Texas Instruments 110190EM915 The CC1101-CC1190EM-915 is a development tool for TIs sub-1 GHz CC1101 and CC1190 devices. User Manual EVALUATION BOARD KIT MODULE EVM ADDITIONAL TERMS

Texas Instruments Inc. The CC1101-CC1190EM-915 is a development tool for TIs sub-1 GHz CC1101 and CC1190 devices. EVALUATION BOARD KIT MODULE EVM ADDITIONAL TERMS

Users Manual

Download: Texas Instruments 110190EM915 The CC1101-CC1190EM-915 is a development tool for TIs sub-1 GHz CC1101 and CC1190 devices. User Manual EVALUATION BOARD KIT MODULE  EVM  ADDITIONAL TERMS
Mirror Download [FCC.gov]Texas Instruments 110190EM915 The CC1101-CC1190EM-915 is a development tool for TIs sub-1 GHz CC1101 and CC1190 devices. User Manual EVALUATION BOARD KIT MODULE  EVM  ADDITIONAL TERMS
Document ID2131693
Application ID0qADN5b9DE6IwJrMzN166g==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize35.61kB (445081 bits)
Date Submitted2013-12-02 00:00:00
Date Available2013-12-02 00:00:00
Creation Date2013-11-07 12:43:45
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2013-11-07 12:43:45
Document TitleEVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS
Document CreatorMicrosoft® Word 2010
Document Author: Texas Instruments, Incorporated

SWRU284A
November 2013
CC1101-CC1190EMK Quick Start Guide
Opening the box and using the modules with SmartRF04EB
1. Kit Contents
2 x CC1101-CC1190EM (869 or 915 MHz)
2 x Pulse W5017 Antennas (2 dBi)
The 869 MHz RF board is tested to comply with
ETSI/R&TTE over temperatures from 0 to +70°C. The
915 MHz RF board is FCC and IC certified.
The boards should not be modified to operate in other
frequency bands than what they have been designed for.
FCC/IC Regulatory Compliance (915 MHz board only)
FCC Part 15 Class A Compliant
IC ICES-003 Class A Compliant
4a. Apply Power
2. How to Use the Modules
3. Plug EM into SmartRF04EB
The CC1101-CC1190 Evaluation Module
(EM) boards can be plugged into the
SmartRF04EB (EB), which is included in
the CC1101DK. This board lets you control
the devices from SmartRF™ Studio and it
can also be used as a development
platform.
The evaluation module is also supported
by the SmartRF TrxEB, included in the Insert the EM into the EB. Attach the
CC11xL,
CC1120
and
CC1200 antenna firmly.
development kits.
This Quick Start Guide describes how to
properly power the SmartRF04EB with a
CC1101-CC1190EM and how to control
the combo from SmartRF Studio.
4b. Power the EB
Caution! The kit contains ESD sensitive
components. Handle with care to prevent
permanent damage. To minimize risk of
injury, avoid touching components during
operation if symbolized as hot.
4c. Power the EM
The EB can be powered from different
sources: USB, Battery or an External
Power Supply
The voltage regulator on the EB supplies
3.3 V to the assembly, but it can only
source up to 150 mA. It cannot supply the Connect the EB to a USB port on a PC.
CC1101-CC1190EM since it can consume
more than 300 mA. An external power
supply is therefore required for powering
the EM.
It is possible to have separate power
sources for the EB and for the EM. This is
controlled with the strap between I_OUT
and I_IN on P5 (the screw terminal).
Remove it to allow separate power
supplies.
4d. Optional: Same Power
Supply for both EB and EM
As noted in 4a, remove the strap on P5
and connect the external power supply as
shown in the picture above. The red wire is
the positive supply and the black wire is
GND.
Alternatively, connect a 9 V, nonrechargeable, alkaline battery (not included This will power the EM directly from the
in the kit) to the battery connector on the external power supply, whereas the rest of
bottom side of the board.
the EB will be powered from USB or the
battery.
Note that if multiple power sources are
connected, the source with the highest The power supply range should be within
voltage will power the EB. This means that 3.0 to 3.6 V.
you should disconnect any attached
battery when using USB power; otherwise
the battery will be drained.
5. Set Power Switch
6. External Power Supply Range
With the test setup in 4a-4c, the EB is
connected to a 3.3 V supply through the
on-board voltage regulator and the EM is
powered by the external supply. Since the
EB is powered through a regulated 3.3 V
supply the signals going from CC1101If EB and EM are powered from different CC1190 to the EB (and vice versa) need to
sources as described in 4a-4c, the switch be within 3.0 V to 3.6 V. The external
supply connected to the EM when using
should be set to the rightmost position.
the setup in 4a-4c is therefore limited to 3.0
GND
VDD
If EB and EM are powered from the same V to 3.6 V.
Connect a 3.3 V voltage source between external supply as described in 4d, the With the setup in 4d the supply range is
the 3.3 V and 0 V terminals. 3.3 V is the switch should be set to the leftmost limited 2.7 V to 3.6 V.
position.
middle terminal.
In this case, the on-board voltage regulator This switch can be used to turn off the EB
will be bypassed. Note that the strap on P5 by switching it to the opposite position of
that used to turn it on.
should not be removed.
External Power Supply1 Requirements:
Nom Voltage: 3.3VDC
Max Current: 800 mA
Efficiency Level V
When using an external power supply, make sure it meets the listed requirements in addition to complying with applicable regional product regulatory and safety certification
requirements such as UL, CSA, VDE, CCC, and PSE
SWRU284A
November 2013
SmartRF™ Studio
1. Download and Install SmartRF Studio
2. Launch SmartRF Studio
Before connecting the EB to your PC, download SmartRF™
Studio from www.ti.com/smartrfstudio.
Install the program and follow the instructions in the wizard.
Connect the EB with a CC1101-CC1190EM to the PC using
the USB cable and install the USB driver as described in the
manual.
Launch SmartRF Studio and double click on the highlighted
CC1101 device icon to get complete control of the device from
the PC.
You can now configure the radio, run tests, export register
settings and run link tests with another CC1101-CC1190EM on
a SmartRF04EB connected to the PC.
3. Configure the Radio
In order to control the CC1190 select CC1190 as “Range Extender” and select the appropriate “EM Revisions” as shown (either
869 or 915 MHz). You can now use all the features in Studio as for a standalone EM. Test the performance of the radio using
some of these features:



Continuous TX: Output power, spectrum
Continuous RX: Received signal strength, synchronous/asynchronous serial RX mode
Packet TX/RX: Link and sensitivity testing
References
Please visit





http://www.ti.com/product/cc1190
http://www.ti.com/tool/cc1101cc1190emk868
http://www.ti.com/tool/cc1101cc1190emk915
http://www.ti.com/lit/swra356 (Using the CC1190 Front End with CC1101 under EN 300 220)
http://www.ti.com/lit/swra361 (Using the CC1190 Front End with CC1101 under FCC 15.247)
Download the SmartRF™ Studio software, as well as datasheets, reference designs and application notes.
You will also find a lot of information on the TI E2E forum at http://e2e.ti.com
We hope you will enjoy working with the CC1101 and CC1190 devices.
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS
Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions:
The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims
arising from the handling or use of the goods.
Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from
the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO
BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH
ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES.
Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This
notice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safety
programs, please visit www.ti.com/esh or contact TI.
No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and
therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design,
software performance, or infringement of patents or services described herein.
REGULATORY COMPLIANCE INFORMATION
As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal
Communications Commission (FCC) and Industry Canada (IC) rules.
For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT,
DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer
use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing
devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency
interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will
be required to take whatever measures may be required to correct this interference.
General Statement for EVMs including a radio
User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and
power limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local
laws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate this
radio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited and
unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory
authorities, which is responsibility of user including its acceptable authorization.
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant
Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the
equipment.
FCC Interference Statement for Class A EVM devices
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Interference Statement for Class B EVM devices
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
For EVMs annotated as IC – INDUSTRY CANADA Compliant
This Class A or B digital apparatus complies with Canadian ICES-003.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
Concerning EVMs including radio transmitters
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Concerning EVMs including detachable antennas
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum
permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain
greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada.
Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de
l'utilisateur pour actionner l'équipement.
Concernant les EVMs avec appareils radio
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Concernant les EVMs avec antennes détachables
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain
maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à
l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel
d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans
cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
【Important Notice for Users of EVMs for RF Products in Japan】
】
This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan
If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:
1.
2.
3.
Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and
Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of
Japan,
Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this
product, or
Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with
respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note
that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.
Texas Instruments Japan Limited
(address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan
http://www.tij.co.jp
【無線電波を送信する製品の開発キットをお使いになる際の注意事項】
本開発キットは技術基準適合証明を受けておりません。
本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。
1.
2.
3.
電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。
実験局の免許を取得後ご使用いただく。
技術基準適合証明を取得後ご使用いただく。
なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。
上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。
日本テキサス・インスツルメンツ株式会社
東京都新宿区西新宿6丁目24番1号
西新宿三井ビル
http://www.tij.co.jp
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
EVALUATION BOARD/KIT/MODULE (EVM)
WARNINGS, RESTRICTIONS AND DISCLAIMERS
For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished
electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in
laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks
associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end
product.
Your Sole Responsibility and Risk. You acknowledge, represent and agree that:
1.
2.
3.
4.
You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug
Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees,
affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes.
You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable
regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates,
contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical)
between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to
minimize the risk of electrical shock hazard.
Since the EVM is not a completed product, it may not meet all applicable regulatory and safety compliance standards (such as UL,
CSA, VDE, CE, RoHS and WEEE) which may normally be associated with similar items. You assume full responsibility to determine
and/or assure compliance with any such standards and related certifications as may be applicable. You will employ reasonable
safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail to
perform as described or expected.
You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.
Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the
user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and
environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact
a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the
specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or
interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the
load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures
greater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components include
but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the
EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please
be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable
in electronic measurement and diagnostics normally found in development environments should use these EVMs.
Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives
harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in
connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims
arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected.
Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such
as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices
which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate
Assurance and Indemnity Agreement.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 6
XMP Toolkit                     : 3.1-701
Part                            : 1
Conformance                     : B
Producer                        : Microsoft® Word 2010
Keywords                        : SSZZ027E
Creator Tool                    : Microsoft® Word 2010
Create Date                     : 2013:11:07 12:43:45+01:00
Modify Date                     : 2013:11:07 12:43:45+01:00
Title                           :  EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS
Creator                         : Texas Instruments, Incorporated
Description                     : Important Notice
Author                          : Texas Instruments, Incorporated
Subject                         : Important Notice
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZAT110190EM915

Navigation menu