Trane Gas Unit Heaters Catalogue UH PRC002 EN 09/01/2009 Product Catalog Indoor Heating Products Heaters, Duct Furnaces
2015-04-02
: Trane Trane-Gas-Unit-Heaters-Catalogue-684280 trane-gas-unit-heaters-catalogue-684280 trane pdf
Open the PDF directly: View PDF .
Page Count: 69
Download | |
Open PDF In Browser | View PDF |
Product Catalog Indoor Gas Heating Products Unit Heaters Duct Furnaces September 2009 UH-PRC002-EN Introduction Trane unit heaters, offered in both propeller and centrifugal models, are a complete heat generating and distributing plant, equipped with automatic controls, and packaged in an attractive streamlined housing. Designed for ceiling mounting, they provide a convenient low-cost method of comfortably heating stores, factories, warehouses, and other large open areas. Trane unit heaters represent a technological breakthrough in quality. Trane offers customers the most complete line of unit heaters anywhere. And every unit in the line has been rated for 80 percent thermal efficiency or better. But higher thermal efficiency and lower operating costs are just two features of this product line. Innovation—the engineering advances you’ve come to expect from Trane—can also be found across this entire line of unit heaters. And rugged, quality construction provides years of dependable service. Quality products mean Trane value. So does fair, competitive pricing. The 10-year warranty tells you Trane will be here for the long haul—keeping our commitment to you. You can count on Trane standing behind every unit shipped. That is what Trane value means. Trademarks Trane and the Trane logo are trademarks of Trane in the United States and other countries. © 2009 Trane All rights reserved UH-PRC002-EN Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Features Highlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Venting Unit Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Indoor Gas Heating Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Model Number Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Horizontal Blower Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Service Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Heat Throw Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Gas Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Sequence of Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Single-Stage Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Two-Stage Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic Modulating Control (with duct thermostat) . . . . . . . . . . . . . . . Electronic Modulating Control (with room thermostat) . . . . . . . . . . . . . . High-Efficiency Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Separated Combustion Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 34 35 37 39 43 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Dimensions and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Tubular Heat Exchanger Indoor Gas Unit (model GT) . . . . . . . . . . . . . . . 58 High Efficiency Propeller (model GH) and Centrifugal Fan Gas Unit Heaters (model GB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Separated Combustion Centrifugal (model GK) and Propeller Fan Gas Unit Heaters (model GA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 High Efficiency Indoor Gas Duct Furnaces (model GL) . . . . . . . . . . . . . . 63 Separated Combustion Duct Furnaces (model GM) . . . . . . . . . . . . . . . . . 65 Horizontal Blower Assembly (model HBAC) . . . . . . . . . . . . . . . . . . . . . . . 67 UH-PRC002-EN 3 Features Highlights Ten-Year Warranty The complete heat exchanger, draft hood assembly of the unit heater and burners are warranted by Trane to be free from defects in material and workmanship for a period of 10 years from the date of manufacture. (Warranty not applicable on duct furnaces or Separated Combustion units.) Quiet Operation Trane unit heaters incorporate an exceptionally balanced fan blade to assure quiet operation. Heat Exchangers All Trane heat exchangers are available in three types of steel: • Aluminized Steel (Standard) • 409 Grade Stainless Steel (Optional) (30–400 MBh units) • 321 Grade Stainless Steel (Optional) (100–400 MBh units) 24V System All units are equipped with a 24Vcontrol system which is powered by a 24V transformer as standard equipment. Fan Time Delay The fan time delay switch is mounted at the factory as standard equipment on all unit heaters (optional on duct furnaces). This feature eliminates an initial blast of cold air by allowing the unit to fire for a short period of time before actuating the fan motor. After the thermostat is satisfied (with burners off), the fan continues to operate for approximately one minute, removing residual heat from heat exchanger. Burners All sizes 30,000 through 400,000 Btu input are equipped with a proven design pressed steel burner having a unique “burner shade” protective device to prevent scale or foreign matter from plugging the burner ports. Energy Saving Ignition Pilot Control The pilot burner is ignited only during each cycle of operation, thereby conserving energy during the off cycle. LP/Natural Operation All units are available for operation on either natural or LP gas from our factory. Easy Access For Maintenance All Trane unit heaters are so designed that the burner access panel is removed with just two screws. Burners are individually removable for inspection and servicing. Pilot is also accessible through side panel access door. Test Fire All Trane unit heaters are test fired to assure proper operation. Ideal For Retrofit Trane unit heaters let you pocket fuel savings from day one and provide years of dependable service. 4 UH-PRC002-EN Features and Benefits Propeller Fan / Tubular Heat Exchanger Unit Heaters Trane has added a new unit heater to enhance its broad line of heating products. The Trane tubular heat exchanger is a very durable unit heater that provides an alternative to the traditional clam shell style. These are propeller style units that combine the latest tubular heat exchanger style with inshot burner technology to create a very efficient operating unit. High Efficiency Propeller Fan Unit Heaters Trane high-efficiency propeller fan unit heaters achieve annual fuel savings of 20 to 25 percent over conventional gravity vented heaters. Each unit features a factory-installed power venter fan and sealed flue collector that controls combustion and excess air during the on-cycle. Heated air no longer escapes through the draft diverter opening during the off-cycle. Energy saving spark ignition reduces gas losses. The pilot only operates when required. Horizontal power venting allows side wall venting, smaller openings, and single-walled vent pipe, reducing heat loss. Higher efficiencies can reduce equipment and material costs as well as installation time. High Efficiency Centrifugal Fan Unit Heaters The high-efficiency centrifugal fan unit heater keeps energy costs down. The design advances achieve annual fuel savings of 20 to 25 percent over conventional gravity vented heaters. The high-efficiency centrifugal unit features integral power venting (factory-installed) and sealed flue collector for optimum combustion. Electronic spark ignition reduces pilot gas losses, and the power venter allows for horizontal venting through side walls. It adds up to higher seasonal efficiencies and lower installation time. High Efficiency Indoor Duct Furnace The high efficiency indoor gas duct furnace complements our current centrifugal and propeller fan lines. All high efficiency lines were designed to achieve fuel savings of up to 25 percent over conventional gravity vented heaters. Conventional gravity vented heaters lost heated room air through the draft diverter opening. The high efficiency line features an integral flue vent fan and sealed flue collector for improved combustion. It reduces air requirements and wind effects on the system’s efficiency. Intermittent pilot ignition reduces pilot gas losses and the flue vent fan allows for horizontal venting through side walls. Note: DUCT FURNACES ARE APPROVED FOR BLOW-THROUGH APPLICATIONS ONLY. Horizontal Blower Assemblies Trane horizontal blower assemblies have been specially designed for air handling systems of high static pressure in combination with Trane duct furnaces. They are matched against the proper furnace size for greatest efficiency of operation. UH-PRC002-EN 5 Features and Benefits Separated Combustion Propeller Fan Unit Heaters The Trane separated combustion propeller type unit heater keeps energy costs down by offering 80 percent thermal efficiencies. With model inputs available from 100 through 400 MBH, they are designed to be installed in mildly hostile environments where dusty, dirty and mildly corrosives exist or high humidity or slightly negative pressures prevail. The Trane propeller unit separates the combustion process from the environment where the unit is installed. A power venting system draws a controlled quantity of combustion air from outside the building. The same system exhausts flue gas products to the outside. The burners, pilot and flue system are enclosed within the unit. The entire combustion process is literally unaffected by the atmosphere in the space where the unit is located. Combustion and exhaust air may be piped horizontally through a side wall, or vertically through the roof via our standard two-pipe venting arrangement or optional concentric vent kit which utilizes one 8-inch side wall or rooftop penetration for both the combustion and exhaust air. Both venting systems are C.S.A. International certified. Separated Combustion Centrifugal Fan Unit Heaters The Trane separated combustion centrifugal type unit heater keeps energy costs down by offering 80 percent thermal efficiencies. With model inputs available from 100 through 400 MBh, they are designed to be installed in mildly hostile environments where dusty, dirty and mildly corrosives exist or high humidity or slightly negative pressures prevail. This unit operates at a static pressure up to 0.2” water column, and is available with a louvered (standard) or flanged outlet (optional) when discharge duct work is desired. These units separate the combustion process from the environment where the unit is installed. A power venting system draws a controlled quantity of combustion air from outside the building. The same system exhausts flue gas products to the outside. The burners, pilot and flue system are enclosed within the unit. The entire combustion process is literally unaffected by the atmosphere in the space where the unit is located. Separated Combustion Duct Furnace The Trane separated combustion duct furnace is designed for installation in dusty, dirty or mildly corrosive environments or where high humidity or slightly negative pressures exist. Ideal applications include HVAC equipment rooms, manufacturing facilities, automotive garages and greenhouses. 6 UH-PRC002-EN Application Considerations General Propeller fan unit heaters and centrifugal fan unit heaters are designed for use in space heating applications. The units are typically used in areas with high ceilings, and are exposed in the space to be heated. Unit heaters offer low installed cost, and are able to heat large volume areas without requiring extensive duct systems. Duct furnaces are designed for use in ducted applications with a separate air handling device such as a horizontal blower assembly. By utilizing a separate air source, greater application flexibility in airflow delivery can be obtained. Multiple duct furnaces can be used with an air handling unit to provide zone heating. Note: When installing duct furnaces in parallel or in series, minimum clearance requirements must be considered. This is required for serviceability of the gas valve and the high limit. “All duct furnaces are approved in blow-thru applications only.” All duct furnaces are AGA approved upstream or downstream of the cooling coil. Recommend optional field installed drain pan when installed on the downstream side of the cooling coil. Note: Downstream denotes cooling coil ahead of the fan section. When used in conjunction with filters, cooling coils and an air handler, the duct furnace can become part of a built-up heating and cooling system. Gas Heating Value The majority of gas heating units are installed in applications where natural gas is readily available. In areas where natural gas is not available, Trane units may be ordered directly from the factory for use on LP (propane) gas. Gas heat content varies by fuel type and location. The standard gross heating value for natural gas is 1,000 Btu per cubic foot, and for propane, 2,500 Btu per cubic foot. Significant variations from these standard values should be taken into consideration in equipment selections. To account for variations in the gross heating value of the fuel, adjust the total heat input required and select the unit on the basis of the adjusted load using the following formula: Adjusted load = Calculated load x gross heat value (Btu/ft3) Actual gross heat value (Btu/ft3) Low Temperature Rise Trane recommends against the setup of a unit which will result in a temperature rise of less than 30°F. With such low temperature rises, the flue gases passing through the heat exchanger are cooled to condensate before reaching the flue outlet. This condensate is corrosive and will result in shortened heat exchanger life. Air Density Catalog performance data is based on elevations up to 2,000 feet above sea level. Above 2,000 feet the unit’s heating capacity must be derated four percent for each 1,000 feet above sea level, and UH-PRC002-EN 7 Application Considerations special orifice selections are required. Table 8, p. 24 contains correction factors that can be applied to the unit’s cataloged heating capacity, fan rpm, and fan bhp to obtain actual values for elevations above 2,000 feet. Corrosive Atmospheres Corrosion of heat exchangers and draft diverters have two basic variables—moisture (condensation) and sulphur. These two ingredients form to make sulfuric acid in the combustion process. Condensation occurs commonly in makeup air systems, using large amounts of fresh air, when air temperatures entering the heat exchanger drop to 40°F or below. This reaction can also occur in recirculating systems where some quantity of outside air is introduced upstream of the exchanger. The sulphur will always be present as an integral component of the gas. The resulting concentration of the acid is governed by the amount of sulphur in the gas. This concentration varies from gas to gas and geographically within the same type of gas. Beyond sulfuric acid corrosion there is the area of chlorinated or halogenated hydrocarbon vapor corrosion. This type of corrosion occurs when substances are mixed with combustion air that will cause the formation of hydrochloric or hydrofluoric acid when burned. These basic substances are found in degreasers, dry cleaning solvents, glues, cements, paint removers and aerosol propellants. Specific chemicals included in this group are trichloroethylene, perchloroethylene, carbon tetrachloride, methylene chloride, methyl chloroform and refrigerants 11, 12, 21, 22 and 114. If sufficient PPM content of these corrosives is present, none of the common heat exchanger materials will hold up. The dilemma becomes whether to place the gas heating equipment outside of the area to be conditioned, or use equipment in the space which does not burn a fuel such as gas (i.e., electric or hydronic). Units should not be installed in areas with corrosive or inflammable atmospheres. Locations containing solvents or chlorinated hydrocarbons will produce corrosive acids when coming in contact with burner flames. This reaction will greatly reduce the life of the heat exchanger and may void the warranty. For added protection against heat exchanger corrosion, optional 409 and 321 stainless steel construction is available. On units using outside air, with entering air temperature below 40°F, condensation of flue gas in the heat exchanger is possible. In these cases, stainless steel heat exchangers are recommended. Careful review of the job application with respect to use, probable contaminants within a conditioned space or the amount of fresh air to be brought in, will help to make the proper selection of heat exchanger material. This review will help to eliminate problems before they begin. Indoor Units Indoor gas unit heaters and duct furnaces are used primarily in commercial and industrial structures such as manufacturing areas, warehouses, garages, stores, showrooms, lobbies, and corridors. Separated combustion units are used primarily in industrial work areas with wood or textile dust, non-explosive contaminated environments, nonchlorine process areas, automotive and truck garages and greenhouses. Unit Placement Refer to the applicable Trane Installation, Operation and Maintenance literature for specific installation instructions. Installations must conform with local building codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223.1. When selecting a location for an indoor unit heater, both the size and weight of the unit, as well as the heating requirements of the building, should be considered. Installation of units in airplane hangars or public garages should be in accordance with NFPA No. 409 for aircraft hangars, and NFPA No. 88 for garages. For proper distribution, air should be directed towards areas of maximum heat loss. When multiple units are used, circulation of heated air around the space perimeter is recommended. Satisfactory results can also be obtained where multiple units are located toward the center of the area, with 8 UH-PRC002-EN Application Considerations heated air being discharged toward the outside walls. Throw data for standard unit heaters and unit heaters utilizing optional discharge nozzles is shown in “General Data,” p. 20. Locations where extreme drafts can affect burner operation should be avoided. Strong drafts may cause pilot outage. Units with intermittent pilot ignition may be preferable in areas where drafts are likely. Minimum clearances required for accessibility and safety are listed in Table 2, p. 20. Mounting Detail (Hanging Hardware Supplied by Others) Figure 1. Steel Construction Figure 2. Wood Construction Throw Data Throw data for units with standard louvers and for units with optional discharge nozzles are in “General Data,” p. 20. Optional nozzles are for use on propeller fan unit heaters, centrifugal fan unit heaters and duct furnaces. When greater throw distance is desired, a 45° nozzle is recommended. For high mounting heights, a 90° nozzle may be used. When wide diffusion is needed, a Y splitter nozzle should be considered. A five-way nozzle can be used for applications requiring even air UH-PRC002-EN 9 Application Considerations distribution over a large floor area. (Five-way nozzles are not available on propeller fan unit heaters.) Indoor Units—Venting Gas fired indoor units require venting to remove the products of combustion. To help assure safe, trouble-free operation, follow the guidelines listed below: Power Vented Units Units with a factory installed flue vent fan. 1. All units must be vented. Power vented units are designed to use single wallvent pipe. A Breidert Type L, Field Starkap, or equivalent unit vent cap must be furnished by the customer. 2. The venting system for these appliances shall terminate at least 4 feet below, 4 feet horizontally from, or 1 foot above any door, window or gravity air inlet into any building. 3. Through-the-wall vents for these appliances shall not terminate over public walkways or over an area where condensate or vapor could create a nuisance or hazard or could be detrimental to the operation of regulators, relief valves, or other equipment. 4. The vent pipe diameter must be as shown under “Recommended Flue Size” in the specification charts. An adaptor must be field supplied if required. 5. Each furnace must have an individual vent pipe and vent terminal. Vent pipe equivalent length must not exceed 50 feet. Equivalent length is the total length of straight sections, plus 15 feet for each 90° elbow and 8 feet for each 45° elbow. 6. Maintain 6 inch clearance between vent pipe and combustible materials. Vent terminal must be installed with a minimum clearance of 4 feet from electric meters, gas meters, regulators, and relief equipment. 7. Seal vent pipe joints to prevent leakage. Use General Electric RTV-108 or Dow Corning RTV-732 Silicone Sealant or 3M #425 aluminum foil tape. 8. Pitch horizontal pipes downward 1/4-inch per foot toward outlet for condensate drainage. Horizontal portions of the venting system shall be supported at maximum intervals of 4 feet to prevent sagging. 9. Vertical vent pipes should be equipped with condensate drains. 10. Insulate single wall vent pipe exposed to cold air or running through unheated areas. FM and IRI Requirements IRI, which stands for Industrial Risk Insurers, and FM, which stands for Factory Mutual, are both basically insurance companies which insure commercial/industrial firms against a variety of losses. Both publish requirements which must be met by certain equipment operating in the facilities they are preparing to insure. Listed below is our interpretation of the requirements of both insurers pertaining to heating units only to the extent of features/controls required by IRI and/or FM. There are a number of additional requirements which pertain to electrical service, details of installation, etc., and we urge you to obtain copies of the publications pertaining to these details if you are involved in a job where IRI or FM adherence has been indicated. The requirements detailed herein are our interpretations of the latest publications in our possession and we must disclaim any responsibility for errors due to our interpretation and/or lack of any updated revision of these standards. Our intent is to provide you with an understanding of the application of these standards and how we believe our indirectfired gas heating equipment applies. IRI Requirements 1. All input sizes require 100 percent shutoff. This requires that any natural gas unit, equipped with intermittent pilot ignition, must employ a “lock out” type ignition system which will shut off pilot gas if the pilot fails to light at any time. This system is required by AGA on LP gas units 10 UH-PRC002-EN Application Considerations as standard equipment. However, for natural gas units, you need to specify on the order “Natural Gas, 100 percent shutoff.” 2. All units require AGA certification or UL “listed” controls. Our units are AGA certified and meet this requirement. 3. Models with inputs of 150,000 to 400,000 Btu require “mechanical exhaust” and a “safety interlock.” For our units, this means a power vented or drafter-equipped unit. In both instances, if the flue vent fan (factory or field installed) does not get up to speed, the unit will not fire, satisfying the safety interlock portion. FM Requirements 1. All units must be AGA certified or UL listed. Our units are AGA certified. 2. The high limit control must be in a circuit, the voltage of which does not exceed 120 Vac. All of our high limits would meet this requirement. The specific requirement for an “IRI or FM Gas Train,” while it applies to direct and indirect-fired gas heating equipment as well as oil-fired, comes into play only with units having an input in excess of 400,000 Btu. This may be one of the reasons why the majority of gas heating equipment manufacturers (indirect-fired) limit their largest individual furnace to 400,000 Btu. Minimum/Maximum Gas Inlet Pressures Gas valves are suitable to a maximum inlet pressure of 0.5 psi (14 inches water column) on natural gas. If the main gas supply pressure is greater than 14 inches wc, a step-down pressure regulator must be field-installed ahead of the gas valve. Minimum inlet pressure for natural gas units is 5 inches wc. For LP (propane) gas, the minimum inlet pressure is 11.0 inches wc and the maximum inlet pressure is 14.0 inches wc. High Pressure Regulators—Natural Gas Only The Trane indoor gas heating products contained in this catalog are designed to operate at a pressure of 3.5-inch wc (water column) when firing on natural gas. This is the “manifold” pressure or that which is present at the burner orifices. All five- and six-function valves provide a built-in pressure regulator which is capable of reducing “supply” pressures from a maximum of 14-inch wc (1/2 psi) down to 3.5-inch wc on the leaving side of the valve. The valve typically “drops” about 1-1/2 inches so the minimum supply pressure is 5-inch wc. Whenever supply pressures exceed 14 inches wc, a high pressure regulator should be selected. We supply a Rockwell regulator which is fitted with pressure springs and capacity orificing to meet the requirements of each specific job. In order to select the proper spring/orifice combination, we need to know what the supply pressure is on that particular job and the input size of the unit being ordered. More than one unit can be run from one regulator; however, we recommend that each unit have its own regulator. We require that the “job” supply pressure be included on all jobs requiring high pressure regulators along with the unit size. Table 1 displays the regulators range as it pertains to inlet pressure and MBh. A dash (—) requires the customer to contact a local utility or an industrial supply house. These devices are not available from Trane for LP gas. LP accessories must be secured from the gas supplier/ supply house. UH-PRC002-EN 11 Application Considerations Table 1. Orifice chart: Rockwell 043–182 regulator Inlet Pressure (psi) 1 2 3 5 10 20 40 60 80 100 125 25–200 3/8” 3/8” 3/8” 3/8” 3/8” 1/4” 1/4” 1/8” 1/8” 1/8” 1/8” Capacity in Mbh for Natural Gas 225–300 350–500 600 700 — — — — 3/8” — — — 3/8” 3/8” — — 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 800 — — — 3/8” 3/8” 5/16” 1/4” 3/16” — 1/8” 1/8” Spring Required Blue (only) Blue (only) Blue or Green Blue or Green Blue or Green Blue or Green Blue or Green Blue or Green Blue or Green Blue or Green Blue or Green Venting Unit Heaters Venting unit heaters and duct furnaces used to be as simple as remembering that warm air rises. With the introduction of new venting equipment and safety controls, things have become a little more technical. Today’s contractor has to know a lot more about proper venting to get the job done within code at a reasonable price. For starters, ANSI now categorizes vented appliances into four categories. Category I includes noncondensing appliances with negative vent pressure, like the traditional atmospheric unit heater. Category II groups condensing appliances with negative vent pressure. Category III appliances are non-condensing and operate with a positive vent pressure, like the traditional power vented unit heater. Category IV covers condensing appliances with positive vent pressure. Venting Categories Negative Vent Pressure Positive Vent Pressure Non-Condensing Condensing I III II IV Sharing Flues with Other Appliances Never connect power vented devices to common flues. Mechanically vented appliances must have dedicated vents to the point of termination. Power Vented Unit Heaters Mechanically vented appliances have enjoyed increasing acceptance in American facilities. Power vented unit heaters allow installation without the need to penetrate expensive roofing materials. They also offer more flexibility in placement of individual unit heaters. 12 UH-PRC002-EN Application Considerations Figure 3. Power vented unit heater Mechanical venting occurs when a power blower provides a positive air flow to exhaust vent gas. The blower may be mounted at the unit heater or at the point of termination. With a factoryinstalled power venter, a pressure switch detects the flow of vent gas before the gas valve is allowed to open. With third party drafters, a centrifugal switch usually monitors the operation of the blower motor. When properly installed, the switch senses motor rotation and allows the gas valve to operate. Interlocking the blower to the gas valve provides some control over the combustion process. Using a factory unit with a pressure sensitive switch ensures that control. With all their advantages, power venters bring some requirements as well. Each manufacturer determines the maximum length of pipe and fittings that his system can use for safe operation. Remember to count the fittings and allow for their higher resistance to flow. The total length of run includes not only the piping length, but the resistance of all the fittings including the termination cap. Many contractors have become accustomed to using B vent with natural draft units. Used with power vented appliances indoors, B vent is unacceptable. B vent does not allow positive pressure in the vent piping to be sealed from the heated space. Proper installation uses 24-gauge, single wall vent pipe and each joint sealed with temperature resistant sealant or tape. Contractors must also be aware of the conditions at the point of termination. The National Fuel Gas Code NFPA 54/ANSI Z223.1-1992 mandates that vent system should terminate at least 4 feet below, 4 feet horizontally or 1 foot above any window, door, or gravity inlet to a building. Termination with a vent cap approved by the manufacturer should occur well above the snow line. Figure 4. Vent termination locations (minimum distance) UH-PRC002-EN 13 Application Considerations Beyond satisfying the codes, vents should be positioned away from shrubs and plants that might be affected by unseasonable warming by the exhaust. Sidewall vents release a considerable amount of water vapor that may condense on cold siding, adversely affecting painted surfaces. Placing these vents in locations that get natural air circulation from prevailing winds may help to reduce these negative effects. 1 2 1. Heat 2. Fumes 3. Humidity 3 Separated Combustion Venting Another form of mechanical venting includes those unit heaters that use a powered exhaust also to pull in outside air. Most often found on condensing furnaces, separated combustion does not use room air for combustion. Instead these unit heaters use a second run of pipe to supply fresh outdoor air. The separated combustion approach offers several advantages. First, it does not use warm indoor air to fire the unit heater. This saves energy by avoiding drawing unheated make-up air into the living space. Second, the unit heater has an unlimited source of air for combustion. In many of the new super insulated buildings appliances can be starved for combustion air. In contaminated atmospheres the use of separated combustion unit heaters assures that the heat exchanger sees only non-corrosive air. When positioning the intake and exhaust vents on separated combustion equipment, the intake and outlet must mount on the same outside surface. This ensures that any wind effects balance out. Remember to keep the vents at least 18” apart to avoid drawing exhaust air into the intake air. With Trane’s separated combustion unit heaters intake air and exhaust air run through standard 24-gauge galvanized pipe. Remember that separated combustion unit heaters still have high vent 14 UH-PRC002-EN Application Considerations temperatures. Use of PVC, CPVC and other plastic vent materials are inappropriate and hazardous. Check the manufacturer’s instructions before piping any appliance. The vent gases of power vented and separated combustion unit heaters may condense on a cold start-up or when vent piping runs through unheated areas. To protect the heater always pitch both intake and exhaust piping toward the outside of the building. Remember also that no power vented equipment can share a common flue with any other appliance. Should a flue become blocked one appliance could vent into the occupied space. Approved vent caps should be used on both the intake and exhaust terminations. For greater convenience Trane offers a concentric vent adapter that allows venting through a single perforation through the building wall or roof. UH-PRC002-EN 15 Selection Procedure Determine the total heating load requirements in accordance with methods recommended by the ASHRAE Handbook of Fundamentals or other acceptable means. High Efficiency Propeller Fan Unit Heater 1. From the performance data tables, select the unit whose heating output meets or exceeds the heating load requirement. 2. Airflow (cfm) and temperature rise can be read directly from the performance data tables. 3. Knowing the mounting height of the unit, throw can be determined from the performance data table. If the throw is not adequate, consider using a larger propeller fan unit heater or a centrifugal fan unit heater with an optional discharge nozzle for greater throw. Selection Example—A natural gas propeller fan unit heater that can provide 75 MBh heating output is required. The unit will be mounted 10 feet above the floor and a 40-foot throw is required. Select the unit as follows: a. From Table 10, p. 25, select a GHND-010 with 100.0 MBh input and 80.0 MBh heating output, 1,480 cfm and a 50°F temperature rise. b. From Table 3, p. 20, throw at a mounting height of 10 feet is 54 feet. High Efficiency Centrifugal Fan Unit Heater 1. From the performance data tables, select the unit whose heating output meets or exceeds the heating load requirement. 2. Airflow (cfm) ranges are listed for each unit size in the performance data tables. Knowing either the desired airflow or temperature rise, the other can be calculated using the following formulas: cfm = Output x 1,000 1.085 x ΔT ΔT = Output x 1,000 1.085 x cfm 3. Knowing the mounting height of the unit, throw can be determined from the performance data table. If the throw is not adequate, a discharge nozzle can be used to obtain additional throw. Selection Example—An LP (Propane) gas centrifugal fan unit heater that can provide 150 MBh heating output is required. An airflow of 2,000 cfm is desired. The unit will be mounted 12 feet above the floor and a 65-foot throw is required. Select the unit as follows: a. From Table 11, p. 25, select a GBPD-020 with a 200.0 MBh input and 160.0 MBh heating output. An airflow of 2,000 cfm is within the allowable range, and temperature rise is calculated as follows: ΔT = MBh x 1,000 1.085 x χφμ ΔT = 160 x 1,000 1.085 x 2,000 = 74.0°F b. From Table 3, p. 20, throw at a 12-foot mounting height is 61 feet. As a 61-foot throw is not adequate, a 60-degree nozzle can be selected (from Table 5, p. 21) which provides a throw of 76 feet. 16 UH-PRC002-EN Selection Procedure High Efficiency Duct Furnace 1. From the performance data tables, select the unit whose heating output meets or exceeds the heating load requirement. 2. Given the airflow to be supplied to the duct furnace, temperature rise and pressure drop through the duct furnace can be read directly from the performance data charts. If the air temperature rise is below 30°F, some supply air must be bypassed around the duct furnace. If the air temperature rise is over 80°F, additional supply air must be delivered to the duct furnace. Selection Example—A natural gas duct furnace that can provide 300 MBh heating output is required. An airflow of 5,000 cfm is being provided to the duct furnace. Select the unit as follows: a. From Table 14, p. 27, select a GLND-040 with a 400.0 MBh input and 320.0 MBh heating output. b. From Figure 10, p. 29, temperature rise at 5,000 cfm is 58°F and pressure drop is 0.16 inches. Horizontal Blower Assembly 1. From the performance data tables, select the blower assembly that provides the needed airflow at the required static pressure, and determine the required motor size and fan speed. 2. If a blower assembly is to be used with a duct furnace, refer to the dimensional data table to determine which blower to use with the given duct furnace. The duct furnace pressure drop must be added to the pressure drop of the duct system before entering the blower assembly performance data tables. Enter the performance data table at the required airflow and at the total external static pressure to determine the motor size and fan speed. Selection Example—A GLND-040 high efficiency duct furnace is to be used with a horizontal blower assembly. An airflow of 5,000 cfm is required. The pressure drop of the duct system is 0.54 inches, and the pressure drop of the duct furnace is 0.16 inches. Select the unit as follows: a. From Table 29, p. 55, select a HBAC-45 for use with the GLND-040 duct furnace. b. From Table 16, p. 28, an HBAC-45 at 5,000 cfm and 0.7 inches static pressure (0.54-inch ductwork + 0.16-inch furnace) requires a 1-1/2 hp motor with a fan speed of 720 rpm. UH-PRC002-EN 17 Model Number Descriptions Indoor Gas Heating Units Note: All units are AGA approved. For CGA approved units, contact Air Handling Product Support. Digit 1 — Gas Heating Equipment Digit 9 — Gas Control Option D = E = H = J = L = N = T V = = Digit 2 — Product Type B = L = H = A = K = High Efficiency Centrifugal Fan Unit Heater High Efficiency Indoor Duct Furnace High Efficiency Propeller Fan Unit Heater Separated Combustion Propeller Fan Unit Heater Separated Combustion Centrifugal Fan Unit Heater Separated Combustion Indoor Duct Furnace Propeller Fan / Tubular Heat Exchanger M = T = Single-Stage, Intermittent Pilot Ignition Two-Stage, Intermittent Pilot Ignition Electronic Modulating with Room T-Stat, Intermittent Pilot Ignition Electronic Modulating with Duct-Stat, Intermittent Pilot Ignition Electronic Modulating with External 4–20 mA Input Electronic Modulating with External 0–10 Vdc Input Single Stage Direct Spark Ignition Two-Stage, Direct Spark Ignition Digit 10 — Design Sequence G = Seventh Design Digit 11 — Heat Exchanger Material Digit 3 — Fuel 1 2 3 N P Digit 12 — Rooftop Arrangements = = Natural Gas LP Gas (Propane) Digit 4 — Development Sequence D = 0 = = = = Aluminized Steel #409 Stainless Steel #321 Stainless Steel None (Indoor Unit) Digit 13 — Rooftop Heating Unit Motor Selection Fourth Generation Digits 5, 6, 7 — Input Capacity 0 = Single Furnace None (Indoor Unit and Rooftop Duct Furnace) 003(a) = 30 MBh 015 = 150 MBh Digit 14 — Rooftop Fan Section 004(a) = 45 MBh 017 = 175 MBh 0 006(a) = 60 MBh 020 = 200 MBh 007(a) = 75 MBh 022 = 225 MBh 009 90 MBh 025 = 250 MBh 010(b) = = 100 MBh 030 = 300 MBh 011(c) = 105 MBh 035 = 350 MBh 120(c) = 120 MBh 040 = 400 MBh 012(b) = 125 MBh = None (Indoor Unit and Rooftop Duct Furnace) Digit 15 — Miscellaneous Options All 0 A B Units = None = #409 Stainless Steel Burners1 = Orifices For Elevation Above 2000 Feet (Specify Elevation) Propeller Fan Unit Heater (High Efficiency and Separated Combustion) C = #409 Stainless Steel Draft Diverter D = Summer-Winter Switch E = Vertical Louvers J = Totally Enclosed Motor 7 = OSHA Fan Guard Centrifugal Fan Unit Heater (High Efficiency and Separated Combustion) C = #409 Stainless Steel Draft Diverter D = Summer-Winter Switch E = Vertical Louvers H = Duct Discharge Flange J = Totally Enclosed Motor Duct Furnace (Indoor) (High Efficiency) C = #409 Stainless Steel Draft Diverter D = Summer-Winter Switch F = Horizontal Louvers G = Horizontal and Vertical Louvers K = Side Access Burner Drawer (Left Hand)2 L = Fan Time Delay Control M = Side Access Burner Drawer (Right Hand)2 Separated Combustion, Indoor Duct Furnace C = #409 Stainless Steel Draft Diverter D = Summer-Winter Switch F = Horizontal Louvers G = Horizontal and Vertical Louvers Propeller Type / Tubular Heat Exchanger J = Totally Enclosed Motor 7 = OSHA Fan Guard (a) Not available for high efficiency propeller fan. (b) Not available for tubular. (c) Available for tubular only. Digit 8 — Main Power Supply A = 115/60/1 D = 230/60/3 B = 230/60/1 E = 460/60/3 C = 208/60/3 F = 575/60/3 1 2 18 Not available for tubular. The left or right hand side of the side access burner drawer, options K & M, is determined by facing the air outlet side of the duct furnace. UH-PRC002-EN Model Number Descriptions Horizontal Blower Assembly Digit 1, 2, 3 — Horizontal Blower Assembly Digit 4 — Development Sequence C = Third Generation Digit 5, 6 — Blower Size 15 20 30 45 = = = = Nominal 1500 cfm Nominal 2000 cfm Nominal 3000 cfm Nominal 4500 cfm Digit 7 — Transition Size (Specifies Duct Furnace Size) 0 = None A = 100 MBh F = 225 MBh B = 125 MBh G = 250 MBh C = 150 MBh H = 300 MBh D = 175 MBh J = 350 MBh E = 200 MBh K = 400 MBh Digit 8 — Main Power Supply A = 115/60/1 D = 230/60/3 B = 230/60/1 E = 460/60/3 C = 208/60/3 Digit 9 — Motor Horsepower A = 1/3 hp D = B = 1/2 hp E = 1 hp 1-1/2 hp C = 3/4 hp F = 2 hp Digit 10 — Design Sequence D = Fourth Design Digit 11 — Miscellaneous Options 0 1 3 = = = None Insulation Totally Enclosed Motor UH-PRC002-EN 19 General Data Service Clearances Table 2. Minimum clearances Duct Furnace 18” 6” 21”(a) 6” Sides Top Bottom Flue Propeller & Centrifugal Fan U.H. 18” 6” 21” 6” (a) 21” clearance is required for bottom access to burners and pilot. If a side pull-out burner drawer is ordered (duct furnace only), bottom clearance can be reduced to six inches. Side clearance, however, must be increased such that it is adequate for burner drawer removal. Reference Table 27, p. 53. Heat Throw Data Figure 5. Standard unit heater applications Table 3. Standard unit heater—approximate distance of throw at nominal airflow Distance From Floor to Bottom of Unit “H” ft (m) 8 (2.4) 10 (3.0) 12 (3.7) 15 (4.6) 20 (6.1) 20 30 (8.8) 33 (10.1) 28 (8.5) — 45 (13.2) 33 (10.1) 28 (8.5) — 60 (17.6) 33 (10.1) 28 (8.5) — 75 (22.0) 40 (12.2) 35 (10.7) — — 100 (29.3) 60 (18.3) 54 (16.5) 44 (13.4) — 125 (36.6) 65 (19.8) 56 (17.1) 46 (14.0) — — — — — — — — — — Unit Size Input MBh (kW) 150 175 (43.9) (51.2) 70 75 (21.3) (22.9) 60 64 (18.3) (19.5) 49 57 (14.9) (17.4) 45 49 (13.7) (14.9) — — 200 (58.6) 80 (24.4) 68 (20.7) 61 (18.6) 52 (15.8) 46 (14.0) 225 (65.9) 85 (25.9) 72 (21.9) 65 (19.8) 56 (17.1) 50 (15.2) 250 (73.2) 90 (27.4) 78 (23.8) 68 (20.7) 60 (18.3) 54 (16.5) 300 (87.8) 105 (32.0) 90 (27.4) 80 (24.4) 70 (21.3) 63 (19.2) 350 400 (102.5) (117.1) 110 120 (33.5) (36.6) 95 100 (29.0) (30.5) 84 90 (25.6) (27.4) 74 80 (22.6) (24.4) 66 70 (20.1) (21.3) UH-PRC002-EN General Data Figure 6. 30° nozzle Table 4. 30-degree nozzle—approximate distance of throw at nominal airflow Distance From Floor to Bottom of Unit “H” ft (m) 8 (2.4) 10 (3.0) 12 (3.7) 15 (4.6) 20 (6.1) 100 (29.3) 65 (19.8) 57 (17.4) 50 (15.2) — — 125 (36.6) 70 (21.3) 60 (18.3) 54 (16.5) 45 (13.7) — 150 (43.9) 75 (22.9) 64 (19.5) 57 (17.4) 48 (14.6) — 175 (51.2) 80 (24.4) 68 (20.7) 60 (18.3) 50 (15.2) 44 (13.4) Unit Size Input MBh (kW) 200 225 (58.6) (65.9) 85 90 (25.9) (27.4) 72 78 (21.9) (23.8) 64 70 (19.5) (21.3) 53 59 (16.2) (18.0) 47 53 (14.3) (16.2) 250 (73.2) 95 (29.0) 86 (26.2) 77 (23.5) 64 (19.5) 58 (17.7) 300 (87.8) 115 (35.1) 99 (30.2) 88 (26.8) 74 (22.6) 66 (20.1) 350 (102.5) 120 (36.6) 105 (32.0) 94 (28.7) 79 (24.1) 71 (21.6) 400 (117.1) 125 (38.1) 110 (33.5) 100 (30.5) 84 (25.6) 75 (22.9) 350 (102.5) 130 (39.6) 115 (35.1) 103 (31.4) 88 (26.8) 81 (24.7) 400 (117.1) 138 (42.1) 120 (36.6) 108 (32.9) 94 (28.7) 85 (25.9) Notes: 1. All throw data figures are approximate. 2. — = not recommended at these mounting heights. 3. Nozzles are not available on units below size 100 MBh. 4. Nozzles are available for high-efficiency units. Specify High Efficiency when ordering due to difference in nozzle configuration. Figure 7. Table 5. 60° nozzle 60-degree nozzle—approximate distance of throw at nominal airflow Distance From Floor to Bottom of Unit “H” ft (m) 8 (2.4) 10 (3.0) 12 (3.7) 15 (4.6) 20 (6.1) UH-PRC002-EN 100 (29.3) 75 (22.9) 65 (19.8) 60 (18.3) 50 (15.2) — 125 (36.6) 80 (24.4) 70 (21.3) 64 (19.8) 54 (16.5) 49 (14.9) 150 (43.9) 85 (25.9) 75 (22.9) 68 (20.7) 56 (17.1) 52 (15.8) 175 (51.2) 90 (27.4) 79 (24.1) 72 (21.9) 61 (18.6) 55 (16.8) Unit Size Input MBh (kW) 200 225 (58.6) (65.9) 95 100 (29.0) (30.5) 83 88 (25.3) (26.8) 76 80 (23.2) (24.4) 65 68 (19.8) (20.7) 59 61 (18.0) (18.6) 250 (73.2) 110 (33.5) 95 (29.0) 84 (25.6) 71 (21.6) 65 (19.8) 300 (87.8) 125 (38.1) 109 (33.2) 100 (30.5) 85 (25.9) 77 (23.5) 21 General Data Figure 8. 90° nozzle Table 6. 22 90-degree nozzle—approximate floor coverage at nominal airflow Unit Size 100 10 (3.0) — 125 — 150 — 175 — 200 — 225 — 250 — 300 — 350 — 400 — Distance From Floor to Bottom of Unit “H” ft (m) 15 20 25 (4.6) (6.1) (7.6) 30 x 25 — — (9.1 x 7.6) 35 x 30 — — (10.7 x 9.1) 40 x 35 — — (12.2 x 10.7) 45 x 40 — — 13.7 x 12.2) 50 x 40 40 x 35 — (15.2 x 12.2) (12.2 x 10.7) 55 x 40 48 x 35 — (16.8 x 12.2) (14.6 x 10.7) 60 x 45 56 x 40 50 x 35 (18.3 x 13.7) (17.1 x 12.2) (15.2 x 10.7) 70 x 45 65 x 40 60 x 35 (21.3 x 13.7) (19.8 x 12.2) (18.3 x 10.7) 80 x 50 70 x 45 65 x 40 (24.4 x 15.2) (21.3 x 13.7) (19.8 x 12.2) 100 x 50 80 x 45 75 x 40 (30.5 x 15.2) (24.4 x 13.7) (22.9 x 12.2) 30 (9.1) — — — — — — — 55 (16.8 60 (18.3 65 (19.8 x x x x x x 35 10.7) 35 10.7) 40 12.2) UH-PRC002-EN General Data Figure 9. “Y” splitter Table 7. “Y” splitters—approximate distance of throw at nominal airflow Unit Size Distance From Input MBh (kW) Floor to Bottom of Unit “H” 100 125 150 175 200 225 250 ft (m) (29.3) (36.6) (43.9) (51.2) (58.6) (65.9) (73.2) 8 47 51 60 65 70 72 80 (2.4) (14.3) (15.5) (18.3) (19.8) (21.3) (21.9) (24.4) 10 41 44 52 56 61 63 69 (3.0) (12.5) (13.4) (15.8) (17.1) (18.6) (19.2) (21.0) 12 37 40 47 51 55 57 63 (3.7) (11.3) (12.2) (14.3) (15.5) (16.8) (17.4) (19.2) Notes: 1. All throw data figures are approximate. 2. Nozzles are not available on units below size 100 MBh. 3. Nozzles are available for high-efficiency units. Specify High Efficiency when ordering due to difference in nozzle UH-PRC002-EN 300 (87.8) 95 (29.0) 82 (25.0) 75 (22.9) 350 (102.5) 100 (30.5) 87 (26.5) 79 (24.1) 400 (117.1) 103 (31.4) 92 (28.0) 82 (25.0) configuration. 23 Performance Data Table 8. Correction factors for high altitude installations Altitude Above Sea Level (ft) 0 2,000 3,000 4,000 5,000 Gas Heating Capacity 1.00 0.92 0.88 0.84 0.8 Fan rpm 1.00 1.04 1.06 1.09 1.12 Fan bhp 1.00 1.07 1.12 1.18 1.25 Notes: 1. For high altitude installations above 2,000 feet, reduce ratings 4 percent for each 1,000 feet above sea level. 2. Multiply standard unit by correction factor to get actual input and required rpm and hp. Table 9. 7,000 0.72 1.19 1.41 Tubular Heat Exchanger performance data—model GTND/GTPD Unit Size 003 004 006 007 Input MBh 30 45 60 75 kW 8.8 13.2 17.6 22.0 Output MBh 24.9 37.35 49.8 61.5 kW 7.2 10.9 14.5 18.0 Thermal Efficiency 83 83 83 82 Free Air Delivery cfm 370 550 740 920 0.175 0.260 0.349 0.434 m3/s Air Temperature Rise °F 60 60 60 60 °C 15 15 15 15 Full Load Amps at 120V 3.0 3.0 4.1 4.1 Motor Data hp 1/20 1/20 1/12 1/12 kW 0.04 0.04 0.06 0.06 Type SP SP SP SP rpm 1,650 1,650 1,050 1,050 Amps at 115V 1.9 1.9 2.6 2.6 Notes: 1. Ratings are shown for elevations up to 2,000 feet above level. 2. CS = Capacitor Start; SPH = Split Capacitor 3. Standard motors are 115/60/1 open drip-proof. 4. 0.2 maximum external static pressure. 5. Unit amps are based on hot surface pilot ignition. 24 6,000 0.76 1.15 1.33 009 011 120 015 017 020 025 030 035 040 90 26.4 105 30.8 120 35.2 150 43.9 175 51.2 200 58.6 250 73.2 300 87.8 350 102.5 400 117.1 73.8 21.6 82 86.1 25.2 82 98.4 28.8 82 124.5 36.4 83 145.25 42.5 83 166.0 48.6 83 207.5 60.7 83 249.0 72.9 83 290.5 85.1 83 332.0 97.2 83 1,100 0.519 1,300 0.614 1,475 0.696 2,400 1.133 2,850 1.346 3,200 1.511 3,450 1.629 5,000 2.361 5,600 2.644 5,800 2.738 60 15 6.4 60 15 6.4 60 15 6.4 47 26 5.8 46 26 8.0 47 26 8.0 54 30 8.0 45 25 11.3 47 26 13.5 51 28 13.5 1/10 0.075 SP 1,050 4.2 1/10 0.075 SP 1,050 4.2 1/10 0.075 SP 1,050 4.2 1/4 0.19 PSC 1,140 4.7 1/3 0.25 PSC 1,140 5.8 1/3 0.25 PSC 1,140 5.8 1/3 0.25 PSC 1,140 5.8 1/4 0.19 PSC 1,140 9.4 1/3 0.25 PSC 1,140 11.6 1/3 0.25 PSC 1,140 11.6 sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea UH-PRC002-EN Performance Data Table 10. High Efficiency Propeller Fan Gas Unit Heater performance data—model GHND/GHPD Unit Size 010 012 015 017 020 022 025 030 035 040 Input MBh 100 125 150 175 200 225 250 300 350 400 kW 29.3 36.6 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Output MBh 80 100 120 140 160 120 200 240 280 320 kW 23.4 29.3 35.1 41.0 46.9 52.7 58.6 70.3 82.0 93.7 Thermal Efficiency 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% Free Air Delivery cfm 1,480 1,650 2,200 2,530 2,640 2,700 3,100 4,400 5,000 5,300 0.699 0.779 1.038 1.194 1.246 1.274 1.463 2.077 2.360 2.502 m3/s Air Temperature Rise °F 50 56 50 51 56 61 60 50 52 56 °C 28 31 28 28 31 34 33 28 29 31 Output Velocity fpm 775 910 1,045 1,070 1,010 950 980 1,100 1,150 1,050 m/s 3.94 4.62 5.31 5.44 5.13 4.83 4.98 5.59 5.84 5.33 Full Load Amps at 115V 5.8 6 7.2 8.2 8.2 8.2 8.2 11.2 13.2 13.2 Motor Data hp 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2) 1/4 (2) 1/3 (2) 1/3 kW 0.037 0.075 0.186 0.249 0.249 0.249 0.249 (2) 0.186 (2) 0.249 (2) 0.249 Type SP SP PSC PSC PSC PSC PSC PSC PSC PSC rpm 1,050 1,050 1,140 1,140 1,140 1,140 1,140 1,140 1,140 1,140 Amps at 115V 2.6 2.8 4.0 4.5 4.5 4.5 4.5 8.0 9.0 9.0 Notes: 1. Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2. Standard 115/60/1 open drip-proof motor. 3. The flue vent fan motors used on all high efficiency units are 115/60/1; 1/20 hp and 1.5 amps. Table 11. High Efficiency Centrifugal Fan Unit Heater performance data—model GBND/GBPD Unit Size 010 012 015 017 020 022 025 030 035 040 Input MBh 100 125 150 175 200 225 250 300 350 400 kW 29.3 36.6 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Output MBh 80 100 120 140 160 180 200 240 280 320 kW 23.4 29.3 35.1 41.0 46.9 52.7 58.6 70.3 82.0 93.7 Thermal Efficiency 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% Free Air Delivery cfm 1,200 1,575 1,975 2,300 2,400 2,600 2,850 3,950 4,600 4,800 0.566 0.743 0.932 1.086 1.133 1.227 1.345 1.864 2.171 2.266 m3/s Air Temperature Rise °F 62 59 56 56 62 64 65 56 56 62 °C 34 33 31 31 34 36 36 31 31 34 Output Velocity fpm 880 950 1,030 1,045 965 935 930 1,080 1,090 1,000 m/s 4.47 4.83 5.23 5.31 4.90 4.72 4.72 5.49 5.54 5.08 Full Load Amps at 115V 8.3 9.8 10.6 10.6 15.2 15.2 15.2 15.2 18.6 18.6 Motor Data hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1 kW 0.19 0.25 0.37 0.37 0.56 0.56 0.56 0.56 0.75 0.75 Type SHP SHP SHP SHP SHP SHP SHP SHP CS CS rpm 1,725 1,725 1,725 1,725 1,725 1,725 1,725 1,725 1,725 1,725 Amps at 115V 5.1 6.6 7.4 7.4 12.0 12.0 12.0 12.0 15.4 15.4 Notes: 1. Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2. Standard motors are 115V 60 Hz, single-phase open drip-proof. 3. The flue vent fan motors used on all high efficiency units are 115/60/1; 1/20 hp and 1.5 amps. All other voltages will require an additional transformer. 4. SPH = Split Phase; CS = Capacitor Start 5. 0.2” maximum external static pressure. UH-PRC002-EN 25 Performance Data Table 12. Separated Combustion Propeller Fan Gas Unit Heater performance data—model GAND/GAPD Unit Size 010 012 015 017 020 022 025 030 035 040 Input MBh 100 125 150 175 200 225 250 300 350 400 kW 29.3 36.6 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Output MBh 80 100 120 140 160 180 200 240 280 320 kW 23.4 29.3 35.1 41.0 46.9 52.7 58.6 70.3 82.0 93.7 Thermal Efficiency 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% Free Air Delivery cfm 1480 1650 2200 2530 2640 2700 3100 4400 5000 5300 0.699 0.779 1.038 1.194 1.246 1.274 1.463 2.077 2.360 2.502 m3/s Air Temperature Rise °F 50 56 50 51 56 61 60 50 52 56 °C 28 31 28 28 31 34 33 28 29 31 Output Velocity fpm 775 910 1045 1070 1000 950 980 1100 1150 1050 m/s 3.9 4.6 5.3 5.4 5.1 4.8 5.0 5.6 5.8 5.3 Full Load Amps at 115V 5.8 6.0 7.2 7.8 7.8 7.8 8.8 11.2 12.2 12.2 Motor Data hp 1/20 1/10 1/4 1/3 1/3 1/3 1/2 (2) 1/4 (2) 1/3 (2) 1/3 kW 0.037 0.075 0.186 0.249 0.249 0.249 0.373 (2) 0.186 (2) 0.249 (2) 0.249 Type SP SP PSC PSC PSC PSC PSC PSC PSC PSC rpm 1,050 1,050 1,140 1,140 1,140 1,140 1,140 1,140 1,140 1,140 Amps at 115V 2.6 2.8 4.0 4.5 4.5 4.5 5.5 8.0 9.0 9.0 Notes: 1. Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2. Standard motor is 115/60/1 open drip-proof. 3. SP = Shaded Pole; PSC = Permanent Split Capacitor. Table 13. Separated Combustion Centrifugal Fan Gas Unit Heater performance data—model GKND/GKPD Unit Size 010 012 Input MBh 100 125 kW 29.3 36.6 Output MBh 80 100 kW 23.4 29.3 Thermal Efficiency 80% 80% Free Air Delivery cfm 1,200 1,575 0.566 0.743 m3/s Air Temperature Rise °F 62 59 °C 34 33 Output Velocity fpm 880 950 m/s 4.47 4.83 Full Load Amps at 115V 8.3 9.8 Motor Data hp 1/4 1/3 kW 0.19 0.25 Type SPH SPH rpm 1725 1725 Amps at 115V 5.1 6.6 Notes: 1. Ratings are shown for elevations up to 2,000 feet level. 2. Standard motor is 115/60/1 open drip-proof. 3. SPH = Split Phase; CS = Capacitor Start. 26 015 017 020 022 025 030 035 040 150 43.9 175 51.2 200 58.6 225 65.9 250 73.2 300 87.8 350 102.5 400 117.1 120 35.1 80% 140 41.0 80% 160 46.9 80% 180 52.7 80% 200 58.6 80% 240 70.3 80% 280 82.0 80% 320 93.7 80% 1,975 0.932 2,300 1.086 2,400 1.133 2,600 1.227 2,850 1.345 3.950 1.864 4,600 2.171 4,800 2.266 56 31 56 31 62 34 64 36 65 36 56 31 56 31 62 34 1030 5.23 10.6 1045 5.31 10.6 965 4.90 15.2 935 4.75 15.2 930 4.72 15.2 1080 5.49 15.2 1090 5.54 18.6 1000 5.08 18.6 1/2 0.37 SPH 1725 7.4 1/2 0.37 SPH 1725 7.4 3/4 0.56 SPH 1725 12.0 3/4 0.56 SPH 1725 12.0 3/4 0.56 SPH 1725 12.0 3/4 0.56 SPH 1725 12.0 1 0.75 CS 1725 15.4 1 0.75 CS 1725 15.4 above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea UH-PRC002-EN Performance Data Table 14. High Efficiency Indoor Gas Duct Furnace performance data—model GLND/GLPD Input MAX MIN Output MIN Temp. Rise P.D. MAX Temp. Rise P.D. Unit Size MBh °F °C in. of H2O kPa cfm m3/s °F °C in. of H2O Pascals kW MBh kW MBh kW cfm m3/s 010 100 29.3 50 14.6 80 23.4 929 0.438 80 44 0.12 0.03 2469 1.165 30 17 0.85 0.21 012 125 36.6 62.5 18.3 100 29.3 1157 0.546 80 44 0.13 0.03 3086 1.457 30 17 0.85 0.21 015 150 43.9 75 22.0 120 35.1 1389 0.656 80 44 0.15 0.04 3704 1.748 30 17 0.85 0.21 017 175 51.2 87.5 25.6 140 41.0 1620 0.765 80 44 0.14 0.03 4321 2.040 30 17 0.85 0.21 020 200 58.6 100 29.3 160 46.9 1852 0.874 80 44 0.14 0.03 4938 2.331 30 17 0.85 0.21 022 225 65.9 112.5 32.9 180 52.7 2083 0.983 80 44 0.14 0.03 5556 2.622 30 17 0.85 0.21 025 250 73.2 125 36.6 200 58.6 2315 1.093 80 44 0.14 0.03 6173 2.914 30 17 0.85 0.21 030 300 87.8 150 43.9 240 70.3 2778 1.311 80 44 0.13 0.03 7407 3.496 30 17 0.87 0.22 035 350 102.5 175 51.2 280 82.0 3241 1.530 80 44 0.13 0.03 8642 4.079 30 17 0.87 0.22 040 400 117.1 200 58.6 320 93.7 3704 1.748 80 44 0.14 0.03 9877 4.662 30 17 0.90 0.22 Note: Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet input must be derated four percent for each 1,000 feet above sea level. Table 15. Separated Combustion Indoor Gas Duct Furnace performance data—model GMND/GMPD Input MAX MIN Output MIN Temp. Rise P.D. MAX Temp. Rise P.D. Unit Size MBh °F °C in. of H2O kPa cfm m3/s °F °C in. of H2O Pascals kW MBh kW MBh kW cfm m3/s 010 100 29.3 50 14.6 80 23.4 822 0.388 90 50 0.10 0.02 3700 1.746 20 11 2.03 0.51 012 125 36.6 62.5 18.3 100 29.3 1028 0.485 90 50 0.09 0.02 4625 2.183 20 11 1.92 0.48 015 150 43.9 75 22.0 120 35.1 1233 0.582 90 50 0.09 0.02 5550 2.620 20 11 1.81 0.45 017 175 51.2 87.5 25.6 140 41.0 1439 0.679 90 50 0.09 0.02 6475 3.056 20 11 1.86 0.46 020 200 58.6 100 29.3 160 46.9 1645 0.776 90 50 0.09 0.02 7401 3.493 20 11 1.90 0.47 022 225 65.9 112.5 32.9 180 52.7 1850 0.873 90 50 0.09 0.02 8326 3.930 20 11 1.93 0.48 025 250 73.2 125 36.6 200 58.6 2056 0.970 90 50 0.09 0.02 9251 4.366 20 11 1.96 0.49 030 300 87.8 150 43.9 240 70.3 2467 1.164 90 50 0.10 0.02 11101 5.240 20 11 2.00 0.50 035 350 102.5 175 51.2 280 82.0 2878 1.358 90 50 0.10 0.02 12951 6.113 20 11 2.02 0.50 040 400 117.1 200 58.6 320 93.7 3289 1.552 90 50 0.10 0.02 14801 6.986 20 11 2.05 0.51 Note: Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet input must be derated four percent for each 1,000 feet above sea level. UH-PRC002-EN 27 Performance Data Table 16. Horizontal Blower Assembly performance data External Static Pressure 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 in. of H2O kPa 0.05 0.07 0.10 0.12 0.15 0.17 0.20 0.22 cfm hp hp hp hp hp hp hp hp Nominal Blower Models cfm Size rpm kW rpm kW rpm kW rpm kW rpm kW rpm kW rpm kW rpm kW m3/s HBAC-15 1,500 10” 1,250 525 1/3 650 1/3 680 1/3 760 1/3 780 1/3 840 1/3 — — — — 0.590 0.25 0.25 0.25 0.25 0.25 0.25 1,500 600 1/3 680 1/3 715 1/3 790 1/3 810 1/2 860 1/2 895 1/2 970 1/2 0.708 0.25 0.25 0.25 0.25 0.37 0.37 0.37 0.37 1,750 650 1/3 710 1/3 750 1/2 805 1/2 850 1/2 890 1/2 940 3/4 990 3/4 0.826 0.25 0.25 0.37 0.37 0.37 0.37 0.56 0.56 2,000 700 1/2 760 1/2 800 1/2 850 1/2 890 1/2 925 3/4 980 3/4 1,010 3/4 0.944 0.37 0.37 0.37 0.37 0.37 0.56 0.56 0.56 HBAC-20 2,000 12” 1,500 425 1/3 500 1/3 550 1/3 630 1/3 — — — — — — — — 0.708 0.25 0.25 0.25 0.25 1,750 450 1/3 515 1/3 560 1/3 635 1/2 680 1/2 725 1/2 — — — — 0.826 0.25 0.25 0.25 0.37 0.37 0.37 2,000 475 1/3 530 1/3 590 1/2 640 1/2 690 1/2 740 1/2 785 1/2 810 3/4 0.944 0.25 0.25 0.37 0.37 0.37 0.37 0.37 0.56 2,250 515 1/2 560 1/2 610 1/2 650 1/2 700 3/4 750 3/4 790 3/4 815 3/4 1.062 0.37 0.37 0.37 0.37 0.56 0.56 0.56 0.56 2,500 540 1/2 590 1/2 625 1/2 670 1/2 710 3/4 760 3/4 795 3/4 820 3/4 1.180 0.37 0.37 0.37 0.37 0.56 0.56 0.56 0.56 2,750 575 1/2 615 1/2 650 3/4 690 3/4 730 3/4 780 3/4 800 3/4 830 1 1.298 0.37 0.37 0.56 0.56 0.56 0.56 0.56 0.75 HBAC-30 3,000 12” 1,750 450 1/3 510 1/3 560 1/3 630 1/3 675 1/2 720 1/2 — — — — 0.826 0.25 0.25 0.25 0.25 0.37 0.37 2,000 475 1/3 525 1/3 590 1/2 635 1/2 680 1/2 735 1/2 785 1/2 810 3/4 0.944 0.25 0.25 0.37 0.37 0.37 0.37 0.37 0.56 2,250 500 1/2 550 1/2 600 1/2 645 1/2 685 1/2 740 3/4 785 3/4 810 3/4 1.062 0.37 0.37 0.37 0.37 0.37 0.56 0.56 0.56 2,500 525 1/2 580 1/2 615 1/2 665 1/2 700 3/4 750 3/4 790 3/4 815 3/4 1.180 0.37 0.37 0.37 0.37 0.56 0.56 0.56 0.56 2,750 560 1/2 605 1/2 640 3/4 685 3/4 715 3/4 775 3/4 805 3/4 825 1 1.298 0.37 0.37 0.56 0.56 0.56 0.56 0.56 0.75 3,000 610 1/2 640 3/4 660 3/4 710 3/4 750 1 790 1 815 1 845 1 1.416 0.37 0.56 0.56 0.56 0.75 0.75 0.75 0.75 3,250 630 3/4 675 3/4 700 1 735 1 750 1 790 1 830 1 860 1 1.534 0.56 0.56 0.75 0.75 0.75 0.75 0.75 0.75 3,500 675 3/4 700 1 725 1 775 1 800 1 840 1-1/2 875 1-1/2 890 1-1/2 1.652 0.56 0.75 0.75 0.75 0.75 1.12 1.12 1.12 HBAC-45 4,500 12” 2,750 400 3/4 450 3/4 510 3/4 — — — — — — — — — — 1.298 0.56 0.56 0.56 3,000 425 3/4 475 3/4 550 3/4 600 3/4 650 3/4 — — — — — — 1.416 0.56 0.56 0.56 0.56 0.56 3,500 430 3/4 480 3/4 560 3/4 610 3/4 660 3/4 700 1 730 1 — — 1.652 0.56 0.56 0.56 0.56 0.56 0.75 0.75 4,000 450 3/4 500 3/4 565 3/4 615 3/4 670 1 710 1 740 1 790 1 1.888 0.56 0.56 0.56 0.56 0.75 0.75 0.75 0.75 4,500 475 3/4 525 3/4 575 3/4 620 1 680 1 715 1 750 1 800 1-1/2 2.124 0.56 0.56 0.56 0.75 0.75 0.75 0.75 1.12 5,000 500 3/4 540 3/4 600 1 630 1 690 1 720 1-1/2 760 1-1/2 810 1-1/2 2.360 0.56 0.56 0.75 0.75 0.75 1.12 1.12 1.12 5,500 530 1 575 1 615 1 650 1-1/2 700 1-1/2 700 1-1/2 730 1-1/2 820 1-1/2 2.596 0.75 0.75 0.75 1.12 1.12 1.12 1.12 1.12 6,000 575 1-1/2 615 1-1/2 660 1-1/2 690 1-1/2 715 1-1/2 760 2 800 2 830 2 2.832 1.12 1.12 1.12 1.12 1.12 1.49 1.49 1.49 6,500 610 1-1/2 660 2 710 2 750 2 800 2 840 2 890 3 930 3 3.068 1.12 1.49 1.49 1.49 1.49 1.49 2.24 2.24 7,000 720 1-1/2 790 2 830 2 860 2 910 3 940 3 960 3 — — 3.304 1.12 1.49 1.49 1.49 2.24 2.24 2.24 7,500 800 2 860 2 900 3 930 3 960 3 — — — — — — 3.540 1.49 1.49 2.24 2.24 2.24 8,000 860 2 930 3 960 3 — — — — — — — — — — 3.776 1.49 2.24 2.24 Note: External Static Pressure in inches of water. Add pressure drop of indoor duct furnace, if used, to pressure drop of ductwork, to determine total external static pressure. HBAC units are for use with specific duct furnace sizes. Reference Table 29, p. 55. 28 UH-PRC002-EN Performance Data Figure 10. Performance data curves for all duct furnaces UH-PRC002-EN 29 Controls Pilot Control High efficiency units (centrifugal, propeller and duct furnaces) ship as standard with intermittent pilot ignition. The separated combustion propeller and centrifugal fan unit heaters also ship as standard with intermittent pilot ignition. Intermittent pilot ignition contains a solid-state ignition control system that ignites the pilot by spark for each cycle of operation. When the pilot flame is proven, the main burner valve opens to allow gas flow to the burners. Both the pilot and burners are extinguished during the off cycle. Intermittent pilot ignition is ideal for limited access installations where manual lighting of the pilot may be difficult. Nuisance pilot outages on units mounted in areas subject to occasional severe drafts can also be eliminated. Energy savings will be realized using this system as the pilot is extinguished during the off cycle. Intermittent pilot ignition should be considered on units that have long shutoff periods. Fan Control The supply fan motor is activated directly through the fan time delay relay on indoor units provided with single-phase motors up to one hp. Contactors or starters are required on all other units with single-phase motors, 1-1/2 hp and above, and with all three-phase motors. On indoor units, contactors and starters, where required, are provided (see Table 17.) Table 17. Contactors provided on indoor units hp Voltage 1/2 3/4 1 1-1/2 2 3 5 7-1/2 10 115/60/1 1 1 1 2 2 N/A N/A N/A N/A 230/60/1 1 1 1 2 2 N/A N/A N/A N/A 208/60/3 2 2 2 2 2 2 2 4 4 230/60/3 2 2 2 2 2 2 2 4 4 460/60/3 3 3 3 3 3 3 3 5 5 Notes: 1. Contactors not required or provided on units with single phase motors up to one hp. 2. Provided with contactor with line voltage holding coil on all 1-1/2 hp and above single-phase motors and on all 208/230V three-phase motors up to five hp. 3. Provided with contactor with low (24V) holding coil on all 460 V three-phase motors up to five hp. 4. Provided with size 2 starter on all units with 7-1/2 and 10 hp 208/230V three-phase motors. 5. Provided with size 1 starter on all units with 7-1/2 and 10 hp 460V three-phase motors. Gas Controls Single-Stage Control Indoor gas heating units are provided with an automatic single-stage gas valve as standard. This valve is an on/off type control, typically activated by a low voltage single-stage thermostat. Two-Stage Control Indoor units with optional two-stage control are provided with a two-stage gas valve capable of firing at 100 percent and 50 percent of rated input. Ignition is at low fire (50 percent of the unit’s rated input) and the unit is typically controlled by a low voltage two-stage thermostat. Electronic Modulating Control This optional control is available for use with natural gas units only. Units with electronic modulating control are provided with an electronic modulating valve capable of firing from 100 percent to 50 percent of rated input. Ignition is at full fire (100 percent of unit’s rated input). The electronic modulating valve is controlled by a room thermostat or a duct thermostat with remote setpoint adjustment which modulates the gas input from 100 percent to 50 percent of rated input. An optional override room thermostat is available for use with the duct thermostat. The override room thermostat allows full fire and overrides the duct thermostat when the room temperature falls below the override room thermostat’s setpoint. Note: N/A on 30–75 MBh units. 30 UH-PRC002-EN Controls Electronic Modulating, 4–20 mA/0–10 Vdc Input Provides modulated heat output. Ignition is at full fire (100 percent input), and modulates the gas input from 100 percent to 40 percent rated input. The modulating gas valve shall operate in response to a 4–20 mA or a 0–10 Vdc input from an external DDC control. UH-PRC002-EN 31 Controls Thermostats Electronic Modulating Room Thermostat (Included with Gas Control) • Low Voltage (24 V) • 60 to 85°F Range • 5-13/16” W 3-1/4” H 1-7/8” D • Natural Gas Only Single-Stage Room Thermostat (Order No. 350-0015-01) • Low Voltage (24 V) • 55 to 95°F Range • 2-7/8” W x 4-3/4” H x 1-1/8” D Single-Stage Duct Thermostat (Order No. 350-0015-07) • Low Voltage (24 V) • 55 to 175°F Range • 5’ Capillary • 2” W x 5-5/8” H x 2-7/16” D Electronic Modulating Duct Thermostat (Included with Gas Control) • Low Voltage (24 V) • 55 to 90°F Range • Sensor: 10-inch Probe • Remote Temperature Selector: 4-1/4” W 4-1/4” H 1-7/8” D • Duct Thermostat: 4-1/4” W 4-1/4” H 1-5/8” D • Natural Gas Only Single-Stage Room Thermostat with Summer/Winter Switch (Order No. 350-0015-02) • Low Voltage (24 V) • 55 to 95°F Range • Fan Auto-On Switch • 3-1/2” W x 4-1/5” H x 1-3/8” D Two-Stage Duct Thermostat Order No. 350-0015-08) • Low Voltage (24 V) • 55 to 175°F Range • 5’ Capillary • 2” W x 5-5/8” H x 2-7/16” D Electronic Modulating Override Room Thermostat for use with Duct Thermostats (Order No. 350-0015-05) • Line Voltage (115 V) • 50 to 90°F Range • 2-7/8” W 4-9/16” H 1-1/4” D • Natural Gas Only Two-Stage Room Thermostat (Order No. 0135-THT025320-01, or 0135-THT02532G-01 with guard) • Low Voltage (24 V) • 42 to 88°F Range • Fan Auto-On Switch • System Off-Auto Switch • 5-5/8” W x 3-1/2” H x 2-1/8” D Universal Guard (Order No. 350-0015-06) • Clear Plastic • Ring Base • Tumbler Lock and Two Keys • Cover: 6-7/8” W x 5-5/8” H x 3” D • Base: 6-9/16” W x 5-1/2” H x 3/8” D 32 UH-PRC002-EN Sequence of Operations Typical wiring diagrams and sequence of operations for indoor units with intermittent pilot ignition or direct spark ignition are included in this section. On duct furnaces, the fan motor and associated controls shown in the wiring diagrams are not integral to the unit. It is essential, however, that the air handling system be interlocked with the duct furnace to prevent duct furnace operation without airflow. Single-Stage Control With power applied to the unit: 1. The thermostat calls for heat. 2. The pilot valve opens. 3. The ignitor sparks continuously to ignite the pilot. 4. The sensor proves pilot ignition and shuts off the ignitor. 5. With the pilot lit, the main gas valve opens. 6. Main burners are lit at 100 percent of unit’s rated input. 7. The fan time delay relay (optional on duct furnaces) allows the heat exchanger to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor.1 8. The unit continues to fire until the thermostat is satisfied and no longer calls for heat. 9. The main and pilot valves close. 10. The fan time delay relay remains closed, keeping the fan operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. Note: This unit is equipped with a blocked vent shutoff (spill) switch. If the venting system becomes blocked or there is continuous spillage, the vent shutoff switch will shut off the unit heater. 1 UH-PRC002-EN • Caution - Disconnect power before servicing. • Unit must be grounded. • Use copper conductors only. • If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 125°C. • Refer to installation instructions for venting, gas piping, and start-up procedures. • - - - Indicates Field Wiring. • ___ Indicates Factory Wiring. See “Fan Control,” p. 30. 33 Sequence of Operations Two-Stage Control With power applied to the unit: 1. The first stage of the thermostat calls for heat. 2. The pilot valve opens. 3. The ignitor sparks continuously to ignite the pilot. 4. The sensor proves pilot ignition and shuts off the ignitor. 5. With the pilot lit, the main gas valve opens to low fire. 6. Main burners are lit at 50 percent of unit’s rated input. 7. The fan time delay relay (optional on duct furnaces) allows the heat exchanger to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor.1 8. If additional heat is required, the second stage of the thermostat calls for heat. 9. The main gas valve opens to full fire. The main burners are now at full fire. The unit continues at full fire until the second stage of the thermostat is satisfied and no longer calls for heat. 10. The main valve closes to low fire. The main burners are now at low fire. The unit continues at low fire until the first stage of the thermostat is satisfied and no longer calls for heat. 11. The main and pilot valves close. 12. The fan time delay relay remains closed, keeping the fan operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. Note: This unit is equipped with a blocked vent shutoff (spill) switch. If the venting system becomes blocked or there is continuous spillage, the vent shutoff switch will shut off the unit heater. 1 34 • Caution - Disconnect power before servicing. • Unit must be grounded. • Use copper conductors only. • If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 125°C. • High-limit and blocked vent (spill) wires minimum 200°C. • Refer to installation instructions for venting, gas piping, and start-up procedures. • - - - Indicates Field Wiring. • ___ Indicates Factory Wiring. See “Fan Control,” p. 30. UH-PRC002-EN Sequence of Operations Electronic Modulating Control (with duct thermostat) With power applied to the unit: 1. The thermostat calls for heat. 2. The pilot valve opens. 3. The ignitor sparks continuously to ignite the pilot. 4. The sensor proves pilot ignition and shuts off the ignitor. 5. With the pilot lit, the gas valve opens. 6. Main burners are lit at 100 percent of unit’s rated input. 7. The fan time delay relay (optional on duct furnaces) allows the heat exchanger to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor. 8. The unit is controlled by the duct thermostat which modulates the unit from 100 to 50 percent of unit’s rated input. An amplifier receives a small electrical signal from the thermostat and converts this into a working voltage. This working voltage determines the position of the modulating valve. With no voltage applied to the valve, the valve will be full open and full fire will occur. As increasing voltage is applied to the valve, the valve will modulate closed. At approximately 12V dc, the valve will be at its minimum low fire position. If the voltage continues to increase, indicating a further reduction in the unit’s firing is required, the increased voltage closes a relay which closes the automatic gas valve. As temperature drops, the voltage also drops causing the relay to re-open the valve. The unit will continue to cycle in this manner until either an increase in the unit’s firing rate is required or the thermostat is satisfied and no longer calls for heat. 9. When the thermostat is satisfied, the main and pilot valves close. 10. The fan time delay relay (optional on duct furnaces) remains closed keeping the fan motor operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. 11. If optional room override thermostat is ordered…when setpoint is reached, it will cause the unit to go to full-fire, overriding both the duct sensor and the remote setpoint adjustment. Note: Sensor and selector wires to amplifier must not be run close to, or in conduit with, power or ignition wires. UH-PRC002-EN 35 Sequence of Operations Electronic Modulating Control (with Duct Thermostat) LINE IN 115V/1/60 L2 L2 L1 L1 BLOWER MOTOR 8 FAN TIME DELAY DISCONNECT BLACK SUMMER/WINTER SWITCH W K5 DRAFTOR HTR BLACK 8 S DRAFTOR WIRING FOR POWER VENTED UNITS L2 L1 LINE 24V XFORMER 50 VA 1 1 2 2 FAN TIME DELAY DL FURNACE ONE HIGH LIMIT 1 24 VOLTS R1 3 2 DL W1 V DRAFTOR END SW 58600 IGNITOR MV SOL. MV MV/PV PV SOL. PV GND 24V (GND) 2 BLKD. VENT 1 2 K5 2 V MAXITROL TS121 TD121 W/ DUCT SENSING 1 4 5 t˚ 7 3 14 MR1 24V (HOT) SPARK IGN W1 DL 1 1 DRAFTOR ONE 2 1 9 10 8 11 ONE USE HR VALVE A1010 FOR PER SINGLE FUNACE FURNACE A1011 FOR SECTION MULTIPLE FURNACE 2 36 UH-PRC002-EN Sequence of Operations Electronic Modulating Control (with room thermostat) With power applied to the unit: 1. The thermostat calls for heat. 2. The pilot valve opens. 3. The ignitor sparks continuously to ignite the pilot. 4. The sensor proves pilot ignition and shuts off the ignitor. 5. With the pilot lit, the gas valve opens. 6. Main burners are lit at 100 percent of unit’s rated input. 7. The fan time delay relay (optional on duct furnaces) allows the heat exchanger to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor.1 8. The unit is controlled by the electronic thermostat which modulates the unit from 100 to 50 percent of unit’s rated input. An amplifier receives a small electrical signal from the thermostat and converts this into a working voltage. This working voltage determines the position of the modulating valve. With no voltage applied to the valve, the valve will be full open and full fire will occur. As increasing voltage is applied to the valve, the valve will modulate closed. At approximately 12 Vdc, the valve will be at its minimum low fire position. If the voltage continues to increase, indicating a further reduction in the unit’s firing is required, the increased voltage closes a relay which closes the automatic gas valve. As temperature drops, the voltage also drops causing the relay to re-open the valve. The unit will continue to cycle in this manner until either an increase in the unit’s firing rate is required or the thermostat is satisfied and no longer calls for heat. 9. When the room thermostat is satisfied, the main and pilot valves close. 10. The fan time delay relay (optional on duct furnaces) remains closed keeping the fan motor operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. 1 UH-PRC002-EN See “Fan Control,” p. 30. 37 Sequence of Operations Electronic Modulating Control (with room thermostat) L2 LINE IN 115V/1/60 L2 L1 L1 BLOWER MOTOR 8 FAN TIME DELAY DISCONNECT 8 SUMMER/WINTER SWITCH S W L2 L1 BLACK K5 BLACK 1 1 115V TO 24V XFORMER 50 VA 2 DL R1 3 2 2 FAN TIME DEALY DL FURNACE ONE HIGH LIMIT 1 24 VOLTS DRAFTOR MTR W1 DRAFTOR ONE K5 V 58600 IGNITOR MV SOL. MV MV/PV PV SOL. PV GND 24V (GND) 2 PRESS. SW. 24V (HOT) SPARK MR1 3 T107A TSTAT V 2 IGN W1 DL 1 1 MAXITROL W/ROOM SENSING 4 1 3 7 5 9 7 9 10 8 11 1 ONE USE HR VALVE A1010 FOR PER SINGLE FURNACE FURNACE A1011 FOR SECTION MULTIPLE FURNACE 2 2 38 UH-PRC002-EN Sequence of Operations High-Efficiency Units Note: On duct furnaces, the fan motor and associated controls shown in the wiring diagrams are not integral to the unit. It is essential, however, that the air handling system be interlocked with the duct furnace to prevent duct furnace operation without airflow. Single-Stage Control, Intermittent Pilot With power applied to the unit: 1. The thermostat calls for heat. 2. The pressure switch measures the flow through the vent system and energizes the intermittent pilot when the flow is correct. Important: CAUTION: THE PRESSURE SWITCH MUST NOT BE BYPASSED. THE UNIT MUST NOT BE FIRED UNLESS THE FLUE VENT FAN IS OPERATING. If this procedure is not followed, there may be a gas buildup that could cause an explosion. 3. The pressure switch closes and activates the flue vent fan. 4. The pilot valve opens. 5. The ignitor sparks continuously to ignite the pilot. 6. The sensor proves pilot ignition and shuts off the ignitor. 7. With the pilot lit, the main gas valve opens. 8. Main burners are lit at 100 percent of the unit’s rated input. 9. The fan time delay relay allows the heater to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor.1 10. The unit continues to fire until the thermostat is satisfied and no longer calls for heat. 11. The main and pilot valve close. 12. The fan time delay relay remains closed, keeping the fan operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. L2 • Caution - Disconnect power before servicing. • Unit must be grounded. LINE IN 115-240/1/60 L1 L1 TIME DELAY L1 SUMMER 8 BLOWER MOTOR L2 • Use copper conductors only. • If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 125°C. • High-limit wires minimum 200°C. • Refer to installation instructions for venting, gas piping and start-up procedures. • - - - Indicates Field Wiring. • ___ Indicates Factory Wiring. WINTER RELAY 1 L1 DRAFTOR MTR. 1 R THERMOSTAT R W HIGH LIMIT W 3 2 1 2 L2 T1 115-240/24V 50VA DRAFTOR PRESS. SW. 58600 IGNITOR MV MV SOL. MV/PV PV SOL. PV GND 24V (GND) 24V (HOT) SPARK IGN RELAY 1 R TIME DELAY TD 1 UH-PRC002-EN See “Fan Control,” p. 30. 39 Sequence of Operations Two-Stage Control, Intermittent Pilot With power applied to the unit: 1. The first stage of the thermostat calls for heat. 2. The pressure switch measures the flow through the vent system and energizes the intermittent pilot when the flow is correct. Important: CAUTION: THE PRESSURE SWITCH MUST NOT BE BYPASSED. THE UNIT MUST NOT BE FIRED UNLESS THE FLUE VENT FAN IS OPERATING. If this procedure is not followed, there may be a gas buildup that could cause an explosion. 3. The pressure switch closes and activates the flue vent fan. 4. The pilot valve opens. 5. The ignitor sparks continuously to ignite the pilot. 6. The sensor proves pilot ignition and shuts off the ignitor. 7. With the pilot lit, the main gas valve opens to low fire. 8. Main burners are lit at 50 percent of unit's rated input. 9. The fan time delay relay allows the heater to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor.1 10. If additional heat is required, the second stage of the thermostat calls for heat. 11. The main gas valve opens to full fire. The main burners are now at full fire. The unit continues at full fire until the second stage of the thermostat is satisfied and no longer calls for heat. 12. The main valve closes to low fire. The main burners are now at low fire. The unit continues at low fire until the first stage of the thermostat is satisfied and no longer calls for heat. 13. The fan time delay relay remains closed, keeping the fan operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. 1 40 • Caution - Disconnect power before servicing. • Unit must be grounded. • Use copper conductors only. • If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 125°C. • High-limit wires minimum 200°C. • Refer to installation instructions for venting, gas piping and start-up procedures. • - - - Indicates Field Wiring. • ___ Indicates Factory Wiring. See “Fan Control,” p. 30. UH-PRC002-EN Sequence of Operations Single-Stage Control, Direct Spark With power applied to the unit: 1. The thermostat calls for heat. 2. The power venter is energized and the pressure switch measures the flow through the vent system and energizes the direct spark ignition system beginning the pre-purge timing when the flow is correct. Important: CAUTION: THE PRESSURE SWITCH MUST NOT BE BYPASSED. THE UNIT MUST NOT BE FIRED UNLESS THE FLUE VENT FAN IS OPERATING. If this procedure is not followed, there may be a gas buildup that could cause an explosion. 3. The direct spark ignition lights the main gas. The sensing device has seven seconds to prove flame. 4. The fan time delay in the board allows the heater to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor.1 5. The unit continues at full fire until the thermostat is satisfied and no longer calls for heat. 6. The main valve closes. 7. 1 UH-PRC002-EN The fan time delay relay remains closed, keeping the fan operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. • Caution - Disconnect power before servicing. • Unit must be grounded. • Use copper conductors only. • If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 125°C. • High-limit wires minimum 200°C. • Refer to installation instructions for venting, gas piping and start-up procedures. • - - - Indicates Field Wiring. • ___ Indicates Factory Wiring. See “Fan Control,” p. 30. 41 Sequence of Operations Two-Stage Control, Direct Spark With power applied to the unit: 1. The thermostat calls for heat. 2. The power venter is energized and the pressure switch measures the flow through the vent system and energizes the direct spark ignition system beginning the pre-purge timing when the flow is correct. Important: CAUTION: THE PRESSURE SWITCH MUST NOT BE BYPASSED. THE UNIT MUST NOT BE FIRED UNLESS THE FLUE VENT FAN IS OPERATING. If this procedure is not followed, there may be a gas buildup that could cause an explosion. 3. The direct spark ignition lights the first stage main gas. The sensing device has seven seconds to prove flame. Main burners are lit at 50 percent of unit's rated input. 4. The fan time delay in the board allows the heater to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor.1 5. If additional heat is required, the second stage of the thermostat calls for heat. 6. The main gas valve opens to full fire. The main burners are now at full fire. The unit continues at full fire until the second stage of the thermostat is satisfied and no longer calls for heat. 7. The main valve closes to low fire. The main burners are now at low fire. The unit continues at low fire until the first stage of the thermostat is satisfied and no longer calls for heat. 8. The gas valve closes. 9. The fan time delay relay remains closed, keeping the fan operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. 1 42 • Caution - Disconnect power before servicing. • Unit must be grounded. • Use copper conductors only. • If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 125°C. • High-limit wires minimum 200°C. • Refer to installation instructions for venting, gas piping and start-up procedures. • - - - Indicates Field Wiring. • ___ Indicates Factory Wiring. See “Fan Control,” p. 30. UH-PRC002-EN Sequence of Operations Separated Combustion Units Single-Stage Control With power applied to the unit: 1. The thermostat calls for heat. 2. The pressure switch measures the pressure differential between the air inlet and exhaust vent systems. If the differential is correct, the intermittent pilot ignition is energized. Important: CAUTION: THE PRESSURE SWITCH MUST NOT BE BYPASSED. THE UNIT MUST NOT BE FIRED UNLESS THE FLUE VENT FAN IS OPERATING. 3. When the pressure switch is closed, the power venter motor is energized. 4. The pilot valve opens. 5. The ignitor sparks continuously to ignite the pilot. 6. The sensor proves pilot ignition and shuts off the ignitor. 7. With the pilot lit, the main gas valve opens. 8. Main burners are lit at 100 percent of the unit’s rated input. 9. The fan time delay relay allows the heater to come up to operating temperature. At this time, the fan time delay relay closes and activates the fan motor.1 10. The unit continues to fire until the thermostat is satisfied and no longer calls for heat. 11. The main and pilot valve close. 12. The pressure switch opens and deactivates the gas control. 13. The fan time delay relay remains closed, keeping the fan operating to dissipate residual heat from the heat exchanger. At this time, the fan time delay relay opens and deactivates the fan motor. 8 FAN TIME DELAY L1 L1 BLOWER/FAN MOTOR L2 LINE IN 115/1/60 L2 DISCONNECT DRAFTOR MOTOR BLACK W Caution - Disconnect power before servicing. • Unit must be grounded. MTR • Use copper conductors only. • If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 125°C. • High-limit wires minimum 200°C. • Refer to installation instructions for venting, gas piping and start-up procedures. • - - - Indicates Field Wiring. • ___ Indicates Factory Wiring. S L2 L1 1 K5 BLACK 8 SUMMER/WINTER SWITCH • MTR 1 LINE TO 24V XFORMER 50 VA 24 VOLTS 2 2 FAN TIME DELAY DL DL HIGH LIMIT 1 R1 3 2 1 W1 DRAFTOR ONE K5 V 58600 IGNITOR MV MV SOL. MV/PV PV SOL. PV GND 24V (GND) 2 PRESS. SW. 1 W1 DL V 2 1 24V (HOT) SPARK IGN T/D STAT R 1 UH-PRC002-EN W/B See “Fan Control,” p. 30. 43 Sequence of Operations Separated Combustion Units—Single-Stage Control—Electronic Modulating 4–20 mA/0–10 Vdc Input 44 UH-PRC002-EN Electrical Data Table 18. Motor electrical data—centrifugal fan Full Load Amps(a) Current Characteristics 1/4 hp 1/3 hp 1/2 hp 3/4 hp 115/60/1 5.0 5.9 7.2 11.0 230/60/1 2.5 3.3 3.9 5.5 208/60/3 NR NR 2.7 3.1 230/60/3 NR NR 2.4 2.8 460/60/3 NR NR 1.2 1.4 Note: NR = Motor available, but not rated by NEC. 1 hp 14.0 7.0 4.0 3.6 1.8 (a) FLA based on NEC ratings. All motors are 1,725 rpm. Table 19. Motor electrical data—horizontal blower Full Load Amps(a) Current Characteristics 1/2 hp 1/2 hp 3/4 hp 1 hp 1-1/2 hp 115/60/1 5.9 7.2 11.0 14.0 16.4 230/60/1 3.3 3.9 5.5 7.0 8.2 208/60/3 NR 2.7 3.1 4.0 4.9 230/60/3 NR 2.4 2.8 3.6 4.4 460/60/3 NR 1.2 1.4 1.8 2.2 Motor weight (lb) 18 33 33 36 39 Note: NR = Motor available, but not rated by NEC. 2 hp 24.6 12.3 6.4 5.8 2.9 40 3 hp 34.0 17.0 9.2 8.6 4.3 44 (a) FLA based on NEC ratings. All motors are 1,725 rpm. UH-PRC002-EN 45 Dimensions and Weights Table 20. Tubular Heat Exchanger dimensional data—model GTND/GTPD Unit Sizes “A” Jacket Height “B” Overall Height "C" Overall Depth “D1” Center Line Height of Flue “D2” Center Line Height of Air Intake “E” Fan Diameter “F” Discharge Opening Height “G” Vent Connection Diameter “H1” Center Line of Flue Connection From Side “H2” Center Line of Air Intake From Side Flue Size Requirements Category I Horizontal(a) in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm 30 12-3/8 314 13-1/4 337 25-7/8 632 8-1/2 216 8-1/2 216 10 254 10-13/16 275 4 102 7-1/4 184 2-3/4 70 45 12-3/8 314 13-1/4 337 25-7/8 632 8-1/2 216 8-1/2 216 10 254 10-13/16 275 4 102 7-1/4 184 2-3/4 70 60 15-7/8 403 16-13/16 427 26-3/16 665 10-3/8 364 8 203 14 356 14-7/16 367 4 102 7-1/4 184 2-3/4 70 in. 4 4 mm 102 102 Category III Horizontal in. 4 4 mm 102 102 Category I & III Vertical in. 4 4 mm 102 102 Unit Weight lb 60 65 kg 27 29 Shipping Weight lb 70 75 kg 32 34 Note: For all installations, the flue collar is included with the unit and should be field 75 15-7/8 403 16-13/16 427 26-3/16 665 10-3/8 364 8 203 14 356 14-7/16 367 4 102 7-1/4 184 2-3/4 70 90 22-5/8 574 23-9/16 598 26-3/8 670 13-5/8 346 8-5/8 219 16 406 21-3/16 538 4 102 7-3/4 197 3-1/2 89 105 22-5/8 574 23-9/16 598 26-3/8 670 13-5/8 346 8-5/8 219 16 406 21-3/16 538 4 102 7-3/4 197 3-1/2 89 120 22-5/8 574 23-9/16 598 26-3/8 670 13-5/8 346 8-5/8 219 16 406 21-3/16 538 4 102 7-3/4 197 3-1/2 89 4 5 5 5 5 102 127 127 127 127 4 4 4 4 4 102 102 102 102 102 4 4 4 4 4 102 102 102 102 102 80 85 95 105 110 36 39 43 48 50 90 95 110 115 120 41 43 50 52 54 installed per the instructions included with the unit. (a) 4–5” reducer supplied where required. 46 UH-PRC002-EN Dimensions and Weights Table 21. Tubular Heat Exchanger unit heater dimensional data—model GTND/GTPD Model 015 017 020 025 Input MBh 150.0 A B C D E F G H L Diameter Flue Fan Gas Inlet Nat. LP Weight Unit Shipping in. mm 33-3/4 20-3/4 13-3/8 857 527 340 11 279 18-5/8 18-3/4 473 476 4-3/4 121 24-1/2 25-1/4 622 641 5 127 16 1/2 1/2 lb kg 155 70 195 88 in. mm 33-3/4 32-3/4 19-3/8 857 831 492 11 279 30-5/8 30-3/4 778 781 4-3/4 121 24-1/2 37-1/4 622 946 5 127 18 1/2 1/2 lb kg 191 87 241 109 in. mm 33-3/4 32-3/4 19-3/8 857 831 492 11 279 30-5/8 30-3/4 778 781 4-3/4 121 24-1/2 37-1/4 622 946 5 127 18 1/2 1/2 lb kg 201 91 251 114 in. mm 33-3/4 32-3/4 19-3/8 857 831 492 11 279 30-5/8 30-3/4 778 781 4-3/4 121 24-1/2 37-1/4 622 946 5 127 18 3/4 1/2 lb kg 211 96 261 118 175.0 200.0 250.0 1. Rear view 2. Side view 3. Front view Dimensions are in inches. Dimensions in ( ) are in millimeters. 1 UH-PRC002-EN 2 3 47 Dimensions and Weights Table 22. Tubular Heat Exchanger unit heater dimensional data—model GTND/GTPD Model 030 035 040 Input MBh 300.0 A B C D E F G H L Diameter Flue Fan Gas Inlet Nat. LP Weight Unit Shipping in. mm 34 864 50-3/4 28-3/8 12-1/4 48-5/8 48-3/4 1289 721 311 1235 1238 5-1/8 130 24-1/2 55-1/4 622 1403 6 152 (2) 16 3/4 1/2 or 3/4 lb kg 307 139 367 166 in. mm 34 864 50-3/4 28-3/8 12-1/4 48-5/8 48-3/4 1289 721 311 1235 1238 5-1/8 130 24-1/2 55-1/4 622 1403 6 152 (2) 18 3/4 1/2 or 3/4 lb kg 321 145 381 173 in. mm 34 864 50-3/4 28-3/8 12-1/4 48-5/8 48-3/4 1289 721 311 1235 1238 5-1/8 130 24-1/2 55-1/4 622 1403 6 152 (2) 18 3/4 1/2 or 3/4 lb kg 335 152 395 179 350.0 400.0 1. Rear view 2. Side view 3. Front view 1 Dimensions are in inches. Dimensions in ( ) are in millimeters. 2 48 3 UH-PRC002-EN Dimensions and Weights Table 23. High-efficiency propeller fan gas unit heater dimensional data—model GHND/GHPD Unit Sizes 100 “A” Height to Top of Unit in. 31.25 mm 794 “B” Width of Unit in. 17.875 mm 454 “C” Height to Top of Hanger in. 34.125 mm 867 “D” Depth to Rear of Housing in. 37.5 mm 953 “E” Hanging Distance Width in. 14.5 mm 368 “F” Discharge Opening Width in. 15.375 mm 391 “G” Depth to Unit Side Jacket in. 26.75 mm 679 “H” Discharge Opening Height in. 18 mm 457 “J” to Centerline of Flue in. 5.872 mm 149 “K” Depth to Centerline of Flue in. 30.625 mm 778 “L” Hanger Location in. 16.25 mm 413 Flue Size Diameter(a) in. 4 mm 102 Fan Diameter in. 14 Gas Inlet-Natural Gas in. 0.5 Gas Inlet-LP Gas in. 0.5 Approximate Shipping Weight lb 174 kg 79 125 150 175 200 225 250 300 350 400 31.25 794 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 20.625 524 20.625 524 23.375 594 26.125 664 28.875 733 31.625 803 37.125 943 42.625 1083 48.125 1222 34.125 867 39.125 994 39.125 994 39.125 994 39.125 994 39.125 994 39.125 994 39.125 994 39.125 994 37.5 953 37.5 953 37.5 953 37.5 953 37.5 953 37.5 953 37.5 953 37.5 953 37.5 953 17.25 438 17.25 438 20 508 22.75 578 25.5 648 28.25 718 33.75 857 39.25 997 44.75 1137 18.125 460 18.125 460 20.875 530 23.625 600 26.375 670 29.125 740 34.625 879 40.125 1019 45.625 1159 26.75 679 26.75 679 26.75 679 26.75 679 26.75 679 26.75 679 26.75 679 26.75 679 26.75 679 18 457 18 457 18 457 18 457 18 457 18 457 18 457 18 457 18 457 7.25 184 7.25 184 8.625 219 10 254 11.25 286 12.75 324 15.5 394 18.25 464 21 533 30.625 778 30.625 778 30.625 778 30.625 778 30.625 778 30.625 778 30.625 778 30.625 778 30.625 778 16.75 425 16.375 416 16.375 416 16.375 416 16.75 425 16.75 425 16.75 425 16.75 425 16.75 425 4 102 4 102 4 102 5 127 5 127 5 127 6 152 6 152 6 152 16 16 18 18 18 18 (2) 16 (2) 18 (2) 18c 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.5 0.5 0.5 0.5 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 197 89 219 99 238 108 249 113 275 125 305 138 350 159 414 188 461 209 (a) The flue opening on all “GH” units is 5-1/8” diameter. Therefore, a transition adapter is required by installer on these units. 1. Side view, sizes 100–200 2. Side view, sizes 225–400 3. Front view, sizes 30–400 *Canadian units include vent cap and reducer/increaser (if required). 1 UH-PRC002-EN 2 3 Dimensions in ( ) are in millimeters. 49 Dimensions and Weights Table 24. High-efficiency centrifugal fan unit heater dimensional data—model GBND/GBPD Unit Sizes 100 “A” Height to Top of Unit in. 31.25 mm 794 “B” Width of Unit in. 17.875 mm 454 “C” Height to Top of Hanger in. 34.125 mm 867 “D” Depth to Rear of Housing in. 42.625 mm 1083 “E” Hanging Distance Width in. 14.5 mm 368 “F” Discharge Opening Width in. 15.375 mm 391 “J” to Centerline of Flue in. 5.875 mm 149 “L” Hanger Location in. 16.375 mm 416 “M” Hanging Distance Depth in. 16.375 mm 416 Flue Size Diameter(a) in. 4 mm 102 Blower Size in. 9 Gas Inlet-Natural Gas in. 0.5 Gas Inlet-LP Gas in. 0.5 Approximate Shipping Weight lb 262 kg 119 125 150 175 200 225 250 300 350 400 31.25 794 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 20.625 524 20.625 524 23.375 594 26.125 664 28.875 733 31.625 803 37.125 943 42.625 1083 48.125 1222 34.125 867 39.125 994 39.125 994 39.125 994 39.125 994 39.125 994 39.125 994 39.125 994 39.125 994 44.25 1124 44.25 1124 47 1194 47 1194 51 1295 51 1295 48.25 1226 51 1295 51 1295 17.25 438 17.25 438 20 508 22.75 578 25.5 648 28.25 718 33.75 857 39.25 997 44.75 1137 18.125 460 18.125 460 20.875 530 23.625 600 26.375 670 29.125 740 34.625 879 40.125 1019 45.625 1159 7.25 184 7.25 184 8.625 219 10 254 11.25 286 12.75 324 15.5 394 18.25 464 21 533 16.375 416 16.375 416 16.375 416 16.375 416 16.375 416 16.375 416 16.375 416 16.375 416 16.375 416 16.375 416 16.375 416 17.875 454 17.875 454 21.875 556 21.875 556 21.875 556 21.875 556 21.875 556 4 102 4 102 4 102 5 127 5 127 5 127 6 152 6 152 6 152 10 10 12 12 12 12 (2) 10 (2) 12 (2) 12 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.5 0.5 0.5 0.5 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 279 127 314 142 336 152 363 165 408 185 427 194 471 214 561 254 594 269 (a) The flue opening on all “GB” units is 5-1/8” diameter. Therefore, a transition adapter is required by installer on these units. 1. Side view, sizes 100–200 2. Side view, sizes 225–400 3. Front view, sizes 100–400 1 2 3 *Canadian units include vent cap and reducer/increaser (if required). Dimensions in ( ) are in millimeters. 50 UH-PRC002-EN Dimensions and Weights Table 25. Separated combustion propeller fan gas unit heater dimensional data—model GAND/GAPD Unit Sizes 100 “A” Height to Top of Unit in. 31.25 mm 794 “B” Height to Top of Hanger in. 34.062 mm 865 “C” Hanging Distance Width in. 14.75 mm 375 “D” Discharge Opening Width in. 15.375 mm 391 “E” Width of Unit in. 17.875 mm 454 “F” to Centerline of Flue in. 5.875 mm 149 Flue Size Diameter(a) in. 4 mm 102 Fan Diameter in. 14 Gas Inlet-Natural Gas in. 0.5 Gas Inlet-LP Gas in. 0.5 Approximate Shipping Weight lb 200 kg 91 125 150 175 200 225 250 300 350 400 31.25 794 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 34.062 865 39.062 992 39.062 992 39.062 992 39.062 992 39.062 992 39.062 992 39.062 992 39.062 992 17.5 445 17.5 445 20.25 514 23 584 25.75 654 28.5 724 34 864 39.5 1003 45 1143 18.125 460 18.125 460 20.875 530 23.625 600 26.375 670 29.125 740 34.625 879 40.125 1019 45.625 1159 20.625 524 20.625 524 23.375 594 26.125 664 28.875 733 31.625 803 37.125 943 42.625 1083 48.125 1222 7.25 184 7.25 184 8.625 219 10 254 11.25 286 12.75 324 15.5 394 18.25 464 21 533 4 102 4 102 4 102 5 127 5 127 5 127 6 152 6 152 6 152 16 16 18 18 18 18 (2) 16 (2) 18 (2) 18 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.5 0.5 0.5 0.5 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 228 103 256 116 284 129 312 142 340 154 368 167 432 196 488 221 545 247 (a) The flue opening on all units is 5-1/8” diameter. Therefore, a transition adapter is required by installer on these units. 1. Front view, sizes 100–400 2. Side view, sizes 100–200 3. Side view, sizes 225–400 1 2 3 Note: Air intake is round on 225/ 250 units. For 300/400 units, air intake is as shown. *Canadian units include vent cap and reducer/increaser (if required). Dimensions in ( ) are in millimeters. UH-PRC002-EN 51 Dimensions and Weights Table 26. Separated combustion centrifugal fan unit heater dimensional data—model GKND/GKPD Unit Sizes 100 “A” Height to Top of Unit in. 31.25 mm 794 “B” Height to Top of Hanger in. 34.062 mm 865 “C” Hanging Distance Width in. 14.75 mm 375 “D” Discharge Opening Width in. 15.375 mm 391 “E” Width of Unit in. 17.875 mm 454 “F” to Centerline of Flue in. 5.875 mm 149 “G” Hanging Distance Depth in. 18.5 mm 470 “H” Depth to Rear of Housing in. 42.75 mm 1086 (a) Flue Size Diameter in. 4 mm 102 Blower Size in. 9 Gas Inlet-Natural Gas in. 0.5 Gas Inlet-LP Gas in. 0.5 Approximate Shipping Weight lb 298 kg 135 125 150 175 200 225 250 300 350 400 31.25 794 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 36.25 921 34.062 865 39.062 992 39.062 992 39.062 992 39.062 992 39.062 992 39.062 992 39.062 992 39.062 992 17.5 445 17.5 445 20.25 514 23 584 25.75 654 28.5 724 34 864 39.5 1003 45 1143 18.125 460 18.125 460 20.875 530 23.625 600 26.375 670 29.125 740 34.625 879 40.125 1019 45.625 1159 20.625 524 20.625 524 23.375 594 26.125 664 28.875 733 31.625 803 37.125 943 42.625 1083 48.125 1222 7.25 184 7.25 184 8.625 219 10 254 11.25 286 12.75 324 15.5 394 18.25 464 21 533 18.5 470 18.5 470 20 508 20 508 23 584 23 584 23 584 23 584 23 584 44.375 1127 44.375 1127 47.187 1199 47.187 1199 50.875 1292 48 1219 50.875 1292 50.875 1292 51 1295 4 102 4 102 4 102 5 127 5 127 5 127 6 152 6 152 6 152 10 10 12 12 12 12 (2) 10 (2) 12 (2) 12 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.5 0.5 0.5 0.5 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 330 150 362 164 394 179 426 193 458 208 490 222 558 253 618 280 678 308 (a) The flue opening on all units is 5-1/8” diameter. Therefore, a transition adapter is required by installer on these units. 1. Front view, sizes 100–400 2. Side view, sizes 100–200 3. Side view, sizes 225–400 1 2 3 Note: Air intake is round on 225/ 250 units. For 300/400 units, air intake is as shown. *Canadian units include vent cap and reducer/increaser (if required). Dimensions in ( ) are in millimeters. 52 UH-PRC002-EN Dimensions and Weights Table 27. High-efficiency duct furnaces—model GLND/GLPD Model 010 012 015 017 020 022 025 030 035 040 Input MBh 100 Gas Inlet Nat. LP A B C D (Dia.) F in. mm 17.875 454 15.5 394 17.125 435 4 102 23.875 606 1/2 1/2 lb kg 173 78 in. mm 20.625 524 18.25 464 19.875 505 4 102 25.625 651 1/2 1/2 lb kg 186 84 in. mm 20.625 524 18.25 464 19.875 505 4 102 26.625 676 1/2 1/2 lb kg 197 89 in. mm 23.375 594 21 533 22.625 575 4 102 29.375 746 1/2 1/2 lb kg 216 98 in. mm 26.125 664 23.75 603 25.375 645 5 127 32.125 816 1/2 1/2 lb kg 232 105 28.875 733 26.5 673 28.125 714 5 127 34.875 886 3/4 1/2 or 3/4 lb kg 254 115 in. mm 31.625 803 29.25 743 30.875 784 5 127 37.625 956 3/4 1/2 or 3/4 lb kg 263 119 in. mm 37.125 943 34.75 883 36.375 924 6 152 43.125 1095 3/4 1/2 or 3/4 lb kg 312 142 in. mm 42.625 1083 40.25 1022 41.875 1064 6 152 48.625 1235 3/4 1/2 or 3/4 lb kg 389 176 in. mm 48.125 1222 45.75 1162 47.375 1203 6 152 54.125 1375 3/4 1/2 or 3/4 lb kg 403 183 Weight 125 150 175 200 225 250 300 350 400 1. Side view, sizes 100–125 2. Front view, sizes 100–400 3. Side view, sizes 150–400 4. Side view, sizes 100–125 5. Front view, sizes 100–400 6. Side view, sizes 150–400 7. 1 4 UH-PRC002-EN 2 5 Detail G positions: front, rear, right, left 3 6 *Canadian units include vent cap and reducer/ increaser (if required). Rear vent position shown. See Detail G for optional top vent position. Dimensions are in inches. Dimensions in ( ) are in millimeters. 7 53 Dimensions and Weights Table 28. Separated combustion indoor gas duct furnaces—model GMND/GMPD Model 010 012 015 017 020 022 025 030 035 040 Input MBh 100 A B Gas Inlet D (Dia.)(a) Nat. LP C Weight in. mm 17-7/8 15-1/2 17-1/8 454 394 435 4 102 1/2 1/2 lb kg 161 73 in. mm 20-5/8 18-1/4 19-7/8 524 464 505 4 102 1/2 1/2 lb kg 180 82 in. mm 20-5/8 18-1/4 19-7/8 524 464 505 4 102 1/2 1/2 lb kg 188 85 in. mm 23-3/8 594 22-5/8 575 4 102 1/2 1/2 lb kg 207 94 in. mm 26-1/8 23-3/4 25-3/8 664 603 645 5 127 1/2 1/2 lb kg 227 103 28-7/8 26-1/2 28-1/8 733 673 714 5 127 3/4 1/2 or 3/4 lb kg 246 112 in. mm 31-5/8 29-1/4 30-7/8 803 743 784 5 127 3/4 1/2 or 3/4 lb kg 266 121 in. mm 37-1/8 34-3/4 36-3/8 943 883 924 6 152 3/4 1/2 or 3/4 lb kg 305 138 in. mm 42-5/8 40-1/4 41-7/8 1083 1022 1064 6 152 3/4 1/2 or 3/4 lb kg 344 156 in. mm 48-1/8 45-3/4 47-3/8 1222 1162 1203 6 152 3/4 1/2 or 3/4 lb kg 383 174 125 150 175 21 533 200 225 250 300 350 400 (a) “D” diameter equals the air inlet opening and the flue discharge opening. 1. Sizes 100–250 2. Sizes 300–400 †Oval connector shown accepts 6” Dia. (152) pipe. *Canadian units include vent cap and reducer/increaser (if required). Rear vent position shown. See Detail G for optional top vent position. Dimensions are in inches. Dimensions in ( ) are in millimeters. 1 54 2 3 UH-PRC002-EN Dimensions and Weights Table 29. Horizontal blower assembly dimension data Model HBAC-15 Nominal cfm 1500 Input MBh(a) 100 Filter Size** # Req. Ship Weight(b) A B C D E F G in. mm 65-1/2 1664 26 660 10 254 18 457 21-1/4 540 15-3/4 400 15-5/8 397 25 x 25 x 1 1 lb kg 135 61 in. mm 65-1/2 1664 26 660 10 254 18 457 21-1/4 540 15-3/4 400 18-3/8 467 25 x 25 x 1 1 lb kg 135 61 in. mm 65-1/2 1664 26 660 10 254 18 457 21-1/4 540 15-3/4 400 18-3/8 467 25 x 25 x 1 1 lb kg 155 70 in. mm 65-1/2 1664 26 660 10 254 18 457 21-1/4 540 15-3/4 400 21-1/8 537 25 x 25 x 1 1 lb kg 155 70 in. mm 65-1/2 1664 40-1/2 1029 10 254 18 457 35-3/4 908 30-3/8 772 23-7/8 606 25 x 20 x 1 2 lb kg 200 91 in. mm 65-1/2 1664 40-1/2 1029 10 254 18 457 35-3/4 908 30-3/8 772 26-5/8 676 25 x 20 x 1 2 lb kg 200 91 in. mm 65-1/2 1664 40-1/2 1029 10 254 18 457 35-3/4 908 30-3/8 772 29-3/8 746 25 x 20 x 1 2 lb kg 200 91 in. mm 65-1/2 1664 60-1/2 1537 10 254 18 457 55-3/4 1416 50-3/8 1280 34-7/8 886 25 x 20 x 1 3 lb kg 296 134 in. mm 69-1/2 1765 60-1/2 1537 14 356 22 559 55-3/4 1416 50-3/8 1280 40-3/8 1026 25 x 20 x 1 3 lb kg 296 134 in. mm 69-1/2 1765 60-1/2 1537 14 356 22 559 55-3/4 1416 50-3/8 1280 45-7/8 1165 25 x 20 x 1 3 lb kg 296 134 125 HBAC-20 2000 150 175 HBAC-30 3000 200 225 250 HBAC-45 4500 300 350 400 Notes: 1. Nominal 4,500 cfm unit has two blowers driven by one motor. 2. Transition designed for specific duct furnace referenced in the table above. Variations from standard will require field-supplied transitions. (a) Size of duct furnace used with horizontal blower assembly. (b) Ship weight is approximate and does not include motor. Dimensions are in inches. Dimensions in ( ) are in millimeters. UH-PRC002-EN 55 Dimensions and Weights Table 30. Factory-installed flue vent data (standard on high-efficiency units) Unit Size Input MBh 30 45 60 75 100 125 150 175 200 225 250 300 350 400 5-1/8 5-1/8 5-1/8 5-1/8 5R 6R 6R 6R 50 50 50 50 Flue Outlet in. 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 Recommended Flue Size in. 4R 4R 4R 4R 4R 4R 4R 4R 5R 5R Maximum Length of Run(a) ft 50 50 50 50 50 50 50 50 50 50 Notes: 1. Horizontal vent pipes should be pitched downward 1/4-inch per foot toward the outlet for condensate drainage. 2. Motors are 1/20 hp. All fans are 115 V and draw 1.5 amps. (a) Vent pipe equivalent length must not exceed 50 feet. Equivalent length is the total length of straight sections, plus 15 feet for each 90° elbow and 8 feet for each 45° elbow. Table 31. Factory-installed flue vent data (standard on separated combustion units) Unit Size Input MBh 30 45 60 75 100 125 150 175 200 225 250 300 350 400 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 4R 4R 4R 5R 5R 5R 6R 6R 6R 50 50 50 50 50 50 50 50 50 4R 4R 4R 5R 5R 5R 6 OV 6 OV 6 OV 50 50 50 50 50 50 50 50 50 Flue Flue Outlet in. 5-1/8 5-1/8 5-1/8 5-1/8 5-1/8 Recommended Flue Size in. 4R 4R 4R 4R 4R Maximum Length of Run(a) ft 50 50 50 50 50 Combustion Air Combustion Air Inlet in. 4R 4R 4R 4R 4R Maximum Length of Run(a) ft 50 50 50 50 50 Notes: 1. Horizontal vent pipes should be pitched downward 1/4-inch per foot toward 2. Motors are 1/20 hp. All fans are 115 V and draw 1.5 amps. the outlet for condensate drainage. (a) Flue outlet or combustion air inlet pipe equivalent length must not less than 5 feet and must not exceed 50 feet. Equivalent length is the total length of straight sections, plus 15 feet for each 90° elbow and 8 feet for each 45° elbow. 56 UH-PRC002-EN Dimensions and Weights 1 2 3 4 1. 30° nozzle 2. 60° nozzle 3. 90° nozzle Note: 30°, 60°, and 90° nozzles are shipped unassembled with bagged hardware and field assembling and installation instruction sheet. The six (6) louvers and louver springs are removed from the unit heaters and transferred to the nozzles in the field. 4. Y-splitter Table 32. Nozzle dimensional data Unit MBh A 100 125 150 175 200 225 250 300 350 400 in. mm 17.44 445 20.19 513 20.19 513 22.94 583 25.69 653 28.44 722 31.19 792 36.69 932 42.19 1072 47.69 1211 in. mm 15.368 391 18.118 460 18.118 460 20.868 530 23.618 600 26.368 670 29.118 740 34.618 879 40.118 1019 45.618 1159 B Table 33. Y-splitter dimensional data Unit MBh Width 100 125 150 175 200 225 250 300 350 400 in. mm 15-3/8 391 18-1/8 461 18-1/8 461 20-7/8 527 23-5/8 600 26-3/8 671 29-1/8 740 34-5/8 880 40-1/8 1019 45-5/8 1159 in. mm 21-1/8 537 21-1/8 537 21-1/8 537 21-1/8 537 21-1/8 537 21-1/8 537 21-1/8 537 21-1/8 537 21-1/8 537 21-1/8 537 in. mm 11 279 11 279 11 279 11 279 11 279 13-1/8 334 13-1/8 334 15-1/8 384 20-5/8 524 20-5/8 524 Height Depth UH-PRC002-EN 57 Mechanical Specifications Tubular Heat Exchanger Indoor Gas Unit (model GT) Unit is completely factory assembled, piped, wired and test fired. Unit is AGA and CGA certified, over 80 percent thermal (combustion) efficient. These propeller type units are provided with aluminized tubular heat exchanger, in-shot burner, hot surface pilot ignition, individually adjustable and removable louvers, 100 percent baked enamel finish, 115/60/1 supply voltage, removable access door on size 30 to 120 MBh, and hinged access control panel on 150 to 400 MBh, power vented, single-stage combination gas valve, two-stage available on 150 to 400 MBh, 24V control transformer and 115/60/1 volt fan motor with internal overload protection. The size 30 to 120 MBh are available in low profile design. OSHA fan guard is standard on all units size 30 to 120 MBh. Units sized 150 to 400 MBh are shipped with a non-OSHA type guard; the OSHA guard is available as a selectable option. Tubular Heat Exchanger Heat exchanger construction consists of 20-gauge aluminized steel. The tubular design provides maximum and uniform heat transfer. The low pressure drop enables heated air to be evenly distributed. The curved, non-welded serpentine design, experiences less thermally induced stress making it highly durable for longer service life. Cabinet The cabinet is constructed of 20-gauge cold rolled steel. All components are individually electrostatically painted. Hot Surface Pilot Ignition This ignition is constructed of shock resistant ceramic composite hot surface element. This system does not permit pilot gas to flow unless the hot surface element is present and powered. The low voltage hot surface element lights the pilot quickly for fast heat delivery. All wiring is 24V with no line voltage in the burner area. Venting The tubular design is AGA/CGA certified in accordance with Categories I and III venting requirements. Category I enables units to be vented vertically with either single or double wall venting material. Category III allows for horizontal venting utilizing single wall venting material. This venting flexibility makes installation easier and more cost effective. Control Accessibility All controls are easily accessible with ignition and fan controls located in one centrally located control panel. The removable door on size 30 to 75 MBh and the hinged access door on the 100 to 400 MBh provide control isolation. Motor –115V ODP Motor is 115V, 60 Hz, single phase, open drip-proof with built-in thermal overload protection. Optional Feature Motor — 115V totally enclosed. Motor is 115V, 60 Hz, single phase, totally enclosed with built-in thermal overload protection. Warranty The heat exchanger, flue collector and burners are covered by a 10-year warranty from the date of manufacture. 58 UH-PRC002-EN Mechanical Specifications High Efficiency Propeller (model GH) and Centrifugal Fan Gas Unit Heaters (model GB) General Units are completely factory assembled, piped, wired, and test fired. All units are AGA Certified and conform with the latest ANSI Standards for safe and efficient performance. Units are provided with two-point suspension hangers on propeller fan unit heaters and with four-point suspension hangers on centrifugal fan unit heaters. All units are available for operation on either natural or LP (liquid propane) gas. Casing Casings are die-formed, 20-gauge galvanized steel and finished in baked enamel. The bottom panel is easily removed to provide service access to the burners, pilot and orifices. The pilot is also accessible through a side panel access plate. All units are provided with independently adjustable horizontal louvers with stops to prevent total closure. Heat Exchanger Standard heat exchanger construction consists of seam welded 20-gauge aluminized steel tubes and 18-gauge aluminized steel headers. The heat exchanger, burner, and draft hood assembly carry a non-prorated warranty to be free from defective material and workmanship for a period of ten years from date of manufacture, excluding loss due to misuse, negligence, or corrosion by chemicals precipitated in the air. Burners Burners are die-formed, corrosion resistant aluminized steel, with stainless steel port protectors. Port protectors reduce scale or foreign matter from obstructing the burner ports. Burners are individually removable for ease of inspection and servicing. Each burner is provided with an individually adjustable, manually rotated air shutter adjustment. Fans Fan blades are constructed of aluminum with an aerodynamic contour. All fans are dynamically balanced for quiet, efficient operation and supplied with a protective type fan guard. Rubber-inshear isolators provide isolation between the fan/motor combination and the unit heater casing. All Motors Standard motors are 115V, 60 Hz, single phase, open drip-proof with built-in thermal overload protection. Optional Fan Unit Motors All motors are 115V, 60 Hz, single-phase totally enclosed with built-in thermal overload protection and permanently lubricated bearings. Controls A factory installed junction box is provided for all power connections. Standard units are provided with a 24V combination single stage redundant gas valve, consisting of a combination pilot solenoid valve, automatic electric gas valve, pilot filter, pressure regulator, pilot adjustment and manual shutoff. A flue vent fan relay and combustion air proving switch is also provided as standard. Standard equipment includes spark-ignited intermittent pilot system with electronic flame supervision. A 24V control transformer, high limit and fan time delay relay are provided. The fan time delay relay delays the fan start until the heat exchanger reaches a predetermined temperature. It also allows the fan to operate after burner shutdown, removing residual heat from the heat exchanger. UH-PRC002-EN 59 Mechanical Specifications Two-Stage Gas Valve Provides two stages of heat. Ignition is at low fire (50 percent of the furnace’s rated input). Requires the use of a two-stage thermostat. Electronic Modulating Gas Valve (Natural Gas Units Only) Provides modulated heat output. Ignition is at full fire (100 percent input), and modulates the gas input from 100 percent to 50 percent rated input. Available for use with room thermostat or duct thermostat with remote setpoint adjustment. Duct thermostat available with optional override room thermostat which causes the unit to go to full fire when the room temperature falls below the override room thermostat. Electronic Modulating, 4–20 mA/0–10 Vdc Input Provides modulated heat output. Ignition is at full fire (100 percent input), and modulates the gas input from 100 percent to 40 percent rated input. The modulating gas valve shall operate in response to a 4–20 mA or a 0–10 Vdc input from an external DDC control. Flue Vent Fan Flue vent fan provides power venting. Provided factory assembled to a sealed flue collection chamber. The flue vent fan is activated in response to a low voltage (24V) single-stage thermostat. Note: Thermostat must be ordered. A combustion air pressure switch is provided as standard to verify proper powered vent flow prior to allowing the gas valve to operate. Factory-Installed Options Heat Exchanger Options Type 409 Stainless Steel Heat exchanger tubes and headers are seam welded 20-gauge Type 409 stainless steel. Type 321 Stainless Steel Heat exchanger tubes and headers are seam welded 20-gauge Type 321 stainless steel. (Not available on 30, 45, 60 and 75 MBh units.) Additional Options Type 409 Stainless Steel Burners Type 409 Stainless Steel Draft Diverter Orifices for elevations over 2,000 feet Summer/Winter Switch Vertical Louvers Duct Discharge Flange (Centrifugal fan units only) Provided in lieu of louvers on units for use with field ductwork. OSHA Fan Guards—All Propeller Units OSHA fan guards are available as a factory-installed or field-installed option. Field-Installed Accessories High Gas Line Pressure Regulator (Natural gas units only) Reduces main gas line pressure to a minimum of seven inches wc (water column). Pressure at the jobsite must be specified. The regulator is selected to accommodate that specific pressure. 60 UH-PRC002-EN Mechanical Specifications Thermostats Low voltage room thermostat, single-stage. Low voltage room thermostat, single-stage with summer/winter switch. Low voltage duct thermostat, single-stage. Universal tamper-proof guard for all room thermostats. Low voltage room thermostat, two-stage. Low voltage duct thermostat, two-stage. Room thermostat, electronic modulating control. Duct thermostat, electronic modulating control. Override room thermostat, for use with duct thermostat and electronic modulating control. Discharge Nozzles Y Splitter 30° Downward 60° Downward 90° Downward Separated Combustion Centrifugal (model GK) and Propeller Fan Gas Unit Heaters (model GA) General Units are completely factory assembled, piped, wired, and test fired. All units are AGA Certified, 80 percent efficient and conform with the latest ANSI Standards for safe and efficient performance. Units are provided with two-point suspension hangers on propeller fan unit heaters and with fourpoint suspension hangers on centrifugal fan unit heaters. Units are available for operation on either natural or LP (propane) gas. Standard terms and conditions apply. Casing Casings are die-formed, 20-gauge galvanized steel and finished in baked enamel. The bottom panel is easily removed to provide service access to the burners, pilot and orifice. All units provided with independently adjustable horizontal louvers with stops to prevent total closure. Heat Exchanger Standard heat exchanger construction consists of seam welded 20-gauge aluminized steel tubes and 18-gauge aluminized steel headers. Burners Burners are die-formed, corrosion resistant aluminized steel, with stainless steel port protectors. Port protectors prevent scale or foreign matter from obstructing the burner ports. Burners individually removable for ease of inspection and servicing. Each burner is provided with an individually adjustable, manually rotated air shutter adjustment. Fans Propeller fan blades are constructed of aluminum with an aerodynamic contour. All fans are dynamically balanced for quiet, efficient operation and supplied with a protective type fan guard. Rubber-in-shear isolators provide isolation between the fan/motor combination and the unit heater casing. Centrifugal fan is belt driven with adjustable pitch motor sheave. Motor and fan are dynamically balanced for quiet operation. UH-PRC002-EN 61 Mechanical Specifications Centrifugal Unit Motors Standard motors are 115V, 60 Hz, single phase, open drip-proof with built-in thermal overload protection. Optional 230/60/1 motors are available on all units. Optional 208, 230, 460/60/3 motors are available on 125 through 400 MBh units. All Motors All motors are 115V, 60 Hz, single-phase open drip-proof with built-in thermal overload protection and permanently lubricated bearings. Controls A factory installed junction box is provided for all power connections. Standard units are provided with a 24V combination single-stage redundant gas valve, consisting of a combination pilot solenoid valve, automatic electric gas valve, pilot filter, pressure regulator, pilot adjustment and manual shutoff. A flue vent fan relay and combustion air proving switch is also provided as standard. Standard equipment includes spark-ignited intermittent pilot system with electronic flame supervision. A 24V control transformer, high limit and fan time delay relay are provided. The fan time delay relay delays the fan start until the heat exchanger reaches a predetermined temperature. It also allows the fan to operate after burner shutdown, removing residual heat from the heat exchanger. Electronic Modulating, 4–20 mA/0–10Vdc Input Provides modulated heat output. Ignition is at full fire (100 percent input), and modulates the gas input from 100 percent to 40 percent rated input. The modulating gas valve shall operate in response to a 4–20 mA or a 0–10 Vdc input from an external DDC control. Flue Vent Fan Flue vent fan provides power venting. Provided factory assembled to a sealed flue collection chamber. The flue vent fan is activated in response to a low voltage (24V) single-stage thermostat. Note: The thermostat is not included with the gas control option). A combustion air pressure switch is provided as standard to verify proper powered vent flow prior to allowing the gas valve to operate. Factory-Installed Options Two-Stage Gas Valve Provides two stages of heat. Ignition is at low fire (50 percent of the furnaces rated input). Requires the use of a two-stage thermostat. Heat Exchanger Options Type 409 Stainless Steel Heat exchanger tubes and headers are seam welded 20-gauge Type 409 stainless steel. Type 321 Stainless Steel Heat exchanger tubes and headers are seam welded 20-gauge Type 321 stainless steel. Additional Options Type 409 Stainless Steel Burners Type 409 Stainless Steel Draft Diverter Totally Enclosed Motor Orifices for elevations over 2000 feet 62 UH-PRC002-EN Mechanical Specifications Summer/Winter Switch Vertical Louvers Duct Discharge Flange (Centrifugal fan units only) Provided in lieu of louvers on units for use with field ductwork. OSHA Fan Guards OSHA fan guards are available as a factory installed or field installed option. Field-Installed Accessories LP (Propane) to Natural Gas Conversion Package High Gas Line Pressure Regulator (Natural gas units only) Reduces main gas line pressure to a minimum of seven-inches wc (water column). Pressure at the jobsite must be specified. The regulator is selected to accommodate that specific pressure. Thermostats Low voltage room thermostat, single-stage. Low voltage room thermostat, single-stage with summer/winter switch. Low voltage duct thermostat, single-stage. Low voltage room thermostat, two-stage. Low voltage duct thermostat, two-stage. Universal tamperproof guard for all room thermostats. Discharge Nozzles Y Splitter 30° Downward 60° Downward 90° Downward Concentric Vent Terminals Vertical Concentric Vent Kit Kit includes 5” cap with special attached non-recirculation disc, special 8” cap with 5” hole and concentric vent box. Horizontal Concentric Vent Kit Kit includes 5” cap with special attached non-recirculation disc, inlet air screen and concentric vent box. High Efficiency Indoor Gas Duct Furnaces (model GL) General Units are completely factory assembled, piped, wired, and test fired. All units are AGA Certified and conform with the latest ANSI Standards for safe and efficient performance. Units are provided with four point suspension hangers, and are available for operation on either natural or LP (propane) gas. Casing Casings are die-formed, 20-gauge galvanized steel and finished in baked enamel. The bottom panel is easily removed to provide access to the burners, pilot, and orifices. The pilot is also accessible UH-PRC002-EN 63 Mechanical Specifications through a side panel access plate. The high limit switch is accessible through a side panel access. Duct discharge flanges for simple ductwork connection are provided. Heat Exchanger Standard heat exchanger construction consists of seam welded 20-gauge aluminized steel tubes and 18-gauge aluminized steel headers. Burners Burners are die-formed, corrosion resistant aluminized steel, with stainless steel port protectors. Port protectors prevent foreign matter from obstructing the burner ports. Burners individually removable for ease of inspection and servicing. Each burner is provided with an individually adjustable, manually rotated air shutter adjustment. Air shutter adjustment is fixed when side access burner drawer is supplied. Controls A factory installed junction box is provided for all power connections. Standards units are provided with a 24-volt combination single-stage redundant gas valve, consisting of a combination pilot solenoid valve, automatic electric gas valve, pilot filter, pressure regulator, pilot adjustment and manual shutoff. A flue vent fan relay and combustion air proving switch is also provided as standard. Standard equipment includes spark-ignited intermittent pilot system with electronic flame supervision. A 24V control transformer and a high limit are provided. Flue Vent Fan Flue vent fan is factory assembled to a sealed flue collection chamber and provides power venting. The flue vent fan is activated in response to a low voltage (24V) single-stage thermostat. A combustion air pressure switch is provided as standard to verify proper powered vent flow prior to allowing the gas valve to operate. Control Options Two-Stage Gas Valve Provides two stages of heat. Ignition is at low fire (50 percent of the furnace’s rated input). Requires the use of a two-stage thermostat. (Thermostat not included.) Electronic Modulating Gas Valve (Natural Gas Units Only) Provides modulated heat output. Ignition is at full fire (100 percent input), and modulates the gas input from 100 percent to 50 percent rated input. Available for use with room thermostat or duct thermostat with remote setpoint adjustment. Duct thermostat available with optional override room thermostat which causes the unit to go to full fire when the room temperature falls below the override room thermostat. Electronic Modulating 4–20 mA/0–10 Vdc Input Provides modulated heat output. Ignition is at full fire (100 percent input), and modulates the gas input from 100 percent to 40 percent rated input. The modulating gas valve shall operate in response to a 4–20 mA or a 0–10 Vdc input from an external DDC control. Heat Exchanger Options Type 409 Stainless Steel Heat exchanger tubes and headers are seam welded 20-gauge Type 409 stainless steel Type 321 Stainless Steel Heat exchanger tubes and headers are seam welded 20-gauge Type 321 stainless steel 64 UH-PRC002-EN Mechanical Specifications Additional Options Type 409 Stainless Steel Burners Orifices for Elevations over 2000 feet Type 409 Stainless Steel Draft Diverter Summer/Winter Switch Horizontal Louvers Horizontal and Vertical Louvers Side Access Burner Drawer Allows entire burner drawer to slide out from the side of the unit for service or inspection. Fan Time Delay Relay The fan time delay relay delays the fan start until the heat exchanger reaches a predetermined temperature. It also allows the fan to operate after burner shutdown, removing the residual heat from the heat exchanger. (Recommended on applications that require intermittent fan.) Field-Installed Accessories Natural to LP (Propane) Gas Conversion Package (Standing Pilot Only) LP (Propane) to Natural Gas Conversion Package High Gas Line Pressure Regulator—Reduces main gas line pressure to a minimum of 7 inches wc (water column). Pressure at the jobsite must be specified. The regulator is selected to accommodate that specific pressure. Discharge Nozzles “Y” Splitter 30° Downward 60° Downward 90° Downward Drain Pan Recommended for use with installations on the downstream side of a cooling coil. Thermostats Low voltage room thermostat, single-stage Low voltage room thermostat, two-stage Low voltage duct thermostat, single-stage Low voltage duct thermostat, two-stage Universal tamper-proof guard for all room thermostats Low voltage room thermostat, single-stage with summer/winter switch Room thermostat, electronic modulating control Duct thermostat, electronic modulating control Override room thermostat, for use with duct thermostat and electronic modulating control. Separated Combustion Duct Furnaces (model GM) General Units are completely factory assembled, piped, wired, and test fired. All units are AGA Certified, 80 percent efficient and conform with the latest ANSI Standards for safe and efficient performance. UH-PRC002-EN 65 Mechanical Specifications Units are provided with two-point suspension hangers on propeller fan unit heaters and with fourpoint suspension hangers on centrifugal fan unit heaters. Units are available for operation on either natural or LP (propane) gas. Standard terms and conditions apply. Casing Casings are die-formed, 20-gauge galvanized steel and finished in baked enamel. The bottom panel is easily removed to provide service access to the burners, pilot and orifice. All units provided with independently adjustable horizontal louvers with stops to prevent total closure. Heat Exchanger Standard heat exchanger construction consists of seam welded 20-gauge aluminized steel tubes and 18-gauge aluminized steel headers. Burners Burners are die-formed, corrosion resistant aluminized steel, with stainless steel port protectors. Port protectors prevent scale or foreign matter from obstructing the burner ports. Burners individually removable for ease of inspection and servicing. Each burner is provided with an individually adjustable, manually rotated air shutter adjustment. Controls A factory installed junction box is provided for all power connections. Standard units are provided with a 24V combination single-stage redundant gas valve, consisting of a combination pilot solenoid valve, automatic electric gas valve, pilot filter, pressure regulator, pilot adjustment and manual shutoff. A flue vent fan relay and combustion air proving switch is also provided as standard. Standard equipment includes spark-ignited intermittent pilot system with electronic flame supervision. A 24V control transformer, high limit and fan time delay relay are provided. The fan time delay relay delays the fan start until the heat exchanger reaches a predetermined temperature. It also allows the fan to operate after burner shutdown, removing residual heat from the heat exchanger. Electronic Modulating 4–20 mA/0–10 Vdc Input Provides modulated heat output. Ignition is at full fire (100 percent input), and modulates the gas input from 100 percent to 40 percent rated input. The modulating gas valve shall operate in response to a 4–20 mA or a 0–10 Vdc input from an external DDC control. Flue Vent Fan Flue vent fan provides power venting. Provided factory assembled to a sealed flue collection chamber. The flue vent fan is activated in response to a low voltage (24V) single-stage thermostat. Note: The thermostat is not included with the gas control option. A combustion air pressure switch is provided as standard to verify proper powered vent flow prior to allowing the gas valve to operate. Factory-Installed Options Two-Stage Gas Valve Provides two stages of heat. Ignition is at low fire (50 percent of the furnace’s rated input). Requires the use of a two-stage thermostat. Heat Exchanger Options Type 409 Stainless Steel Heat exchanger tubes and headers are seam welded 20-gauge Type 409 stainless steel. 66 UH-PRC002-EN Mechanical Specifications Type 321 Stainless Steel Heat exchanger tubes and headers are seam welded 20-gauge Type 321 stainless steel. Additional Options Type 409 Stainless Steel Burners Type 409 Stainless Steel Draft Diverter Totally Enclosed Motor (Centrifugal fan units only) Orifices for elevations over 2000 feet Summer/Winter Switch Vertical Louvers Duct Discharge Flange (Centrifugal fan units only) Provided in lieu of louvers on units for use with field ductwork. Field-Installed Accessories LP (Propane) to Natural Gas Conversion Package High Gas Line Pressure Regulator (Natural gas units only) Reduces main gas line pressure to a minimum of 7 inches wc (water column). Pressure at the jobsite must be specified. The regulator is selected to accommodate that specific pressure. Thermostats Low voltage room thermostat, single-stage. Low voltage room thermostat, single-stage with summer/winter switch. Low voltage duct thermostat, single-stage. Low voltage room thermostat, two-stage. Low voltage duct thermostat, two-stage. Universal tamperproof guard for all room thermostats. Discharge Nozzles Y Splitter 30° Downward 60° Downward 90° Downward Concentric Vent Terminals Vertical Concentric Vent Kit Kit includes 5” cap with special attached non-recirculation disc, special 8” cap with 5” hole and concentric vent box. Horizontal Concentric Vent Kit Kit includes 5” cap with special attached non-recirculation disc, inlet air screen and concentric vent box. Horizontal Blower Assembly (model HBAC) General Units are completely factory assembled, and have four-point suspension hangers and filter racks as standard. UH-PRC002-EN 67 Mechanical Specifications Casing Casings are 18-gauge galvanized steel with baked enamel finish. Side panels are removable for easy servicing and motor maintenance. Duct flanges are provided for simple ductwork connection. Standard filters are one-inch permanent washable type. Motors Factory-mounted motors are open drip-proof, 115, 230/60/1 or 208, 230, 460/60/3 with built-in thermal overload protection. Fans Centrifugal fan is belt driven with adjustable pitch motor sheave. Fan is dynamically balanced for quiet operation. Factory-Installed Options Insulation Blower assembly and transition are insulated with fire-resistant, odorless, matte-faced one-inch glass fiber material. Floor Mounting Legs Legs allow floor mounting of the blower assembly. Totally Enclosed Motor Field Installed Accessories Optional Filters (One-Inch Permanent Standard) One-inch throwaway One-inch permanent Transition When used with a duct furnace, a sheet metal transition is supplied to connect the blower assembly to the duct furnace. 68 UH-PRC002-EN www.trane.com For more information, contact your local Trane office or e-mail us at comfort@trane.com Literature Order Number UH-PRC002-EN Date September 2009 Supersedes UH-PRC002-EN July 2009 Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 69 Page Mode : UseOutlines XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:1c880ed3-aacc-4a2b-8354-edb190dfb25e Startup Profile : Print Producer : Acrobat Distiller 8.1.0 (Windows) Acces flag : F Alt order nbr : Alt order nbr type : Bw color : C Date published : 09/01/2009 Dept id : 144 Topic focused id : EN|TRANE Price : 0 Cur flag : T Lit class id : PL Lit length : 69 Lit order nbr : UH-PRC002-EN Lit type id : PRC Media id : PPI Model : GAND|GBND|GKND|GLND|GMND|GTND Prod class : TD|TD|TD|TD|TD|TD Prod family id : 70|70|70|70|70|70 Prod : UH|UH|UH|UH|UH|UH Restrct flag : F Source date : nulldate Source filename : Stocking loc id : LAXCPY Supceded by : Supceded by date : 07/01/2009 Unit flag : T Branding : Trane Lol language : EN Object id : 090102b181b84766 Object name : UH-PRC002-EN_09012009 Chronicle id : 090102b180081cbd Filename : 81b84766.pdf Keywords : GTND; GTPD; GHND; GHPD; GBND; GBPD; GAND; GAPD; GKND; GKPD; GLND; GLPD; GMND; GMPD; HBAC; gas; unit heater; duct furnace Abstract : Contains- features and benefits, model number description, general data, application considerations, selection procedure, performance adjustment factors, performance data, electrical data, jobsite connections, controls, typical wiring diagrams, dimensional data, venting unit heaters, features summarty, mechanical specifications. Hist model : GAND|GAND010**F|GAND012**G|GAND015**F|GAND017**G|GAND020**F|GAND022**G|GAND025**F|GAND030**F|GAND035**F|GAND040**F|GBND|GBND010**F|GBND012**F|GBND015**F|GBND017**F|GBND020**F|GBND022**F|GBND025**F|GBND030**F|GBND035**F|GBND040**F|GHND|GHND003**F|GHND004**F|GHND006**F|GHND007**F|GHND010**F|GHND012**F|GHND015**F|GHND017**G|GHND020**F|GHND022**G|GHND025**F|GHND030**F|GHND035**F|GHND040**F|GKND|GKND010**F|GKND012**F|GKND015**F|GKND017**F|GKND020**F|GKND022**F|GKND030**F|GKND035**F|GKND040**F|GLND|GLND010**F|GLND012**F|GLND015**F|GLND020**F|GLND022**F|GLND025**F|GLND030**F|GLND035**F|GLND040**F|GMND|GMND*****F|GMND010|GMND012|GMND015|GMND017|GMND020|GMND022|GMND025|GMND030|GMND035|GMND040|GTND|GTND003|GTND003**F|GTND004|GTND004**F|GTND006|GTND006**F|GTND007|GTND007**F|GTND009|GTND010|GTND010**F|GTND012|GTND012**F|GTND015|GTND015**F|GTND017|GTND017**F|GTND020|GTND020**F|GTND025|GTND025**F|GTND030|GTND030**F|GTND035|GTND035**F|GTND040|GTND040**F|GTNDR03**F|GTNDR04**F|GTNDR06**F|GTNDR07**F|GTNDR09**F Topic related id : TRN-HQ|TRN-FLD|RRR|OPER|IWD|DSGN|CONST|CONCPT|COMFRT Creator Tool : FrameMaker 8.0 Modify Date : 2009:09:22 12:08:04-05:00 Create Date : 2009:09:02 09:45:54Z Metadata Date : 2009:09:22 12:08:04-05:00 Document ID : uuid:c5bfdeb1-4d5d-4c26-9898-a3734088f2ea Instance ID : uuid:6db37695-2898-4100-bc9a-02bc46022905 N Pages : 69 Format : application/pdf Title : UH-PRC002-EN 09/01/2009 Product Catalog - Indoor Gas Heating Products - Unit Heaters, Duct Furnaces Creator : Gayle C. Edlin, Technical Writer - TCS Literature Description : Product Catalog - Indoor Gas Heating Products - Unit Heaters, Duct Furnaces Subject : GTND, GTPD, GHND, GHPD, GBND, GBPD, GAND, GAPD, GKND, GKPD, GLND, GLPD, GMND, GMPD, HBAC, gas, unit heater, duct furnace Rights : © 2009 Trane All rights reserved Author : Gayle C. Edlin Acces Flag : F Alt Order Nbr : Alt Order Nbr Type : Bw Color : C Hist Model : GAND|GAND010**F|GAND012**G|GAND015**F|GAND017**G|GAND020**F|GAND022**G|GAND025**F|GAND030**F|GAND035**F|GAND040**F|GBND|GBND010**F|GBND012**F|GBND015**F|GBND017**F|GBND020**F|GBND022**F|GBND025**F|GBND030**F|GBND035**F|GBND040**F|GHND|GHND003**F|GHND004**F|GHND006**F|GHND007**F|GHND010**F|GHND012**F|GHND015**F|GHND017**G|GHND020**F|GHND022**G|GHND025**F|GHND030**F|GHND035**F|GHND040**F|GKND|GKND010**F|GKND012**F|GKND015**F|GKND017**F|GKND020**F|GKND022**F|GKND030**F|GKND035**F|GKND040**F|GLND|GLND010**F|GLND012**F|GLND015**F|GLND020**F|GLND022**F|GLND025**F|GLND030**F|GLND035**F|GLND040**F|GMND|GMND*****F|GMND010|GMND012|GMND015|GMND017|GMND020|GMND022|GMND025|GMND030|GMND035|GMND040|GTND|GTND003|GTND003**F|GTND004|GTND004**F|GTND006|GTND006**F|GTND007|GTND007**F|GTND009|GTND010|GTND010**F|GTND012|GTND012**F|GTND015|GTND015**F|GTND017|GTND017**F|GTND020|GTND020**F|GTND025|GTND025**F|GTND030|GTND030**F|GTND035|GTND035**F|GTND040|GTND040**F|GTNDR03**F|GTNDR04**F|GTNDR06**F|GTNDR07**F|GTNDR09**F Date Published : 09/01/2009 Dept Id : 144 Topic Focused Id : EN|TRANE Cur Flag : T Lit Class Id : PL Lit Length : 69 Lit Order Nbr : UH-PRC002-EN Lit Type Id : PRC Media Id : PPI Prod Class : TD|TD|TD|TD|TD|TD Prod Family Id : 70|70|70|70|70|70 Topic Related Id : TRN-HQ|TRN-FLD|RRR|OPER|IWD|DSGN|CONST|CONCPT|COMFRT Restrct Flag : F Source Date : nulldate Source Filename : Stocking Loc Id : LAXCPY Supceded By : Supceded By Date : 07/01/2009 Unit Flag : T Lol Language : EN Object Id : 090102b181b84766 Object Name : UH-PRC002-EN_09012009 Chronicle Id : 090102b180081cbdEXIF Metadata provided by EXIF.tools