Trane TWE030c Insight ™ Ducted Air Handler Cooling Only Split System Conditioning , 30 To 50 MBh, PDF Product Catalog (TWE5 PRC000 EN) User Manual The Bf43665d 9d07 4308 Ba6c 008c94a89472
User Manual: Trane TWE030c to the manual
Open the PDF directly: View PDF .
Page Count: 30
Download | ![]() |
Open PDF In Browser | View PDF |
Insight™ Ducted Air Handler Cooling Only Split System Air Conditioning 30 to 50 MBh - 50 Hz Air Handler Models TWE030C TWE040C TWE050C Condensing Models TTB524-536C TTA030-060C TWE5-PRC000-EN April 1999 Table of Contents Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 System Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Model Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Product Data TWE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 TTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 TTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Performance Data TTB/TWE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 TTA/TWE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Supplementary Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 System Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 ©American Standard Inc. 1999 2 TWE5-PRC000-EN Features and Benefits AIR HANDLING UNITS New Features Features • Ships horizontal • Six way convertibility- horizontal (left and right), upflow, downflow (front and rear access) • Electrical, refrigerant, condensate and blower access convertible to either side • Corrosion resistant galvanized steel with attractive finish TWE • Internally enhanced finned coil tubes • Direct drive motor • Standard filters • Multi-speed blower • 220 volt primary and 24 volt secondary transformer • Improved filter access and latch Eliminate current T-bar and shipping bracket. • Provision for 1 1 /8” thick field supplied electrostatic filter • Reversible Duct Flanges - Fits up to 1 1/2” duct board • Improve controls access with control box mounted next to blower. • 40 VA transformer with 5 amp automotive style fuse on 3 tons and less • 5 Amp automotive style fuse replaces Bussman “red cap” fuse on 3.5 to 5 ton models • Blower mounting brackets improved - Front access to screw with power driver • Insulated cabinet Improved bottom carton cushioning • External access to heater circuit breakers • • 1” thick foil faced insulation for all • Start kits are not required models • Built-in indoor fan delay function for increased efficiency. No kit required. TTB TTA CONDENSING UNITS Features: Benefits: • Vertical Air Discharge • Flexibility in application • High Efficiency TRANE Climatuff ® Compressor • Powder Paint finish • Brazed or flare connections TWE5-PRC000-EN 3 • Quality and reliability • Uniform covering for a smooth, attractive and corrosion-resistant finish System Performance Outdoor Unit Indoor Unit Ducted Air Handlers TTB524CA00A TWE030CA40B TTB530CA00A TWE030CA40C TTB530CA00A TWE040CA40C TTB536CA00A TWE040CA40C TTA030CD00A† TWE030CA40B TTA030CD00A† TWE040CA40C TTA040CD00A† TWE040CA40C TTA040CD00A† TWE050CA50D TTA050CD00A† TWE050CA50D TTA060CD00A† TWE050CA50D *MBh 95º F Indoor kW CFM CMH 25.8 30.8 32.4 39.0 30.5 32.5 41.0 43.9 52.7 62.8 6.9 8.4 9.5 10.1 8.9 9.4 12.0 12.8 15.4 18.4 1520 1689 2038 2038 1689 1900 2238 2703 3040 3040 900 1000 1200 1200 1000 1125 1325 1600 1800 1800 †Outdoor: 380-415/50/3, Indoor: 220-240/50/1 *Cooling capacity is based on 94ºF outside ambient, 80ºF DB/67ºF WB air on coil. 4 TWE5-PRC000-EN Model Nomenclature TW E 0 30 C A 4 0 A 0 1,2 3 4 5,6 7 8 9 10 11 12 Digit 1,2 - Product Type TW = Split System Component Heat Pump Compatible Digit 3 - Airflow Configuration E = Convertible Digit 4 - Refrigerant Connections 0 = Brazed 5 = Flare Digit 7 C = Development Sequence Digit 8 - Voltage A = 220/1/50 Digit 9 - Refrigerant Flow Control 4 = Accutron Flow Control/ Check Valve 5 = Bleed TXV Digit 10 - Not Used Digits 5,6 - Nominal Capacity 30 = 30 MBh 40 = 40 MBh 50 = 50 MBh Digit 11 - Minor Design Change Digit 12 - Service Digit TWE5-PRC000-EN 5 Product Data Table 1 — TWE Product Specifications Model Power Conn.— Volts/Ph/Hz Indoor Coil - Type Rows Fins per inch (Fins per 25.4mm) Face Area ft2-(m2) Tube Size in. (mm) Refrigerant Control Drain Conn. Size in. (mm) Duct Connections Indoor Fan - Type No. Used Diameter in. (mm) Width in. (mm) Type Drive - No. Speeds Airflow (High) CFM @ 0.0 in. w.g. CMH @ 0.0 mm w.g. No. Motors - HP Motor RPM Volts/Ph/Hz F.L. Amps L.R. Amps Filters Vertical Applications Filter Furnished Type Furnished No.-Size-Thickness Horizontal Applications Filter Furnished Type Recommended No.-Size-Thickness Refrigerant Line Size Line Size ID Gas in. (mm) Line Size ID Liquid in. (mm) Dimensions (H x W x D) Crated - in. - (mm) Uncrated - in. - (mm) Weight Ibs. (kg) Shipping Net TWE030CA40B TWE040CA40C TWE050CA50D 220/1/50 220/1/50 220/1/50 Plate Fin Plate Fin Plate Fin 3 3 3 14 14 14 3.21 (.30) 5.04 (.47) 6.19 (.58) 3 3 3 /8 (9.52) /8 (9.52) /8 (9.52) FCCV FCCV FCCV 3 3 3 /4 NPT /4 NPT /4 NPT —————————— SEE OUTLINE DRAWING ——————————— Centrifugal Centrifugal Centrifugal 1 1 1 10.0 (254.0) 10.0 (254.0) 11.0 (279.4) 8.0 (203.2) 10.0 (254.0) 10.0 (254.0) Direct - 3 Direct - 3 Direct - 3 —————————— SEE FAN PERFORMANCE TABLE —————————— —————————— SEE FAN PERFORMANCE TABLE —————————— 1 - 1/3 1 - 3/4 1 - 1/3 1000 900 900 220/1/50 220/1/50 220/1/50 2.6 2.1 4.5 3.3 4.2 10.1 Yes Throwaway 1 - 20 x 20 - 1 No Yes Throwaway 1 - 20 x 20 - 1 Yes High Velocity 1 - 2 2 x 20 - 1 No No —————————— SEE NOTE BELOW —————————— —————————— SEE NOTE BELOW —————————— 7 / (22.23) / (9.52) 11/8 (28.56) 3 /8 (9.52) 11/8 (28.56) 3 /8 (9.52) 44.5 x 24.0 x 23.5 (1130 x 610 x 597) 43.0 x 21.5 x 21.0 (1092 x 546 x 533) 53.25 x 26.0 x 23.5 (1353 x 660 x 597) 52.0 x 23.5 x 21.0 (1321 x 597x 533) 59.5 x 26.0 x 23.5 (1511 x 660 x 597) 58.0 x 23.5 x 21.0 (1473 x 597 x 533) 125 (56.7) 115 (52.2) 165 (74.8) 150 (68.0) 198 (898) 183 (83.0) 8 3 8 Minimum filter size for horizontal applications based on airflow selection and calculated as follows: Low Velocity Filter: Face Area (ft2) = CFM/300 High Velocity Filter: Face Area (ft2) = CFM/500 6 TWE5-PRC000-EN Product Data Table 2 — TTB5 Product Specifications1,2 Model Power Conn. — Volts/Ph/Hz Min. Brch. Cir. Ampacity3 Br. Cir. Max. (Amps) Prot. Rtg. Recmd. (Amps) Compressor Type No. Used - No. Speeds Volts/Ph/Hz R.L. Amps - L.R. Amps Voltage Utilization Range Brch. Cir. Selec. Cur. Amps Outdoor Fan - Type Dia. - in. (mm) - No. Used Type Drive - No. Speeds CFM @ 0.0 in. w.g.4 CMH @ 0.0 mm w.g. No. Motors Motor HP (W) Motor Speed RPM Volts/Ph/Hz F.L. Amps Outdoor Coil - Type Rows - Fins/in. (Fins/mm) Face Area - ft2 (m2) Tube Size - in. (mm) Refrigerant R-225 - lbs. (kg) Factory Supplied Line Size - O.D. Gas6 - in. (mm) Line Size - O.D. Liq.6 - in. (mm) Dimensions (H x W x D) Crated - in. - (mm) Uncrated Weight lbs. (kg) Shipping Net TTB524CA00A 200-230/1/50 19 30 30 Climatuff® Reciprocating 1—1 200-230/1/50 13.9 — 60 180-253 13.9 Propeller 18 (457) — 1 Direct — 1 1925 908 1 1 /6 (124) 1100 200-230/1/50 1.30 Spine Fin™ 1 — 24 (1) 10.96 (1.02) 3 /8 (10) TTB530CA00A 200-230/1/50 20 30 30 Climatuff® Reciprocating 1—1 200-230/1/50 13.9 — 79 180-253 14.9 Propeller 18 (457) — 1 Direct — 1 2225 1050 1 1 /6 (124) 1100 200-230/1/50 1.30 Spine Fin™ 1 — 24 (1) 14.93 (1.39) 3 /8 (10) 4 lbs, 15 oz. (2.24) Yes 3 /4 (20) 5 /16 (8) 6 lbs, 11 oz. (3.03) Yes 3 /4 (20) 5 /16 (8) 263/8 x 267/8 x 267/8 (670 x 683 x 683) See Outline Dwg. 333/8 x 267/8 x 267/8 (848 x 683 x 683) See Outline Dwg. 176 (79.8) 166 (75.3) 184 (83.5) 174 (78.9) Notes: 1 Rated in accordance with ARI Standard 210/240. 2 Rated in accordance with ARI Standard 270. 3 Calculated in accordance with National Electric Code. Suitable for use with HACR circuit breakers or fuses. 4 Standard air — dry coil — outdoor. 5 This value approximate. For more precise value see unit nameplate and service instructions. 6 Max. linear length 80 ft.; max. lift — suction 60 ft.; max. lift — liquid 60 ft. Max. length of precharged tubing 50 ft. For greater length refer to Refrigerant Piping Manual Pub. No. 32-3009. TWE5-PRC000-EN 7 Product Data Table 3 — TTB5 Product Specifications1,2 Model Power Conn. - Volts/Ph/Hz Min. Brch. Cir. Ampacity3 Br. Cir. Max. (Amps) Prot. Rtg. Recmd. (Amps) Compressor Type No. Used - No. Speeds Volts/Ph/Hz R.L. Amps - L.R. Amps Voltage Utilization Range Brch. Cir. Selec. Cur. Amps Outdoor Fan - Type Dia. in. (mm) - No. Used Type Drive - No. Speeds CFM @ 0.0 in. w.g.4 CMH @ 0.0 mm w.g. No. Motors Motors HP (W) Motor Speed RPM Volts/Ph/Hz F.L. Amps Outdoor Coil - Type Rows - Fins/in. (Fins/mm) Face Area - ft2 (m2) Tube Size - in. (mm) Refrigerant R-225 - lbs. (kg) Factory Supplied Line Size - O.D. Gas6 - in. (mm) Line Size - O.D. Liq.6 - in. (mm) Dimensions (H x W x D) Crated - in. - (mm) Uncrated Weight lbs. (kg) Shipping Net TTB536CA00A 200-230/1/50 24 40 40 Climatuff® Reciprocating 1—1 200-230/1/50 17.6 — 95 180-253 17.6 Propeller 18 (457) — 1 Direct — 1 2225 1050 1 1 /6 (124) 1100 200-230/1/50 1.30 Spine Fin™ 1 — 24 (1) 14.93 (1.39) 3 /8 (10) 6 lbs, 11 oz. (3.03) Yes 3 /4 (20) 5 /16 (8) 333/8 x 267/8 x 267/8 (848 x 683 x 683) See Outline Dwg. 203 (92.1) 193 (87.5) Notes: 1 Rated in accordance with ARI Standard 210/240. 2 Rated in accordance with ARI Standard 270. 3 Calculated in accordance with National Electric Code. Suitable for use with HACR circuit breakers or fuses. 4 Standard air — dry coil — outdoor. 5 This value approximate. For more precise value see unit nameplate and service instructions. 6 Max. linear length 80 ft.; max. lift — suction 60 ft.; max. lift — liquid 60 ft. Max. length of precharged tubing 50 ft. For greater length refer to Refrigerant Piping Manual Pub. No. 32-3009. 8 TWE5-PRC000-EN Product Data Table 4 — TTA Product Specifications Model Power Conn. - Volts/Ph/Hz Fuse Size - max. amps Compressor - Type No. Used - No. Speeds Volts/Ph/Hz F.L. Amps1 L.R. Amps Outdoor Fan - Type No. Used Diameter in. (mm) Type Drive - No. Speeds CFM @ 0.0 in. w.g. CMH @ 0.0 mm w.g. No. Motors - HP Motor Speed (RPM) Volts/Ph/Hz F.L. Amps Outdoor Coil - Type No. Rows - Fins/in. Face Area ft2 (m2) Tube Size in. (mm) Refrigerant R-222 - lbs. (kg) Line Size - OD Gas in. (mm) Line Size - OD Liq. in. (mm) Dimensions (H x W x D) Crated - in. - (mm) Uncrated - in. - (mm) Weight- lbs. (kg) Shipping Net TTA030CD00A TTA040CD00A TTA050CD00A TTA060CD00A 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Per Local Codes Per Local Codes Per Local Codes Per Local Codes —————————— Climatuff® Reciprocating —————————— 1-1 1-1 1-1 1-1 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 5.0 7.0 9.0 10.6 51.0 51.0 71.0 64.0 Propeller Propeller Propeller Propeller 1 1 1 1 18 (457) 18 (457) 22 (559) 26 (660) Direct-1 Direct-1 Direct-1 Direct-1 1815 1845 2225 4250 3083 3134 3780 7220 1 - 1/4 1 - 1/3 1 - 1/3 1 - 1/4 1 (900) 1 (900) 1 (690) 1 (690) 400/1/50 400/1/50 400/1/50 400/1/50 0.80 0.80 1.00 1.70 Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ 1 - 24 1 - 24 1 - 24 1 - 24 12.22 (1.14) 16.84 (1.57) 25.50 (2.37) 35.39 (3.29) 3 3 3 3 /8 (9.52) /8 (9.52) /8 (9.52) /8 (9.52) 5 Ibs, 12 oz. (2.61) 7 /8 (22.3) 3 /8 (9.52) 7 Ibs, 2 oz. (3.23) 11/8 (28.6) 3 /8 (9.52) 9 Ibs, 2 oz. (4.14) 11/8 (28.6) 3 /8 (9.52) 13 Ibs, 0 oz. (5.90) 11/8 (28.6) 3 /8 (9.52) 25.0 x 30.0 x 26.5 (635 x 762 x 673) 24.3 x 28.3 x 24.6 (617 x 719 x 625) 33.3 x 30.0 x 26.5 (846 x 762 x 673) 32.8 x 28.3 x 24.6 (833 x 719 x 625) 41.3 x 34.8 x 31.3 (1049 x 884 x 795) 40.6 x 32.9 x 28.8 (1031 x 836 x 732) 45.5 x 41.0 x 37.0 (1156 x 1041 x 940) 44.8 x 38.9 x 34.8 (1138 x 988 x 884) 190.0 (86.2) 181.0 (82.1) 211.0 (95.7) 200.0 (90.7) 254.0 (115.2) 239.0 (108.4) 333.0 (151.0) 314.0 (142.0) 1 At ARI system rating conditions of 80° F-DB/67° F-WB indoor & 95° F-DB outdoor. Rated for 25 feet (7.5 meters) of evacuated refrigerant piping. 2 TWE5-PRC000-EN 9 Performance Data Cooling TTB524CA00A WITH TWE030CA40B AT 900 CFM GROSS CAPACITY IN BTU/H x 1000 O.D. D.B. 85 90 95 100 105 115 I.D. TOTAL W.B. CAP. 59 22.9 63 24.7 67 26.6 71 28.6 59 22.6 63 24.4 67 26.2 71 28.1 59 22.3 63 24.0 67 25.8 71 27.7 59 21.5 63 23.2 67 24.9 71 26.7 59 20.8 63 22.4 67 24.0 71 25.7 59 19.3 63 20.7 67 22.2 71 23.8 English Units TTB530CA00A WITH TWE030CA40B AT 1000 CFM GROSS CAPACITY IN BTU/H x 1000 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 20.9 22.6 23.4* 24.0* 24.6* 1.90 17.6 19.3 21.0 22.7 24.4 1.97 13.9 15.6 17.3 19.0 20.7 2.04 10.2 11.9 13.6 15.3 17.0 2.11 20.7 22.4 23.1* 23.8* 24.3* 2.01 17.4 19.1 20.8 22.5 24.2 2.07 13.8 15.5 17.2 18.9 20.6 2.14 10.0 11.7 13.4 15.1 16.8 2.21 20.6 22.3* 22.9* 23.5* 24.0* 2.11 17.3 19.0 20.7 22.4 24.0* 2.18 13.6 15.3 17.0 18.7 20.4 2.25 9.9 11.6 13.3 15.0 16.7 2.32 20.2 21.7* 22.3* 22.8* 23.4* 2.20 16.9 18.6 20.3 22.0 23.4* 2.26 13.2 14.9 16.6 18.4 20.1 2.33 9.5 11.2 12.9 14.6 16.3 2.40 19.9 21.1* 21.6* 22.2* 22.7* 2.29 16.6 18.3 20.0 21.7 22.7* 2.35 12.9 14.6 16.3 18.0 19.7 2.41 9.1 10.8 12.5 14.2 15.9 2.48 19.2 19.8* 20.3* 20.8* 21.3* 2.47 15.9 17.6 19.3 20.8* 21.3* 2.53 12.2 13.9 15.6 17.3 19.0 2.58 8.4 10.1 11.8 13.5 15.2 2.64 O.D. D.B. 85 90 95 100 105 115 I.D. TOTAL W.B. CAP. 59 27.4 63 29.5 67 31.6 71 33.9 59 27.1 63 29.1 67 31.2 71 33.4 59 26.7 63 28.7 67 30.8 71 33.0 59 25.8 63 27.8 67 29.8 71 31.9 59 25.0 63 26.8 67 28.8 71 30.8 59 23.2 63 25.0 67 26.7 71 28.6 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 24.2 26.1 27.6* 28.3* 29.0* 2.05 20.5 22.4 24.3 26.2 28.1 2.12 16.5 18.4 20.2 22.1 24.0 2.20 12.3 14.2 16.1 18.0 19.8 2.28 24.1 25.9 27.3* 28.0* 28.7* 2.15 20.4 22.3 24.1 26.0 27.9 2.23 16.3 18.2 20.1 21.9 23.8 2.31 12.1 14.0 15.9 17.8 19.7 2.39 23.9 25.8 27.0* 27.7* 28.4* 2.25 20.2 22.1 24.0 25.9 27.7 2.33 16.1 18.0 19.9 21.8 23.7 2.41 11.9 13.8 15.7 17.6 19.5 2.49 23.5 25.4 26.3* 27.0* 27.6* 2.34 19.8 21.7 23.6 25.4 27.3 2.42 15.7 17.6 19.5 21.4 23.2 2.50 11.5 13.4 15.3 17.2 19.1 2.58 23.1 25.0 25.6* 26.3* 26.6* 2.43 19.4 21.3 23.1 25.0 26.9* 2.51 15.3 17.2 19.1 20.9 22.8 2.59 11.1 13.0 14.9 16.8 18.6 2.67 22.3 23.5* 24.2* 24.7* 25.3* 2.62 18.6 20.4 22.3 24.2 25.3* 2.69 14.5 16.3 18.2 20.1 22.0 2.77 10.3 12.2 14.0 15.9 17.8 2.84 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW AIRFLOW TOTAL CAP. COMPR. KW 775 X0.98 X0.99 1025 X1.01 X1.01 AIRFLOW SENS. CAP. VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 25800 BTUH AIRFLOW = 900 CFM COMPRESSOR POWER = 2245 WATTS I.D. FAN POWER = 425 WATTS O.D. FAN POWER = 165 WATTS S.E.E.R. = 8.71 BTUH/WATT E.E.R. = 9.10 BTUH/WATT 775 X0.94 1025 X1.06 1000 X1.00 X1.00 1000 X1.00 X1.00 AIRFLOW SENS. CAP. 1000 X1.00 1000 X1.00 VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 30800 BTUH AIRFLOW = 1000 CFM COMPRESSOR POWER = 2410 WATTS I.D. FAN POWER = 440 WATTS O.D. FAN POWER = 170 WATTS S.E.E.R. = 9.80 BTUH/WATT E.E.R. = 10.20 BTUH/WATT NOTE: RATED WITH 25 FEET OF 3/4 SUCTION AND 5/16 LIQUID LINE NOTE: RATED WITH 25 FEET OF 3/4 SUCTION AND 5/16 LIQUID LINE 10 TWE5-PRC000-EN Performance Data Cooling TTB524CA00A WITH TWE030CA40B AT 1528 CMH GROSS CAPACITY IN KILOWATTS O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 6.7 17.2 7.2 19.4 7.8 21.7 8.4 15.0 6.6 17.2 7.1 19.4 7.7 21.7 8.2 15.0 6.5 17.2 7.0 19.4 7.6 21.7 8.1 15.0 6.3 17.2 6.8 19.4 7.3 21.7 7.8 15.0 6.1 17.2 6.6 19.4 7.0 21.7 7.5 15.0 5.7 17.2 6.1 19.4 6.5 21.7 7.0 Metric Units TTB530CA00A WITH TWE030CA40B AT 1700 CMH GROSS CAPACITY IN KILOWATTS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 6.1 6.6 6.9* 7.0* 7.2* 1.90 5.2 5.7 6.2 6.7 7.1 1.97 4.1 4.6 5.1 5.6 6.1 2.04 3.0 3.5 4.0 4.5 5.0 2.11 6.1 6.6 6.8* 7.0* 7.1* 2.01 5.1 5.6 6.1 6.6 7.1 2.07 4.0 4.5 5.0 5.5 6.0 2.14 2.9 3.4 3.9 4.4 4.9 2.21 6.0 6.5* 6.7* 6.9* 7.0* 2.11 5.1 5.6 6.1 6.6 7.0 2.18 4.0 4.5 5.0 5.5 6.0 2.25 2.9 3.4 3.9 4.4 4.9 2.32 5.9 6.4* 6.5* 6.7* 6.9* 2.20 5.0 5.4 5.9 6.4 6.9 2.26 3.9 4.4 4.9 5.4 5.9 2.33 2.8 3.3 3.8 4.3 4.8 2.40 5.8 6.2* 6.3* 6.5* 6.7* 2.29 4.9 5.4 5.9 6.4 6.7 2.35 3.8 4.3 4.8 5.3 5.8 2.41 2.7 3.2 3.7 4.2 4.7 2.48 5.6 5.8* 5.9* 6.1* 6.2* 2.47 4.7 5.2 5.7 6.1 6.2 2.53 3.6 4.1 4.6 5.1 5.6 2.58 2.5 3.0 3.5 4.0 4.5 2.64 O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 8.0 17.2 8.6 19.4 9.3 21.7 9.9 15.0 7.9 17.2 8.5 19.4 9.1 21.7 9.8 15.0 7.8 17.2 8.4 19.4 9.0 21.7 9.7 15.0 7.6 17.2 8.1 19.4 8.7 21.7 9.3 15.0 7.3 17.2 7.9 19.4 8.4 21.7 9.0 15.0 6.8 17.2 7.3 19.4 7.8 21.7 8.4 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 7.1 7.6 8.1* 8.3* 8.5* 2.05 6.0 6.6 7.1 7.7 8.2 2.12 4.8 5.4 5.9 6.5 7.0 2.20 3.6 4.2 4.7 5.3 5.8 2.28 7.1 7.6 8.0* 8.2* 8.4* 2.15 6.0 6.5 7.1 7.6 8.2 2.23 4.8 5.3 5.9 6.4 7.0 2.31 3.5 4.1 4.7 5.2 5.8 2.39 7.0 7.6 7.9* 8.1* 8.3* 2.25 5.9 6.5 7.0 7.6 8.1 2.33 4.7 5.3 5.8 6.4 6.9 2.41 3.5 4.0 4.6 5.2 5.7 2.49 6.9 7.4 7.7* 7.9* 8.1* 2.34 5.8 6.4 6.9 7.4 8.0 2.42 4.6 5.2 5.7 6.3 6.8 2.50 3.4 3.9 4.5 5.0 5.6 2.58 6.8 7.3* 7.5* 7.7* 2.0* 2.43 5.7 6.2 6.8 7.3 7.9 2.51 4.5 5.0 5.6 6.1 6.7 2.59 3.3 3.8 4.4 4.9 5.4 2.67 6.5 6.9* 7.1* 7.2* 7.4* 2.62 5.4 6.0 6.5 7.1 7.4 2.69 4.2 4.8 5.3 5.9 6.4 2.77 3.0 3.6 4.1 4.7 5.2 2.84 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW AIRFLOW TOTAL CAP. COMPR. KW 0.368 X0.98 X0.99 0.486 X1.01 X1.01 AIRFLOW SENS. CAP. 0.368 X0.94 0.486 X1.06 0.472 X1.00 X1.00 0.472 X1.00 X1.00 AIRFLOW SENS. CAP. 0.472 X1.00 VALUES AT ARI RATING CONDITIONS GROSS CAPACITY = 7.54 KW AIRFLOW = 0.42 CMS AIRFLOW = 900. CFM COMPRESSOR POWER = 2245 WATTS I.D. FAN POWER = 425 WATTS O.D. FAN POWER = 165 WATTS COP = 2.67 EER = 9.10 BTU/WATT VALUES AT ARI RATING CONDITIONS GROSS CAPACITY = 9.02 KW AIRFLOW = 0.47 CMS AIRFLOW = 1000. CFM COMPRESSOR POWER = 2410 WATTS I.D. FAN POWER = 440 WATTS O.D. FAN POWER = 170 WATTS COP = 2.99 EER = 10.20 BTU/WATT NOTE: RATED WITH 7.62 METERS OF 3/4 IN. SUCTION AND 5/16 IN. LIQUID LINES NOTE: RATED WITH 7.62 METERS OF 3/4 IN. SUCTION AND 5/16 IN. LIQUID LINES TWE5-PRC000-EN 11 0.472 X1.00 Performance Data Cooling TTB530CA00A WITH TWE040CA40C AT 1200 CFM GROSS CAPACITY IN BTU/H x 1000 O.D. D.B. 85 90 95 100 105 115 I.D. TOTAL W.B. CAP. 59 29.1 63 31.2 67 33.4 71 35.7 59 28.7 63 30.8 67 32.9 71 35.1 59 28.3 63 30.3 67 32.4 71 34.6 59 27.4 63 29.3 67 31.3 71 33.4 59 26.5 63 28.3 67 30.2 71 32.2 59 24.6 63 26.3 67 28.1 71 29.9 English Units TTB536CA00A WITH TWE040CA40C AT 1200 CFM GROSS CAPACITY IN BTU/H x 1000 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 27.5 29.3* 30.1* 30.8* 31.5* 2.18 22.9 25.2 27.5 29.9 31.5* 2.26 17.8 20.2 22.5 24.8 27.1 2.34 12.7 15.0 17.4 19.7 22.0 2.42 27.3 29.0* 29.7* 30.4* 31.1* 2.29 22.7 25.0 27.3 29.7 31.1* 2.37 17.6 20.0 22.3 24.6 26.9 2.45 12.5 14.8 17.2 19.5 21.8 2.54 27.1 28.6* 29.4* 30.1* 30.7* 2.40 22.5 24.8 27.1 29.5 30.7* 2.48 17.4 19.8 22.1 24.4 26.7 2.56 12.3 14.6 16.9 19.3 21.6 2.65 26.7 27.9* 28.6* 29.2* 29.9* 2.49 22.1 24.4 26.7 29.0 29.9* 2.57 17.0 19.3 21.7 24.0 26.3 2.65 11.9 14.2 16.5 18.8 21.2 2.74 26.3 27.1* 27.8* 28.4* 29.0* 2.58 21.7 24.0 26.3 28.4* 29.0* 2.66 16.6 18.9 21.2 23.6 25.9 2.74 11.4 13.8 16.1 18.4 20.7 2.83 24.8* 25.5* 26.1* 26.7* 27.3* 2.76 20.8 23.1 25.5 26.7* 27.3* 2.84 15.7 18.1 20.4 22.7 25.0 2.92 10.6 12.9 15.2 17.6 19.9 3.01 O.D. D.B. 85 90 95 100 105 115 I.D. TOTAL W.B. CAP. 59 35.2 63 37.8 67 40.5 71 43.3 59 34.6 63 37.1 67 39.8 71 42.5 59 33.9 63 36.4 67 39.0 71 41.7 59 32.7 63 35.1 67 37.6 71 40.2 59 31.5 63 33.8 67 36.2 71 38.7 59 29.1 63 31.2 67 33.4 71 35.7 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 30.5 32.8 35.2 36.0* 36.9* 2.61 25.9 28.3 30.6 32.9 35.3 2.72 20.9 23.2 25.5 27.9 30.2 2.83 15.7 18.0 20.4 22.7 25.0 2.94 30.2 32.5 34.7* 35.5* 36.4* 2.75 25.6 27.9 30.3 32.6 35.0 2.85 20.5 22.9 25.2 27.6 29.9 2.96 15.4 17.7 20.0 22.4 24.7 3.08 29.9 32.2 34.1* 35.0* 35.8* 2.88 25.3 27.6 30.0 32.3 34.6 2.99 20.2 22.6 24.9 27.2 29.6 3.10 15.0 17.4 19.7 22.1 24.4 3.21 29.3 31.7 33.2* 34.0* 34.8* 2.98 24.7 27.1 29.4 31.7 34.1 3.09 19.7 22.0 24.3 26.7 29.0 3.20 14.5 16.8 19.2 21.5 23.8 3.31 28.8 31.1 32.2* 33.0* 33.7* 3.08 24.2 26.5 28.8 31.2 33.5 3.18 19.1 21.4 23.8 26.1 28.4 3.29 13.9 16.2 18.6 20.9 23.3 3.40 27.6 29.4* 30.2* 30.9* 31.6* 3.29 23.0 25.4 27.7 30.0 31.6* 3.38 18.0 20.3 22.6 25.0 27.3 3.48 12.8 15.1 17.5 19.8 22.1 3.59 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW AIRFLOW TOTAL CAP. COMPR. KW 1200 X1.00 X1.00 1200 X1.00 X1.00 AIRFLOW SENS. CAP. 1200 X1.00 1200 X1.00 1200 X1.00 X1.00 1200 X1.00 X1.00 AIRFLOW SENS. CAP. VALUES AT 95/80/67 RATING CONDITIONS VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 32400 BTUH AIRFLOW = 1200 CFM COMPRESSOR POWER = 2562 WATTS I.D. FAN POWER = 325 WATTS O.D. FAN POWER = 170 WATTS S.E.E.R. = 10.82 BTUH/WATT E.E.R. = 10.60 BTUH/WATT GROSS CAPACITY = 39000 BTUH AIRFLOW = 1200 CFM COMPRESSOR POWER = 3099 WATTS I.D. FAN POWER = 325 WATTS O.D. FAN POWER = 170 WATTS S.E.E.R. = 10.95 BTUH/WATT E.E.R. = 10.85 BTUH/WATT NOTE: RATED WITH 25 FEET OF 3/4 SUCTION AND 5/16 LIQUID LINE NOTE: RATED WITH 25 FEET OF 3/4 SUCTION AND 5/16 LIQUID LINE 12 1200 X1.00 1200 X1.00 TWE5-PRC000-EN Performance Data Cooling TTB530CA00A WITH TWE040CA40C AT 2039 CMH GROSS CAPACITY IN KILOWATTS O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 8.5 17.2 9.1 19.4 9.8 21.7 10.5 15.0 8.4 17.2 9.0 19.4 9.6 21.7 10.3 15.0 8.3 17.2 8.9 19.4 9.5 21.7 10.1 15.0 8.0 17.2 8.6 19.4 9.2 21.7 9.8 15.0 7.8 17.2 8.3 19.4 8.8 21.7 9.4 15.0 7.2 17.2 7.7 19.4 8.2 21.7 8.8 Metric Units TTB536CA00A WITH TWE040CA40C AT 2039 CMH GROSS CAPACITY IN KILOWATTS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 8.1 8.6* 8.8* 9.0* 9.2* 2.18 6.7 7.4 8.1 8.8 9.2* 2.26 5.2 5.9 6.6 7.3 7.9 2.34 3.7 4.4 5.1 5.8 6.4 2.42 8.0 8.5* 8.7* 8.9* 9.1* 2.29 6.7 7.3 8.0 8.7 9.1* 2.37 5.2 5.9 6.5 7.2 7.9 2.45 3.7 4.3 5.0 5.7 6.4 2.54 7.9 8.4* 8.6* 8.8* 9.0* 2.40 6.6 7.3 7.9 8.6 9.0* 2.48 5.1 5.8 6.5 7.1 7.8 2.56 3.6 4.3 5.0 5.7 6.3 2.65 7.8 8.2* 8.4* 8.6* 8.8* 2.49 6.5 7.1 7.8 8.5 8.8* 2.57 5.0 5.7 6.4 7.0 7.7 2.65 3.5 4.2 4.8 5.5 6.2 2.74 7.7 7.9* 8.1* 8.3* 8.5* 2.58 6.4 7.0 7.7 8.3* 8.5* 2.66 4.9 5.5 6.2 6.9 7.6 2.74 3.3 4.0 4.7 5.4 6.1 2.83 7.3* 7.5* 7.6* 7.8* 8.0* 2.76 6.1 6.8 7.5 7.8 8.0 2.84 4.6 5.3 6.0 6.7 7.3 2.92 3.1 3.8 4.5 5.2 5.8 3.01 O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 10.3 17.2 11.1 19.4 11.9 21.7 12.7 15.0 10.1 17.2 10.9 19.4 11.7 21.7 12.5 15.0 9.9 17.2 10.7 19.4 11.4 21.7 12.2 15.0 9.6 17.2 10.3 19.4 11.0 21.7 11.8 15.0 9.2 17.2 9.9 19.4 10.6 21.7 11.3 15.0 8.5 17.2 9.1 19.4 9.8 21.7 10.5 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 8.9 9.6 10.3 10.5* 10.8* 2.61 7.6 8.3 9.0 9.6 10.3 2.72 6.1 6.8 7.5 8.2 8.8 2.83 4.6 5.3 6.0 6.7 7.3 2.94 8.8 9.5 10.2* 10.4* 10.7* 2.75 7.5 8.2 8.9 9.6 10.3 2.85 6.0 6.7 7.4 8.1 8.8 2.96 4.5 5.2 5.9 6.6 7.2 3.08 8.8 9.4 10.0* 10.3* 10.5* 2.88 7.4 8.1 8.8 9.5 10.1 2.99 5.9 6.6 7.3 8.0 8.7 3.10 4.4 5.1 5.8 6.5 7.1 3.21 8.6 9.3 9.7* 10.0* 10.2* 2.98 7.2 7.9 8.6 9.3 10.0 3.09 5.8 6.4 7.1 7.8 8.5 3.20 4.2 4.9 5.6 6.3 7.0 3.31 8.4 9.1 9.4* 9.7* 9.9* 3.08 7.1 7.8 8.4 9.1 9.8 3.18 5.6 6.3 7.0 7.6 8.3 3.29 4.1 4.7 5.4 6.1 6.8 3.40 8.1 8.6* 8.8* 9.1* 9.3* 3.29 6.7 7.4 8.1 8.8 9.3* 3.38 5.3 5.9 6.6 7.3 8.0 3.48 3.8 4.4 5.1 5.8 6.5 3.59 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW AIRFLOW TOTAL CAP. COMPR. KW 566 X1.00 X1.00 566 X1.00 X1.00 AIRFLOW SENS. CAP. 566 X1.00 566 X1.00 566 X1.00 X1.00 566 X1.00 X1.00 AIRFLOW SENS. CAP. 566 X1.00 VALUES AT ARI RATING CONDITIONS VALUES AT ARI RATING CONDITIONS GROSS CAPACITY = 9.48 KW AIRFLOW = 0.57 CMS COMPRESSOR POWER = 2562WATTS I.D. FAN POWER = 325 WATTS O.D. FAN POWER = 170 WATTS COP = 3.11 EER = 10.60 BTU/WATT GROSS CAPACITY = 11.41 KW AIRFLOW = 0.57 CMS COMPRESSOR POWER = 3099 WATTS I.D. FAN POWER = 325 WATTS O.D. FAN POWER = 170 WATTS COP = 3.18 EER = 10.85 BTU/WATT NOTE: RATED WITH 7.62 METERS OF 3/4 IN. SUCTION AND 5/16 IN. LIQUID LINES NOTE: RATED WITH 7.62 METERS OF 3/4 IN. SUCTION AND 5/16 IN. LIQUID LINES TWE5-PRC000-EN 13 566 X1.00 Performance Data Cooling TTA030CD WITH TWE030CA4 AT 1000 CFM GROSS CAPACITY IN BTU/H x 1000 O.D. D.B. 85 90 95 100 105 115 I.D. TOTAL W.B. CAP. 59 27.3 63 29.5 67 31.7 71 34.1 59 26.8 63 28.9 67 31.1 71 33.4 59 26.3 63 28.3 67 30.5 71 32.7 59 25.6 63 27.6 67 29.7 71 31.8 59 24.9 63 26.9 67 28.9 71 31.0 59 23.6 63 25.4 67 27.3 71 29.2 TTA030CD WITH TWE040CA4-B AT 1125 CFM GROSS CAPACITY IN BTU/H x 1000 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 21.8 23.5 25.2 26.9 27.9* 2.27 18.5 20.2 21.9 23.6 25.3 2.35 14.9 16.6 18.3 20.0 21.7 2.43 11.2 12.9 14.6 16.3 18.0 2.51 21.6 23.3 25.0 26.7 27.5* 2.38 18.3 20.0 21.7 23.4 25.1 2.46 14.7 16.4 18.1 19.8 21.5 2.54 10.9 12.6 14.3 16.0 17.7 2.63 21.4 23.1 24.8 26.4* 27.1* 2.49 18.1 19.8 21.5 23.2 24.9 2.57 14.4 16.1 17.8 19.5 21.2 2.65 10.7 12.4 14.1 15.8 17.5 2.74 21.1 22.8 24.5 25.9* 26.5* 2.61 17.8 19.5 21.2 22.9 24.6 2.69 14.1 15.8 17.5 19.2 20.9 2.77 10.4 12.1 13.8 15.5 17.2 2.85 20.8 22.5 24.2 25.3* 26.0* 2.73 17.5 19.2 20.9 22.6 24.3 2.80 13.8 15.5 17.2 18.9 20.6 2.88 10.1 11.8 13.5 15.2 16.9 2.96 20.2 21.9 23.7* 24.2* 24.8* 2.97 16.9 18.6 20.3 22.0 23.7 3.04 13.2 14.9 16.6 18.3 20.0 3.11 9.5 11.2 12.9 14.6 16.3 3.19 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW 975 X0.98 X0.99 1275 X1.01 X1.01 AIRFLOW SENS. CAP. 975 X0.94 English Units 1275 X1.06 O.D. D.B. 85 90 95 100 105 115 I.D. TOTAL W.B. CAP. 59 29.4 63 31.7 67 34.0 71 36.5 59 28.8 63 31.0 67 33.3 71 35.6 59 28.2 63 30.3 67 32.5 71 34.8 59 27.4 63 29.4 67 31.5 71 33.8 59 26.6 63 28.5 67 30.6 71 32.7 59 25.0 63 26.8 67 28.7 71 30.6 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 24.8 26.8 28.9 30.0* 30.7* 2.34 20.9 22.9 24.9 27.0 29.0 2.42 16.5 18.5 20.6 22.6 24.6 2.50 12.1 14.1 16.1 18.1 20.2 2.59 24.6 26.6 28.6 29.5* 30.2* 2.45 20.6 22.6 24.6 26.7 28.7 2.53 16.2 18.2 20.3 22.3 24.3 2.62 11.8 13.8 15.8 17.8 19.9 2.71 24.3 26.3 28.3* 29.0* 29.7* 2.57 20.3 22.3 24.4 26.4 28.4 2.65 15.9 18.0 20.0 22.0 24.0 2.73 11.5 13.5 15.5 17.6 19.6 2.82 23.9 26.0 27.7* 28.3* 29.0* 2.69 20.0 22.0 24.0 26.0 28.1 2.77 15.6 17.6 19.6 21.7 23.7 2.85 11.1 13.1 15.2 17.2 19.2 2.94 23.6 25.6 27.0* 27.6* 28.3* 2.81 19.6 21.6 23.7 25.7 27.7 2.89 15.2 17.3 19.3 21.3 23.3 2.97 10.8 12.8 14.8 16.8 18.9 3.05 22.9 25.0 25.7* 26.3* 26.9* 3.06 18.9 21.0 23.0 25.0 26.9* 3.13 14.5 16.6 18.6 20.6 22.6 3.20 10.0 12.1 14.1 16.1 18.2 3.28 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW 975 1275 AIRFLOW 975 1275 TOTAL CAP. X0.98 X1.01 SENS. CAP. X0.94 X1.06 COMPR. KW X0.99 X1.01 VALUES AT 95/80/67 RATING CONDITIONS VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 32500 BTUH AIRFLOW = 1125 CFM COMPRESSOR POWER = 2733 WATTS I.D. FAN POWER = 290 WATTS O.D. FAN POWER = 227 WATTS E.E.R. = 9.60 BTUH/WATT GROSS CAPACITY = 32500 BTUH AIRFLOW = 1125 CFM COMPRESSOR POWER = 2733 WATTS I.D. FAN POWER = 290 WATTS O.D. FAN POWER = 227 WATTS E.E.R. = 9.60 BTUH/WATT NOTE: RATED WITH 25 FEET OF 7/8 SUCTION AND 3/8 LIQUID LINE NOTE: RATED WITH 25 FEET OF 7/8 SUCTION AND 3/8 LIQUID LINE * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F 14 TWE5-PRC000-EN Performance Data Cooling TTA030CD00A WITH TWE030CA40B AT 1700 CMH GROSS CAPACITY IN KILOWATTS O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 8.0 17.2 8.6 19.4 9.3 21.7 10.0 15.0 7.9 17.2 8.5 19.4 9.1 21.7 9.8 15.0 7.7 17.2 8.3 19.4 8.9 21.7 9.6 15.0 7.5 17.2 8.1 19.4 8.7 21.7 9.3 15.0 7.3 17.2 7.9 19.4 8.5 21.7 9.1 15.0 6.9 17.2 7.4 19.4 8.0 21.7 8.6 Metric Units TTA030CD00A WITH TWE040CA40C AT 1911 CMH GROSS CAPACITY IN KILOWATTS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 6.4 6.9 7.4 7.9 8.2* 2.27 5.4 5.9 6.4 6.9 7.4 2.35 4.4 4.9 5.4 5.9 6.4 2.43 3.3 3.8 4.3 4.8 5.3 2.51 6.3 6.8 7.3 7.8 8.1* 2.38 5.4 5.9 6.4 6.9 7.4 2.46 4.3 4.8 5.3 5.8 6.3 2.54 3.2 3.7 4.2 4.7 5.2 2.63 6.3 6.8 7.3 7.7* 7.9* 2.49 5.3 5.8 6.3 6.8 7.3 2.57 4.2 4.7 5.2 5.7 6.2 2.65 3.1 3.6 4.1 4.6 5.1 2.74 6.2 6.7 7.2 7.6* 7.8* 2.61 5.2 5.7 6.2 6.7 7.2 2.69 4.1 4.6 5.1 5.6 6.1 2.77 3.0 3.5 4.0 4.5 5.0 2.85 6.1 6.6 7.1 7.4* 7.6* 2.73 5.1 5.6 6.1 6.6 7.1 2.80 4.0 4.5 5.0 5.5 6.0 2.88 3.0 3.5 4.0 4.5 5.0 2.96 5.9 6.4 6.9* 7.1* 7.3* 2.97 5.0 5.4 5.9 6.4 6.9 3.04 3.9 4.4 4.9 5.4 5.9 3.11 2.8 3.3 3.8 4.3 4.8 3.19 O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 8.6 17.2 9.3 19.4 10.0 21.7 10.7 15.0 8.4 17.2 9.1 19.4 9.8 21.7 10.4 15.0 8.3 17.2 8.9 19.4 9.5 21.7 10.2 15.0 8.0 17.2 8.6 19.4 9.2 21.7 9.9 15.0 7.8 17.2 8.4 19.4 9.0 21.7 9.6 15.0 7.3 17.2 7.9 19.4 8.4 21.7 9.0 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 7.3 7.9 8.5 8.8* 9.0* 2.34 6.1 6.7 7.3 7.9 8.5 2.42 4.8 5.4 6.0 6.6 7.2 2.50 3.5 4.1 4.7 5.3 5.9 2.59 7.2 7.8 8.4 8.6* 8.8* 2.45 6.0 6.6 7.2 7.8 8.4 2.53 4.7 5.3 5.9 6.5 7.1 2.62 3.5 4.0 4.6 5.2 5.8 2.71 7.1 7.7 8.3* 8.5* 8.7* 2.57 5.9 6.5 7.1 7.7 8.3 2.65 4.7 5.3 5.9 6.4 7.0 2.73 3.4 4.0 4.5 5.2 5.7 2.82 7.0 7.6 8.1* 8.3* 8.5* 2.69 5.9 6.4 7.0 7.6 8.2 2.77 4.6 5.2 5.7 6.4 6.9 2.85 3.3 3.8 4.5 5.0 5.6 2.94 6.9 7.5 7.9* 8.1* 8.3* 2.81 5.7 6.3 6.9 7.5 8.1 2.89 4.5 5.1 5.7 6.2 6.8 2.97 3.2 3.8 4.3 4.9 5.5 3.05 6.7 7.3 7.5* 7.7* 7.9* 3.06 5.5 6.2 6.7 7.3 7.9* 3.13 4.2 4.9 5.4 6.0 6.6 3.20 2.9 3.5 4.1 4.7 5.3 3.28 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW AIRFLOW TOTAL CAP. COMPR. KW 975 X0.98 X0.99 1275 X1.01 X1.01 AIRFLOW SENS. CAP. 975 X0.94 1275 X1.06 975 X0.98 X0.99 1275 X1.01 X1.01 AIRFLOW SENS. CAP. 975 X0.94 VALUES AT 95/80/67 RATING CONDITIONS VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 8.94 KW AIRFLOW = 0.57 CMS COMPRESSOR POWER = 2653 WATTS I.D. FAN POWER = 430 WATTS O.D. FAN POWER = 227 WATTS EER = 8.75 BTU/WATT GROSS CAPACITY = 9.5 KW AIRFLOW = 1913 CMH COMPRESSOR POWER = 2653 WATTS I.D. FAN POWER = 430 WATTS O.D. FAN POWER = 227 WATTS EER = 8.75 BTU/WATT NOTE: RATED WITH 7.62 METERS OF 7/8 IN. SUCTION AND 7/8 IN. LIQUID LINES NOTE: RATED WITH 7.62 METERS OF 7/8 IN. SUCTION AND 7/8 IN. LIQUID LINES * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F TWE5-PRC000-EN 15 1275 X1.06 Performance Data Cooling TTA040CD WITH TWE040CA4B AT 1325 CFM GROSS CAPACITY IN BTU/H x 1000 O.D. D.B. 85 90 95 100 105 115 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 GROSS CAP. 36.9 39.7 42.6 45.6 36.2 38.9 41.7 44.6 35.4 38.0 40.8 43.6 34.5 37.0 39.7 42.4 33.5 36.0 38.6 41.2 31.6 33.9 36.3 38.8 English Units TTA040CD WITH TWE050CA5C AT 1600 CFM GROSS CAPACITY IN BTU/H x 1000 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 29.5 31.8 34.1 36.4 37.7* 3.24 25.0 27.3 29.6 31.9 34.2 3.37 20.0 22.3 24.6 26.9 29.3 3.51 14.9 17.2 19.6 21.9 24.2 3.64 29.2 31.5 33.8 36.1 37.1* 3.39 24.7 27.0 29.3 31.6 33.9 3.53 19.7 22.0 24.3 26.6 28.9 3.66 14.6 16.9 19.2 21.5 23.8 3.81 28.9 31.2 33.5 35.6* 36.5* 3.54 24.3 26.6 29.0 31.3 33.6 3.68 19.3 21.7 24.0 26.3 28.6 3.82 14.2 16.6 18.9 21.2 23.5 3.97 28.5 30.8 33.1 34.9* 35.7* 3.70 23.9 26.2 28.5 30.9 33.2 3.84 18.9 21.2 23.5 25.9 28.2 3.99 13.8 16.1 18.4 20.7 23.1 4.14 28.1 30.4 32.7 34.1* 34.9* 3.85 23.5 25.8 28.1 30.4 32.8 4.00 18.5 20.8 23.1 25.4 27.7 4.15 13.4 15.7 18.0 20.3 22.6 4.31 27.3 29.6 31.8* 32.5* 33.3* 4.17 22.7 25.0 27.3 29.6 31.9 4.32 17.7 20.0 22.3 24.6 26.9 4.48 12.6 14.9 17.2 19.5 21.8 4.65 O.D. D.B. 85 90 95 100 105 115 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 GROSS CAP. 40.5 43.4 46.4 49.5 39.4 42.2 45.1 48.2 38.4 41.1 43.9 46.8 37.3 39.9 42.6 45.4 36.1 38.7 41.3 44.0 33.9 36.2 38.7 41.2 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 34.2 37.0 39.9 41.3* 42.2* 3.16 28.6 31.5 34.3 37.1 39.9 3.29 22.5 25.3 28.1 31.0 33.8 3.43 16.2 19.1 21.9 24.7 27.5 3.57 33.8 36.6 39.4 40.4* 41.3* 3.29 28.2 31.0 33.8 36.7 39.5 3.42 22.0 24.9 27.7 30.5 33.3 3.57 15.8 18.6 21.4 24.2 27.1 3.71 33.3 36.2 38.7* 39.6* 40.4* 3.42 27.7 30.6 33.4 36.2 39.0 3.56 21.6 24.4 27.2 30.0 32.9 3.70 15.3 18.1 21.0 23.8 26.6 3.85 32.9 35.7 37.7* 38.6* 39.5* 3.55 27.3 30.1 32.9 35.7 38.5 3.69 21.1 23.9 26.7 29.6 32.4 3.84 14.8 17.7 20.5 23.3 26.1 4.00 32.4 35.2 36.8* 37.7* 38.5* 3.69 26.8 29.6 32.4 35.2 38.1 3.83 20.6 23.5 26.3 29.1 31.9 3.98 14.4 17.2 20.0 22.8 25.6 4.14 31.5 34.1* 34.9* 35.7* 36.5* 3.96 25.8 28.7 31.5 34.3 36.5* 4.11 19.7 22.5 25.3 28.1 31.0 4.26 13.4 16.2 19.1 21.9 24.7 4.42 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW AIRFLOW TOTAL CAP. COMPR. KW 1150 X0.98 X0.99 1500 X1.02 X1.01 AIRFLOW SENS. CAP. 1150 X0.94 1500 X1.06 1375 X0.98 X0.99 1775 X1.01 X1.01 AIRFLOW SENS. CAP. 1375 X0.93 VALUES AT 95/80/67 RATING CONDITIONS VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 40800 BTUH AIRFLOW = 1325 CFM COMPRESSOR POWER = 3820 WATTS I.D. FAN POWER = 380 WATTS O.D. FAN POWER = 197 WATTS E.E.R. = 9.00 BTUH/WATT GROSS CAPACITY = 43900 BTUH AIRFLOW = 1570 CFM COMPRESSOR POWER = 3720 WATTS I.D. FAN POWER = 530 WATTS O.D. FAN POWER = 197 WATTS E.E.R. = 9.45 BTUH/WATT NOTE: RATED WITH 25 FEET OF 1-1/8 SUCTION AND 3/8 LIQUID LINE NOTE: RATED WITH 25 FEET OF 1-1/8 SUCTION AND 3/8 LIQUID LINE * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F 16 1775 X1.05 TWE5-PRC000-EN Performance Data Cooling TTA040CD00A WITH TWE050CA50D AT 2717 CMH GROSS CAPACITY IN KILOWATTS TTA040CD00A WITH TWE040CA40C AT 2250 CMH GROSS CAPACITY IN KILOWATTS O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 10.8 17.2 11.6 19.4 12.5 21.7 13.4 15.0 10.6 17.2 11.4 19.4 12.2 21.7 13.1 15.0 10.4 17.2 11.1 19.4 12.0 21.7 12.8 15.0 10.1 17.2 10.8 19.4 11.6 21.7 12.4 15.0 9.8 17.2 10.5 19.4 11.3 21.7 12.1 15.0 9.3 17.2 9.9 19.4 10.6 21.7 11.4 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 8.6 9.3 10.0 10.7 11.0* 3.24 7.3 8.0 8.7 9.3 10.0 3.37 5.9 6.5 7.2 7.9 8.6 3.51 4.4 5.0 5.7 6.4 7.1 3.64 8.6 9.2 9.9 10.6 10.9* 3.39 7.2 7.9 8.6 9.3 9.9 3.53 5.8 6.4 7.1 7.8 8.5 3.66 4.3 5.0 5.6 6.3 7.0 3.81 8.5 9.1 9.8 10.4* 10.7* 3.54 7.1 7.8 8.5 9.2 9.8 3.68 5.7 6.4 7.0 7.7 8.4 3.82 4.2 4.9 5.5 6.2 6.9 3.97 8.4 9.0 9.7 10.2* 10.5* 3.70 7.0 7.7 8.4 9.1 9.7 3.84 5.5 6.2 6.9 7.6 8.3 3.99 4.0 4.7 5.4 6.1 6.8 4.14 8.2 8.9 9.6* 10.0* 10.2* 3.85 6.9 7.6 8.2 8.9 9.6 4.00 5.4 6.1 6.8 7.4 8.1 4.15 3.9 4.6 5.3 5.9 6.6 4.31 8.0 8.7 9.3* 9.5* 9.8* 4.17 6.7 7.3 8.0 8.7 9.3 4.32 5.2 5.9 6.5 7.2 7.9 4.48 3.7 4.4 5.0 5.7 6.4 4.65 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW 1150 X0.98 X0.99 1500 X1.02 X1.01 AIRFLOW SENS. CAP. 1150 X0.94 Metric Units 1500 X1.06 O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 11.9 17.2 12.7 19.4 13.6 21.7 14.5 15.0 11.5 17.2 12.4 19.4 13.2 21.7 14.1 15.0 11.3 17.2 12.0 19.4 12.9 21.7 13.7 15.0 10.9 17.2 11.7 19.4 12.5 21.7 13.3 15.0 10.6 17.2 11.3 19.4 12.1 21.7 12.9 15.0 9.9 17.2 10.6 19.4 11.3 21.7 12.1 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 10.0 10.8 11.7 12.1* 12.4* 3.16 8.4 9.2 10.0 10.9 11.7 3.29 6.6 7.4 8.2 9.1 9.9 3.43 4.7 5.6 6.4 7.2 8.1 3.57 9.9 10.7 11.5 11.8* 12.1* 3.29 8.3 9.1 9.9 10.8 11.6 3.42 6.4 7.3 8.1 8.9 9.8 3.57 4.6 5.4 6.3 7.1 7.9 3.71 9.8 10.6 11.3* 11.6* 11.8* 3.42 8.1 9.0 9.8 10.6 11.4 3.56 6.3 7.1 8.0 8.8 9.6 3.70 4.5 5.3 6.2 7.0 7.8 3.85 9.6 10.5 11.0* 11.3* 11.6* 3.55 8.0 8.8 9.6 10.5 11.3 3.69 6.2 7.0 7.8 8.7 9.5 3.84 4.3 5.2 6.0 6.8 7.6 4.00 9.5 10.3 10.8* 11.0* 11.3* 3.69 7.9 8.7 9.5 10.3 11.2 3.83 6.0 6.9 7.7 8.5 9.3 3.98 4.2 5.0 5.9 6.7 7.5 4.14 9.2 10.0* 10.2* 10.5* 10.7* 3.96 7.6 8.4 9.2 10.0 10.7 4.11 5.8 6.6 7.4 8.2 9.1 4.26 3.9 4.7 5.6 6.4 7.2 4.42 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW 1375 1775 AIRFLOW 1375 1775 TOTAL CAP. X0.98 X1.01 SENS. CAP. X0.93 X1.05 COMPR. KW X0.99 X1.01 VALUES AT 95/80/67 RATING CONDITIONS VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 12.0 KW AIRFLOW = 2253 CMS COMPRESSOR POWER = 3820 WATTS I.D. FAN POWER = 380 WATTS O.D. FAN POWER = 197 WATTS EER = 9.00 BTU/WATT GROSS CAPACITY = 12.0 KW AIRFLOW = 2253 CMS COMPRESSOR POWER = 3720 WATTS I.D. FAN POWER = 380 WATTS O.D. FAN POWER = 197 WATTS EER = 9.00 BTU/WATT NOTE: RATED WITH 7.62 METERS OF 1-1/8 IN. SUCTION AND 3/8 IN. LIQUID LINES NOTE: RATED WITH 7.62 METERS OF 1-1/8 IN. SUCTION AND 3/8 IN. LIQUID LINES * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F TWE5-PRC000-EN 17 Performance Data Cooling TTA060CD WITH TWE050CA5C AT 1800 CFM GROSS CAPACITY IN BTU/H x 1000 TTA050CD WITH TWE050CA5C AT 1800 CFM GROSS CAPACITY IN BTU/H x 1000 O.D. D.B. 85 90 95 100 105 115 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 GROSS CAP. 48.8 52.1 55.5 59.0 47.6 50.8 54.1 57.5 46.4 49.5 52.7 56.0 45.1 48.1 51.2 54.4 43.8 46.7 49.6 52.7 41.2 43.8 46.6 49.4 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 39.4 42.5 45.6 48.7 49.9* 3.62 33.2 36.3 39.4 42.5 45.6 3.75 26.3 29.4 32.5 35.6 38.7 3.89 19.3 22.4 25.5 28.6 31.7 4.03 38.9 42.0 45.1 47.9* 48.9* 3.77 32.7 35.8 38.9 42.0 45.1 3.91 25.8 28.9 32.0 35.1 38.2 4.05 18.8 21.9 25.0 28.1 31.2 4.19 38.4 41.5 44.6 47.0* 47.9* 3.93 32.1 35.3 38.4 41.5 44.6 4.07 25.3 28.4 31.5 34.6 37.7 4.21 18.3 21.4 24.5 27.6 30.7 4.35 37.8 40.9 44.0 45.9* 46.8* 4.09 31.6 34.7 37.8 40.9 44.0 4.23 24.7 27.8 30.9 34.0 37.1 4.37 17.7 20.8 23.9 27.0 30.1 4.51 37.3 40.4 43.5 44.8* 45.7* 4.25 31.0 34.1 37.2 40.3 43.4 4.38 24.2 27.3 30.4 33.5 36.6 4.52 17.2 20.3 23.4 26.5 29.6 4.67 36.2 39.3 41.6* 42.5* 43.4* 4.57 29.9 33.0 36.1 39.2 42.3 4.71 23.0 26.1 29.2 32.3 35.4 4.84 16.1 19.2 22.3 25.4 28.5 4.98 English Units O.D. D.B. 85 90 95 100 105 115 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 GROSS CAP. 57.5 61.6 65.8 70.2 56.2 60.2 64.3 68.6 54.9 58.8 62.8 66.9 53.5 57.3 61.2 65.2 52.2 55.8 59.6 63.5 49.4 52.8 56.4 60.0 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 72 74 76 78 80 KW 43.6 46.8 49.9 53.0 56.2 4.71 37.4 40.6 43.7 46.8 50.0 4.87 30.6 33.7 36.8 40.0 43.1 5.04 23.5 26.7 29.8 32.9 36.1 5.22 43.0 46.2 49.3 52.5 55.6 4.90 36.9 40.0 43.1 46.3 49.4 5.06 30.0 33.1 36.2 39.4 42.5 5.23 22.9 26.1 29.2 32.3 35.5 5.40 42.5 45.6 48.7 51.9 55.0* 5.09 36.3 39.4 42.5 45.7 48.8 5.25 29.4 32.5 35.7 38.8 41.9 5.42 22.3 25.5 28.6 31.7 34.9 5.59 41.9 45.0 48.1 51.3 54.0* 5.31 35.7 38.8 41.9 45.1 48.2 5.47 28.8 31.9 35.0 38.2 41.3 5.63 21.7 24.9 28.0 31.1 34.3 5.79 41.3 44.4 47.5 50.7 52.9* 5.53 35.0 38.2 41.3 44.5 47.6 5.68 28.2 31.3 34.4 37.6 40.7 5.84 21.1 24.2 27.4 30.5 33.7 6.00 40.1 43.2 46.3 49.4* 50.6* 5.98 33.8 37.0 40.1 43.2 46.4 6.12 26.9 30.1 33.2 36.3 39.5 6.26 19.9 23.0 26.2 29.3 32.4 6.41 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW 1525 1975 AIRFLOW 1525 1975 TOTAL CAP. X0.98 X1.01 SENS. CAP. X0.93 X1.04 COMPR. KW X0.99 X1.01 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) VALUES AT 95/80/67 RATING CONDITIONS VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 52500 BTUH AIRFLOW = 1750 CFM COMPRESSOR POWER = 4202 WATTS I.D. FAN POWER = 730 WATTS O.D. FAN POWER = 202 WATTS E.E.R. = 9.75 BTUH/WATT GROSS CAPACITY = 62500 BTUH AIRFLOW = 1750 CFM COMPRESSOR POWER = 5402 WATTS I.D. FAN POWER = 730 WATTS O.D. FAN POWER = 386 WATTS E.E.R. = 9.15 BTUH/WATT NOTE: RATED WITH 25 FEET OF 1-1/8 SUCTION AND 3/8 LIQUID LINE NOTE: RATED WITH 25 FEET OF 1-1/8 SUCTION AND 3/8 LIQUID LINE * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F AIRFLOW TOTAL CAP. COMPR. KW 18 1525 X0.98 X0.98 1975 X1.01 X1.01 AIRFLOW SENS. CAP. 1525 X0.94 1975 X1.04 TWE5-PRC000-EN Performance Data Cooling TTA060CD WITH TWE050CA5C AT 3056 CMH GROSS CAPACITY IN KILOWATTS TTA050CD WITH TWE050CA5C AT 3056 CMH GROSS CAPACITY IN KILOWATTS O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 14.3 17.2 15.3 19.4 16.3 21.7 17.3 15.0 13.9 17.2 14.9 19.4 15.9 21.7 16.8 15.0 13.6 17.2 14.5 19.4 15.4 21.7 16.4 15.0 13.2 17.2 14.1 19.4 15.0 21.7 15.9 15.0 12.8 17.2 13.7 19.4 14.5 21.7 15.4 15.0 12.1 17.2 12.8 19.4 13.7 21.7 14.5 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 11.5 12.5 13.4 14.3 14.6* 3.62 9.7 10.6 11.5 12.5 13.4 3.75 7.7 8.6 9.5 10.4 11.3 3.89 5.7 6.6 7.5 8.4 9.3 4.03 11.4 12.3 13.2 14.0* 14.3* 3.77 9.6 10.5 11.4 12.3 13.2 3.91 7.6 8.5 9.4 10.3 11.2 4.05 5.5 6.4 7.3 8.2 9.1 4.19 11.3 12.2 13.1 13.8* 14.0* 3.93 9.4 10.3 11.3 12.2 13.1 4.07 7.4 8.3 9.2 10.1 11.0 4.21 5.4 6.3 7.2 8.1 9.0 4.35 11.1 12.0 12.9 13.4* 13.7* 4.09 9.3 10.2 11.1 12.0 12.9 4.23 7.2 8.1 9.1 10.0 10.9 4.37 5.2 6.1 7.0 7.9 8.8 4.51 10.9 11.8 12.7 13.1* 13.4* 4.25 9.1 10.0 10.9 11.8 12.7 4.38 7.1 8.0 8.9 9.8 10.7 4.52 5.0 5.9 6.9 7.8 8.7 4.67 10.6 11.5 12.2* 12.5* 12.7* 4.57 8.8 9.7 10.6 11.5 12.4 4.71 6.7 7.6 8.6 9.5 10.4 4.84 4.7 5.6 6.5 7.4 8.4 4.98 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW TOTAL CAP. COMPR. KW 1525 X0.98 X0.99 1975 X1.01 X1.01 AIRFLOW SENS. CAP. 1525 X0.93 Metric Units 1975 X1.04 O.D. D.B. 29.4 32.2 35.0 37.8 40.6 46.1 I.D. TOTAL W.B. CAP. 15.0 16.8 17.2 18.0 19.4 19.3 21.7 20.6 15.0 16.5 17.2 17.6 19.4 18.8 21.7 20.1 15.0 16.1 17.2 17.2 19.4 18.4 21.7 19.6 15.0 15.7 17.2 16.8 19.4 17.9 21.7 19.1 15.0 15.3 17.2 16.3 19.4 17.5 21.7 18.6 15.0 14.5 17.2 15.5 19.4 16.5 21.7 17.6 SENS. CAP. AT ENTERING D.B. TEMP. COMPR. 22.2 23.3 24.4 25.6 26.7 KW 12.8 13.7 14.6 15.5 16.5 4.71 11.0 11.9 12.8 13.7 14.7 4.87 9.0 9.9 10.8 11.7 12.6 5.04 6.9 7.8 8.7 9.6 10.6 5.22 12.6 13.5 14.4 15.4 16.3 4.90 10.8 11.7 12.6 13.6 14.5 5.06 8.8 9.7 10.6 11.5 12.5 5.23 6.7 7.6 8.6 9.5 10.4 5.40 12.5 13.4 14.3 15.2 16.1* 5.09 10.6 11.5 12.5 13.4 14.3 5.25 8.6 9.5 10.5 11.4 12.3 5.42 6.5 7.5 8.4 9.3 10.2 5.59 12.3 13.2 14.1 15.0 15.8* 5.31 10.5 11.4 12.3 13.2 14.1 5.47 8.4 9.3 10.3 11.2 12.1 5.63 6.4 7.3 8.2 9.1 10.0 5.79 12.1 13.0 13.9 14.9 15.5* 5.53 10.3 11.2 12.1 13.0 13.9 5.68 8.3 9.2 10.1 11.0 11.9 5.84 6.2 7.1 8.0 8.9 9.9 6.00 11.7 12.7 13.6 14.5* 14.8* 5.98 9.9 10.8 11.7 12.7 13.6 6.12 7.9 8.8 9.7 10.6 11.6 6.26 5.8 6.7 7.7 8.6 9.5 6.41 CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED) AIRFLOW 1525 1975 AIRFLOW 1525 1975 TOTAL CAP. X0.98 X1.01 SENS. CAP. X0.94 X1.04 COMPR. KW X0.98 X1.01 VALUES AT 95/80/67 RATING CONDITIONS VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY = 14.6 KW AIRFLOW = 3056 CMH COMPRESSOR POWER = 4202 WATTS I.D. FAN POWER = 730 WATTS O.D. FAN POWER = 202 WATTS EER = 9.75 BTU/WATT GROSS CAPACITY = 14.6 KW AIRFLOW = 3056 CMH COMPRESSOR POWER = 4202 WATTS I.D. FAN POWER = 730 WATTS O.D. FAN POWER = 202 WATTS EER = 9.75 BTU/WATT NOTE: RATED WITH 7.62 METERS OF 1-1/8 IN. SUCTION AND 3/8 IN. LIQUID LINES NOTE: RATED WITH 7.62 METERS OF 1-1/8 IN. SUCTION AND 3/8 IN. LIQUID LINES * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL ALL TEMPERATURES IN DEGREES F TWE5-PRC000-EN 19 Performance Data Evaporator Fan Performance BLOWER PERFORMANCE — TWE030CA40B — WET COIL EXTERNAL STATIC PRESSURE INCHES OF WATER (PASCALS) UPFLOW & DOWNFLOW (See Notes) HORIZONTAL; NO FILTER (See Notes) 220 VOLTS 220 VOLTS Hl MED LO Hl MED LO 0.72 (179.4) 0.71 (176.9) 0.62 (154.4) 0.61 (152.0) 0.86 (214.2) 0.51 (127.0) 0.84 (209.2) 0.50 (124.6) 0.75 (186.8) 0.40 (99.6) 0.72 (179.4) 0.39 (97.1) (221.7) 0.65 (161.9) 0.29 (72.2) 0.87 (216.7) 0.62 (154.4) 0.28 (69.7) (201.8) 0.54 (134.5) 0.18 (44.8) 0.79 (196.8) 0.51 (127.0) 0.17 (42.3) (179.4) 0.43 (107.1) 0.06 (14.9) 0.69 (171.9) 0.40 (99.6) 0.08 (19.9) (156.9) 0.32 (79.7) 0.61 (152.0) 0.30 (74.7) (132.0) 0.21 (52.3) 0.51 (127.0) 0.17 (42.3) (104.6) 0.10 (24.9) 0.40 (99.6) 0.02 (5.0) (77.2) 0.31 (77.2) (49.8) 0.22 (54.8) (19.9) 0.10 (24.9) CFM CMH 600 1018.8 650 1103.7 700 1188.6 750 1273.5 800 1358.4 0.89 850 1443.3 0.81 900 1528.2 0.72 950 1613.1 0.63 1000 1698.0 0.53 1050 1782.9 0.42 1100 1867.8 0.31 1150 1952.7 0.20 1200 2037.6 0.08 NOTES: Vertical: With filter, no horizontal drip tray. Subtract 0.06" W.G. for downflow. Horizontal: As shipped, but without filter. Subtract 0.05" W.G. for horizontal left. BLOWER PERFORMANCE — TWE040CA40C — WET COIL EXTERNAL STATIC PRESSURE INCHES OF WATER (PASCALS) UPFLOW & DOWNFLOW (See Notes) HORIZONTAL; NO FILTER (See Notes) 220 VOLTS 220 VOLTS Hl MED LO Hl MED LO 0.58 (144.5) 0.61 (152.0) 0.55 (137.0) (152.0) 0.58 (144.5) 0.52 (129.5) 0.58 (144.5) (142.0) 0.54 (134.5) 0.48 (119.6) 0.52 (129.5) (132.0) 0.51 (127.0) 0.44 (109.6) 0.49 (122.1) (122.1) 0.47 (117.1) 0.40 (99.6) 0.57 (142.0) 0.45 (112.1) (112.1) 0.43 (107.1) 0.34 (84.7) 0.53 (132.0) 0.50 (124.6) 0.40 (99.6) (99.6) 0.38 (94.7) 0.28 (69.7) 0.48 (119.6) 0.45 (112.1) 0.35 (87.2) (89.7) 0.34 (84.7) 0.22 (54.8) 0.43 (107.1) 0.40 (99.6) 0.30 (74.7) (77.2) 0.29 (72.2) 0.15 (37.4) 0.39 (97.1) 0.37 (92.2) 0.22 (54.8) (64.8) 0.24 (59.8) 0.08 (19.9) 0.35 (87.2) 0.32 (79.7) 0.17 (42.3) (52.3) 0.18 (44.8) 0.00 (0.0) 0.31 (77.2) 0.28 (69.7) 0.10 (24.9) (42.3) 0.13 (32.4) 0.26 (64.8) 0.22 (54.8) 0.01 (2.5) (27.4) 0.07 (17.4) 0.21 (52.3) 0.18 (44.8) (14.9) 0.01 (2.5) 0.15 (37.4) 0.12 (29.9) (2.5) 0.11 (27.4) 0.08 (19.9) 0.05 (12.5) 0.02 (5.0) CFM CMH 700 1188.6 750 1273.5 800 1358.4 0.61 850 1443.3 0.57 900 1528.2 0.53 950 1613.1 0.49 1000 1698.0 0.45 1050 1782.9 0.40 1100 1867.8 0.36 1150 1952.7 0.31 1200 2037.6 0.26 1250 2122.5 0.21 1300 2207.4 0.17 1350 2292.3 0.11 1400 2377.2 0.06 1450 2462.1 0.01 1500 2547.0 0.00 NOTES: Vertical: With filter, no horizontal drip tray. Small apex baffle. Subtract 0.06" W.G. for downflow. Horizontal: As shipped, but without filter. Subtract 0.05" W.G. for horizontal left. 20 TWE5-PRC000-EN Performance Data BLOWER PERFORMANCE — TWE050CA50D — WET COIL EXTERNAL STATIC PRESSURE INCHES OF WATER (PASCALS) UPFLOW & DOWNFLOW (See Notes) HORIZONTAL; NO FILTER (See Notes) 220 VOLTS 220 VOLTS MED LO Hl MED CFM CMH Hl 900 1528.2 950 1613.1 0.63 1000 1698.0 0.61 1050 1782.9 0.58 1100 1867.8 0.54 1150 1952.7 0.50 1200 2037.6 0.45 1250 2122.5 0.61 (152.0) 0.39 1300 2207.4 0.59 (147.0) 0.57 (142.0) 0.33 1350 2292.3 0.56 (139.5) 0.53 (132.0) 0.26 1400 2377.2 0.52 (129.5) 0.49 (122.1) 0.18 1450 2462.1 0.48 (119.6) 0.45 (112.1) 0.10 1500 2547.0 0.44 (109.6) 0.40 (99.6) 0.01 1550 2631.9 0.40 (99.6) 0.35 (87.2) 1600 2716.8 0.35 (87.2) 0.30 (74.7) 1650 2801.7 0.31 (77.2) 0.25 (62.3) 1700 2886.6 0.26 (64.8) 0.20 (49.8) 1750 2971.5 0.21 (52.3) 0.14 (34.9) 1800 3056.4 0.16 (39.9) 0.08 (19.9) 1850 3141.3 0.11 (27.4) 0.02 (5.0) 1900 3226.2 0.05 (12.5) 1950 3311.1 NOTES: Vertical: With filter, no horizontal drip tray. Small apex baffle Subtract 0.06" W.G. for downflow. Horizontal: As shipped, but without filter. Subtract 0.05" W.G for horizontal left. TWE5-PRC000-EN (156.9) (152.0) (144.5) (134.5) (124.6) (112.1) (97.1) (82.2) (64.8) (44.8) (24.9) (2.5) 21 0.62 0.59 0.56 0.52 0.49 0.47 0.45 0.41 0.36 0.30 0.24 0.17 0.10 0.02 (154.4) (147.0) (139.5) (129.5) (122.1) (117.1) (112.1) (102.1) (89.7) (74.7) (59.8) (42.3) (24.9) (5.0) 0.64 0.61 0.58 0.55 0.52 0.48 0.44 0.40 0.35 0.28 0.20 0.13 0.07 0.01 (159.4) (152.0) (144.5) (137.0) (129.5) (119.6) (109.6) (99.6) (87.2) (69.7) (49.8) (32.4) (17.4) (2.5) LO 0.62 0.60 0.57 0.53 0.49 0.44 0.38 0.32 0.25 0.18 0.11 0.00 (154.4) (149.5) (142.0) (132.0) (122.1) (109.6) (94.7) (79.7) (62.3) (44.8) (27.4) (0.0) Performance Data Air Pressure Drop (Inches) - Electric Heaters PRESSURE DROP FOR ELECTRIC HEATERS IN AIR HANDLER MODELS 1 2 NUMBER OF RACKS 3 AIR PRESSURE DROP IN. W.G. (PASCALS) (5.0) 0.02 (5.0) (5.0) 0.02 (5.0) (7.5) 0.03 (7.5) (7.5) 0.04 (10.0) (10.0) 0.05 (12.5) (12.5) 0.06 (14.9) (14.9) 0.07 (17.4) (17.4) 0.08 (19.9) (19.9) 0.10 (24.9) (22.4) 0.11 (27.4) (24.9) 0.12 (29.9) (27.4) 0.14 (34.9) (32.4) 0.16 (39.9) (37.4) 0.18 (44.8) (42.3) 0.20 (49.8) 4 AIRFLOW AIRFLOW CFM CMH 600 1018.8 0.01 (2.5) 0.02 700 1188.6 0.01 (2.5) 0.02 800 1358.4 0.02 (5.0) 0.03 0.04 (10.0) 900 1528.2 0.03 (7.5) 0.03 0.05 (12.5) 1000 1698.0 0.04 (10.0) 0.04 0.06 (14.9) 1100 1867.8 0.04 (10.0) 0.05 0.07 (17.4) 1200 2037.6 0.05 (12.5) 0.06 0.08 (19.9) 1300 2207.4 0.06 (14.9) 0.07 0.09 (22.4) 1400 2377.2 0.07 (17.4) 0.08 0.11 (27.4) 1500 2547.0 0.08 (19.9) 0.09 0.13 (32.4) 1600 2716.8 0.09 (22.4) 0.10 0.15 (37.4) 1700 2886.6 0.10 (24.9) 0.11 0.17 (42.3) 1800 3056.4 0.11 (27.4) 0.13 0.19 (47.3) 1900 3226.2 0.13 (32.4) 0.15 0.21 (52.3) 2000 3396.0 0.14 (34.9) 0.17 0.23 (57.3) NOTES: 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. 5 0.08 0.09 0.11 0.13 0.15 0.17 0.19 0.21 0.23 0.26 (19.9) (22.4) (27.4) (32.4) (37.4) (42.3) (47.3) (52.3) (57.3) (64.8) HEATER RACKS HEATER NO. OF MODEL NO. RACKS BAY96X1405 1 BAY96X1406 2 BAY96X1408 2 BAY96X1410 2 BAY96X1411 3 BAY96X1415 3 BAY96X1419 4 BAY96X1421 4 BAY96X1426 5 BAY96X3411 3 BAY96X3415 3 22 TWE5-PRC000-EN Supplementary Heaters THESE AIR HANDLERS ARE CONVERTIBLE AND MOTOR SPEED TAPS VARY BY THE UNIT ORIENTATION. TWE030C-HEATER MODEL NUMBER BAY96X Unit 1405 1406 1408,F 1410,F 1410A 1411 1411A 1415 1419 1421 3411 Position Application 4.0 KW 4.8 KW 6.4 KW 8.0 KW 8.8 KW 8.8 KW 8.8 KW 12.8 KW 16.0 KW 17.6 KW 8.8 KW Vertical A/C or Elec. Furnace L L L L L L L L L L L Upflow Heat Pump L L L L L L L L M M L Vertical A/C or Elec. Furnace L L L L L L L L L L L Downflow Heat Pump L L L L L L L L H H L Horizontal A/C or Elec. Furnace L L L L L L L L L L L Left Heat Pump L L L L L L L L M M L Horizontal A/C or Elec. Furnace L L L L L L L L L L L Right Heat Pump L L L L L L L L H H L (L) Low, (M) Medium, (H) High indicate minimum heating speed setting for blower/motor operation. 1414 and 1426 not approved for this model. 3415 12.8 KW L L L H L L L L TWE040C-HEATER MODEL NUMBER BAY96X Unit 1405 1406 1408,F 1410,F 1410A 1411 1411A 1415 1419 1421 Position Application 4.0 KW 4.8 KW 6.4 KW 8.0 KW 8.8 KW 8.8 KW 8.8 KW 12.8 KW 16.0 KW 17.6 KW Vertical A/C or Elec. Furnace L L L L L L L L L L Upflow Heat Pump L L L L L M M H H H Vertical A/C or Elec. Furnace L L L L L L L L L L Downflow Heat Pump L L L L L L L H H H Horizontal A/C or Elec. Furnace L L L L L L L L L L Left Heat Pump L L L L L L L H H H Horizontal A/C or Elec. Furnace L L L L L L L L L L Right Heat Pump L L L L L L L H H H (L) Low, (M) Medium, (H) High indicate minimum heating speed setting for blower/motor operation. 1414 not approved for this model. 3411 8.8 KW L M L L L L L L 3415 12.8 KW L M L L L L L L TWE050C-HEATER MODEL NUMBER BAY96X Unit 1405 1406 1408,F 1410,F 1410A 1415 1419 1421 1426 Position Application 4.0 KW 4.8 KW 6.4 KW 8.0 KW 8.8 KW 12.8 KW 16.0 KW 17.6 KW 21.6 KW Vertical A/C or Elec. Furnace — — L L L L L L L Upflow Heat Pump L L L L L L M M H Vertical A/C or Elec. Furnace — — L L L L L L L Downflow Heat Pump L L L L L L H H H Horizontal A/C or Elec. Furnace — — L L L L L L L Left Heat Pump L L L L L L H H H Horizontal A/C or Elec. Furnace — — L L L L L L L Right Heat Pump L L L L L L M M H (L) Low, (M) Medium, (H) High indicate minimum heating speed setting for blower/motor operation. 14141,A & 1414 not approved for this model. TWE5-PRC000-EN 23 3415 12.8 KW L L L L L L L L 24 3. A 220V HIGH VOLTAGE CONTROL IN TTB5-C NEEDS TO BE CHANGED WITH 24V LOW VOLTAGE CONTROL KIT (ACYLVCR006A) WHEN MATCHED WITH TWE-C AIR HANDLING UNITS. 2. ACCESSORY KIT BAY24X038 MAY BE USED WHEN AUTOMATIC SPEED CHANGE FOR HEATING/COOLING OPERATION IS DESIRED. NOTES: 1. DO NOT USE REQ TRANSFORMER LEAD IN THIS APPLICATION System Wiring Diagram TWE5-PRC000-EN Dimensional Data TWE030-050C Outline Drawing All dimensions are in inches (mm) SIDES FRONT BACK INLET DUCT OUTLET DUCT MINIMUM UNIT CLEARANCE SALE TO COMBUSTIBLE SERVICE CLEARANCE MATERIAL (REQUIRED) (RECOMMENDED) 0 (0) 2 (50.8) 0 (0) 21 (533.4) 0 (0) 0 (0) 0 (0) 1 (25.4) 1 (25.4) TWE5-PRC000-EN MODEL NO. TWE030CA4 TWE040CA4 TWE050CA5 25 A 43.00 (1092.2) 51.75 (1134.5) 57.90 (1470.7) B 15.57 (395.5) 24.32 (617.7) 30.47 (773.9) C 21.50 (761.1) 23.50 (596.9) 23.50 (596.9) D 19.50 (495.3) 21.50 (761.1) 21.50 (761.1) E 20.28 (515.1) 22.28 (565.9) 22.28 (565.9) F 21.63 (549.4) 23.63 (600.2) 23.63 (600.2) FLOW CONTROL FCCV FCCV TXV Dimensional Data 1 INCH = (25.40 MILLIMETERS) TTB524-536CA Outline Drawing All dimensions are in inches (mm) PT. NO. TTB524CA TTB530CA/ TTB536CA CABINET SIZE 25A 25C A 251/2 (648) 321/2 (826) B 11/16 14 UNS-2A 11/16 14 UNS-2A C /2 20UNF-2A 1 /2 20UNF-2A 1 D /4 (19 3 /4 (19) 3 E /16 (8) 5 /16 (8) 5 FLARE NUT TORQUE TORQUE FT-LBS (NEWTON METERS) APPLIED TUBE SIZE MINIMUM MAXIMUM 1 /4 (6.35) 8 (11.0) 10 (14.0) 5 /16 (7.94) 10 (14.0) 15 (20.0) 3 /8 (9.52) 15 (20.0) 25 (34.0) 1 /2 (12.70) 25 (34.0) 35 (47.0) 5 /8 (15.88) 40 (54.0) 55 (75.0) 3 /4 (19.05) 50 (68.0) 60 (81.0) BACK-UP HEX SIZE 1 1/16-14 = 1 1/16 (27) 1 /2-20 = 1/2 (13) SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENTS CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305 (12”) FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. “C” SAE MALE FLARE FOR “E” O.D. TUBE SIZE CONNECTION WITH 1/4” SAE FLARE PRESSURE TAP FITTING. 26 “B” SAE MALE FLARE FOR “D” O.D. TUBE SIZE CONNECTION WITH 1/4” SAE FLARE PRESSURE TAP FITTING. TWE5-PRC000-EN Dimensional Data TTA030-060C Outline Drawing All dimensions are in inches (mm) TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST FIVE (5) FEET ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 12” (305) FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. FIG. 1 FIG. 2 TWE5-PRC000-EN 27 MODEL TTA030C Figure 1 TTA040C 1 TTA050C 2 TTA060C 2 A 24 3/8 (619.1) 32 3/4 (831.9) 40 5/8 (1031.9) 44 3/4 (1136.7) B 28 1/4 (714.4) 28 1/4 (714.4) 32 7/8 (835.0) 38 7/8 (987.4) C 24 5/8 (625.5) 24 5/8 (625.5) 28 3/4 (730.3) 34 3/4 (882.7) D /8 (22.2) 1 1/8 (28.6) 1 1/8 (28.6) 1 1/8 (28.6) 7 E /8 (9.53) 3 /8 (9.53) 3 /8 (9.53) 3 /8 (9.53) 3 Dimensional Data TWE030 Through 050 Convertibility Six (6) Way Convertibility One Unit - 4 Applications Easy Conversion to Opposite Side Access 28 TWE5-PRC000-EN Mechanical Specifications General Blower coil units shall be completely factory assembled including coil, condensate drain pan, fan, motor, filters and controls in an insulated casing that can be applied in horizontal or vertical configuration. This new line of TWE-C air handlers provides exclusive compact size combined with simple four-way convertibility in three sizes. The unit ships in the right hand horizontal configuration and converts to vertical upflow just by standing the unit on end. No tools required. Simple coil rotation provides downflow and horizontal left applications. The four-way convertibility provides you inventory benefits and service/ installation flexibility. The simple conversion provides opposite side access for installation and service. Casing Units shall have rugged sheet metal and steel frame construction and shall be painted with an enamel finish. Casing shall be insulated and knockouts shall be provided for electrical power and control wiring. Refrigerant Circuits The TWE units shall have a single refrigerant circuit. TWE03-040C refrigerant circuit shall be controlled by a flow control check valve (FCCV). The TWE050C refrigerant circuit shall be controlled by a factory-installed thermal expansion valve. TWE5-PRC000-EN 29 Coil Aluminum fin surface shall be mechanically bonded to 3/8-inch OD copper tubing. Coils shall be factory pressure and leak tested. Fan Forward curved, dynamically and statically balanced with three-speed direct drive shall be standard, fan motor bearing shall be permanently lubricated. Controls Fan contactor, and plug-in module for accessory electric heat control shall be included. TWE models shall also include check valves. Filters Filters shall be included as standard. Accessories Electric Heaters — Shall be available in a wide range of capacities and voltages with various staging options and plug in control wiring. Heaters shall fit inside internal compartment. The Trane Company International Unitary Products Group 3600 Pammel Creek Road La Crosse, WI 54601-7599 www.trane.com An American Standard Company File No. Supersedes Stocking Location TWE5-PRC000-EN 4/99 TWE5-PRC000-EN 2/98 La Crosse Since The Trane Company has a policy of continuous product improvement, it reserves the right to change design and specification without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 2000:04:20 08:52:39 Producer : Acrobat Distiller 4.05 for Windows Modify Date : 2000:06:12 16:52:26-05:00 Title : Insight ™ Ducted Air Handler Cooling Only Split System Air Conditioning , 30 to 50 MBh, PDF Product Catalog (TWE5-PRC000-EN) Page Count : 30EXIF Metadata provided by EXIF.tools