SWRU??? January 2013   Web sites:  www.ti.com/ble  E2E Forum:  www.ti.com/ble-forum    CC2541 Advanced Remote Control Quick Start Guide  Opening the Box and Evaluating Bluetooth® Low Energy Kit Contents     1 x Advanced Remote   1 x CC2540USB Dongle   1 x CC Debugger/Programmer   3 x AAA Battery    Documentation   The RF Boards in this kit are FCC and IC certified and  tested  to  comply  with  ETSI/R&TTE  over temperature from 0 to +35°C.    Caution!  The  kit  contains  ESD  sensitive components. Handle with care to prevent permanent damage.  Introduction  This  document  will  guide  you  through  the  initial steps required in order to run the pre programmed Bluetooth® low energy (BLE) demo application.  You will get familiar with the hardware in the box and  how  to  interface  the  remote  with  different platforms.  1. Evaluate  using  dongle.  A  USB  dongle pre-programmed  with firmware  acting  as translator  between  BLE  HID  and  USB HID is supplied in the kit and works with most operating system platforms.  2. Evaluate  using  Windows  8  native. Windows 8 includes native support for the BLE  HID  over  GATT  profile.  Using  a BT4.0 dongle or internal BT4.0 hardware you  can  easily  connect  the  Advanced Remote to your computer.   Hardware Setup  Insert  3xAAA  (LR03)  batteries  in  the  Advanced Remote’s battery holder. You are good to go.  Pressing  any  button  on  the  remote  will  put  it into advertising mode and make it detectable by Bluetooth Low Energy capable hosts. Connect Using Single Mode BT4.0 Low Energy CC2540USB HID Dongle 1. Insert dongle in USB port  The  dongle  will  be  enumerated  as  three  USB Human Interface Device class devices.    Mouse   Keyboard   Consumer control  The LED on the dongle should start blinking red, indicating  it’s  scanning  for  a  Bluetooth  Low Energy  peripheral  which  advertises  BLE  HID service capabilities. 2. Advertise and connect  Press any number key or consumer control key to make the device advertise.  The  devices  will  now  connect  and  pair  using JustWorks  pairing.  The  dongle  LED  should  now blink  green  when  data  is  received  from  the Advanced Remote and otherwise be off.  Long  term  bonding  entries  will  be  stored  in  both the  Advanced  Remote  and  dongle  to  speed  up subsequent reconnections. 3. Manage connection and bonds  Pressing  SW1  on  the  dongle  will disconnect  any active  connection  between  the  dongle  and  an Advanced Remote.  Pressing SW2 on the dongle  will  erase  all long  term  bond information stored on the dongle.  Pressing this button will not affect bond data stored on the Advanced Remote. Connect to Windows 8 with BT 4.0 LE (Smart Ready) hardware 1. Make sure LE works  In Device manager, under Bluetooth, make sure that you see references to Bluetooth LE.        2. Open PC settings  Move your mouse to the lower right hand corner and click on Settings.    Then click on Change PC settings.   3. Add Advanced Remote  Then click on Devices and Add a device.
4. Select and add the remote  If  you  have  pressed  a  button  on  the  Advanced Remote, and it’s not connected to another host, it will show up in the list of found devices.    5. Enter pairing code  The devices will now pair using Passkey entry. On your Advanced Remote, enter the 6-digit passkey displayed on the computer screen.    The Advanced Remote is now paired with Windows and bond data is stored on both devices, making reconnection faster and passkey entry unnecessary. 6. Remove device  A device can be removed from Windows and bond data deleted by clicking on the device and then the ( – ) symbol.   Using the Advanced Remote Control                              Mouse                 keys                                  Mouse speed                           Action keys 1. Advertise and connect  Almost all the keys will make the Advanced Remote start advertising and be discoverable by hosts scanning for HID capable BLE devices.  2. Keyboard input  Pressing any number will act as a keyboard input of that number. The same goes for OK which is Enter, Back which is Backspace and the four keys surrounding OK, which act as directional or arrow keys.  3. Consumer control  Buttons such as Volume, Mute, Play/Pause etc. are consumer control keys, and will control media settings on your computer. 4. Mouse input  Holding down the middle button will prompt the Advanced Remote to interpret your movement of the remote as mouse input and send this to the computer.  Double clicking the middle button will lock the mouse function. The left and right buttons act as left and right mouse buttons.  Pressing AV and –/– will decrease and increase mouse speed.  5. Remove bond information  Pressing the Red action button will remove bonding information stored on the Advanced Remote. Pairing will have to be done again, using passkey entry if applicable.  6. Calibrate  Pressing the Blue action button will force the Advanced Remote to recalibrate the onboard gyroscope and accelerometer used for motion sensing. Additional Tools and Links BLE Packet Sniffer  The CC2540 USB Dongle can be used as a BLE sniffer and monitor packets while the iPhone 4S Demo is running.    The  SmartRF  Protocol  Packet  Sniffer  software can be downloaded at www.ti.com/packetsniffer. SmartRF Flash Programmer  Texas Instruments has a simple tool which can be used to program and flash the CC2541.     SmartRF Flash Programmer can be downloaded at www.ti.com/tool/flash-programmer. IAR Embedded Workbench  To  develop  software,  program,  and  debug  the CC2541,  you  should  use  IAR  Embedded Workbench for 8051.     More  information on  IAR  EW8051,  including  a free evaluation version download, can be found at www.iar.com/ew8051. BLE E2E Forum  For  additional  help,  visit  the  TI  Bluetooth  low energy  E2E  forum,  www.ti.com/ble-forum,  for instant support during your development.   BLE Wiki  Our  BLE  Wiki  contains  application  examples, guides  and  documentation  covering  those  extra steps  you might need  help  with.  The Wiki  is not only  managed  by  Texas  Instruments  employees but  also  E2E  community  members.  Anyone  can share,  edit  and  make  use  of  the  information posted here.  The Wiki is found at www.ti.com/ble-wiki.  Useful Links  TI BLE Stack and Software: www.ti.com/ble-stack  CC2540/41 Mini Development Kit User Guide: www.ti.com/lit/swru270   CC2540/41 BLE Software Developer’s Guide: www.ti.com/lit/swru271   CC2540/41 User’s Guide: www.ti.com/lit/swru191   CC2541 Product Page: www.ti.com/cc2541
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS  Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions: The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO  BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT  OF  THE  INDEMNITY  SET  FORTH  ABOVE,  NEITHER  PARTY  SHALL  BE  LIABLE  TO  THE  OTHER  FOR  ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This notice contains  important  safety  information  about temperatures and voltages.  For additional information  on TI's environmental and/or safety programs, please visit www.ti.com/esh or contact TI. No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein.  REGULATORY COMPLIANCE INFORMATION As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal Communications Commission (FCC) and Industry Canada (IC) rules. For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference.  General Statement for EVMs including a radio User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and power limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local laws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate this radio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited and unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory authorities, which is responsibility of user including its acceptable authorization.
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant  Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Interference Statement for Class B EVM devices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  For EVMs annotated as IC – INDUSTRY CANADA Compliant This Class B digital apparatus complies with Canadian ICES-003. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Concerning EVMs including radio transmitters This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Concerning EVMs including detachable antennas Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. ~ Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de l'utilisateur pour actionner l'équipement. Concernant les EVMs avec appareils radio Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Concernant les EVMs avec antennes détachables Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
 【Important Notice for Users of this Product in Japan】  This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan  If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:  1.  Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of Japan, 2.  Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this product, or 3.  Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan. Texas Instruments Japan Limited (address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan http://www.tij.co.jp   【ご使用にあたっての注意】  本開発キットは技術基準適合証明を受けておりません。  本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。    ( 1 ) 電波法施行規則第 6条第 1項第 1号に基づく平成 18 年3月28 日総務省告示第 173 号で定められた電波暗室等の試験設備でご使用いただく。    ( 2 ) 実験局の免許を取得後ご使用いただく。    ( 3 ) 技術基準適合証明を取得後ご使用いただく。 なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。 上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。  日本テキサス・インスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル http://www.tij.co.jp
 EVALUATION BOARD/KIT/MODULE (EVM) WARNINGS, RESTRICTIONS AND DISCLAIMERS For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end product. Your Sole Responsibility and Risk. You acknowledge, represent and agree that: 1.  You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees, affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes. 2.  You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates, contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard. 3.  You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail to perform as described or expected. 4. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.   Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures greater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found in development environments should use these EVMs. Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected. Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate Assurance and Indemnity Agreement. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated