Topcon America 5434 Wireless Excavator System User Manual X 22 User s Manual
Topcon America Corporation Wireless Excavator System X 22 User s Manual
Contents
- 1. Users Manual
- 2. Installation Manual
Users Manual
8 $ %XCAVATOR )NDICATE 3YSTEM 5SERlS -ANUAL P O S I T I O N I N G S Y S T E M S X-22 Excavator Indicate System User’s Manual Part Number 7010-1020 Rev A ©Copyright Topcon Positioning Systems, Inc. June, 2011 All contents in this manual are copyrighted by Topcon. All rights reserved. The information contained herein may not be used, accessed, copied, stored, displayed, sold, modified, published, distributed, or otherwise reproduced without express written consent from Topcon. ECO#4152 TOC Table of Contents Chapter 1 Introduction .......................................................... 1-1 Operating Principle .......................................................... 1-1 Updating the Software ..................................................... 1-2 How to Update the Software ..................................... 1-2 Chapter 2 Getting Acquainted .............................................. 2-1 The Digging Window ...................................................... Target ball ................................................................. Bucket Height ............................................................ Top View of Machine ............................................... Bucket View .............................................................. Length ....................................................................... Side View of Machine ............................................... Digging Window Buttons ......................................... Menu ................................................................... Reference ............................................................ Swap Point .......................................................... Length Referencing ............................................ Measure .............................................................. Verify .................................................................. Work/Project ....................................................... Graphical Settings ............................................... Types of Work/Projects .................................................... Flat Plane ................................................................... Single Slope .............................................................. Dual Slope ................................................................. Trench ....................................................................... Profile ........................................................................ Channel ..................................................................... Embankment ............................................................. P/N 7010-1020 2-1 2-2 2-2 2-3 2-4 2-5 2-5 2-6 2-6 2-6 2-7 2-7 2-7 2-7 2-8 2-8 2-9 2-10 2-11 2-12 2-13 2-14 2-15 2-16 Table of Contents Bucket-defined ........................................................... 2-17 Chapter 3 X-22 Setup ............................................................ 3-1 Work/Project Settings ....................................................... Reference Height ....................................................... Gradient/Slope in Lengthways Direction .................. Gradient/Slope to the Side ......................................... Direction of Slope ...................................................... Referencing ...................................................................... Referencing with Benchmark .................................... Referencing with Laser .............................................. Digging Slopes ................................................................. Moving the Undercarriage ................................................ Option 1: New Reference .......................................... Option 2: Retain the Same Height ............................. Option 3: Swap Point Function .................................. Graphical Settings ........................................................... Measurement Point of Bucket ................................... Visible Elements ................................................. Brightness of Digging Window .......................... Angular Difference for Bucket Warning ............. Working Area ...................................................... Focus ................................................................... Color Warning ..................................................... Size of Excavator ................................................ Position of Excavator .......................................... Appearance of Excavator .................................... Sound Settings ........................................................... Height alarm ........................................................ Using the Compass ........................................................... Speed of Sensors .............................................................. Sensitivity .................................................................. Damping .................................................................... 3-1 3-1 3-2 3-2 3-2 3-2 3-3 3-4 3-6 3-8 3-8 3-8 3-9 3-9 3-10 3-10 3-10 3-10 3-10 3-11 3-11 3-11 3-11 3-11 3-12 3-12 3-12 3-13 3-13 3-14 Chapter 4 Troubleshooting .................................................. 4-1 ii X-22 User’s Manual Table of Contents Appendix A Specifications ....................................................... A-1 X-22 Sensor ..................................................................... A-1 Appendix B Safety Warnings ................................................... B-1 General Warnings ............................................................ B-1 Sensor Warnings .............................................................. B-2 Usage Warnings ............................................................... B-3 Appendix C Regulatory Information ........................................ C-1 FCC Compliance ............................................................. C-1 Community of Europe Compliance ................................. C-2 WEEE Directive .............................................................. C-2 Appendix D Warranty Terms .................................................... D-1 P/N 7010-1020 iii Table of Contents Notes: iv X-22 User’s Manual Preface Preface Thank you for purchasing your Topcon X-22 2D Excavator Indicate System, product or accessory (the “Product”). The materials available in this manual (the “Manual”) have been prepared by Topcon Positioning Systems, Inc. (“TPS”) for owners of Topcon products. This Manual is designed to assist owners with the use of software (the “Software”) to be used with the Product and its use is subject to these terms and conditions (the “Terms and Conditions”). NOTICE Please read these Terms and Conditions carefully. Terms and Conditions USE This product is designed to be used by a professional. The user should have a good knowledge of the safe use of the product and implement the types of safety procedures recommended by the local government protection agency for both private use and commercial job sites. COPYRIGHT All information contained in this Manual is the intellectual property of, and copyrighted material of TPS. All rights are reserved. You may not use, access, copy, store, display, create derivative works of, sell, modify, publish, distribute, or allow any third party access to, any graphics, content, information or data in this Manual without TPS’ express written consent and may only use such information for the care and operation of your product. The information and data in this Manual are a valuable asset of TPS and are developed by the expenditure of considerable work, time and money, and are the result of original selection, coordination and arrangement by TPS. P/N 7010-1020 ix Preface TRADEMARKS Topcon®, X-22™, and Topcon Positioning Systems™ are trademarks or registered trademarks of TPS. Other product and company names mentioned herein may be trademarks of their respective owners. DISCLAIMER OF WARRANTY EXCEPT FOR ANY WARRANTIES IN AN APPENDIX OR A WARRANTY CARD ACCOMPANYING THE PRODUCT, THIS MANUAL AND THE PRODUCT ARE PROVIDED “AS-IS.” THERE ARE NO OTHER WARRANTIES. TPS DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR USE OR PURPOSE. TPS AND ITS DISTRIBUTORS SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN; NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE OR USE OF THIS MATERIAL OR THE PRODUCT. SUCH DISCLAIMED DAMAGES INCLUDE BUT ARE NOT LIMITED TO LOSS OF TIME, LOSS OR DESTRUCTION OF DATA, LOSS OF PROFIT, SAVINGS OR REVENUE, OR LOSS OF THE PRODUCT’S USE. IN ADDITION TPS IS NOT RESPONSIBLE OR LIABLE FOR DAMAGES OR COSTS INCURRED IN CONNECTION WITH OBTAINING SUBSTITUTE PRODUCTS OR SOFTWARE, CLAIMS BY OTHERS, INCONVENIENCE, OR ANY OTHER COSTS. IN ANY EVENT, TPS SHALL HAVE NO LIABILITY FOR DAMAGES OR OTHERWISE TO YOU OR ANY OTHER PERSON OR ENTITY IN EXCESS OF THE PURCHASE PRICE FOR THE PRODUCT. LICENSE AGREEMENT Use of any computer programs or software supplied by TPS or downloaded from a TPS website (the “Software”) in connection with the computer constitutes acceptance of these Terms and Conditions in this Manual and an agreement to abide by these Terms and Conditions. The user is granted a personal, nonexclusive, non-transferable license to use such Software under the terms stated herein and in any case only with a single system or single computer. You may not assign or transfer the Software or this license without the express written consent of TPS. This license is effective until terminated. You may terminate the license at any time by X-22 User’s Manual Terms and Conditions destroying the Software and Manual. TPS may terminate the license if you fail to comply with any of the Terms or Conditions. You agree to destroy the Software and manual upon termination of your use of the computer. All ownership, copyright and other intellectual property rights in and to the Software belong to TPS. If these license terms are not acceptable, return any unused software and manual. CONFIDENTIALITY This Manual, its contents and the Software (collectively, the “Confidential Information”) are the confidential and proprietary information of TPS. You agree to treat TPS’ Confidential Information with a degree of care no less stringent that the degree of care you would use in safeguarding your own most valuable trade secrets. Nothing in this paragraph shall restrict you from disclosing Confidential Information to your employees as may be necessary or appropriate to operate or care for the product. Such employees must also keep the Confidentiality Information confidential. In the event you become legally compelled to disclose any of the Confidential Information, you shall give TPS immediate notice so that it may seek a protective order or other appropriate remedy. WEBSITE; OTHER STATEMENTS No statement contained at the TPS website (or any other website) or in any other advertisements or TPS literature or made by an employee or independent contractor of TPS modifies these Terms and Conditions (including the Software license, warranty and limitation of liability). SAFETY Improper use of the product can lead to injury to persons or property and/or malfunction of the product. The product should only be repaired by authorized TPS warranty service centers. Users should review and heed the safety warnings in an Appendix. MISCELLANEOUS The above Terms and Conditions may be amended, modified, superseded, or canceled, at any time by TPS. The above Terms and Conditions will be governed by, and construed in accordance with, the laws of the State of California, without reference to conflict of laws. P/N 7010-1020 xi Preface Manual Conventions This manual uses the following conventions: Example Description FileExit Tap the File menu and tap Exit. Enter Indicates the button or key labeled Enter. Topo Indicates the name of a dialog box or screen. Notes Indicates a field on a dialog box or screen, or a tab within a dialog box or screen. TIP NOTICE xii Supplementary information that can help you configure, maintain, or set up a system. Supplementary information that can have an affect on system operation, system performance, measurements, personal safety. X-22 User’s Manual Introduction Introduction Congratulations on your new X-22 System. You are now ready for quicker, safer and more accurate work with your new workmate, X22. This manual contains descriptions of the user interface and ideas for working with the X-22 System. But don’t let this limit your use of X22. X-22 can almost certainly be used in ways we have not thought of or described in this manual. When on site, you are the expert – all we have done is offer you the best workmate an excavator driver could wish for. Enjoy your work! Operating Principle The X-22 software was designed to give you all necessary information for the current job, just by glancing at the screen. Some of the information, such as the height alarm, is also provided by X-22 in the form of sound signals. To give you this information X-22 needs your help. To get started, you first have to tell X-22 what type of work or project you intend to carry out. You then tell X-22 where this work is to be done by referencing. With this complete, the excavator is able to sit with its undercarriage in one place while you dig and swing the superstructure to your heart's content. X-22 has complete control over where the machine is in relation to the project. If the undercarriage moves, for instance, because you have transferred to a new location, you must tell X-22 this by referencing again. Once referencing is complete, continue digging, and X-22 continues to make the right measurements. This is how daily work proceeds, and in this way X-22 helps you by displaying the excavator in terms of work, height, length, slope and P/N 7010-1020 1-1 whatever else you need to carry out your work to a centimeter’s precision. Updating the Software You can see which version of the software you have in the top righthand corner of the Main Menu (e.g. “v1.6.0.1”). You can also check if you have the latest version by visiting www.topconpositioning.com How to Update the Software 1. To download the “X-22_Update.exe” program onto your computer, laptop or workstation using Windows, click the link to the latest program version on www.topconpositioning.com . Contact your dealer if you have not been given a username and password. 2. Insert a USB flash drive into the computer. 3. Run the “X-22_Update.exe” program. 4. Click Next. Figure 1-1. Updating the X-22 Software. 1-2 X-22 User’s Manual Introduction 5. Click Browse..., and select the location of USB flash drive. Then, click Install to allow the program to copy the necessary files to the USB flash drive, after it checks for enough free space. When the program is finished, you have the option of reading the release notes. Figure 1-2. Updating the X-22 Software. 6. Plug the memory stick into the X-22 Display, and select Main menu Setup Hardware Computer Update software. Figure 1-3. Updating the X-22 Software. P/N 7010-1020 1-3 Notes: 1-4 X-22 User’s Manual Chapter 2 Getting Acquainted The following chapter describes the basic features of the X-22 excavator indicate system software. The Digging Window Figure 2-1. Digging Window In the Digging Window, you will find all the information you need for digging. You can also choose what you would like to see displayed for optimal adaptation of the screen to you and your needs. This chapter describes what you will see in the Digging Window and how you can use it. P/N 7010-1020 2-1 Target ball On the left side of the Digging Window (Figure 2-1 on page 2-1) you will see the Target Ball . This functions as a zoom. As the bucket tip approaches the digging depth, the ball begins to move. When the Target Ball is in the center of the circle, the bucket tip is exactly at the desired digging depth. The two horizontal lines show the working area. Bucket Height The top left-hand corner of the Digging Window (Figure 2-2)shows the vertical distance from the measurement point on the bucket tip to the entered digging depth. Figure 2-2. Bucket Height 2-2 X-22 User’s Manual Getting Acquainted Top View of Machine At the top right-hand of the Digging Window (Figure 2-3) the excavator and the project are viewed from above. This can be very helpful for returning to a lengthways direction, for example in the case of a trench. Figure 2-3. Top View P/N 7010-1020 2-3 Bucket View In the top center of the Digging Window (Figure 2-4) the bucket is displayed as viewed from the driver’s cab with the project below. This window is particularly useful if you have a tilt bucket and tilt sensor. It shows both the tilt angle on the bucket and the gradient/ slope of the project perpendicular (90 degrees) to the direction of the boom. The bucket in the window can also change color to show that the tilt angle on the bucket is too small, too large or correct for the project. Figure 2-4. Bucket View 2-4 X-22 User’s Manual Getting Acquainted Length You can also bring up the length from a given point to the bucket tip. The length will be shown in yellow text under the bucket height. Length is a separate referencing system which measures the horizontal distance from the length referencing point to the bucket tip. The distance is measured with respect to the circle center on the undercarriage, so that the measured length does not alter as the superstructure swings around. This can be very useful when laying pipes for example. Press Graphics and then choose Visible elements to turn on length referencing. Side View of Machine Being able to see the excavator from the side during the project is probably the most important function for you as driver, and is therefore the main focus in the Digging Window. Figure 2-5. Side View P/N 7010-1020 2-5 Digging Window Buttons The menu in the Digging Window has a large number of functions that are just a click away. Menu This button opens and closes the Menu. Reference Benchmark If you have chosen benchmark as your referencing method, the reference button will show the image of a bucket. Laser If you have chosen laser as your referencing method, the reference button will show the image of a laser. Press the reference button to perform a new reference, and follow the on-screen instructions. 2-6 X-22 User’s Manual Getting Acquainted Swap Point Press this button (Move) to use the swap point function and follow the on-screen instructions. Length Referencing Place the bucket tip on the reference point and press this button to start measuring the horizontal distance from the reference point to the bucket tip. This button only appears on the Menu when length referencing is turned on. Press Graphics and then choose Visible elements to turn on length referencing. Measure Place the bucket tip on the reference point and press this button to start measuring length, height, distance and gradient/slope from the reference point. Press the button once more to return to the project you are working on. Verify Pressing this button gives you access to a procedure which lets you verify whether X-22 is measuring accurately or not. If it is not doing so, you can also press Verify, and select Troubleshooting to identify and correct any errors. P/N 7010-1020 2-7 Work/Project Press this button to view and alter settings on the project you are working on. If you wish to start a new project, this can also be done here. Graphical Settings By pressing this button you can change what is displayed in the Digging Window and how it is displayed. Sound Settings Press this button to change when X-22 will give a sound signal during digging. The settings for the height alarm are also located here. NOTICE 2-8 The sound integrated in X-22 is very quiet. External beeper with a loud sound can be purchased from your dealer. X-22 User’s Manual Getting Acquainted Types of Work/Projects X-22 allows you to select the following types of work: • Flat plane • Single slope • Dual slope • Trench • Profile • Channel • Embankment • Bucket-defined slope The type of work is also called a project. The following sections contain a description of the different projects and what settings need to be entered. P/N 7010-1020 2-9 Flat Plane Figure 2-6. Flat Plane Surface A flat plane is a horizontal surface without gradient in any direction. This means you only need to set two things in X-22: • The referencing method • The reference height (vertical distance from reference point to digging depth) NOTICE 2-10 In flat-plane digging the Digging Window does not show the machine from above. On a flat plane the vertical distance from the bucket tip to the digging depth is the same whatever direction the superstructure is facing. X-22 User’s Manual Getting Acquainted Single Slope Figure 2-7. Single Slope Surface A single slope is a surface with a gradient in one defined direction. In X-22 you must set the following to work on single slopes: • The referencing method • The reference height (vertical distance from reference point to digging depth) • The gradient/slope • Direction of gradient/slope (if compass is turned on) P/N 7010-1020 2-11 Dual Slope Figure 2-8. Dual Slope Surface A dual slope is a surface with a gradient both lengthways and sideways. In X-22 you must set the following to work on dual slopes: • The referencing method • The reference height (vertical distance from reference point to digging depth) • Gradient/slope in lengthways direction • Gradient/slope to the side • Direction of gradient/slope in lengthways direction (if compass is turned on) NOTE 2-12 If you enter the sideways gradient as zero, the project will be the same as a single slope. X-22 User’s Manual Getting Acquainted Trench Figure 2-9. Trench A trench is a single slope of limited width. The limitation lies in the width of the trench base and the walls sloping up from the base. A trench has the following settings: • The referencing method • The reference height (vertical distance from reference point to trench bottom) • Gradient/slope in lengthways direction • Width of trench • Gradient/slope of trench walls • Direction of gradient/slope in lengthways direction (if compass is turned on) P/N 7010-1020 2-13 Profile Figure 2-10. Profile A profile consists of two horizontal surfaces of different height with a single slope between them. In X-22 you must set the following to work on a profile: • The referencing method • The reference height (vertical distance from reference point to digging depth) • Gradient/slope in lengthways direction • Height from starting point to base of profile • Direction of gradient/slope in lengthways direction (if compass is turned on) 2-14 X-22 User’s Manual Getting Acquainted Channel Figure 2-11. Channel Surface A channel consists of three horizontal surfaces with single slopes between them as shown on the illustration opposite, and has the same gradient on both sides of the channel base. With a channel the following settings must be entered: • The referencing method • The reference height (vertical distance from reference point to digging depth) • Gradient/slope in lengthways direction • Length of channel base • Height from starting point to base of channel • Direction of gradient/slope in lengthways direction (if compass is turned on) P/N 7010-1020 2-15 Embankment Figure 2-12. Embankment Surface An embankment consists of three horizontal surfaces with single slopes between them as shown on the illustration opposite, and has the same gradient on both sides of the embankment top. With an embankment the following settings must be entered: • The referencing method • The reference height (vertical distance from reference point to digging depth) • Gradient/slope in lengthways direction • Length of top of embankment • Height from starting point to top of embankment • Direction of gradient/slope in lengthways direction (if compass is turned on) 2-16 X-22 User’s Manual Getting Acquainted Bucket-defined Figure 2-13. Bucket-defined Single Slope Surface Bucket-defined is used to indicate a single slope using the bucket tip. This can be useful, for instance when forming a single slope up to the foundations of a garage. By referencing the bucket tip to two different points, X-22 will calculate the gradient, direction of gradient and digging depth and store these settings in the same way as for a single slope. NOTICE P/N 7010-1020 Do not rotate the superstructure until you have referenced both points. 2-17 Notes: 2-18 X-22 User’s Manual Chapter 3 X-22 Setup The following chapter describes how to setup the X-22 software. Work/Project Settings Many of the settings entered are the same for the different projects. Selecting a new project in X-22 guides you through the setup procedure for these settings using images and text. This chapter also gives a detailed description of the most important project settings. Reference Height The reference height is the vertical distance from the reference to the digging depth. If you use a rotating laser for referencing, the laser plane will be the reference and if you use the bucket tip for referencing, the benchmark you place the bucket tip on will be the reference. NOTICE Notice that the reference height will be positive if the digging height lies below the reference. A reference height of 1.0 m (3.28 ft.) will thus result in a digging depth of 1.0 m (3.28 ft.) below the reference. You can use the reference height actively when working on a project. Say you have set the reference height to 1.0 m and have finished levelling out a site foundation. If your next task is to lay 10 centimeters of crushed stones on the foundation base, you can change P/N 7010-1020 3-1 the reference height to 0.9 m and use X-22 to check that the layer of crushed stones has the correct height/thickness. If you have been given the heights as elevations and have benchmarks at a particular elevation, you can use X-22’s integral calculator to work out the reference height. Gradient/Slope in Lengthways Direction This is the gradient in the direction of the boom when Direction of slope is entered. Gradient/Slope to the Side This applies only to Dual slope and is the gradient perpendicular (90 degrees) to the lengthways direction. For all other projects, the gradient/slope to the side is zero. Direction of Slope This is the lengthways direction of the slope and is indicated by pointing the boom in the lengthways direction of the slope. When you press OK on the screen, X-22 stores this direction using the compass. Referencing X-22 always knows where the bucket tip is in relation to the rotation center of the undercarriage, but in order to know where the rotation center and thus the bucket tip is in relation to the project, X-22 must be referenced. This is done with a benchmark or a rotating laser. NOTICE 3-2 If the excavator is standing in loose material, the machine may creep. X-22 will not notice this and you should therefore re-reference if the machine is creeping a great deal. X-22 User’s Manual X-22 Setup Once you have created a new project you are automatically invited to reference when you go into the Digging Window. To perform a new reference, press Reference in the Digging Window menu. Referencing with Benchmark A benchmark is a point with a known height in relation to the digging depth of your current project. NOTICE If you have chosen Profile, Channel or Embankment, the benchmark must also have a known position in relation to the project. See the screen images for the current project for further details. Figure 3-1. Benchmark Reference Place the bucket tip on the benchmark, and press OK. P/N 7010-1020 3-3 Referencing with Laser X-22 can also be referenced by detecting the laser ray from a rotating laser with the laser receiver on the arm sensor. NOTICE The laser must be set with exactly the same gradient/slope and direction as entered for the project in X-22. During referencing, the screen will show where the laser ray has hit the laser receiver. Figure 3-2. Laser Reference Press OK when the laser ray touches the center point. 3-4 X-22 User’s Manual X-22 Setup NOTICE The advantage of a rotating laser is that it can cover large areas with very high accuracy. You avoid having to use many benchmarks and avoid the risk of losing accuracy when moving the excavator. Contact your dealer for offers of X-22 quality lasers. To find the laser plane as quickly as possible, you can first move the arm relatively quickly through the area you expect to find the laser ray in, while simultaneously watching the screen for a hit. When the laser ray hits its target, go back to the correct height and adjust until the laser ray touches the center. Figure 3-3. Laser Reference P/N 7010-1020 3-5 Digging Slopes All projects except Flat plane include surfaces with a slope. The gradient/slope is entered in X-22 as a percentage (%), unless Bucket-defined project is selected. If the gradient/slope has been specified as a ratio (e.g. 1:8) or in degrees (e.g. 12.5) you can use X22’s integral calculator to translate these values into percentages. Enter the direction of the slope by pointing the boom in the lengthways direction of the slope. NOTICE A slope has the gradient you entered, in the lengthways direction entered. Using its compass, X22 constantly calculates the gradient in the boom direction as the superstructure swings around. This applies to all projects with a slope. This is illustrated by a single slope in Figure 3-4 on page 3-7. In this image, the superstructure is in line with a single slope of 30% gradient. In Figure 3-5 on page 3-7, the superstructure has rotated through 90 degrees. As can be seen from the images, the gradient/slope in the boom direction displayed under the machine changes from 30% to 0% (zero). 3-6 X-22 User’s Manual X-22 Setup Figure 3-4. Example of 30% Single Slope in Digging Window Figure 3-5. Example of 0% Single Slope in Digging Window P/N 7010-1020 3-7 Moving the Undercarriage When you have referenced and finished digging at the point where the undercarriage is standing and need to move to a new location, you will need to inform X-22. The following describes three ways you can do this. Option 1: New Reference After moving the undercarriage to a new position you can rereference to a benchmark or laser plane. Option 2: Retain the Same Height If you have been digging down to the desired depth, you can continue referencing this digging depth instead of the benchmark or laser plane you started with. You can do this be altering the reference height in the project to zero, selecting benchmark as the referencing method and then referencing the bucket tip on the excavated area after moving the machine. 3-8 X-22 User’s Manual X-22 Setup Option 3: Swap Point Function Figure 3-6. Swap Point Function The swap point function is available for projects Flat plane, Single slope and Dual slope. Before you move the undercarriage, place the bucket tip on a point which can also be reached from the place you will be moving the undercarriage to. Press “OK” on the screen. Move the undercarriage and position the bucket tip on the same point. Press “OK” on the screen again. Graphical Settings By pressing Graphics you access a menu on which you can choose the appearance of the Digging Window in order to adapt it optimally to you and your needs at any time. P/N 7010-1020 3-9 Measurement Point of Bucket Here you can choose whether to use the middle of the bucket tip, or the left or right bucket tip as reference point. NOTICE The bucket measurement point is used everywhere in X-22 where you are asked to use the bucket tip. Visible Elements Here you can select which elements are to be shown in the Digging Window. Brightness of Digging Window X-22 has a so-called transreflective screen to give you the best possible picture when sunlight is directly on the screen. If it is dark outside and you find the light from the screen too bright, you can dim it here. Note that it takes approx. 10 seconds to open the Digging Window while the screen is being dimmed. Angular Difference for Bucket Warning You can use this function if you have a tilting bucket and tilting sensor. In the window showing the bucket from the driver’s cab, the color of the bucket will change to show that the sideways angle of the bucket blade is too large, too small or correct for the project. Here you can enter how large an angular difference you will accept before the bucket changes colour. Working Area The size of the working area determines when the target ball will start to move and when the “Color warning” will be given. By increasing the size of the working area you make the target ball less sensitive. 3-10 X-22 User’s Manual X-22 Setup NOTICE If X-22 is correctly installed, it will measure to an accuracy of one centimeter on a normal excavator. The size of the working area will not affect measurement accuracy. Focus Here you can choose whether you want the excavator undercarriage to be stationary while you work or if you want the bucket to remain stationary while the rest of the excavator and the project move around. Color Warning Here you can select whether X-22 will give you a color warning when the measurement point on the bucket tip is above or below the indicated working area. You can choose between a color change on the background to the screen, to the whole excavator or just the bucket. Size of Excavator Here you can select how much space the excavator will take up on the screen by increasing or reducing its size. Position of Excavator Here you can move the excavator around the screen. Appearance of Excavator Here you can select how the excavator will look from the side. Change the appearance to a small machine if you have a small excavator with the boom fixed in front of the driver's cab. P/N 7010-1020 3-11 Sound Settings Sound signals can be a useful aid in addition to the screen display. Here you can decide whether you want a sound signal when the measurement point on the bucket tip is in or under the working area. The height alarm also has a sound signal. Height Alarm The height alarm will warn you if the top of the arm or bucket is over a certain height above the underside of the tracks. To turn the height alarm on, you need to enter two extra excavator dimensions and indicate the alarm height. NOTICE Note that the height alarm is indicated in relation to the underside of the excavator tracks and not in relation to the project. Using the Compass In order to make full use of X-22 when excavating sloping projects, it is essential that the compass gives an accurate measurement. It is therefore important that the compass is well calibrated. NOTICE Note that the compass is at its most accurate when the undercarriage is horizontal. However, sometimes the compass may not give an accurate reading even when the undercarriage is level. The greater the gradient/slope in the project, the greater the error in bucket height will be if the compass is measuring incorrectly. 3-12 X-22 User’s Manual X-22 Setup When excavating across large slopes you should therefore consider turning off the compass and keeping track of the direction yourself. You can turn off the compass by selecting Main menu Setup Hardware Sensors and marking the PitchRollCompass sensor. Select Details. Then select Compass on and press Change. Speed of Sensors Excavators may vibrate a great deal or very little, depending on rpm, size, age, make etc. and this will affect the sensors’ angular measurements. X-22 has been designed to ensure the sensors give the optimum in stable, quick and accurate angular measurements in all types of excavators. It is therefore possible to alter the sensitivity and damping of the sensors for the best possible match with your excavator. At the factory the sensors are set with the aim of being stable when the excavator is stationary, but reacting immediately when the machine moves. To make changes to this, select Main Menu Setup Hardware Sensors, and press Sensitivity. Sensitivity Sensitivity indicates how strong the vibrations in the excavator must be before X-22 interprets this as a movement of the machine. By increasing the sensitivity, smaller vibrations in the machine may be interpreted as a movement of the machine. Reducing the sensitivity means that it will take larger vibrations to be interpreted as a movement of the machine. P/N 7010-1020 3-13 Damping Damping indicates how much the angular measurements will be filtered when the excavator is stationary. Filtering makes the angular measurements stable and accurate despite vibrations. By increasing the damping, X-22 will react more slowly to small and limited movements in the machine. By reducing the damping, X-22 will react more quickly to small and limited movements in the machine. Damping is set high at the factory and can thus be probably adjusted downwards. 3-14 X-22 User’s Manual Chapter 4 Troubleshooting In this section you will find answers to the following questions: The X-22 Display is not responding, what should I do?......... page 4-1 The sensors are not responding, what should I do?................page 4-1 A sensor is damaged, what should I do?...............................page 4-1 How do I recalibrate a sensor?..............................................page 4-1 The system is not measuring accurately, what should I do?....page 4-2 The compass is measuring incorrectly, what should I do?......page 4-2 The laser sensor is not working, what should I do?...............page 4-2 The X-22 Display is not responding, what should I do? Most X-22 problems can be solved by turning the X-22 Display off and on. The sensors are not responding, what should I do? If you are having problems making contact with the sensors, proceed as follows: Turn the X-22 Display off and put all the sensors in the charger for a few minutes. The sensors will then be reset while they are being charged. Take all the sensors out of the charger and turn the X-22 Display back on. A sensor is damaged, what should I do? You can obtain a new sensor by contacting your dealer. Delete the damaged sensor from the X-22 Display before entering the new one. P/N 7010-1020 4-1 How do I recalibrate a sensor? If you have already calibrated the sensors and want to recalibrate one, proceed as follows: Select Main menu Setup Hardware Sensors and highlight the sensor you want to calibrate. Select Details. Then select Calibrated and press Change. The system is not measuring accurately, what should I do? If the system is not measuring accurately, a dimension or calibration value is probably wrong. Select Verify from the menu in the Digging Window, and press Troubleshooting. X-22 will then help you identify the problem and rectify it. Follow the on-screen instructions. The compass is measuring incorrectly, what should I do? The compass in the PitchRollCompass sensor is magnetic and has to be calibrated in order to measure correctly. Therefore try recalibrating the compass to see if this helps. Select Main Menu Setup Hardware Sensors PitchRollCompass Details. Then select Calibrated, and press Change. If you want to check how well the compass is calibrated, you can select Main MenuSetupHardwareSensors PitchRollCompassVerify. When the machine is stationary and the superstructure is rotated, the compass measurements should ideally form a perfect circle with the center at the origin. In certain special circumstances the magnetic compass can be disrupted so much that it should not be used. In this situation the heading on the screen can change even if the machine is at a complete standstill. If this happens, the compass should be turned off. Select Main menu Setup Hardware Sensors and highlight the PitchRollCompass sensor. Select “Details”. Then select “Compass 4-2 X-22 User’s Manual Troubleshooting on” and press “Change”. All the software functions that use the heading measurements from the compass will now disappear and you will have to keep track of the heading yourself. In situations where there are large fluctuations in the magnetic field around the machine all the time, the compass calibration will not be able to compensate for the disturbances. An example of such a situation is if the machine is close to a railway line that is in use: Trains are surrounded by a strong magnetic field, which will badly disrupt the compass measurements whenever a train goes past. In this case the heading displayed on the screen could change even if the machine is at a complete standstill. Working in the vicinity of high-voltage cables can also cause problems for the magnetic compass. The laser sensor is not working, what should I do? The laser sensor may have problems detecting the laser beam in strong sunlight, particularly if the sun is shining straight into the photoelectric cell. If this happens, the amount of sunlight hitting the cell will have to be reduced by turning the sensor away from the sun, for example. If the laser sensor is exposed to strobe lighting, a rotating flashing light or the like, the sensor may be misled into thinking that it has detected the laser. If the laser sensor does not respond to the laser beam at all, even at close range, the photoelectric cell has probably been damaged. In this case you will have to contact your dealer to have the sensor replaced. P/N 7010-1020 4-3 Notes: 4-4 X-22 User’s Manual Appendix A Specifications X-22 Sensor The following section provides specifications for the X-22 Sensor. Table A-1. X-22 Sensor General Specifications General Details Enclosure Xenoy CL 100 Polycarbonate Resistant to hydraulic fluids, diesel and UV exposure IP67 Color Topcon Yellow Dimensions W: 112 mm x H: 48 mm x D: 68 mm W: 4.4 in. x H: 1.89 in. x D: 2.68 in. Weight 230g (standard sensor) 0.5 lbs. Battery Operating time: Up to four weeks with normal use Material: Lithium-ion polymer Nominal capacity: 5600mAh Charging time: Overnight Expected battery life: Beyond 3 years Operating temperature -20°C to +60°C -4°F to +140°F Charging temperature +5°C to +35°C -41°F to +95°F Storage temperature -20°C to +35°C -4°F to +95°F Radio Range: Over 50m (164 ft) line-of-sight Frequency: 2.4 GHz license-free ISM-band Proprietary packet radio protocol P/N 7010-1020 A-1 Table A-1. X-22 Sensor General Specifications (Continued) Connectors 2 charging pins (6V DC input, no polarity) X-22 Display The following section provides specifications for the X-22 Fanless 8.9” WSVGA TFT Multifunctional Touch Panel PC. Table A-2. X-22 Sensor General Specifications Display Screen LCD Size 8.9” Display Type WSVGA TFT Resolution 1024 x 600 Color 256K Pixel Pitch 0.1905mm (H) x 0.189mm (V) Luminance 220cd/m² Contrast Ratio 500 Viewing Angle 50 (U), 60 (D), 70 (L), 70 (R) Response Time 30ms Backlight LED Touch Screen 5-Wire Resistive Light transmission 80% Touch Interface USB Onboard Touch Interface System CPU Onboard AMD Geode LX800 @ 0.9W 500MHz with 128K L2 Cache CPU Cooling Method Passive CPU Heatsink System Chipset AMD Geode LX800/ CS5536 A-2 X-22 User’s Manual Table A-2. X-22 Sensor General Specifications (Continued) System Memory Onboard 512MB DDR Memory SSD One CF Socket by IDE Secondary Slave Channel Supports Type I/II Compact Flash Card Rear Panel I/O Serial Port 1 x RS-232, 1 x RS-232 or Optional RS-422/ 485 Ethernet 2 x RJ-45 (Realtek RTL8101L LAN) WIFI Optional USB WiFi 802.11 b/g (Occupies One USB Port) VGA 1 x DB-15 Audio Line-out, Mic-in USB 2 x USB 2.0 Mouse & K/B 1 x PS/2 Keyboard Connector Environment & Mechanical Color Front Panel Black; Rear Panel Black Mounting Wall/ Stand/ VESA 75mm x 75mm Power Input 100 ~ 250Vdc/ 47 ~ 63Hz Power Output +12Vdc/ 5A (60W) Operating Temperature -10°C ~ 60°C 14°F to +140°F Storage Temperature -20°C ~ 70°C -4°F to +158°F Relative Humidity 10% to 95% @ 40°C, Non-condensing Dimension W: 225mm x H: 139mm x D: 38.9mm W: 8.86 in. x H: 5.47 in. x D: 1.53 in. Weight 1.26Kgs (2.78 lbs.) P/N 7010-1020 A-3 A-4 X-22 User’s Manual Appendix B Safety Warnings General Warnings 1. Read and become familiar with the machine manufacturer’s operating instructions, including safety information, before installing or using your Topcon equipment. 2. Use extreme caution on the jobsite. Working around heavy construction equipment can be dangerous. 3. DO NOT attach system brackets while the machine is running. 4. DO NOT allow any X-22 system component to limit the visibility of the operator. 5. Use Ty-wraps, to keep hoses and wires secured and away from possible wear or pinch points. 6. Use eye protection whenever welding, cutting, or grinding is being done on the machine. 7. Protect yourself at all times, and wear protective clothing, when working on or near hydraulic lines. Avoid direct exposure to your eyes when using laser control. CAUTION DO NOT stare into the laser beam or view the beam directly with optical equipment. 8. Use appropriate welding precautions and practices when welding. After welding, all paint all affected areas with a rust inhibitor. WARNING P/N 7010-1020 DO NOT weld near hydraulic lines or on any equipment when in operation. B-1 NOTICE NOTICE Disconnect all Topcon system electrical cables prior to welding on the machine. All mounting bracket welds must be secure and strong to prevent sensor equipment from vibrating excessively or from becoming detached at the weld during operation. 9. To prevent vandalism or theft, do not leave removable Topcon components on the machine at night. Remove the components each evening and store appropriately in the carrying case. 10. Keep the carrying case dry at all times. NOTICE DO NOT allow moisture to get inside the case. Moisture trapped in the case can adversely affect components. If moisture does enter the carrying case, leave it open and allow it to thoroughly dry before storing any components. B-2 X-22 User’s Manual Sensor Warnings DANGER DANGER WARNING Never attempt to open the X-22 sensors! LithiumIon batteries can be dangerous if mishandled! Do not incinerate or heat battery pack above 212 degrees fahrenheit (100 degrees celsius). Excessive heat can cause serious damage and possible explosion. Tampering with the batteries by end users or nonfactory authorized technicians will void the battery’s warranty. • Do not attempt to open the sensors. • Do not disassemble the sensor. • Do not charge in conditions different than specified. • Do not use other than the specified battery charger. • Do not short circuit. • Do not crush or modify. P/N 7010-1020 B-3 Usage Warnings CAUTION CAUTION B-4 If this product has been dropped, altered, transported or shipped without proper packaging, or otherwise treated without care, erroneous measurements may occur. The owner should periodically test this product to ensure it provides accurate measurements. Inform Topcon immediately if this product does not function properly. Only allow authorized Topcon warranty service centers to service or repair this product. X-22 User’s Manual Appendix C Regulatory Information The following sections provide information on this product’s compliance with government regulations for use. FCC Compliance This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television equipment reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Move the equipment away from the receiver. • Plug the equipment into an outlet on a circuit different from that to which the receiver is powered. • Consult the dealer or an experienced radio/television technician for additional suggestions. P/N 7010-1020 C-1 CAUTION Any changes or modifications to the equipment not expressly approved by the party responsible for compliance could void your authority to operate such equipment. FCC Compliance This equipment complies with FCC radiation exposure limits set forth for uncontrolled equipment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE). But it is desirable that it should be installed and operated with at least 20cm and more between the radiator and person’s body (excluding extremities: hands, wrists, feet and ankles). This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television equipment reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Move the equipment away from the receiver. C-2 X-22 User’s Manual • Plug the equipment into an outlet on a circuit different from that to which the receiver is powered. • Consult the dealer or an experienced radio/television technician for additional suggestions. CAUTION Any changes or modifications to the equipment not expressly approved by the party responsible for compliance could void your authority to operate such equipment. Federal Communication Commission Declaration of Conformity (DoC) Statement Model No: HiPer II Trade Name Topcon Responsible Party Topcon Positioning Systems, Inc. Address 7400 National Drive, Livermore, CA 94550 Telephone No +925-245-8300 P/N 7010-1020 C-3 Canadian Emission Labeling Requirements This equipment complies with IC radiation exposure limits set forth for uncontrolled equipment and meets RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE). But it is desirable that it should be installed and operated with at least 20cm and more between the radiator and person’s body (excluding extremities: hands, wrists, feet and ankles). 1. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. 2. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. 3. This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte conform a la norme NMB-003 du Canada. IC RF Radiation Exposure Statement This installer of this device must ensure that the antenna is located or pointed such that it dose not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website at www.hc-sc.gc.ca/rpb. C-4 X-22 User’s Manual Community of Europe Compliance The product described in this manual is in compliance with the R&TTE and EMC directives from the European Community. European Community Declaration of Conformity with R&TTE Directive 1999/5/EC The following standards were applied: (R&TTE Directive 1999/5/EEC) • • • • EN 301 489-1 V1.8.1 (2008-04) EN 301 489-17 V1.3.2 (2008-04) EN 300 328 V1.7.1 (2006-10) EN 60950-1:2001 + A11:2004 The following CE mark is affixed to the device: P/N 7010-1020 C-5 Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC cs esky [Czech] da Dansk [Danish] de Deutsch [German] et Eesti [Estonian] (Topcon) tímto prohlašuje, že tento (HiPer II) je ve shod se základními požadavky a dalšími píslušnými ustanoveními smrnice 1999/5/ES. Undertegnede (Topcon) erklærer herved, at følgende udstyr (HiPer II) overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Hiermit erklärt (Topcon) dass sich das Gerät (HiPer II) in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Käesolevaga kinnitab (Topcon) seadme (HiPer II) vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. en English Hereby, (Topcon) declares that this (HiPer II) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. es Español Por medio de la presente (Topcon) declara que el (HiPer II) cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. [Spanish] el [Greek] fr Français [French] C-6 Par la présente (Topcon) déclare que l'appareil (HiPer II) est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. X-22 User’s Manual it Italiano [Italian] la Latviski [Latvian] Con la presente (Topcon) dichiara che questo (HiPer II) è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Ar šo (Topcon) deklar, ka (HiPer II) atbilst Direktvas 1999/5/EK btiskajm prasbm un citiem ar to saisttajiem noteikumiem. Lietuvi [Lithuanian] Šiuo (Topcon) deklaruoja, kad šis (HiPer II) atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Nederlan ds [Dutch] Hierbij verklaart (Topcon) dat het toestel (HiPer II) in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/ 5/EG. Malti Hawnhekk, (Topcon) , jiddikjara li dan (HiPer II) jikkonforma mal-tiijiet essenzjali u ma provvedimenti orajn relevanti li hemm fid-Dirrettiva 1999/5/EC. li nl mt [Maltese] hu Magyar [Hungarian] pl Polski [Polish] pt Portuguê [Portugues] sl Slovensk [Slovenian] da Slovensy [Slovak] P/N 7010-1020 Alulírott, (Topcon) nyilatkozom, hogy a (HiPer II) megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Niniejszym, (Topcon) , deklaruj, e (HiPer II) spenia wymagania zasadnicze oraz stosowne postanowienia zawarte Dyrektywie 1999/5/EC. (Topcon) declara que este (HiPer II) está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. (Topcon) izjavlja, da je ta (HiPer II) v skladu z bistvenimi zahtevami in ostalimi relevantnimi doloili direktive 1999/5/ES. (Topcon) týmto vyhlasuje, že (HiPer II) spa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. C-7 fi Suomi [Finnish] sv Svenska [Swedish] (Topcon) vakuuttaa täten että (HiPer II) tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Härmed intygar (Topcon) att denna (HiPer II) står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. WEEE Directive Following information is for EU-member states only: The use of the symbol below indicates that this product may not be treated as household waste. By ensuring this product is disposed of correctly, to help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about the take-back and recycling of this product, please contact a supplier where you purchased the product or consult. C-8 X-22 User’s Manual Appendix D Warranty Terms TPS laser and electronic positioning equipment are guaranteed against defective material and workmanship under normal use and application consistent with this Manual. The equipment is guaranteed for the period indicated, on the warranty card accompanying the product, starting from the date that the product is sold to the original purchaser by TPS’ Authorized Dealers.1 During the warranty period, TPS will, at its option, repair or replace this product at no additional charge. Repair parts and replacement products will be furnished on an exchange basis and will be either reconditioned or new. This limited warranty does not include service to repair damage to the product resulting from an accident, disaster, misuses, abuse or modification of the product. Warranty service may be obtained from an authorized TPS warranty service dealer. If this product is delivered by mail, purchaser agrees to insure the product or assume the risk of loss or damage in transit, to prepay shipping charges to the warranty service location and to use the original shipping container or equivalent. A letter should accompany the package furnishing a description of the problem and/ or defect. The purchaser’s sole remedy shall be replacement as provided above. In no event shall TPS be liable for any damages or other claim including any claim for lost profits, lost savings or other incidental or consequential damages arising out of the use of, or inability to use, the product. 1. The warranty against defects in a Topcon battery, charger, or cable is 90 days. P/N 7010-1020 D-1 Notes: D-2 X-22 User’s Manual Topcon Positioning Systems, Inc. 7400 National Drive, Livermore, CA 94550 800∙443∙4567 www.topconpositioning.com ISO 9001:2000 FM 68448 X-22 User’s Manual P/N: 7010-1020 Rev A 06/11 ©2011 Topcon Positioning Systems, Inc. All rights reserved. No unauthorized duplication.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Creator Tool : FrameMaker 7.1 Modify Date : 2011:06:13 14:00:54-07:00 Create Date : 2011:06:09 09:48:55Z Metadata Date : 2011:06:13 14:00:54-07:00 Format : application/pdf Title : X-22 User's Manual Creator : Topcon Producer : Acrobat Distiller 8.2.6 (Windows) Document ID : uuid:da6a447b-2494-4327-a74d-d4406a95c348 Instance ID : uuid:81f07c03-2503-440c-805d-82bad4d185ce Has XFA : No Page Count : 72 Page Layout : SinglePage Author : TopconEXIF Metadata provided by EXIF.tools