small loudspeaker with electrical impedance not lower than 16 Ohm.                       NOTE: In order to get the maximum audio level at a given output voltage level (dBspl/Vrms), the following breaking through procedure can be used. Have the loudspeaker as close as you can to the listener (this simplify also the echo cancelling); choose the loudspeaker with the higher sensitivity (dBspl per W); choose loudspeakers with the impedance close to the limit, in order to feed more power inside the transducer (it increases the W/Vrms ratio). If this were not enough, an external amplifier should be used.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 62 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 7.3  Digital Voice Interface The UE910 Module is provided by one DVI digital voice interface. The Signals are available on the following Pads: PAD Signal I/O Function B9 DVI_WA0 I/O Digital Voice Interface (Word Alignment / LRCLK) B6 DVI_RX I Digital Voice Interface (RX) B7 DVI_TX O Digital Voice Interface (TX) B8 DVI_CLK I/O Digital Voice Interface (BCLK)    CODEC Examples Please refer to the Digital Audio Application note.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 63 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 8  MECHANICAL DESIGN 8.1  Drawing  Dimensions in mm PIN B1 Lead Free Alloy: Surface Finishing Ni/Au for all solder pads
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 64 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 9  APPLICATION DESIGN  The UE910 modules have been designed in order to be compliant with a standard lead-free SMT process. 9.1  Footprint TOP VIEW                       In order to easily rework the UE910 is suggested to consider on the application a 1.5 mm placement inhibit area around the module. It is also suggested, as common rule for an SMT component, to avoid having a mechanical part of the application in direct contact with the module.    NOTE: In the customer application, the region under WIRING INHIBIT (see figure above) must be clear from signal or ground paths.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 65 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  9.2  PCB pad design Non solder mask defined (NSMD) type is recommended for the solder pads on the PCB.                    9.3  PCB pad dimensions The recommendation for the PCB pads dimensions are described in the following image (dimensions in mm)                                   Solder resist openings PCB Copper PadSolder Mask SMD (Solder Mask Defined) NSMD (Non Solder Mask Defined)
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 66 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   It is not recommended to place via or micro-via not covered by solder resist in an area of 0,3 mm around the pads unless it carries the same signal of the pad itself             (see following figure).                         Holes in pad are allowed only for blind holes and not for through holes.  Recommendations for PCB pad surfaces: Finish Layer Thickness (um) Properties Electro-less Ni / Immersion Au 3 –7 / 0.05 – 0.15 good solder ability protection, high shear force values   The PCB must be able to resist the higher temperatures which are occurring at the lead-free process. This issue should be discussed with the PCB-supplier. Generally, the wettability of tin-lead solder paste on the described surface plating is better compared to lead-free solder paste. It is not necessary to panel the application’s PCB, however in that case it is suggested to use milled contours and predrilled board breakouts; scoring or v-cut solutions are not recommended.      Inhibit area for micro-via
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 67 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  9.4  Stencil Stencil’s apertures layout can be the same of the recommended footprint (1:1), we suggest a thickness of stencil foil ≥ 120 µm.   9.5  Solder paste Item Lead Free Solder Paste Sn/Ag/Cu  We recommend using only “no clean” solder paste in order to avoid the cleaning of the modules after assembly.  9.6  Solder reflow Recommended solder reflow profile:
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 68 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved  Profile Feature Pb-Free Assembly Average ramp-up rate (TL to TP) 3°C/second max Preheat – Temperature Min (Tsmin) – Temperature Max (Tsmax) – Time (min to max) (ts)  150°C 200°C 60-180 seconds Tsmax to TL – Ramp-up Rate  3°C/second max Time maintained above: – Temperature (TL) – Time (tL)  217°C 60-150 seconds Peak Temperature (Tp) 245 +0/-5°C Time within 5°C of actual Peak Temperature (tp) 10-30 seconds  Ramp-down Rate 6°C/second max. Time 25°C to Peak Temperature 8 minutes max.     NOTE: All temperatures refer to topside of the package, measured on the package body surface     WARNING: The UE910 module withstands one reflow process only.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 69 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 10  PACKAGING 10.1  Tray The UE910 modules are packaged on trays of 36 pieces each. These trays can be used in SMT processes for pick & place handling.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 70 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 10.2  Reel The UE910 can be packaged on reels of 200 pieces each.  See figure for module positioning into the carrier.     Carrier Tape Detail
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 71 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   Reel Detail
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 72 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   Reel Box Detail    10.3  Moisture sensitivity   The UE910 is a Moisture Sensitive Device level 3, in according with standard IPC/JEDEC J-STD-020, take care all the relatives requirements for using this kind of components. Moreover, the customer has to take care of the following conditions: a) Calculated shelf life in sealed bag: 12 months at <40°C and <90% relative humidity (RH). b) Environmental condition during the production: 30°C / 60% RH according to IPC/JEDEC J-STD-033A paragraph 5. c) The maximum time between the opening of the sealed bag and the reflow process must be 168 hours if condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected d) Baking is required if conditions b) or c) are not respected e) Baking is required if the humidity indicator inside the bag indicates 10% RH or more
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 73 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 11 SAFETY RECOMMANDATIONS READ CAREFULLY Be sure the use of this product is allowed in the country and in the environment required. The use of this product may be dangerous and has to be avoided in the following areas: Where it can interfere with other electronic devices in environments such as hospitals, airports, aircrafts, etc Where there is risk of explosion such as gasoline stations, oil refineries, etc  It is responsibility of the user to enforce the country regulation and the specific environment regulation.  Do not disassemble the product; any mark of tampering will compromise the warranty validity. We recommend following the instructions of the hardware user guides for a correct wiring of the product. The product has to be supplied with a stabilized voltage source and the wiring has to be conforming to the security and fire prevention regulations. The product has to be handled with care, avoiding any contact with the pins because electrostatic discharges may damage the product itself. Same cautions have to be taken for the SIM, checking carefully the instruction for its use. Do not insert or remove the SIM when the product is in power saving mode. The system integrator is responsible of the functioning of the final product; therefore, care has to be taken to the external components of the module, as well as of any project or installation issue, because the risk of disturbing the GSM network or external devices or having impact on the security. Should there be any doubt, please refer to the technical documentation and the regulations in force.  Every module has to be equipped with a proper antenna with specific characteristics. The antenna has to be installed with care in order to avoid any interference with other electronic devices and has to guarantee a minimum distance from the body (20 cm). In case of this requirement cannot be satisfied, the system integrator has to assess the final product against the SAR regulation.  The European Community provides some Directives for the electronic equipments introduced on the market. All the relevant information’s are available on the European Community website: http://europa.eu.int/comm/enterprise/rtte/dir99-5.htm    The text of the Directive 99/05 regarding telecommunication equipments is available, while the applicable Directives (Low Voltage and EMC) are available at: http://europa.eu.int/comm/enterprise/electr_equipment/index_en.htm
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 74 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 12  FCC/IC REGULATORY NOTICES Modification statement Telit has not approved any changes or modifications to this device by the user. Any changes or modifications could void the user’s authority to operate the equipment.  Telit n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit la nature. Tout changement ou modification peuvent annuler le droit d’utilisation de l’appareil par l’utilisateur.  Interference statement This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.  Wireless notice This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. The antenna should be installed and operated with minimum distance of 20 cm between the radiator and your body. Antenna gain must be below: Frequency Band Gain Band II (1900 MHz) 9.01 dBi Band V (850 MHz) 7.76 dBd   This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 75 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   Cet appareil est conforme aux limites d'exposition aux rayonnements de la IC pour un environnement non contrôlé. L'antenne doit être installé de façon à garder une distance minimale de 20 centimètres entre la source de rayonnements et votre corps. Gain de l'antenne doit être ci-dessous: Bande de fréquence Gain Band II (1900 MHz) 9.01 dBi Band V (850 MHz) 7.76 dBd  L'émetteur ne doit pas être colocalisé ni fonctionner conjointement avec à autre antenne ou autre émetteur.  FCC Class B digital device notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.  Labelling Requirements for the Host device The host device shall be properly labelled to identify the modules within the host device. The certification label of the module shall be clearly visible at all times when installed in the host device, otherwise the host device must be labelled to display the FCC ID and IC of the module, preceded by the words "Contains transmitter module", or the word "Contains", or similar wording expressing the same meaning, as follows:  Contains FCC ID: RI7UE910N3 Contains IC: 5131A-UE910N3
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 76 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved   L'appareil hôte doit être étiqueté comme il faut pour permettre l'identification des modules qui s'y trouvent. L'étiquette de certification du module donné doit être posée sur l'appareil hôte à un endroit bien en vue en tout temps. En l'absence d'étiquette, l'appareil hôte doit porter une étiquette donnant le FCC ID et le IC du module, précédé des mots « Contient un module d'émission », du mot « Contient » ou d'une formulation similaire exprimant le même sens, comme suit :  Contains FCC ID: RI7UE910N3 Contains IC: 5131A-UE910N3   CAN ICES-3 (B) / NMB-3 (B) This Class B digital apparatus complies with Canadian ICES-003.  Cet appareil numérique de classe B est conforme à la norme canadienne ICES-003.
 UE910 3G HARDWARE USER GUIDE 1vv0301171 Rev.3 • 2015-04-17 77 of 78 Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved 13  DOCUMENT HISTORY 13.1  Revisions Revision Date Changes 0 2014-10-01 Preliminary Version 1 2015-01-08 Updated document format 2 2015-03-31 Added RX Sensitivity Added Third Party Rights Added FCC/IC Regulatory Notices Safety Recommendations Updated Tray Packaging Updated Chapter 4.2 3 2015-04-17 Updated Chapter 12

Navigation menu