Thales e Transactions DATATAC001 Artema DataTAC POS Terminal User Manual covers

Thales e-Transactions, Inc. Artema DataTAC POS Terminal covers

ex9 manual

Download: Thales e Transactions DATATAC001 Artema DataTAC POS Terminal User Manual covers
Mirror Download [FCC.gov]Thales e Transactions DATATAC001 Artema DataTAC POS Terminal User Manual covers
Document ID169402
Application IDUSDJqoa/me1PAuUdEWOsbg==
Document Descriptionex9 manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.58kB (344808 bits)
Date Submitted2001-09-13 00:00:00
Date Available2001-11-09 00:00:00
Creation Date2001-08-22 14:15:05
Producing SoftwareAcrobat PDFWriter 4.0 for Windows
Document Lastmod2001-08-24 15:44:30
Document Titlecovers.PDF
Document CreatorMicrosoft Word
Document Author: artb

Consulting * Research * Training * Certification Testing Since 1981
FCC ID: PSMDATATAC001
Exhibit 9
User’s Manual
July 2001
APREL Project No.:
E-TRANSACTIONS, INC.
ARTEMA DataTAC
Installation Manual
July 24, 2001
Revision 1.0
ARTEMA DataTAC
Installation Manual
Table of contents
FCC STATEMENT............................................................................................................................................ 2
SAFETY ............................................................................................................................................................... 3
2.1
2.2
LITHIUM BATTERIES ......................................................................................................................................... 3
SAFETY INFORMATION ..................................................................................................................................... 3
ARTEMA OVERVIEW..................................................................................................................................... 4
INSTALLATION AND CONNECTIONS...................................................................................................... 5
4.1
4.2
4.3
4.4
4.5
ENVIRONMENT.................................................................................................................................................. 5
BATTERY PACK INSTALLATION ........................................................................................................................ 6
INSTALLING THE PAPER ROLL........................................................................................................................... 6
CONNECTING TO THE POWER SUPPLY .............................................................................................................. 8
CHARGING THE ARTEMA .............................................................................................................................. 8
TROUBLE SHOOTING & SPARE SPARTS ............................................................................................... 9
TECHNICAL SPECIFICATIONS................................................................................................................ 10
6.1
HANDSET SPECIFICATIONS ............................................................................................................................. 10
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
ARTEMA DataTAC
Installation Manual
1 FCC STATEMENT
Warning: Changes or modifications to this unit not expressly approved by Thales eTransactions could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Plug the equipment into an outlet on a circuit different from the one currently
being used.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: To prevent fire or shock hazard, and damage to your unit, do not expose
this terminal to rain or moisture.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL.
For your permanent records, we urge you to record the serial number of your
terminal in the space provided below. The serial number is located on the label
which can be found on the bottom of the unit.
Terminal Serial Number:
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
ARTEMA DataTAC
Installation Manual
2 SAFETY
2.1
Lithium batteries
In addition to the battery pack that powers the handset, Artema uses Lithium
batteries in order to backup internal data. The Lithium batteries in normal usage
conditions have a 6 year life expectancy. These batteries should only be replaced by
an approved service center.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the manufacturer.
Dispose of used batteries according
to the manufacturer’s instructions.
2.2
Safety Information
All Terminals:
• Avoid immersing the device in water
RF and DataTAC Terminals:
• Turn off the terminal in any area where radio transmissions are prohibitted
(such as fuel storage areas)
• Not intended to be used in a moving vehicle (may interfere with electronic fuel
injection, electronic anti-skid brakes, and electronic cruise control systems)
• May interfere with the functionality of inadequately protected medical devices,
including pacemakers (consult with physician or device manufacturer if you
have any questions)
• Do not use with a broken antenna
Warning: To comply with the FCC RF exposure requirements, this unit must be
operated with a minimum separation distance of 1 inch (2.4 cm) between the
antenna and a person's body.
Artema is an electrical device. It must be used under normal
conditions as described in this manual.
DO NOT OPEN THIS DEVICE. This device contains no user
serviceable parts. Service by non-authorized personnel may void the
warranty and could damage the unit and/or create a hazard.
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
ARTEMA DataTAC
Installation Manual
3 ARTEMA OVERVIEW
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
ARTEMA DataTAC
Installation Manual
4 INSTALLATION AND CONNECTIONS
4.1
Environment
In order to use Artema in optimal conditions
- Place the base on a clear, flat, leveled surface, close to the electrical outlet.
- Place the terminal away from excessive heat sources, vibrations, dust, water and
strong radio sources.
Environmental conditions
Operating temperature
Storage temperature
Relative humidity
Minimum
+41 °F (+5 °C)
-13 °F (-25 °C)
50%
Maximum
+104 °F (+40 °C)
+131 °F (+55 °C)
90%
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
4.2
ARTEMA DataTAC
Installation Manual
Battery pack installation
It is important to switch off the terminal before changing the battery pack.
Position the battery pack in the back of the handset.
Press on the upper part of the battery until a "click" noise is heard.
The terminal is ready for the charging cycle (see installation and connection).
4.3 Installing the paper roll
To obtain the highest printing quality, and to ensure maximum printer life span, only
use recommended paper rolls. (2 ¼” x 7/8” x 80’)
Open the printer casing by pressing simultaneously on both sides, and by pulling
upwards.
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
ARTEMA DataTAC
Installation Manual
Place the roll of paper in the casing, paper output towards the pin pad. Leave a
few inches of paper outside.
Close the printer casing. You will hear a "click" sound to confirm the casing is
closed.
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
4.4
ARTEMA DataTAC
Installation Manual
The printer will work only if the casing is closed.
Switch on the terminal, by pressing the "OK" key, and draw an inch of paper to
check that the roll is correctly placed in its casing.
Tear off the excess paper by pulling the paper towards the front of the terminal.
Connecting to the power supply
Plug the base power cord into a wall outlet (115V), and verify that the green
indicator light on the base is lit.
The outlet needs to be close to the terminal and within reach, in order to be
quickly disconnected, if necessary.
4.5
Charging The ARTEMA
Before using Artema for the first time, leave the handset on the base and let it
charge for 8 hours in order to fully charge the battery pack.
After a charging cycle, an icon on the terminal indicates the battery charge level
In order for you to run a large number of transactions without the base
We recommend that you change battery packs every two years.
Use only Thales certified battery packs.
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
ARTEMA DataTAC
Installation Manual
5 TROUBLE SHOOTING & SPARE SPARTS
Technical maintenance operations should only be done by approved servicing
centers.
However some problems can easily be solved:
Artema stops during display or printing:
Recharge the battery by placing the handset on the base for several hours.
Check that the battery is correctly inserted into the handset.
Check that the paper cover is completely closed.
The paper roll gets jammed:
Check that the paper roll is positioned correctly.
Check that the paper cover is completely closed.
Spare parts
To obtain extra batteries and paper rolls, contact Thales e-Transactions (toll free) at
(888) 710-0100.
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
ARTEMA DataTAC
Installation Manual
10
6 TECHNICAL SPECIFICATIONS
6.1
Handset specifications
Weight
Size
Printer
Display
Pin pad
Card readers
Central Processing Unit
Power supply
Autonomy
23.9 oz (680 g)
8.57 x 3.2 x 2.3 in (243 x 90 x 65 mm)
Thermal printer
Liquid Crystal Graphical, Back lit 40 x 132
11 alpha numeric keys, 3 navigation keys,
3 dedicated keys: CLR, CAN, ENT
Magnetic stripe card reader
ISO2 and ISO3 or ISO2 and ISO1
Optional smart card reader 8 or 16
contacts
ISO 7816 smart card readers : 2 or 4
optional SAM modules
32 bits RISC processor, 256 KB RAM
1 MB Flash memory
Removable battery pack
Charging time:
2 hours for 60% of capacity
8 hours for a full charge
Over 80 transactions
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.
Revision 1.0
ARTEMA DataTAC
Installation Manual
11
Notes
THIS INFORMATION IS PROPRIETARY INFORMATION OF THALES
e-TRANSACTIONS AND MAY NOT BE USED, COPIED, DISCLOSED
OR DIVULGED, IN WHOLE OR IN PART, FOR ANY PURPOSE BY
ANY PERSON WITHOUT THE WRITTEN APPROVAL OF THALES
e-TRANSACTIONS INC.
E-TRANSACTIONS, INC.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Creator                         : Microsoft Word
Create Date                     : 2001:08:22 14:15:05
Title                           : covers.PDF
Author                          : artb
Producer                        : Acrobat PDFWriter 4.0 for Windows
Modify Date                     : 2001:08:24 15:44:30-04:00
Page Count                      : 13
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PSMDATATAC001

Navigation menu