 MBS USER AND INSTALLATION MANUAL  01.01.00/1 Rev.1 PRODUCT:  MBS CODE:  D148X01_DDS06 VERSION:  01  REVISION:  00  DATE:  05/10/11 CLASSIFICATION:  General information   Internal document   DOCUMENT MAINTENANCE THIS DOCUMENT HAS 17 PAGES EDIT.  DATE  AUTHOR  DESCRIPTION 1.0 05/10/11  Javier Córdova  First edition.                                                     DOCUMENT APPROVAL ACTIVITY  NAME  DATE  SIGNATURE Prepared      Revised Project Manager      Approved R&D Director
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 2 of 38  01.01.00/1 Rev.1  PowerTrunk Inc. is the subsidiary of Teltronic S.A.U. responsible for business development, distribution and customer support for Teltronic’s Land Mobile Radio products in North America. The company is headquartered in New York City. Teltronic S.A.U. distributes the same products for Land Mobile Radio under different trademarks and brand names in other regions of the world.    Disclaimer   Although every reasonable effort has been made to ensure the accuracy of the information contained herein and any other referred document, this should not be construed as a commitment on the part of Teltronic S.A.U. and/or PowerTrunk Inc., and the liability of Teltronic S.A.U. and/or PowerTrunk Inc. for any errors and omissions shall be limited to the correction of such errors and omissions. Teltronic S.A.U. and/or PowerTrunk Inc. welcomes any comment as a way to improve any delivered documentation.   The information contained herein has been prepared for the use of appropriately trained personnel, and it is intended for the purpose of the agreement under which the information is submitted. Any party using or relying upon this information assumes full responsibility for such use and in no event shall Teltronic S.A.U. and/or PowerTrunk Inc. be liable to anyone for especial, collateral, incidental, or consequential damages in connection with or arising out of the use of this information.   The information or statements given in these documents regarding the suitability, capacity or performance of the mentioned hardware or software products cannot be considered binding but shall be defined in the agreement made between Teltronic S.A.U. and/or PowerTrunk Inc. and the customer.   Teltronic S.A.U. and/or PowerTrunk Inc. reserves the right to revise these documents and to make changes to its content at any time, without prior notification.     Copyrights   No part of the information contained herein and the other referred documents may be copied, distributed or transmitted by any means to any other party without prior written permission of Teltronic S.A.U. and/or PowerTrunk Inc. The distribution of this document may be also covered by NDA (non-disclosure agreement) between Teltronic S.A.U. and/or PowerTrunk Inc. and the receiver.   Please also note that part of these contents even may be covered by patent rights.   This document, the referred documents and the described product are considered protected by copyright according to the applicable laws.   PowerTrunk and the PowerTrunk logo are registered trademarks of Teltronic S.A.U.   Copyright © PowerTrunk Inc. All rights reserved
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 3 of 38  01.01.00/1 Rev.1  CONTENTS:  1. INTRODUCTION ..........................................................................................................4 2. UNPACKING AND CHECKING ...................................................................................4 3. PREVIOUS CONSIDERATIONS..................................................................................4 4. INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY............5 4.1. STANDARDS.........................................................................................................5 4.2. FCC REGULATIONS COMPLIANCE....................................................................6 4.3. MECHANICAL AND ENVIRONMENTAL STANDARDS.......................................7 5. EQUIPMENT DESCRIPTION.......................................................................................9 5.1. VIEW ......................................................................................................................9 5.2. CONNECTORS....................................................................................................10 6. INSTALLATION GUIDE .............................................................................................12 6.1. NECESSARY EQUIPMENT.................................................................................13 6.2. BASIC PRE-CONFIGURATION ..........................................................................15 6.3. INSTALLATION...................................................................................................16 6.3.1. MAST/POLE INSTALLATION ........................................................................... 17 6.3.2. WALL INSTALLATION...................................................................................... 22 6.3.3. ANTI-VANDAL KIT INSTALLATION ................................................................. 25 6.3.4. CONNECTIONS................................................................................................ 27 6.3.4.1. SUPPORTED CONFIGURATIONS ............................................................ 28 6.3.4.2. CONNECTION OF THE EXTERNAL POWER SUPPLY ............................ 31 6.3.4.3. ANTENNA CONNECTION.......................................................................... 34 6.3.4.4. EXTERNAL ETHERNET CONNECTION ...................................................35 6.3.4.5. CONNECTION BETWEEN TWO MBS UNITS ........................................... 36 7. START UP/CONFIGURATION/VERIFICATION ........................................................37 8. INCIDENTS.................................................................................................................38 8.1. INTERFERENCE AT MBS UNIT .........................................................................38 8.2. OVER VOLTAGE PROTECTION ........................................................................38
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 4 of 38  01.01.00/1 Rev.1 1. INTRODUCTION The MBS Units are the outdoor modules that make up a Mast Mounted Base Station (MBS). They are independent units that can be interconnected with each other to increase the base station capacity. A MBS consists of a maximum of two MBS Units. This manual is common to all the equipment models, including all their options and accessories. The proper operation of any electronic device depends on its correct use. Therefore, it is recommended to follow the instructions showed in this manual.  2.  UNPACKING AND CHECKING The equipment is supplied with all the necessary materials for the installation, either on a mast/pole or on a wall:  MBS Unit includes the followings items  One power connector.   One Ethernet connector   RF super-flexible wire N-Male – N-Male.  Brackets for the installation. Besides, in some types of installation, as detailed below, it is necessary an additional material that is NOT supplied with the equipment. IMPORTANT: If any of the necessary elements to carry out the installation process described in this guide is missing or damaged, please contact your supplier.  3. PREVIOUS CONSIDERATIONS This manual contains information about instructions for installation, maintenance and use. Read the following pages before using this equipment. It is not advisable to switch on the equipment without having previously connected the antenna otherwise irreparable damage could be. It is important to use an antenna adjusted to the work frequency.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 5 of 38  01.01.00/1 Rev.1 4.  INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY    Most electronic equipment is susceptible to electromagnetic interference if it is not duly protected. If the MBS Unit is placed near unprotected electronic devices, they may malfunction.  The MBS Unit must not transmit without its antenna connected.  When installing the antenna, follow the guidelines for exposure of the human body to high and low frequency electromagnetic fields. Follow the supplier’s / manufacturer’s instructions.  Burns may be suffered if the antenna connector output is touched by bare skin when the MBS Unit is transmitting with the antenna disconnected.  Take care when handling the MBS Unit. It has edges, which may cut if handled incorrectly.  Maintenance and repair of these repeaters must be carried out by qualified personnel only.    4.1. STANDARDS  The equipment has been designed according to the following standards:  ETSI EN 300 394-1 – V3.1.1 (2007-11)  Terrestrial Trunked Radio (TETRA);Conformance testing specification; Part 1: Radio ETSI EN 301 489-1 – V1.8.1 (2008-04) Electromagnetic Compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements ETSI EN 301 489-18 - V1.3.1 (2002-08) Electromagnetic Compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 18: Specific conditions for TETRA equipment EN 60950-1:2006, EN 60950-1:2006/A1:2010 Information technology equipment - Safety -- Part 1: General requirements EN 60215-1989, EN 60215:1989/A1:1992, EN 60215:1989/A2:1994  Safety requirements for radio transmitting equipment
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 6 of 38  01.01.00/1 Rev.1 EN 60950-22:2006, EN 60950-22:2006/A11:2008 Information technology equipment - Safety -- Part 22: Equipment installed outdoors EN 50383:2010 Basic standard for the calculation and measurement of electromagnetic field strength and SAR related to human exposure from radio base stations and fixed terminal stations for wireless telecommunication systems (110 MHz - 40 GHz) EN 50385:2002 Product standard to demonstrate the compliance of radio base stations and fixed terminal stations for wireless telecommunication systems with the basic restrictions or the reference levels related to human exposure to radio frequency electromagnetic fields (110 MHz - 40 GHz) - General public These standards ensure the essential requirements set out in Article 3 of Directive 1999/5/EC.  4.2. FCC REGULATIONS COMPLIANCE The equipment has been designed to fulfil the applicable compliance regulations. The equipment complies with Part 15 of the FCC Title 47 of the Code of Federal Regulations.  Operation is subject to the condition that this device does not cause harmful interference. The equipment complies with the applicable Part 90 of the FCC Title 47 of the Code of Federal Regulations.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 7 of 38  01.01.00/1 Rev.1 4.3. MECHANICAL AND ENVIRONMENTAL STANDARDS The equipment complies with the following standards: EN 60068-2-1:2007    * No Functional.  -40 ºC. Duration: 72 h    * Functional: -30 ºC. Duration: 16 h. Environmental testing -- Part 2-1: Tests - Test A: ColdEN 60068-2-2:2007    * No Functional.  +85 ºC. Duration: 72 h    * Functional: +60 ºC. Duration: 16 h. Environmental testing -- Part 2-2: Tests - Test B: Dry heat EN 60068-2-78:2001    * Functional +60 ºC 93%. Duration 21 days. Environmental testing -- Part 2-78: Tests - Test Cab: Damp heat, steady state EN 60068-2-30:2005    * Functional: 6 cycles  24 hours:        • 12 hours. Temperature: +60 ºC. Relative humidity: 95% ± 5%        • 12 hour: Temperature +25 ºC. Relative humidity: 98% ± 5% Environmental testing -- Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) EN 60068-2-11:1999 No functional : 336 hours. +35 ºC +/- 2 ºC. 5% ClNa Environmental testing -- Part 2: Tests - Test Ka: Salt mist EN 60529:1991 EN 60529:1991/A1:2000     * No functional.  IP66 Degrees of protection provided by enclosures (IP Code) EN 60068-2-9: 1999    * No functional.         • Proc. B: 20 hours of solar radiation and 4 hours of darkness       • Temperature: +40 ºC       • Humidity: 65%       • Duration:  10 days Environmental testing -- Part 2: Tests - Guidance for solar radiation testing EN 60068-2-64:2008    * No functional:        • Duration: 30 minutes by axe       • 5-20 Hz. ASD: 1 m2/s3.       • 20-200 Hz.  ASD;  - 3dB/oct Environmental testing -- Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance  EN 60068-2-6:2008    * No functional:       • Duration: 5 sweep by axe      • 5-9 Hz. Displacement 1.2 mm.      • 9-200 Hz.  Acceleration 4m/s2 Environmental testing -- Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 8 of 38  01.01.00/1 Rev.1 UNE-EN 60598:2009    * Vibration type: Sine swept     * Frequency range: From 10 to 55 Hz     * Amplitude (peak):                • 10 Hz   Amplitude (peak): 1.4 mm        • 38 Hz Amplitude (peak): 20 m/s2         • 55  Hz Amplitude (peak): 20 m/s2    * Number of axes:  3 axes      * Swept ratio:  1 Oct./min.     * Duration: 30 min./axis  Vibration: simulation of the fixing between MBS unit and mast.  Eurocode  UNE-EN  1991-1-4  (September  2007)   * Wind speed: 200 km/h (55.55 m/s) (Safety factor 1.5)   * Height in post:  20 m  Protection for avoiding damages either in the enclosure and the fixing parts, due to meteo effects such as strong gusts of wind
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 9 of 38  01.01.00/1 Rev.1  5. EQUIPMENT DESCRIPTION 5.1. VIEW 5 4 2 1 3 1 2 Male panel connector  Female cable connector  3
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 10 of 38 01.01.00/1 Rev.1  5.2. CONNECTORS • 1.- Terminal with the following meaning depending on the MBS Unit Power option: - AC MBS Units:  Neutral contact (N). - DC MBS Units:  Negative contact (-). • 2.- Terminal with the following meaning depending on the MBS Unit Power option: - AC MBS Units:  Line contact (L). - DC MBS Units:  Positive contact (+). • 3.- Power supply Earth contact. • 4.- Pressure equalizer. • 5.- Chassis Earth contact. • ETH: Connector that allows Ethernet connection between MBS Units. It also can be used as Maintenance Ethernet connector. • PoE/ETH: Power Over Ethernet (IEEE 802.3at) connector. It provides power supply (48 VDC) and Ethernet connection to a PoE radio link. It can be used as Maintenance Ethernet connector if there is not radio link (Poe) connected. • PoE: Power Over Ethernet (IEEE 802.3at) connector. It provides power supply (48 VDC) and Ethernet connection to a PoE radio link. • SYNC OUT: Synchronism output connector. It provides synchronism to a second MBS Unit through its SYNC_IN connector. • SYNC IN: Synchronism input connector. • DIV OUT: Output reception connector. It provides the receiver chain 2 to the next MBS Unit through its DIV IN connector. • DIV IN: Reception antenna connector (receiver chain 2). It is connected to an antenna or to a MBS Unit DIV OUT connector (diversity 2). • ANT: Transmission/reception antenna power connector (receiver chain 1). • POWER OUT: Output power supply connector. It provides power supply to another MBS Unit with the same Power Supply option. • POWER IN: Input power supply connector (VAC or VDC).
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 11 of 38 01.01.00/1 Rev.1  Note:  POWER_IN and POWER_OUT connectors have a coding key to avoid wrong connections; on the following table is showed the location of this coding key depending on the MBS Unit power supply option.  External view of power supply panel connector AC Power Supply  DC Power Supply    Note: The amount of power delivered by both PoE and PoE/ETH connectors to the radio links can not exceed 35 W in total.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 12 of 38 01.01.00/1 Rev.1  6. INSTALLATION GUIDE  The following recommendations must be followed before powering on the MBS Unit module. Next diagram shows the steps to be followed to carry out the installation:            Verification of the necessary equipment   Basic Pre-Configuration   Final location installation   Final Configuration/Verification
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 13 of 38 01.01.00/1 Rev.1   6.1. NECESSARY EQUIPMENT   Make sure you have the necessary equipment depending on the configuration to install. If any of the elements necessary to carry out the installation process described in this manual, were lost or damaged, contact your supplier and / or installer.  Necessary equipment Element  Code  Comments MBS Unit  D148x01  “x” varies depending on band.  Each MBS Unit includes: - MBS Unit equipment -  Power supply cable connector -  Ethernet cable connector  -  RF superflexible wire N-Male ↔ N-Male -  Brackets for installation Anti-vandal kit  D014000  It is only necessary if anti-vandal protection is required Ethernet cable connector  225120  Every MBS Unit includes one connector of this type; if a MBS Unit must be connected to two radio links, it is necessary to have a second unit. RF superflexible wire N-Male ↔ N-Male 208931  Each MBS Unit includes one cable of this type; if a MBS Unit requires diversity 2 on reception it is necessary to have a second  unit. Additional carrier interconnection kit D014001  It is mandatory in case of connecting a second MBS Unit to the first MBS Unit.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 14 of 38 01.01.00/1 Rev.1  Additional equipment to be considered for installation Element  Comments Cable to power the MBS Unit.  See features in external power connection section. One power supply cable connector is supplied with the MBS Unit. Ethernet cable to connect PoE radio links See features in Ethernet connection section. One Ethernet cable connector is supplied with the MBS Unit. Antenna coaxial cable and antenna.  See features in Antenna connection section.  Tools Element  Comments Toolbox  In addition to the usual material used for installations (wrenches, screwdrivers ...) it is necessary to use: - Torque wrench for 17 mm hexagonal  nut capable of delivering 15 Nm. - Vulcanizable tape. Ethernet Cable  Cable to make specific maintenance tasks in the field
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 15 of 38 01.01.00/1 Rev.1  6.2. BASIC PRE-CONFIGURATION Before connecting the MBS Unit to the infrastructure it should have the IP address correctly configured in order to have remote access once it is connected (to set the IP address, see the configuration chapter (F067220) in technical manual). Steps: •  Apply power supply to the MBS through its POWER_IN  connector. •  Wait 3 minutes until the MBS Unit initializes. •  Connect the PC, to set the IP address, to the  ETH connector. •  Change the IP address according to the network IP addressing. •  Check that IP address was successfully changed through a “ping” from the PC to the new IP address of the MBS Unit.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 16 of 38 01.01.00/1 Rev.1  6.3. INSTALLATION The MBS has been designed to be mounted on both mast/pole and wall. This chapter provides the necessary steps to be followed for a right MBS Unit installation. At least two people are required to carry out the installation of a MBS Unit on a mast/pole. Bracket system: 1 x Bracket  2 x clamp (2 holes)  2 x clamp (4 holes)   4 x Bolt M10x180  (Clamp attachment) 6 x Bolt M10x40 (lateral attachment MBS-Bracket & Clamp-Bracket) 2 x Bolt  M10x20 (Top attachment MBS-Bracket)     12 x Grower washer DIN 127 Ø10 12 Plain washer DIN125 x Ø10    ---
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 17 of 38 01.01.00/1 Rev.1  6.3.1.  MAST/POLE INSTALLATION The different section types of mast/pole where the MBS Unit can be mounted are the following ones:  Circular section: Diameter from 30 mm to 130 mm.  Square section: From 30 mm x30 mm to 85 mm x85 mm.  L section: From 30 mm x30 mm to 110 mm x110 mm.   In the choice of the mast/pole where the MBS Unit is being installed the following recommendations must be followed:   The mast/pole has to support the loads due to the installation of some elements on them.  The mast/pole has to support the loads due to the action of the wind, snow as well as its own weight, because these are going to induce its flexion.  The mast/pole must have the enough inertia both lateral and frontal in order that the action of different loads does not induce permanent deformations on it.  The manufacturer of the mast/pole must evaluate the structural factor of the mast/pole correctly depending on its type.  It is necessary to take into account both the height where the MBS Unit is installed and its weight/dimensions (See section “MBS Unit” in chapter (F067326) “SBS Technical Description” in the Technical Manual).   It is recommended to choose a lattice mast/pole in case of this one has a high height and it is going to be submitted to important flexion efforts. In any case, it is responsibility of the manufacturer of the mast/pole to determine if the resistant section of mast/pole is suitable.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 18 of 38 01.01.00/1 Rev.1 The brackets should be installed tight enough to support the MBS Unit without causing deformation of the mast/pole or areas of corrosion. Once mounted in its definitive location, if the vandal resistant kit is available, it will prevent the access / disassembly not authorized. In case of installing more than one MBS Unit on the same mast/pole, it is recommended not to mount one above the other one to avoid the heat transfer from the MBS Unit low to the MBS Unit high. If the MBS Units have to be installed in the same vertical axis these must be oriented in different directions to increase the separation of them as far as possible, depending on the length of wiring between both equipments (1.5 m approximately).
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 19 of 38 01.01.00/1 Rev.1   Steps to install a MBS on a mast/pole:  1)  Place the MBS Unit bracket on the mast/pole as follows. Note: Handle the MBS Unit bracket with care if it rests on the floor.  Place some protection underneath to prevent scratches on the surface. a)  Secure 4 holes clamps on the bracket by tightening the bolts with a 15 Nm torque, using a 17 mm torque wrench, do not forget to place the washers   b)  Install the bracket to the desired final location on the mast/pole. Embrace the 2 holes clamps and screw these to the bracket with a 17 mm wrench and 15 Nm torque. Due to the length of the bolts it is advisable to screw them slowly.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 20 of 38 01.01.00/1 Rev.1    2)  Place MBS Unit on the bracket as follows. a)  Raise the MBS Unit to the position where the bracket is placed on the mast/pole and hang it on the bracket, tilting slightly to match the bracket guides as indicated in the following figure:
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 21 of 38 01.01.00/1 Rev.1  b)  Put the bolts of the MBS Unit and washers to the bracket with a 17 mm wrench and 15 Nm torque.  Note: If anti-vandal kit is available (D014000), lateral bolts should be placed after mounting the anti-vandal kit.   3)  Make the necessary cable connections as described in the connections section in this guide.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 22 of 38 01.01.00/1 Rev.1  6.3.2.  WALL INSTALLATION To install the MBS Unit on a wall, make the following steps: 1)  Mark the position of the holes using the bracket as a template itself with the help of a level. Note: To ensure proper ventilation there must be at least 700 mm clearance above and below each MBS Unit. There must also be a minimum distance of 300 mm free on both sides of the MBS Unit. Note: The screws, expansion bolts and washers needed to secure the brackets to wall are not supplied with the unit. The distance between the holes are shown in the following figure.      2)  Drill holes on the wall and insert a rawlplug in each hole.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 23 of 38 01.01.00/1 Rev.1  3)  Place the bracket over the rawlplug and insert the bolts and washers. Finally screw them with a 17 mm wrench and 15 Nm torque.                         4)  Place the MBS Unit on the bracket as follows. a)  Raise the MBS Unit to the position where the bracket is placed and hang it on the bracket, tilting slightly to match the anchor guides as indicated in the following figure:
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 24 of 38 01.01.00/1 Rev.1  b)  Put the bolts of the MBS Unit and washers to the bracket with a 17 mm wrench and 15 Nm torque. The order is bolt + grower washer + plain washer. Note: If anti-vandal kit is available (D014000), lateral bolts should be placed after mounting the anti-vandal kit.       5)  Make the necessary cable connections as described in the connections section in this guide.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 25 of 38 01.01.00/1 Rev.1  6.3.3.  ANTI-VANDAL KIT INSTALLATION The anti-vandal kit for MBS Unit is an optional accessory (D014000). Either the MBS Unit is mounted on a mast/pole or on a wall, the anti-vandal kit, is performed as follows. Take into account that the installation of the ant-vandal kit should be done once you have completed the wiring connections of the MBS Unit. Anti-vandal Kit:  Anti-Vandal Kit   6 x Torx screw M3X4  6  x Grower washer 1 x padlock             -  Place the anti-vandal kit and slide the kit guides as shown on the following figure:
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 26 of 38 01.01.00/1 Rev.1 -  Place the padlock and screw the attachment bolt to the bracket with a 17 mm wrench and 15 Nm torque.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 27 of 38 01.01.00/1 Rev.1  6.3.4.  CONNECTIONS This section shows the connections to be made and the characteristics of the material to be used. The MBS Unit is a weather-protected device once the equipment has been installed in its final location; make sure that there is no MBS Unit connector without plug or cable connected. Besides, the external wiring connections of the MBS Unit must be protected from weather, (vulcanizable tape can be used if it is necessary).
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 28 of 38 01.01.00/1 Rev.1  6.3.4.1.  SUPPORTED CONFIGURATIONS  a)  ONE MBS UNIT WITHOUT DIVERSITY IN RECEPTION The connections are the following ones:  Power supply 220/110 VAC or 24 VDC.  From ANT connector to the antenna.  Connection with radio link through PoE connector.  Maintenance through PoE/ETH N or ETH connector.            Of                        ANT DIV_IN DIV_OUT POWER_IN PoE/ETH SYNC_OUT POWER_OUT PoE ETH SYNC_IN        Radio link Antenna 1 (Tx/Rx) Power Input
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 29 of 38 01.01.00/1 Rev.1  b)  ONE MBS UNIT WITH DIVERSITY 2 IN RECEPTION The connections are the following ones:  Power supply: 220/110 VAC ó 24 VDC.  From ANT connector to the first antenna.  From DIV IN connector to the second antenna.  Connection with the radio link through PoE connector.  Maintenance through PoE/ETH or ETH connector.                  ANT DIV_IN DIV_OUT POWER_IN PoE/ETH SYNC_OUT POWER_OUT PoE ETH SYNC_IN Power  Radio link  Antenna 2 (Rx2) Antenna 1 (Tx/Rx1)
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 30 of 38 01.01.00/1 Rev.1  c)  TWO MBS UNIT WITH DIVERSITY 2 IN RECEPTION The connections are the following ones:  Power supply for the MBS Unit 1: 220/110 VAC or 24 VDC.  From ANT connector of the MBS Unit 1 to the first antenna.  From ANT connector of the MBS Unit 2 to the second antenna.  Connection with the radio links through PoE connector of both MBS Units.  Maintenance through PoE/ETH connector of both MBS Units                      Power          Radio link 2         Radio link 1 ANT DIV IN DIV OUT POWER IN PoE/ETH SYNC OUT POWER OUT PoE ETH SYNC IN Antenna 2 (TXF2/Rx2) Antenna 1 (TxF1/Rx1) TX F1: Output Transmission Frequency 1 TX F2: Output Transmission Frequency 2 RX1: Reception “Chain 1” of frequencies 1 y 2 RX2: “Recepetion Chain 2” of frequencies 1 y 2 ANT DIV IN DIV OUT POWER IN PoE/ETH SYNC OUT POWER OUT PoE ETH SYNC IN
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 31 of 38 01.01.00/1 Rev.1   6.3.4.2.  CONNECTION OF THE EXTERNAL POWER SUPPLY   Check that the power supply source and/or the battery to be used are adapted to the type of MBS Unit (AC/DC) and meets the voltage and current requirements necessary to supply the equipment.   a)  MBS Unit with AC power supply source:  Nominal voltage: 110/220 VAC (Range: from 94 to 264 VAC).  Use the power cable connector provided with the MBS Unit to connect the MBS Unit to the power supply source. Use a cable of 3 wires; with weather protection; with the following features:    Cable diameter: 6 mm - 12 mm.   Cable section: 4 mm² (0.6/1KV) or AWG-11.  Ensure that the connection is made in the correct way (Line, Neutral and Earth) following the next steps:   Strip cable and wires (stripping length 8 mm -9 mm). NOTE: The earth cable must be 2 mm longer.   Push the cable through the cable gland and the hood/housing and insert the wires into the insert respecting the correct polarity.  8-9mm Neutral (N) Line (L) Earth (PE)
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 32 of 38 01.01.00/1 Rev.1    Fix each wire tightening each pin from the front side with a hexagonal screwdriver (Allen number 2).   Push the insert back into the hood/housing.   Fix the assembly tightening the top locking screw and tightening the cable gland nut on the back of the hood/housing.  b)  MBS Unit with DC power supply source:  Nominal voltage: 24 VDC (Range: from 21.6 to 31.2 VDC).  Use the power cable connector provided with the MBS Unit to connect the MBS Unit to the power supply source. Use a cable of 3 wires with weather protection and the following features:    Cable diameter: 10 mm - 14 mm.   Cable section: 6 mm² (0.6/1KV) or AWG-10.   Maximum cable length1: -  One MBS Unit: 85 m. -  Two MBS Units: 42 m.                                                  1 The greater the cable length, the greater the voltage drop in it. The specified length has been calculated to ensure minimum operating voltage of the MBS Unit, assuming a minimum voltage of 24V at the output of the power system and a typical resistivity of copper wire Ω ≤ 0.0172 mm2/m.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 33 of 38 01.01.00/1 Rev.1  Ensure that the connection is made in the correct way (Positive, Negative and Earth) following the next steps:   Strip cable and wires (stripping length 8 mm - 9 mm). NOTE: The Earth cable must be 2 mm longer.    Push the cable through the cable gland and the hood/housing and insert the wires into the insert respecting the correct polarity.     Fix each wire tightening each pin from the front side with a hexagonal screwdriver (Allen number 2).    Push the insert back into the hood/housing.  8-9mm Negative (-) Positive (+) Earth (PE)
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 34 of 38 01.01.00/1 Rev.1    Fix the assembly tightening the top locking screw and tightening the cable gland nut on the back of the hood/housing.  c)  In both cases:  The power supply cable to the MBS Unit must be provided by the installer with the proper power supply connector adapted for the connection to the electrical network or to a 24 VDC source   Ensure that the earth connection is made. The MBS Unit has an earth connector; this connector will connect to the earth protection of the installation, which is different to the earth protection of the lightning rod. Make this connection with a cable of, at least, 25 mm2 section (or AWG-3). NEVER use a gas or electricity conduit as an earth.   6.3.4.3.  ANTENNA CONNECTION  With every MBS Unit, a RF super-flexible wire, N-Male – N-Male, is supplied to connect the ANT connector of the MBS Unit with the RF wire of the antenna. Note: In case of installation a MBS Unit with diversity 2, it is recommended to contact your supplier and/or installer who will provide the additional RF super-flexible wire (Cod. 208931).  The RF assembly depends on the cable type used in the installation up to the antenna.   The RF cable must have a protection against water entry (vulcanizable tape).  Choose the most adaptable antenna for the installation. The antenna must have an impedance of 50 ohms to the equipment transmission frequency. Install the antenna in accordance with the manufacturer’s instructions.  Use a coaxial cable, avoiding as much as possible large cable lengths. Cable impedance is 50 ohms.
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 35 of 38 01.01.00/1 Rev.1  In installations with diversity, the greatest gain is achieved by placing the antennas on the same horizontal plane with a minimum distance of 5.5 m between them.  Measure the ROE of the installation. Never accept a ROE greater than 2.  6.3.4.4.  EXTERNAL ETHERNET CONNECTION  The Ethernet cable connector, to connect the MBS Unit with the radio link (PoE), is supplied with every MBS Unit. Note:  In the case of connection to two radio links, it is recommended to contact your supplier and/or installer who will provide the additional Ethernet cable connector.  The Ethernet wire for the radio link connections is supplied  by the installer, and must have the following characteristics:   Cable with 8 wires, FTP cat5E with outdoor protection.   Diameter: 6.5 mm to 9.5 mm.   Maximum length: 100 m   Mount the wire on the connector according to the TIA / EIA 568B standard (The assembly requires no tools, is done manually).  Pin  Color T568B  Pins on plug face (socket is reversed) 1   White/Orange 2   Orange 3   White/Green 4   Blue 5   White/Blue 6   Green 7   White/Brown) 8   Brown
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 36 of 38 01.01.00/1 Rev.1  6.3.4.5.  CONNECTION BETWEEN TWO MBS UNITS To connect two MBS Units you must have the interconnection kit for additional carrier (Cod. D014001). This is obtained as an independent accessory. Apart from the power wiring, antennas and radio links to connect as indicated in the section of supported configurations, it should be considered the use of interconnection kit between the two Units MBS, as indicated bellow.  Connections  MBS_1 connector MBS_2 connector Power Supply  Power_OUT  Power_IN Ethernet ETH ETH Synchronism SYNC_OUT SYNC_IN DIV_OUT DIV_IN Diversity in reception DIV_IN DIV_OUT  ANTDIV IN DIV OUT POWER IN PoE/ETH SYNC OUT POWER OUT PoE ETH SYNC IN  ANT DIV IN DIV OUT POWER IN PoE/ETH SYNC OUT POWER OUT PoE ETH SYNC IN
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 37 of 38 01.01.00/1 Rev.1  7. START UP/CONFIGURATION/VERIFICATION  IMPORTANT: Ensure that the power supply of the MBS Unit is the proper one before switch it on; an erroneous power supply can cause damages in the equipment. Every MBS Unit has in its labelling the diverse options that it offers. If the MBS Unit includes the option O148017, this it will have to be powered with AC (220/110 VAC), however, if the MBS Unit includes the option O148018 it will have to be powerred with +24 VDC nominal voltage.  Preliminary considerations for carrying out the MBS Unit start up: •  To start up the equipment, this must have the final IP correctly configured (see chapter of infrastructure configuration (F067220) in the Technical Manual). •  Refer to the radio link used to configure this device. Make sure this element is properly connected to ground.  The steps to perform the final settings are:  1.  Before connecting power supply to the MBS Unit, make sure the right voltage level reaches the power supply cable connector. 2.  Provide power to the MBS Units through the POWER_IN connector. 3.  Wait for the MBS Unit initialization (about 3 minutes). 4. Verify that you have access to the MBS (by performing a "ping"). Make partial checks in case of no response from the MBS, perform pings to intermediate elements: SNI Æ Node radio link Æ remote site radio link Æ MBS. 5.  From NMS, register the MBS Unit(s), completing the necessary settings (see chapter of infrastructure configuration, F067220, and the client's user manual NMS, F067201). 6. Verify the absence of alarms in monitoring module and check with a radio terminal that it is registered and you can make and receive calls. In case of interference or coverage fault alarms see chapter of the infrastructure adjustment (F067218).
Code: D148X01_DDS06  MBS USER AND INSTALLATION MANUAL  Date: 05/10/11 Page: 38 of 38 01.01.00/1 Rev.1  8. INCIDENTS  The MBS Unit must be repaired by authorized technical personnel only. There will not be performed any repair of the MBS Unit and it will have to be sent to factory except for the change of the pressure equalizer or the overvoltage protections.  8.1. INTERFERENCE AT MBS UNIT This alarm is monitored in the NEBULA (NMS) management and configuration module. See the infrastructure event list (F067516) in NEBULA Technical Manual. Any interference in the MBS Unit is activated when there are a large number of consecutive invalid events in the MBS Unit. A reception fault is considered when a level higher than the threshold for reception of the carrier, but is not recognized as a valid signal. Depending on the signal level, interference is considered low or high. So, if the level of signal is above the threshold for reception and below the threshold set to high interference and is not recognized as a valid sign, it will be a low interference alarm. If the signal level is above the threshold set to high interference and is not recognized as a valid signal, the low level alarm would disappear (if it happened) and high interference would produce. These alarms are turned off with any valid signal reception for low interference case, and with more than one consecutive right reception for high-level interference.  8.2. OVER VOLTAGE PROTECTION The MBS Unit has several protections against lightning and surges, in any case the action of these protections generate an alarm in the NMS client which disappear when the protective element is replaced by authorized technical staff. a)  Protection against lightning and power surges This protection is located within the MBS Unit. It should be changed every time it breaks even if the MBS Unit continues functioning properly. An alarm in the NMS Client is reported showing that the replacement of this type of protection is needed. b)  Protection against lightning and surges in the RF connections This protection is located inside the connectors themselves (ANT and DIV_IN). These connectors have a gas discharger that when it is broken, it ceases to receive/transmit signal through the connector. The NMS Client provides a reflected alarm when the ANT discharger fails and diversity alarm when the DIV_IN discharger fails.

Navigation menu