Topcon RD-10W Remote Display User Manual RD 10W E

Topcon Corporation Remote Display RD 10W E

Users Manual

Download: Topcon RD-10W Remote Display User Manual RD 10W E
Mirror Download [FCC.gov]Topcon RD-10W Remote Display User Manual RD 10W E
Document ID686132
Application IDQEq01m1ssAlVZVpTkkCxJA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize117.48kB (1468489 bits)
Date Submitted2006-07-25 00:00:00
Date Available2006-07-25 00:00:00
Creation Date1904-01-01 22:04:32
Producing SoftwareAcrobat Distiller 5.0.1 for Macintosh
Document Lastmod2006-07-13 18:25:58
Document TitleRD-10W(E).fm
Document CreatorFrameMaker 6.0
Document Author: sakurai_mac

Standard Set Composition
INSTRUCTION MANUAL
REMOTE DISPLAY
RD-10W
Thank you for purchasing the TOPCON RD-10W.
For the best performance of the instruments, please read these instructions
carefully and keep them in a convenient location for future reference.
DISPLAY FOR SAFE USE
In order to encourage the safe use of products and prevent any danger to
the operator and others or damage to properties, important warnings are
put on the products and inserted in the instruction manuals.
We suggest that everyone understand the meaning of the following displays
and icons before reading the “Safety Cautions” and text.
Display
Meaning
WARNING
Ignoring or disregard of this display may lead to
death or serious injury.
CAUTION
Ignoring or disregard of this display may lead to personal injury or physical damage to the instrument.
• Injury refers to hurt, burn, electric shock, etc.
• Physical damage refers to extensive damage to buildings or equipment
and furniture.
HANDLING PRECAUTIONS
Guarding the instrument against shock
When transporting the instrument, provide some protection to minimize risk
of shock. Heavy shock may affect beam accuracy.
SAFETY CAUTIONS
WARNING
• There is a risk of fire, electric shock or physical harm if you attempt to
disassemble or repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer, only!
• Risk of fire or electric shock
Do not use damaged power cable, plug and socket.
• Risk of fire or electric shock.
Do not use a wet battery.
• May ignite explosively.
Never use an instrument near flammable gas, liquid matter, and do not use in
a coal mine.
• Do not hold the RD-10W magnetic clamp near anyone who uses a pace
maker or other electoronic medical devices.
The strong magnetic field can disrupt the normal operation of such devices.
• Battery can cause explosion or injury.
Do not dispose in fire or heat.
• The short circuit of a battery can cause a fire.
Do not short circuit battery when storing it.
CAUTION
Risk of injury to fingers.
Do not place fingers on magnet while mounting to equipment.
Strong magnetic field.
Do not place RD-10W magnetic clamp near any sensitive electronic devices
or magnetic storage media such as computer disk.
Do not allow skin or clothing to come into contact with acid from the batteries,
if this does occur then wash off with copious amounts of water and seek medical advice.
EXCEPTIONS FROM RESPONSIBILITY
1)The user of this product is expected to follow all operating instructions and make
periodic checks of the product’s performance.
2)The manufacturer, or its representatives, assumes no responsibility for results of a
faulty or intentional usage or misuse including any direct, indirect, consequential
damage, and loss of profits.
3)The manufacturer, or its representatives, assumes no responsibility for
consequential damage,and loss of profits by any disaster, (an earthquake, storms,
floods etc.).
A fire, accident, or an act of a third party and/or a usage any other usual conditions.
4)The manufacturer, or its representatives, assumes no responsibility for any
damage,and loss of profits due to a change of data, loss of data, an interruption of
business etc., caused by using the product or an unusable product.
5)The manufacturer, or its representatives, assumes no responsibility for any
damage, and loss of profits caused by usage except for explained in the user
manual.
6)The manufacturer, or its representatives, assumes no responsibility for damage
caused by wrong movement, or action due to connecting with other products.
1 RD-10W Instrument................................................. 1pc.
2 AA-size dry cells...................................................... 3pcs.
3 Instruction manual ................................................... 1pc.
Nomenclature and Functions
Wireless communication switch
Communication ON/OFF: Short push
Power switch
Power ON: Short push
Power OFF: Long push
LCD back light ON/OFF: Short push when
power is ON
(Auto turn-off after two minutes)
Magnet
Index
Detective precision (Mode) switch
Battery cover
Buzzer sound switch
Buzzer sound: Quiet/Loud/OFF: Short push
LED ON/OFF: Long push
Indicator(LCD)
Battery cover knob
Indicator(LED)
Buzzer speaker
• See [Laser beam positions and display patterns] in the Instruction manual for the display area and display pattern.
• This instrument is able to perform wireless communication with the LS-B10W, sold separately.
See the LS-B10W Instruction manual for details on the LS-B10W.
How to set up the wireless communication default setting
Place the LS-B10W and RD-10W in close position, so that they will not be affected by other wireless communications.
1 Turn on the power for both the LS-B10W and RD-10W.
2 Long-push the wireless communication switch for the LS-B10W and RD-10W. When setting up, the instrument will be in the communication set-up
status, and the LED (yellow light) will flash slowly.
3 When the instrument is ready to be used, a buzzer will sound (buzzer sound: peep) and the communication will begin. During communication, the
LED will flash quickly.
• If the communication fails, a buzzer will sound (buzzer sound: pi, pi, pi) and the LED will turn off. Eliminate any influence from other
wireless instrument and redo the communication default setting.
• While setting up the default, only the default OFF (short-push of the wireless communication switch) is operable.
How to use wireless communication
1 When power for both the LS-B10W and RD-10W are turned ON, communication will automatically begin.
• When beginning the communication, detective precision, buzzer sound, LED ON/OFF setting will be changed to the same setting as the
LS-B10W.
• When changing the setting for detective precision, buzzer sound and LED ON/OFF, the setting for the LS-B10W will also change in
conjunction with the RD-10W.
• If you wish to change the LS-B10W to communicate, redo the communication default setting.
• If the LED continues to flash, a communication error is occurring. If flashing continues after turning off the power and on once again,
please inquire with your sales agent.
Indicator
Precision mode
Height alert warning of
rotating laser
Mode1
A flash and a buzzer sound signifies
that the height alert function of rotating
laser is operating.
(This function is not usable to the rotating laser which does not have the height
alert and the function to output alarm
signal.)
Higher than datum position
Move the sensor downward.
(Buzzer sound:High frequent beep sound)
Mode2
Datum position (ON GRADE position)
(Buzzer sound:Continuous beep sound)
Mode3
Mode4 (Blinking)
Lower than datum position
Move the sensor upward.
(Buzzer sound:Low frequent beep sound)
Battery remaining display
Indicator(LED)
Flashes slowly
Indicates the battery remaining of remote display as follows.
Battery is sufficient.
Flashing alternately
Dead battery.
Replace the dry battery with new one.
Rotating laser battery warning
A flash shows that the rotating laser power
is low.
(This function is not usable to the rotating
laser which does not have the function to
output alarm signal.)
The power is low, but remote display is still usable.
Power-save function
The power-save function will activate in conjunction with the LS-B10W power-save function.
In the power-save mode, the indicator LCD turns off and one indicator LED blinks green.
(The mode is canceled automatically when the power-save mode for the LS-B10W is canceled.
The mode can also be canceled by pressing the power switch again.)
Auto-cut off function
The power will be turned off automatically in conjunction with the LS-B10W auto-cut off function.
(To turn on the power, press the power switch for both the LS-B10W and the RD-10W.)
Laser beam positions and display patterns
Indicator(LCD)
Indicator(LED)
Detective
precision
Mode1:±2mm
Mode2:±6mm
Mode3:±12mm
Mode4:±30mm
±15mm/±0.05ft
(30mm/0.1ft width)
Specifications
Wireless communication
range
20m
(May vary depending on obstacles between
the two instruments and other conditions)
Power source
AA-size dry cells 3pcs.
Continuous operating time
(+20°C/+68°F)
Approximately 40 hours
(Using alkaline manganese dry cells)
Operating temperature
-20°C~+50°C(-4°F~+122°F)
Water proof
IP66
Dimensions (W/D/H)
110x36x176(mm) (4.3″x1.4″x6.9″)
Weight (Without cells)
0.5kg (1.2lbs)
Detective angle, Detective precision and Laser detecting range may vary
depending on rotating laser being used or atmospheric conditions.
No display when in Mode 4
±25mm/±0.08ft
(50mm/0.16ft width)
No display when in Mode 4
Flashes quickly
±35mm/±0.11ft
(70mm/0.23ft width)
±60mm/±0.2ft
(120mm/0.39ft width)
Flashes slowly
When the laser
beam is off to
the top or to the
bottom
Flashes more slowly
Changes or modifications not expressly approved by the manufacturer for compliance could void the user’s authority to operate the
equipment.
In order to comply with FCC radio-frequency radiation exposure guidelines for an uncontrolled exposure, this device and its antenna
must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
"Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the device."
Declaration of Confomity
R&TTE Directive 1995/5/EC
WE:
TOPCON CORPORATION
75-1 Hasunuma-cho Itabashi-ku Tokyo Japan
declare on our own responsibility, that the product;
Kind of Product: Remote Display
Type designation: RD-10W
is in compliance with the following norm(s) or documents;
Radio :EN 300 328
EMC :EN 301 489-1/17
safety :EN 60950
TOPCON POSITIONING SYSTEMS, INC.
7400 National Drive, Livermore, CA 94551, U.S.A.
Phone: 925-245-8300 Fax: 925-245-8599 www.topcon.com
TOPCON CALIFORNIA
3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329
TOPCON SOUTH ASIA PTE. LTD.
Blk 192 Pandan Loop, #07-01 Pantech Industrial Complex, Singapore 128381
Phone: 62780222 Fax: 62733540 www.topcon.com.sg
TOPCON AUSTRALIA PTY. LTD.
Unit 18, 4 Avenue of Americas Newington NSW 2127, Australia
Phone: 02-8748-8777 Fax: 02-9647-2926 www.topcon.com.au
TOPCON INSTRUMENTS (THAILAND) CO., LTD.
TOPCON EUROPE POSITIONING B.V.
Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.
Phone: 010-458-5077 Fax: 010-284-4949 www.topconeurope.com
IRELAND OFFICE
Unit 69 Western Parkway Business Center
Lower Ballymount Road, Dublin 12, Lreland
Phone: 01460-0021 Fax: 01460-0129
77/162 Sinn Sathorn Tower, 37th Fl.,
Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.
Phone: 02-440-1152~7 Fax: 02-440-1158
TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.
TOPCON DEUTSCHLAND G.m.b.H.
Giesserallee 31, 47877 Willich, GERMANY
Phone: 02154-885-100 Fax: 02154-885-111 info@topcon.de
www.topcon.de
TOPCON S.A.R.L.
89, Rue de Paris, 92585 Clichy, Cedex, France.
Phone: 33-1-41069490 Fax: 33-1-47390251 topcon@topcon.fr
Excella Business Park Block C, Ground & 1st Floor, Jalan Ampang Putra,
Taman Ampang Hilir, 55100 Kuala Lumpur, MALAYSIA
Phone: 03-42701068 Fax: 03-42704508
TOPCON KOREA CORPORATION
2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea.
Phone: 82-2-2055-0321 Fax: 82-2-2055-0319 www.topcon.co.kr
TOPCON OPTICAL (H.K.) LIMITED
2-4/F Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road,
Shatin, N.T., Hong Kong
Phone: 2690-1328 Fax: 2690-2221 www.topcon.com.hk
Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern, Barcelona, Spain. TOPCON CORPORATION BEIJING OFFICE
Phone: 93-473-4057 Fax: 93-473-3932 www.topconesp.com
Building A No.9, Kangding Street
TOPCON ESPAÑA S.A.
TOPCON SCANDINAVIA A. B.
Beijing Economic Technological Development Area, Beijing, China 100176
Phone: 10-6780-2799 Fax: 10-6780-2790
Neongatan 2 S-43151 Mölndal, SWEDEN
Phone: 031-7109200 Fax: 031-7109249
TOPCON CORPORATION BEIRUT OFFICE
TOPCON (GREAT BRITAIN)LTD.
Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.
Phone: 44-1635-551120 Fax: 44-1635-551170
survey.sales@topcon.co.uk laser.sales@topcon.co.uk
P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON.
Phone: 961-4-523525/961-4-523526 Fax: 961-4-521119
TOPCON CORPORATION DUBAI OFFICE
C/O Atlas Medical FZCO., P. O. Box 54304, C-25, Dubai Airport Free Zone,UAE
Phone: 971-4-2995900 Fax: 971-4-2995901
TOPCON CORPORATION
75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
Phone: 3-3558-2520 Fax: 3-3960-4214 www.topcon.co.jp
RD-10W 31266 90061
1A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 5.0.1 for Macintosh
Create Date                     : 1904:01:01 22:04:32Z
Modify Date                     : 2006:07:13 18:25:58+08:00
Metadata Date                   : 2006:07:13 18:25:58+08:00
Creator Tool                    : FrameMaker 6.0
Format                          : application/pdf
Creator                         : sakurai_mac
Title                           : RD-10W(E).fm
Document ID                     : uuid:6709b68a-3d5e-4c01-bb97-25408749404d
Instance ID                     : uuid:84234d73-c2de-4a90-8f6f-e95e8bd6d4ad
Page Count                      : 4
Author                          : sakurai_mac
EXIF Metadata provided by EXIF.tools
FCC ID Filing: H5P-RD-10W

Navigation menu