SAILOR AP5065 Alarm PanelINSTALLATION MANUAL
10715DisclaimerAny responsibility or liability for loss or damage in connection with the use of this product andthe accompanying documentation is disclaimed by Thrane & Thrane. The information in thismanual is provided for information purposes only, is subject to change without notice, maycontain errors or inaccuracies, and represents no commitment whatsoever by Thrane &Thrane. This agreement is governed by the laws of Denmark.Manuals issued by Thrane & Thrane are periodically revised and updated. Anyone relying onthis information should satisfy himself/herself as to the most current version. Providers withaccess to Thrane & Thrane’s Extranet may obtain current copies of manuals at: http://extranet.thrane.com.Thrane & Thrane is not responsible for the content or accuracy of any translations orreproductions, in whole or in part, of this manual from any other source.ContentsIntroduction .............................................................................................................................. 3General Description ............................................................................................................. 3Technical Data ..................................................................................................................... 4Operation................................................................................................................................... 5Distress ................................................................................................................................5General................................................................................................................................. 6Installation................................................................................................................................. 7Connector overview ............................................................................................................. 7Auxiliary interfaces............................................................................................................... 7Interconnecting more Alarm Panels .................................................................................... 8Wiring interconnected Alarm Panels ................................................................................... 9Wiring to VHF 1 or VHF 2 .................................................................................................. 10Wiring to MF/HF ................................................................................................................. 11Wiring to Inmarsat-C 1 or Inmarsat-C 2 (mini-C) .............................................................. 12Wiring to 24V DC Supply ................................................................................................... 13Outline and dimension ....................................................................................................... 14
20715
30736IntroductionGeneral DescriptionThe GMDSS Distress Alarm Panel is used for remote initiation of distress alert transmissionsand visible and audible indication of incoming distress and urgency calls on VHF, MF/HF,and Inmarsat-C. Normally it is installed on the bridge at the conning position.The Alarm Panel contains three main sections, intended for connection to System 5000 VHF,System 5000 MF/HF equipment, and Inmarsat-C SES equipment. All sections work inde-pendently and all control signals are galvanically isolated by opto-couplers.For Inmarsat-C and VHF, the Alarm Panel has duplicated connections allowing two units ofeach system to be supported simultaneously. Each section includes a push button fordistress alert initiation, and a distress annunciator for indication of distress alert transmissionin progress or distress or urgency calls received. Additionally there is an annunciator forindication of equipment type. This is switched on when the appropriate transceiver has beensensed by the Alarm Panel.If a distress alarm is initiated on a system with duplicated units, only one of the units willsend the alarm. The selected unit is indicated on the display.To protect against inadvertent activation the distress buttons are protected by spring loadedtransparent covers. A button must be kept pressed for 5 seconds before the distress alert isinitiated, during which time the audible alarm is beeping and the distress button is flashing.The Alarm Panel is supplied from 24 V DC supply voltage (21 V to 32 V). The input isreverse polarity protected.
40715Technical DataGeneralIlluminated red distress button with transparent cover for each section.Indicator Alarm Panel with distress annunciator and status information for each connectedunit.Audible alarm for indication of distress alert transmission in progress, or distress or urgencycalls received.Dimmer push button for controlling light intensity in the indicator Alarm Panel.Mute push button for resetting the audio alarm.Test push button for verification of indicators, audible alarm and push buttons.All distress functions work fully independent of each other.All control signals are galvanically isolated by opto-couplers.The indication line in the display goes off if the connection to the associated transceiver isbroken.  When the connection is re-established it may take up to 20 seconds before it isindicated in the display.Supply Voltage: 24 V DC (21 V to 32 V)Current consumption: max.100 mAOperating temperature range: -20°C to +55°CCompass safe distance: Standard: 0.9 m. Steering: 0.6 m.
50736OperationDistressSending Distress AlertOpen the key cover and press the ‘DISTRESS’ push button for minimum 5 seconds. Thealert button and the selection annunciator for the active unit flashes, and the buzzer soundsperiodically.When the distress alert transmission starts, the distress button and the selection annunciatorchange to a constant light. This indication is also given if a distress alert is initiated from thetransceiver.When a distress acknowledgement has been received the distress annunciator flashes andthe buzzer sounds periodically - except Inmarsat-C equipment where distress buttonchanges to a slow cycle and the buzzer remains silent. Furthermore the dimmer will be set tofull light intensity.When the distress acknowledgement has been read out or a distress/urgency alert has beencancelled at the appropriate transceiver, the call lamp and buzzer on the Alarm Panel areswitched off.Reception of Distress or Urgency CallsReception of Distress or Urgency calls, EGCs, and messages are indicated by a slowlyflashing distress annunciator and a periodic sound from the buzzer. Furthermore the dimmerwill be set to full light intensity.
60715GeneralTest the Alarm PanelPressing and holding the Test button will make all light indicators and alarm buttons flash.Pressing any other button while holding the Test button, will sound the buzzer enablingverification of the buttons and the audible indicator.Note that this only tests the Alarm Panel itself and does not involve the connected trans-ceiver unit. For description of system test procedures, please refer to the User’s Manual ofeach of the system.Mute the alarm soundIf the buzzer is on, pressing the Mute button will mute the buzzer until reactivated by a newevent.Adjust the light intensityPressing and holding the Dimmer button will increase or decrease the light intensity in thedisplay. To change between increasing and decreasing, release the button and press itagain. The light can be decreased to distinction, but it will always turn to full intensity if anydistress indicators turn on, or if the Test button is pressed.40673
70736InstallationConnector overview40708OptionVHF 2VHF 1 MF/HFDC SupplyInm-C 1Inm-C 2The Alarm Panel will connect to 5 transceiver units (2 × VHF, 2 × Inmarsat-C, and 1 × MF/HF) each of which is provided a dedicated connector on the rear side of the Alarm Panel.Auxiliary interfacesThe AP5065 Alarm Panel provides, through the option connector an auxiliary RS-422 linewith a separate Rx and Tx pair, that can be connected to external equipment for monitoringof the Alarm Panel state. Unless specific installation instructions describes otherwise, thisinterface should not be connected.The power connector also provides a Service interface connection that may be used forfuture maintenance of the Alarm Panel. Leave this disconnected for normal use.
80736Interconnecting more Alarm Panels4071524V24VInterconnected panelsCable length < 200 meter24V24V24V24VInmarsat-C 1VHF 1Inmarsat-C 2VHF 2MF/HFAlarm Panel 1 Alarm Panel 2 Alarm Panel 3Up to 3 Alarm Panels can be interconnected and placed in different locations on the vessel.Interconnected Alarm Panels maintain identical light and sound indications, so any operationand behaviour on either Alarm Panel will be reflected on the others (except using theDimming button and the Test button – which only affects the single Alarm Panel beingdimmed or tested).If interconnection is used, the combined set of Alarm Panels still only accepts the same 5transceiver units, but each transceiver may be connected to either of the interconnectedAlarm Panels (e.g., the secondary VHF transceiver can be connected to the VHF 2 connec-tor of any of the Alarm Panel).The interconnection is physically established using a twisted pair cable. The interface iselectrically isolated and it must be supplied with 15V power to one of the Alarm Panels. The15V interface power is taken from a dedicated supply available in the 9-pin power connector.Note that only one of the interconnected Alarm Panels must supply the interface with powerin order to maintain the electrical isolation in the installation.
9Wiring interconnected Alarm Panels40714AAlarm Panel 1 Alarm Panel 2 Alarm Panel 3101112132223242589OptionDC SupplyOption OptionINTER SINTER CINTER HINTER L* 12010111213222324251011121322232425120**Note: The terminator resistor must match the cable used 120is a typical value.DC supplyD-sub 9 Designation1ID-GND2 S-RX SERVICE INTERFACE3 S-TX SERVICE INTERFACE4ID5 GND SERVICE INTERFACE6 DC- SUPPLY INPUT7 DC+ SUPPLY INPUT8 INTER-COUT INTERFACE SUPPLY OUT9 INTER-SOUT INTERFACE SUPPLY OUTOptionD-sub 251 and 14 AUX-TALKER B2 and 15 AUX-TALKER A3 and 16 AUX-TALKER C5 and 18 AUX-LISTENER B6 and 19 AUX-LISTENER A7 and 20 AUX-LISTENER C10 and 22 INTER L11 and 23 INTER H12 and 24 INTER C13 and 25 INTER S4.8.9 and 17 NCNote: The cable shield must be connected only to the Alarm Panel that powers theinterface (Alarm Panel 1 in the wiring diagram). All segments of the interface cablemust have connected shields”0736
10Wiring to VHF 1 or VHF 240712lenaPmralA 3X'FHV' yaw9buS-D noitangiseD FHV SUB-CRAPS yaw51buS-D tnemmoC3+SUB-CRAPS2riapdetsiwT5-SUB-CRAPS32DNG69V21+7²mm5.0x2x2:epytelbaCm001.xaM:htgneL,deneercsNote: The cable shield must be connected to chassis on the VHF equipment and mustbe left unconnected at the Alarm Panel.”0715
11Wiring to MF/HF40711lenaPmralA 4X'FH/FM' yaw9buS-D noitangiseD FH/FM XUA yaw9buS-D tnemmoC3+SUB-CRAPS1riapdetsiwT5-SUB-CRAPS62DNG59V42+7²mm5.0x2x2:epytelbaCm001.xaM:htgneL,deneercsNote: The cable shield must be connected to chassis on the MF/HF equipment andmust be left unconnected at the Alarm Panel.”0736
12Wiring to Inmarsat-C 1 or Inmarsat-C 2 (mini-C)40710Alarm Panel mini-CInm-C Designation CommentD-sub 9 way J3021,2 GND GND3,7 Data + Data +4,5 Data - Data -8,9 VCC IN +9VCable type: min. 2 x 2 x 0.2mm2 screened.Length: Max 250mTwisted pairNote 1: The cable shield must be connected to chassis on the Inmarsat-C equipment andmust be left disconnected at the Alarm Panel.”Note 2: If the cable ends at the Alarm Panel, then connect a strap between pin 6 and 7 inorder to activate an internal termination resistor.Note 3: For further details refer to TT-3000E mini-C GMDSS system Installation manual(Doc. TT98-122414)Note 4: Connection of a classic Inmarsat-C transceiver (TT-3020C) to the Alarm Panelrequires interface TT-3687A installed. For details refer to TT-3687A Alarm Paneladapter Installation & User manual (Doc. TT98-125903)0736
130736Wiring to 24V DC Supply40716AAlarm Panel Alarm PanelDC Supply Designation OptionD-sub 9 way Connector6 DC -7DC +8 INTER-COUT 12 (Note)9 INTER-SOUT 13 (Note)Cable type: 2 x 0.5mm2 screened.Length: Max. 100mWiring: 2 x 0.2mm2.Length: 0.15 - 0.2mNote:Interface supply used only if interconnecting 2 or 3 alarm panels - refer to page 8.
14Outline and dimension40674A10012810014160.531.5Space for cable entrymin. 150Mounting option Drilling plan407228630109.2457.511.6Tilting±45°4 x ø 4.5Dimensions are in mm.Weight:AP5065 0.8 Kg0736
15Alarm panel with mounting bracket40723B140120Panel mounting kit (Option)Part no 405065A-9209.6Space for cable entrymin. 150Drilling plan105105610812864 x ø517.57.54 x ø3.5 uns for M3 ISO 1458120 204 pcs M4x304 pcs M3x303 pcs M3x8Cut outDrilling plan0736