TiMOTION Technology TH30 Handset User Manual

TiMOTION Technology Co.,Ltd Handset

User Manual

Download: TiMOTION Technology TH30 Handset User Manual
Mirror Download [FCC.gov]TiMOTION Technology TH30 Handset User Manual
Document ID3355850
Application IDmNvus2m2HZPwm+OR0qxp2Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.29kB (341122 bits)
Date Submitted2017-04-12 00:00:00
Date Available2017-04-12 00:00:00
Creation Date2017-04-01 16:57:35
Producing SoftwareFoxit Reader PDF Printer Version 7.1.0.112
Document Lastmod2017-04-12 14:07:45
Document TitleUser Manual

Customer/Project:
Reference:
Sotec
User Guide of TH30 and TRF2
Rev:
Release Date:
Pages
User Guide of TH30 and TRF2
1.
2.
3.
4.
5.
6.
Production Introduction
User’s Manual
Pairing Procedure
Un-Pairing
Product Application
Others
7.
Warning Statement
04/01/2017
1/6
Reference:
Customer/Project:
Sotec
User Guide of TH30 and TRF2
Rev:
Release Date:
04/01/2017
Pages
2/6
1. Product Introduction
TH30 + TRF2 is the latest TiMOTION remote control system with 2.4GHz wireless standard.
The main characteristics are:
Operating distance is 3~7M , waterproof level is IP66 , and fully support TiMOTION T-BUS system
Powered by 2x AA batteries , Customizable membrane
The basic introduction as below:
LED Indicator
Battery cover
LED indicator and reset button
RJ jack for handset and anti-pull lock
Reference:
Customer/Project:
Sotec
User Guide of TH30 and TRF2
Rev:
Release Date:
Pages
04/01/2017
3/6
2. User Manual
A. Battery Replacement
I. Follow the direction of red arrow slide the latch to unlock
battery cover.
II. Put battery cover and lock it after replaced 2×AA
batteries.
Standby time for alkaline batteries:
Conditions
Standby time
No operation
50000hr
Operating continuously 80hr
EX: If operates it 10 times and 1 minute each time per day, TH30 can
sustaining uses for 480 days when new alkaline batteries are used.
Remark:
1.
Note 1: Please put battery cover back and make sure the latch slide back to, in order to make sure waterproof
function working as IP66
B. Definition of the buttons (the information below is an example, all membrane are customizable to fit customer’s
demand )
Please go through part 3 “pairing procedure” before use of TH30.
1, 2For back
button 1-up; button 2-down
3, 4For legs
button 3-up; button 4-down
5, 6For trendelenburg
Button 5-up; button 6-down
7, 8For bed height(Hi-Lo function)
button 7-up; button 8-down
Reference:
Customer/Project:
Sotec
User Guide of TH30 and TRF2
Rev:
Release Date:
Pages
04/01/2017
4/6
3. Pairing Procedure
A. Please put TH30 and TRF2 together with the distance less than
50cm like this picture.
B.
TRF2: Slide open the protection cover
C.
TH30: Keep pressing button 1 and button 2 for 5 seconds to
activate pairing mode. Wait until the LED indicator keeps flashing
slowly.
D. TRF2: Keep pressing reset button till LED indicator flashing 2
times. This indicates the pairing procedure completed. (the LED
indicator on TH30 would flashing 2 times at the same time as
TRF2s’)
E.
TRF2: Please slides protection cover back and make sure it’s fixed
Remark:
Note 1: Please complete pairing procedure within 7 seconds, the pairing mode will be turned off automatically after 7
seconds since it was activated
Reference:
Customer/Project:
Sotec
User Guide of TH30 and TRF2
Rev:
Release Date:
Pages
04/01/2017
5/6
4. Un-pairing procedure
A. Please put TH30 and TRF2 together with the distance less than 50cm like this picture.
B.
Keep pressing button 3 and button 4 for 7 seconds to activate un-pairing mode, un-pairing procedure completed after LED
indicator flashing 3 times
A. Please put TH30 and TRF2 together with the distance less than
50cm like this picture.
B.
Keep pressing button 3 and button 4 for 7 seconds to activate
un-pairing mode, un-pairing procedure completed after LED
indicator flashing 3 times
Remark:
Note 1: Un-pairing procedure only done by TH30.
5. Product Application:
TH30 is for hospital, home beds and nursing beds. The operators will use the wireless handset to operate bed frame, and
avoid contacting with the handset which the patient used.
6. Others
1. Modulation: GFSK
2. Operating frequency: 2420MHz, 2450MHz, 2480MHz
3. Power supply: TH30 (AA battery) / TRF2 (Timotion RJ plug)
4. Input voltage : TH30 (DC 3V) / TRF2 (DC 24〜36V)
5. Environmental Requirements
Operation conditions
Ambient temperature: 10℃ ~ 40℃
Relative humidity range: 30% ~ 75%
Atmospheric pressure: 86KPa~ 106Kpa
Storage and shipping conditions
Ambient temperature: -10℃ ~ 50℃
Relative humidity range: 10% ~ 93%
Atmospheric pressure: 86KPa~ 106KPa
Customer/Project:
Reference:
Sotec
User Guide of TH30 and TRF2
Rev:
Release Date:
04/01/2017
Pages
6/6
7. Warning Statement
FCC Part 15.19 Warning Statement
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING
TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE
MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
FCC Part 15.21 Warning Statement
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY
APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE
USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
FCC Part 15.105 Warning Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
RF warning statement:
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure
condition without restriction.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Creator                         : 
Description                     : 
Title                           : 
Create Date                     : 2017:04:01 16:57:35+08:00
Creator Tool                    : 
Modify Date                     : 2017:04:12 14:07:45+08:00
Metadata Date                   : 2017:04:12 14:07:45+08:00
Keywords                        : 
Producer                        : Foxit Reader PDF Printer Version 7.1.0.112
Document ID                     : uuid:70725395-ea17-4f4b-b686-6a49dceac02a
Instance ID                     : uuid:716c6db8-fb31-4f31-856b-14eaf61dd446
Page Count                      : 6
Author                          : 
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: W6JTH30

Navigation menu