Topcon RD-10W Remote Display User Manual RD 10W E

Topcon Corporation Remote Display RD 10W E

Users Manual

INSTRUCTION MANUALREMOTE DISPLAYRD-10WThank you for purchasing the TOPCON RD-10W.For the best performance of the instruments, please read these instructionscarefully and keep them in a convenient location for future reference.DISPLAY FOR SAFE USEIn order to encourage the safe use of products and prevent any danger tothe operator and others or damage to properties, important warnings areput on the products and inserted in the instruction manuals.We suggest that everyone understand the meaning of the following displaysand icons before reading the “Safety Cautions” and text.• Injury refers to hurt, burn, electric shock, etc.•Physical damage refers to extensive damage to buildings or equipment and furniture.HANDLING PRECAUTIONSGuarding the instrument against shockWhen transporting the instrument, provide some protection to minimize riskof shock.  Heavy shock may affect beam accuracy.SAFETY CAUTIONSStandard Set Composition1 RD-10W Instrument................................................. 1pc.2 AA-size dry cells...................................................... 3pcs.3Instruction manual ................................................... 1pc.Display MeaningWARNING Ignoring or disregard of this display may lead to death or serious injury.CAUTION Ignoring or disregard of this display may lead to per-sonal injury or physical damage to the instrument.WARNING• There is a risk of fire, electric shock or physical harm if you attempt to disassemble or repair the instrument yourself.This is only to be carried out by TOPCON or an authorized dealer, only!• Risk of fire or electric shock  Do not use damaged power cable, plug and socket. • Risk of fire or electric shock. Do not use a wet battery. • May ignite explosively. Never use an instrument near flammable gas, liquid matter, and do not use in a coal mine. • Do not hold the RD-10W magnetic clamp near anyone who uses a pace maker or other electoronic medical devices. The strong magnetic field can disrupt the normal operation of such devices. • Battery can cause explosion or injury. Do not dispose in fire or heat. • The short circuit of a battery can cause a fire. Do not short circuit battery when storing it. CAUTION Risk of injury to fingers.Do not place fingers on magnet while mounting to equipment.Strong  magnetic field.Do not place RD-10W magnetic clamp near  any sensitive electronic devices or magnetic storage media such as computer disk.Do not allow skin or clothing to come into contact with acid from the batteries, if this does occur then wash off with copious amounts of water and seek med-ical advice.EXCEPTIONS  FROM  RESPONSIBILITY1)The user of this product is expected to follow all operating instructions and make periodic checks of the product’s performance.2)The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits.3)The manufacturer, or its representatives, assumes no responsibility for consequential damage,and loss of profits by any disaster, (an earthquake, storms, floods etc.).A fire, accident, or an act of a third party and/or a usage any other usual conditions.4)The manufacturer, or its representatives, assumes no responsibility for any damage,and loss of profits due to a change of data, loss of data, an interruption of business etc., caused by using the product or an unusable product.5)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage except for explained in the user manual.6)The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement, or action due to connecting with other products.
 Nomenclature and FunctionsHow to set up the wireless communication default setting Place the LS-B10W and RD-10W in close position, so that they will not be affected by other wireless communications. 1 Tu rn on the power for both the LS-B10W and RD-10W. 2 Long-push the wireless communication switch for the LS-B10W and RD-10W. When setting up, the instrument will be in the communication set-up status, and the LED (yellow light) will flash slowly. 3 When the instrument is ready to be used, a buzzer will sound (buzzer sound: peep) and the communication will begin. During communication, the LED will flash quickly. How to use wireless communication 1 When power for both the LS-B10W and RD-10W are turned ON, communication will automatically begin.•If the communication fails, a buzzer will sound (buzzer sound: pi, pi, pi) and the LED will turn off. Eliminate any influence from other wireless instrument and redo the communication default setting.•While setting up the default, only the default OFF (short-push of the wireless communication switch) is operable.•When beginning the communication, detective precision, buzzer sound, LED ON/OFF setting will be changed to the same setting as the LS-B10W.•When changing the setting for detective precision, buzzer sound and LED ON/OFF, the setting for the LS-B10W will also change in conjunction with the RD-10W.•If you wish to change the LS-B10W to communicate, redo the communication default setting.•If the LED continues to flash, a communication error is occurring. If flashing continues after turning off the power and on once again, please inquire with your sales agent.Battery cover knobBattery coverMagnetIndexIndicator(LCD)Power switchPower ON: Short pushPower OFF: Long pushLCD back light ON/OFF: Short push when power is ON (Auto turn-off after two minutes)Detective precision (Mode) switchBuzzer sound switchBuzzer sound: Quiet/Loud/OFF: Short pushLED ON/OFF: Long pushIndicator(LED)Buzzer speaker•See [Laser beam positions and display patterns] in the Instruction manual for the display area and dis-play pattern.• This instrument is able to perform wireless communication with the LS-B10W, sold separately.See the LS-B10W Instruction manual for details on the LS-B10W.Wireless communication switchCommunication ON/OFF: Short push
 Indicator Height alert warning of rotating laser A flash and a buzzer sound signifies that the height alert function of rotating laser is operating.(This function is not usable to the rotat-ing laser which does not have the height alert and the function to output alarm signal.) Rotating laser battery warning A flash shows that the rotating laser power is low.(This function is not usable to the rotating laser which does not have the function to output alarm signal.) Higher than datum position Move the sensor downward.(Buzzer sound:High frequent beep sound) Datum position (ON GRADE position) (Buzzer sound:Continuous beep sound) Lower than datum position Move the sensor upward.(Buzzer sound:Low frequent beep sound) Battery remaining display Indicates the battery remaining of remote display as follows. Flashing alternately Battery is sufficient.The power is low, but remote display is still usable.Dead battery. Replace the dry battery with new one.Mode1Mode2Mode3Mode4 (Blinking) Precision mode Indicator(LED)Flashes slowly Power-save function The power-save function will activate in conjunction with the LS-B10W power-save function.In the power-save mode, the indicator LCD turns off and one indicator LED blinks green.(The mode is canceled automatically when the power-save mode for the LS-B10W is canceled.The mode can also be canceled by pressing the power switch again.) Auto-cut off function The power will be turned off automatically in conjunction with the LS-B10W auto-cut off function.(To turn on the power, press the power switch for both the LS-B10W and the RD-10W.)Mode1:±2mmMode2:±6mmMode3:±12mmMode4:±30mm±15mm/±0.05ft(30mm/0.1ft width)When the laser beam is off to the top or to the bottomWireless communication range:20m(May vary depending on obstacles between the two instruments and other conditions)Power source : AA-size dry cells   3pcs. Continuous operating time(+20°C/+68°F):Approximately 40 hours(Using alkaline manganese dry cells)Operating temperature : -20°C~+50°C(-4°F~+122°F)Water proof : IP66Dimensions (W/D/H) : 110x36x176(mm) (4.3″x1.4″x6.9″)Weight (Without cells) : 0.5kg (1.2lbs)Detective angle, Detective precision and Laser detecting range may vary depending on rotating laser  being used or atmospheric conditions.No display when in Mode 4No display when in Mode 4Flashes slowlyLaser beam positions and display patterns SpecificationsIndicator(LCD) Indicator(LED)±25mm/±0.08ft(50mm/0.16ft width)±35mm/±0.11ft(70mm/0.23ft width)±60mm/±0.2ft(120mm/0.39ft width)Detective precisionFlashes quicklyFlashes more slowly
TOPCON CORPORATION75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan  Phone: 3-3558-2520  Fax: 3-3960-4214   www.topcon.co.jpTOPCON POSITIONING SYSTEMS, INC.7400 National Drive, Livermore, CA 94551, U.S.A.Phone: 925-245-8300 Fax: 925-245-8599 www.topcon.comTOPCON CALIFORNIA3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.Phone: 916-374-8575 Fax: 916-374-8329TOPCON EUROPE POSITIONING B.V.Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.Phone: 010-458-5077 Fax: 010-284-4949 www.topconeurope.com TOPCON DEUTSCHLAND G.m.b.H.Giesserallee 31, 47877 Willich, GERMANYPhone: 02154-885-100 Fax: 02154-885-111  info@topcon.dewww.topcon.deTOPCON S.A.R.L. 89, Rue de Paris, 92585 Clichy, Cedex, France.Phone: 33-1-41069490  Fax: 33-1-47390251  topcon@topcon.fr TOPCON ESPAÑA S.A.Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern, Barcelona, Spain.Phone: 93-473-4057 Fax: 93-473-3932  www.topconesp.comTOPCON SCANDINAVIA A. B. Neongatan 2 S-43151 Mölndal, SWEDENPhone: 031-7109200 Fax: 031-7109249TOPCON (GREAT BRITAIN)LTD.Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.Phone: 44-1635-551120 Fax: 44-1635-551170survey.sales@topcon.co.uk   laser.sales@topcon.co.ukTOPCON SOUTH ASIA PTE. LTD.Blk 192 Pandan Loop, #07-01 Pantech Industrial Complex, Singapore 128381Phone: 62780222 Fax: 62733540  www.topcon.com.sgTOPCON AUSTRALIA PTY. LTD.Unit 18, 4 Avenue of Americas Newington NSW 2127, AustraliaPhone: 02-8748-8777 Fax: 02-9647-2926  www.topcon.com.auTOPCON INSTRUMENTS (THAILAND) CO., LTD.77/162 Sinn Sathorn Tower, 37th Fl.,Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.Phone: 02-440-1152~7  Fax: 02-440-1158TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.Excella Business Park Block C, Ground & 1st Floor,   Jalan Ampang Putra, Taman Ampang Hilir, 55100 Kuala Lumpur, MALAYSIA  Phone: 03-42701068  Fax: 03-42704508TOPCON KOREA CORPORATION2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea.Phone: 82-2-2055-0321 Fax: 82-2-2055-0319  www.topcon.co.krTOPCON OPTICAL (H.K.) LIMITED2-4/F Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road, Shatin, N.T., Hong KongPhone: 2690-1328  Fax: 2690-2221  www.topcon.com.hkTOPCON CORPORATION BEIJING OFFICEBuilding A No.9, Kangding StreetBeijing Economic Technological Development Area, Beijing, China 100176Phone: 10-6780-2799  Fax: 10-6780-2790TOPCON CORPORATION BEIRUT OFFICEP. O. BOX 70-1002 Antelias, BEIRUT-LEBANON. Phone: 961-4-523525/961-4-523526  Fax: 961-4-521119 TOPCON CORPORATION DUBAI OFFICEC/O Atlas Medical FZCO., P. O. Box 54304, C-25, Dubai Airport Free Zone,UAEPhone: 971-4-2995900 Fax: 971-4-2995901 IRELAND OFFICEUnit 69 Western Parkway Business CenterPhone: 01460-0021 Fax: 01460-0129Lower Ballymount Road, Dublin 12, Lreland1A    Declaration of Confomity    R&TTE Directive  1995/5/ECWE:   TOPCON CORPORATION    75-1 Hasunuma-cho Itabashi-ku Tokyo Japan   declare on our own responsibility, that the product;Kind of Product: Remote DisplayType designation: RD-10Wis in compliance with the following norm(s) or documents;Radio  :EN 300 328EMC    :EN 301 489-1/17safety  :EN 60950 RD-10W   31266  90061 Changes or modifications not expressly approved by the manufacturer for compliance could void the user’s authority to operate theequipment.In order to comply with FCC radio-frequency radiation exposure guidelines for an uncontrolled exposure, this device and its antennamust not be co-located or operating in conjunction with any other antenna or transmitter.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may notcause harmful interference, and (2) this device must accept any interference received, including interference that may cause undes-ired operation."Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this devicemust accept any interference, including interference that may cause undesired operation of the device."

Navigation menu