The Genie a Division of Overhead Door 315390R2 GARAGE DOOR REMOTE CONTROL RECEIVER User Manual 2060 3060 OWNERS MAN 1

The Genie Company a Division of Overhead Door Corporation GARAGE DOOR REMOTE CONTROL RECEIVER 2060 3060 OWNERS MAN 1

USERS MANUAL

Download: The Genie a Division of Overhead Door 315390R2 GARAGE DOOR REMOTE CONTROL RECEIVER User Manual 2060 3060 OWNERS MAN 1
Mirror Download [FCC.gov]The Genie a Division of Overhead Door 315390R2 GARAGE DOOR REMOTE CONTROL RECEIVER User Manual 2060 3060 OWNERS MAN 1
Document ID623841
Application IDMRd8E7ATR5a9N8y2d3bdtg==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize209.62kB (2620307 bits)
Date Submitted2006-01-27 00:00:00
Date Available2006-01-25 00:00:00
Creation Date2005-11-09 11:02:35
Producing SoftwareQuarkXPress(tm) 6.5
Document Lastmod2005-11-11 07:21:37
Document Title2060-3060 OWNERS MAN-1.qxd
Document CreatorQuarkXPress(tm) 6.5

2060-3060 eng.qxd
11/9/05
11:02 AM
Page 1
Operation and
Maintenance Manual
3559935770
®
2060
3060
AC POWERED SCREW DRIVE OPENERS
Warranty Information . . . . . . . . . . . . . . . . . . . 2
Your Documentation Package . . . . . . . . . . 3
Safety Information . . . . . . . . . . . . . . . . . . . . . 4
Safety Features . . . . . . . . . . . . . . . . . . . . . . . . . 4
Important Installation Instuctions . . . . . . . 4
Pre-Installation Checklist . . . . . . . . . . . . . . 5-8
Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . 9-10
Programming the Remote Control . . . . . 11
Installing lightbulb and lens. . . . . . . . . . . . 12
Scheduled Maintenance . . . . . . . . . . . . . . . 13
Troubleshooting Guide . . . . . . . . . . . . . 14-15
Wiring Diagram. . . . . . . . . . . . . . . . . . . . . . . . 16
Parts Lists and Exploded Views. . . . . . 17-18
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
COMPLETE WITH INTELLICODE
REMOTE CONTROL AND SERIES II
ELECTRONICS
For up to 7'-6" tall Doors. (Extension Kit available for 8' Doors)
Included Wall Control MUST be installed prior to Operation of
this Garage Door Operator.
Safe-T-Beam® Safety Reverse System Must be Installed and
the Force Controls MUST be Properly Set to close door.
This Equipment meets or exceeds all Federal, State and UL 325
Safety Requirements.
Having Difficulty? Need Help?
Please call us: 1-800-35-GENIE (354-3643)
www.geniecompany.com
Please have Model information
ready when calling.
SA
FU E T
TU HIS
RE M
RE AN
FE UA
RE L
NC FO
E R
TABLE OF CONTENTS
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 2
THE GENIE COMPANY LIMITED WARRANTY
1.Do-It-Yourself-Service.
What is covered?
Any defect in material and product workmanship from personal, normal household use
in accordance with the Owner’s Manual.
For how long?
MODEL 2060L . . . 20 years on motor, 3 years all other parts.
MODEL 3060L . . . Lifetime* on motor, 3 years all other parts.
MODEL 3060C . . . Lifetime* on motor, 3 years all other parts.
*Lifetime = For as long as you own your home.
Call the Genie Consumer Connection toll free at 1.800.354.3643 to speak in person to a
trained Genie representative for assistance in diagnosing the problem and arranging
to supply you with the required parts for do-it-yourself repairs.Trained service representatives are available Monday-Friday, 8:00 a.m. - 11:00 p.m., Eastern Time, and on
Saturday, 10:00 a.m. to 7:00 p.m., Eastern Time (subject to holidays) You may also get
the information you need at www.geniecompany.com.
2.Service From Authorized Dealers.
Who gets the warranty?
This warranty is limited to the consumer who originally purchased the product.
Geographic scope:
This warranty applies only to units installed and operated within the country where
they were purchased.
Limitations:
IMPLIED WARRANTIES, INCLUDING THOSE OF FITNESS FOR A PARTICULAR PURPOSEAND
MERCHANTABILITY (AN UNWRITTEN WARRANTY THAT THE PRODUCT IS FIT FOR ORDINARY USE), ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. GENIE WILL NOT
PAY FOR: LOSS OF TIME; INCONVENIENCE;LOSS OF USE OF YOUR GENIE PRODUCT OR
PROPERTY DAMAGE CAUSED BY YOUR GENIE PRODUCT OR ITS FAILURE TO WORK; ANY
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES; OR ANY DAMAGES RESULTING
FROM MISUSE OR MODIFICATION OF YOUR GENIE PRODUCT.
Some states and provinces do not allow limitations on how long an implied warranty
lasts or the exclusion of incidental or consequential damages, so the above limitations or
exclusions may not apply to you.
This warranty is the only one we will give on your Genie product, and it sets forth all our
responsibilities regarding your Genie product.Therearenoother express warranties.
State and province rights:This warranty gives you specific legal rights,and you may also
have other rights which vary from state to state and province to province.
How to get warranty service:
To obtain warranty service for your Genie product, you must provide proof of the date
and place of purchase of the product.
You also may obtain warranty service from Genie authorized dealers by calling the
Genie Customer Service at 1.800.354.3643 or by visiting www.geniecompany.com
before scheduling warranty service. If warranty service is provided by an authorized
dealer, Genie will provide all required parts under warranty at no charge to you, but
the dealers are independent business people and may render a bench or service call
charge for their services. Genie will not reimburse you or otherwise be responsible for
those charges.
We suggest that you retain your original packing material in the event we choose to
repair or replaqce your Genie Product and request that you ship it to us. Be sure to
include your name, address, telephone number, proof of date and place of purchase
and a description of the operating problem. After repairing or replacing, your Genie
product, we will ship it to your home at no cost to you for parts and labor, but you will
have to pay a minimum of $5.00 for shipping and handling charges.
Your choice of either one of the above-described service options is your exclusive
remedy under this warranty.
What this warranty does not cover:
This warranty does not cover batteries (which are considered replaceable parts), installation, commercial use, defects resulting from accidents, damage while in transit to our
service location or damage resulting from alterations, misuse or abuse, lack of proper
maintenance, unauthorized repair or modification of the product,affixing of any attachment not provided with the product, programming of the Remote Control Devices,
Safe-T-Beam® adjustment/cleaning, staples through wiring, pinched or broken wires,
Carriage disengaged, Force Control adjustments, door out of balance, broken springs
or cables, power outages, use of extension cords, missing or damaged parts on discounted, clearanced, final sale or taped cartons, phantom operations (labor is not covered if Opener is functioning properly while technician is in garage),fire, flood, or acts of
God, or other failure to follow the Owner’s Manual.
FOR ANSWERS: CALL 1.800.354.3643
Please note the following information,so it is available if you
need to call us.
Date Purchased ______________________________
Serial Number ______________________________
Operator Model ______________________________
Remote Control Model ______________________________
Model Number and
Serial Number are
located on front
panel inside
the lens.
Dealer Name ______________________________
Dealer Address ______________________________
City ______________________________
State ______________________________
Zip ______________________________
NOTE
Please keep original or photocopy of your sales
receiptwith this manual for future reference should
service ever be required.
Visit Our Website at: www.geniecompany.com
SAVE THESE INSTRUCTIONS
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 3
YOUR GARAGE DOOR OPENER DOCUMENTATION PACKAGE
The documentation provided with your opener has been carefully designed and organized to make the assembly, operation, and continued
maintenance of your product as easy and safe as possible. This material consists of two main items.
Operation and Maintenance Manual
While it is recommended that all documents be retained for future reference, this manual should contain most of the information that you
will need over the lifetime of your product. The manual is designed in a “flip-flop” configuration with the english version in one half of the
book and the spanish / french version in the other half. The basic contents of this manual are:
English Language
DASMA
Spanish / French
Language DASMA
· Warranty Information
· Pre Installation Checklist to be reviewed prior to any
assembly or installation
· Necessary Adjustments
Tri-Lingual
Entrapment label
· Programming Remote Devices
· Maintenance and Troubleshooting
· Parts Explosions
· Accessory Order Form
· Door Opener Association Safety and Maintenance Brochure (DASMA)
· Entrapment Warning Label - To be Adhered in close proximity
to wall control
English Language
Version
Spanish / French
Language Version
Assembly and Installation Poster
This poster is intended to give a convenient lay flat media to be used at the site of assembly and installation. Color coding is used to
highlight steps and other information as clearly as possible. This poster is Tri-Lingual with english instructions highlighted with a blue
background. The basic contents of this Poster are:
Opener Installation
· Quick Reference Poster
· Pictorial and step by step opener assembly instructions
· Pictorial and step by step opener installation instructions
Quick Reference
Diagram
Opener Assembly
IT IS CRITICAL THAT ALL SAFETY WARNINGS MARKED CLEARLY IN BOTH
THE MANUAL AND POSTER ARE READ, UNDERSTOOD AND FOLLOWED.
The Genie Company is constantly striving to improve our products and the documentation that comes with them. If you have any
suggestions or ideas for improving this product and it’s documentation, please forward them to:
The Genie Company
22790 Lake Park Blvd.
Alliance, Ohio 44601-3498
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 4
SAFETY INFORMATION
OVERVIEW OF POTENTIAL HAZARDS
Overhead doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under
tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have
questions or do not understand the information presented, call The Genie Company. or your local Genie Distributor.
In this section, and those that follow, the words Danger, Warning and Caution are used to emphasize important safety
information. The word:
DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: indicates a potentially hazardous situation which, if not avoided, may result in injury or property damage.
The word NOTE is used to indicate important steps to be followed or important considerations.
POTENTIAL HAZARD
PREVENTION
EFFECT
WARNING:
Could result in death
or serious injury.
MOVING DOOR
• Keep people clear of opening while door is moving.
• Do Not allow children to play with the door operator.
• Do Not operate a door that jams or one that has a broken spring.
WARNING:
Could result in death
or serious injury.
• Turn off power before removing operator cover.
• When replacing cover, make sure wires are not pinched or near
moving parts.
• Operator must be properly grounded.
WARNING:
Could result in death
or serious injury.
• Do Not try to remove, repair or adjust springs or anything to
which door spring parts are fastened, such as, wood blocks,
steel brackets, cables or other like items.
• Repairs and adjustments must be made by a trained door
system technician using proper tools and instructions.
ELECTRICAL SHOCK
HIGH SPRING TENSION
IMPORTANT INSTALLATION
INSTRUCTIONS
WARNING:
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH:
READ AND FOLLOW ALL SAFETY, INSTALLATION AND
OPERATION INSTRUCTIONS. If you have any
questions or do not understand an instruction, call
your authorized Genie installation professional.
Do Not install operator on an improperly balanced
door. An improperly balanced door could cause
severe injury. Repairs and adjustments to cables,
spring assembly, and other hardware must be made
by a trained service person using proper tools and
instructions.
Remove all ropes, and disable all locks connected to
the door before installing operator.
Install door operator 7 feet or more above the floor.
Mount the emergency release knob 6 feet above
the floor.
Do Not connect the operator to the source of power
until instructed to do so.
Locate the control button:
• Within sight of door.
• At a minimum height of 5 feet, so small children
cannot reach it.
• Away from all moving parts of the door.
Install the entrapment WARNING label next to the
wall button or console. Install the emergency release
tag on, or next to, the emergency release
The operator must reverse when the door contacts a
1-1/2 inch high object on the floor at the center of
the doorway. This is about the size of a 2" x 4" board
laid flat.
SAFETY FEATURES
Safe-T-Beam® (STB) Non-Contact Reversing System
Places an invisible beam across door opening, that reverses
the door during down travel to the fully open position if
anything passes through beam.
Safe-T-Reverse® Contact Reversing System
Automatically stops and reverses a closing door within 2
seconds of contact with an object.
Safe-T-Stop® Timed Reversed System
Automatically opens a closing door, if door does not close
within 30 seconds.
ForceGuard® Control
Used to set the force required for opening and closing
door. For maximum safety, set the minimum force required
to fully open and close door.
Automatic Lighting System
Light bulbs up to 60 Watts max. , used for safer entries and
exits. The lights turn on when door is activated and
automatically turn off 4.5 minutes later.
Manual Emergency Release
Allows the garage door to be opened or closed manually
for emergencies or maintenance.
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 5
PRE-INSTALLATION CHECKLIST
WARNING:
This Opener includes parts and supplies needed to install in most garages and
connect to most garage doors. There are many variations of garages and garage
doors. A few additional parts and supplies may be needed to install Opener into
your garage and connect to your garage door. While checking items listed
below, note any additional items you will need.
If your door sticks, binds, or is out of
balance, have it adjusted by a Genie Factory
Authorized Dealer. Door springs, cables,
pulleys, brackets and associated hardware
are under extreme tension and can cause
serious injury or death.
Tools used in this section:
• 12'+ Tape Measure
• Pencil
• Ladder
• Level
Check following items before assembling Opener:
Check Step 1: CHECK DOOR CONDITION AND
THICKNESS
Check condition of vertical stile in center of door (Figure 2), and its connection
to door’s top and bottom beams.
A If door frame is nailed together and not a solid connection, door frame
must be braced or reinforced before installing Opener.
B If door is “lightweight” (made with frame and skin - not solid), door
(including door frame) must be braced or reinforced before
installing Opener.
C A door opener reinforcement bracket may also be needed to connect
garage door to Opener's Door Bracket. This Opener is designed for
installation on a properly braced sectional door or solidly braced
one-piece door.
D Contact your Genie Factory Authorized Dealer or dealer of your garage
door for any necessary bracing and a door opener reinforcement
bracket (if needed) before proceeding.
E If you have a wooden door, measure door’s thickness. (1/4" x 2") Lag
Screws are included for installing Door Bracket onto door. If your door
is less than 2” thick, brace door or use shorter Door Bracket Lag
Screws (1/4" x 1-1/4" – not included)
KEEP FEET CLEAR OF DOOR
Check Step 2: CHECK GARAGE DOOR
ALIGNMENT, OPERATION,
AND BALANCE
3' - 4'
Sectional Door
3' - 4'
Raise door, check alignment and see if it moves freely (Figure 1). If door
Figure 1
appears out of alignment, binds, or does not move smoothly, contact a
Genie Factory Authorized Dealer or dealer of your garage door for repairs
and adjustments to door mechanism.
Raise door to 3' – 4' above ground and carefully let go. Door should stay
stationary. Slight movement is acceptable. More than slight movement
means door is out of balance. Contact a Genie Factory Authorized
Dealer or dealer of
SECTIONAL DOOR, TORSION SPRINGS SECTIONAL DOOR, EXTENSION SPRINGS
your garage door
for repairs and
Extension
Torsion
adjustments to door
Springs
Springs
Header
mechanism.
Area
Center
Check door type.
Stile
Make a note of
whether it is a
sectional or a
Header
one-piece door
Area
(Figure 2).
One-Piece Door
Checking door balance
ONE-PIECE DOOR, TRACKLESS
Header Area
Center Stile
Figure 2
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Note Door Type
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 6
Check Step 3: MEASURE GARAGE DOOR HEIGHT
Rail Extension for
8' door
Measure garage door height (7'-6", 8'-0", or taller) with
tape measure.
A If door height is 7'-6" or less, continue with Check Step 4.
B If door height is 8'-0", you need a Rail Extension
Kit. (Figure 3) (See Accessories Order Form, page 19).
C If door height is taller than 8'-0", you will require a different rail.
Contact an Genie Customer Service Representative at 1-80035-GENIE.
Figure 3
Rail Extension Kit
Check Step 4: CHECK DOOR HEADER AREA
NOTE
SECTIONAL DOOR
The header is a heavily reinforced section of the wall just
above the top of the garage door opening.
A Find vertical center line of door and header:
• Close door.
• Measure door width at top.
• Mark a point at center of door and on header directly
above door. Draw a center line to connect points.
B Find Header Bracket mounting height (Figure 4):
(Do not attach Header Bracket).
• Raise door, watching top edge of door and stop door
when its edge reaches its highest point.
• Measure distance (“H”) from top edge of door to floor.
– For sectional doors, add 2-1/2" to “H”. Mark a point
on center line. Bottom of Header Bracket will be
installed here.
– For one-piece doors, add 6" to “H”. Mark this point on
center line. Bottom of Header Bracket will be
installed here.
H + 2-1/2”
HEADER
ONE-PIECE DOOR
NOTE
•
•
For both types of doors:
– If the ceiling in your garage is so low that there is
not at least a 3" space above the Header Bracket
mounting point, contact a Genie Factory
Authorized Dealer.
If a door spring is in the way, place the Header
Bracket above the spring. Do Not move the door spring.
H + 6”
HEADER
WARNING:
Door springs are under extremely high tension and should be
handled ONLY by a trained professional.
Figure 4
Find Highest Point of Travel
Check wall for a stud or a solid header at your mark:
(If checking a finished wall, a stud finder may be helpful).
• If location is above Header, a 2" x 6" board must be
screwed to studs beside your mark with at least two Lag
Screws and Flat Washers (not provided).
• Transfer your mark to new mounting board.
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 7
Check Step 5: CHECK POWER HEAD
MOUNTING AREA
Check ceiling or space above where Opener Power Head will be
mounted (Figure 5):
A Measure from garage door center line mark toward rear
of garage:
• Approximately 10' back if garage has a 7' 6" door.
• Approximately 11' back if garage has an 8' 0" door.
Check for 15 Amp, 120 Volt
grounded outlet or wiring box
within 3 feet of
Power Head.
10'
for 7-1/2' doors
11'
for 8' doors
NOTE
Since garage construction varies widely, there may be
hardware required in addition to the mounting straps.
Find location of ceiling joist or truss above where Opener
Power Head will be and estimate type and quantity of
materials needed for your installation (Figure 6).
MOUNTING EXAMPLES
Perforated Angle Iron
Conduit
Wood
30
30
30
55 11
55 11
Figure 5 Check Power Head location
Perforated Straps
FINISHED CEILINGS
Locate ceiling joists or trusses
using a stud finder or similar
device.
Attach angle iron (not included)
to joists or trusses through
finish material using Lag Screws.
OPEN CEILINGS
Straps and angle iron may attach
directly to joists or trusses.
Figure 6 Mounting methods for open beam or finished ceilings
Check Step 6: CHECK CEILING FOR GROUNDED
POWER SOURCE
Check that there is a 15 Amp 120 Volt grounded electrical
outlet or grounded permanent wiring box (per building code)
within 3' of Opener Power Head:
• If not, an outlet or wiring box must be installed. Contact
a licensed electrician for installation.
• If building codes require permanent wiring, Power Head
must be partially disassembled to install appropriate
wiring in place of Power Cord (See Installation Poster).
NOTE
Permanent wiring must be installed by a Licensed
Electrician. Not all Genie Factory Authorized Dealers are
Licensed Electrician's. Contact someone who is a Licensed
Electrician.
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 8
Check Step 7: CHECK SAFE-T-BEAM®
MOUNTING BRACKET LOCATION
Check for wood garage frame, jamb, or masonry at mounting location
(6" above floor) with attachment tabs facing away from garage door
(Figure 7).
Source
If you cannot mount Safe-T-Beam® Mounting Bracket to
wood frame:
• Concrete screws and concrete anchors (not included)
must be used to mount Brackets on masonry with
attachment tabs facing away from garage door.
• Safe-T-Beam® Mounting Bracket Extensions may be used
(not included - available from a Genie Factory Authorized
Dealer or through Accessories Order Form on page 19).
Sensor
Safe-T-Beam®
Mounting Bracket
Check Step 8: RECOMMENDED TOOLS
Tools (Figure 8):
Additional tools to make installation easier:
• Slotted and phillips screw-driver bits
• Stud finder
• Sheet-metal cutting snips
6"
Top of
Bracket 6"
above
floor
Figure 7 Mounting Safe-T-Beam® Components
Check Step
9: REMOVE EXISTING GARAGE
DOOR LOCKS
Check that the garage door locks, rope, and T-Handles are removed
from the garage door before starting the installation.
Before going further, get any items and tools
needed for your installation
Safe-T-Beam® Sensor Mounting Bracket Extensions (dealer)
Garage door opener reinforcement bracket (dealer)
Garage door frame reinforcement brackets, screws, bracing
or reinforcement kits (dealer)
Lag Screws (1-1/4") for a wood door less than 2" thick (store)
Electrical outlet and/or wiring (supplied by a
licensed electrician)
Sufficient angle iron or strapping for hanging Power Head
(store)
60 Watt light bulbs
(Rough service bulbs recommended)(store)
GER-2 Emergency Release Kit for entry during power failure
(store)
Wood for header, ceiling, and/or door bracing reinforcement
(if needed)
Masonry fasteners for Safe-T-Beam® Bracket installation,
(if needed)
Masonry drill bit (if needed)
Extension Kit (for 8' garage doors)
Electric
Drill
If your garage does not have a separate entry door, it is highly
recommended to install a Genie Emergency Release Kit (GER-2).
Emergency Release Kit lets you open garage door from outside if
there is a power failure. (Please see Accessories Order Form on
page 19.)
1/16"
5/32"
Drill Bit Drill Bit
6' or 7'
Step Ladder
12' +
Tape Measure
Adjustable Wrench
Wire
Stripper
Hammer
Pliers
Phillips Screwdriver
Socket
Wrench
Safety Glasses
Flat Blade Screwdriver
Pencil
Hack Saw
1/4" 5/16" 3/8" 7/16" 1/2" 9/16"
Sockets
Carpenter's Level
Figure 8 Recommended Tools
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 9
MAINTENANCE AND ADJUSTMENTS
Adjustment 1: CH
SET LIMIT SWITCHES AND
FORCE CONTROLS
Rough Setting of Limit Switches
Setting Close Limit Switch (Figure 9):
• Check that Carriage Assembly is disengaged.
• With garage door fully closed, slide Close Limit Switch
toward Carriage until white lever is fully lifted.
• Tighten Set Screw. Do Not over-tighten.
Setting Open Limit Switch:
• Manually open garage door to full open position.
• Slide Open Limit Switch toward Carriage until white lever
is fully lifted.
• Tighten Set Screw. Do not over-tighten.
• Re-engage Carriage Assembly.
NOTE
•
•
•
•
Little effort is required to turn the Force
Adjusting Knobs.
If the door stops moving while opening or
closing, adjust the Open Force or Close Force
Controls slightly clockwise (to slightly
increase the force) and retry the step.
The Open Force and Close Force Controls are to
be set to the minimum force necessary to
ensure the door smoothly opens and
closes completely.
Ensure the Carriage Assembly is engaged and is
between the two Limit Switches before
operating the Opener.
Setting Force Controls and Final Adjustment of
Limit Switches
WARNING
•
•
•
•
The garage door opens rapidly, and can cause serious
injury or death.
Keep the path clear.
Position the ladder to the side of the Power Head so it is
clear of all moving parts of the Opener and the door.
Set the door Opener to use the minimum force needed
to open the door.
CLOSE ADJUSTMENT
• On front panel of Power Head find adjusting screw
marked “CLOSE” (Figure 9).
• Gently turn screw counterclockwise until it stops.
– Very little force is required to turn adjusting screw.
• Press Wall Console to close garage door.
– Observe if door stops at “CLOSE” limit switch.
If door is fully closed—adjustment is finished.
Go to “OPEN” Adjustment.
– If door stops but is not fully closed,
a. Measure distance between bottom of door
and floor.
b. Move “CLOSE” Limit Switch that same distance
toward door.
– If door stops and/or reverses before reaching the
“CLOSE” Limit Switch
a. Slightly increase CLOSE Force setting (clockwise).
– If door reverses after contacting floor, move Limit
Switch toward Power Head.
– If door fails to move, check Safe-T-Beam® System. See
Troubleshooting Section, page 14.
• Tighten Limit Switch Set Screw. Do not over-tighten
(strip) Limit Switch Set Screw.
FORCE
CONTROLS
CLO
SE
OP
EN
CLO
SE
OPE
Figure 9 Making Force Adjustments
Open adjustment next page.
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 10
Setting Force Controls and Final Adjustment of
Limit Switches (continued)
WARNING
•
•
•
•
A moving grage door can cause serious injury or death.
Keep the path clear.
Position the ladder to the side of the Power Head so it is
clear of all moving parts of the Opener and the door.
Set the door Opener to use the minimum force needed
to open the door.
OPEN ADJUSTMENT
• On front panel of Power Head find adjusting screw
marked “OPEN” (Figure 9).
• Gently turn screw counterclockwise until it stops.
– Very little force is required to turn adjusting screw.
• Press Wall Console to close garage door.
– Observe if door stops at “OPEN” limit switch.
If door is fully open—adjustment is finished.
– If door stops but is not fully open,
a. Measure distance between bottom of door
top of door opening.
b. Move “OPEN” Limit Switch that same distance
toward Power Head.
– If door stops before reaching the “OPEN” Limit Switch
a. Slightly increase OPEN Force setting (clockwise).
– If door fails to move, see Troubleshooting Section,
pages 15.
Run Door Opener
• Cycle opener a few times to double check settings.
Repeat adjustment steps as necessary.
Adjustment 2: CH
SETTING CONTACT
REVERSE FUNCTION
NOTE
Limit Switch and Force Adjustments must be completed
before checking the contact reverse function (Figure 10 ).
Open garage door using Wall Console.
Lay a 2" x 4" board flat in center of doorway.
Close door using Wall Console.
Check that door stops and reverses within 2 seconds after it
contacts board:
• If door does not reverse, decrease Close Force until
door reverses.
• If door still does not reverse, move Limit Switch
toward door.
Check Safe-T-Beam® System operation:
•
If beam is blocked, door will not close.
NOTE
2" x 4" board
laid flat
Figure 10 Checking Contact Reverse
The door must contact the 2" x 4" board before the Carriage activates
the Close Limit Switch. If not,readjust the Close Limit Switch.
10
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 11
ACCESSORIES
C PROGRAMMING THE
Programming 1:
REMOTE CONTROLS
NOTE
•
•
•
•
•
•
Each Remote Control must be programmed
separately.
The Remote Controls will not cause the door
Opener to close the garage door if the Safe-TBeam® System is malfunctioning.
When programming the Remote Controls, they
must be at least 24" from the Antenna Wire.
If the red Learn Indicator Light blinks
approximately 4 times per second,
programming has stopped. If programming
has stopped, repeat the above steps.
Each Button on a 2 or 3 Button Remote Control
is for a different Opener. You cannot use more
than one Button per Remote, per Opener.
A maximum of seven Remote Controls or
Wireless Keypads can be stored into the
Receiver at one time. If a Remote Control
becomes lost, or if you want to delete a Remote
Control or Wireless Keypad, see “To Erase All
Receiver Memory.”
To program one Button of a Remote Control (Figure 12):
• Locate Learn Button and Learn Indicator Light near
Terminal Strip on Power Head (Figure 13).
• Press and release Learn Button. Red Learn Indicator
Light will blink 2 times per second.
• Press Remote Control Button once within 30
seconds. Red Learn Indicator Light will stay lit.
• Press Remote Control Button again. Red Learn
Indicator Light will go out, indicating that
memory is stored.
Program each additional Remote using step A above
(up to seven).
WARNING
A moving garage door may cause serious injury or death.
• Keep people clear of opening while door is moving.
• Do not allow children to play with the Remote Controls.
If the Safety Reverse does not work properly:
• Close the door and disconnect the Opener using the
Emergency Release Cord.
• Do not use the door Opener, Remote Controls, or
Wireless Keypad.
• Refer to the door and door Opener Owner’s Manuals
before attempting any repairs.
Remote Control Operation
Press Button on Remote Control. Garage door will move.
Press Button again. Garage door will stop:
• The door automatically stops at the end of the open or
close cycle.
Press Button again. Garage door will reverse.
Press and hold Learn Button on Power Head for 10
seconds or until Learn Indicator Light goes out.
Memory is erased:
• Program Transmitter/Receiver again as needed.
To Replace Remote Control Battery
FOR NON-FLASHLIGHT MODELS
• Pop off the back of the transmitter.
– Use coin, pen, screwdriver or any similar device.
– Replace old Battery with new coin type battery.
•
Replace back of remote.
FOR FLASHLIGHT MODELS
• Slide open battery cover.
– Replace old Battery with new AAA battery.
•
Replace battery cover.
315 Mhz
Frequency
Switch
390 Mhz
390 Mhz
1 Button Compact Remote 3 Button Compact Remote
w/Docking Station
w/Docking Station
Figure 12 Genie Remote Controls
1 2 3 4
Figure 13 Learn Code Button and Indicator Light
To Erase All Remotes from Power Head Memory
315 Mhz
Frequency
Switch
Some Remote Controls are equipped with a flashlight. The
logo is the button which operates the light. There is a
backlight under the button. When it does not light, it
indicates the battery needs replaced.
Frequency
Switch
Flashlight Button
1 Button Remote
w/Flashlight
3 Button Remote
w/Flashlight
3 Button Large
Remote
w/Flashlight
Figure 14 Genie Remote Controls
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
11
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 12
ABOUT DUAL FREQUENCY
REMOTE TRANSMITTERS
Transmitter Compliance Statement
Your garage door opener (GDO) features a unique
dual frequency remote control system for reliable
service in today’s crowded airwaves. Overcrowded
airwaves may intermittently interfere with GDO’s
remote control system. The dual frequency feature
greatly reduces the possibility of unwanted
interference.
The receiver in the GDO’s powerhead can receive
signals at 315 AND 390 MHz. The remote is factory
set at 315 MHz. See Figure 12 on page 11 for
frequency selector switch.
Switch your remote control frequency when:
• Remote does not have adequate range.
• Remote works inconsistently with fresh battery
installed - LED feedback lights up when pressing
button.
• Programming your car’s HomeLink® system.
To program a HomeLink® device:
(This GDO is HomeLink® compatible.)
• Use a small flat screwdriver to switch the
frequency selector to 390 MHz.
• Follow the HomeLink® instructions in your car
owner’s manual.
• Reset the remote control frequency to 315 MHz for
everyday use.
INSTALL LIGHT BULBS AND LENS
A Install two 60 Watt light bulbs (not included) into Light Sockets
(Figure 13):
• Rough service, 130 Volt bulbs are recommended.
B Hold the lens, with the bottom hinges pointing up, against the power
head metal front cover (Figure 14).
• Insert (2) #8-32 x 3/8”Phillips Hex Head Screws through the Bottom
hinges and into holes provided in metal front cover of Power Head
(Figure 14). Tighten screws.
• Flip Lens up and fasten with (2) #8-32 x 3/8”Phillips Pan Head Screws
where indicated.
Figure 13 Install Lightbulbs
12
Figure 14 Attach Lens
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 13
IMPORTANT
SAFETY
INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF
SEVERE INJURY OR DEATH
READ AND FOLLOW ALL INSTRUCTIONS.
Never let children operate or play with the Door
Controls. Keep the Remote Control away from
children.
Always keep the moving door in sight and away
from people and objects until the door is
completely closed. NO ONE SHOULD CROSS THE
PATH OF THE MOVING DOOR.
NEVER GO UNDER A STOPPED, PARTIALLY
OPEN DOOR.
Test Opener monthly. The door MUST reverse on
contact with a 1-1/2" high object (or a 2" x 4"
board laid flat) at the center of the doorway on the
floor. After adjusting either the Force or the Limit
of travel, retest the Door Opener. Failure to adjust
the Opener properly may cause severe injury
or death.
When possible use the Emergency Release only
when the door is closed. Use caution when using
this Release with the door open. Weak or broken
springs are capable of increasing the rate of door
closure and increasing the risk of severe injury
or death.
KEEP GARAGE DOORS PROPERLY BALANCED. See
garage door Owner's Manual. An improperly
balanced door increases the risk of severe injury
or death. Have a Genie Factory Authorized Dealer
make repairs to cables, spring assemblies, and
other hardware.
SAVE THESE INSTRUCTIONS.
MAINTENANCE
A Monthly:
• Door springs and door hardware:
– Oil door roller, bearings, and hinges using silicone
lubricant or light oil.
WARNING
Do not operate door automatically or manually if springs
are broken. Contact a Genie Factory Authorized Dealer for
service or call Customer Service at 1-800-35-GENIE.
• Balance Door.
– Close door.
– Release Carriage Assembly from Rail Assembly by pulling
the Emergency Release Knob towards the door.
– Raise door manually 3'- 4' and verify that door stays at
that position. See Check Step 2 on page 5.
NOTE
When the door is 3' - 4' above the ground, the door
should stay open. Slight movement is acceptable. If
the door moves too much, contact a Genie Factory
Authorized Dealer for service or call Customer Service at
1-800-35-GENIE.
•
– Reattach Carriage Assembly to Rail Assembly:
a. Pull the Emergency Release Knob toward Power Head.
b. Close door.
Contact Reverse Test.
– Perform Adjustment 2 on page 10.
WARNING
If the door fails to reverse on contact with the board,
adjust the Close Force Control as specified in Set Limit
Switches and Force Controls on page 10. If the Opener
still fails, contact a Genie Factory Authorized Dealer for
service or call Customer Service at 1-800-35-GENIE.
B Yearly:
• Wipe off old excess lubricant from Drive Screw.
• Lubricate Drive Screw with Genie Lubricant (GLU-3)
NOTE
Use ONLY Genie Lubricant (GLU-3). Other lubricants
may damage the Opener.
GLU-3
Lubricant
WARNING
Use the Wall Console included with Opener. Any other
wall console can cause the Opener to operate
unexpectedly and the light to stop working.
age
e Gar icant
w Driv Lubr
Scre OpenerU-3
Door rt No. GL
Pa
FCC AND IC CERTIFIED
All devices comply with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
C As needed
• Replace lightbulbs.
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
13
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 14
TROUBLESHOOTING
Safe-T-Beam® System Self-Diagnostic Troubleshooting
Source (Red LED)
ON
Sensor (Green LED)
ON
OFF
OFF
OFF
ON
2 BLINKS, Pause
(Repeat)
ON
2 BLINKS, Pause
(Repeat)
3 BLINKS, Pause
(Repeat)
4 BLINKS, Pause
(Repeat)
14
OFF
ON
ON
Possible Problem
Normal operation
• Power Head not powered
• Wiring from Power Head bad
Solution
None required
• Check breakers, fuses, plugs
• Check wiring for obvious shorts
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Wiring to Source missing or bad
Power has been interrupted
Beam not aligned
Beam obstructed
Sensor defective
Wire to Sensor missing or bad
Sensor defective
Sensor receiving interference
• Source not sending pulses
• Source defective
Check wiring
Remove power and reapply
Check Source, Sensor alignment
Check for obstruction
Contact Customer Service
Check wiring
Contact Customer Service
Determine source of interference
Check for interference from sunlight or a source unit on an
adjacent door
• Contact Customer Service
• Contact Customer Service
• Contact Customer Service
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 15
General Troubleshooting
Problem
Opener does not run
from Wall Control
Door Opener starts
for no apparent reason
Door starts down, then
stops before it is
completely closed
Door starts down, then
stops and goes back up
Door will only run closed
Door will only run open
Lights will not turn off
Door starts up, but stops
before it is
completely open
Operator runs, but door
does not move
Wall Console Vacation
Lock function does
not work
Noisy Operation
What To Do
1. Check Lock switch on Wall Control (see Wall Console section on Installation Poster).
2. Check Power Source:
• For Grounded Plug Connection.
– Plug a lamp into the electrical outlet used for the door opener.
a. If lamp lights, power source is good.
b. If lamp does not light, check fuse or circuit breaker.
• For Permanent Wiring Connection.
– Check fuse or circuit breaker.
3. Check connections (see Wall Console section on Installation Poster):
• At Power Head Terminals and Wall Control.
1. Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires)
Replace any shorting Staples and shorted Wires.
2. Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory
and reprogram for remaining remote controls. (See Erase All Receiver Memory on page 11).
3. Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls.
1. Check Close Limit Switch setting (page 9 and Installation Poster). Adjust as needed.
2. Check Force Setting (page 9). Adjust as needed.
3. Check for shorted wires.
1. If a new installation, check Door Arm position.
2. Check operation of Contact Reverse function.
3. Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.
4. Check Safe-T-Beam® System diagnostic code.
5. Check Close Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.
6. Check garage door for binding.
1. Check Open Limit Switch for a short circuit and for proper wiring.
2. Check Open Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.
3. Check condition of garage door and door spring(s).
4. WARNING: If you suspect a problem with the garage door hardware or springs,contact a Genie
Factory Authorized Dealer for service,or contact Customer Service at 1-800-35-GENIE.
5. Check position of Lock Switch on Console.
1. Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart
(page 14).
2. Check Close Limit Switch for a short circuit and for proper wiring.
3. Check Close Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.
1. Disconnect Wires connecting Wall Console to Power Head (see “Wall Console Installation”-on Installationposter).
Check their condition and either replace or reconnect.
2. Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls
or Wireless Keypad to operate Opener.
3. Check for non-compatible wall control.
1. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly
balanced as detailed in Maintenance Section.
2. WARNING: If you suspect a problem with the garage door hardware or springs,contact a Genie Factory
Authorized Dealer for service,or contact Customer Service at 1-800-35-GENIE.
3. Check Open Limit Switch for a short circuit and for proper wiring.
4. Check Open Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.
1. Ensure Carriage Assembly is engaged to Rail Drive Screw (see Install Carriage Assembly -INSTALLATION POSTER).
2. Check Force adjustment (see Set Limit Switches and Force Controls on page 9). Adjust as needed.
3. Check that all sections of Rail Drive Screw are turning when Motor runs. If not:
• Check condition (not cracked, split, or broken) and placement of Coupler. Replace as needed.
• Check condition (not cracked, split, or broken) and placement of Collar and Clip. Replace them
as needed.
1. Ensure Carriage Assembly is in contact with Close Limit Switch.
2. Check when door is fully closed, that Carriage activates Close Limit Switch. If not, adjust position of Close
Limit Switch (See page 9).
1. Be sure all fasteners are tight.
2. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly
balanced as described in Maintenance Section (page 13).
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
15
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 16
WIRING DIAGRAM
WARNING
Opening Cover May Cause Electric Shock
POWER CORD
WHITE
WHITE
WHITE
GREEN
BLACK
OPEN
WHITE
GREEN
CLOSE
ORANGE
PRIMARY
SEQUENCER
BLACK
THERMAL PROTECTOR
LIGHTS
BLACK
RED / WHITE
11
BLUE
MOTOR
PRIMARY
10
BLUE
12
RED
GREY
PURPLE
GREEN
ORANGE
ORANGE
YELLOW
SECONDARY
TRANSFORMER
YELLOW
(Vcc)
ORANGE
MOTOR CAPACITOR
RED
(Vcc)
ORANGE
(SIGNAL)
SEQUENCER
HOUSING
(TRIP)
RADIO CONNECTOR
10
11
GREEN
12
13
16
17
16
(COMMAND)
GREY
OPEN
BROWN
CLOSE
GREEN
15
(STB SYSTEM)
14
RPM
SENSOR
GREEN
WHITE
WALL CONTROL
STRIPED
STRIPED
STB SYSTEM
WHITE
TERMINAL STRIP
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 17
PARTS IDENTIFICATION
POWER HEAD
[1]
Power Head Assembly
41
48
49
42
39
Power Head Parts List
Item
39
41
42
48
49
Part Name
Power Head Assembly
Cover (by Series Model)
Front Plate Assembly
Light Socket
Motor Parts
Receiver Assembly
Capacitor (By Series/Model)
Opto Wheel
Opto-Luctor Assembly
Sequencer Assembly
Circuit Board Bracket
Transformer
Terminal Strip
No. 8-32 x 1/2" Hex Head Screw
w/Lockwasher
No. 8-32 x 3/8" Slot Hex Head
Screw w/Lockwasher
Capacitor Isolator
1/4-20 Shoulder Bolt
1/4" Flange Nut
Coupler
No. 8-32 x 3/8" Phillips
Hex Head Screw
No. 8-32 x 3/8" Phillips
Pan Head Screw
Mounting Straps
Light Lens
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Number
Included
17
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 18
PARTS IDENTIFICATION
RAIL
[3]
16
15A
Rail Assembly
44
11
12
3A
39
3B
22
15B
10
24
3C
20
25
28
46
23
17
47
24
13
22
18
25
27
26
21
Parts List (cont’)
Item
3A
3B
3C
10
11
12
13
15A
15B
16
17
18
19
20
21
22
23
24
25
26
27
28
18
Part Name
Power Head Assembly (see page 5)
Rail Assembly (3-piece)
First Rail Section
Middle Rail Section
End Rail Section
1/4”-20 Hex Head Shoulder Bolt
1/4”-20 Hex Flange Nut
Carriage Stop
Rail Clamps
5/16” Hex Head Shoulder Bolt
5/16” Hex Flange Nut
Carriage Assembly
Collar
Retaining Clip
Rail Strap
Open Limit Switch Assembly (grey)
Close Limit Switch Assembly (brown)
#8-32 x 3/8” Hex Head Screw
Emergency Release Cord
Emergency Release Knob
Emergency Release Tag (not shown)
Header Bracket
Door Bracket
1/4” x 2” Lag Screw
Straight Door Arm
Clevis Pin
Cotter Pin
Curved Door Arm
3/8” x 7/8” Hex Head Bolt
3/8” Hex Flange Nut
Number
Included
13
Parts List (cont’)
Item
29
30
31
33
34
35
36
37
38
39
40
41
42
43
44
46
47
48
49
50
Part Name
Wire (not shown)
Insulated Staples (not shown)
Wall Button (not shown)
Wall Console (not shown)
#6 x 1-1/4” Pan Head Screw
Entrapment WARNING Label (not shown)
Safe-T-Beam (STB)Sensor (green LED)
(not shown
Safe-T-Beam Source (red LED)
(not shown)
Safe-T-Beam Bracket (not shown)
Coupler
#10 x 1-1/4” Phillips Hex Head Screw
#8 x 3/8” Hex Head Screw
#8 x 3/8” Pan Head Screw
Safety and Maintenance Guide
(not shown)
Wire Clip
5/16” x 3/4” Hex Head Bolt
1/4”-20 x 3/4” Self-tapping Screw
Mounting Straps
Light Lens (see page 5)
Remote Control (not shown)
Number
Included
~ 95 ft
~ 30
varies
varies
varies
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
2060-3060 eng.qxd
11/9/05
11:02 AM
Page 19
Garage Door Opener Accessories Order Form
Formulario de pedido de accesorios para abridores de puertas de garaje
Formulaire de commande des accessoires pour ouvre-porte de garage
®
How many?
¿Quántos?
Comment
beaucoup?
For additional accessories not shown. visit our website at www.geniecompany.com
Para accesorios adicionalesno mostrada, visite nuestro sitio web en www.geniecompany.com
pour les accessoires supplémentaires pas montré, visiter notré site web à www.geniecompany.com
(GI CTD-1) 1-Button Compact Remote - Allows remote operation of garage door.
Comprima el Mando de Distancia - Proporciónar operación remoto de la puerta del garaje.
Télécommande compacte - Permettre opération éloign´´de porte de garage.
P/N 35674R
$36.50
(GI F TD-1) 1-Button Flashlight Transmitter - Remote Controller with a Flashlight.
1 abrocha transmisor de linterna - Director remoto con una linterna.
1-boutenner l’émetteur de lampe de poche - Le contrôleur éloigné avec de lampe de poche.
P/N 35657R
$45.00
$50.00
(GWC-2W) Deluxe Wall Console - Operates Garage Door. Independent light control. Security vacation lock.
Consola de lujo de pared - Acciona la puerta del garaje. Control de luz independiente. Cerradura de
seguridad para vacaciones.
La Console dse luxe de Mur - Actionne la porte de garage. Commande d’éclairage indépendante.
Interrupteur de verrouillage de sécurité.
P/N 35661R
$35.00
ABC
DEF
GHI
JKL
MNO
PQRS
TUV
WXYZ
9V
Screw Drive Garage
Door Opener Lubricant
Part No. GLU-3
(GW-2) Universal Wall Button - Provides additional convenient inside operation of door.
$3.75
(GPS-5) Perfect Stop - Ensures perfect parking.
®
Stop Perfecto® - Asegura el estacionamiento perfecto.
Butoir Perfect Stop® - Permet de stationner à la perfection dans le garage.
P/N 35677R
$4.00
(GABX8) QuietLift Extension Kit - An Extension that increases the travel of an Opener to accommodate an
eight foot door.
Juego de extensión de cadena deslizable - Una extensión para aumentar la longitud de la baranda de Chain
Glide, para acomodar una puerta de 8 pies (2,43 m).
Nécessaire de prolongement du coulisseau - Rallonge de prolongeant la course de l’ouvre-porte Chain Glide
pour une porte de 2,4 m (8 pi) de hauteur.
P/N 35663R
$32.00
$32.00
$32.00
$2.73
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
SHIPPING & HANDLING
STATE SALES TAX
GRAND TOTAL
5.00
No se aceptan pedidos de pago contra entrega (COD).
Sírvase incluir su cheque o giro postal, la cuenta
pagadera hecha aThe Genie Company. No envíe dinero
en efectivo. Concédanos 3 a 4 semanas para la entrega. 1-800-354-3643. Sírvase tener listos los números
del modelo y de la tarjeta de crédito. Enviar hacer un
pedido de mercancia a: Genie Company, 22790 Lake
Park Blvd, Alliance, Ohio 44601.Aceptamos pedidos
telefónicos de Visa o Mastercard.
Sírvase agregar el impuesto de ventas local si usted reside en uno de
los siguientes estados:
California, Connecticut, Florida, Georgia, Illinois, Indiana,
Maryland, Massachusetts, Michigan, New Jersey, New York,
Ohio, Tennessee, Virginia, Wisconsin
TOTAL DEL PEDIDO
FLETE Y MANEJO
IMPUESTO DE VENTAS ESTATAL
GRAN TOTAL
5.00
Pas d’expédition contre remboursement. Veuillez inclure un
chèque ou un mandat bancaire, le payable fait à The Genie
Company. N’envoyez pas d’argent comptant. Accordez de 3 à 4
semaines pour la livraison. 1-800-354-3643. Ayez sous la main
le numéro de la pièce et celui de la carte de crédit. Mettre à la
poste le arrngement à: Genie Company, 22790 Lake Park Blvd,
Alliance, Ohio 44601. Nous acceptons les commandes par téléphone avec paiement par carte de crédit Visa ou Mastercard.
California, Connecticut, Florida, Georgia, Illinois, Indiana,
Maryland, Massachusetts, Michigan, New Jersey, New York,
Ohio, Tennessee, Virginia, Wisconsin
COMMANDE TOTALE
MANUTENTION ET EXPÉDITION
TAXE DE VENTE
TOTAL GLOBAL
5.00
SHIP ORDER TO:
ENVIAR MERCANCIA CON:
EXPÉDIER MARCHANDISE POUR:
NAME / NOMBRE / NOM
ADDRESS / DIRECCIÓN / ADRESSE
$20.00
STB Adapter Brackets (2) - Used in conjunction with standard STB Brackets.They provide
additional clearance and mounting options.
El adaptador pone entre paréntesis (2) - Usado en unión con paréntesis uniformes de
montar de STB, ellos proporcionan el espacio libre adicional junto con mortar las opciones.
Crochets d’adaptateur (2) - Utilisé conjointement avec STB standard monter les crochets,
ils fournissent le dégagement supplémentaire avec monter d’options.
P/N 34439R.S
Veuillez indiquer les taxes de vente locales si vous résidez dans l’un des
états répertoriés ci-dessous.
(GSX-8) DirectLift Extension Kit - An Extension to increase travel of an Operator to accommodate
eight foot door.
Juego de extensión deslizante de Screw Drive - Una extensión para aumentar la carrera de un abridor
deslizable, para acomodar una puerta de 8 pies (2,43 m.).
Nécessaire de rallonge du Screw Drive - Rallonge de prolongeant la
coursede l’ouvre-porte pour une porte de 2,4 m (8 pi) de hauteur.(GIRU-1T)
P/N 35678R
(60 WATT) Enhanced/Rough Service Light Bulb - Ensures proper equipment compatability.
Bombilla de 60 Vatios - Asegura componente correcto de sistema.
Éclairage de 60 WATT - Garantir componant exact par systéme.
P/N 26210A.S
(GER-2) Emergency Release Kit - Provides access to garage from outside in the event of
an electrical power failure.
Juego de pica-porte de pestillo - Permitir entrtada desde por fuera de garaje porque corte
de eléctrico.
Nécessaires de Déclenchement de secours - Le nécessaire de déclenchement
de secours est conçupour vous permettre d’accéder à votre garage depuis
P/N 35675R
l’extérieur en cas de panne de courant et lorsqu’il.
TOTAL ORDER
Instructions Commandant
(LCGX-8) ChainLift Extension Kit - An Extension that increases the travel of an Opener to accommodate an
eight foot door.
Juego de extensión de cadena deslizable - Una extensión para aumentar la longitud de la baranda de Chain
Glide, para acomodar una puerta de 8 pies (2,43 m).
Nécessaire de prolongement du coulisseau - Rallonge de prolongeant la course de l’ouvre-porte Chain Glide
pour une porte de 2,4 m (8 pi) de hauteur.
P/N 35679R
California, Connecticut, Florida, Georgia, Illinois, Indiana,
Maryland, Massachusetts, Michigan, New Jersey, New York,
Ohio, Tennessee, Virginia, Wisconsin
Las Instrucciones que Ordenan
(GWKPD) Dual Frequency Wireless Keypad - Operates Intellicode® Garage Door Openers without Remote Control
or key.
Sistema de entrada por teclado numérico inalámbrico - Acciona los abridores de puertas de garaje Intellicode® sin
control remoto o llave.
Système d’ouvre-porte de garage à clavier sans fil - Actionne les ouvre-porte de garage avec Intellicode® sans
télécommande ni clé.
P/N 35691R $50.00
(GLU-3) 3/4 oz. Screw Drive Lubricant - Ensures proper equipment wear protection.
3/4 once Lubricante de tornillo accionar - Asegura componente correcto protección por deterioro.
La onza 3/4 Lubricant de la vis - Garantir componant exact par systéme défense vers user. P/N 35218AS
$5.00
Botón de pared universal - Proporciona operación conveniente de la puerta desde el interior.
Bouton mural universel - Actionne l’ouvre-porte de l’intérieur du garage.
P/N 35693R
No C.O.D. shipments. Please include check or money
order, made payable to The Genie Company. Do not
send cash. Allow 3-4 weeks for delivery.
1-800-354-3643. Please have part number and credit
card ready. Mail Order Form to: Genie Company,
22790 Lake Park Blvd, Alliance, Ohio 44601. We
accept Visa or Mastercard on phone orders only.
Please add local sales tax if you reside in one of the states listed.
(GI CTD-3) 3-Button Compact Remote - Allows remote operation of 3 garage doors.
De 3 botones Comprima el Mando de Distancia - Proporciónar operación remoto de tres las puertas del garaje.
3-boutenner la Télécommande compacte - Permettre opération éloign´ trois portes
P/N 35694S
de garage.
Ordering Instructions
CITY / CIUDAD / VILLE
STATE / ESTADO / ÉTAT
ZIP / CÓDIGO POSTAL / CODE POSTAL
$4.37
(Prices subject to change without notice)
(Valoran el cambio con sujeción a sin nota)
(Les prix assujettissent pour changer sans la notification)
19
2060-3060 eng.qxd
20
11/9/05
11:02 AM
Page 20
For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 2005:11:09 11:02:35Z
Creator Tool                    : QuarkXPress(tm) 6.5
Modify Date                     : 2005:11:11 07:21:37-05:00
Metadata Date                   : 2005:11:11 07:21:37-05:00
Producer                        : QuarkXPress(tm) 6.5
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (PANTONE 2665 U).%%+ (C100K10).%%RGBCustomColor: .303 .33 .703 (PANTONE 2665 U).%%+ .007 .564 .698 (C100K10).%%EndComments
Format                          : application/pdf
Title                           : 2060-3060 OWNERS MAN-1.qxd
Document ID                     : uuid:d54583be-51e3-11da-b41f-0050e445647e
Instance ID                     : uuid:b51d39df-52ad-11da-b41f-0050e445647e
Has XFA                         : No
Page Count                      : 20
Creator                         : QuarkXPress(tm) 6.5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: B8Q315390R2

Navigation menu