Thrane and Thrane A S TU5160 Sailor System 5000 150W GMDSS MF/HF SSB DSC NBDP User Manual 98 125065 THR B pmd
Thrane & Thrane A/S Sailor System 5000 150W GMDSS MF/HF SSB DSC NBDP 98 125065 THR B pmd
Contents
user manual 1
INSTALLATION MANUAL SAILOR AP5065 Alarm Panel Contents Introduction .............................................................................................................................. 3 General Description ............................................................................................................. 3 Technical Data ..................................................................................................................... 4 Operation ................................................................................................................................... 5 Distress ................................................................................................................................ 5 General ................................................................................................................................. 6 Installation ................................................................................................................................. 7 Connector overview ............................................................................................................. 7 Auxiliary interfaces ............................................................................................................... 7 Interconnecting more Alarm Panels .................................................................................... 8 Wiring interconnected Alarm Panels ................................................................................... 9 Wiring to VHF 1 or VHF 2 .................................................................................................. 10 Wiring to MF/HF ................................................................................................................. 11 Wiring to Inmarsat-C 1 or Inmarsat-C 2 (mini-C) .............................................................. 12 Wiring to 24V DC Supply ................................................................................................... 13 Outline and dimension ....................................................................................................... 14 Disclaimer Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane. The information in this manual is provided for information purposes only, is subject to change without notice, may contain errors or inaccuracies, and represents no commitment whatsoever by Thrane & Thrane. This agreement is governed by the laws of Denmark. Manuals issued by Thrane & Thrane are periodically revised and updated. Anyone relying on this information should satisfy himself/herself as to the most current version. Providers with access to Thrane & Thrane’s Extranet may obtain current copies of manuals at: http:// extranet.thrane.com. Thrane & Thrane is not responsible for the content or accuracy of any translations or reproductions, in whole or in part, of this manual from any other source. 0715 2 0715 Introduction General Description The GMDSS Distress Alarm Panel is used for remote initiation of distress alert transmissions and visible and audible indication of incoming distress and urgency calls on VHF, MF/HF, and Inmarsat-C. Normally it is installed on the bridge at the conning position. The Alarm Panel contains three main sections, intended for connection to System 5000 VHF, System 5000 MF/HF equipment, and Inmarsat-C SES equipment. All sections work independently and all control signals are galvanically isolated by opto-couplers. For Inmarsat-C and VHF, the Alarm Panel has duplicated connections allowing two units of each system to be supported simultaneously. Each section includes a push button for distress alert initiation, and a distress annunciator for indication of distress alert transmission in progress or distress or urgency calls received. Additionally there is an annunciator for indication of equipment type. This is switched on when the appropriate transceiver has been sensed by the Alarm Panel. If a distress alarm is initiated on a system with duplicated units, only one of the units will send the alarm. The selected unit is indicated on the display. To protect against inadvertent activation the distress buttons are protected by spring loaded transparent covers. A button must be kept pressed for 5 seconds before the distress alert is initiated, during which time the audible alarm is beeping and the distress button is flashing. The Alarm Panel is supplied from 24 V DC supply voltage (21 V to 32 V). The input is reverse polarity protected. 0736 Technical Data General Illuminated red distress button with transparent cover for each section. Indicator Alarm Panel with distress annunciator and status information for each connected unit. Audible alarm for indication of distress alert transmission in progress, or distress or urgency calls received. Dimmer push button for controlling light intensity in the indicator Alarm Panel. Mute push button for resetting the audio alarm. Test push button for verification of indicators, audible alarm and push buttons. All distress functions work fully independent of each other. All control signals are galvanically isolated by opto-couplers. The indication line in the display goes off if the connection to the associated transceiver is broken. When the connection is re-established it may take up to 20 seconds before it is indicated in the display. Supply Voltage: 24 V DC (21 V to 32 V) Current consumption: max.100 mA Operating temperature range: -20°C to +55°C Compass safe distance: Standard: 0.9 m. Steering: 0.6 m. 0715 Operation Distress Sending Distress Alert Open the key cover and press the ‘DISTRESS’ push button for minimum 5 seconds. The alert button and the selection annunciator for the active unit flashes, and the buzzer sounds periodically. When the distress alert transmission starts, the distress button and the selection annunciator change to a constant light. This indication is also given if a distress alert is initiated from the transceiver. When a distress acknowledgement has been received the distress annunciator flashes and the buzzer sounds periodically - except Inmarsat-C equipment where distress button changes to a slow cycle and the buzzer remains silent. Furthermore the dimmer will be set to full light intensity. When the distress acknowledgement has been read out or a distress/urgency alert has been cancelled at the appropriate transceiver, the call lamp and buzzer on the Alarm Panel are switched off. Reception of Distress or Urgency Calls Reception of Distress or Urgency calls, EGCs, and messages are indicated by a slowly flashing distress annunciator and a periodic sound from the buzzer. Furthermore the dimmer will be set to full light intensity. 0736 General Test the Alarm Panel Pressing and holding the Test button will make all light indicators and alarm buttons flash. Pressing any other button while holding the Test button, will sound the buzzer enabling verification of the buttons and the audible indicator. Note that this only tests the Alarm Panel itself and does not involve the connected transceiver unit. For description of system test procedures, please refer to the User’s Manual of each of the system. Mute the alarm sound If the buzzer is on, pressing the Mute button will mute the buzzer until reactivated by a new event. Adjust the light intensity Pressing and holding the Dimmer button will increase or decrease the light intensity in the display. To change between increasing and decreasing, release the button and press it again. The light can be decreased to distinction, but it will always turn to full intensity if any distress indicators turn on, or if the Test button is pressed. 40673 0715 Installation Connector overview VHF 1 VHF 2 DC Supply Option MF/HF Inm-C 1 Inm-C 2 40708 The Alarm Panel will connect to 5 transceiver units (2 × VHF, 2 × Inmarsat-C, and 1 × MF/ HF) each of which is provided a dedicated connector on the rear side of the Alarm Panel. Auxiliary interfaces The AP5065 Alarm Panel provides, through the option connector an auxiliary RS-422 line with a separate Rx and Tx pair, that can be connected to external equipment for monitoring of the Alarm Panel state. Unless specific installation instructions describes otherwise, this interface should not be connected. The power connector also provides a Service interface connection that may be used for future maintenance of the Alarm Panel. Leave this disconnected for normal use. 0736 Interconnecting more Alarm Panels Alarm Panel 1 Inmarsat-C 1 24V 24V VHF 1 40715 Alarm Panel 2 24V 24V Interconnected panels Cable length < 200 meter Alarm Panel 3 24V Inmarsat-C 2 24V VHF 2 MF/HF Up to 3 Alarm Panels can be interconnected and placed in different locations on the vessel. Interconnected Alarm Panels maintain identical light and sound indications, so any operation and behaviour on either Alarm Panel will be reflected on the others (except using the Dimming button and the Test button – which only affects the single Alarm Panel being dimmed or tested). If interconnection is used, the combined set of Alarm Panels still only accepts the same 5 transceiver units, but each transceiver may be connected to either of the interconnected Alarm Panels (e.g., the secondary VHF transceiver can be connected to the VHF 2 connector of any of the Alarm Panel). The interconnection is physically established using a twisted pair cable. The interface is electrically isolated and it must be supplied with 15V power to one of the Alarm Panels. The 15V interface power is taken from a dedicated supply available in the 9-pin power connector. Note that only one of the interconnected Alarm Panels must supply the interface with power in order to maintain the electrical isolation in the installation. 0736 Wiring interconnected Alarm Panels Alarm Panel 1 DC Supply Option 10 22 11 23 12 24 13 25 * 120 INTER L INTER H INTER C INTER S Alarm Panel 2 Alarm Panel 3 Option Option 10 22 10 11 23 11 22 120 23 12 24 12 24 13 25 13 25 * Note: The terminator resistor must match the cable used 120 is a typical value. 40714A DC supply D-sub 9 Designation ID-GND S-RX S-TX ID GND DCDC+ INTER-COUT INTER-SOUT Option D-sub 25 1 and 14 2 and 15 3 and 16 5 and 18 6 and 19 7 and 20 10 and 22 11 and 23 12 and 24 13 and 25 4.8.9 and 17 AUX-TALKER B AUX-TALKER A AUX-TALKER C AUX-LISTENER B AUX-LISTENER A AUX-LISTENER C INTER L INTER H INTER C INTER S NC SERVICE INTERFACE SERVICE INTERFACE SERVICE INTERFACE SUPPLY INPUT SUPPLY INPUT INTERFACE SUPPLY OUT INTERFACE SUPPLY OUT Note: The cable shield must be connected only to the Alarm Panel that powers the interface (Alarm Panel 1 in the wiring diagram). All segments of the interface cable must have connected shields” 0736 Wiring to VHF 1 or VHF 2 40712 Alarm Panel 'VHF' X3 D-Sub 9 way Designation VHF SPARC-BUS D-Sub 15 way SPARC-BUS + SPARC-BUS - GND + 12 V Comment Twisted pair Cable type: 2 x 2 x 0.5 mm² screened, Length: Max. 100m Note: 10 The cable shield must be connected to chassis on the VHF equipment and must be left unconnected at the Alarm Panel.” 0715 Wiring to MF/HF 40711 Alarm Panel 'MF/HF' X4 D-Sub 9 way Designation MF/HF AUX D-Sub 9 way SPARC-BUS + SPARC-BUS - GND + 24 V Comment Twisted pair Cable type: 2 x 2 x 0.5 mm² screened, Length: Max. 100m Note: 0736 The cable shield must be connected to chassis on the MF/HF equipment and must be left unconnected at the Alarm Panel.” 11 Wiring to Inmarsat-C 1 or Inmarsat-C 2 (mini-C) 40710 Alarm Panel mini-C Inm-C Designation D-sub 9 way J302 1,2 GND GND 3,7 Data + Data + 4,5 Data Data 8,9 VCC IN +9V Cable type: min. 2 x 2 x 0.2mm2 screened. Length: Max 250m Comment Twisted pair Note 1: The cable shield must be connected to chassis on the Inmarsat-C equipment and must be left disconnected at the Alarm Panel.” Note 2: If the cable ends at the Alarm Panel, then connect a strap between pin 6 and 7 in order to activate an internal termination resistor. Note 3: For further details refer to TT-3000E mini-C GMDSS system Installation manual (Doc. TT98-122414) Note 4: Connection of a classic Inmarsat-C transceiver (TT-3020C) to the Alarm Panel requires interface TT-3687A installed. For details refer to TT-3687A Alarm Panel adapter Installation & User manual (Doc. TT98-125903) 12 0736 Wiring to 24V DC Supply 40716A Alarm Panel DC Supply Designation D-sub 9 way DC 7 DC + Cable type: 2 x 0.5mm2 screened. Length: Max. 100m INTER-COUT INTER-SOUT Wiring: 2 x 0.2mm2. Length: 0.15 - 0.2m Note: 0736 Alarm Panel Option Connector 12 (Note) 13 (Note) Interface supply used only if interconnecting 2 or 3 alarm panels - refer to page 8. 13 141 100 Outline and dimension 31.5 min. 150 60.5 Space for cable entry 100 128 40674A Mounting option Drilling plan 30 7.5 45 4 x ø 4.5 11.6 86 109.2 Tilting ± 45° 40722 Dimensions are in mm. Weight: AP5065 14 0.8 Kg 0736 Alarm panel with mounting bracket 120 Panel mounting kit (Option) Part no 405065A-920 140 min. 150 Space for cable entry 9.6 Drilling plan Drilling plan 4 x ø5 108 105 20 4 x ø3.5 uns for M3 ISO 14581 Cut out 105 7.5 20 17.5 128 4 pcs M3x30 3 pcs M3x8 40723B 0736 4 pcs M4x30 15 16 TT-98-125065-THR-C Thrane & Thrane A/S Issue: 0736 • info@thrane.com • www.thrane.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 20 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:b88f4818-c86f-4f44-8508-657da6806799 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2007:09:04 12:10:53+02:00 Creator Tool : PageMaker 7.0 Modify Date : 2007:09:11 08:17:48+02:00 Metadata Date : 2007:09:11 08:17:48+02:00 Document ID : uuid:69127a47-1c17-41b3-9842-11ac1c7488aa Format : application/pdf Creator : maj Title : 98-125065-THR-B.pmd Author : majEXIF Metadata provided by EXIF.tools