Trane 4Twb4 Users Manual 22 1834 09 02/01/2012 Product Data SPLIT SYSTEM HEAT PUMP 1 1/2 ? 5 TON XB14

4TWB4 to the manual b97b3716-aff4-4515-9253-7aa5778c0cb5

2015-01-21

: Trane Trane-4Twb4-Users-Manual-236222 trane-4twb4-users-manual-236222 trane pdf

Open the PDF directly: View PDF PDF.
Page Count: 16

DownloadTrane Trane-4Twb4-Users-Manual- 22-1834-09 02/01/2012 Product Data SPLIT SYSTEM HEAT PUMP 1 1/2 ? 5 TON - XB14 4TWB4  Trane-4twb4-users-manual
Open PDF In BrowserView PDF
Split System
Heat Pump
Product Data
XB14	4TWB4	
1 1/2 - 5 Tons

PUB. NO. 22-1834-09

Features and
Benefits

•	 CLIMATUFF® compressor
• 	Efficiency up to 16.0 SEER and
8.5 HSPF
• 	All aluminum SPINE FIN™ coil
• 	WEATHERGUARD™ fasteners
• 	QUICK-SESS™ cabinet,
service access and refrigerant
connections with full coil
protection
• 	DURATUFF™ base, fast complete
drain, weatherproof
• 	COMFORT-R™ mode approved
• 	Glossy corrosion resistant finish
• 	Internal compressor high/low
pressure & temperature protection
• 	018, 024, 030, 060 & 061 ship
with start kit
• 	Compressor Sump Heat

© 2012 Trane	

2	

• 	Liquid line filter/drier
• 	Polyslate gray cabinet with
anthracite gray badge
• 	High pressure switch
• 	Demand Defrost with Diagnostics
• 	R-410A refrigerant
• 	S.E.E.T. design testing
• 	100% line run test
• 	Low ambient cooling to 20°F with
AY28X084
• 	Low ambient cooling to 55°F as
shipped
• 	Extended warranties available

22-1834-09

Contents
Features and Benefits	

2

General Data	

4

Product Specifications	
A-weighted Sound Power Level [dB(A)]	
Accessory Description and Usage	
AHRI Standard Capacity Rating Conditions	

4
4
6
6

Model Nomenclature	
7
Electrical Data	
8
Dimensions	15
Mechanical ­Specification Options	
16

22-1834-09	3

General
Data
Product Specifications
Model No. 1	
4TWB4018G1	4TWB4024G1	4TWB4030G1	4TWB4036G1
Electrical Data V/Ph/Hz 2	
208/230/1/60	208/230/1/60	208/230/1/60	208/230/1/60
Min Cir Ampacity	
9	
11	
15	
18
Max Fuse Size (Amps)	
15	
15	
25	
30
Compressors	CLIMATUFF®	CLIMATUFF®	CLIMATUFF®	CLIMATUFF®
RL AMPS - LR AMPS	
6.4 - 38.6	
8.3 - 58	
11.3 - 68.2	
13.2 - 63
Outdoor Fan FL Amps	
0.70	
0.74	
0.92	
1.00
Fan HP	
1/8	1/8	1/5	1/5
Fan Dia (inches)	
23	
23	
27.5	
27.5
Coil	
Spine Fin™	
Spine Fin™	
Spine Fin™	
Spine Fin™
Refrigerant R-410A	5/14-LB/OZ	7/02-LB/OZ	8/02-LB/OZ	7/13-LB/OZ
Line Size - (in.) O.D. Gas 3	
5/8	5/8	3/4	3/4
Line Size - (in.) O.D. Liquid 3	
3/8	3/8	3/8	3/8
Dimensions H x W x D (Crated)	
34 x 30.1 x 33	
38 x 30.1 x 33	
38.4 x 35.1 x 38.7	
37.9 x 35 x 37.9
Weight - Shipping	
204	
236	
273	
261
Weight - Net	
176	
208	
239	
227
Start Components	
YES	YES	YES	YES
Sound Enclosure	
NO	NO	NO	YES
Compressor Sump Heat	
NO	
NO	
NO	
NO
Optional Accessories: 4
Anti-short Cycle Timer	
TAYASCT501A	TAYASCT501A	TAYASCT501A	TAYASCT501A
Evaporator Defrost Control A/C	
AY28X084	
AY28X084	
AY28X084	
AY28X084
Rubber Isolator Kit	
BAYISLT101	
BAYISLT101	
BAYISLT101	
BAYISLT101
Crankcase Heater	 BAYCCHT300	BAYCCHT300	BAYCCHT300	BAYCCHT300	
Extreme Condition Mounting Kit	 BAYECMT004	
BAYECMT004	
BAYECMT004	
BAYECMT004
Snow Leg - Base & Cap 4" High	 BAYLEGS002	
BAYLEGS002	
BAYLEGS002	
BAYLEGS002
Snow Leg - 4" Extension	
BAYLEGS003	
BAYLEGS003	
BAYLEGS003	
BAYLEGS003
Seacoast Kit	
BAYSEAC001	BAYSEAC001	BAYSEAC001	BAYSEAC001
Refrigerant Lineset 5	TAYREFLN950	 TAYREFLN950	 TAYREFLN7*	 TAYREFLN7*
1	 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.
2	 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3	 Standard line lengths - 80'. Standard lift - 60' Suction and Liquid line.
	 For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision)
4	 For accessory description and usage, see page 5.
5	 * = 15, 20, 25, 30, 40 and 50 foot lineset available.

A-weighted Sound Power Level [dB(A)]

MODEL

SOUND POWER
LEVEL [dB(A)]

4TWB4018G

A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] High Stage
63

125

250

500

1000

2000

4000

8000

76

52.3

57.8

62.4

67.2

69.4

67.2

59.6

52.5

4TWB4024G

76

50.3

55

58.6

65.3

69.5

64.5

58.6

50.8

4TWB4030G

76

48.8

55.4

60.1

66.4

67.4

63.9

60.2

53.5

4TWB4036G

76

54.5

55.1

58.3

67

69.8

65.9

59.7

49.1

4TWB4042E

78

55.1

52

59.3

64.9

67.2

63.5

60.4

47.6

4TWB4048E

78

55.6

53.3

59.2

66.7

71.7

67.9

60.7

51.3

4TWB4049E

76

43.7

51.2

54.5

61

61.5

57.1

51.3

40.7

4TWB4060E

78

55.1

53.7

61.1

69.2

73.6

68.7

61.4

50

4TWB4061E

76

31.9

58.9

57.1

64.8

66.4

59.8

55.9

51.2

Note: Rated in accordance with AHRI Standard 270-2008.
	

4	22-1834-09

General
Data
Product Specifications
Model No. 1	
4TWB4042E1	 4TWB4048E1	 4TWB4049E1	
4TWB4060E1	4TWB4061E1	
Electrical Data V/Ph/Hz 2	 208/230/1/60	 208/230/1/60	 208/230/1/60	
208/230/1/60	208/230/1/60
Min Cir Ampacity	
27	
29	
28	
35	
36	
Max Fuse Size (Amps)	
45	
50	
50	
60	
60
Compressors	
CLIMATUFF® - SCROLL	CLIMATUFF® - SCROLL	CLIMATUFF® - SCROL	CLIMATUFF® - SCROLL	CLIMATUFF® - SCROL	
RL AMPS - LR AMPS	
19.9 - 109	
21.8 - 117	
21.8 - 117	
26.4 - 134	
26.4 - 134	
Outdoor Fan FL Amps	
0.93	
0.93	
1.00	
0.93	
2.80	
Fan HP	
1/5	
1/5	
1/5	
1/5	
1/3
Fan Dia (inches)	
27.6	
27.6	
27.6	
27.6	
27.6	
Coil	
Spine Fin™	
Spine Fin™	
Spine Fin™	
Spine Fin™	
Spine Fin™
Refrigerant R-410A	
12/1-LB/OZ	
13/9-LB/OZ	
13/10-LB/OZ	
12/1-LB/OZ	
13/12-LB/OZ
Line Size - (in.) O.D. Gas 3	3/4	
7/8	
7/8	
7/8	 1-1/8
Line Size - (in.) O.D. Liquid 3	3/8	
3/8	
3/8	
3/8	
3/8
Dimensions H x W x D (Crated)	 46.4 x 35.1 x 38.7	
51 x 35.1 x 38.7	
51 x 35.1 x 38.7	
51 x 35.1 x 38.7	
51 x 35.1 x 38.7
Weight - Shipping	
313	
331	
331	
332	
332
Weight - Net	
277	
294	
294	
295	
295
Start Components	
NO	
NO	
NO	
YES	
YES
Sound Enclosure	
NO	
NO	
NO	
NO	
NO
Compressor Sump Heat	
YES	
YES	
YES	
YES	
YES
Optional Accessories: 4
Anti-short Cycle Timer	
TAYASCT501A	
TAYASCT501A	
TAYASCT501A	
TAYASCT501A	
TAYASCT501A
Evaporator Defrost Control A/C	
AY28X084	
AY28X084	
AY28X084	
AY28X084	
AY28X084
Rubber Isolator Kit	
BAYISLT101	
BAYISLT101	
BAYISLT101	
BAYISLT101	
BAYISLT101
Hard Start Kit Scroll	
BAYKSKT260	
BAYKSKT260	
BAYKSKT260		
Extreme Condition Mounting Kit	 BAYECMT004	
BAYECMT004	
BAYECMT004	
BAYECMT004	
BAYECMT004
Snow Leg - Base & Cap 4" High	 BAYLEGS002	
BAYLEGS002	
BAYLEGS002	
BAYLEGS002	
BAYLEGS002
Snow Leg - 4" Extension	
BAYLEGS003	
BAYLEGS003	
BAYLEGS003	
BAYLEGS003	
BAYLEGS003
Seacoast Kit	
BAYSEAC001	
BAYSEAC001	
BAYSEAC001	
BAYSEAC001	
BAYSEAC001
Refrigerant Lineset 5	
TAYREFLN7*	 TAYREFLN3*	 TAYREFLN3*	
TAYREFLN3*	TAYREFLN3*
1	 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.
2	 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3	 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line.
	 For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision)
4	 For accessory description and usage, see page 5.
5	 * = 15, 20, 25, 30, 40 and 50 foot lineset available.

22-1834-09	

5

General
Data
Accessory Description and Usage

AHRI Standard Capacity Rating Conditions

Anti-Short Cycle Timer — Solid state timing device that
prevents compressor recycling until 5 minutes have elapsed
after satisfying call or power interruptions. Use in area with
questionable power delivery, commercial applications, long
lineset, etc.

AHRI STANDARD 210/240 RATING CONDITIONS —
(A)	 Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil.
AHRI STANDARD 270 RATING CONDITIONS — (Noise
rating numbers are determined with the unit in cooling operation.) ­Standard Noise Rating number is at 95°F outdoor air.

Evaporator Defrost Control — SPST Temperature actuated
switch that cycles the condenser off as indoor coil reaches
freeze-up conditions. Used for low ambient cooling to 30°F
with TXV.
Rubber Isolators — 5 large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or
pad. Use on any application where sound transmission needs
to be minimized.
Hard Start kit — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply,
on long linesets, low ambient conditions, etc.
Extreme Condition Mount Kit — Bracket kits to securely
mount condensing unit to a frame or pad without removing
any panels. Use in areas with high winds, or on commercial
roof tops, etc. 

	

6	

22-1834-09

Model
Nomenclature
Outdoor Units

Gas Furnaces

4 T W B 4 0 3 6 G 1 0 0 0 A A

T U D 2 B 0 8 0 A C V 3 2 A A

Refrigerant Type
2 = R-22
4 = R-410A
TRANE
Product Type
W = Split Heat Pump
T = Split Cooling
Product Family
Z = Leadership – Two Stage
X = Leadership
R = Replacement/Retail
B = Basic
A = Light Commercial
Family SEER
0 = 10
3 = 13
1 = 11
4 = 14
2 = 12
5 = 15

6 = 16
8 = 18
9 = 19

Split System Connections 1-6 Tons
0 = Brazed
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply
1 = 200-230/1/60 or 208-230/1/60
3 = 200-230/3/60
4 = 460/3/60
Secondary Function
Minor Design Modifications
Unit Parts Identifier

Air Handlers –
Residential

4 T E E 3 F 3 6 A 1 0 0 0 A A

Coils –
Residential

Refrigerant Type
4 = R-410A

T

X

C

B

0

0

Refrigerant Type
4 - R410A

Application
TE = Fully Convertible
TG = Semi Convertible
TF = Front Return

Product Family
T-Premium
(Heat Pump or Convertible Coil)
Coil Design
X - Direct Expansion Evaporator Coil

Product Family
E = Leadership – Variable Speed
P = Leadership
C = Replacement/Retail
B = Basic
Flow Control
0 = No Flow Control
3 = Nonbleed TXV
Feature Identifier
0 = Standard Unit
F = Air-Tite™
Nominal Capacity in 1000’s (BTUH)
Major Design Change
Power Supply
1 = Single Phase
Electrical Connection
0 = Pig Tails
B = Circuit Breaker
D = Pull Disconnect
Future Option – Factory Installed Heater Nominal KW Value
Minor Design Modifications
Unit Parts Identifier
NOTE: There will be a phase-in of new model numbers for new
air handlers over next 2 years.

Product Family
C - Cased A Coil
A - Uncased A Coil
F - Cased Horizontal Flat Coil
Coil Width (Cased/Uncased)
A - 14.5" / 13.3"
B - 17.5" / 16.3"
C - 21.0" / 19.8"
D - 24.5" / 23.3"
H - 10.5"
Refrigerant Line Coupling
0 - Brazed
Model Number Distinguisher
Major Design Change
Efficiency
C - Standard
S - Hi Efficiency (Derived from 10 SEER products)
Refrigerant Control
3 - TXV - Non-Bleed
Coil Circuitry
H - Heat Pump
Airflow Configuration
A - Upflow Only
U - Upflow / Downflow
H - Horizontal Only
C - Convertible - Upflow, Downflow, Left or Right Airflow
Minor Design Change
Unit Parts Identifier

22-1834-09	

4

7

1

C

C

3

H

C

A

A

Electrical
Data
Schematic Diagrams
4TWB4018, 4TWB4024, 4TWB4036

Printed from D156770P01 Rev 00

	

8	22-1834-09

Electrical
Data
Schematic Diagrams
4TWB4030

Printed from D157099P01

22-1834-09	9

Electrical
Data
Schematic Diagrams

4TWB4042

TDR relay cycles sump heat off during compressor operation and delays
energizing the sump heat for 30 mins
after “Y” call is removed.

Printed from D156131P02 Rev 00

	10	22-1834-09

Electrical
Data
Schematic Diagrams

4TWB4048

TDR relay cycles sump heat off during compressor operation and delays
energizing the sump heat for 30 mins
after “Y” call is removed.

Printed from D156128P02 Rev 00

22-1834-09	11

Electrical
Data
Schematic Diagrams
(SEE LEGEND)

4TWB4049E

TDR relay cycles sump heat off during compressor operation and delays
energizing the sump heat for 30 mins
after “Y” call is removed.

PRINTED FROM D156976P01 REV. 00

	12	22-1834-09

Electrical
Data
Schematic Diagrams

4TWB4060

TDR relay cycles sump heat off during compressor operation and delays
energizing the sump heat for 30 mins
after “Y” call is removed.

Printed from D156129P02 Rev 00

22-1834-09	13

Electrical
Data
Schematic Diagrams
(SEE LEGEND)

4TWB4061E

TDR relay cycles sump heat off during compressor operation and delays
energizing the sump heat for 30 mins
after “Y” call is removed.

PRINTED FROM D154974P02 REV. 00

	14	22-1834-09

Dimensions

4TWB4 Outline Drawing
Note: All dimensions are in MM (Inches).

MODELS

BASE

A

B

C

D

E

F

G

H

J

K

4TWB4018G

4

730 (28-3/4)

829 (32-5/8)

756 (29-3/4)

5/8

3/8

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)    79 (3-1/8)

508 (20)

4TWB4024G

3

832 (32-3/4)

829 (32-5/8)

756 (29-3/4)

5/8

3/8

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)    79 (3-1/8)

508 (20)

4TWB4030G

4

841 (33-1/8)

946 (37-1/4)

870 (34-1/4)

3/4

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)    86 (3-3/8)

508 (20)

4TWB4036G

4

841 (33-1/8)

946 (37-1/4)

870 (34-1/4)

3/4

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)    86 (3-3/8)

508 (20)

4TWB4042E

4

1045 (41 1/8)

946 (37-1/4)

870 (34-1/4)

3/4

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)    86 (3-3/8)

508 (20)

4TWB4048E

4

1147 (45 1/8)

946 (37-1/4)

870 (34-1/4)

7/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)    86 (3-3/8)

508 (20)

4TWB4049E

4

1147 (45 1/8)

946 (37-1/4)

870 (34-1/4)

7/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)    86 (3-3/8)

508 (20)

4TWB4060E

4

1147 (45 1/8)

946 (37-1/4)

870 (34-1/4)

7/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)    86 (3-3/8)

508 (20)

4TWB4061E

4

1147 (45 1/8)

946 (37-1/4)

870 (34-1/4)

1-1/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)    86 (3-3/8)

508 (20)

From Dwg. D156010
22-1834-09	

15

Mechanical
­Specification Options

General
The 4TWB4 is fully charged from the
factory for up to 15 feet of piping. This
unit is designed to operate at outdoor
ambient temperatures as high as 115°F.
Cooling capacities are matched with
a wide selection of air handlers and
furnace coils that are AHRI certified. The
unit is certified to UL 1995. Exterior is
designed for outdoor application.

Condenser Coil
The outdoor coil provides low airflow
resistance and efficient heat transfer.
The coil is protected on all four sides by
louvered panels.

Casing
Unit casing is constructed of heavy
gauge, G90 galvanized steel and
painted with a weather-resistant powder
paint
on all louvers, panels, prepaint on all
other panels. Corrosion and weatherproof CMBP-G30 DuraTuff™ base.

Accessories
Thermostats — Cooling only and heat/
cooling (manual and automatic changeover). Sub-base to match thermostat
and locking thermostat cover.

Low Ambient Cooling
As manufactured, this unit has a cooling capability to 55°F. The addition of
an evaporator defrost control with TXV
permits low ambient cooling to 20° F.

Refrigerant Controls
Refrigeration system controls include
condenser fan and compressor contactor.   High and low pressure controls are
inherent to the compressor. A factory
installed liquid line drier is standard.
Compressor
The Climatuff® compressor features
internal over temperature and pressure
protection and  total dipped hermetic
motor. Other features include: centrifugal
oil pump and low vibration and noise.

	

Trane
www.trane.com

02/12
	
	
Trane has a policy of continuous product and product data improvement and it reserves the right to change
design and specifications without notice.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 16
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:1aeb6a5f-d881-45c5-a7b9-888e22602964
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Acces flag                      : F
Alt order nbr                   : 
Alt order nbr type              : 
Bw color                        : B
Date published                  : 02/01/2012
Dept id                         : 54
Topic focused id                : EN|TRANE
Price                           : 0
Cur flag                        : T
Lit class id                    : PL
Lit length                      : 16
Lit order nbr                   : 22-1834-09
Lit type id                     : PRD
Media id                        : ELO
Model                           : NONE
Prod class                      : UN
Prod family id                  : 115
Prod                            : SSP
Topic related id                : TRN-FLD|STARTUP|RRR|OWN/DEV|OPER|INST|AMSTD
Restrct flag                    : F
Source date                     : nulldate
Source filename                 : 
Stocking loc id                 : None
Supceded by                     : 
Supceded by date                : nulldate
Unit flag                       : T
Branding                        : Trane
Lol language                    : EN
Object id                       : 090102b182bfb8b3
Object name                     : 22-1834-09_02012012
Chronicle id                    : 090102b181a33303
Filename                        : 82bfb8b3.pdf
Abstract                        :  Product Data  XB14 4TWB4 MODELS  1 1/5 - 5 Tons.
Hist model                      : 4TWB4018E1000A|4TWB4024E1000A|4TWB4030E1000A|4TWB4036E1000A|4TWB4042E1000A|4TWB4048E1000A|4TWB4060E1000A|4TWB4049E1000A|4TWB4049E1000AA|4TWB4061E1000A|4TWB4061E1000AA|4TWB4018G1000A|4TWB4018G1000AA|4TWB4024G1000AA|4TWB4030G1000A|4TWB4030G1000AA|4TWB4036G1000A|4TWB4036G1000AA|4TWB4042G1000AA
Create Date                     : 2012:02:17 15:09:05-06:00
Modify Date                     : 2012:02:20 16:51:55-06:00
Metadata Date                   : 2012:02:20 16:51:55-06:00
Creator Tool                    : Adobe InDesign CS5 (7.0.4)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 9210 bytes, use -b option to extract), (Binary data 5798 bytes, use -b option to extract)
Instance ID                     : uuid:acc09fbe-ac6d-4089-991c-2bc7a7275ecd
Document ID                     : xmp.did:1015C4B386EFE011AB12D8C63D6BB5EB
Rendition Class                 : proof:pdf
Original Document ID            : adobe:docid:indd:28c88d81-dc87-11df-9486-efde46b8063c
Derived From Instance ID        : xmp.iid:B831F04485EFE011AB12D8C63D6BB5EB
Derived From Document ID        : xmp.did:6A3D65B4C68BE011A90C8BA207EA7940
Derived From Original Document ID: adobe:docid:indd:28c88d81-dc87-11df-9486-efde46b8063c
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:C7D0EFD2E97BE01190FBFE56727BB48C, xmp.iid:C8D0EFD2E97BE01190FBFE56727BB48C, xmp.iid:A6E0758BEA7BE01190FBFE56727BB48C, xmp.iid:54C11949E27CE011953797CDA308AB91, xmp.iid:0B87D1AEE27CE011953797CDA308AB91, xmp.iid:8929EE9EE37CE011953797CDA308AB91, xmp.iid:57A55758C68BE011A90C8BA207EA7940, xmp.iid:6A3D65B4C68BE011A90C8BA207EA7940, xmp.iid:B4B5DD7DC98BE011A90C8BA207EA7940, xmp.iid:3DAE83E1C98BE011A90C8BA207EA7940, xmp.iid:E5DB0382508DE011BBA5C73A5461FB21, xmp.iid:B831F04485EFE011AB12D8C63D6BB5EB, xmp.iid:1015C4B386EFE011AB12D8C63D6BB5EB, xmp.iid:FE87F10E88EFE011AB12D8C63D6BB5EB, xmp.iid:F781DB518CEFE011AB12D8C63D6BB5EB, xmp.iid:AE79370394EFE011AB12D8C63D6BB5EB, xmp.iid:ED304EAF96EFE011AB12D8C63D6BB5EB, xmp.iid:1F9CD09CAB59E111B70FD38D1AC86D72
History When                    : 2011:05:11 11:15:01-05:00, 2011:05:11 11:15:01-05:00, 2011:05:11 11:20:11-05:00, 2011:05:12 16:56:25-05:00, 2011:05:12 16:56:25-05:00, 2011:05:12 17:03:08-05:00, 2011:05:31 15:43:56-05:00, 2011:05:31 15:43:56-05:00, 2011:05:31 16:03:53-05:00, 2011:05:31 16:06:40-05:00, 2011:06:02 14:42:54-05:00, 2011:10:05 14:17:43-05:00, 2011:10:05 14:17:44-05:00, 2011:10:05 14:27:26-05:00, 2011:10:05 14:57:56-05:00, 2011:10:05 15:53-05:00, 2011:10:05 16:12:08-05:00, 2012:02:17 15:09-06:00
History Software Agent          : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0
History Changed                 : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
N Pages                         : 16
Doc Change Count                : 272
Format                          : application/pdf
Title                           : 22-1834-09 02/01/2012 Trane Product Data SPLIT SYSTEM HEAT PUMP 1 1/2 ? 5 TON - XB14 - 4TWB4
Tagged PDF                      : Yes
Creator                         : Adobe InDesign CS5 (7.0.4)
Acces Flag                      : F
Alt Order Nbr                   : 
Alt Order Nbr Type              : 
Bw Color                        : B
Hist Model                      : 4TWB4018E1000A|4TWB4024E1000A|4TWB4030E1000A|4TWB4036E1000A|4TWB4042E1000A|4TWB4048E1000A|4TWB4060E1000A|4TWB4049E1000A|4TWB4049E1000AA|4TWB4061E1000A|4TWB4061E1000AA|4TWB4018G1000A|4TWB4018G1000AA|4TWB4024G1000AA|4TWB4030G1000A|4TWB4030G1000AA|4TWB4036G1000A|4TWB4036G1000AA|4TWB4042G1000AA
Date Published                  : 02/01/2012
Dept Id                         : 54
Topic Focused Id                : EN|TRANE
Cur Flag                        : T
Lit Class Id                    : PL
Lit Length                      : 16
Lit Order Nbr                   : 22-1834-09
Lit Type Id                     : PRD
Media Id                        : ELO
Prod Class                      : UN
Prod Family Id                  : 115
Topic Related Id                : TRN-FLD|STARTUP|RRR|OWN/DEV|OPER|INST|AMSTD
Restrct Flag                    : F
Source Date                     : nulldate
Source Filename                 : 
Stocking Loc Id                 : None
Supceded By                     : 
Supceded By Date                : nulldate
Unit Flag                       : T
Lol Language                    : EN
Object Id                       : 090102b182bfb8b3
Object Name                     : 22-1834-09_02012012
Chronicle Id                    : 090102b181a33303
EXIF Metadata provided by EXIF.tools

Navigation menu