Tong Lung Metal Industry PT2C ELECTRONIC LEVERSET User Manual

Tong Lung Metal Industry Co.,Ltd. ELECTRONIC LEVERSET

User Manual

CARDCARDcardInstruction : After the setup is complete, place the card closeto the sensor (when it beeps once, the registration is complete).The number “1” above represents the order of the card.If the card to be registered is the third card, enter the number“3”, and so on. A maximum of 6 cards can be registered.They can be registered individually or consecutively. 13 12. Voiding designated cardsInstruction : The number “1” above represents the order ofthe card. To void the cards, please enter the order of the card. For example, if the third card is to be voided, enter “3”, andso on. The cards may be voided individually or consecutively.            3. Voiding all cards at the same time14 115Instruction : When it beeps twice, all cards have been voided.SETUP1. Register the card1-1 All cards have been registered in the factory.1-2 The master password must be entered for the registration.      The cards may be registered individually or consecutively      with a maximum of 6 cards.2. Void designated card2-1 The master password is required to void the card.      Voided cards may be reused again after registration. 2-2 The cards may be voided individually or consecutively.3. Void all cards at the same time3-1 The master password is required to void the cards.3-2 All cards may be voided at the same time. The voided      cards may be reuse again after registration.ELECTRONIC KEYPAD LOCKINSTRUCTION MANUALFOR PROXIMITY CARDNotice : The changes or modifications not expresslyapproved by the party responsible for compliance couldvoid the user's authority to operate the equipment. IMPORTANT NOTE : To comply with the FCC RF exposurecompliance requirements, no change to the antenna orthe device is permitted.Any change to the antenna or the device could resultin the device exceeding the RF exposure requirementsand void user's authority to operate the device.This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and(2) this device must accept any interference received,including interference that may cause undesiredoperation.REGISTRATION1. Registering the cardsEnter PCEnter PCEnter PC
45 40 351-3/4" 1-9/16"  1-3/8" 2" 51120x165(mm)Product : Purchase Date : DIGITAL TOUCHPAD LEVER LOCKLimited Warranty Statements1. WarrantyThe manufacturer warrants the Product to be freefrom defects in material and workmanship for a period of 12 monthsfrom the original date of purchase.If you discover a defect in the Product covered by this warranty, we will repair orreplace the item at our option using new or refurbished components.  2. ExclusionsThis warranty covers defects in manufacturing discovered while using theProducts as recommended by The manufacturer rather than occurred by the actof God, and damages caused by misuse, abuse, and unauthorized modification.   3. Limited of LiabilityThe manufacturer will not be held liable for incidental or consequential losses ordamages to any act of God. 4. ReminderService requirement shall subject to the presentation of this warranty cardand defective parts to the manufacturer.The warranty card will not be reissued if lost.  TEMPLATEMark Ø1" (25.4mm) hole atcenter of door edge.Ø  ( )2-1/8" 54mmFit here on door edgeFOR    ( ) 2-3/4” 70mm BACKSETFOR    ( ) 2-3/8” 60mm BACKSETUSER MANUALAttention : Please do not use  the "electronic" screwdriver for installation.ELECTRONICKEYPAD LOCKThis device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference     that may cause undesired operation.
■˙˙˙■■■˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙■■■■Installation Instructions ..................................P.1Replace the old lock with the new one Install the new lock on the new door Starting the installation ..................................P.4Operation Interface .........................................P.7Specifications and Functions ........................P.8Code Setup .....................................................P.11Notifications ...................................................P.11Function Setup ..............................................P.12Troubleshooting ............................................P.14Indentifying the door handing Power supply Low battery indicationKeypad light indication Audio indication Programming Code (PC)User Code (UC)Delete individual user codeDelete all user codes at onceInvalidate user codes temporarilyCreate the one-time user codeRestore default PC & UCUnlockLockAutomatic lockPassword protection functionBacklit functionTable of ContentsP.1P.1P.2P.8P.8P.8P.8P.8P.9P.9P.9P.9P.9P.9P.10P.10P.10P.10P.10
12The distance between the edge of the door to the center ofthe hole is the latch backset. The adjustable latch providestwo choices of backsets 2-3/8" (60mm) and 2-3/4" (70mm).Change the backset for the latch according to the illustration.For adjustments please refer to the following illustrations.Note : The correct direction for the           cam is shown as the circle on           the left side. acbLatch face platePrior to installation, please make sure that the faceplate is appropriate for the latch. Drive-in latchInstallation of the round face plateReplace the old lock with the new oneTo replace the old lock with this product on the same door, please confirm thebackset for the latch and the specifications for the face plate match. Please alsorefer to the following instructions to adjust the backset and face plate to match theexisting door's specifications.Install new lock on the new doorTo install this product on a new door, please go through thefollowing steps to drill the hole.Check that the lever direction meets the door handing. If not, please switch thelevers by following steps. ■Installation Instructionsa. The illustration shows a backset of   ( ).b. Pull the cam all the way to the right, to adjust backset to 2-3/4" (70mm).c. To restore back to 2-3/8" (60mm), push the adjustable sleeve all the way to    the left.2-3/8" 60mmReplace the face plate1. Use the slotted screwdriver to pry open the    face plate and the lock body.2. Install the appropriate face plate onto the latch    body.Align the round face plate to the head of the latch,and lock it into position.Mark The Door With TemplateSelect the height and backset as desired on the doorface ; use the TEMPLATE as an indication to mark thecenter of the circle on the door face and the center ofthe door edge.Drill HolesUsing the marks as a guide to drill a hole Ø2-1/8"(54mm) through the door face for the lockset, thena hole of Ø1" (25.4mm) for latch.Identify Door HandingFace the door from outside, the door is left handed if the hinge is on the left-handside of the door, whereas the door is right handed if the hinge is on the right-handside of the door.InteriorExteriorDoor Hinge(Left Handed) (Right Handed)Before installing this product, please confirm the door openingdirection to make sure that the lever is installed in the correctdirection.
3cab4a b ca b c d■Start the installation1. Install latcha. Insert the latch and lay the faceplate against the door edge.     Use a pencil to mark its perimeter, then take out the latch.b. Chisel out the portion you've marked with pencil for about 5/32" (4mm) deep.    Score the area within the borders as clearly and precisely as possible.    Ensure the plate can fit flush with the door edge surface.c. Insert the latch and tighten it with screws.     Be sure the holes for through-bolts (next to the adjustable cam) are horizontally    aligned.d. It is not necessary to chisel the door edge for the faceplate installation if you use    the drive-in latch.    You may install it into the edge bore directly, but be sure the bevel should face    the outside assembly.a. Half-close the door to lay the latchbolt against the door frame.    Mark the position of faceplate as an indication.    Place the strike against the door frame and mark its perimeter.    Make sure the center of strike is perfectly aligned with the center of faceplate.b. Drill a ø1" (25.4mm) hole with 1/2" (13mm) depth on the center of strike outline.    Then use the chisel to scrape out the door frame for 1/16" (1.6mm) deep within    the traced outline.     Make sure to chisel deep enough to allow the strike to lay flush with the frame    surface.c. Insert the strike and tighten it with screws.     Note : please use “tapping screws” for a metal door.2. Install strikeChange Lever Handinga. Make sure that the lock is unlocked.    (The spindle is perpendicular.) Remove the    protection sleeve of the exterior lock unit.    Rotate the exterior lever by 180 degrees and    return the protection sleeve to its original position.b. Insert the dismantle tool into the hole on the    neck of the exterior lever and press down,    and pull the lever out at the same time. From the    interior, just remove the lever and switch the    interior and exterior levers.c. Push in and fasten the lever. Make sure that the     lever is correctly in place, and test the lock by    turning it to make sure it's functioning properly.ProtectionsleeveProtectionsleeveExterior leverExterior leverInterior leverRemove the interior leverUse the thumb and index finger to push against thelock body while holding and pulling the lever back.Meanwhile, insert the dismantle tool into the holeon the side of the lever, press down, and thelever can be pulled out.
5a b6bca3. Install the exterior lock bodya. Fit the spindle   through the square cam of the latch.b. Fit the cable through the cross bore above the latch.verticallySpindleCableThe spindle must be vertical.4. Install the interior mounting platea. Pass the cable through the cable hole on top of the interior plate. Then fasten the    interior plate with screws.b. Examine whether the exterior lock unit and the interior plate are tilted. If so,    please loosen the screws for adjustment, and re-fasten the screws.c. Wood screws or self-tapping screws may be used if needed.    (Wood screws are used for wooden doors, and self-tapping screws are used for    metal doors to increase bonding.)Interior plateCable CableFasten screwsWood screws orself-tappingscrews5. Install the interior lock bodya. Push the battery cover upward.c. Install 4 AA Alkaline batteries and close the battery cover. Installation is complete.b. Connect the interior and exterior cables. Align the interior lock unit to the spindle    and push it in (the turn-piece is horizontal). When the interior lock unit is flush    with the door, fasten with screws.     If the interior lock body cannot be flush with the door, please push the cable into    the cross bore.InstallationscrewsBatterycover
78 Confirm buttonFor function setup. Number buttonsTo enter user codes. Each codemust be 4-10 digits long. To be locked and unlocked withthe key. Battery coverPush it upward and outward toreplace the batteries.CylinderUses 4 AA Alkaline batteries. Indication lightWhen the light is lit continuously, itmeans the unit is in operation.When it's blinking, it means lowbattery and the batteries need tobe replaced. Lock and unlock from the interior. Lock/unlock button Lock and unlock from the exterior. Battery holderTurn-piece■Specifications and Functions1. Power supplyIf the password is entered incorrectly more than 5 times, the system will initiate itsprotective mode and stop functioning.5. Programming Code (PC)-1 The default programming code is “0000”. It is recommended that the user       change the programming code during initial installation.5-2 There is only one programming code and is 5-3 The programming code cannot be used to unlock the door.5-4 The programming code 5-5 The programming code can be changed anytime as needed.   DC6V, 4 AA, 1.5V Alkaline batteries. (not included)2. Low battery indication2-1 During operation, if the red light on the battery cover blinks and 10 short beeps      are heard, it means that the battery is low. The batteries need to be replaced      immediately. 2-2 All settings will remain active and won't change or disappear even if the      battery is down.2-3 When the batteries are fully drained, the system can still be locked or unlocked      manually with the key.3. Keypad light indication4. Audio indication4-1 1 short beep means the operation is normal.4-2 2 long beeps mean the setting is correct.4-3 3 short beeps mean operational error.4-4 3 long beeps mean the default password has been restored.4-5 5 short beeps mean password operational error. The system will initiate the         protective mode and stop functioning.4-6 10 short beeps mean the battery is low.5used to set all functions.must be 4-10 digits in length.■Operational interface
9106. User Code (UC)6-1 The default user code is “1234”. During initial installation, delete the default user      code, and then set the new user code.6-2 A total of 6 user codes can be saved.6-3 The user code can only be used to unlock the door and 6-4 The user code 6-5 The user code can be deleted or added at anytime as needed.7-1   The same user code can be reset after being      deleted.7-2 The programming code is needed to delete 8. Delete all user codes8-1   The original user codes can be reset again.8-2 After deleting all user codes, the automatic lock and the     button lockup      functions set previously will automatically be disabled. The user code      8-3 The programming code is required to delete 9. Temporarily  user code9-1 This will temporarily disable all user codes. The automatic lockup and keypad      lockup functions that were set previously will automatically be disabled. A key      must be used to lock and unlock the door.9-2 To restore the code function and other electronic functions, repeat the steps for      “Temporarily   user code”.10.   one-time user code10-1 After the one-time user code is entered and used, it is   and won't be        able to open the door again.10-2 The same one-time user code can be set repeatedly.10-3 The programming code is needed to set other functions.must be 4-10 digits in length.User codes can be deleted individually.individual codes.All user codes can be deleted at once.door can only be locked      or unlocked with a key. The original functions will be restored once the is set.all user codes.disable disableCreatedisabledfor setup.7. Delete individual user code11. Restore the default PC & UCto delete12. Unlocka registered12-2 To unlock with the keypad1. Place the hand within 2 cm of the keypad or press any key once to light up the             keypad.          2. 4 numbers will appear on the keypad. Press them in any order.          3. Enter the user code.  13. LockThe door can be locked fromthe inside14. Automatic lockup14-1 The timer (10-99 seconds) of automatic lockup can be set up by the user as        needed. (The default timer is 30 seconds after the system is unlocked.)14-2 To disable the automatic lockup, please repeat the steps for “Automatic lockup”.15. Code protectionIf the user code is entered incorrectly over 5 times, the system will initiate theprotective function and disable the keypad for 45 seconds.16. BacklightWhen the hand is within 2 cm of the keypad, the backlight will light up for about 5seconds, making it easy to operate lockset in the dark.          Use this function when forgetting the programming code or   all settings.12-1 The door can be unlocked by entering   user code or the key from        outside, or pressing the lever down / turning the knob from inside.        4. Press the     button.             When the light for the key goes out, the system is unlocked.When the keypad lights up, the user may press the keypad, press     button or usethe key and automatic lockup function to lock the door.  by turning the interior turn-piece.
1112■Code setupAll setup should be done when the system is unlocked.Turn keypack backlight on by approaching your hand orpressing a button, then proceed with setup.1. During initial installation, it is recommended to change the default    programming code (0000), delete the default user code (1234), and add    the new personal user code prior to setting up other functions.  2. Two long beeps indicate that the input is correct.    When the keypad blinks three times with three short beeps, the input is    incorrect. 3. During the function setup, if it takes longer than 6 seconds to finish any    step, the system will automatically leave the program. 4. This product can be operated with the keypad or key.5. Please refer to the instructions for function setup. ■Notification1. Alkaline batteries are recommended to maintain stable and prolonged    power.2. Do not mix the alkaline batteries with regular zinc-carbon batteries    and avoid mixing batteries of different brands.3. Do not use any chemicals or add any lubricants when cleaning the lock, to    avoid damaging the panel and coating. ■Function setupAdd new user codeInstruction : A total of 6 user codes with a combination of 4 to 10 digits can be                   set up. Delete individual user codeThe UC tobe deletedDelete all user codesInstruction : When all user codes are deleted and no new user code is set up, all                    electronic lockup functions will be disabled. (The electronic functions                    will be restored when a new user code is set.) During this time, the                    door must be locked or unlocked manually with a key.Change programming codeAutomatic lockupInstruction : The default setup for the automatic lockup timer is 30 seconds.                    To modify the timer for the automatic lockup, please refer to the                    instructions for “Automatic lockup timer”. To cancel the automatic                    lockup, please repeat the setup procedure for “Automatic lockup”.Enter PC New UC12345■  ■      PC (Programming code)UC (User code)Confirm buttonEnter PCEnter PCEnter PCEnter PCNew PC
1314■TroubleshootingScenario 1After the installation is complete and the batteries are inplace, none of the buttons are responsive. (No sound, and no backlight)  Cause : Issues with batteries or the wiring.Solution : Replace the batteries or make sure the batteries are installed                correctly. Please check whether the cable from the interior lock                unit is connected correctly.Scenario 2 the programming code while , the error message   after pressing theconfirm button. (The light blinks three times with three short beeps.)Cause : Function setup   locked. Solution : Unlock the door by turning the turn-piece from the interior lock                unit or with a key from the exterior.When entering setup of otherfunctions appearswith the doorTemporarily   user codesdisableUse one-time user codeInstruction : When all user codes are temporarily   all electronic functions will                    be temporarily   as well. The door must be locked or unlocked                    manually with the key. To restore user code functions, please                    repeat the setup process for “Temporarily  user code”.disabled,disableddisable Enternew UCRestore factory defaultInstruction : After removing the batteries, touch the keypads for three seconds and                   re-install the batteries.                   When the numbers 2, 5, 8, 0 are displayed on the keypad, press the                   four numbers in any order until all numbers disappear.89Instruction : the timer can be set from 10 to 99 seconds.Automatic lockup timer6Scenario 3The door will not lock after pressing the      button becausethe lever was turned before the motor had finished operating.Cause : The lever or the knob is turned too early while the motor is not yet             operating.Solution : Wait for the end of the motor operating sound(the keypad light is                off), and then press the     button again to execute the lockup                function. ■  ■      PC (Programming code)UC (User code)Confirm buttonEnter PCEnter PCEnter PCEnter a two-digitnumber (10~99)Instruction : Once this user code is entered and used, it   and unable                    to open the door again. However, the same one-time user code can                    be set again.is disabled