Toro Greenkeeper 212 Users Manual ManualsLib Makes It Easy To Find Manuals Online!
2014-12-11
: Toro Toro-Greenkeeper-212-Users-Manual-121616 toro-greenkeeper-212-users-manual-121616 toro pdf
Open the PDF directly: View PDF .
Page Count: 39
Download | |
Open PDF In Browser | View PDF |
User’s Guide Automatic Sprinkler System Controller GreenKeeper 212 Features: ON PROGRAMS MANUAL START NEXT A B C OFF RR Downloaded from www.Manualslib.com manuals search engine • Easily Expandable Up To 12 Stations with 2-Station Plug-in Modules •3 Watering Programs With: - Calendar, Interval and Odd/Even Days - 1 Min. to 4 Hrs. Station Run Time - 4 Start Times Per Program •Battery Back-Up •Automatic Pump Start •Seasonal Run Time Adjust •Rain Delay •Rain Sensor Ready •Remote Control Ready •Snap-in Wire Connectors Table of Contents Controller Installation ■ Introduction and Set Up ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ GreenKeeper 212 Components......................2-5 Sprinkler System Basics ....................................6 Watering Program Basics ..................................7 Watering Program Details ..............................8-9 Planning Your Watering Schedule...................10 Filling Out the Watering Schedule Form.....10-11 ❚ Watering Schedule Form ..............................12 Programming Before Installation .....................13 Installing the Battery ........................................13 Selecting Optional Features ............................14 ❚ 24-Hour Clock Mode .....................................14 ❚ 15-Second Run Delay ..................................14 ❚ Odd/Even Watering Days..............................14 About the Controller Memory...........................14 Resetting the Controller Memory .....................15 ❚ To Reset the Permanent Memory .................15 ❚ To Clear the Memory ...................................15 ■ ■ Controller Operation ■ ■ Programming the Controller ■ ■ ■ ■ Setting the Current Time and Day or Date ......16 Setting the Watering Day Schedule............17-19 ❚ Setting a Calendar Schedule ........................17 ❚ Setting an Interval Schedule .........................18 ❚ Setting an Odd or Even Schedule.................19 ❚ Turning Off a Program .................................19 Setting Program Start Times ...........................20 Setting Station Run Times ...............................21 Indoor Model Installation ..............................22 ❚ Connecting the Valves ..................................23 ❚ Connecting a Pump Start Relay....................24 ❚ Connecting the Transformer .........................24 Outdoor Model Installation ...........................25 ❚ Preparing the Cabinet for Installation............25 ❚ Installing the Cabinet.....................................26 ❚ Connecting the Valves ..................................27 ❚ Connecting a Pump Start Relay....................28 ❚ Connecting the Power Source ................28–29 Connecting a Toro Rain Switch .......................29 ■ ■ ■ Automatic Operation .....................................30 Manual Operation ..........................................31 ❚ Starting Programs or Stations Manually........31 ❚ Watering Control Features ............................32 ❚ To Pause Watering .....................................32 ❚ To Resume Watering ..................................32 ❚ To Cancel Watering ....................................32 ❚ To Skip Zones.............................................32 ❚ To Adjust the Station Run TIme..................33 Turning Off the GreenKeeper 212 ...................33 Using the Rain Delay Feature..........................33 Using the Season Adjust Feature ....................34 Service and Specifications ■ ■ ■ ■ ■ ■ Replacing the Fuse..........................................35 Adding a Station Module..................................36 Troubleshooting ...............................................36 Specifications...................................................37 Warranty ..........................................................38 Electromagnetic Compatibility .........................38 1 GreenKeeper 212 Introduction and Set Up Controller Components 1 2 3 BATTERY 2 GreenKeeper 212 Components The following are brief descriptions of the controller components and display elements. Each of these items will be explained in further detail within the appropriate programming, operating and installation sections of this guide. 1 - LCD Display A - “Start Time” symbol – Alarm clock is displayed when setting the program start times. B - Program start time identification numbers 1–4. C - Main display of various time values and prompts. D - Program A, B and C identifiers. E - “Watering On” symbol – Water droplet indicates a watering station is running. Droplet flashes if watering is paused. F - “Watering Off” symbol – Water droplet with slash indicates all watering activity is Off. 2 - Control Buttons +/ON button – Increases the time display, scrolls forward through the program information and selects watering days. –/OFF button – Decreases the time display, scrolls backward through the program information and removes watering days. NEXT button – Advances to the next portion of program information. Resumes watering if paused. Advances through stations manually when watering. MANUAL START button – Selects and starts manual watering operations. 3 - Control Dial – Selects all controller programming and operation controls (except Manual Start). Control Dial Positions – The normal dial position for all automatic and manual operations. RUN G - “Power Off” symbol – Displayed when main power is disconnected and controller is on battery power only. CURRENT TIME/DAY H - “Low Battery Voltage” symbol – Indicates low battery voltage (when main power is disconnected). WATERING DAYS – Enables the watering day schedules to be set and reviewed. I - Watering Station identification numbers. PROGRAM START TIME – Enables the program start times to be set and reviewed. J - “Percent” symbol – Indicates the Season Adjust feature is in use. K - Day of the week identifiers. L - “Run Time” symbol – Hourglass is displayed when setting the watering station run times. – Enables the clock time and day to be set. STATION TIMES – Enables the station run time to be set and reviewed. (continued) 3 Controller Components 3 - Control Dial Positions (continued) – Enables the run time of all zones in a program to be simultaneously increased or decreased in 10% increments. OFF – Shuts off and prevents all automatic and manual watering activity. RAIN DELAY – Enables all watering operations to be delayed from 1 to 7 days. 4 - Program Select Switch – Three-position slide switch used to select watering program A, B or C during the programming procedures and manual operation. 5 - 12 or 24-Hour Clock Selector Jumper – Removing this jumper selects 24-hour (military time) clock mode. Jumper installed selects 12-hour clock mode. 6 - Run Delay Selector Jumper– Removing this jumper selects a 15-second delay period before a station begins watering. Jumper installed provides a 2-second delay. 7 - Odd/Even Day Schedule Selector Jumper – Removing this jumper enables an Odd or Even watering day schedule to be selected. 8 - Fuse – Domestic - 0.75A, 3AG (shown throughout manual). Export - 0.63A, (not shown). 9 - Battery Charger Switch – Controls the battery charging circuit. Switch positions provided for Alkaline (ALK) and rechargeable (RCHG) batteries. 10 - Rain Sensor Control Switch – Controls the sensor input circuit. Switch positions provided for sensor circuit On and Off. SEASON ADJUST 4 11 - Sensor Connection Terminals – Snap-in connectors for connection of an (optional) Toro Rain Switch. 12 - Valve Common Connection Terminal – Snap-in wire connector for the valve common wire. 13 - Pump/Master Valve Connection Terminal – Snap-in wire connector for a pump start relay or master valve. 14 - Transformer Connection Terminals – Snap-in connectors for the plug-in transformer wires. 15 - Plug-In Station Control Module – Each control module provides snap-in connectors for two station control valve power wires. Up to six modules can be installed. 16 - 9-Volt Battery – The battery maintains the controller memory if the transformer power is disconnected. Either an Alkaline or rechargeable Ni-MH battery can be installed. 17 - Power Supply – A Plug-in transformer supplies 24 V a.c. power to the indoor controller models. (Domestic transformer version shown.) 18 - Remote Control Receiver Jack – Modular jack provided for connection of the optional Toro Remote Control receiver cable. (Refer to the instructions provided with the remote control device for installation and operation details.) 19 - Transformer – A built-in transformer supplies 24 V a.c. power to the outdoor controller models. 20 - Terminal Block – Input power wire connection terminals for outdoor controller models. Controller Components 18 3 4 5 6 7 8 BATTERY 9 10 11 12 13 ON 14 15 16 PROGRAMS MANUAL START NEXT A B C OFF 19 BATTERY 18 17 20 16 5 Sprinkler System Basics The three main components of every automatic sprinkler system are the controller, station control valves and sprinklers. The controller is the brain of the system, telling the control valves when and how long to supply water to the sprinklers. The sprinklers direct and control the water applied to the lawn and plants. Each valve controls a specific group of sprinklers called a watering station. The stations are generally laid out and installed according to the type of plant material to be watered, the location of the plant within the landscape and the maximum amount of water which can be supplied. Each valve is connected to a numbered terminal within the controller, identifying it as Station 1, Station 2, etc. The controller operates the valves in order, one at a time. In other words, one station would water completely before another station would turn on. This is called a watering cycle. The information stored in the controller memory which determines when and how long the stations will water is called a program. The next section of this guide is very important. It explains what a program is and how the GreenKeeper 212 controls the operation of the sprinkler system. Valve 1 Controller ON PROGRAMS MANUAL START NEXT A B C OFF Valve 2 R Valve 3 House Valve 4 Valve 5 Valve 1 - Station 1 - Parkway Lawn - Fixed Spray Valve 2 - Station 2 - Front Lawn - Fixed Spray Valve 3 - Station 3 - Front Shrubs - Flood Bubbler Valve 4 - Station 4 - Back Lawn - Geared Rotor Valve 5 - Station 5 - Garden - Drip 6 Watering Program Basics A watering program requires three basic instructions to operate automatically: • What days to water –called watering days • When to water – called a program start time • How long to water – called station run time Watering Program Diagram Program Starts - 5:00 AM Station 1 12 6 The following example illustrates how a typical watering program could be set for the sprinkler system shown on the previous page. Example: The program start time is set for 5:00 AM. Lawn stations 1 and 2 each have a run time of 10 minutes and lawn station 4 is set to run for 20 minutes. Note that stations 3 and 5 water shrubs and flowers and have been excluded from this program. (These stations will be set to operate on separate programs). As shown in the watering program diagram, at 5:00 AM the controller starts the program watering cycle. Station 1 sprinklers run for 10 minutes and shut off. Station 2 sprinklers turn on, run for 10 minutes and shut off. The controller skips station 3 and turns on station 4, which runs for 20 minutes and shuts off. Station 5 is skipped and the watering cycle ends at 5:40 AM. As you can see from this example, only one program start time was needed to operate three different stations. Because of variations in plant watering needs, the GreenKeeper 212 provides three separate programs. The programs, called A, B and C, are completely independent of one another – like having three timers in one housing. 3 9 12 3 9 Station 2 6 12 3 9 Station 4 6 Program Ends- 5:40 AM Using more than one program for example, would enable lawn zones to be watered every day on program A, shrub zones to run on on Monday, Wednesday and Friday on program B and drip irrigation to soak the flower beds every three days on program C. Although the GreenKeeper 212 offers the multiple program feature, you may want to have all zones on one program if it meets your needs. The other programs can remain turned off until you need to use them. 7 Watering Program Details This section covers in detail each of the three parts of a watering program – watering days, program start times and station run times. Selecting Watering Days The GreenKeeper 212 provides four options for scheduling watering days: Calendar, Interval, Odd or Even and Off. Calendar Schedule A Calendar schedule enables you to select specific days of the week to water, for example, Monday, Wednesday and Friday. This is a seven-day schedule which starts on Sunday and ends on Saturday. This illustration shows how a Calendar schedule would be displayed when the control dial is in the WATERING DAYS position. In this example, program A has watering days set for MO (Monday), WE (Wednesday) and FR (Friday). This illustration shows how an Interval schedule would be displayed. In this example, program B has a 3-day Interval schedule which will start on Monday. PGM A B C 1 2 3 4 5 6 7 8 SU MO TU WE TH FR SA Odd/Even Schedule The Odd/Even schedule enables you to select odd or even numbered days of the month as watering days. This illustration shows how an Odd day schedule would be displayed. PGM A Program Off PGM A SU MO TU WE TH FR SA Interval Schedule 8 you can choose which day of the week will be the first day of the Interval. The number of days in the Interval determines the available start days. For example, if you have selected a 3-day Interval and today is Sunday, you may choose to start the Interval today, Monday or Tuesday. An Interval schedule enables you to set watering days without regard to the actual days of the week. For example, if you want to water every third day, you would select a 3-day Interval. Interval schedules range from 1-day (watering every day) to 7-day (watering every seventh day). Once you have selected an Interval schedule, Selecting OFF suspends the operation of the program when it is not needed. Turning the program off does not alter or erase the watering day schedule of the program, it simply places the program on hold until it is needed. This illustration shows how a program would be displayed if its watering day schedule is turned off. In this example, program C is off. Selecting Program Start Times Setting the Station Run Time A program start time is the time of day you select to begin an automatic program watering cycle. It is important to remember that a program only requires one start time to operate automatically. When a program starts, each station assigned to the program will water in numerical order, one at a time for its set run time. A station run time is the length of time the station (controlled by the valve) will water during the program watering cycle. The run time for each station can be set from Off (no run time) to 4 hours, in one-minute increments. Sometimes it is necessary to run a watering program more than one time per day. For example, when growing a new lawn. The GreenKeeper 212 enables each program to have up to four separate start times per day. Program start times are numbered 1 through 4. These numbers are shown at the top left of the display next to the start time symbol when the control dial is in the PROGRAM START TIME position and indicate how many start times are currently set for the program. This illustration shows how a program start time is displayed. In this example, program A has one start time (start time number 1) set for 5:00 AM. A station is assigned to a program when it is given a run time. If the run time for a station is turned Off in a program, it will not operate during the program watering cycle. This is how the GreenKeeper 212 enables you to assign stations to different programs. All stations assigned to the program are shown on the lower portion of the display when the control dial is in the STATION TIMES position. This illustration shows how a station run time is displayed for a program. In this example, zones 1–6 are assigned to program A. Station 1 has a 10-minute run time and station 2 is set to run for 25 minutes. The station run time being displayed is identified by the flashing station number. Flashing Flashing 9 Planning Your Watering Schedule It is always helpful to plan your watering schedule on paper before beginning the programming steps. You will have a record of your watering schedule and station locations which can be kept with your GreenKeeper 212 after it is installed. If you have an indoor model controller, a watering schedule form is provided on page 12 for you to fill out then remove to keep with the controller. This form is duplicated on a decal located on the inside cover of the outdoor model. ◆ Guidelines for Watering There are several factors to be considered when deciding when and how long to water. For example, the soil type (i.e., clay, loam, etc.), the part of the landscape being watered, climate conditions and the type of sprinklers being used. Because of these variables, we cannot provide an exact schedule to follow, but here are some general watering guidelines to help you get started. • Water early in the morning, one to two hours before sunrise. You will have the best water pressure at this time and the water can soak into the plant root zone while evaporation is minimal. Watering during mid-day or in the evening may cause plant damage or mildew. • Watch for signs of under- or over-watering and make program adjustments immediately. Filling Out the Watering Schedule Form 10 When filling out this form, use a pencil so changes can be easily made. After installing the indoor model controller, remove the form and store it in the pocket formed between the mounting bracket and the back of the controller housing. Refer to the example form shown on the opposite page and fill out your form in a similar manner with the following information: • Location - Identify the location of each watering station and the type of plant being watered. Note: Enter the following information for each program. If the program is not needed, leave its information column blank. • Watering Day Schedule - For a Calendar schedule, indicate which day(s) of the week watering is desired. For an Interval schedule indicate the desired Interval number. For Odd or Even days, simply mark the appropriate box. • Station Run Time - Indicate the amount of run time (1 minute to 4 hours) for each station. Write “Off” for any station which you do not want to operate in the program. • Program Start Times - Indicate the time of day to start the program. Each program can have 1 to 4 start times per watering day. Note: The GreenKeeper will run only one watering cycle at a time. Therefore, when using multiple start times within a program or when using multiple programs, make sure that each watering cycle will be able to run completely before the next watering cycle is scheduled to start. A program start time that occurs while a watering cycle is in progress will be delayed until the current watering cycle is finished. (Example) 11 Watering Schedule Form PROGRAM A CALENDAR WATERING DAY SCHEDULE ODD/EVEN ZONE 1 2 3 4 12 3 4 5 6 EVEN STATION RUN TIME 1 2 3 4 5 6 7 8 9 10 11 12 PROGRAM START TIMES 2 ODD LOCATION PROGRAM C SU MO TU WE TH FR SA SU MO TU WE TH FR SA SU MO TU WE TH FR SA 1 INTERVAL PROGRAM B 7 1 2 ODD 3 4 5 6 EVEN STATION RUN TIME 7 1 2 ODD 3 4 5 6 EVEN STATION RUN TIME 7 Programming Before Installation The GreenKeeper 212 utilizes a 9-volt battery to retain its watering program information in the event of a main power interruption. This battery backup feature also enables your controller to be fully programmed for operation right out of the box—before installation—in the comfort of your home. Simply attach the battery and begin the programming steps. The program information will be retained for the duration of the battery life – about 72 hours for an Alkaline battery or 24 hours for a rechargeable NickelMetal Hydride (Ni-MH) battery. Installing the Battery Note: The 9-volt battery does not supply enough voltage to operate the station control valves. 1. Indoor models: Slide the lower housing cover toward the bottom of the controller to remove. Outdoor models: Pull outward on the lower housing cover handle to remove. Locate the battery wire clip and attach it to the battery terminals. Place the battery into the cabinet compartment as shown in Figure 1. Figure 1 2. The display will begin flashing 12:00 AM. Press the +/ON button to stop the display from flashing. The colon (:) will continuously flash while displaying the time and during watering operation. The Power Off symbol will be displayed until the main power supply is connected. 3. Locate the battery charger Figure 2 switch (9) as indicated in Figure 2. If an Alkaline battery is installed, the switch must be set to the left position (ALK) to turn the charging circuit off. If a 9 rechargeable Ni-MH battery is used, the switch must be set to the right position (RCHG) to turn the charging circuit on. BATTERY Caution: The battery charger switch must be set correctly. Damage to the controller can result from an Alkaline battery which may fail if charged. 4. Reinstall the lower housing cover. WARNING: Always replace battery with the same or equivalent type. Dispose of used batteries according to the battery manufacturer’s recommendations. Indoor Controller Outdoor Controller 13 Selecting Optional Features 24-Hour Clock Mode The GreenKeeper 212 is set to display time in the 12-hour clock mode. If you prefer to use a 24-hour clock mode (military time), select this option by removing the 12/24 Hour Selector Jumper (5). To store the jumper, install it on one pin as shown. See Figure 3. Figure 3 BATTERY 15-Second Run Delay The 15-second run delay feature is useful for sprinkler systems utilizing a pump or master valve. For example, a pump usually requires a few seconds to build pressure after first starting. With the 15-second run delay selected, the pump would be running (or the master valve would open) 15 seconds before the first station begins watering. A 15-second delay would also occur between station operations. This helps ensure that one valve is closed before another valve opens. Note: A 2-second run delay will occur if this option is not selected. To select the 15-second delay option, remove the Delay Selector Jumper (6). See Figure 3. Odd/Even Watering Days 14 If you plan to use an Odd/Even day watering schedule, remove the Odd/Even Selector Jumper (7) for this option. About the GreenKeeper 212 Memory The GreenKeeper 212 has a permanent watering schedule within its memory to assist you in two ways. First, it will restore watering operation in case your watering program is lost due to a power interruption lasting longer than the battery backup reserve. This prevents your landscape from going unwatered if the power outage occurs while you are away. Secondly, if you do not want to program your GreenKeeper 212, you can use the permanent watering schedule to operate your sprinklers. Just set the current time and day and your GreenKeeper 212 will be ready to operate automatically. The permanent watering schedule operates as follows: When power is applied, the controller clock is set to 12:00 AM Sunday. Program A has a Calendar watering schedule set to water every day. One program start time is set for 5:00 AM (5:00) and a run time of 10 minutes is set for each station. Programs B and C are turned Off and have no program start times or run times. Note: An optional feature is provided which enables the The GreenKeeper 212 memory to be reset to the permanent program or cleared completely if you choose. If you do not want to use this option, skip the next procedure “Resetting The Controller Memory” and continue at page 16 to begin programming. Resetting the Controller Memory The GreenKeeper 212 program memory can be reset to the permanent program values or cleared completely at any time without removing power. Figure 4 2 3 Resetting the permanent program erases all user input and replaces it with the permanent program values. Clearing the program memory sets all program values to Off (i.e., no active days, program start times or station run times). You may find that this simplifies programming the controller if your watering requirements are quite different than the permanent values. 1 2 Note: When power is first applied, the GreenKeeper 212 will always reset to the permanent program values. To Reset the Permanent Program (Figure 4) Turn the control dial to the OFF be displayed. Figure 5 2 position. OFF will 3 Press the +/ON and –/OFF buttons at the same time until CLR is displayed. Return the control dial to the RUN 2 position. 1 To Clear the Memory (Figure 5) Turn the control dial to the OFF be displayed. position. OFF will Press the +/ON and NEXT buttons at the same time until CLR 0 is displayed. Return the control dial to the RUN position. 15 Example 1 Programming the Controller Setting the Current Time and Day or Date SU Note: To select the 24-hour clock mode, see page 14. Turn the control dial to the CURRENT TIME/DAY position (the hour digits will begin flashing). To adjust the display, press the +/ON button to scroll the digits forward or the –/OFF button to scroll the digits backward. Note: The display will begin to change rapidly if either button is held down for more than two seconds. Press the NEXT button to select the next portion of the display. 4. Repeat step 2 and 3 to set the current minutes. Note: If the Odd/Even Jumper is removed, the current year, month and day must be set. Continue at step 7 for this procedure. If this option is not selected, set the current day by continuing at step 5. Refer to Example 1. To set the current day, press the +/ON button to scroll forward or the –/OFF button to scroll backward until the current weekday is displayed. The weekday abbreviations are as follows: SU (Sunday) MO (Monday) TU (Tuesday) WE (Wednesday) TH (Thursday) FR (Friday) SA (Saturday) 16 When the current time and day are displayed, return the control dial to the RUN position. Example 2 7 10 8 7 SU Day Month 7 8 7 To adjust the display, press the +/ON button to scroll the digits forward or the –/OFF button to scroll the digits backward. Refer to Example 2. Press the NEXT button to select the next portion of the display. 9. Repeat steps 7 and 8 to set the current month (first two digits) and the day (second two digits). When the current time and date are set, return the control dial to the RUN position. Setting the Watering Day Schedule For each program, you can select Calendar, Interval Odd, Even or Off. To set a Calendar schedule, continue here. To set an Interval schedule see page 18. To set an Odd or Even schedule see page 19. To turn Off a program, see page 19. 2 3 PGM A 7 SU MO TU WE TH FR SA 4 3 5 5 1 4 Setting a Calendar Schedule Turn the control dial to the WATERING position. DAYS Check the PROGRAMS switch setting. If necessary, reposition the switch to select the desired program. 2 3 5 6. To set a Calendar schedule for another program, repeat all of the steps beginning at step . The current watering schedule will be displayed. If CAL (Calendar) is not displayed, press the +/ON or –/OFF button as needed to select CAL. When you have completed setting the Calendar schedule for each program (as needed) return the control dial to the RUN position. Press the NEXT button. The watering days currently set for this program will be displayed. SU (Sunday) will begin flashing. Note: Each program can have its own Calendar, Interval or Odd/Even schedule, but only one schedule can be active at a time for that program. The watering day schedule or OFF shown in the display when the control dial is in the WATERING DAYS position, will be the current schedule for that program. To select Sunday as a watering day, press the +/ON button. To remove Sunday from the schedule, press the –/OFF button. MO (Monday) will now begin flashing. Continue to select or remove each day of the week until only the desired watering days are shown. 17 Setting an Interval Schedule Turn the control dial to the WATERING position. Check the PROGRAMS switch setting. If necessary, reposition the switch to select the desired program. The current watering schedule will be displayed. If Int (Interval) is not displayed, press the +/ON or –/OFF button as needed to select Int. Press the NEXT button. The current Interval number (1–7) will begin flashing. The day of the week on which the Interval will start will be shown. To change the Interval number, press the +/ON or –/OFF button until the desired number is flashing. Press the NEXT button. The Interval start day will begin flashing. To change the Interval start day, press the +/ON button or the –/OFF button until the desired day is flashing. 8. To set an Interval schedule for another program, repeat all of the steps beginning at step . 18 3 DAYS 2 PGM A 3 9 MO 6 7 4 5 3 5 7 1 4 6 2 3 5 7 When you have completed setting the Interval schedule for each program (as needed) return the control dial to the RUN position. Setting an Odd or Even Schedule Turning Off a Program Note:The Odd/Even Selector Jumper must be removed for this type of watering schedule. See page 14 for details. Note: Turning off a program does not alter or erase a preset watering day schedule. Selecting Off simply places the program on hold until one of the watering day schedules is selected. Turn the control dial to the WATERING position. DAYS Check the PROGRAMS switch setting. If necessary, reposition the switch to select the desired program. Turn the control dial to the WATERING position. The current watering schedule will be displayed. If Odd or Even is not displayed, press the +/ON or –/OFF button as needed to select Odd or Even. Check the PROGRAMs switch setting. If necessary, reposition the switch to select the desired program. Note: When Odd is selected, the 31st day of the month and the 29th day of a leap year will not be active watering days. DAYS Press the +/ON or –/OFF button until OFF is flashing. 4. To turn another program Off, repeat steps as needed. Return the control dial to the RUN and position. 4. To set an Odd or Even schedule for another program, repeat steps and as needed. When you have completed setting the Odd or Even schedule for each program as needed, return the control dial to the RUN position. 3 3 2 PGM C 5 3 2 PGM 1 B 5 3 2 3 1 2 3 19 Setting Program Start Times Turn the control dial to the PROGRAM position. 2 9 3 START TIME 1 2 PGM A AM Check the PROGRAMS switch setting. If necessary, reposition the switch to select the desired program. Program start time number 1 will begin flashing. The current program start time or OFF will be displayed for start time number 1. To select a different program start time number, press the +/ON or the –/OFF button until the desired number is flashing. Note: The numbers (1–4) shown at the top of the display designate program start times and should not be confused with station numbers. The station numbers will be shown at the bottom of the display when setting zone run time. 4 5 6 7 3 5 7 9 4 6 8 1 2 3 5 7 9 To select another start time number, press the +/ON or the –/OFF button until the desired start time number is flashing. Press the NEXT button. The hour digit(s) or OFF will begin flashing. 10. To set, change or remove a program start time for the start time number selected, repeat all of the steps starting at step . Note: To remove the start time, select OFF by pressing the +/ON and –/OFF buttons at the same time, and continue at step . 11. To set program start times for another program, repeat all of the steps starting at step . To set the hour (and AM/PM), press the +/ON or the –/OFF button until the desired hour is flashing. Press the NEXT button. The minute digits will begin flashing. To set the minutes, press the +/ON or –/OFF button until the desired minute is flashing. 20 12 Press the NEXT button. The next program start time number will begin flashing. Return the control dial to the RUN position. Setting Station Run Times Turn the control dial to the position. 2 STATION TIMES 4 5 PGM A Check the PROGRAMS switch setting. If necessary, reposition the switch to select the desired program. 9 1 2 3 4 5 6 Press the NEXT button. The run time (or OFF) will begin flashing. 3 5 3 Station number 1 will be flashing and its current run time or OFF will be shown. To select a different station number, press the +/ON or –/OFF button until the desired station number is flashing. 4 5 1 2 3 5 To set the run time, press the +/ON or –/OFF button until the desired run time is shown. Note: To remove the run time, select OFF by pressing the +/ON and –/OFF buttons at the same time. Press the NEXT button. The next station number will begin flashing. 7. Repeat steps and as needed to set, change, or remove the run time for the remaining stations. 8. To set the station run time for another program, repeat all of the steps starting at step . Return the control dial to the RUN position. 21 A Controller Installation F B Note: The GreenKeeper 212 indoor controller is not weather resistant and must be installed indoors or in a protected area. For outdoor installation of an indoor model, a weather-resistant outdoor cabinet is available. Order model number GK212-CAB-01 for domestic controllers or GK212-CAB-02 for export controllers. C Indoor Model Installation 1. Select a location for the controller within 4' (1.2m) of an electrical outlet to enable the transformer wires to easily reach. Make sure the outlet is not controlled by a light switch. 2. Remove the mounting bracket attached to the back of the controller housing by pulling the lower edge of the bracket away and downward from the controller housing. 22 E D 3. Place the mounting bracket (A) against the wall aligning the top edge at about eye level. Drive three 1" (25mm) wood screws (B) into the wall through the three holes provided in the bracket. 5. Align the slotted openings on the back of controller housing with the mounting bracket tabs. Slide the controller downward to engage the tabs. Note: If you are installing the bracket on drywall or masonry, install screw anchors (C) to prevent screws from loosening. Note: After installation, store the Quick Reference Guide and the Watering Schedule Form in the pocket (F) behind the controller. 4. Optional - Insert 3/4" (19mm) PVC conduit (D) for valve wiring into bracket sleeve (E). Connecting the Valves PROGRAMS A B C 1. Route the valve control wires between the valves and the controller. Note: Using 18 AWG (1.0mm2) multi-wire sprinkler valve connection cable is recommended. This cable is insulated for direct burial and is color-coded to simplify installation. OFF BATTERY 2. Attach the white color-coded wire from the cable to one wire from each valve solenoid. (Either solenoid wire can be used for this connection.) This is called the valve common wire. 3. Attach a separate cable wire to the remaining wire from each valve solenoid. Make a note of the wire color code used for each valve and the watering station it controls. You will need to have this information when connecting the valve wires to the controller. 4. Secure all wire splices using twist-on wire connectors. To prevent corrosion and possible short circuits, use a grease cap or similar waterproofing method to insulate each connection. 5. Route the wire cable into the controller through the large opening in the base of the housing or through PVC conduit if it is installed. Strip insulation back 1/2" (13mm) from all cable wires. Master Valve Valve Common Wire Station Valves 6. Referring to the Controller Components on page 5 and the diagram above, secure the valve common wire to the terminal labeled COM (12). Connect the individual station valve wires to the appropriate station module terminals (15). Connect the master valve wire (if applicable) to the terminal labeled PUMP/MV (13). Note: Connecting a master valve or pump start relay is optional and may not be required in your sprinkler system. Note: The GreenKeeper 212 has snap-in wire terminals. To attach wires, simply raise the lever, insert the stripped wire, and press the lever down to secure. 23 Connecting a Pump Start Relay Connecting the Plug-In Transformer (Optional) Note: For model GK212-26-04, contact your Toro distributor for the recommended transformer. CAUTION: To prevent controller damage, ensure the relay current draw does not exceed 0.30 Amps. Do not connect the controller directly to the pump starter. CAUTION: Do not plug the transformer into an electrical outlet until all of the wiring procedures have been completed. 1. Route a wire pair from the pump relay into the controller housing. 1. Route the cable from the transformer (17) through the small opening provided in the base of the housing. Wrap the cable around the post as shown below. 2. Connect one wire to the terminal labeled COM (12). Connect the remaining wire to the terminal labeled PUMP/MV (13) as shown below. 1 2 3 5 4 6 7 8 UN TIMES BATTERY 14 1 2 3 4 5 6 7 8 9 10 Jumper Wire 17 9V Pump Relay 24 Valve Common Wire CAUTION: To prevent pump damage due to “Dead-heading,” connect a jumper wire from any unused station terminal to a station terminal with a valve connected. 2. Connect one transformer cable wire to each terminal labeled 24 VAC (14). The wires can be connected to either terminal. Outdoor Model Installation ON PROGRAMS MANUAL START NEXT A B C OFF PROG RAMS A B C ON ON MA MANUNUAL ST AL STARAR T T NE NEXTXT B OF OFF F BATTERY RR C A Preparing the Cabinet for Installation 1. Remove the lower housing cover (A) by pulling outward on the handle. 2. Remove two phillips screws from the transformer access cover (B). Pull the cover outward from the bottom to remove. 3. Three lower mounting holes (C) are provided. The center hole is open and the outer holes are plugged. If you intend to use the outer holes for installation, carefully drill through the plugs with a 3/16" (5mm) drill bit. D E F G Four wiring access holes are provided in the cabinet base as follows: (D) - 1/2" (13mm) for power and equipment ground wires. (E) - 1/2" (13mm) (plugged) for optional Toro Rain Switch wires. (F) - 3/4" (19mm) for sprinkler valve wires. (G) - 1/2" (13mm) (plugged) for optional Toro remote control cable. 4. If planning to install the optional Toro components, remove the plugs as necessary. 25 Installing the Cabinet 1. For safe, reliable operation, select an installation site which will provide the following conditions: • Protection from irrigation spray, exposure to direct sun during the hottest hours, wind and snow. • Access to a grounded power source which is not controlled by a light switch or utilized by a high current load appliance, such as a refrigerator or air conditioner. • Access to the sprinkler control valve wiring and optional accessory wiring. A B 6" (15.24cm) 2. Drive a wood screw (provided) into the wall at eye level (A). Leave the screw extended approximately 1/4" (6.5mm) from the wall. Note: If you are installing the controller on drywall or masonry, install screw anchors to prevent screws from loosening. Use the dimension shown to predrill holes for screw anchors. ON PROGRAMS 3. Hang the cabinet on the screw using the keyhole slot (B) on the back panel. Make sure the cabinet slides down securely on the screw. OFF BATTERY Note: Conduit and adapters are not provided. Install conduit as required by local electrical codes. 26 Note: After installation, store the User’s Guide and Quick Reference Guide on the hook located on the inside of the door. NEXT A B C 4. Install the lower mounting screw(s) and tighten securely. 5. Install 1/2" (13mm) conduit (C) for power/equipment ground wires and 3/4" (19mm) conduit (D) for valve wires. MANUAL START C D Connecting the Valves PROGRAMS 1. Route the valve wires or wire cable from the valves, into the controller cabinet. Note: Using 18 AWG (1mm2) multi-wire sprinkler valve connection cable is recommended. This cable is insulated for direct burial and is color-coded to simplify installation. START A B C OFF BATTERY 2. Attach the white color-coded wire from the cable to one wire from each valve solenoid. (Either solenoid wire can be used for this connection.) This is called the valve common wire. 3. Attach a separate cable wire to the remaining wire from each valve solenoid. Make a note of the wire color code used for each valve and the watering station it controls. You will need to have this information when connecting the valve wires to the controller. 4. Secure all wire splices using twist-on wire connectors. To prevent corrosion and possible short circuits, use a grease cap or similar waterproofing method to insulate each connection. 5. Strip back 1/2" (13mm) of insulation from all cable wires at the other end of the valve connection cable. Note: The GreenKeeper 212 has snap-in wire terminals. To attach wires, simply raise the lever, insert the stripped wire, and press the lever down to secure. Master Valve Valve Common Wire Station Valves 6. Referring to the Controller Components on page 5 and the diagram above, secure the valve common wire to the terminal labeled COM (12). Connect the individual station valve wires to the appropriate station module terminals (15). Connect the master valve wire (if applicable) to the terminal labeled PUMP/MV (13). Note: Connecting a master valve or pump start relay is optional and may not be required in your sprinkler system. 27 Connecting a Pump Start Relay (Optional) CAUTION: To prevent controller damage, ensure the relay current draw does not exceed 0.30 Amps. Do not connect the controller directly to the pump starter. 1. For pump relay wires, install a 1/2" (13mm) conduit adapter and conduit. 2. Connect a wire pair to the pump relay terminals and route the cable through the conduit and into the controller housing. 3. Connect one wire to the terminal labeled COM (12). Connect the remaining wire to the terminal labeled PUMP/MV (13) as shown below. BATTERY Jumper Wire 12 Connecting the Power Source WARNING: AC power wiring must be installed and connected by qualified personnel only. All electrical components and installation procedures must comply with all applicable local and national electrical codes. Some codes may require a means of disconnection from the AC power source installed in the fixed wiring and having a contact separation of at least 0.120" (3mm) in the line and neutral poles. Make sure the power source is OFF prior to connecting the controller. 1. Route the power and equipment ground wires from the power source, through the conduit and into the controller transformer compartment. Note: The controller terminal block accepts wire size up to 12 AWG (4mm2). 2. Remove 3/8" (10mm) insulation from the wire ends. 13 3. Using a small flat blade screwdriver, secure the wires as shown to the terminal block as follows: Line or Line 1 (L1) to L, Neutral or Line 2 (L2) to N and Equipment Ground to . Pump Relay 28 Valve Common Wire CAUTION: To prevent pump damage due to “dead-heading,” connect a jumper wire from any unused station terminal to a station terminal with a valve connected. 4. Install and secure the transformer compartment cover. 5. Apply power to the controller. Connecting the Power Source (cont.) BATTERY A SE DJ A 1. Route the wire cable Toro Rain Switch from the Toro Rain S USON T Switch into the conSET VALVE RUN TIMES troller housing through the access hole provided. 2. The Rain Switch cable 10 has four wires: two copper wires and two silver 2 1 11 wires. Connect the heavier 18 AWG (1.0mm2) copper wire and the thinner 24 AWG (0.50mm2) silver wire to the terminals labeled SENSOR (11). Trim off the remaining two wires. 3. Set Sensor Switch (10) as required: ON allows the Rain Switch to interrupt watering; OFF bypasses the Rain Switch input. SE S BATTERY Connecting a Toro Rain Switch (Optional) The Toro Rain Switch is a remote rain sensor which can be connected directly to your GreenKeeper 212 to automatically interrupt watering during rain. A sensor bypass switch is provided which enables the Rain Switch operation to be turned On and Off. When the Rain Switch absorbs rain water it automatically signals the GreenKeeper 212 to suspend all watering operations. The “No Watering” symbol will appear in the upper right corner of the display until the Rain Switch drys out and automatically resets. The “No Watering” symbol will disappear and controller operation will resume as programmed. Note: The Toro Rain Switch is a normally closed device. To install a normally open Rain Switch, refer to the instructions provided with the device and and install accordingly. 29 Controller Operation The GreenKeeper 212 controller has three modes of operation: Automatic, Manual and Off. In the Automatic mode the controller tracks the time and day and operates the automatic watering schedules. The Manual mode enables the watering programs to be started and controlled manually at any time. The Off mode shuts off all watering activity and prevents any zones from operating automatically or manually. The Rain Delay and Season Adjust control features are provided to enable quick, temporary changes in operation to help compensate for variables in weather and season. Each of the operating modes and control features are explained in this section of the guide and can be found on the following pages: • • • • • • Automatic Operation, page 30 Manual Operation, page 31 Watering Control Features, page 32 Turning Off The GreenKeeper 212, page 33 Using the Rain Delay Feature, page 33 Using the Season Adjust Feature, page 34 Automatic Operation 30 In the Automatic mode, the GreenKeeper 212 keeps track of the current time, day of the week and the automatic watering program schedule. Automatic operation will occur whenever a programmed watering day and start time match the current time and day. The Automatic mode is selected when the control dial is in the RUN position. While in the automatic mode, the display will show two types of information: status and operation. This illustration shows the status display. In this example the current time is 2:45 PM and the current day is Monday. Programs A and B are active on Monday. PM MO When watering starts, the operating display appears and is shown for the duration of the program. In this example, program A is operating. Station 1 is watering and has 10 minutes of run time remaining. Zones 2, 3 and 4 will operate during this program. Program B is also programmed to run today. Flashing 5 6 Flashing Note: If the control dial remains in any other position (except OFF) for more than 8 minutes, the controller reverts to the Automatic mode. Note: The position of the PROGRAMS switch does not determine which program will run during automatic controller operation. In other words, if a program has an assigned watering day schedule, start time and a station with run time, it will operate automatically regardless of the position of the PROGRAMS switch. Manual Operation Manual operation enables the automatic watering programs or selected stations assigned to the program to be started manually. During operation, temporary changes can be made to increase or decrease the station run time, step through the station sequence and pause or stop watering using the “Watering Control Features” described on page 32. Upon completion of the manual watering operation, the controller will return to the Automatic mode. Starting Programs and/or Stations Manually You may operate all stations or selected stations in each program. Watering programs can be started individually or set to start in order. When one program finishes the next selected program will operate. Ensure the control dial is in the RUN position. Position the PROGRAMS switch to select the program you wish to start. Choose one of the following manual operations: • To operate the selected program with all assigned stations, press the MANUAL START button two times to begin watering. • To operate only selected stations, press the MANUAL START button, then press the +/ON button to select the flashing zone number, or press the –/OFF button to skip the zone number. Continue selecting or omitting zones in this manner. When only the desired zones are displayed, press the MANUAL START button again to begin watering. Flashing Flashing 1 PGM A B 1 2 3 4 5 6 3 3 2 3 Example: Program A is operating. Program B will start when program A is finished. 4. To select additional programs, repeat steps and . Note: Additional programs set to start will operate one at a time in alphabetical order. Each program letter will be displayed as it is selected. The program currently operating is indicated by the flashing program letter. 31 Watering Control Features The following watering control features enable you to further control the watering program during operation. All watering control features apply to watering programs started manually and automatically. To Pause Watering To Cancel Watering Press the +/ON and –/OFF buttons at the same time two times. • All watering operations will be canceled and the controller will return to the automatic mode. Note: Placing the control dial in the OFF position for two seconds, then back to RUN will also cancel all watering operations. Press the +/ON and –/OFF buttons at the same time. • The station currently watering will shut off. To Skip Stations • The “Watering On” symbol will begin flashing. Press the NEXT button one time. • The display will show the amount of run time remaining for the paused station. Note: If watering is not resumed within 8 minutes, all watering operations will be canceled and the controller will return to the automatic mode. • The station currently watering will shut off and the next station will start. • If the last station is skipped, the program will end. If additional programs have been set to operate, the next program in alphabetical order will start. To Resume Watering (when paused) To Adjust the Station Run Time Press the NEXT button. Press the +/ON button to increase run time or the –/OFF button to decrease run time. • Watering activity will resume from the point of interruption. • If the station run time is decreased to less than 1 minute, the station will shut off. The next station in sequence will start. • The station run time is changed during this operation only. The program memory will not be changed. 32 Turning Off the GreenKeeper 212 Flashing When the control dial is turned to the OFF position, the controller immediately shuts off any watering operation currently in progress. Leaving the control dial in the OFF position will prevent all automatic and manual watering operations. The controller will continue to track the current time and day of the week. PM 1 3 MO 2 For extended shutdown of the sprinkler system leave the control dial in the OFF position. The word OFF will be displayed for 8 minutes. The automatic status display will then appear. Automatic operation is resumed by turning the control dial to the RUN position. 2 PM MO Using the Rain Delay Feature This feature enables all watering operations to be delayed from 1 to 7 days. For example, rain is forecast in your area for the next two days. Instead of turning the controller off (and possibly forgetting to turn it back on), a rain delay of 3 days can be easily entered. At the end of 3 days, the controller will resume automatic operation as scheduled. Turn the control dial to the RAIN DELAY position. The rain delay display will begin alternating with the automatic status display. To set the number of rain delay days, press the +/ON or –/OFF button until the desired number (1–7) is flashing. Return the control dial to the RUN position. Note: The rain delay number will automatically decrease as each day passes. When the number reaches 0 (zero), automatic operation will resume at the next scheduled start time. To cancel the rain delay, turn the control dial momentarily (3 seconds) to the OFF position. 33 Using the Season Adjust Feature Changes in season and temperature generally require a change in station run time to maintain a healthy landscape and conserve water. The season adjust feature enables you to change the run time of all zones assigned to a program, simultaneously up or down, in 10% increments – with just the press of a button. Adjustments can be reduced to 10% or increased to 200% of the programmed run time of each station. A 50% setting, for example, would decrease a 20-minute station run time to 10 minutes. Increases however, work a little differently. With any adjustment above 100%, the GreenKeeper 212 will first increase the run time by the adjustment percentage, then split the time in half and run the watering program twice. This allows the water to soak in instead of pooling or running off. For example, adjusting to 150% would first increase a 20-minute station run time to 30 minutes, then split the time in half and run two watering cycles back-to-back with 15 minutes in each operation. During operation the % symbol will flash to indicate a multiple watering operation. Note: All station run times are retained in the controller memory and returned to their set value when the season adjust is reset to 100%. The only time a station run time will appear changed is during operation. 34 % 5 3 1 2 3 Turn the control dial to the SEASON ADJUST position. The season adjust display will be shown and 100% will be flashing. Check the PROGRAMs switch setting. If necessary, reposition the switch to select the desired program. Press the +/ON or –/OFF until the desired adjustment value is flashing. 4. To apply the Season Adjust feature to another program, repeat steps and . Return the control dial the RUN position. Service and Specifications Adding a Station Module 1. Turn the control dial to the OFF position. The fuse protects the controller from damage due to power surges and excessive current draw through the Station Modules. Before replacing the fuse, check for the probable cause, such as a shorted or improperly connected control valve wire, then replace the fuse as follows: WARNING: For continued protection against risk of fire, replace only with the same type and rating of fuse. Remove the controller power source prior to servicing the fuse. Failure to comply may result in serious injury and/or controller damage. 1. Unplug the transformer from the wall receptacle. (indoor model) or shut off power at the source (outdoor model). 2. Remove the lower housing cover from the controller. 3. Carefully remove the blown fuse from the retaining clip. (See page 5 item 8 for fuse location.) 4. Remove the replacement fuse from the back side of lower housing cover (indoor model) or the lower inside corner of the door (outdoor model) and install it into the fuse retaining clip. 2. Remove the lower front cover from the controller housing by sliding it downward. 12HR Replacing the Fuse 24HR 1 2 3 4 7 8 3. Place the back of the station control module (model number MOD 212-02) squarely between the guides of the first open expansion slot (from left to right). Pushing lightly on the bottom of the module, slide it upward until it locks into position. 4. To connect the valve wires, refer to “Connecting The Valves” on page 23 or 27. 5. Install the lower front cover. 6. To set the station run time, refer to “Setting Station Run Times” on page 21. 7. To test the operation of the new watering station(s), refer to “Manual Operation” on page 31. 5. Install the lower housing cover. 6. Apply power to the controller. 35 Troubleshooting If you are having a problem with the controller, check the following symptoms, possible causes and remedies. If the problem cannot be resolved or you would like assistance with any Toro irrigation product, call our toll-free Toro Help Line, 1-800-664-4740 Monday through Friday, 7:30 AM – 4:00 PM (Pacific Standard Time). 36 Symptom Possible Cause Remedy The display is blank and the controller does not operate. The battery is dead and one or more of the following causes: Replace the battery and one or more of the following: Blown fuse. Replace the fuse. See page 35. Main power is disconnected. Check the transformer connections (indoor model) or circuit breaker service panel (outdoor model). Watering programs start at unscheduled times. Watering programs have overlapping schedules. Shorten station run times and/or space start times farther apart. Watering station does not turn on. Faulty control valve wire connections. Check the wire connections at the control valve and controller. Station run time is turned Off. Enter a station run time. See page 21. Watering station does not turn off. Control valve problem. Inspect, clean and/or repair valve as needed. Program restarts unexpectedly after the completion of an automatic operation. More than one start time on the program. Remove additional program start times. See page 20. Season Adjust setting greater than 100%. Set SEASON ADJUST See page 34. to 100%. Specifications Cabinet Dimensions: Indoor Model 7.5" W x 8.5" H x 2" D (19cm W x 21.6cm H x 5cm D) Outdoor Model 13.25" W x 9" H x 3.5" D (33.7cm W x 22.9cm H x 9cm D) Power Specifications: Indoor Model - Domestic Plug-in Transformer, Class 2, UL Listed, CSA Certified (or equivalent) • Input: 120 V a.c. 60 Hz, 0.5A • Output: 24 V a.c. 60 Hz, 18 VA Indoor Model - Export Plug-in Transformer, TUV Approved • Input: 230 V a.c. 50Hz, 0.1A • Output: 24 V a.c. 50 Hz, 18 VA Indoor Model - Australia Plug-in Transformer, SAA Approved • Input: 240 V a.c. 50Hz, 0.1A • Output: 24 V a.c. 50 Hz, 18 VA Outdoor Model - Domestic Built-in Transformer, Class 2, UL Listed, CSA Certified (or equivalent) • Input: 120 V a.c. 60 Hz, 0.5A • Output: 24 V a.c. 60 Hz, 20–30 VA Power Specifications (continued): Outdoor Model - Export Built-in Transformer, TUV Approved, SAA Approved • Input: 230/240 V a.c. 50/60 Hz, 0.1A • Output: 24 V a.c. 50/60 Hz, 20 VA Outdoor Model - Australia Built-in Transformer, SAA Approved • Input: 230/240 V a.c. 50/60 Hz, 0.1A • Output: 24 V a.c. 50/60 Hz, 20 VA Maximum Load Per Station: 0.30 Amps @ 24 V a.c. Maximum Load For Pump/Master Valve: 0.30 Amps @ 24 V a.c. Total Maximum Output: (one station plus pump), not to exceed 0.60 Amps @ 24 V a.c. Fuse: 0.75A, 3AG (Domestic) or 0.63A, IEC (Export/Australia) – Protects AC Return Battery Type and Back-Up Duration (approximate): 9-Volt Alkaline – 72 hrs. or 9-Volt Ni-MH – 24 hrs. Temperature Limit Range: Operating – 14°F to 140°F (-10°C to 60°C) Storage – -22°F to 149°F (-30°C to 65°C) 37 Warranty The Toro Promise — Limited Three-Year Warranty The Toro Company and its affiliate, Toro Warranty Company, pursuant to an agreement between them, jointly warrants, to the owner, each new piece of equipment (featured in the current catalog at date of installation) against defects in material and workmanship for a period described below, provided they are used for irrigation purposes under manufacturer's recommended specifications. Product failures due to acts of God (i.e., lightning, flooding, etc.) are not covered by this warranty. Neither Toro nor Toro Warranty Company is liable for failure of products not manufactured by them even though such products may be sold or used in conjunction with Toro products. During such warranty period, we will repair or replace, at our option, any part found to be defective. Your remedy is limited solely to the replacement or repair of defective parts. Return the defective part to your local Toro distributor, who may be listed in your telephone directory Yellow Pages under "Irrigation Supplies" or "Sprinkler Systems," or contact The Toro Warranty Company P.O. Box 489, Riverside, California, 92502. Phone (800) 664-4740 for the location of your nearest Toro distributor or outside the U.S., call (909) 688-9221. This warranty does not apply where equipment is used, or installation is performed, in any manner contrary to Toro’s specifications and instructions, nor where equipment is altered or modified. Neither Toro nor Toro Warranty Company is liable for indirect, incidental or consequential damages in connection with the use of equipment, including but not limited to: vegetation loss, the cost of substitute equipment or services required during periods of malfunction or resulting non-use, property damage or personal injury resulting from installer’s actions, whether negligent or otherwise. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. All implied warranties, including those of merchantability and fitness for use, are limited to the duration of this express warranty. Some states do not allow limitations of how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state. The GreenKeeper 212 controller is covered by this warranty for a period of three years from the date of installation. Electromagnetic Compatibility Domestic: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help. The user may find the following booklet prepared by the Federal Communications Commission helpful: “How To Identify and Resolve Radio-TV Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402. Stock No. 004-000-00345-4. International: This is a CISPR 22 Class B product. © 2002 The Toro Company, Irrigation Division, An ISO 9000-Certified Company Form Number 373-0193 Rev. B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Create Date : 2013:05:18 10:15:35Z Keywords : manuals, instruction manuals, user manuals, service manuals, user guides, pdf manuals, owners manuals, installation guides Modify Date : 2014:12:07 14:09:26+08:00 Subject : Search through 700.000 manuals online & and download pdf manuals. Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Description : Search through 700.000 manuals online & and download pdf manuals. Title : ManualsLib - Makes it easy to find manuals online! Creator Tool : pdftk 1.44 - www.pdftk.com Metadata Date : 2014:12:07 14:09:26+08:00 Producer : itext-paulo-155 (itextpdf.sf.net-lowagie.com) Document ID : uuid:fd77d510-a53d-1b47-a36d-11bd130f9f05 Instance ID : uuid:06d2d666-2e48-6240-99d6-a3523f4b3f71 Page Count : 39EXIF Metadata provided by EXIF.tools