The Genie a Division of Overhead Door 315390R2 GARAGE DOOR REMOTE CONTROL RECEIVER User Manual 2060 3060 OWNERS MAN 1
The Genie Company a Division of Overhead Door Corporation GARAGE DOOR REMOTE CONTROL RECEIVER 2060 3060 OWNERS MAN 1
USERS MANUAL
2060-3060 eng.qxd 11/9/05 11:02 AM Page 1 Operation and Maintenance Manual 3559935770 ® 2060 3060 AC POWERED SCREW DRIVE OPENERS Warranty Information . . . . . . . . . . . . . . . . . . . 2 Your Documentation Package . . . . . . . . . . 3 Safety Information . . . . . . . . . . . . . . . . . . . . . 4 Safety Features . . . . . . . . . . . . . . . . . . . . . . . . . 4 Important Installation Instuctions . . . . . . . 4 Pre-Installation Checklist . . . . . . . . . . . . . . 5-8 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 Programming the Remote Control . . . . . 11 Installing lightbulb and lens. . . . . . . . . . . . 12 Scheduled Maintenance . . . . . . . . . . . . . . . 13 Troubleshooting Guide . . . . . . . . . . . . . 14-15 Wiring Diagram. . . . . . . . . . . . . . . . . . . . . . . . 16 Parts Lists and Exploded Views. . . . . . 17-18 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 COMPLETE WITH INTELLICODE REMOTE CONTROL AND SERIES II ELECTRONICS For up to 7'-6" tall Doors. (Extension Kit available for 8' Doors) Included Wall Control MUST be installed prior to Operation of this Garage Door Operator. Safe-T-Beam® Safety Reverse System Must be Installed and the Force Controls MUST be Properly Set to close door. This Equipment meets or exceeds all Federal, State and UL 325 Safety Requirements. Having Difficulty? Need Help? Please call us: 1-800-35-GENIE (354-3643) www.geniecompany.com Please have Model information ready when calling. SA FU E T TU HIS RE M RE AN FE UA RE L NC FO E R TABLE OF CONTENTS 2060-3060 eng.qxd 11/9/05 11:02 AM Page 2 THE GENIE COMPANY LIMITED WARRANTY 1.Do-It-Yourself-Service. What is covered? Any defect in material and product workmanship from personal, normal household use in accordance with the Owner’s Manual. For how long? MODEL 2060L . . . 20 years on motor, 3 years all other parts. MODEL 3060L . . . Lifetime* on motor, 3 years all other parts. MODEL 3060C . . . Lifetime* on motor, 3 years all other parts. *Lifetime = For as long as you own your home. Call the Genie Consumer Connection toll free at 1.800.354.3643 to speak in person to a trained Genie representative for assistance in diagnosing the problem and arranging to supply you with the required parts for do-it-yourself repairs.Trained service representatives are available Monday-Friday, 8:00 a.m. - 11:00 p.m., Eastern Time, and on Saturday, 10:00 a.m. to 7:00 p.m., Eastern Time (subject to holidays) You may also get the information you need at www.geniecompany.com. 2.Service From Authorized Dealers. Who gets the warranty? This warranty is limited to the consumer who originally purchased the product. Geographic scope: This warranty applies only to units installed and operated within the country where they were purchased. Limitations: IMPLIED WARRANTIES, INCLUDING THOSE OF FITNESS FOR A PARTICULAR PURPOSEAND MERCHANTABILITY (AN UNWRITTEN WARRANTY THAT THE PRODUCT IS FIT FOR ORDINARY USE), ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. GENIE WILL NOT PAY FOR: LOSS OF TIME; INCONVENIENCE;LOSS OF USE OF YOUR GENIE PRODUCT OR PROPERTY DAMAGE CAUSED BY YOUR GENIE PRODUCT OR ITS FAILURE TO WORK; ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES; OR ANY DAMAGES RESULTING FROM MISUSE OR MODIFICATION OF YOUR GENIE PRODUCT. Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty is the only one we will give on your Genie product, and it sets forth all our responsibilities regarding your Genie product.Therearenoother express warranties. State and province rights:This warranty gives you specific legal rights,and you may also have other rights which vary from state to state and province to province. How to get warranty service: To obtain warranty service for your Genie product, you must provide proof of the date and place of purchase of the product. You also may obtain warranty service from Genie authorized dealers by calling the Genie Customer Service at 1.800.354.3643 or by visiting www.geniecompany.com before scheduling warranty service. If warranty service is provided by an authorized dealer, Genie will provide all required parts under warranty at no charge to you, but the dealers are independent business people and may render a bench or service call charge for their services. Genie will not reimburse you or otherwise be responsible for those charges. We suggest that you retain your original packing material in the event we choose to repair or replaqce your Genie Product and request that you ship it to us. Be sure to include your name, address, telephone number, proof of date and place of purchase and a description of the operating problem. After repairing or replacing, your Genie product, we will ship it to your home at no cost to you for parts and labor, but you will have to pay a minimum of $5.00 for shipping and handling charges. Your choice of either one of the above-described service options is your exclusive remedy under this warranty. What this warranty does not cover: This warranty does not cover batteries (which are considered replaceable parts), installation, commercial use, defects resulting from accidents, damage while in transit to our service location or damage resulting from alterations, misuse or abuse, lack of proper maintenance, unauthorized repair or modification of the product,affixing of any attachment not provided with the product, programming of the Remote Control Devices, Safe-T-Beam® adjustment/cleaning, staples through wiring, pinched or broken wires, Carriage disengaged, Force Control adjustments, door out of balance, broken springs or cables, power outages, use of extension cords, missing or damaged parts on discounted, clearanced, final sale or taped cartons, phantom operations (labor is not covered if Opener is functioning properly while technician is in garage),fire, flood, or acts of God, or other failure to follow the Owner’s Manual. FOR ANSWERS: CALL 1.800.354.3643 Please note the following information,so it is available if you need to call us. Date Purchased ______________________________ Serial Number ______________________________ Operator Model ______________________________ Remote Control Model ______________________________ Model Number and Serial Number are located on front panel inside the lens. Dealer Name ______________________________ Dealer Address ______________________________ City ______________________________ State ______________________________ Zip ______________________________ NOTE Please keep original or photocopy of your sales receiptwith this manual for future reference should service ever be required. Visit Our Website at: www.geniecompany.com SAVE THESE INSTRUCTIONS For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 3 YOUR GARAGE DOOR OPENER DOCUMENTATION PACKAGE The documentation provided with your opener has been carefully designed and organized to make the assembly, operation, and continued maintenance of your product as easy and safe as possible. This material consists of two main items. Operation and Maintenance Manual While it is recommended that all documents be retained for future reference, this manual should contain most of the information that you will need over the lifetime of your product. The manual is designed in a “flip-flop” configuration with the english version in one half of the book and the spanish / french version in the other half. The basic contents of this manual are: English Language DASMA Spanish / French Language DASMA · Warranty Information · Pre Installation Checklist to be reviewed prior to any assembly or installation · Necessary Adjustments Tri-Lingual Entrapment label · Programming Remote Devices · Maintenance and Troubleshooting · Parts Explosions · Accessory Order Form · Door Opener Association Safety and Maintenance Brochure (DASMA) · Entrapment Warning Label - To be Adhered in close proximity to wall control English Language Version Spanish / French Language Version Assembly and Installation Poster This poster is intended to give a convenient lay flat media to be used at the site of assembly and installation. Color coding is used to highlight steps and other information as clearly as possible. This poster is Tri-Lingual with english instructions highlighted with a blue background. The basic contents of this Poster are: Opener Installation · Quick Reference Poster · Pictorial and step by step opener assembly instructions · Pictorial and step by step opener installation instructions Quick Reference Diagram Opener Assembly IT IS CRITICAL THAT ALL SAFETY WARNINGS MARKED CLEARLY IN BOTH THE MANUAL AND POSTER ARE READ, UNDERSTOOD AND FOLLOWED. The Genie Company is constantly striving to improve our products and the documentation that comes with them. If you have any suggestions or ideas for improving this product and it’s documentation, please forward them to: The Genie Company 22790 Lake Park Blvd. Alliance, Ohio 44601-3498 For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 4 SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS Overhead doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have questions or do not understand the information presented, call The Genie Company. or your local Genie Distributor. In this section, and those that follow, the words Danger, Warning and Caution are used to emphasize important safety information. The word: DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: indicates a potentially hazardous situation which, if not avoided, may result in injury or property damage. The word NOTE is used to indicate important steps to be followed or important considerations. POTENTIAL HAZARD PREVENTION EFFECT WARNING: Could result in death or serious injury. MOVING DOOR • Keep people clear of opening while door is moving. • Do Not allow children to play with the door operator. • Do Not operate a door that jams or one that has a broken spring. WARNING: Could result in death or serious injury. • Turn off power before removing operator cover. • When replacing cover, make sure wires are not pinched or near moving parts. • Operator must be properly grounded. WARNING: Could result in death or serious injury. • Do Not try to remove, repair or adjust springs or anything to which door spring parts are fastened, such as, wood blocks, steel brackets, cables or other like items. • Repairs and adjustments must be made by a trained door system technician using proper tools and instructions. ELECTRICAL SHOCK HIGH SPRING TENSION IMPORTANT INSTALLATION INSTRUCTIONS WARNING: TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. If you have any questions or do not understand an instruction, call your authorized Genie installation professional. Do Not install operator on an improperly balanced door. An improperly balanced door could cause severe injury. Repairs and adjustments to cables, spring assembly, and other hardware must be made by a trained service person using proper tools and instructions. Remove all ropes, and disable all locks connected to the door before installing operator. Install door operator 7 feet or more above the floor. Mount the emergency release knob 6 feet above the floor. Do Not connect the operator to the source of power until instructed to do so. Locate the control button: • Within sight of door. • At a minimum height of 5 feet, so small children cannot reach it. • Away from all moving parts of the door. Install the entrapment WARNING label next to the wall button or console. Install the emergency release tag on, or next to, the emergency release The operator must reverse when the door contacts a 1-1/2 inch high object on the floor at the center of the doorway. This is about the size of a 2" x 4" board laid flat. SAFETY FEATURES Safe-T-Beam® (STB) Non-Contact Reversing System Places an invisible beam across door opening, that reverses the door during down travel to the fully open position if anything passes through beam. Safe-T-Reverse® Contact Reversing System Automatically stops and reverses a closing door within 2 seconds of contact with an object. Safe-T-Stop® Timed Reversed System Automatically opens a closing door, if door does not close within 30 seconds. ForceGuard® Control Used to set the force required for opening and closing door. For maximum safety, set the minimum force required to fully open and close door. Automatic Lighting System Light bulbs up to 60 Watts max. , used for safer entries and exits. The lights turn on when door is activated and automatically turn off 4.5 minutes later. Manual Emergency Release Allows the garage door to be opened or closed manually for emergencies or maintenance. For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 5 PRE-INSTALLATION CHECKLIST WARNING: This Opener includes parts and supplies needed to install in most garages and connect to most garage doors. There are many variations of garages and garage doors. A few additional parts and supplies may be needed to install Opener into your garage and connect to your garage door. While checking items listed below, note any additional items you will need. If your door sticks, binds, or is out of balance, have it adjusted by a Genie Factory Authorized Dealer. Door springs, cables, pulleys, brackets and associated hardware are under extreme tension and can cause serious injury or death. Tools used in this section: • 12'+ Tape Measure • Pencil • Ladder • Level Check following items before assembling Opener: Check Step 1: CHECK DOOR CONDITION AND THICKNESS Check condition of vertical stile in center of door (Figure 2), and its connection to door’s top and bottom beams. A If door frame is nailed together and not a solid connection, door frame must be braced or reinforced before installing Opener. B If door is “lightweight” (made with frame and skin - not solid), door (including door frame) must be braced or reinforced before installing Opener. C A door opener reinforcement bracket may also be needed to connect garage door to Opener's Door Bracket. This Opener is designed for installation on a properly braced sectional door or solidly braced one-piece door. D Contact your Genie Factory Authorized Dealer or dealer of your garage door for any necessary bracing and a door opener reinforcement bracket (if needed) before proceeding. E If you have a wooden door, measure door’s thickness. (1/4" x 2") Lag Screws are included for installing Door Bracket onto door. If your door is less than 2” thick, brace door or use shorter Door Bracket Lag Screws (1/4" x 1-1/4" – not included) KEEP FEET CLEAR OF DOOR Check Step 2: CHECK GARAGE DOOR ALIGNMENT, OPERATION, AND BALANCE 3' - 4' Sectional Door 3' - 4' Raise door, check alignment and see if it moves freely (Figure 1). If door Figure 1 appears out of alignment, binds, or does not move smoothly, contact a Genie Factory Authorized Dealer or dealer of your garage door for repairs and adjustments to door mechanism. Raise door to 3' – 4' above ground and carefully let go. Door should stay stationary. Slight movement is acceptable. More than slight movement means door is out of balance. Contact a Genie Factory Authorized Dealer or dealer of SECTIONAL DOOR, TORSION SPRINGS SECTIONAL DOOR, EXTENSION SPRINGS your garage door for repairs and Extension Torsion adjustments to door Springs Springs Header mechanism. Area Center Check door type. Stile Make a note of whether it is a sectional or a Header one-piece door Area (Figure 2). One-Piece Door Checking door balance ONE-PIECE DOOR, TRACKLESS Header Area Center Stile Figure 2 For Help, call 1-800-35-GENIE or visit www.geniecompany.com Note Door Type 2060-3060 eng.qxd 11/9/05 11:02 AM Page 6 Check Step 3: MEASURE GARAGE DOOR HEIGHT Rail Extension for 8' door Measure garage door height (7'-6", 8'-0", or taller) with tape measure. A If door height is 7'-6" or less, continue with Check Step 4. B If door height is 8'-0", you need a Rail Extension Kit. (Figure 3) (See Accessories Order Form, page 19). C If door height is taller than 8'-0", you will require a different rail. Contact an Genie Customer Service Representative at 1-80035-GENIE. Figure 3 Rail Extension Kit Check Step 4: CHECK DOOR HEADER AREA NOTE SECTIONAL DOOR The header is a heavily reinforced section of the wall just above the top of the garage door opening. A Find vertical center line of door and header: • Close door. • Measure door width at top. • Mark a point at center of door and on header directly above door. Draw a center line to connect points. B Find Header Bracket mounting height (Figure 4): (Do not attach Header Bracket). • Raise door, watching top edge of door and stop door when its edge reaches its highest point. • Measure distance (“H”) from top edge of door to floor. – For sectional doors, add 2-1/2" to “H”. Mark a point on center line. Bottom of Header Bracket will be installed here. – For one-piece doors, add 6" to “H”. Mark this point on center line. Bottom of Header Bracket will be installed here. H + 2-1/2” HEADER ONE-PIECE DOOR NOTE • • For both types of doors: – If the ceiling in your garage is so low that there is not at least a 3" space above the Header Bracket mounting point, contact a Genie Factory Authorized Dealer. If a door spring is in the way, place the Header Bracket above the spring. Do Not move the door spring. H + 6” HEADER WARNING: Door springs are under extremely high tension and should be handled ONLY by a trained professional. Figure 4 Find Highest Point of Travel Check wall for a stud or a solid header at your mark: (If checking a finished wall, a stud finder may be helpful). • If location is above Header, a 2" x 6" board must be screwed to studs beside your mark with at least two Lag Screws and Flat Washers (not provided). • Transfer your mark to new mounting board. For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 7 Check Step 5: CHECK POWER HEAD MOUNTING AREA Check ceiling or space above where Opener Power Head will be mounted (Figure 5): A Measure from garage door center line mark toward rear of garage: • Approximately 10' back if garage has a 7' 6" door. • Approximately 11' back if garage has an 8' 0" door. Check for 15 Amp, 120 Volt grounded outlet or wiring box within 3 feet of Power Head. 10' for 7-1/2' doors 11' for 8' doors NOTE Since garage construction varies widely, there may be hardware required in addition to the mounting straps. Find location of ceiling joist or truss above where Opener Power Head will be and estimate type and quantity of materials needed for your installation (Figure 6). MOUNTING EXAMPLES Perforated Angle Iron Conduit Wood 30 30 30 55 11 55 11 Figure 5 Check Power Head location Perforated Straps FINISHED CEILINGS Locate ceiling joists or trusses using a stud finder or similar device. Attach angle iron (not included) to joists or trusses through finish material using Lag Screws. OPEN CEILINGS Straps and angle iron may attach directly to joists or trusses. Figure 6 Mounting methods for open beam or finished ceilings Check Step 6: CHECK CEILING FOR GROUNDED POWER SOURCE Check that there is a 15 Amp 120 Volt grounded electrical outlet or grounded permanent wiring box (per building code) within 3' of Opener Power Head: • If not, an outlet or wiring box must be installed. Contact a licensed electrician for installation. • If building codes require permanent wiring, Power Head must be partially disassembled to install appropriate wiring in place of Power Cord (See Installation Poster). NOTE Permanent wiring must be installed by a Licensed Electrician. Not all Genie Factory Authorized Dealers are Licensed Electrician's. Contact someone who is a Licensed Electrician. For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 8 Check Step 7: CHECK SAFE-T-BEAM® MOUNTING BRACKET LOCATION Check for wood garage frame, jamb, or masonry at mounting location (6" above floor) with attachment tabs facing away from garage door (Figure 7). Source If you cannot mount Safe-T-Beam® Mounting Bracket to wood frame: • Concrete screws and concrete anchors (not included) must be used to mount Brackets on masonry with attachment tabs facing away from garage door. • Safe-T-Beam® Mounting Bracket Extensions may be used (not included - available from a Genie Factory Authorized Dealer or through Accessories Order Form on page 19). Sensor Safe-T-Beam® Mounting Bracket Check Step 8: RECOMMENDED TOOLS Tools (Figure 8): Additional tools to make installation easier: • Slotted and phillips screw-driver bits • Stud finder • Sheet-metal cutting snips 6" Top of Bracket 6" above floor Figure 7 Mounting Safe-T-Beam® Components Check Step 9: REMOVE EXISTING GARAGE DOOR LOCKS Check that the garage door locks, rope, and T-Handles are removed from the garage door before starting the installation. Before going further, get any items and tools needed for your installation Safe-T-Beam® Sensor Mounting Bracket Extensions (dealer) Garage door opener reinforcement bracket (dealer) Garage door frame reinforcement brackets, screws, bracing or reinforcement kits (dealer) Lag Screws (1-1/4") for a wood door less than 2" thick (store) Electrical outlet and/or wiring (supplied by a licensed electrician) Sufficient angle iron or strapping for hanging Power Head (store) 60 Watt light bulbs (Rough service bulbs recommended)(store) GER-2 Emergency Release Kit for entry during power failure (store) Wood for header, ceiling, and/or door bracing reinforcement (if needed) Masonry fasteners for Safe-T-Beam® Bracket installation, (if needed) Masonry drill bit (if needed) Extension Kit (for 8' garage doors) Electric Drill If your garage does not have a separate entry door, it is highly recommended to install a Genie Emergency Release Kit (GER-2). Emergency Release Kit lets you open garage door from outside if there is a power failure. (Please see Accessories Order Form on page 19.) 1/16" 5/32" Drill Bit Drill Bit 6' or 7' Step Ladder 12' + Tape Measure Adjustable Wrench Wire Stripper Hammer Pliers Phillips Screwdriver Socket Wrench Safety Glasses Flat Blade Screwdriver Pencil Hack Saw 1/4" 5/16" 3/8" 7/16" 1/2" 9/16" Sockets Carpenter's Level Figure 8 Recommended Tools For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 9 MAINTENANCE AND ADJUSTMENTS Adjustment 1: CH SET LIMIT SWITCHES AND FORCE CONTROLS Rough Setting of Limit Switches Setting Close Limit Switch (Figure 9): • Check that Carriage Assembly is disengaged. • With garage door fully closed, slide Close Limit Switch toward Carriage until white lever is fully lifted. • Tighten Set Screw. Do Not over-tighten. Setting Open Limit Switch: • Manually open garage door to full open position. • Slide Open Limit Switch toward Carriage until white lever is fully lifted. • Tighten Set Screw. Do not over-tighten. • Re-engage Carriage Assembly. NOTE • • • • Little effort is required to turn the Force Adjusting Knobs. If the door stops moving while opening or closing, adjust the Open Force or Close Force Controls slightly clockwise (to slightly increase the force) and retry the step. The Open Force and Close Force Controls are to be set to the minimum force necessary to ensure the door smoothly opens and closes completely. Ensure the Carriage Assembly is engaged and is between the two Limit Switches before operating the Opener. Setting Force Controls and Final Adjustment of Limit Switches WARNING • • • • The garage door opens rapidly, and can cause serious injury or death. Keep the path clear. Position the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door. Set the door Opener to use the minimum force needed to open the door. CLOSE ADJUSTMENT • On front panel of Power Head find adjusting screw marked “CLOSE” (Figure 9). • Gently turn screw counterclockwise until it stops. – Very little force is required to turn adjusting screw. • Press Wall Console to close garage door. – Observe if door stops at “CLOSE” limit switch. If door is fully closed—adjustment is finished. Go to “OPEN” Adjustment. – If door stops but is not fully closed, a. Measure distance between bottom of door and floor. b. Move “CLOSE” Limit Switch that same distance toward door. – If door stops and/or reverses before reaching the “CLOSE” Limit Switch a. Slightly increase CLOSE Force setting (clockwise). – If door reverses after contacting floor, move Limit Switch toward Power Head. – If door fails to move, check Safe-T-Beam® System. See Troubleshooting Section, page 14. • Tighten Limit Switch Set Screw. Do not over-tighten (strip) Limit Switch Set Screw. FORCE CONTROLS CLO SE OP EN CLO SE OPE Figure 9 Making Force Adjustments Open adjustment next page. For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 10 Setting Force Controls and Final Adjustment of Limit Switches (continued) WARNING • • • • A moving grage door can cause serious injury or death. Keep the path clear. Position the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door. Set the door Opener to use the minimum force needed to open the door. OPEN ADJUSTMENT • On front panel of Power Head find adjusting screw marked “OPEN” (Figure 9). • Gently turn screw counterclockwise until it stops. – Very little force is required to turn adjusting screw. • Press Wall Console to close garage door. – Observe if door stops at “OPEN” limit switch. If door is fully open—adjustment is finished. – If door stops but is not fully open, a. Measure distance between bottom of door top of door opening. b. Move “OPEN” Limit Switch that same distance toward Power Head. – If door stops before reaching the “OPEN” Limit Switch a. Slightly increase OPEN Force setting (clockwise). – If door fails to move, see Troubleshooting Section, pages 15. Run Door Opener • Cycle opener a few times to double check settings. Repeat adjustment steps as necessary. Adjustment 2: CH SETTING CONTACT REVERSE FUNCTION NOTE Limit Switch and Force Adjustments must be completed before checking the contact reverse function (Figure 10 ). Open garage door using Wall Console. Lay a 2" x 4" board flat in center of doorway. Close door using Wall Console. Check that door stops and reverses within 2 seconds after it contacts board: • If door does not reverse, decrease Close Force until door reverses. • If door still does not reverse, move Limit Switch toward door. Check Safe-T-Beam® System operation: • If beam is blocked, door will not close. NOTE 2" x 4" board laid flat Figure 10 Checking Contact Reverse The door must contact the 2" x 4" board before the Carriage activates the Close Limit Switch. If not,readjust the Close Limit Switch. 10 For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 11 ACCESSORIES C PROGRAMMING THE Programming 1: REMOTE CONTROLS NOTE • • • • • • Each Remote Control must be programmed separately. The Remote Controls will not cause the door Opener to close the garage door if the Safe-TBeam® System is malfunctioning. When programming the Remote Controls, they must be at least 24" from the Antenna Wire. If the red Learn Indicator Light blinks approximately 4 times per second, programming has stopped. If programming has stopped, repeat the above steps. Each Button on a 2 or 3 Button Remote Control is for a different Opener. You cannot use more than one Button per Remote, per Opener. A maximum of seven Remote Controls or Wireless Keypads can be stored into the Receiver at one time. If a Remote Control becomes lost, or if you want to delete a Remote Control or Wireless Keypad, see “To Erase All Receiver Memory.” To program one Button of a Remote Control (Figure 12): • Locate Learn Button and Learn Indicator Light near Terminal Strip on Power Head (Figure 13). • Press and release Learn Button. Red Learn Indicator Light will blink 2 times per second. • Press Remote Control Button once within 30 seconds. Red Learn Indicator Light will stay lit. • Press Remote Control Button again. Red Learn Indicator Light will go out, indicating that memory is stored. Program each additional Remote using step A above (up to seven). WARNING A moving garage door may cause serious injury or death. • Keep people clear of opening while door is moving. • Do not allow children to play with the Remote Controls. If the Safety Reverse does not work properly: • Close the door and disconnect the Opener using the Emergency Release Cord. • Do not use the door Opener, Remote Controls, or Wireless Keypad. • Refer to the door and door Opener Owner’s Manuals before attempting any repairs. Remote Control Operation Press Button on Remote Control. Garage door will move. Press Button again. Garage door will stop: • The door automatically stops at the end of the open or close cycle. Press Button again. Garage door will reverse. Press and hold Learn Button on Power Head for 10 seconds or until Learn Indicator Light goes out. Memory is erased: • Program Transmitter/Receiver again as needed. To Replace Remote Control Battery FOR NON-FLASHLIGHT MODELS • Pop off the back of the transmitter. – Use coin, pen, screwdriver or any similar device. – Replace old Battery with new coin type battery. • Replace back of remote. FOR FLASHLIGHT MODELS • Slide open battery cover. – Replace old Battery with new AAA battery. • Replace battery cover. 315 Mhz Frequency Switch 390 Mhz 390 Mhz 1 Button Compact Remote 3 Button Compact Remote w/Docking Station w/Docking Station Figure 12 Genie Remote Controls 1 2 3 4 Figure 13 Learn Code Button and Indicator Light To Erase All Remotes from Power Head Memory 315 Mhz Frequency Switch Some Remote Controls are equipped with a flashlight. The logo is the button which operates the light. There is a backlight under the button. When it does not light, it indicates the battery needs replaced. Frequency Switch Flashlight Button 1 Button Remote w/Flashlight 3 Button Remote w/Flashlight 3 Button Large Remote w/Flashlight Figure 14 Genie Remote Controls For Help, call 1-800-35-GENIE or visit www.geniecompany.com 11 2060-3060 eng.qxd 11/9/05 11:02 AM Page 12 ABOUT DUAL FREQUENCY REMOTE TRANSMITTERS Transmitter Compliance Statement Your garage door opener (GDO) features a unique dual frequency remote control system for reliable service in today’s crowded airwaves. Overcrowded airwaves may intermittently interfere with GDO’s remote control system. The dual frequency feature greatly reduces the possibility of unwanted interference. The receiver in the GDO’s powerhead can receive signals at 315 AND 390 MHz. The remote is factory set at 315 MHz. See Figure 12 on page 11 for frequency selector switch. Switch your remote control frequency when: • Remote does not have adequate range. • Remote works inconsistently with fresh battery installed - LED feedback lights up when pressing button. • Programming your car’s HomeLink® system. To program a HomeLink® device: (This GDO is HomeLink® compatible.) • Use a small flat screwdriver to switch the frequency selector to 390 MHz. • Follow the HomeLink® instructions in your car owner’s manual. • Reset the remote control frequency to 315 MHz for everyday use. INSTALL LIGHT BULBS AND LENS A Install two 60 Watt light bulbs (not included) into Light Sockets (Figure 13): • Rough service, 130 Volt bulbs are recommended. B Hold the lens, with the bottom hinges pointing up, against the power head metal front cover (Figure 14). • Insert (2) #8-32 x 3/8”Phillips Hex Head Screws through the Bottom hinges and into holes provided in metal front cover of Power Head (Figure 14). Tighten screws. • Flip Lens up and fasten with (2) #8-32 x 3/8”Phillips Pan Head Screws where indicated. Figure 13 Install Lightbulbs 12 Figure 14 Attach Lens For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 13 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ AND FOLLOW ALL INSTRUCTIONS. Never let children operate or play with the Door Controls. Keep the Remote Control away from children. Always keep the moving door in sight and away from people and objects until the door is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. Test Opener monthly. The door MUST reverse on contact with a 1-1/2" high object (or a 2" x 4" board laid flat) at the center of the doorway on the floor. After adjusting either the Force or the Limit of travel, retest the Door Opener. Failure to adjust the Opener properly may cause severe injury or death. When possible use the Emergency Release only when the door is closed. Use caution when using this Release with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death. KEEP GARAGE DOORS PROPERLY BALANCED. See garage door Owner's Manual. An improperly balanced door increases the risk of severe injury or death. Have a Genie Factory Authorized Dealer make repairs to cables, spring assemblies, and other hardware. SAVE THESE INSTRUCTIONS. MAINTENANCE A Monthly: • Door springs and door hardware: – Oil door roller, bearings, and hinges using silicone lubricant or light oil. WARNING Do not operate door automatically or manually if springs are broken. Contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE. • Balance Door. – Close door. – Release Carriage Assembly from Rail Assembly by pulling the Emergency Release Knob towards the door. – Raise door manually 3'- 4' and verify that door stays at that position. See Check Step 2 on page 5. NOTE When the door is 3' - 4' above the ground, the door should stay open. Slight movement is acceptable. If the door moves too much, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE. • – Reattach Carriage Assembly to Rail Assembly: a. Pull the Emergency Release Knob toward Power Head. b. Close door. Contact Reverse Test. – Perform Adjustment 2 on page 10. WARNING If the door fails to reverse on contact with the board, adjust the Close Force Control as specified in Set Limit Switches and Force Controls on page 10. If the Opener still fails, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE. B Yearly: • Wipe off old excess lubricant from Drive Screw. • Lubricate Drive Screw with Genie Lubricant (GLU-3) NOTE Use ONLY Genie Lubricant (GLU-3). Other lubricants may damage the Opener. GLU-3 Lubricant WARNING Use the Wall Console included with Opener. Any other wall console can cause the Opener to operate unexpectedly and the light to stop working. age e Gar icant w Driv Lubr Scre OpenerU-3 Door rt No. GL Pa FCC AND IC CERTIFIED All devices comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. C As needed • Replace lightbulbs. For Help, call 1-800-35-GENIE or visit www.geniecompany.com 13 2060-3060 eng.qxd 11/9/05 11:02 AM Page 14 TROUBLESHOOTING Safe-T-Beam® System Self-Diagnostic Troubleshooting Source (Red LED) ON Sensor (Green LED) ON OFF OFF OFF ON 2 BLINKS, Pause (Repeat) ON 2 BLINKS, Pause (Repeat) 3 BLINKS, Pause (Repeat) 4 BLINKS, Pause (Repeat) 14 OFF ON ON Possible Problem Normal operation • Power Head not powered • Wiring from Power Head bad Solution None required • Check breakers, fuses, plugs • Check wiring for obvious shorts • • • • • • • • • • • • • • • • • Wiring to Source missing or bad Power has been interrupted Beam not aligned Beam obstructed Sensor defective Wire to Sensor missing or bad Sensor defective Sensor receiving interference • Source not sending pulses • Source defective Check wiring Remove power and reapply Check Source, Sensor alignment Check for obstruction Contact Customer Service Check wiring Contact Customer Service Determine source of interference Check for interference from sunlight or a source unit on an adjacent door • Contact Customer Service • Contact Customer Service • Contact Customer Service For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 15 General Troubleshooting Problem Opener does not run from Wall Control Door Opener starts for no apparent reason Door starts down, then stops before it is completely closed Door starts down, then stops and goes back up Door will only run closed Door will only run open Lights will not turn off Door starts up, but stops before it is completely open Operator runs, but door does not move Wall Console Vacation Lock function does not work Noisy Operation What To Do 1. Check Lock switch on Wall Control (see Wall Console section on Installation Poster). 2. Check Power Source: • For Grounded Plug Connection. – Plug a lamp into the electrical outlet used for the door opener. a. If lamp lights, power source is good. b. If lamp does not light, check fuse or circuit breaker. • For Permanent Wiring Connection. – Check fuse or circuit breaker. 3. Check connections (see Wall Console section on Installation Poster): • At Power Head Terminals and Wall Control. 1. Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires) Replace any shorting Staples and shorted Wires. 2. Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory and reprogram for remaining remote controls. (See Erase All Receiver Memory on page 11). 3. Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls. 1. Check Close Limit Switch setting (page 9 and Installation Poster). Adjust as needed. 2. Check Force Setting (page 9). Adjust as needed. 3. Check for shorted wires. 1. If a new installation, check Door Arm position. 2. Check operation of Contact Reverse function. 3. Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses. 4. Check Safe-T-Beam® System diagnostic code. 5. Check Close Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. 6. Check garage door for binding. 1. Check Open Limit Switch for a short circuit and for proper wiring. 2. Check Open Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. 3. Check condition of garage door and door spring(s). 4. WARNING: If you suspect a problem with the garage door hardware or springs,contact a Genie Factory Authorized Dealer for service,or contact Customer Service at 1-800-35-GENIE. 5. Check position of Lock Switch on Console. 1. Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart (page 14). 2. Check Close Limit Switch for a short circuit and for proper wiring. 3. Check Close Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. 1. Disconnect Wires connecting Wall Console to Power Head (see “Wall Console Installation”-on Installationposter). Check their condition and either replace or reconnect. 2. Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls or Wireless Keypad to operate Opener. 3. Check for non-compatible wall control. 1. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly balanced as detailed in Maintenance Section. 2. WARNING: If you suspect a problem with the garage door hardware or springs,contact a Genie Factory Authorized Dealer for service,or contact Customer Service at 1-800-35-GENIE. 3. Check Open Limit Switch for a short circuit and for proper wiring. 4. Check Open Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. 1. Ensure Carriage Assembly is engaged to Rail Drive Screw (see Install Carriage Assembly -INSTALLATION POSTER). 2. Check Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed. 3. Check that all sections of Rail Drive Screw are turning when Motor runs. If not: • Check condition (not cracked, split, or broken) and placement of Coupler. Replace as needed. • Check condition (not cracked, split, or broken) and placement of Collar and Clip. Replace them as needed. 1. Ensure Carriage Assembly is in contact with Close Limit Switch. 2. Check when door is fully closed, that Carriage activates Close Limit Switch. If not, adjust position of Close Limit Switch (See page 9). 1. Be sure all fasteners are tight. 2. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly balanced as described in Maintenance Section (page 13). For Help, call 1-800-35-GENIE or visit www.geniecompany.com 15 2060-3060 eng.qxd 11/9/05 11:02 AM Page 16 WIRING DIAGRAM WARNING Opening Cover May Cause Electric Shock POWER CORD WHITE WHITE WHITE GREEN BLACK OPEN WHITE GREEN CLOSE ORANGE PRIMARY SEQUENCER BLACK THERMAL PROTECTOR LIGHTS BLACK RED / WHITE 11 BLUE MOTOR PRIMARY 10 BLUE 12 RED GREY PURPLE GREEN ORANGE ORANGE YELLOW SECONDARY TRANSFORMER YELLOW (Vcc) ORANGE MOTOR CAPACITOR RED (Vcc) ORANGE (SIGNAL) SEQUENCER HOUSING (TRIP) RADIO CONNECTOR 10 11 GREEN 12 13 16 17 16 (COMMAND) GREY OPEN BROWN CLOSE GREEN 15 (STB SYSTEM) 14 RPM SENSOR GREEN WHITE WALL CONTROL STRIPED STRIPED STB SYSTEM WHITE TERMINAL STRIP For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 17 PARTS IDENTIFICATION POWER HEAD [1] Power Head Assembly 41 48 49 42 39 Power Head Parts List Item 39 41 42 48 49 Part Name Power Head Assembly Cover (by Series Model) Front Plate Assembly Light Socket Motor Parts Receiver Assembly Capacitor (By Series/Model) Opto Wheel Opto-Luctor Assembly Sequencer Assembly Circuit Board Bracket Transformer Terminal Strip No. 8-32 x 1/2" Hex Head Screw w/Lockwasher No. 8-32 x 3/8" Slot Hex Head Screw w/Lockwasher Capacitor Isolator 1/4-20 Shoulder Bolt 1/4" Flange Nut Coupler No. 8-32 x 3/8" Phillips Hex Head Screw No. 8-32 x 3/8" Phillips Pan Head Screw Mounting Straps Light Lens For Help, call 1-800-35-GENIE or visit www.geniecompany.com Number Included 17 2060-3060 eng.qxd 11/9/05 11:02 AM Page 18 PARTS IDENTIFICATION RAIL [3] 16 15A Rail Assembly 44 11 12 3A 39 3B 22 15B 10 24 3C 20 25 28 46 23 17 47 24 13 22 18 25 27 26 21 Parts List (cont’) Item 3A 3B 3C 10 11 12 13 15A 15B 16 17 18 19 20 21 22 23 24 25 26 27 28 18 Part Name Power Head Assembly (see page 5) Rail Assembly (3-piece) First Rail Section Middle Rail Section End Rail Section 1/4”-20 Hex Head Shoulder Bolt 1/4”-20 Hex Flange Nut Carriage Stop Rail Clamps 5/16” Hex Head Shoulder Bolt 5/16” Hex Flange Nut Carriage Assembly Collar Retaining Clip Rail Strap Open Limit Switch Assembly (grey) Close Limit Switch Assembly (brown) #8-32 x 3/8” Hex Head Screw Emergency Release Cord Emergency Release Knob Emergency Release Tag (not shown) Header Bracket Door Bracket 1/4” x 2” Lag Screw Straight Door Arm Clevis Pin Cotter Pin Curved Door Arm 3/8” x 7/8” Hex Head Bolt 3/8” Hex Flange Nut Number Included 13 Parts List (cont’) Item 29 30 31 33 34 35 36 37 38 39 40 41 42 43 44 46 47 48 49 50 Part Name Wire (not shown) Insulated Staples (not shown) Wall Button (not shown) Wall Console (not shown) #6 x 1-1/4” Pan Head Screw Entrapment WARNING Label (not shown) Safe-T-Beam (STB)Sensor (green LED) (not shown Safe-T-Beam Source (red LED) (not shown) Safe-T-Beam Bracket (not shown) Coupler #10 x 1-1/4” Phillips Hex Head Screw #8 x 3/8” Hex Head Screw #8 x 3/8” Pan Head Screw Safety and Maintenance Guide (not shown) Wire Clip 5/16” x 3/4” Hex Head Bolt 1/4”-20 x 3/4” Self-tapping Screw Mounting Straps Light Lens (see page 5) Remote Control (not shown) Number Included ~ 95 ft ~ 30 varies varies varies For Help, call 1-800-35-GENIE or visit www.geniecompany.com 2060-3060 eng.qxd 11/9/05 11:02 AM Page 19 Garage Door Opener Accessories Order Form Formulario de pedido de accesorios para abridores de puertas de garaje Formulaire de commande des accessoires pour ouvre-porte de garage ® How many? ¿Quántos? Comment beaucoup? For additional accessories not shown. visit our website at www.geniecompany.com Para accesorios adicionalesno mostrada, visite nuestro sitio web en www.geniecompany.com pour les accessoires supplémentaires pas montré, visiter notré site web à www.geniecompany.com (GI CTD-1) 1-Button Compact Remote - Allows remote operation of garage door. Comprima el Mando de Distancia - Proporciónar operación remoto de la puerta del garaje. Télécommande compacte - Permettre opération éloign´´de porte de garage. P/N 35674R $36.50 (GI F TD-1) 1-Button Flashlight Transmitter - Remote Controller with a Flashlight. 1 abrocha transmisor de linterna - Director remoto con una linterna. 1-boutenner l’émetteur de lampe de poche - Le contrôleur éloigné avec de lampe de poche. P/N 35657R $45.00 $50.00 (GWC-2W) Deluxe Wall Console - Operates Garage Door. Independent light control. Security vacation lock. Consola de lujo de pared - Acciona la puerta del garaje. Control de luz independiente. Cerradura de seguridad para vacaciones. La Console dse luxe de Mur - Actionne la porte de garage. Commande d’éclairage indépendante. Interrupteur de verrouillage de sécurité. P/N 35661R $35.00 ABC DEF GHI JKL MNO PQRS TUV WXYZ 9V Screw Drive Garage Door Opener Lubricant Part No. GLU-3 (GW-2) Universal Wall Button - Provides additional convenient inside operation of door. $3.75 (GPS-5) Perfect Stop - Ensures perfect parking. ® Stop Perfecto® - Asegura el estacionamiento perfecto. Butoir Perfect Stop® - Permet de stationner à la perfection dans le garage. P/N 35677R $4.00 (GABX8) QuietLift Extension Kit - An Extension that increases the travel of an Opener to accommodate an eight foot door. Juego de extensión de cadena deslizable - Una extensión para aumentar la longitud de la baranda de Chain Glide, para acomodar una puerta de 8 pies (2,43 m). Nécessaire de prolongement du coulisseau - Rallonge de prolongeant la course de l’ouvre-porte Chain Glide pour une porte de 2,4 m (8 pi) de hauteur. P/N 35663R $32.00 $32.00 $32.00 $2.73 For Help, call 1-800-35-GENIE or visit www.geniecompany.com SHIPPING & HANDLING STATE SALES TAX GRAND TOTAL 5.00 No se aceptan pedidos de pago contra entrega (COD). Sírvase incluir su cheque o giro postal, la cuenta pagadera hecha aThe Genie Company. No envíe dinero en efectivo. Concédanos 3 a 4 semanas para la entrega. 1-800-354-3643. Sírvase tener listos los números del modelo y de la tarjeta de crédito. Enviar hacer un pedido de mercancia a: Genie Company, 22790 Lake Park Blvd, Alliance, Ohio 44601.Aceptamos pedidos telefónicos de Visa o Mastercard. Sírvase agregar el impuesto de ventas local si usted reside en uno de los siguientes estados: California, Connecticut, Florida, Georgia, Illinois, Indiana, Maryland, Massachusetts, Michigan, New Jersey, New York, Ohio, Tennessee, Virginia, Wisconsin TOTAL DEL PEDIDO FLETE Y MANEJO IMPUESTO DE VENTAS ESTATAL GRAN TOTAL 5.00 Pas d’expédition contre remboursement. Veuillez inclure un chèque ou un mandat bancaire, le payable fait à The Genie Company. N’envoyez pas d’argent comptant. Accordez de 3 à 4 semaines pour la livraison. 1-800-354-3643. Ayez sous la main le numéro de la pièce et celui de la carte de crédit. Mettre à la poste le arrngement à: Genie Company, 22790 Lake Park Blvd, Alliance, Ohio 44601. Nous acceptons les commandes par téléphone avec paiement par carte de crédit Visa ou Mastercard. California, Connecticut, Florida, Georgia, Illinois, Indiana, Maryland, Massachusetts, Michigan, New Jersey, New York, Ohio, Tennessee, Virginia, Wisconsin COMMANDE TOTALE MANUTENTION ET EXPÉDITION TAXE DE VENTE TOTAL GLOBAL 5.00 SHIP ORDER TO: ENVIAR MERCANCIA CON: EXPÉDIER MARCHANDISE POUR: NAME / NOMBRE / NOM ADDRESS / DIRECCIÓN / ADRESSE $20.00 STB Adapter Brackets (2) - Used in conjunction with standard STB Brackets.They provide additional clearance and mounting options. El adaptador pone entre paréntesis (2) - Usado en unión con paréntesis uniformes de montar de STB, ellos proporcionan el espacio libre adicional junto con mortar las opciones. Crochets d’adaptateur (2) - Utilisé conjointement avec STB standard monter les crochets, ils fournissent le dégagement supplémentaire avec monter d’options. P/N 34439R.S Veuillez indiquer les taxes de vente locales si vous résidez dans l’un des états répertoriés ci-dessous. (GSX-8) DirectLift Extension Kit - An Extension to increase travel of an Operator to accommodate eight foot door. Juego de extensión deslizante de Screw Drive - Una extensión para aumentar la carrera de un abridor deslizable, para acomodar una puerta de 8 pies (2,43 m.). Nécessaire de rallonge du Screw Drive - Rallonge de prolongeant la coursede l’ouvre-porte pour une porte de 2,4 m (8 pi) de hauteur.(GIRU-1T) P/N 35678R (60 WATT) Enhanced/Rough Service Light Bulb - Ensures proper equipment compatability. Bombilla de 60 Vatios - Asegura componente correcto de sistema. Éclairage de 60 WATT - Garantir componant exact par systéme. P/N 26210A.S (GER-2) Emergency Release Kit - Provides access to garage from outside in the event of an electrical power failure. Juego de pica-porte de pestillo - Permitir entrtada desde por fuera de garaje porque corte de eléctrico. Nécessaires de Déclenchement de secours - Le nécessaire de déclenchement de secours est conçupour vous permettre d’accéder à votre garage depuis P/N 35675R l’extérieur en cas de panne de courant et lorsqu’il. TOTAL ORDER Instructions Commandant (LCGX-8) ChainLift Extension Kit - An Extension that increases the travel of an Opener to accommodate an eight foot door. Juego de extensión de cadena deslizable - Una extensión para aumentar la longitud de la baranda de Chain Glide, para acomodar una puerta de 8 pies (2,43 m). Nécessaire de prolongement du coulisseau - Rallonge de prolongeant la course de l’ouvre-porte Chain Glide pour une porte de 2,4 m (8 pi) de hauteur. P/N 35679R California, Connecticut, Florida, Georgia, Illinois, Indiana, Maryland, Massachusetts, Michigan, New Jersey, New York, Ohio, Tennessee, Virginia, Wisconsin Las Instrucciones que Ordenan (GWKPD) Dual Frequency Wireless Keypad - Operates Intellicode® Garage Door Openers without Remote Control or key. Sistema de entrada por teclado numérico inalámbrico - Acciona los abridores de puertas de garaje Intellicode® sin control remoto o llave. Système d’ouvre-porte de garage à clavier sans fil - Actionne les ouvre-porte de garage avec Intellicode® sans télécommande ni clé. P/N 35691R $50.00 (GLU-3) 3/4 oz. Screw Drive Lubricant - Ensures proper equipment wear protection. 3/4 once Lubricante de tornillo accionar - Asegura componente correcto protección por deterioro. La onza 3/4 Lubricant de la vis - Garantir componant exact par systéme défense vers user. P/N 35218AS $5.00 Botón de pared universal - Proporciona operación conveniente de la puerta desde el interior. Bouton mural universel - Actionne l’ouvre-porte de l’intérieur du garage. P/N 35693R No C.O.D. shipments. Please include check or money order, made payable to The Genie Company. Do not send cash. Allow 3-4 weeks for delivery. 1-800-354-3643. Please have part number and credit card ready. Mail Order Form to: Genie Company, 22790 Lake Park Blvd, Alliance, Ohio 44601. We accept Visa or Mastercard on phone orders only. Please add local sales tax if you reside in one of the states listed. (GI CTD-3) 3-Button Compact Remote - Allows remote operation of 3 garage doors. De 3 botones Comprima el Mando de Distancia - Proporciónar operación remoto de tres las puertas del garaje. 3-boutenner la Télécommande compacte - Permettre opération éloign´ trois portes P/N 35694S de garage. Ordering Instructions CITY / CIUDAD / VILLE STATE / ESTADO / ÉTAT ZIP / CÓDIGO POSTAL / CODE POSTAL $4.37 (Prices subject to change without notice) (Valoran el cambio con sujeción a sin nota) (Les prix assujettissent pour changer sans la notification) 19 2060-3060 eng.qxd 20 11/9/05 11:02 AM Page 20 For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Create Date : 2005:11:09 11:02:35Z Creator Tool : QuarkXPress(tm) 6.5 Modify Date : 2005:11:11 07:21:37-05:00 Metadata Date : 2005:11:11 07:21:37-05:00 Producer : QuarkXPress(tm) 6.5 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (PANTONE 2665 U).%%+ (C100K10).%%RGBCustomColor: .303 .33 .703 (PANTONE 2665 U).%%+ .007 .564 .698 (C100K10).%%EndComments Format : application/pdf Title : 2060-3060 OWNERS MAN-1.qxd Document ID : uuid:d54583be-51e3-11da-b41f-0050e445647e Instance ID : uuid:b51d39df-52ad-11da-b41f-0050e445647e Has XFA : No Page Count : 20 Creator : QuarkXPress(tm) 6.5EXIF Metadata provided by EXIF.tools