184

MODELS SHOWN: UCVM36FS 36-INCH DOWNDRAFT WITH CIT365KM INDUCTION COOKTOP

VENTILATION — DOWNDRAFT

VENTILATION
DOWNDRAFT
If you prefer a concealed look, choose a Thermador Downdraft Ventilation Unit, which offers
space efficiency when a hood is not preferred. The full-face filter combines a filter with a splatter
shield in one easy-to-remove, dishwasher-safe element. Thermador invented the first retractable
downdraft, and was also the first to introduce a recirculation option for downdrafts — making
ventilation possible in any kitchen.

1.800.735.4328 | THERMADOR.COM

185

DOWNDRAFT
FEATURES & BENEFITS
PLANNING INFORMATION
MODEL OPTIONS
Thermador Downdraft Hoods are available in 30 and 36-inch
widths to fit your kitchen plans and are meticulously crafted for
both function and design. Be sure to reference the correct model
information in this design guide.
ELECTRICAL SPECIFICATIONS
Be sure your Thermador Downdraft Hood is properly installed
and grounded by a qualified technician. Installation, electrical
connections and grounding must comply with all applicable
local codes.

MODEL

REQUIRED CIRCUIT
BREAKER
120V AC, 60 Hz

UCVM30FS, UCVM36FS

15 Amp

INSTALLATION CONSIDERATIONS
Full 13-INCH Rise
With an over 13-inch intake, the UCVM rises well above even the
tallest pans. This protects against splatters when cooking and provides
better performance in capturing steam and smoke — even from the
front burners.
Downdraft Recirculation Option
Downdraft recirculation is now available for island or wall applications.
Combine the performance of the UCVM Downdraft with the odor- and
grease-capturing filters in the Recirculation Module for the perfect
ventilation combination for anywhere in your kitchen.
Full-Face Filters
Full-face filters combine a filter with a splatter shield in one easyto-remove, dishwasher-safe element. These filters maximize grease
capture without affecting airflow.

The information in this design guide provides key features,
product dimensions, cutouts and installation specifications.
Before installing a Thermador Downdraft Hood, be sure to verify
the cutout dimensions and electrical connections. Also, always
consult with the installation manual packed with the product for
complete details before installing.
Thermador Downdraft Hoods may be installed in a wall or island
behind a Thermador non-professional gas, electric or induction
cooktop to create a convenient cooking center. Refer to the
appropriate section for additional specifications.
Hood Width
Downdraft ventilation units should be the same width as the
cooking surfaces they are ventilating.
Choosing the Correct Blower
A variety of interior and exterior blower options (Remote, Inline
or Integrated) are available for Thermador’s Downdraft Hoods.
If the unit you have selected does not have a blower, one can
be purchased separately. Blower selection will vary based on
the volume of air that needs to be moved and the length and
location of the duct run. For long duct runs with multiple turns
and bends, consider using a more powerful blower. For the most
efficient air flow exhaust, use a straight run or as few elbows
as possible.
Remote Blowers (VTR Series)
Depending on your preference and ducting situation, these
blowers can be mounted on the roof or exterior wall of your
home. An exterior installation may be more appealing to reduce
noise in the kitchen.
Inline Blowers (VTI series)
To minimize noise in the kitchen, these blowers are mounted
along the duct line anywhere between the kitchen and the
exterior wall. If you have easy access to your duct line (in an attic,
for example), this may be an appealing option.
Integrated Blowers (VTN series)
These blowers are purchased separately and integrated into the
hood or onto the downdraft unit at the time of installation. This
option allows you to select your ideal hood with the exact power
you require.

186

Choosing the Right CFM
The power of the cooktop, measured in BTU, is perhaps
the most important factor in determining CFM needs for
a hood. Professional Gas Rangetops generally should
have 1 CFM for every 100 BTU.

BLOWER OPTIONS
REMOTE

Requires CV2T6 or CV2T10 Transition

VTR630D – 600 CFM

Use RFPLT600 in roof-mount applications

You should also consider the cooking space and cooking
style of your client.

VTR1030D – 1000 CFM

Use RFPLT1000 in roof-mount applications

• More demanding cooks usually require more exhaust
capacity to handle moisture generated by boiling large
pots of water or the grease and smoke resulting from
grilling or frying. This cooking style could require a hood
or downdraft system with airflow of 600 to 1,300 CFM.

INLINE

• For those who are used to preparing quick meals in a
relatively small kitchen, a hood with 600 CFM may be
adequate ventilation for the cooking space.

VTN600CV2C – 600 CFM

• If the cooking surface is in a peninsula or island, a larger
capacity hood can provide better capture when there
are cross currents and when the hood needs to be
mounted higher. Downdraft ventilation systems are also
a good alternative.

Requires CV2T6 or CV2T10 Transition

VTI610D – 600 CFM
VTI1010D – 1000 CFM

VENTILATION — DOWNDRAFT

DOWNDRAFT
FEATURES & BENEFITS

INTEGRATED

REMOTE (Mounted to roof or external wall)
VTR630D – 600 CFM

VTR1030D – 1000 CFM

• High heat cooking or aromatic foods may require
additional CFM. Increasing capture area by 3" on each
side is also a recommended way to address this issue.
Length and Size of Ductwork
Do not use flexible duct; it creates back pressure/air
turbulence and reduces performance.
Straight runs and gradual turns are best. Use the shortest
route with the fewest turns possible.

INLINE (Mounted between kitchen and external wall)
VTI610D – 600 CFM

VTI1010D – 1000 CFM

Proper performance is dependent upon proper ducting.
Use a qualified and trained installer. Local building codes
may require the use of make-up air systems when using
ducted ventilation systems greater than specified CFM
of air movement. The specified CFM varies from locale
to locale. Consult your HVAC professional for specific
requirements in your area.
If using a 10" duct, Thermador recommends not
exceeding 150 feet of duct. Transitions, elbows and
wall or roof caps are all factors that will add more static
pressure, therefore increasing your equivalent duct run.

INTEGRATED (Mounted on hood)
VTN600CV2C – 600 CFM

WARRANTY
Limited warranty parts and labor (2 year)
See page 308 for additional warranty details.

­REMOTE BLOWER ACCESSORIES
RFPLT600
For use with Remote
Blower VTR630D

1.800.735.4328 | THERMADOR.COM

RFPLT1000
For use with Remote
Blower VTR1030D

187

VENTILATION
DOWNDRAFT (30"/36")
UCVM30FS / UCVM36FS

UCVM30FS / UCVM36FS
Performance
- Suitable for wall or island applications
- Downdraft rises over 13" to capture steam from the tallest pots
- Downdraft recirculation possible with module RECIRC36DF
- Three fan speeds
- Dishwasher-safe full-face filters also act as a splatter shield
- Filter systems are highly efficient at capturing grease
- Powerfully Quiet® ventilation systems
- Blowers sold separately
- Choose from Inline, Remote or Integrated Blowers
- Replacement charcoal filters available (CHFILT3036)

MASTERPIECE
UCVM30FS – 30-Inch
UCVM36FS – 36-Inch

Design
- Brushed stainless steel finish
- Easy-to-operate control buttons

­TRANSITIONS

SPECIFICATIONS
Available Hood Widths

30" / 36"

Blower

Sold Separately —
See Blower Options Table

Duct Size at Discharge

6" Round

Ducting Direction

Down, Left or Right

Dishwasher-safe Filters

Full-Face Mesh

Electrical

120V AC, 60Hz

Transition piece required for installation of inline and remote
blowers — downdraft applications only
CV2T6
Transition piece required
for installation of 600 CFM
Inline and Remote Blowers
with 6" duct connections —
downdraft applications only

14 3/8"

15 1/8"

CV2T10
Improves overall
performance when installing
with Thermador’s 1,000 CFM
Inline or Remote Blowers
with 10" duct connections —
downdraft applications only

Ø 6"

6 3/4"

14 3/8"

14 7/16"

Ø 10"

11"

ACCESSORIES

188

Recirculation Kit

Replacement Charcoal Filters

RECIRC36DF
-C
 omes complete with 2 charcoal filters, 2 venting
grids, and ducting to transition to integrated
blower (blower sold separately)
- For toekick heights of 4" or taller
- Wall or island applications
-E
 asily mounts to integrated blower (VTN600CV2C)
under cooktop
- Toekick/socket can be vented in any direction
- Mounts to base of cabinet; recesses into toekick
-T
 o be used only with Thermador Downdraft and
Integrated Blower
- Replacement filters are ordered as a service item
- Filters should be replaced twice a year

Sold separately as a service item
(For use with recirculation module)

UCVM30FS / UCVM36FS

INSTALLATION OPTIONS

CUTOUT DIMENSIONS (TOP VIEW)

The Thermador Downdraft Hood System is
available in 30-inch or 36-inch widths. It is intended
for installation with Thermador non-professional
gas, electric or induction cooktops only.

36 7/8"
30 7/8"

A Recirculation Kit (RECIRC36DF) can be
purchased separately and used in conjunction with
the Integral Blower if ducting to the outside is not
a viable option. Refer to the appropriate section
for additional specifications.
These hoods are designed to be used for side or
downward discharge.

VENTILATION — DOWNDRAFT

VENTILATION
DOWNDRAFT (30"/36")

36 7/8"
(936 mm)

30 7/8"
(784 mm)

36 7/8"
30 7/8"

36 7/8"
30 7/8"

1.800.735.4328 | THERMADOR.COM

189



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2012:07:03 14:44:36-07:00
Creator                         : Adobe InDesign CS5.5 (7.5)
Modify Date                     : 2012:07:03 14:45:27-07:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2012:07:03 14:45:27-07:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5)
Format                          : application/pdf
Document ID                     : uuid:f1f925a6-0a57-493e-8e95-efbe03b97911
Instance ID                     : uuid:3bce2dbb-26dc-4195-a073-d153de2d29f8
Producer                        : Adobe PDF Library 9.9
Page Count                      : 6
EXIF Metadata provided by EXIF.tools

Navigation menu