Product Evaluation
DR599 | 0716

Engineering Services Program

The following product has been evaluated for compliance with the wind loads specified in the International
Residential Code (IRC) and the International Building Code (IBC).
This product evaluation is not an endorsement of this product or a recommendation that this product be used.
The Texas Department of Insurance has not authorized the use of any information contained in the product
evaluation for advertising, or other commercial or promotional purpose.
This product evaluation is intended for use by those individuals who are following the design wind load criteria in
Chapter 3 of the IRC and Section 1609 of the IBC. The design loads determined for the building or structure shall
not exceed the design load rating specified for the products shown in the limitations section of this product
evaluation. This product evaluation does not relieve a Texas licensed engineer of his responsibilities as outlined
in the Texas Insurance Code, the Texas Administrative Code, and the Texas Engineering Practice Act.
For more information, contact TDI Engineering Services Program at (800) 248-6032.

Evaluation ID:

DR-599

Product Name:

8"- 0" Glazed Fiberglass Impact Resistant Doors, Inswing & Outswing, Singles & Doubles
with and without Impact Resistant Sidelites

Manufacturer:

Therma-Tru Corporation
118 Industrial Drive
Edgerton, OH 43517
(419) 298-1740

General Description:
System
1
2

3
4
5

Effective Date:
Re-evaluation Date:

Description

3'-0" x 8'-0" Glazed Fiberglass
Single Door Inswing/Outswing (X)
3'-0" x 8'-0" Glazed Fiberglass
Single Door w/ Boxed Sidelite & Combination
Reinforced Mullion Inswing/Outswing (XO), (OX)
3'-0" x 8'-0" Glazed Fiberglass
Single Door w/ Boxed Sidelites & Combination
Reinforced Mullion Inswing/Outswing (OXO)
6'-0" x 8'-0" Glazed Fiberglass Double Door,
Inswing/Outswing (XX)
6'-0" x 8'-0" Glazed Fiberglass Double Door, w/
Boxed Sidelites & Combination Mullion
Inswing/Outswing (OXXO)

Label
Rating
Inswing +50/-50 psf
Outswing +50/-50 psf
Inswing +47/-47 psf
Outswing +47/-47 psf
Inswing +47/-47 psf
Outswing +47/-47 psf
Inswing +50/-50 psf
Outswing +50/-50 psf
Inswing +50/-50 psf
Outswing +50/-50 psf

July 1, 2016
July 2020

Drawing
Number
TX-4195
Rev 1
TX-4196
Rev 1
TX-4197
Rev 1
TX-4198
Rev 1
TX-4199
Rev 1

Texas Department of Insurance | 333 Guadalupe Street | Austin, Texas 78714 | (800) 248-6032 | www.tdi.texas.gov | @TexasTDI

DR599 | 0716

Dimensions:
System
1
2
3

Overall Size

Inswing: 37-3/4" x 98"
Outswing: 37-3/4" x 96-3/4"
Inswing: 76-3/4" x 98"
Outswing: 76-3/4" x 96-3/4"
Inswing: 115-3/4" x 98”
Outswing: 115-3/4" x 96-3/4"

4

Inswing: 74-1/2" x 98”
Outswing: 74-1/2" x 96-3/4"

5

Inswing: 151" x 98”
Outswing: 151" x 96-3/4"

Sidelite
Panel Size

36" x 95-1/4"

NA

36" x 95-1/4"

36" x 95-1/4"

36" x 95-1/4"

36" x 95-1/4"

36" x 95-1/4"
36-3/4" x 95-1/4"
(with astragal)
36" x 95-1/4"
36-3/4" x 95-1/4"
(with astragal)

Hardware Description and Installation:
System
Component

1-5

Door
Panel Size

NA

Door: 21" x 78-3/4"
Sidelite: NA

36" x 95-1/4"

Door: 21" x 78-3/4"
Sidelite: 21" x 78-3/4"

Quantity

Attachment Method

4" Butt Hinges

4

Lock and deadbolt strike plate

1 per lockset and
deadbolt

Kwikset 200 Series Lock
and
Kwikset 780 Series Deadbolt

1 each

For proper installation of
Hardware and components refer
to Therma-Tru Corporation
Drawings: TX-4195 Rev 1, TX-4196
Rev 1, TX-4197 Rev 1, TX-4198
Rev 1, and TX-4199 Rev 1, dated
7/17/2012, signed and sealed by
Lyndon F. Schmidt, P.E. on
7/22/2015.

Product Identification (Manufacturer Label on Door):
System
Certification Agency
Manufacturer’s Name or Code Name
1

Max Daylight Opening
size
Door: 21" x 78-3/4"
Sidelite: NA
Door: 21" x 78-3/4"
Sidelite: 21" x 78-3/4"
Door: 21" x 78-3/4"
Sidelite: 21" x 78-3/4"

Product Name
Test Standards

Texas Department of Insurance | www.tdi.texas.gov

Self-labeled by manufacturer
Therma-Tru Corporation, Edgerton, OH
Glazed Fiberglass Single Door
(Smooth Star, Fiber Classic, Classic Craft, Classic
Craft Rustic)
ASTM E330-02; ASTM E 1886-02;
ASTM E 1996-02

Page 2 of 4

DR599 | 0716

Product Identification (Manufacturer Label on Door) - Continued:
System
Certification Agency
Self-labeled by manufacturer
Manufacturer’s Name or Code Name
Therma-Tru Corporation, Edgerton, OH
Glazed Fiberglass Single Door
w/ Boxed Sidelite & Combination Reinforced
2
Product Name
Mullion
(Smooth Star, Fiber Classic, Classic Craft, Classic
Craft Rustic)
ASTM E330-02; ASTM E 1886-02;
Test Standards
ASTM E 1996-02
Certification Agency
Self-labeled by manufacturer
Manufacturer’s Name or Code Name
Therma-Tru Corporation, Edgerton, OH
Glazed Fiberglass Single Door
w/ Boxed Sidelites & Combination Reinforced
3
Product Name
Mullion
(Smooth Star, Fiber Classic, Classic Craft, Classic
Craft Rustic)
ASTM E330-02; ASTM E 1886-02;
Test Standards
ASTM E 1996-02
Certification Agency
Self-labeled by manufacturer
Manufacturer’s Name or Code Name
Therma-Tru Corporation, Edgerton, OH
Glazed Fiberglass Double Door
4
Product Name
(Smooth Star, Fiber Classic, Classic Craft, Classic
Craft Rustic)
ASTM E330-02; ASTM E 1886-02;
Test Standards
ASTM E 1996-02
Certification Agency
Self-labeled by manufacturer
Manufacturer’s Name or Code Name
Therma-Tru Corporation, Edgerton, OH
Glazed Fiberglass Double Door, w/ Boxed
Sidelites & Combination Mullion
5
Product Name
(Smooth Star, Fiber Classic, Classic Craft, Classic
Craft Rustic)
ASTM E330-02; ASTM E 1886-02;
Test Standards
ASTM E 1996-02
Impact Resistance:
System
Impact Resistant
1-5
Glazed
Doors &
Sidelites

Yes

Texas Department of Insurance | www.tdi.texas.gov

Requirement
These products satisfy the Texas Department of Insurance’s
criteria for protection from windborne debris in the Inland I and
Seaward zone. The assemblies may be installed at any height on
the structure as long as the design pressure rating for the
assemblies is not exceeded.

Page 3 of 4

DR599 | 0716

Acceptance of Smaller Assemblies: Door assemblies with dimensions equal to, or smaller than those
specified are acceptable with the limitations specified in this report.
Sidelites: Sidelites must only be used with doors. Sidelites must not be installed individually.
Installation:
System

1-5

Type of Installation
Wall Framing
Fasteners
Fastener Embedment
Fastener
Location/Spacing

For proper installation of doors and sidelites refer to ThermaTru Corporation drawings: TX-4195 Rev 1, TX-4196 Rev 1, TX4197 Rev 1, TX-4198 Rev 1, and TX-4199 Rev 1, dated
7/17/2012, signed and sealed by Lyndon F. Schmidt, P.E. on
7/22/2015.

Note: Keep the manufacturer’s installation instructions at the job site during installation. Use corrosion
resistant fasteners as specified in the IRC, the IBC, and the Texas Revisions.

Texas Department of Insurance | www.tdi.texas.gov

Page 4 of 4

