TDD-D-1 Upflow/Horizontal Two-stage Condensing Gas-Fired Furnace XV 90 TUY060,080,100,120R9V Variable Speed Blower Variable Speed Inducer PUB. NO. 22-1682-05-0802 (EN) General Features NATURAL GAS MODELS Central heating furnace designs are certified by the International Approval Services (IAS) for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. AIR DELIVERY The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. SECONDARY HEAT EXCHANGER The XV 90 has a special type 29-4C™ stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost outside. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multi-port In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier. CONDENSATE DRAIN Built-in trap which can drain from either side when the furnace is installed upflow. © 2002 American Standard Inc. All Rights Reserved 2 STYLING Heavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection in vertical position. FEATURES AND GENERAL OPERATION The XV 90 High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter. b. Vent proving differential switch. Pub. No. 22-1682-05-0802 (EN) Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data 6 TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V Performance Data Pub. No. 22-1682-05-0802 (EN) 7 Electrical Data 11 Field Wiring 12 Dimensions 15 3 Features and Benefits XV 90 STANDARD EQUIPMENT • Variable speed indoor blower • Silicon Nitride Igniter with adaptive heat up • Variable speed induced draft blower • Direct/Non-Direct vent option • Fused 24 volt control circuit • Manual reset burner safety switches • Power supply 115/1/60 • Convertible to horizontal on left side • 2-stage gas valve • PVC venting-1 or 2 pipe option • Accessory hook-up capability • Integrated solid state control with self-diagnostics • Attractive color accents • Heavy gauge aluminized steel heat exchanger • Multi-port In-shot burners 4 • HInged blower door • Perfect fit door latches • Insulated blower door • Gasketed blower door • Internal filter rack • Standard filter sizes • Two tone color • Complete front service access • Left/right gas connection • Adjustable fan off times • Cleanable high velocity filters • Optional L.P conversion kit • Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit • Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use) • 5 Year limited parts warranty Pub. No. 22-1682-05-0802 (EN) Features and Benefits OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... TAYSTAT241 [ Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... AY28X092 [ Thermostat, Heating/Cooling Single Stage (Mounts Vertically) .................................................................................... BAYSTAT305 [ Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling .................................................................. TAYSTAT302C [ Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .................................................................. TAYSTAT300C [ Propane Conversion Kit ......................................................................................................................................... BAYLPKT210A [ Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ......................................................... TFE145A9FR0 [ Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ......................................................... TFE175A9FR0 [ Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................... TFE210A9FR0 [ Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ......................................................... TFE245A9FR0 [ Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .......................................................... TFM145A9FR0 [ Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................... TFM175A9FR0 [ Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................................ TFM210A9FR0 [ Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................... TFM245A9FR0 [ Electronic Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..................................................... TFP145A9FR0 [ Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFP175A9FR0 [ Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .......................................................... TFP210A9FR0 [ Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ..................................................... TFP245A9FR0 [ Coil Enclosure (14-1/2" Wide Cabinets) .................................................................................................................. BAYCLE1400C [ Coil Enclosure (17-1/2" Wide Cabinets) .................................................................................................................. BAYCLE1700C [ Coil Enclosure (21" Wide Cabinets) ........................................................................................................................ BAYCLE2100C [ Coil Enclosure (24-1/2" Wide Cabinets) .................................................................................................................. BAYCLE2400C [ Side Filter Rack ........................................................................................................................................................ BAYFLTR200 [ Filter Kit/Horizontal Conversion TUY060, 080-R ......................................................................................................... BAYFLTR203 [ Filter Kit/Horizontal Conversion TUY100-R ................................................................................................................ BAYFLTR204 [ Filter Kit/Horizontal Conversion TUY120-R ................................................................................................................ BAYFLTR205 [ Filter Accessory Kit Upflow 14.5" Furnaces ............................................................................................................... BAYFLTR317 [ Filter Accessory Kit Upflow 21" Furnaces .................................................................................................................. BAYFLTR321 [ Filter Accessory Kit Upflow 24.5" Furnaces ............................................................................................................... BAYFLTR324 [ High Altitude Switch TUY060R .............................................................................................................................. BAYHALT2451 [ High Altitude Switch TUY080, 100R ...................................................................................................................... BAYHALT2461 [ High Altitude Switch TUY120R .............................................................................................................................. BAYHALT2471 [ Concentric Vent Kit ............................................................................................................................................... BAYVENT100A [ Sidewall Vent Termination Kit ................................................................................................................................. BAYVENT200B [ Manufactured/Mobile Home Kit ............................................................................................................................. BAYMFGH100A [ 1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. Pub. No. 22-1682-05-0802 (EN) 5 ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] General Data TUY-R9V PRODUCT SPECIFICATIONS1 MODEL RATINGS2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS)3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS)3 AFUE (ICS) Temp. Rise (Min.-Max.) °F. BLOWER DRIVE Dia.-Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts/Ph/Hz COMBUSTION FAN - TYPE Drive - No. Speeds Motor HP - RPM Volts/Ph/Hz FL Amps FILTER — Furnished? Type Recommended Filter (No.-Size-Thk.) VENT — Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE DIRECT IGNITION DEVICE Type TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V 39000 37000 60000 56000 93.0 35 - 65 52000 49000 80000 73000 92.5 35 - 65 65000 62000 100000 93000 93.0 35 - 65 78000 74000 120000 112000 92.5 40 - 70 DIRECT 10 x 8 1 VARIABLE SEE FAN PERF. TABLE 1/2 VARIABLE 115/1/60 DIRECT 10 x 8 1 VARIABLE SEE FAN PERF. TABLE 1/2 VARIABLE 115/1/60 DIRECT 10 x 10 1 VARIABLE SEE FAN PERF. TABLE 1 VARIABLE 115/1/60 DIRECT 10 x 10 1 VARIABLE SEE FAN PERF. TABLE 1 VARIABLE 115/1/60 CENTRIFUGAL DIRECT - VARIABLE 1/15 - 5000 115/1/60 1.1 CENTRIFUGAL DIRECT - VARIABLE 1/15 - 5000 115/1/60 1.1 CENTRIFUGAL DIRECT - VARIABLE 1/15 - 5000 115/1/60 1.1 CENTRIFUGAL DIRECT - VARIABLE 1/25 - 5000 115/1/60 1.1 YES HIGH VELOCITY 1 X 17 X 25 X 1 YES HIGH VELOCITY 1 X 17 X 25 X 1 YES HIGH VELOCITY 1 - 20 X 25 X 1 YES HIGH VELOCITY 1 - 24 X 25 X 1 2 ROUND 2 ROUND 3 ROUND 3 ROUND ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 20 20 20 20 3 - 45 3 - 56 4 - 45 4 - 56 5 - 45 5 - 56 6 - 45 6 - 56 REDUNDANT - TWO STAGE REDUNDANT - TWO STAGE REDUNDANT - TWO STAGE REDUNDANT - TWO STAGE HOT SURFACE IGNITER HOT SURFACE IGNITER HOT SURFACE IGNITER HOT SURFACE IGNITER BURNERS — Type Number IN-SHOT 3 IN-SHOT 4 IN-SHOT 5 IN-SHOT 6 POWER CONN. — V/Ph/Hz4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) 115/1/60 8.4 15 115/1/60 8.4 15 115/1/60 11.4 15 115/1/60 11.4 15 PIPE CONN. SIZE (IN.) 0.50 0.50 0.50 0.50 DUCT CONN. SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING DIMENSIONS Crated (In.) Uncrated HXWXD 41-3/4 X 19-1/2 X 30-1/2 SEE OUTLINE DRAWING H XW X D 41-3/4 X 19-1/2 X 30-1/2 SEE OUTLINE DRAWING H XW X D 41-3/4 X 23 X 30-1/2 SEE OUTLINE DRAWING HXWXD 41-3/4 X 26-1/2 X 30-1/2 SEE OUTLINE DRAWING 158/146 158/148 171/160 205/193 WEIGHT Shipping (Lbs.)/Net (Lbs.) 1 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub. No. 22-1682-05-0802 (EN) Performance Data *UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRFLOW SETTING LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) 1.5 2.0 2.5 3 DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE SW 4 ON ON OFF ON ON ON OFF OFF ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF ON OFF OFF ON ON OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS 0.1 0.3 0.5 0.7 575 65 640 70 700 85 700 100 800 115 900 140 875 130 1000 175 1125 235 1050 195 1200 275 1325 360 575 90 640 110 700 125 700 130 800 155 900 195 875 180 1000 235 1125 295 1050 260 1200 330 1325 425 575 125 640 140 700 160 700 170 800 200 900 240 875 230 1000 285 1125 345 1050 305 1200 385 1300 460 550 155 630 175 700 200 700 210 800 250 900 290 875 270 1000 335 1100 370 1050 350 1100 385 1175 425 0.9 900 310 925 318 920 315 940 330 1000 365 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. *UY060R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 2nd Stage Capacity = AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 600 57 85 600 57 110 600 57 155 600 57 190 - CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS 700 49 90 775 44 105 870 39 135 860 61 140 1000 53 190 1125 47 250 700 49 130 775 44 155 870 39 185 920 57 200 1000 53 255 1125 47 315 700 49 175 775 44 195 870 39 235 920 57 245 1000 53 305 1125 47 370 700 49 210 775 44 240 870 39 290 920 57 300 1000 53 340 1025 51 355 670 79 245 700 75 255 775 68 285 1250 42 340 1250 42 405 1250 42 445 1100 48 390 1000 53 355 NOTES: * First letter may be "A" or "T" ** Factory setting Pub. No. 22-1682-05-0802 (EN) 37,000 56,000 7 - - - Performance Data TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRFLOW SETTING (See Notes) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) 2.0 NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) 2.5 3.0 DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE SW 4 ON ON OFF ON ON ON OFF OFF ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF ON OFF OFF ON ON OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON 0.1 0.3 0.5 0.7 0.9 CFM WATTS CFM WATTS CFM WATTS CFM WATTS 750 84 840 109 940 136 850 113 750 122 840 146 940 177 850 150 750 154 840 181 940 215 870 200 720 185 840 226 940 274 890 250 710 221 820 264 940 318 890 295 CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS 960 150 1080 195 1020 175 1170 240 1290 310 1170 250 990 200 1110 255 1020 225 1180 300 1320 410 1190 315 1000 230 1120 315 1040 280 1200 365 1350 470 1210 370 1020 305 1120 365 1050 330 1200 415 1340 520 1210 435 1010 350 1080 390 1050 375 1130 420 1150 440 1100 405 1390 445 1390 450 1400 500 1400 520 1360 535 1350 535 1210 475 1180 460 NORMAL CFM 1360 OFF OFF OFF OFF (400 CFM/TON) WATTS 365 HIGH CFM 1360 OFF OFF ON OFF (450 CFM/TON) WATTS 355 NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position. 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 3.5 TUY080R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 2nd Stage Capacity = AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF 49,000 73,000 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS 800 56 105 860 52 115 960 46 150 1080 41 195 800 56 140 880 51 165 990 45 200 1110 40 255 800 56 180 890 50 215 1000 44 230 1120 40 315 800 56 220 920 48 265 1020 44 310 1120 40 365 800 56 265 910 49 320 1010 44 350 1080 41 390 CFM TEMP. RISE WATTS 1100 62 205 1100 62 260 1120 61 320 1120 61 370 1090 63 400 CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS 1210 57 265 1360 50 365 1360 50 355 1240 55 340 1390 49 445 1390 49 450 1260 54 410 1400 49 500 1260 54 470 1360 50 535 1130 61 430 1210 57 475 1400 49 520 1350 51 535 1180 58 465 NOTES: ** Factory setting 8 Pub. No. 22-1682-05-0802 (EN) Performance Data TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRFLOW SETTING (See Notes) 3.0 LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 ON ON OFF ON ON ON OFF OFF ON ON ON OFF CFM WATTS CFM WATTS CFM WATTS 0.1 0.3 0.5 0.7 0.9 1040 165 1210 235 1340 390 1040 220 1210 285 1370 390 1040 270 1230 360 1400 465 1030 320 1230 415 1390 525 1030 375 1230 475 1370 580 1220 280 1430 425 1590 575 1420 415 1640 585 1840 780 1230 365 1430 495 1590 625 1430 490 1640 655 1770 795 1250 425 1430 560 1580 685 1340 550 1590 680 1630 725 1230 485 1400 590 1420 615 1410 595 1420 615 1470 655 LOW CFM 1200 OFF ON OFF ON (350 CFM/TON) WATTS 225 CFM 1390 NORMAL OFF ON OFF OFF 3.5 (400 CFM/TON) WATTS 335 HIGH CFM 1590 OFF ON ON OFF WATTS 490 (450 CFM/TON) CFM 1370 LOW ON OFF OFF ON (350 CFM/TON) WATTS 325 NORMAL CFM 1640 4.0 ON OFF OFF OFF WATTS 515 (400 CFM/TON) CFM 1840 HIGH ON OFF ON OFF (450 CFM/TON) WATTS 700 NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position. 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. TUY100R9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 2nd Stage Capacity = AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS NOTES: ** Factory setting Pub. No. 22-1682-05-0802 (EN) 62,000 93,000 9 0.1 0.3 0.5 0.7 0.9 920 60 130 1020 54 165 1160 48 220 1350 41 320 1290 67 275 1410 61 3561 1640 53 530 1970 44 855 920 60 180 1020 54 220 1160 48 260 1380 40 400 1290 67 355 1460 59 455 1640 53 590 1920 45 895 920 60 220 1020 54 260 1160 48 325 1400 40 470 1330 65 430 1460 59 520 1640 53 660 1780 48 820 920 60 280 1010 55 310 1160 48 390 1400 40 540 1340 64 490 1460 59 590 1600 54 695 1660 52 760 920 60 320 1000 56 365 1150 48 430 1390 40 585 1320 65 545 1370 63 590 1410 61 620 1520 57 695 Performance Data TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 (See Notes) LOW CFM 1210 1210 1220 1230 OFF ON OFF ON (350 CFM/TON) WATTS 220 270 325 400 NORMAL CFM 1400 1440 1450 1450 3.5 OFF ON OFF OFF (400 CFM/TON) WATTS 305 390 465 510 HIGH CFM 1590 1600 1610 1600 OFF ON ON OFF (450 CFM/TON) WATTS 425 520 600 645 LOW CFM 1390 1400 1430 1440 ON OFF OFF ON (350 CFM/TON) WATTS 305 375 445 515 NORMAL CFM 1620 1650 1670 1640 4.0 ON OFF OFF OFF WATTS 420 530 595 660 (400 CFM/TON) HIGH CFM 1840 1830 1820 1670 ON OFF ON OFF (450 CFM/TON) WATTS 600 690 765 700 CFM 1800 1780 1780 1700 LOW OFF OFF OFF ON WATTS 570 630 705 695 (350 CFM/TON) NORMAL CFM 2050 2010 1860 1710 OFF OFF OFF OFF 5 (400 CFM/TON) WATTS 845 875 805 735 CFM 2160 2040 1920 1780 HIGH OFF OFF ON OFF (450 CFM/TON) WATTS 995 935 875 805 NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position. 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 0.9 1230 445 1410 560 1380 575 1420 565 1480 600 1490 620 1530 615 1530 655 1620 730 TUY120R9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 2nd Stage Capacity = AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF 74,000 112,000 CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS 0.1 0.3 0.5 0.7 0.9 1090 62 165 1210 56 220 1340 50 295 1430 47 390 1660 63 485 1870 56 675 2060 51 880 2200 48 1030 1120 60 225 1200 56 280 1360 50 350 1570 43 490 1690 62 590 1870 56 745 1990 53 890 2090 50 965 1080 63 270 1200 56 330 1370 49 425 1580 43 565 1680 62 640 1810 58 770 1850 57 810 1940 54 895 1070 63 310 1180 57 395 1380 49 495 1570 43 625 1640 64 675 1680 62 715 1710 61 750 1790 58 830 1010 67 380 1160 58 455 1330 51 535 1390 49 565 1460 72 600 1490 70 625 1530 68 665 1640 64 750 NOTES: ** Factory setting 10 Pub. No. 22-1682-05-0802 (EN) Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES TUY060,080,100,120R9V-V LEGEND From Dwg. 21D341111 P03 Pub. No. 22-1682-05-0802 (EN) 11 Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341127 Rev. 0 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341126 Rev. 0 12 Pub. No. 22-1682-05-0802 (EN) Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341125 Rev. 1 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341124 Rev. 1 Pub. No. 22-1682-05-0802 (EN) 13 Field Wiring FIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341128 Rev. 0 14 Pub. No. 22-1682-05-0802 (EN) (ALL DIMENSIONS ARE IN INCHES) TUY-R9V-V OUTLINE DRAWING Dimensions Pub. No. 22-1682-05-0802 (EN) 15 Trane A business of American Standard Companies www.trane.com File No. PL-UN-FURN-TDD-D-1 3/98 Supersedes TDD-D-1 8/95 P.I. Since Trane has a policy of continuous product improvement, it reserves the right to change design and specifications without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2003:02:14 14:14:12-06:00 Modify Date : 2003:05:07 15:23:57-07:00 Page Count : 16 Creation Date : 2003:02:14 14:14:12-06:00 Mod Date : 2003:05:07 15:23:57-07:00 Producer : Acrobat Distiller 5.0 (Windows) Author : fegx Metadata Date : 2003:05:07 15:23:57-07:00 Creator : fegx Title : 221682_5.p65EXIF Metadata provided by EXIF.tools