Texas Instruments 2538EM The CC2538EM is a development tool for the 2.4 GHz CC2538 IEEE802.15.4 System-on-Chip from TI. User Manual CC2538 Development Kit Quick Start Guide

Texas Instruments Inc. The CC2538EM is a development tool for the 2.4 GHz CC2538 IEEE802.15.4 System-on-Chip from TI. CC2538 Development Kit Quick Start Guide

Users Manual

 March 2013   Web sites:  www.ti.com/lprf E2E Forum:  www.ti.com/lprf-forum Make sure to subscribe to the Low-Power RF Newsletter to receive information about updates to documentation, new product releases, and more. Sign up on the TI web pages.   CC2538 Development Kit Quick Start Guide  Opening the Box and Running the Packet Error Rate Test  1. Kit Contents    2 x SmartRF06 Evaluation Boards (SRF06EB) 2 x CC2538 Evaluation Modules (CC2538EM) 1 x CC2531 USB dongle (sniffer) 2 x Micro USB Cables Documentation  The RF boards in this kit are FCC and IC certified and tested/comply with ETSI/R&TTE over temperature from 0 to 35°C. 2. SmartRF06EB Overview       3. Plug the EM into the 06EB    Insert  a  CC2538EM  board  into  the SmartRF06EB as shown above.  Caution! The kit contains ESD sensitive components.  Handle  with  care  to prevent  permanent  damage.  To minimize  risk  of  injury,  avoid  touching components  during  operation  if symbolized as hot. 5. Power Options  There are several ways of applying power to the TrxEB.    USB (5V)   2 x 1.5 V AAA batteries   1 x 3.0 V CR2032 coin cell battery   External regulated power supply  There  are  voltage  regulators  on  the SmartRF06EB that will set the on-board voltage to 2.1 V or 3.3 V.  Warning!  To  minimize  risk  of  injury or  property damage,  never  use  rechargeable  batteries  to power the board.  Always select a power source that is  suitably rated for use with this EVM,  not exceeding  3.6  VDC,  with  a  current  output rating between 0 and 500 mA. 6. Select Power Source        The  power source  is selected  using  the Source switch on the left hand side of the SmartRF06EB. In “USB” position, the EM is powered over USB, running  at  3.3  V.  In  “BAT”  position,  the  board is powered  from  batteries  or  an  external  source, running  at  2.1  V.  The  2.1  V  regulator  can  be bypassed by shorting the  pins  on  the “regulator bypass” jumper. In this case, the EM is powered directly from the external source or batteries.  Note  that  there  should  only  be  one  active power  source  at  any one  time.  Do  not  leave the EVM powered when unattended.  7. Welcome Screen    Turn on power with the Main Power switch. You should now see the Texas Instruments logo and a  short  description  of  the  buttons  on  the  LCD. Pushing any of the five buttons on the board will take you to the main menu.  NB!  If  you  don’t  see  anything  on  the  screen make  sure  the  board  is  correctly  powered (see step 5 and 6 above). 8. Select Channel    Select which channel to use for the test. 9. Select Mode  One of the boards must operate as a transmitter and the other as a receiver.  Select transmitter on one board …  … and receiver on the other board.    The receiver is now configured.   Buttons EM Connectors Micro SD card reader USB Main Power Switch Emulator LEDs LCD LEDs 10-pin ARM Debug Connector EM Breakout Power Selection 20-pin ARM-JTAG Connector
 10. Select TX Power    On the transmitter, select desired output power.  11. Select Burst Size    On the transmitter, select the desired burst size, that is, the number of packets to transmit. 12. Select Packet Rate    On the transmitter, select the desired packet rate.  13. Start Sending Packets  The  transmitter  is  now  configured  and  in  idle state.  Sending  packets  is  started/stopped  by pressing the Select button.     15. PER Test Results  On the receiver, the statistics window will show the error rate based on the number of lost or erreneous packets divided by the total number of packets that should have been received.   18. References  Please visit www.ti.com and   http://www.ti.com/tool/cc2538dk  On the  kit product  page,  you  will find  additional documentation,  links  to  updated  software examples  and  software  tools  like  SmartRF Studio.  You will also find a lot of information on the TI E2E forum at http://e2e.ti.com   We hope that you will enjoy working with the CC2538 device. 17. Troubleshooting  It you are experiencing problems with this test, please check the following:    Nothing  is  shown  in  the display!  Make  sure the board is  powered correctly (see steps  5 and 6 above).   Please  visit  the  kit web page and check  for updated  SW  and  documentation.  Updated SW can be downloaded to the device using IAR  EWARM  or  SmartRF  Flash Programmer.    SmartRF™ Studio  1. Download and Install    Before  connecting  SmartRF06EB  to  your  PC, download  and  install  SmartRF  Studio  from www.ti.com/smartrfstudio.  2. Launch SmartRF Studio    After installing the tool, connect the EB to the PC using  the  USB  cable  and  start  SmartRF  Studio. Select  the  “2.4  GHz”  tab  and  double  click  the highlighted CC2538 device icon. 3. Test the Radio    You  can  now  configure  the  radio,  run performance  tests, export register settings and run  link  tests  with  another  CC2538  on  a SmartRF06EB connected to the PC.
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS  Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions: The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT  OF  THE  INDEMNITY  SET  FORTH  ABOVE,  NEITHER  PARTY  SHALL  BE  LIABLE  TO  THE  OTHER  FOR  ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This  notice  contains  important safety information about temperatures and  voltages. For additional information on  TI's environmental and/or safety programs, please visit www.ti.com/esh or contact TI. No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein.  REGULATORY COMPLIANCE INFORMATION As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal Communications Commission (FCC) and Industry Canada (IC) rules. For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference.  General Statement for EVMs including a radio User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and power limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local laws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate this radio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited and unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory authorities, which is responsibility of user including its acceptable authorization.
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant  Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Interference Statement for Class B EVM devices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  For EVMs annotated as IC – INDUSTRY CANADA Compliant This Class B digital apparatus complies with Canadian ICES-003. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Concerning EVMs including radio transmitters This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Concerning EVMs including detachable antennas Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. ~ Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de l'utilisateur pour actionner l'équipement. Concernant les EVMs avec appareils radio Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Concernant les EVMs avec antennes détachables Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
 【Important Notice for Users of this Product in Japan】  This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan  If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:  1.  Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of Japan, 2.  Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this product, or 3.  Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan. Texas Instruments Japan Limited (address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan http://www.tij.co.jp   【ご使用にあたっての注意】  本開発キットは技術基準適合証明を受けておりません。  本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。    ( 1 ) 電波法施行規則第 6条第 1項第 1号に基づく平成 18 年3月28 日総務省告示第 173 号で定められた電波暗室等の試験設備でご使用いただく。    ( 2 ) 実験局の免許を取得後ご使用いただく。    ( 3 ) 技術基準適合証明を取得後ご使用いただく。 なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。 上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。  日本テキサス・インスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル http://www.tij.co.jp
 EVALUATION BOARD/KIT/MODULE (EVM) WARNINGS, RESTRICTIONS AND DISCLAIMERS For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end product. Your Sole Responsibility and Risk. You acknowledge, represent and agree that: 1.  You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees, affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes. 2.  You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates, contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard. 3.  You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail to perform as described or expected. 4. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.   Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures greater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found in development environments should use these EVMs. Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected. Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate Assurance and Indemnity Agreement. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated

Navigation menu