Toshiba Dfp 2000A Users Manual DICOM CONFORMANCE STATEMENT
728c1a6f-d17c-4c4e-9dd8-18121880d6f3 Toshiba Portable Media Storage XIDF-037A User Guide |
2014-12-13
: Toshiba Toshiba-Dfp-2000A-Users-Manual-131044 toshiba-dfp-2000a-users-manual-131044 toshiba pdf
Open the PDF directly: View PDF .
Page Count: 23
Download | |
Open PDF In Browser | View PDF |
No. MIIXR0002EAC DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-037A and XIDF-038A or SRS-1000A (MIIXR0002EAC) 2001 No. MIIXR0002EAC IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without written permission. (2) The contents of this manual are subject to change without prior notice and without our legal obligation. C-1 * No. MIIXR0002EAC Table of Contents Page 1 INTRODUCTION................................................................................................................ 1 1.1 1.2 1.3 2 REFERENCES ..................................................................................................... 1 DEFINITIONS ....................................................................................................... 1 ACRONYMS, ABBREVIATIONS AND SYMBOLS ....................................... 2 IMPLEMENTATION MODEL ............................................................................................. 3 2.1 APPLICATION DATA FLOW DIAGRAM ............................................................................... 3 2.2 FUNCTIONAL DEFINITIONS OF AE'S ................................................................................. 3 2.2.1 DICOM Recording ............................................................................................... 3 2.2.2 DICOM Reader .................................................................................................... 4 2.3 SEQUENCING OF REAL WORLD ACTIVITIES ..................................................................... 4 2.3.1 Features............................................................................................................... 4 2.3.1.1 2.3.1.2 2.3.2 2.3.2.1 2.3.2.2 2.4 3 Transfer of X-ray Examination....................................................................................... 4 Review of X-ray Examination ........................................................................................ 4 Operation ............................................................................................................. 5 Transfer of X-ray Examination....................................................................................... 5 Review of X-ray Examination ........................................................................................ 5 FILE META INFORMATION FOR IMPLEMENTATION CLASS AND VERSION ............................. 5 AE SPECIFICATIONS ....................................................................................................... 6 3.1 DICOM RECORDING SPECIFICATION .............................................................................. 6 3.1.1 File Meta Information for the Application Entity ................................................... 6 3.1.2 Real-World Activity .............................................................................................. 6 3.1.2.1 Real-World Activity - Transfer of X-ray Examination ..................................................... 6 3.1.3 Media Storage Application Profile........................................................................ 6 3.1.4 Information Object Definition and DICOMDIR keys ............................................ 6 3.2 DICOM READER SPECIFICATION ................................................................................... 6 3.2.1 File Meta Information for the Application Entity ................................................... 7 3.2.2 Real-World Activity .............................................................................................. 7 3.2.2.1 3.2.3 3.2.4 4 Real-World Activity - Review of X-ray Examination ....................................................... 7 Media Storage Application Profile........................................................................ 7 Information Object Definition and DICOMDIR keys ............................................ 7 AUGMENTED AND PRIVATE APPLICATION PROFILES .............................................. 7 4.1 AUGMENTED APPLICATION PROFILES ............................................................................. 7 4.1.1 AUG-XABC-CD.................................................................................................... 7 4.1.1.1 4.1.1.2 4.1.1.3 4.2 SOP Class Augmentations............................................................................................ 7 Directory Augmentations ............................................................................................... 7 Other Augmentations .................................................................................................... 7 PRIVATE APPLICATION PROFILES.................................................................................... 7 5 EXTENSIONS, SPECIALIZATIONS, AND PRIVATIZATIONS OF SOP CLASSES AND TRANSFER SYNTAXES........................................................................................................... 8 6 CONFIGURATION ............................................................................................................. 8 7 SUPPORT OF EXTENDED CHARACTER SETS............................................................. 8 8 X-RAY ANGIOGRAPHIC INFORMATION OBJECT DEFINITION................................... 9 8.1 ENTITY MODULE DEFINITIONS ........................................................................................ 9 -a- No. MIIXR0002EAC 8.1.1 Media Storage Directory IOD Modules................................................................ 9 8.1.2 Media Storage XA IOD Modules.......................................................................... 9 8.1.3 XA IOD Modules ................................................................................................ 10 8.2 DICOM FILE META INFORMATION ................................................................................ 11 8.2.1 DICOM File Meta Information of Directory IOD ................................................. 11 8.2.2 DICOM File Meta Information of XA IOD........................................................... 11 8.3 BASIC DIRECTORY INFORMATION OBJECT DEFINITIONS ................................................. 11 8.3.1 File-set Identification Module ............................................................................. 11 8.3.2 Directory Information Module............................................................................. 12 8.4 DEFINITION OF SPECIFIC DIRECTORY RECORDS ............................................................ 12 8.4.1 PATIENT keys ................................................................................................... 12 8.4.2 STUDY keys ...................................................................................................... 13 8.4.3 SERIES keys ..................................................................................................... 13 8.4.4 IMAGE keys ....................................................................................................... 14 8.5 XA INFORMATION OBJECT DEFINISIONS........................................................................ 15 8.5.1 Patient Module ................................................................................................... 15 8.5.2 General Study Module ....................................................................................... 15 8.5.3 Patient Study Module......................................................................................... 15 8.5.4 General Series Module ...................................................................................... 16 8.5.5 General Equipment Module ............................................................................... 16 8.5.6 General Image Module ...................................................................................... 16 8.5.7 Image Pixel Module ........................................................................................... 17 8.5.8 Contrast/Bolus Module ...................................................................................... 17 8.5.9 Cine Module....................................................................................................... 17 8.5.10 Multi-frame Module ............................................................................................ 17 8.5.11 X-ray Image Module .......................................................................................... 18 8.5.12 X-ray Acquisition Module ................................................................................... 18 8.5.13 XA Positioner Module ........................................................................................ 19 8.5.14 Curve Module..................................................................................................... 19 8.5.15 VOI LUT Module ................................................................................................ 19 8.5.16 SOP Common Module ....................................................................................... 19 -b- * No. MIIXR0002EAC 1 Introduction This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography Systems. It is intended to provide the reader with the knowledge of how to integrate this product within DICOM compliant equipments. It details the DICOM Service Classes, Information Objects, and Application Profiles which are supported by this product. If the reader is unfamiliar with DICOM, it is recommended that they read the DICOM Specification (referenced below) prior to reading this conformance statement. Also note that this document is formatted according to the DICOM Specification, Part 2: Conformance. 1.1 • References ACR-NEMA Digital Imaging and Communications in Medicine, DICOM V3.0. 1.2 Definitions • Information Object Definition (IOD) - An IOD is a data model which is an abstraction of real-world information. This data model defines the nature and attributes relevant to the class of real-world objects represented. • Service/Object Pair (SOP) Class - A SOP Class is defined by the union of an Information Object Definition and a set of DIMSE Services. A DICOM Application Entity may support one or more SOP Classes. Each SOP Class is uniquely identified by a SOP Class UID. • SOP Instance - A specific occurrence of a Information Object. • Transfer Syntax - The Transfer Syntax is a set of encoding rules that allow DICOM Application Entities to negotiate the encoding techniques (e.g. data element structure, byte ordering, compression) they are able to support. • Unique Identifier (UID) - A Unique Identifier is a globally unique, ISO compliant, ASCII-numeric string. It guarantees uniqueness across multiple countries, sites, vendors and equipment. -1- No. MIIXR0002EAC 1.3 Acronyms, Abbreviations and Symbols • ACC American College of Cardiology • ACR American College of Radiology • ASCII American Standard Code for Information Interchange • AE Application Entity • ANSI American National Standards Institute • AP Application Profile • CEN TC251 Comite Europeen de Normalisation - Technical Committee 251 - Medical Informatics • DICOM Digital Imaging and Communications in Medicine • FSC File-set Creator • FSR File-set Reader • FSU File-set Updater • IOD Information Object Definition • ISO International Standards Organization • JIRA Japan Industries Association of Radiological Systems • NEMA National Electrical Manufacturers Association • RWA Real-World Activity • SOP Service-Object Pair • UID Unique Identifier -2- No. MIIXR0002EAC 2 Implementation Model 2.1 Application Data Flow Diagram Transfer of X-ray Examination DICOM Recording CD-R Medium Review of X-ray Examination DICOM Reader Legend Application Entity Local Real-World Activity File-set Creator (FSC) File-set Reader (FSR) Local Relationship Figure 1 2.2 Functional Definitions of AE's 2.2.1 DICOM Recording The DICOM Recording supports the following tasks: • Builds DICOM XA Information Objects. • Creates a DICOMDIR file that represents the contents of DICOM XA Information Objects to be recorded. • Records DICOM XA Information Objects and DICOMDIR from the local storage to the CD-R media. • Duplicates the File-set of the CD-R media or the local storage onto the blank CD-R media. -3- No. MIIXR0002EAC 2.2.2 DICOM Reader The DICOM Reader supports the following tasks: 2.3 • Reads the DICOMDIR file that represents the contents of the data as recorded. • Displays the ordered list of patient and image identifying information or icon images. • Reads the selected image SOP instance from the CD-R media and displays it on the monitor of the DICOM Reader. • Reads the File-set of the CD-R media and writes it onto the local storage of DICOM Reader. Sequencing of Real World Activities 2.3.1 2.3.1.1 Features Transfer of X-ray Examination Operator requests to transfer images to the local storage after selecting the transferred images from the Patient List or from the Image List. Operator requests to record the images of the local storage onto the CD-R media after transferring all data that are to be recorded. When the size of images exceeds the capacity of a single CD-R, the request of transferring images is canceled. Each CD-R media has a DICOMDIR file that represents the contents of the data as recorded. Operator can request to duplicate the CD-R media from the recorded CD-R media to the blank CD-R media 2.3.1.2 Review of X-ray Examination Operator inserts the CD-R media to be read. Operator requests to display the list of images or the catalog of icon images that are recorded on the CD-R media. Operator selects one image from the list or from the thumbnail images and requests to review the image from the CD-R media. Operator can request to read images from the CD-R media onto the local storage and then operator can request to review the image from the local storage. Operator can request to delete the images on the local storage. The images on the local storage remain after being recorded onto the CD-R media, so operators can display these images from the local storage also. -4- No. MIIXR0002EAC 2.3.2 Operation 2.3.2.1 Transfer of X-ray Examination The operation for manual transfer of X-ray examination is described below: STEP-1: Select the images or the patient to be transferred. STEP-2: Request transfer. STEP-3: Insert the blank CD-R media. STEP-4: Request recording the transferred images onto the CD-R media. 2.3.2.2 Review of X-ray Examination The operation for manual review of X-ray examination is described below: STEP-1: Insert the CD-R media to be review. STEP-2: Select one image from the list or from the thumbnail images. STEP-3: Request forward play, backward play, step by step, or other image processings. 2.4 File Meta Information for Implementation Class and Version • File Meta Information Version 0x0001 • Implementation Class UID 1.2.392.200036.9116.31 • Implementation Version Name TM_XA_DCM_V12 -5- No. MIIXR0002EAC 3 AE Specifications 3.1 DICOM Recording Specification The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage Service, File Format Class and the Media Storage Application Profile. Table 1 Application Profile Identifier Real World Activity Role SC Option Basic Cardiac X-ray Angiographic Studies on CD-R Media STD-XABC-CD Transfer of X-ray Examination FSC Interchange 1024 X-ray Angiographic Studies on CD-R Media STD-XA1K-CD Transfer of X-ray Examination FSC Interchange 3.1.1 File Meta Information for the Application Entity The Application Entity Title is registered into the DICOM File Meta Information header. • 3.1.2 Source Application Entity Title TM_XA_DCM_V12 Real-World Activity 3.1.2.1 Real-World Activity - Transfer of X-ray Examination DICOM Recording AE acts as a FSC when chosen by the operator. This AE writes the SOP instances onto the CD-R media, creates a DICOMDIR and writes it onto the CD-R media. 3.1.3 Media Storage Application Profile DICOM Recording AE uses the Application Profile defined in Table 1. 3.1.4 Information Object Definition and DICOMDIR keys Information Object Definition and DICOMDIR keys are described in Chapter 8. 3.2 DICOM Reader Specification The DICOM Reader AE provides Conformance to the DICOM Media Storage Service, File Format Class and the Media Storage Application Profile. Table 2 Application Profile Identifier Real World Activity Role SC Option Basic Cardiac X-ray Angiographic Studies on CD-R Media STD-XABC-CD Review of X-ray Examination FSR Interchange Extended Cardiac X-ray Angiographic Studies on CD-R Media AUG-XABC-CD Review of X-ray Examination FSR Interchange -6- No. MIIXR0002EAC 3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relevant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator. This AE reads the DICOMDIR from the CD-R media and reads the SOP instances from the CD-R media. 3.2.3 Media Storage Application Profile DICOM Reader AE uses the Application Profile defined in Table 2. 3.2.4 Information Object Definition and DICOMDIR keys Information Object Definition and DICOMDIR keys are described in Chapter 8. 4 Augmented and Private Application Profiles 4.1 Augmented Application Profiles DICOM Reader AE supports Augmented Application Profile: AUG-XABC-CD. This is a extension of the standard Application Profile: STD-XABC-CD. 4.1.1 AUG-XABC-CD 4.1.1.1 SOP Class Augmentations None 4.1.1.2 Directory Augmentations None 4.1.1.3 Other Augmentations The following attributes used within the X-ray Angiographic Image files have the specified values. Table 3 Attribute Name 4.2 Tag Value Modality (0008, 0060) XA Rows (0028, 0010) 1024 Columns (0028, 0011) 1024 Bits Allocated (0028, 0100) 8 Bits Stored (0028, 0101) 8 Private Application Profiles Not applicable to this product. -7- No. MIIXR0002EAC 5 Extensions, Specializations, and Privatizations of SOP Classes and Transfer Syntaxes Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set. Note: Settings and changes are performed by Toshiba Service Personnel at the time of installation of the Digital Fluorography System. 7 Support of Extended Character Sets This product supports the following character sets: Table 4 • ISO-IR 6 (default) Basic G0 Set -8- No. MIIXR0002EAC 8 X-Ray Angiographic Information Object Definition 8.1 Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Table 5 Object Module / key DICOM File Meta Information Reference Usage1 8.2.1 M Basic Directory Information Object Definition File-set Identification Module 8.3.1 M Directory Information Module 8.3.2 U Definition of Specific Directory Records PATIENT keys 8.4.1 M STUDY keys 8.4.2 M SERIES keys 8.4.3 M IMAGE keys 8.4.4 M Reference Usage1 8.2.2 M 8.1.3 M 1 8.1.2 M=Mandatory, C=Conditional, U=User option Media Storage XA IOD Modules Table 6 Object Module / key DICOM File Meta Information XA Information Object Definition 1 XA IOD Modules M=Mandatory, C=Conditional, U=User option -9- No. MIIXR0002EAC 8.1.3 XA IOD Modules Table 7 Information Entity Module Reference Usage1 Patient Patient Module 8.5.1 M Study General Study Module 8.5.2 M Study Patient Study Module 8.5.3 U Series General Series Module 8.5.4 M Equipment General Equipment Module 8.5.5 M Image General Image Module 8.5.6 M Image Image Pixel Module 8.5.7 M Image Contrast/bolus Module 8.5.8 C Image Cine Module 8.5.9 C Image Multi-frame Module 8.5.10 C Image Frame Pointers Module Not Used U Image Mask Module Not Used C Image Display Shutter Module Not Used U Image Device Module Not Used U Image Therapy Module Not Used U Image X-ray Image Module 8.5.11 M Image X-ray Acquisition Module 8.5.12 M Image X-ray Collimator Module Not Used U Image X-ray Table Module Not Used C Image XA Positioner Module 8.5.13 M Image Overlay Plane Module Not Used U Image Multi-Frame Overlay Module Not Used C Image Curve Module 8.5.14 C (Note) Image Modality LUT Module Not Used C/U Image VOI LUT Module 8.5.15 U Image SOP Common Module 8.5.16 M 1 M=Mandatory, C=Conditional, U=User option Note : Always set when ECG data is available - 10 - No. MIIXR0002EAC 8.2 DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Table 8 Attribute Name Tag Type File Preamble No Tag 1 Always set DICOM Prefix No Tag 1 Always set ("DICM") Group Length (0002, 0000) 1 Always set File Meta Information Version (0002, 0001) 1 Always set (0x0001) Media Storage SOP Class UID (0002, 0002) 1 Always set ("1.2.840.10008.1.3.10") Media Storage SOP Instance UID (0002, 0003) 1 Always set Transfer Syntax UID (0002, 0010) 1 Always set ("1.2.840.10008.1.2.1") Implementation Class UID (0002, 0012) 1 Always set 8.2.2 Attribute Description DICOM File Meta Information of XA IOD Table 9 Attribute Name Tag Type File Preamble No Tag 1 Always set DICOM Prefix No Tag 1 Always set ("DICM") Group Length (0002, 0000) 1 Always set File Meta Information Version (0002, 0001) 1 Always set (0x0001) Media Storage SOP Class UID (0002, 0002) 1 Always set ("1.2.840.10008.5.1.4.1.1.12.1") Media Storage SOP Instance UID (0002, 0003) 1 Always set Transfer Syntax UID (0002, 0010) 1 Always set ("1.2.840.10008.1.2.4.70") Implementation Class UID (0002, 0012) 1 Always set Implementation Version Name (0002, 0013) 3 Always set 8.3 8.3.1 Attribute Description Basic Directory Information Object Definitions File-set Identification Module Table 10 Attribute Name File-set ID Tag Type (0004, 1130) 2 - 11 - Attribute Description Always set No. MIIXR0002EAC 8.3.2 Directory Information Module Table 11 Attribute Name Tag Type Offset of the First Directory Record of the Root Directory Entity (0004, 1200) 1 Always set Offset of the Last Directory Record of the Root Directory Entity (0004, 1202) 1 Always set File-set Consistency Flag (0004, 1212) 1 Always set Directory Record Sequence (0004, 1220) 2 Always set >Offset of the Next Directory Record (0004, 1400) 1C Always set when condition is met >Record In-use Flag (0004, 1410) 1C Always set when condition is met >Offset of Referenced Lower-Level Directory Entity (0004, 1420) 1C Always set when condition is met >Directory Record Type (0004, 1430) 1C Always set when condition is met >Referenced File ID (0004, 1500) 1C Always set when condition is met >Referenced SOP Class UID in File (0004, 1510) 1C Always set when condition is met >Referenced SOP Instance UID in File (0004, 1511) 1C Always set when condition is met >Referenced Transfer Syntax UID in File (0004, 1512) 1C Always set when condition is met 8.4 Attribute Description Definition of Specific Directory Records 8.4.1 PATIENT keys Table 12 Attribute Name Tag Type Patient's Name (0010, 0010) 2 Always set except for urgent patient Patient ID (0010, 0020) 1 Always set Patient's Birth Date (0010, 0030) 2 Length=0 when no entry is made Patient's Sex (0010, 0040) 2 Always set - 12 - Attribute Description No. MIIXR0002EAC 8.4.2 STUDY keys Table 13 Attribute Name Tag Type Study Date (0008, 0020) 1 Always set Study Time (0008, 0030) 1 Always set Study Description (0008, 1030) 2 Length=0 when no entry is made Study Instance UID (0020, 000D) 1C Always set Study ID (0020, 0010) 1 Always set Accession Number (0008, 0050) 2 Length=0 when no entry is made 8.4.3 Attribute Description SERIES keys Table 14 Attribute Name Tag Type Modality (0008, 0060) 1 Always set ("XA") Series Instance UID (0020, 000E) 1 Always set Series Number (0020, 0011) 1 Always set Institution Name (0008, 0080) 2 Always set Institution Address (0008, 0081) 2 Always set Performing Physician's Name (0008, 1050) 2 Length=0 when no entry is made - 13 - Attribute Description No. MIIXR0002EAC 8.4.4 IMAGE keys Table 15 Attribute Name Tag Type Instance Number (0020, 0013) 1 Always set Image Type (0008, 0008) 1 Always set Image Date (0008, 0023) 3 Always set Image Time (0008, 0033) 3 Always set Positioner Primary Angle (0018, 1510) 3 Always set [degree] Positioner Secondary Angle (0018, 1511) 3 Always set [degree] Image Comments (0020, 4000) 3 Length=0 when no entry is made Number of Frames (0028, 0008) 3 Always set Calibration Image (0050, 0004) 2 Always set Icon Image Sequence (0088, 0200) 1 Always set >Samples per Pixel (0028, 0002) 1 Always set (0x0001) >Photometric Interpretation (0028, 0004) 1 Always set ("MONOCHROME2") >Rows (0028, 0010) 1 Always set (0x0100) >Columns (0028, 0011) 1 Always set (0x0100) >Bits Allocated (0028, 0100) 1 Always set (0x0008) >Bits Stored (0028, 0101) 1 Always set (0x0008) >High Bit (0028, 0102) 1 Always set (0x0007) >Pixel Representation (0028, 0103) 1 Always set (0x0000) >Pixel Data (7FE0, 0010) 1 Always set - 14 - Attribute Description No. MIIXR0002EAC 8.5 XA Information Object Definisions 8.5.1 Patient Module Table 16 Attribute Name Tag Type Patient's Name (0010, 0010) 2 Always set except for urgent patient Patient ID (0010, 0020) 2 Always set Patient's Birth Date (0010, 0030) 2 Length=0 when no entry is made Patient's Sex (0010, 0040) 2 Always set Patient Comments (0010, 4000) 3 Length=0 when no entry is made 8.5.2 Attribute Description General Study Module Table 17 Attribute Name Tag Type Study Instance UID (0020, 000D) 1 Always set Study Date (0008, 0020) 2 Always set Study Time (0008, 0030) 2 Always set Referring Physician's Name (0008, 0090) 2 Length=0 when no entry is made Study ID (0020, 0010) 2 Always set Accession Number (0008, 0050) 2 Length=0 when no entry is made Study Description (0008, 1030) 3 Length=0 when no entry is made 8.5.3 Attribute Description Patient Study Module Table 18 Attribute Name Tag Type Patient's Size (0010, 1020) 3 Length=0 when no entry is made Patient's Weight (0010, 1030) 3 Length=0 when no entry is made - 15 - Attribute Description No. MIIXR0002EAC 8.5.4 General Series Module Table 19 Attribute Name Tag Type Modality (0008, 0060) 1 Always set ("XA") Series Instance UID (0020, 000E) 1 Always set Series Number (0020, 0011) 2 Always set Series Date (0008, 0021) 3 Always set Series Time (0008, 0031) 3 Always set Performing Physician's Name (0008, 1050) 3 Length=0 when no entry is made Series Description (0008, 103E) 3 Always set 8.5.5 Attribute Description General Equipment Module Table 20 Attribute Name Tag Type Manufacturer (0008, 0070) 2 Always set Institution Name (0008, 0080) 3 Always set Institution Address (0008, 0081) 3 Always set Station Name (0008, 1010) 3 Always set Manufacturer's Model Name (0008, 1090) 3 Always set Device Serial Number (0018, 1000) 3 Always set Software Versions (0018, 1020) 3 Always set 8.5.6 Attribute Description General Image Module Table 21 Attribute Name Tag Type Image Number (0020, 0013) 2 Patient Orientation (0020, 0020) 2C Always Length=0 Image Date (0008, 0023) 2C Always set Image Time (0008, 0033) 2C Always set Image Type (0008, 0008) 3 Always set Acquisition Date (0008, 0022) 3 Always set Acquisition Time (0008, 0032) 3 Always set Image Comments (0020, 4000) 3 Length=0 when no entry is made - 16 - Attribute Description Always set No. MIIXR0002EAC 8.5.7 Image Pixel Module Table 22 Attribute Name Tag Type Samples per Pixel (0028, 0002) 1 Always set (0x0001) Photometric Interpretation (0028, 0004) 1 Always set ("MONOCHROME2") Rows (0028, 0010) 1 Always set (0x0400 or 0x0200) Columns (0028, 0011) 1 Always set (0x0400 or 0x0200) Bits Allocated (0028, 0100) 1 Always set (0x0008) Bits Stored (0028, 0101) 1 Always set (0x0008) High Bit (0028, 0102) 1 Always set (0x0007) Pixel Representation (0028, 0103) 1 Always set Pixel Data (7FE0, 0010) 1 Always set 8.5.8 Attribute Description Contrast/Bolus Module Table 23 Attribute Name Tag Type Contrast/Bolus Agent (0018, 0010) 2 Length=0 when no entry is made Contrast/Bolus Route (0018, 1040) 3 Length=0 when no entry is made Contrast/Bolus Volume (0018, 1041) 3 Length=0 when no entry is made Contrast Flow Rate(s) (0018, 1046) 3 Length=0 when no entry is made 8.5.9 Attribute Description Cine Module Table 24 Attribute Name Frame Time 8.5.10 Tag Type (0018, 1063) 1C Attribute Description Always set Multi-frame Module Table 25 Attribute Name Tag Type Number of Frames (0028, 0008) 1 Always set Frame Increment Pointer (0028, 0009) 1 Always set (0x00181063) - 17 - Attribute Description No. MIIXR0002EAC 8.5.11 X-ray Image Module Table 26 Attribute Name Tag Type Frame Increment Pointer (0028, 0009) 1C Image Type (0008, 0008) 1 Always set Pixel Intensity Relationship (0028, 1040) 1 Always set ("DISP" or "LIN") Samples per Pixel (0028, 0002) 1 Always set (0x0001) Photometric Interpretation (0028, 0004) 1 Always set ("MONOCHROME2") Bits Allocated (0028, 0100) 1 Always set (0x0008) Bits Stored (0028, 0101) 1 Always set (0x0008) High Bit (0028, 0102) 1 Always set (0x0007) Pixel Representation (0028, 0103) 1 Always set Reference Image Sequence (0008, 1140) 1C Not set when Image type(0008,0008) Value 3 is "SINGLE PLANE" >Reference SOP Class UID (0008, 1150) 1C Always set when Reference Image Sequence is present >Reference SOP Instance UID (0008, 1155) 1C Always set when Reference Image Sequence is present 8.5.12 Attribute Description Always set (0x00181063) X-ray Acquisition Module Table 27 Attribute Name Tag Type KVP (0018, 0060) 2 Always set [kV] Radiation Setting (0018, 1155) 1 Always set X-ray Tube Current (0018, 1151) 2C Always set [mA] Exposure Time (0018, 1150) 2C Always set [msec] Average Pulse Width (0018, 1154) 3 Always set [msec] Intensifier Size (0018, 1162) 3 Always set [mm] Field of View Shape (0018, 1147) 3 Always set("ROUND ") Field of View Dimension(s) (0018, 1149) 3 Always set [mm] Imager Pixel Spacing (0018, 1164) 3 Always set [mm] - 18 - Attribute Description No. MIIXR0002EAC 8.5.13 XA Positioner Module Table 28 Attribute Name Tag Type Attribute Description Distance Source to Detector (0018, 1110) 3 Always set [mm] Estimated Radiographic Magnification (0018,1114) 3 Always set Positioner Motion (0018, 1500) 2C Positioner Primary Angle (0018, 1510) 2 Always set [degree] Positioner Secondary Angle (0018, 1511) 2 Always set [degree] Factor 8.5.14 Always set ("STATIC") Curve Module Table 29 Attribute Name Tag Type Attribute Description Curve Dimensions (5000, 0005) 1 Always set Number of Points (5000, 0010) 1 Always set Type of Data (5000, 0020) 1 Always set Axis Units (5000, 0030) 3 Always set Data Value Representation (5000, 0103) 1 Always set Curve Data Descriptor (5000, 0110) 1C Always set Coordinate Start Value (5000, 0112) 1C Always set Coordinate Step Value (5000, 0114) 1C Always set Curve Data (5000, 3000) 1 Always set Note : This module is set only if ECG data is available. 8.5.15 VOI LUT Module Table 30 Attribute Name Tag Type Window Center (0028, 1050) 3 Always set Window Width (0028, 1051) 1C Always set 8.5.16 Attribute Description SOP Common Module Table 31 Attribute Name Tag Type SOP Class UID (0008, 0016) 1 Always set SOP Instance UID (0008, 0018) 1 Always set - 19 - Attribute Description E
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2001:12:20 13:11:46+09:00 Create Date : 2001:12:20 12:01:00+09:00 Page Count : 23 Creation Date : 2001:12:20 12:01:00+09:00 Mod Date : 2001:12:20 13:11:46+09:00 Producer : Acrobat Distiller 5.0 (Windows) Author : Naoki Yamada Metadata Date : 2001:12:20 13:11:46+09:00 Creator : Naoki Yamada Title : DICOM CONFORMANCE STATEMENT Page Mode : UseNone Tagged PDF : YesEXIF Metadata provided by EXIF.tools