FAN-DS-2 August 2000 FAN-DS-2 Model Q™ Fans Sizes 16 through 60 Super Q II Fans Sizes 16 through 44 Model Q Fans Sizes 16 through 60 Super Q II Fans Sizes 16 through 44 Features and Benefits Q Fan • Flexible Installation Benefits ™ The Model Q fan is a quiet, airfoil, inline fan specifically designed for air conditioning applications. This highly refined axial flow fan is available in 13 sizes from 1,000 through 80,000 cfm. Small and compact, the Q fan has proven to be the ideal air moving device for standalone applications and also for custom air handling units. It can be used for supply, return and exhaust systems. Available in arrangement 1 (for floor mounting of larger units with heavier motors) and arrangement 9 (horizontal or vertical mounting), it can be selected in class 1, 2 and 3. Arrangement 9 permits factory mounting of the motor on top, bottom, or either side of the fan — see below. • The Q (Quiet) Fan The Trane Model Q fan generates less low frequency noise (more difficult to attenuate) than any other type of fan in the HVAC industry. Sound level comparisons show common vaneaxial fans produce up to 23 db higher sound levels than the Model Q — significant in industrial applications. Being quieter than centrifugal fans allows for installations closer to building occupants. The Model Q arrangement 9 can be set in any position, for horizontal discharge, angled discharge and vertical discharge either upblast or downflow. The only limitations placed on this arrangement are those dictated by good fan installation practice. • Motor slide rails and drive guard are standard, at no extra cost. • Saves Mechanical Room Space The compact quiet Q fan saves floor space, which reduces system first cost. • Easy To Install Rigging and installation is so much quicker and easier that total installed cost savings are typically five percent or more. • Low Maintenance Belt-driven with fixed blades, Model Q fan has very few moving parts. This design results in exceptionally low maintenance requirements. No fan teardowns need be scheduled. In fact, Q fans installed 25 years ago are still operating just as quietly as when they were installed. Discharge End View Arrangement 9 AMCA Licensed Ratings The Trane Company certifies that the Model Q fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. ©American Standard Inc. 2000 2 Arrangement 1 Contents Q Fan Accessories Features and Benefits • Inlet flange — for simplified, rigid connection of ductwork to inlet end of fan • Inlet screen — safety accessory mounted to fan inlet. Heavy, plated steel wire Note: inlet screen and inlet flange are mutually exclusive. • Inlet vanes — mechanically modulate fan capacity • Inlet bellmouth — used with unducted or plenum applications. Improves air flow and reduces noise. • Inlet silencer (long or short) — flex connected to Q fan • Outlet flange — for simplified, rigid connection of ductwork to outlet end of fan • Outlet screen — safety accessory mounted to fan outlet. Heavy, plated steel wire Note: outlet screen and outlet flange are mutually exclusive. • Outlet duct diffuser (equalizer) — makes fan outlet diameter equal to inlet diameter • Outlet flow stabilization screen — small mesh outlet screen. Helps offset effect of poor outlet airflow conditions • Outlet silencer (short or long) — flex connected to Q fan • Vertical mounting legs — used with arrangement 9 for vertical discharge floor and ceiling mounted • Isolators — to eliminate vibrations for floor, ceiling and vertical installations • Special coatings — to protect against alkyds, acids and corrosive environments • Access door — available on sizes 49, 54 and 60 for easier service • Drain — recommended to drain off the condensate where moisture-laden air is exhausted • Copper grease lines — plastic lines are standard • Double acoustic enhancement — insulation and perforated sheet metal to attenuate radiated sound • Fan insulation — self-adhesive foam, applied on the outside of the fan shell to protect against moisture • Variable frequency inverter balancing and reinforcement (frequency inverter by others). This option requires constant pitch drives. Model Q Fan — Arrangement 9 3 2 Model Number Description 12 Application Considerations 13 Selection Procedure 21 Performance Data 22 Dimensional Data and Weights 48 Mechanical Specifications 54 Features and Benefits This chart shows a typical NC level comparison between common vaneaxials, tubular centrifugals, airfoil centrifugals and the Trane Model Q™ compact fan. The shaded area represents range of vaneaxials tested. Trane Model Q fans require up to 85 percent less cubic space than airfoil centrifugal fans and 40 percent less than common vaneaxials of equivalent installed sound level. Floor space savings can be as much as 65 percent when compared to the common vaneaxial and airfoil centrifugal and 40 percent when compared to tubular centrifugals. Airfoil Centrifugal Fan Vaneaxial Fan Tubular Centrifugal Fan Trane Model Q Compact Fan 4 Features and Benefits Super Q II Plus More than twenty years after the introduction of the Model Q™, it still retains its reputation as one of the quietest HVAC fans in the world. This tradition of excellence continues with the introduction of a new Q fan acoustical enclosure and duct silencer so effective and so compact that we named it the Super Q II. Super Q II Fan Available with Model Q fans from 1,000 to 43,000 cfm, the Super Q II enclosure inhibits radiated fan and motor noise from entering the surrounding space. It internally isolates the fan on high deflection spring isolators so ductwork can be connected directly to the enclosure. It is uniquely designed to be floor or ceiling mounted with ease. Although the Model Q needs very little maintenance, future maintenance requirements were considered by Super Q II designers. Every unit has the bearing grease lines extended through the casing and every unit has two full size access panels that provide complete access to all internal components. Variable Air Volume Compatible The Super Q fan is modulated for VAV with variable frequency drives (by others), not with inlet vanes. Variable speed inverter fan modulation offers exceptional energy saving and exceptionally quiet part load operation. VAV variable speed Q fans are structurally reinforced to handle the uneven harmonic loadings associated with variable speed fan operation. In addition, the factory gives variable speed Q fans a precise, 10-point balance to further help assure troublefree operation. Only constant pitch drives should be used with variable frequency inverters. Super Q II 5 Super Q II Accessories • Inlet screen — safety accessory mounted to fan inlet. Heavy, plated steel wire • Inlet bellmouth — used with unducted or plenum applications. Improves air flow and reduces noise. • Inlet silencer (long or short) — rigid connection to Super Q fan • Outlet flow stabilization screen — small mesh outlet screen. Helps offset effect of poor outlet airflow conditions • Outlet silencer (short or long) — flex connected to Q fan • Variable frequency inverter balancing and reinforcement (frequency inverter by others). This option requires constant pitch drives. • Outlet screen — safety accessory mounted to fan outlet. Heavy, plated steel wire. Features and Benefits Trane Plus Duct Silencer The Plus option is a high performance duct silencer. Designed specifically for the Super Q II and Model Q™, it has several unique features that reduce airborne noise and turbulence to exceptionally low levels. Briefly, the Plus option develops maximum static regain while simultaneously limiting objectionable mid and high frequency noise. The Plus option should be used whenever quiet comfort is desired and the duct system is acoustically unable to provide it. Trane’s Plus Silencer provides significant noise attenuation, up to 32 db at 1,000 Hz, without a significant increase in fan horsepower requirements. By carrying the concept of noise source attenuation to its economic maximum, Trane has created a fan system that can move significant amounts of air without creating objectionable low frequency rumble. It provides proven acoustical performance with less design risk. In project after project, the Trane Model Q fan has been the key to creating NC 15 to NC 35 quiet comfort jobs. Beyond quiet, the Super Q II Plus system is small and compact. In fact, it is small and quiet enough that it can be successfully installed in ceiling plenums. Locating a Super Q II Plus in the plenum helps reduce and even eliminate the floor space needed for the mechanical room. Plus Silencer 6 The modular, component design approach of the Super Q II air handling system makes it exceptionally well suited for renovation, retrofit and replacement projects. The Super Q II air handling system components (fan, silencers, filter/coil module, etc.) fit through most doors and elevators and can be easily field-assembled into any system configuration (blow-thru, drawthru, etc.). Features and Benefits Low Sound Level, High Efficiency Provided by Unique Aerodynamic Features [9] Airfoil Vanes (stationary) [4] Airfoil Blade Wheel. [5] Aerodynamic Pitch [10] Stabilizing Pitch [7] Hub Streamlining Insulation [6] Minimum Tip Clearance [2] Aerodynamic Inlet Bell [12] End Cone [8] Exact Blade to Vane Spacing [11] Precise Divergent Angle Diffuser Discharge Cone [3] Aerodynamic Inlet Cone [1] Thin Strut Patented Bearing Support Precision cast fan wheel and diffuser for highly efficient aerodynamic performance. [8] Precise divergent angle for maximum static regain. [11] Note: Call-out numbers shown above are referenced on page 8. 7 Aerodynamic inlet provides smooth airflow. [3] Features and Benefits The low sound and high performance of the Trane Model Q™ fan are achieved by reducing noise-creating, energyconsuming turbulence within the fan. Airflow research and development techniques employed were similar to those used in perfecting today’s high performance axial flow jet engine compressors. The resulting smooth air path has made the Model Q the first vaneaxial fan to provide quiet, efficient operation, suitable for air conditioning duty. Aerodynamic Air Path A component by component analysis of the Model Q points to 12 aerodynamic features which are keys to a smooth air path. Starting at the inlet, the struts [1] of the patented bearing support are precisely positioned in relation to the fan blades. Air passing over the struts strikes the blades in a pattern that prevents blade whine. Precise Manufacturing Assures Performance — Advanced manufacturing techniques assure the same performance characteristics for each production Model Q fan. • Fin Struts — The fin struts of the patented bearing support are precisely positioned in relation to the fan blade. Air passing over the struts strikes the plate in a pattern that prevents the irritating whine, from blade frequency, which is characteristic of industrial vaneaxials. • Inlet Bell and Cone — The aerodynamically shaped inlet bell and inlet cone provide uniform axial flow into the fan parallel with the fan shaft. Air is delivered equally to the leading edge of the fan blades. This prevents crowding toward the blade tip. • Wheel — The wheel consists of 8 precision cast blades with a twisted radially projected shape and airfoil cross section. This radial projection utilizes a variable angle of attack in the radial dimension and prevents radial movement as the air particles move through the wheel. The aerodynamically shaped inlet bell [2] and inlet cone [3] provide uniform axial flow parallel to the fan shaft. Air is delivered equally to the leading edge of the fan blades — no crowding toward the fan tips. stabilization ahead of the vanes. The vanes themselves are precision cast aluminum and have an airfoil cross section [9] and a precise radial pitch [10]. This provides smooth, spiral-free discharge. Air separation is reduced by the precision cast aluminum airfoil cross section [4] of the fan blades. Blade pitch [5], using a variable angle of attack in the radial dimensions, is precisely controlled to prevent energy loss. Exceptionally close clearance [6] between the blade tips and housing reduces the eddy currents of fan tip recirculation. The reinforcing ring rigidizes the housing to maintain the tip clearance. The interior of the fan wheel is insulated to prevent hub strengthening protrusions from [7] windmilling in the airstream. The diffuser section design [11] is critical. A precisely determined diffusion angle produces the greatest possible static regain within the confines of the fan. An end cone [12) covers the fan drive assembly, thereby reducing the turbulence generated by air passing over exposed drives. A precisely controlled space [8] between the fan blades and diffuser vanes is necessary to allow airflow • Tip Clearance — Close clearance between the blade tips and housing reduces eddy currents due to tip recirculation. The reinforcing ring holds the housing in its precise shape to maintain proper clearance. • Vane Spacing — Precise space between the fan blades and the diffuser vanes is necessary to allow flow stabilization ahead of the vanes. The 29 diffuser vanes also have an airfoil cross section and a twisted, radially projected shape. This provides smooth, spiralfree air discharge. • Precision Cast Aluminum Fan and Diffuser — Being cast, blade and vane shapes are permanently and precisely fixed. They are not subject to misalignment or distortion as are welded, sheet metal forms. • Diffuser Section — The diffuser section design is critical. A precisely determined flare angle at the diffuser end produces the greatest possible static regain within the confines of the fan. Thus, externally mounted diffuser accessories, common for industrial vaneaxials, are not necessary. 8 • Hydraulically Expanded Flow- Formed Housing — In this process, the cylindrical housing is drawn to its final form over an expansion die. The metal, expanded beyond its elastic limit, permanently retains the precision form imparted by the die. • Ductile Weld Technique — This technique is required for the fan housing seam to guarantee success of the expansion forming process. The arc and “puddle” are submerged in molten flux that shields the weld material from oxidation. This prevents brittleness and also anneals the weld. The result is a flexible, ductile seam capable of being drawn and formed — another example of the advanced technology used in the Trane Model Q fan. Features and Benefits Saving Valuable Equipment Room Space The Trane Model Q™ and Super Q II fans can help you maximize your building’s usable floor space by using them in place of centrifugal fans. The smaller the equipment room, the more space left for tenants, merchandise, etc. Return or Exhaust Applications Figure F-1 shows a size 44, single width, low pressure airfoil centrifugal fan delivering 20,000 cfm of air. Because of its size and weight, it is floor mounted and connected to a return air plenum. In contrast, a 44-inch Model Q fan is used in Figure F-2 instead of a centrifugal fan. Its smaller size and lighter weight permits ceiling suspension and approximately 75 sq ft of floor space is freed up for other use. Figure F-1 Figure F-3 Figure F-2 Figure F-4 9 Draw-Thru Supply Application (Small Capacity) The fan system in Figure F-3 is a 27-inch, single width, medium pressure airfoil centrifugal fan rated at 9,000 cfm. Even though it is a relatively small fan, it is floor mounted beside the coil bank plenum. Figure F-4 shows a 27-inch Model Q substituted in place of the centrifugal. The small size and weight, plus the installation flexibility of the Model Q, permits mounting in a vertical position on top of the plenum. The space savings is about 25 sq ft. Features and Benefits Draw-Thru Supply Application (Large Capacity) A 60-inch, single-width, medium pressure airfoil centrifugal fan is used in the system illustrated in Figure F-5 to supply 45,000 cfm of air.This capacity can be easily achieved by installing a pair of 40-inch Model Q™ fans in parallel as shown in Figure F-6. The resulting floor space savings is approximately 85 sq ft! Figure F-5 Figure F-7 Figure F-6 Figure F-8 10 Blow-Thru Supply Application Figure F-7 shows a typical medium pressure, built-up, blow-thru system. The fan, enclosed in a plenum, is a 33inch, double width, airfoil centrifugal that delivers 30,000 cfm of air. The bulkiness of the plenum is dictated by the necessary clearances around the fan. To save floor space, a 44-inch Model Q replaces the centrifugal in Figure F-8. The suspended mounting of the Model Q frees about 70 sq ft for installation of pumps and other equipment. Features and Benefits Reduce Installed Cost By Up To 20 Percent The Trane Model Q™ fan, with all its precision and quality, is still a cost effective fan. When all necessary system components are considered, it provides substantial installation cost savings. In addition, its small size and variable mounting positions allow more freedom to the designer and installer. First Cost Comparisons True first cost is the total cost of an operable installation. With the Trane Model Q, this consists of only the fan, drive and isolation. By comparison, the airfoil centrifugal typically requires these three components, plus an integral base. In addition, cost of isolation for the airfoil is greater because it is typically twice as heavy as the Model Q. The common vaneaxial also requires more components in most applications. Besides the fan, drive and isolation, an inlet bell and diffuser are frequently necessary to meet cataloged performance. A sound attenuator is also required to reduce noise to a level equivalent to a Model Q fan without attenuation. Lower Installation Costs The Trane Model Q fan has fewer components to install and the advantage of lighter weight. With only half the weight of airfoil and tubular centrifugals, it requires less manpower for rigging and setting the fan in place. The result is reduced labor, with corresponding dollar savings on the typical job. Lighter weight also reduces inertia pad requirements. With the Model Q, a pad has to be considered only on large Class III fans. Airfoil and tubular centrifugals, because of greater weight, often require pads for Class I and II to minimize the effect imposed by normal vibration. Combined Saving Significant A comparison of average total installed cost is shown in Table F-1. Average cost figures were developed based on estimates by experienced installing contractors. In all cases, the Trane Model Q represents a significant savings. Table F-1 — Total Installed Cost Comparison Standard Centrifugal Item Required Trane Model Q Tubular Centrifugal Vaneaxial X First Cost Requirement Fan X X X Belt Guard X X X Integral Base X Inlet Bell X Attenuation X Spring Isolators X X X X X X X X Installation Cost Requirements Rigging Install Attenuation X Mount Motor (Etc.) X X Install Isolation X X X X Average Total Installed Cost X –5 +5 +15 Comparison is based on equal size fans of similar capacities. The airfoil centrifugal fan is used as base (100%) for comparative purposes. Figures are based on estimates by experienced installing contractors. Arrangement 9 Trane Model Q fan requires purchase of motor, motor rails, belt guard and isolation in addition to the basic fan. 11 Arrangement 3 airfoil centrifugal fan requires purchase of motor, belt guard, motor slide rail, isolation and subbase in addition to basic fan. Model Number Description Valid Prod. Cat. Selectable Item Description CYCLE QSE QSE1 QSQ MTO MTO1 MTO2 MTO3 E-cycle 16-44 arr 9 cl 1&2 w/o mtr mtd E-cycle 16-44 arr 9 cl1&2 w/mtr mtd Q-cycle 16-44 arr 9 cl 1,2&3 Std cycle 16-44 arr 1&9 cl 1,2&3 & SQ2 Std cycle 16-44 arr 1&9 w/unit coating Std cycle 49-60 arr 9 cl 1&2 Std cycle 49-60 arr 9 w/unit coating MODEL QFNA Q (Quiet) fan TYPE SQ2 Super Q2 fan QFAN Q fan SIZE 16 19 21 24 27 30 33 36 40 44 49 54 60 Fan size 16” (400 mm) Fan size 19” (475 mm) Fan size 21” (525 mm) Fan size 24” (600 mm) Fan size 27” (675 mm) Fan size 30” (750 mm) Fan size 33” (825 mm) Fan size 36” (900 mm) Fan size 40” (1000 mm) Fan size 44” (1100 mm) Fan size 49” (1225 mm) Fan size 54” (1350 mm) Fan size 60” (1500 mm) 9 1 Arrangement 9 fan Arrangement 1 fan ARRG CLASS 1 2 3 UORT UP Upblast discharge DOWN Downblast discharge H Horizontal discharge MTRS TT FT TF FF TRES DUCT Class 1 fan Class 2 fan Class 3 fan Trane supplied motor & Trane mounted Field supplied motor & Trane mounted Trane supplied motor & field mounted Field supplied motor & field •mounted WB Thrust restraints WB (direct ship) NONE No thrust restraints YES Duct canvas WBAL FACT Q fan inverter factory balancing FIELD Inverter ready balanced by customer Valid SelectProd. able Cat. Item Description Valid SelectProd. able Cat. Item Description MTHP 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 INSL F FA Fan insulation Fan and accessories insulation ENHA DBLE Double acoustic enhancement Motor hp 1 (.7 kW) Motor hp 1.5 (1 kW) Motor hp 2 (1.5 kW) Motor hp 3 (2 kW) Motor hp 5 (4 kW) Motor hp 7.5 (5.5 kW) Motor hp 10 (7 kW) Motor hp 15 (11 kW) Motor hp 20 (15 kW) Motor hp 25 (18 kW) Motor hp 30 (22 kW) Motor hp 40 (30 kW) Motor hp 50 (37 kW) Motor hp 60 (44 kW) Motor hp 75 (56 kW) MTYP HEOP18ODP High eff mtr 1800 rpm 1S/1W ODP12 ODP High eff mtr 1800/ 1200 rpm 2S/2W ODP91 ODP High eff mtr 1800/ 900 rpm 2S/1W ODP92 ODP High eff mtr 1800/ 900 rpm 2S/2W PHOP18ODP Prem Hi E+3 mtr 1800 rpm 1S/1W HETE18 TEFC High eff mtr 1800 rpm 1S/1W PHTE18 TEFC Prem Hi E+3 mtr 1800 rpm 1S/1W VOLT 200 208 230 460 575 200 Volt 60 hertz 3 ph motor 208 Volt 60 hertz 3 ph motor 230 Volt 60 hertz 3 ph motor 460 Volt 60 hertz 3 ph motor 575 Volt 60 hertz 3 ph motor MOLO R Motor location right hand drive Motor location left hand drive Motor location top drive Motor location bottom drive L T B GRSL N C Nylon grease lines Copper grease lines DTYP C1.2 Constant pitch drive with 1.2 DSFT Constant pitch drive with 1.4 DSFT Constant pitch drive with 1.5 DSFT Variable pitch drive with 1.2 DSFT Variable pitch drive with 1.4 DSFT Variable pitch drive with 1.5 DSFT C1.4 C1.5 V1.2 V1.4 V1.5 12 COAT BPI Baked phenolic (heresite) inside BPIO Baked phenolic (heresite) in/outside EI Epoxy inside EIO Epoxy inside/outside EPI Epoxy phenolic (2 components) inside EPIO Epoxy phenolic (2 components) inside/outside EPADI Epoxy phenolic (air dry heresite) inside EPADIO Epoxy phenolic (air dry heresite) inside/outside PEI Polyester (sanitile) inside PEIO Polyester (sanitile) inside/ outside IOPT IB IF ISC IBSC SH L IV NONE Inlet bell Inlet flange Inlet screen Inlet bell with inlet screen Inlet silencer short Inlet silencer long Inlet vanes No inlet options OOPT OFLG OSCN ODEQ ODOF Outlet flange Outlet screen Outlet duct equalizer Outlet duct equalizer w/ outlet flange SH Outlet silencer short L Outlet silencer long NONE No outlet options ISOL SLF Free standing spring floor isolators C Housed spring floor isolators ND Dbl deflection neoprene floor isolators RSL Spring rail floor isolators MSL Steel base w/spring floor isol KSL Concrete inertia base w/spring floor isolators HD Dbl deflection neoprene ceiling isolators HS Spring ceiling isolators DNHS Spring & neoprene ceiling isol WR Neoprene wall isolators ADOR MS OS 9R 9L Access door motor side Access door opp. motor side Access door 90° right of motor Access door 90° left of motor DRAN YES Drain MTGL IL OL Inlet mounting legs Outlet mounting legs Application Considerations This section assists the system designer in application and control of Trane Q and Super Q II fans. Satisfactory distribution of conditioned air requires a properly chosen fan and a well designed duct system. Abbreviations sp ...... static pressure (in. of water) vp ...... velocity pressure (in. of water) tp ....... total pressure (in. of water) ov ...... outlet velocity (ft per minute) rpm ... fan speed (revolutions per min.) bhp ... brake horsepower p ........ air density (lbs/ft3) db ...... decibel (sound power or sound pressure level) cps .... cycles per second cfm .... cubic feet of air per min. at any density scfm .. cubic feet per min. of standard air clean, dry air with a density of 0.075 lbs/ft3 at 70 F and a barometer reading of 29.92- inches Hg) The System An air system may consist of a fan, ductwork, air control dampers, cooling coils, heating coils, filters, diffusers, noise attenuation, turning vanes, etc. The fan is the component in the system which provides energy to the airstream to overcome the resistance to flow of the other components. System Curve At a fixed volume flow rate (cfm) through a given air system, a corresponding pressure loss, or resistance to this flow, will exist. If the flow rate is changed, the resulting pressure loss, or resistance to flow, will also change. The relationship governing this change for most systems is: PRESSUREc/PRESSURE = (CFMc/CFM)2 The characteristic curve of a typical “fixed system” plots as a parabola in accordance with the above relationship. Typical plots of the resistance to flow versus volume flow rate are shown with normalized duct system curves, Figure A-1. Figure A-1 — Normalized Duct System Curves System Component Losses Every system has a combined resistance to flow which is usually different from every other system and is dependent upon the individual components in the system. The determination of the “pressure loss” or “resistance to flow,” for the individual components can be obtained from the component manufacturers. The determination of pressure losses for ductwork and branch piping design is well documented in standard handbooks such as the ASHRAE Handbook of Fundamentals. 13 For a fixed system, an increase or decrease in system resistance results from an increase or decrease in the volume flow rate along the given system curve only. Refer to Duct System A, Figure A-1. Assume a system design point at 100 percent volume and 100 percent resistance. If the volume flow rate is increased to 120 percent of design volume, the system resistance will increase to 144 percent of the design resistance in accordance with the system equation. A further increase in volume results in a corresponding increase in system pressure. A decrease in volume flow to 50 percent results in a 75 percent reduction in design resistance. Application Considerations Performance Data Determination The fan performance section of this catalog contains a fan performance table and fan curve for each fan size. Figure A-2 — Point of Operation — Interaction of the System Curve and the Fan Performance Curve The performance data contained in this catalog was calculated from tests conducted in accordance with AMCA Standard 210 Laboratory Methods of Testing Fans for Rating. The AMCA test procedure uses an open inlet and 10 wheel diameters of straight discharge ductwork to assure maximum static regain. The fan is direct driven by a dynamometer. The fan performance tables in this catalog are based upon standard air: 0.075 lbs/ft3 (70 F, barometric pressure 29.92-inches Hg). Fan Performance Curves A fan performance curve is a graphical presentation of the performance of a fan. Usually it covers the entire range from free delivery (wide open cfm, no obstruction to flow) to no delivery (blocked tight, an airtight system with no air flowing). The point of intersection of the system curve and the fan performance curve determines the point of operation and actual flow volume. If the system resistance has been accurately determined and the fan properly selected, their performance curves will intersect at the design flow rate. Refer to Figure A-2. The normalized Duct System A from Figure A-1 has been plotted with a normalized fan performance curve. Figure A-3 — Air Density Corrections Temperature and Altitude Corrections The fan performance values in the tables and curves of this catalog are based on standard air (.075 lbs/ft3). If the airflow requirement for a particular job is stated in terms of nonstandard air, a density correction needs to be made before selecting the fan. It is important to also note that most air friction charts for ducts, filters, coils, etc. are also based on standard air and corrections must be made to determine proper losses at other conditions. Figure A-3 illustrates the ratio of air densities to standard air at various temperatures and elevations. A Q fan is designed for operation between -20 F and 150 F only. 14 Application Considerations The following is the procedure to use when selecting a fan for elevations and temperatures other than standard: 1 Determine the air density from Figure A-3. 2 Divide static pressure at the nonstandard condition by the air density ratio. 3 Use the actual cfm and corrected static pressure to determine rpm and bhp from the fan performance tables. 4 The rpm is correct as selected. 5 The bhp must be multiplied by the air density ratio determined in step one to get the actual operating bhp. Table A-1 — Q Fan/Super Q II Fan Installation Kt Corrections Unducted (Plenum) Inlet* Draw-Thru Type Design 0.0 Ducted Inlet Turn > 3 Dia Upstream -1.0 Turn 2 Dia Upstream +.8 Turn 1 Dia Upstream +1.3 Turn < 1 Dia Upstream Not Recommended Unducted Outlet Blow-Thru Type Design +.8 Ducted Outlet Turn > 2 Dia Downstream 0.0 Turn 1 Dia Downstream +1.3 Turn < 1 Dia Downstream Not Recommended Figure A-4 — Ducted Turns Near Q Fan Option and Installation Kt Corrections System effect losses due to less than ideal inlet or outlet configuration can be expressed in terms of velocity pressure by the following expression: Inlet SP Loss = Kti Velocity ( Inlet4005 ) 2 Table A-2 — Q Fan/Super Q II Fan Option Kt Corrections Where Kti = Inlet Option Kt + Inlet Installation Kt Outlet SP Loss = ( ) Kto Outlet Velocity 4005 2 Where Kto = Outlet Option Kt + Outlet Installation Kt Kt is the loss factor for the inlet or discharge condition being considered. It is necessary to add all of the static pressure loss determined from the above equation to the component static pressure to determine the point of duty static pressure for selection of the fan. Options Inlet Flange Inlet Bellmouth* Inlet Plus Silencer Inlet Screen Outlet Screen Outlet Flange Outlet Equalizer (Diffuser) Outlet Plus Silencer Outlet Flow Stabilization Screen Outlet Backdraft Damper Frequency Drive Modulation Belt Guard Motor Rails Standard Isolators Seismic Isolators Use Connects to bolted inlet duct Reduces Unducted Inlet Kt Reduces inlet noise Protects Unducted Inlets Protects Unducted Outlets Connects to bolted outlet duct Improves SE Reduces Outlet Noise Reduces Outlet swirl Isolates fan from duct Modulates Q Fan quietly Protects drives/belts Allows motor to be mounted Isolates fan Isolates fan Q-Fan X X X X X X X X X Special Special X X X X Super Q II Pressure Fan Drop (Kt) 0 X -.1 X +.1 X +.1 +.5 0 0 X +.1 X +.8 Special +.5 Special 0 0 Included 0 Included 0 Special 0 *Note: Bellmouth effect included in unducted installation Kt correction. Fan sizes 49 through 60 fan curves are cataloged with inlet bells. For unducted inlets without bells on size 49 through 60 fans add .1 to the inlet Kt given above. Inlet vane losses are covered in the Selection Procedure with air density corrections (page 20). Fan Option Kt Corrections The fan static pressure should be adjusted for fan options. Option pressure drops are documented as Kt losses and are handled the same way as installation Kt effects (losses). Use Table A-1, Q Fan/Super Q II Fan Kt corrections, to determine the Kt values. Add these values to any installation Kt values. Use the result to select the fan. 15 Application Considerations Q and Super Q II Fan Modulation — AC Inverter Capacity Control Q fans and Super Q II fans can be modulated with AC frequency drives. The Trane Company recommends Magnetek low noise inverter drives and Century high efficiency motors for optimum modulation performance. Operating the Q or Super Q II fan on AC frequency drives requires the Q fan to be strengthened and balanced in the factory. This option “beefs up” the mechanical bracing of the Q fan inlet bearing assembly and calls for a precision factory balance. Precision balancing covers 10 operating points on the system curve from 10 percent load to full load. Minimum cfm with AC inverters — Above 1.5” static pressure, the minimum cfm is the surge (do not select) line. Below 1.5” static pressure, it is 1000 cfm. Q Fan Modulation — Inlet Vanes Inlet vanes are a widely used form of fan modulation. As inlet vanes close, they impart a spin on the incoming air in the direction of the fan wheel rotation. This reduces airflow, static pressure and brake horsepower. However, inlet vanes do increase sound levels. If a job is acoustically sensitive, AC inverters are recommended for modulation. As shown in Figure A-5, a separate cfm static pressure curve (cfm-sp) is generated per each inlet vane position. Likewise, the figure shows brake horsepower curves that apply for various inlet vane positions. As VAV terminal units begin to close in response to a decreasing cooling load, static pressure in the ductwork increases. This causes the fan operating point to temporarily move upward to the left on a constant rpm curve as shown in Figure A-5 (point A to point B). The static pressure sensor will detect an increase in duct pressure and signal the inlet vane operator to begin to close the vanes. The inlet vanes will close until the static pressure sensor is again satisfied, moving the operation point to C (Figure A-5). As the cooling load continues to decrease, the modulation curve will be formed (point C to D, and point D to E) on Figure A-5. This curve passes through the design point and through the static pressure sensor control point. The static pressure of any point on this curve can be calculated using the formula: Sp = (Cfm/Cfmd)2 x (SPd-SPc) = SPc SPd = static pressure at design, SPc = static pressure control setting, Cfmd = cfm at design. Figure A-5 – VAV System Modulation Curve Inlet vanes are controlled by placing a static pressure sensor in the downstream ductwork, typically about two-thirds of the way down the longest trunk duct. This sensor is set at a static pressure that will ensure sufficient pressure is available to move air from that point through the remaining duct work. The sensor will respond to duct pressure changes and signal the inlet vane operator to open or close the vanes to maintain the control setting at the sensor location. 16 The VAV system modulation curve can be drawn using a Trane system modulation overlay. The axis of the overlay is placed on a static pressure control setting. The curve that intersects the design points is the system modulation curve. Because the axes of the inlet vane performance graph are in terms of percent wide open cfm (wocfm) and percent peak static pressure, the first step in establishing the system modulation curve is to find the proper design points. By plotting the design point on the performance curve for the fan in question, one can easily determine the percent wocfm. Knowing this, plot a point on the cfm-sp curve (Figure A-6) for inlet vanes wide open, at the design point of wocfm. By tracing to the left, one can determine the percent of peak static pressure. By knowing the design cfm, static pressure and the percent of wide open cfm and percent peak static that these values represent, one can calculate wocfm and peak static pressure. Application Considerations The control static pressure can then be expressed as a percent of peak static pressure and plotted. The system modulation curve is described by the curve on the modulation overlay that passes through the design point when the axis is placed on the control static pressure point. The minimum inlet vane cfm can easily be determined after the system modulation has been established. It will be one of two things, either a) the point where the system modulation curve intersects the surge line, or b) 40 percent wocfm, whichever is greater. Forty percent wocfm is the minimum point a Q fan with inlet vanes can modulate, due to inherent instability that results when the vanes close to a certain angle. Part load fan power consumption with inlet vanes can be determined by entering Figure A-6 at the desired percent wide open cfm. (Wide open cfm is found on the fan curve by following the fan rpm to the right until it intersects the 0” static pressure axis.) On Figure A-6, plot a system curve from the control static pressure through the point of operation defined as a calculated percent wide open cfm. Read vertically upward from the 25, 50 and 75 percent intersections to determine the percent bhp at part load. Intermediate operating points are found by extrapolation. Inlet vanes increase Q fan sound levels. See Table A-5. Figure A-6 – Inlet Vane Performance A plot of part load cfm versus brake horsepower can also be made after the system modulation curve is established. At each intersection of the system modulation curve with a cfm-sp curve for a certain inlet vane opening, a vertical line is traced to the appropriate bhp-cfm curve. At each intersection of a bhp-cfm curve, a horizontal line is traced to the scale of percent brake horsepower. This will lead to a percent wocfm versus percent peak bhp plot. The design rpm and bhp need to be corrected to account for performance losses due to inlet vanes being in the air stream. A correction of one percent to the rpm and three percent to the bhp is made in order to get to design conditions with the inlet vanes fully open. 17 Application Considerations Table A-3 — Maximum Torque For Operation Of InletVanes Size Class 1 16 2 3 1 19 2 3 1 21 2 3 1 24 2 3 1 27 2 3 1 30 2 3 1 33 2 3 1 36 2 3 1 40 2 3 1 44 2 3 Control Arm (In.) 8.75 8.75 8.75 8.75 8.75 8.75 8.75 10.81 10.81 10.81 Opening Torque (In.-Lb) 8 14 23 12 21 34 17 31 32 26 48 79 37 66 109 52 94 155 65 128 212 100 180 298 138 249 412 193 349 576 Closing Torque (In.-Lb) 7 13 22 11 19 31 15 26 44 20 36 61 27 48 79 35 63 104 41 81 134 59 106 175 75 136 225 99 179 295 Motor and Drive Selection The Model Q fan has been designed for use with NEMA “T” Frame motors. Motor hp limits for Class I, II, and III construction are listed in the roughing-in Dimensional Data section of this catalog. Table A-4 defines this constant system curve as a percent of wideopen cfm. If fans in parallel are always operated to the right of this constant system curve, fan paralleling will not occur. Table A-4 — Parallel Operation Fan Size 16 19-21 24-30 33-44 49-60 Minimizing belt tension forces increases bearing life and reduces fan noise. The Q fan and Super Q II fan drive selection is totally computerized by the factory to achieve quiet, long life operation. If Trane provides Q fan drives, all fan motor information must be made available to the Trane sales engineer. Minimum % of WOCFM For Two Model Q Fans In Parallel 80% WOCFM 81% WOCFM 83% WOCFM 73% WOCFM 85% WOCFM Figure A-7 — Selecting Model Q Fans in Parallel Parallel Fan Operation The Q fan performance curve has a characteristic shape where two different cfm’s are possible at the same static pressure. Therefore, when selecting fans for multiple installation connected with either a common inlet, a common discharge or both, care must be taken to eliminate the possibility of fan paralleling. Figure A-7 shows two typical cfm-sp performance curves for the Q fan. Fan paralleling can occur when multiple fans are selected in the shaded area. Recommended Q Fan Configuration Inside an Air Handler The shaded area is determined by going straight across from the lowest point of the fan performance curve at the left of the surge line (A and A1) to the same curve to the right of the surge line (B and B1). Points B and B1 fall on a constant system curve. Side View 18 Application Considerations Recommended Super Q II (NC40) Plenum Configuration Recommended Super Q II Multiple Fan (NC40) Low Height Plenum Configuration Recommended Super Q II Quiet (NC35) Floor-Mounted (Stacked) Configuration Operating Cost/Efficiency The quiet Q fan is a very efficient fan. The Q fan mixed-flow type airfoil thrust blades offer outstanding efficiency and operating cost savings over such fan types as plug fans. Designers can compare the Q fan efficiency with other fans by using the fan selection program and the Trane Customer Direct Service (C.D.S.™) Network FanMod program. The Trane fan selection program provides accurate part load energy consumption no matter what fan modulation method is selected. The FanMod program compares two or more fans economically for one or more years. FanMod is an easy-to-use program for equipment life cycle cost analysis. 19 When comparing the Q fan performance with centrifugal fans, remember to recalculate the fan external static pressure. The in-line delivery of the Q fan often eliminates the need for a 90 degree turn right off the fan outlet. Turns directly downstream of the fan outlet consume energy and generate noise and, therefore, should be avoided whenever possible. Application Considerations Q Fan Sound Data Trane Q fans are designed to be used in any installation where a standard airfoil centrifugal fan can be used. The sound level of the Q fan in the difficult to attenuate lower frequencies is lower than that produced by standard airfoil centrifugal fans with the same capacity. Sound levels in the higher octave bands compare favorably. Therefore, the Q fan will provide quieter sound levels in a typical installation. Designing the system for lower static pressures and selecting the fan at high efficiency will result in quieter fan operation, as well as power savings. The best method of acoustical design makes use of unit sound power levels in all eight octave bands. These sound power levels for each Trane Q fan can be obtained from the Trane computerized fan selection program. In the past, it has been an industry practice to test air moving devices within a reverberating room to determine total sound power. This has presented the problem of distinguishing between inlet and discharge sound power ratings, where significant differences do exist. Trane engineers solved this problem by locating the fan adjacent to the reverberating room and ducting to it. By turning the fan around, inlet and discharge sound power can be measured separately and accurately. By ducting both the inlet and outlet, radiated shell sound power was determined. Using this method with the Trane reverberant room that conforms to ASHRAE standards, acoustical data on the Q fan is substantially more accurate than fan ratings made using conventional techniques. Tests covered all sizes and speeds over the entire performance range of the line. A computer program was then used to determine the precise relationship of speed, size, point of operation and frequency. Trane Acoustics Program Trane has a system level acoustics computer program that accurately converts fan sound power to room NC levels. This program uses ASHRAE approved algorithms and is the most complete and accurate sound predictive program in the HVAC industry. Use of the Trane acoustics program allows all sound paths to be checked and attenuated to achieve the desired room sound levels without costly overdesigning. Contact your Trane sales engineer for more details on this Customer Direct Service (C.D.S.) Network program. Q Fan/Super Q II Plus Silencers Trane has a unique silencer for the Q fan. This low turbulence, high attenuation silencer dramatically reduces airborne noise from the Q-Fan. A bulleted cylindrical silencer attenuates medium and high frequency noise generated by the Q Fan to a point where the Q Fan can be successfully installed in such sound sensitive applications as ceiling plenums successfully. Trane’s Plus silencer has a field repositionable bullet (center body) that can be relocated close to the Q Fan outlet. This unique feature eliminates low frequency turbulence and makes the Q fan quieter than plug fans or other axial or mixed flow fans. Pressure drop through the Plus silencer is approximately .1-inch sp. The Plus silencer has been used on many projects in the last five years to consistently create NC 15-35 spaces. Plus silencer attenuation is shown in Tables S-1 and S-2. Use the Trane fan selection program to obtain precise Plus attenuation with regenerated noise included. Trane ASA10B Sound Analyzer Trane offers a low cost 10 octave band sound analyzer for sound measurements. Capable of measuring noise from 30 to 123 db sound pressure with flat, dbA and dbC sound LCb weightings this rugged meter permits comparative and absolute sound measurements to be taken. Ideas On How To Use The ASA10B The ASA10B can be used on existing jobs to measure equipment sound levels by octave bands. Compare this data with NC charts to determine what frequencies need to be attenuated and by how much. The type and cost of noise control options is a function of the problem frequency and amplitude. On acoustical retrofits, the ASA10B can accurately compare before and after noise levels. Real measurements establish the benefit of the retrofit. Table A-5 — Inlet Vane Sound Data Octave Band 1 2 3 4 5 6 7 8 MidFrequency 63 125 200 500 1,000 2,000 4,000 8,000 20 Wide Open +4 +8 +7 +4 0 0 0 0 DB Addition For Vane Position Indicated 75% 50% 25% W/Open W/Open W/Open +8 +12 +14 +9 +9 +10 +8 +9 +9 +5 +6 +6 0 0 0 0 0 0 0 0 0 0 0 0 Selection Procedure 1 Select the type of fan desired. The Super Q II should be used where fan radiation noise needs to be attenuated. 2 Position the Q fan to deliver air to the system and minimize adverse Kt effects. Straight-thru flow arrangements are best. 3 Select the desired Q fan or Super Q II fan options. 4 Compute the fan external static pressure and cfm requirements. 5 Determine which Kt effects apply to the Q fan installation. 6 If the Q fan is serving a VAV system, select AC frequency drive or inlet vane modulations. (AC frequency drive modulation is considerably quieter and more efficient than Q fan inlet vanes.) Super Q II fans use AC frequency drive modulation only. 7 Input the selection parameters into the Trane fan selection program and select the desired Q fan or proceed with a manual selection. 8 Manual Selection: a Determine the air density ratio if nonstandard air is being handled by the Q fan. b Adjust the external sp by the air density ratio. c Use the inlet and outlet area of the fan to calculate the inlet and outlet velocities. Use these velocities and the inlet and outlet Kt to correct the external static pressure to the right value. Reselect the fan at the right value. d From the performance table, select the desired fan. 9 If inlet vane modulation was selected, increase the rpm by 1 percent and increase the bhp by 3 percent. 10 If the air density ratio is nonstandard (different than 1.00), the rpm is correct and the bhp must be multiplied by the air density ratio. 11 If the start-up air temperature is lower than the normal operating temperature, adjust the fan curve bhp for the starting temperature. The next larger nominal hp motor is the correct motor size. 12 If exceptional quiet is desired, choose a short or long Q fan plus duct silencer. The plus silencer is a low turbulence, low pressure drop, high attenuation duct silencer. Subtract the attenuations given in Tables S-1 and S-2 from the Q fan/Super Q II fan sound power projections. If silencer regenerated noise is a concern, contact your local Trane sales engineer for further information. Table S-1 — Short Plus Silencer Attenuation (1D Length)* Fan Size 16 19 21 24 27 30 36 40 44 63 Hz 2 2 2 3 3 4 4 5 5 Q-Fan Sound Power By Octave Band At Nominal Cfm/SP 125 HZ 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 3 10 16 19 20 13 3 10 16 19 19 13 4 10 16 19 19 13 4 10 16 19 19 13 5 10 16 19 19 13 5 10 16 19 17 13 6 10 16 19 15 13 6 11 16 19 14 12 6 11 16 19 14 11 8000 Hz 12 12 11 10 9 9 9 9 9 Table S-2 — Long Plus Silencer Attenuation (2D Length)* Fan Size 16 19 21 24 27 30 36 40 44 63 Hz 3 3 4 5 6 7 8 9 9 Q-Fan Sound Power By Octave Band At Nominal Cfm/SP 125 HZ 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 6 19 32 37 39 26 6 19 32 37 37 26 7 19 32 37 37 26 8 19 32 37 37 26 9 19 32 37 37 26 9 20 32 37 34 26 11 20 32 37 30 25 11 21 32 37 28 23 12 21 32 37 28 22 8000 Hz 24 24 22 20 18 18 18 18 18 *Approximate attenuations. Use the Trane Fan Selection Program for attenuation predictions that include silencer regenerated self-noise. NOTE: Super Q II not available with Class III fans. 21 Fan Size 16” Wheel Dia. Inlet Area Outlet Area Tip Speed 16.5 inches 2.05 square feet 1.70 square feet 4.32 x RPM ft./minute Performance Data Q Fan and Super Q II Size 16 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 419 mm 0.190 m2 0.158 m2 1.317 m/minute Maximum RPM 2585 3460 4660 Motor 1800 RPM 1200 RPM Minimum Fan RPM 486 324 Table P-1 — Size 16 Q-Fan CFM Std. Air 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 Outlet Vel. 588 705 823 941 1058 1176 1294 1411 1529 1647 1764 1882 2000 2117 2235 2352 2470 2588 2705 2823 2941 3058 3176 3294 /4” RPM 934 1071 1214 1360 1509 1660 1812 1965 2120 2274 2430 2586 2742 2898 3055 3212 3369 3526 3684 3841 3999 4157 4314 4472 BHP 0.08 0.12 0.16 0.22 0.30 0.39 0.50 0.62 0.77 0.95 1.15 1.38 1.63 1.92 2.24 259 298 3.41 3.88 4.39 4.95 5.55 6.20 6.89 /8” RPM BHP 1002 0.11 1127 0.14 1263 0.20 1404 0.26 1548 0.34 1695 0.43 1844 0.54 1995 0.68 2147 0.83 2300 1.01 2454 1.21 2608 1.44 2763 1.70 2918 1.99 3074 2.32 3230 2.68 3386 3.07 3543 3.50 3699 3.98 3856 4.49 4013 5.05 4170 5.65 4328 6.31 4485 7.01 /2” RPM BHP 1068 0.13 1184 0.17 1311 0.231 1447 0.30 1587 0.38 1731 0.48 1877 0.59 2025 0.73 2175 0.89 2326 1.07 2478 1.28 2630 1.51 2784 1.77 2938 2.07 3093 2.40 3248 2.76 3403 3.16 3559 3.59 3715 4.07 3871 4.59 4027 5.15 4184 5.76 4341 6.42 4498 7.12 /8” RPM BHP 1137 0.16 1239 0.20 1360 0.26 1489 0.33 1626 0.42 1766 0.52 1909 0.64 2054 0.78 2202 0.94 2351 1.13 2501 1.34 2653 1.58 2805 1.85 2958 2.15 3112 2.48 3266 2.84 3420 3.25 3575 3.69 3730 4.17 3886 4.69 4042 5.26 4198 5.87 4354 6.53 4511 7.24 Total Static Pressure /4” 1” RPM BHP RPM BHP 1204 0.19 1344 0.27 1295 0.24 1408 0.31 1408 0.29 1502 0.37 1531 0.37 1617 0.45 1662 0.46 1739 0.54 1800 0.57 1867 0.65 1941 0.69 2002 0.78 2084 0.84 2142 0.94 2229 1.00 2283 1.12 2376 1.19 2427 1.32 2525 1.41 2573 1.54 2675 1.65 2720 1.79 2826 1.92 2868 2.07 2978 2.22 3018 2.38 3130 2.56 3168 2.72 3284 2.93 3319 3.10 3437 3.34 3471 3.52 3591 3.78 3624 3.97 3746 4.26 3777 4.46 3901 4.79 3931 5.00 4056 5.36 4085 5.57 4212 5.98 4239 6.20 4367 6.64 4394 6.87 4523 7.36 4549 7.59 CFM Std. Air 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 Outlet Vel. 941 1058 1176 1294 1411 1529 1647 1764 1882 2000 2117 2235 2352 247C 2588 2705 2823 2941 3058 3176 2 1/4” RPM BHP 2040 0.94 2112 1.04 2205 1.18 2307 1.33 2425 1.50 2546 1.71 2671 1.94 2801 2.20 2935 2.49 3074 2.83 3213 3.18 3354 3.57 3497 3.99 3641 4.44 3786 4.94 3932 5.47 4079 6.04 4228 6.66 4377 7.32 4526 8.03 2 1/2” RPM BHP 2129 1.06 2188 1.16 2274 1.30 2369 1.45 2478 1.63 2598 1.84 2720 2.07 2846 2.34 2977 2.63 3112 2.96 3251 3.34 3390 3.74 3531 4.17 3674 4.63 3818 5.13 3963 5.67 4109 6.25 4256 6.88 4404 7.55 4553 8.27 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 2343 2407 2495 2590 2698 2817 2938 3063 3192 3324 3460 3601 3740 3881 4024 4168 4313 4459 4605 2482 2546 2616 2705 2801 2909 3028 3149 3272 3400 3532 3666 3806 3944 4085 4226 4369 4513 4658 CFM Std. Air 2600 2700 2800 2900 3000 3100 3200 3300 3400 3500 3600 3700 3800 3900 4000 4100 Outlet Vel. 1529 1588 1647 1705 1764 1823 1882 1941 2000 2058 2117 2176 2235 2294 2352 2411 7” RPM 3548 3568 3593 3622 3656 3694 3740 3783 3829 3876 3923 3973 4026 4081 4137 4198 7 1/2” RPM BHP 8” RPM BHP 8 1/2” RPM BHP Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 3674 3694 3719 3749 3783 3821 3866 3909 3954 4001 4049 4097 4149 4203 4259 3797 3817 3843 3872 3906 3944 3989 4032 4077 4124 4171 4219 4271 4324 3916 3937 3963 3993 4027 4065 4106 4153 4198 4244 4292 4339 4390 3980 4033 4055 4081 4111 4145 4183 4224 4272 4316 4362 4410 4457 4239 8.29 4259 8.46 4282 8.64 4309 8.84 4340 9.04 4375 9.27 4414 9.51 4459 9.81 4503 10.08 4547 10.37 4593 10.66 4348 4368 4392 4420 4452 4487 4526 4572 4615 4660 4400 4455 4476 4501 4530 4562 4598 4637 1 3 BHP 4.86 4.98 5.11 5.25 5.41 5.58 5.78 5.98 6.18 6.39 6.62 6.85 7.10 7.35 7.61 7.88 5.40 5.53 5.67 5.82 5.99 6.17 6.39 6.60 6.81 7.04 7.27 7.53 7.78 8.05 8.32 1 1.42 1.54 1.71 1.90 2.11 2.35 2.62 2.93 3.27 3.64 4.05 4.52 5.01 5.53 6.09 6.68 7.33 8.01 8.75 5.97 6.11 6.26 6.42 6.59 6.79 7.02 7.24 7.47 7.71 7.96 8.23 8.50 8.78 5 1.66 1.82 1.98 2.18 2.40 2.65 2.93 3.24 3.59 3.97 4.39 4.85 5.38 5.92 6.50 7.12 7.78 8.48 9.23 6.55 6.71 6.87 7.04 7.23 7.43 7.65 7.91 8.15 8.41 8.67 8.95 9.24 3 2688 2741 2816 2908 3005 3114 3233 3353 3477 3604 3734 3868 4004 4144 4284 4425 4567 2.12 2.28 2.47 2.71 2.97 3.25 3.57 3.92 4.31 4.74 5.21 5.72 6.27 6.91 7.55 8.22 8.95 6.85 7.17 7.33 7.50 7.68 7.88 8.10 8.33 8.61 8.86 9.13 9.41 9.71 2869 2930 3013 3104 3203 3313 3433 3553 3677 3803 3933 4066 4201 4341 4480 4620 2.60 2.78 3.02 3.29 3.58 3.91 4.27 4.66 5.10 5.58 6.10 6.67 7.27 7.97 8.67 9.41 4091 7.45 4147 7.80 4169 7.97 4196 8.16 4227 8.35 4261 8.56 4299 8.79 4340 9.04 4388 9.33 4433 9.60 4478 9.88 4526 10.17 1 1/4” RPM BHP 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 1523 1601 1698 1814 1936 2064 2197 2337 2477 2620 2764 2910 3057 3206 3355 3505 3656 3808 3961 4113 4267 4420 4574 1642 1697 1785 1886 2004 2127 2254 2387 2526 2666 2808 2951 3096 3243 3391 3539 3689 3839 3990 4142 4294 4447 4600 1796 0.64 1898 1870 0.72 1953 1961 0.831 2039 2068 0.95 2135 2188 1.10 2249 2311 1.27 2369 2440 1.46 2493 2573 1.68 2622 2712 1.94 2755 2851 2.22 2894 2993 2.53 3033 3136 2.86 3174 3280 3.23 3317 3426 3.63 3461 3573 4.07 3607 3721 4.54 3754 3870 5.06 3901 4020 5.62 4050 4171 6.22 4199 4322 6.87 4349 4473 7.56 4500 4626 8.31 4651 0.39 0.45 0.53 0.63 0.74 0.88 1.04 1.23 1.44 1.67 1.93 2.22 2.54 2.89 3.28 3.70 4.16 4.66 5.20 5.79 6.42 7.10 7.83 0.48 0.54 0.62 0.73 0.84 0.99 1.15 1.34 1.57 1.81 2.08 2.37 2.70 3.06 3.45 3.88 4.35 4.86 5.41 6.00 6.64 7.33 8.06 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 2999 3046 3114 3203 3296 3396 3507 3628 3748 3872 3998 4128 4260 4395 4535 3164 3220 3296 3387 3481 3586 3698 3819 3940 4064 4190 4319 4452 4586 3284 3328 3393 3479 3569 3665 3772 3889 4008 4129 4253 4379 4508 4641 2.94 3.12 3.34 3.62 3.92 4.26 4.63 5.03 5.47 5.96 6.50 7.07 7.68 8.35 9.11 3.48 3.69 3.96 4.28 4.63 5.00 5.41 5.86 6.35 6.89 7.48 8.11 8.78 9.50 8.96 9.14 9.33 9.54 9.76 10.00 10.26 10.57 10.86 11.16 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 22 0.75 0.82 0.93 1.06 1.21 1.38 1.58 1.81 2.06 2.36 2.68 3.02 3.40 3.81 4.25 4.74 5.26 5.83 6.44 7.09 7.80 8.55 3.85 4.07 4.32 4.65 5.00 5.39 5.81 6.26 6.76 7.30 7.89 8.54 9.22 9.95 9.24 9.65 9.85 10.05 10.27 10.50 10.76 11.03 3438 3492 3565 3655 3748 3847 3955 4074 4193 4315 4438 4565 4501 4560 4582 4608 4637 4.46 4.71 5.01 5.39 5.77 6.21 6.67 7.18 7.72 8.32 8.98 9.67 9.92 10.37 10.57 10.79 11.02 Performance Data Q Fan and Super Q II Size 16 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1-2 — Q Fan Size 16” Min - Max Motor HP Class 2 1.5 - 5 — Min - Max Motor HP Class 3 5 - 15 5 - 15 23 Super Q Fan Size 16” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1-2 1.5 - 5 NA NA Fan Size 19” Wheel Dia. Inlet Area Outlet Area Tip Speed 19.0 inches 2.61 square feet 2.30 square feet 4.97 x RPM ft./minute Performance Data Q Fan and Super Q II Size 19 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 483 mm 0.242 m2 0.214 m2 1.515 m/minute Maximum RPM 2345 3145 4040 Motor 1800 RPM 1200 RPM Minimum Fan RPM 417 278 Table P-2 — Size 19 Q Fan CFM Std. Air 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 Outlet Vel. 869 956 1043 1130 1217 1304 1391 1478 1565 1652 1739 1826 1913 1999 2086 2173 2260 2347 2434 2521 2608 2695 2782 2869 /4” RPM BHP 907 0.15 977 0.18 1049 0.22 1123 0.26 1198 0.31 1273 0.36 1350 0.42 1427 0.49 1504 0.57 1582 0.66 1660 0.75 1738 0.86 1817 0.97 1896 1.09 1974 1.23 2053 1.37 2133 1.53 2212 1.70 2291 1.88 2371 2.08 2450 2.29 2530 2.51 2610 2.75 2689 3.00 /8” RPM BHP 962 0.19 1026 0.23 1093 0.27 1163 0.31 1234 0.36 1307 0.42 1381 0.48 1456 0.55 1531 0.64 1608 0.72 1684 0.82 1761 0.93 1839 1.04 1916 1.17 1994 1.31 2073 1.46 2151 1.62 2229 1.79 2308 1.98 2387 2.17 2466 2.39 2545 2.61 2624 2.85 2704 3.11 /2” RPM BHP 1019 0.24 1078 0.28 1140 0.32 1205 0.36 1272 0.42 1342 0.48 1413 0.54 1486 0.62 1559 0.70 1634 0.79 1709 0.89 1785 1.00 1861 1.12 1938 1.25 2015 1.39 2092 1.54 2169 1.71 2247 1.88 2325 2.07 2404 2.27 2482 2.49 2560 2.72 2639 2.96 2718 3.22 /8” RPM BHP 1074 0.29 1129 0.33 1187 0.37 1248 0.42 1312 0.48 1378 0.54 1446 0.61 1517 0.69 1588 0.77 1661 0.86 1734 0.97 1809 1.08 1884 1.20 1959 1.33 2035 1.48 2111 1.63 2188 1.80 2265 1.98 2343 2.17 2420 2.37 2498 2.59 2576 2.82 2654 3.07 2732 3.33 Total Static Pressure /4” 1” RPM BHP RPM BHP 1124 0.34 1235 0.45 1179 0.38 1272 0.49 1234 0.43 1325 0.55 1292 0.48 1378 0.60 1352 0.54 1433 0.67 1415 0.60 1491 0.74 1481 0.67 1551 0.82 1548 0.75 1614 0.90 1617 0.84 1679 0.99 1688 0.94 1745 1.09 1760 1.04 1813 1.20 1833 1.16 1883 1.32 1907 1.28 1954 1.45 1981 1.42 2026 1.59 2056 1.56 2098 1.74 2131 1.72 2172 1.91 2207 1.89 2246 2.08 2283 2.07 2320 2.27 2360 2.26 2396 2.47 2437 2.47 2471 2.68 2514 2.69 2547 2.90 2592 2.93 2623 3.14 2669 3.18 2700 3.40 2747 3.44 2777 3.67 1 1/4” RPM BHP 1351 0.57 1375 0.62 1409 0.67 1456 0.73 1512 0.80 1566 0.88 1622 0.97 1681 1.06 1741 1.15 1804 1.26 1868 1.37 1934 1.50 2002 1.63 2071 1.78 2142 1.93 2213 2.10 2285 2.28 2358 2.47 2432 2.67 2506 2.89 2580 3.12 2655 3.37 2731 3.63 2806 3.90 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 1481 1505 1538 1583 1638 1692 1747 1804 1864 1925 1988 2053 2119 2186 2256 2326 2397 2469 2541 2614 2688 2762 2837 1602 1627 1660 1704 1759 1812 1867 1923 1982 2042 2104 2168 2233 2299 2367 2436 2506 2577 2649 2721 2794 2868 CFM Std. Air 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 7400 Outlet Vel. 1217 1304 1391 1478 1565 1652 1739 1826 1913 1999 2086 2173 2260 2347 2434 2521 2608 2695 2782 2869 2956 3043 3130 3217 2 1/4” RPM BHP 1826 1.42 1853 1.52 1887 1.60 1931 1.70 1987 1.84 2040 1.97 2094 2.11 2150 2.27 2207 2.42 2266 2.58 2327 2.76 2389 2.94 2453 3.14 2518 3.35 2584 3.57 2651 3.81 2720 4.06 2789 4.33 2859 4.61 2930 4.90 3002 5.21 3075 5.54 3147 5.88 3221 6.24 2 1/2” RPM BHP 1908 160 1930 170 1959 1.79 1994 1.89 2040 2.01 2096 2.16 2149 2.31 2203 2.46 2259 2.63 2316 2.80 2374 2.98 2434 3.17 2496 3.37 2559 3.59 2624 3.81 2690 4.05 2756 4.31 2824 4.58 2893 4.86 2963 5.16 3033 5.48 3104 5.81 3176 6.16 3249 6.53 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 2105 2130 2162 2201 2249 2306 2359 2413 2469 2525 2584 2644 2704 2767 2831 2896 2962 3028 3096 3165 3235 3305 2267 2290 2320 2355 2399 2449 2507 2561 2615 2671 2728 2786 2846 2906 2968 3031 3096 3162 3227 3295 3363 2419 2442 2470 2503 2544 2592 2649 2702 2756 2811 2867 2924 2982 3042 3102 3164 3227 3292 3357 3423 2702 2725 2751 2783 2819 2863 2912 2971 3024 3078 3132 3188 3245 3303 3362 3422 3482 3544 4.56 4.74 4.95 5.14 5.32 5.56 5.82 6.14 6.44 6.74 7.06 7.40 7.74 8.09 8.45 8.83 9.22 9.63 2835 5.26 2858 5.46 2883 5.70 2915 5.91 2949 6.10 2992 6.35 3040 6.63 3099 6.99 3152 7.31 3205 7.64 3260 7.98 3315 8.35 3371 8.72 3428 9.10 3487 9.49 3546 9.89 3605 10.31 2962 6.01 2985 6.23 3085 6.80 3011 6.49 3108 7.04 3042 6.72 3134 7.32 3076 6.92 3166 7.57 3118 7.19 3199 7.79 3166 7.49 3241 8.08 3224 7.87 3288 8.40 3277 8.22 3339 8.76 3330 8.58 3398 9.19 3384 8.95 3452 9.57 3439 9.35 3505 9.96 3494 9.75 3560 10.37 3551 10.15 3615 10.82 3609 10.57 3672 11.26 3668 11.00 3729 11.70 CFM Std. Air 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 7400 7600 7800 Outlet Vel. 2086 2173 2260 2347 2434 2521 2608 2695. 2782 2869 2956 3043 3130 3217 3304 3391 7” RPM BHP 3205 7.63 3227 7.93 3254 8.20 3286 8.46 3319 8.70 3361 9.01 3407 9.35 3458 9.73 3518 10.20 3571 10.61 3625 11.03 3679 11.47 3734 11.95 3790 12.41 3847 12.89 3905 13.38 7 1/2” RPM BHP 8” RPM BHP 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 3321 8.50 3343 8.83 3371 9.12 3403 9.40 3436 9.65 3478 9.98 3524 10.35 3575 10.76 3635 11.26 3688 11.69 3741 12.14 3796 12.61 3850 13.12 3906 13.62 3963 14.12 3412 3434 3457 3485 3517 3551 3593 3639 3689 3750 3803 3856 3910 3965 4020 1 3 1 2.17 2.30 2.41 2.53 2.68 2.87 3.05 3.23 3.44 3.64 3.85 4.08 4.31 4.56 4.83 5.11 5.40 5.71 6.03 6.38 6.73 7.11 9.15 9.42 9.77 10.08 10.38 10.65 11.00 11.40 11.83 12.36 12.83 13.31 13.80 14.31 14.87 5 2.70 2.85 2.98 3.11 3.27 3.46 3.68 3.89 4.11 4.35 4.59 4.84 5.10 5.37 5.66 5.96 6.28 6.61 6.96 7.33 7.71 8 1/2” RPM BHP 3522 3544 3567 3596 3629 3663 3705 3752 3802 3862 3916 3969 10.08 10.38 10.76 11.08 11.41 11.69 12.07 12.49 12.95 13.52 14.01 14.52 3 3.28 3.44 3.59 3.73 3.91 4.11 4.36 4.60 4.84 5.11 5.37 5.64 5.93 6.23 6.54 6.86 7.21 7.56 7.94 8.33 2564 2587 2614 2647 2684 2729 2786 2839 2892 2946 3001 3058 3115 3174 3234 3294 3356 3419 3483 3.90 4.06 4.25 4.42 4.59 4.81 5.08 5.35 5.61 5.89 6.20 6.50 6.81 7.13 7.47 7.82 8.19 8.57 8.97 Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 3629 3652 3676 3706 3739 3773 3816 3863 3913 3974 11.06 11.38 11.78 12.13 12.47 12.78 13.18 13.63 14.11 14.72 3734 3758 3782 3813 3847 3882 3925 3972 12.08 12.43 12.85 13.22 13.58 13.91 14.34 14.81 3816 3838 3860 3887 3918 3953 12.80 13.14 13.58 13.97 14.35 14.73 0.75 0.81 0.87 0.94 1.03 1.12 1.22 1.32 1.43 1.55 1.68 1.82 1.97 2.13 2.30 2.48 2.68 2.89 3.11 3.35 3.60 3.86 4.14 3916 13.88 3939 14.24 3962 14.72 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 24 0.95 1.02 1.09 1.17 1.27 1.38 1.49 1.61 1.74 1.87 2.01 2.16 2.33 2.51 2.69 2.90 3.11 3.34 3.58 3.83 4.10 4.39 1717 1742 1775 1820 1875 1928 1982 2038 2096 2156 2216 2279 2344 2410 2476 2544 2614 2684 2755 2826 2899 118 126 133 142 1.55 166 1.79 193 2.07 2.21 2.37 2.54 2.72 291 312 3.34 3.57 3.82 4.08 4.35 4.64 Performance Data Q Fan and Super Q II Size 19 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1-3 — Q Fan Size 19” Min - Max Motor HP Class 2 3 - 7.5 — Min - Max Motor HP Class 3 7.5 - 15 7.5 - 15 25 Super Q Fan Size 19” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1-3 3 - 7.5 NA NA Fan Size 21” Wheel Dia. Inlet Area Outlet Area Tip Speed 21.5 inches 3.31 square feet 2.88 square feet 5.63 x RPM ft./minute Performance Data Q Fan and Super Q II Size 21 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 546 mm 0.308 m2 0.268 m2 1.716 m/minute Maximum RPM 2070 2780 3740 Motor 1800 RPM 1200 RPM Minimum Fan RPM 380 253 Table P-3 — Size 21 Q-Fan CFM Std. Air 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 Outlet Vel. 902 972 1041 1111 1180 1250 1319 1388 1458 1527 1597 1666 1736 1805 1875 1944 2013 2083 2152 2222 2291 2361 2430 2500 /4” RPM BHP 810 0.20 859 0.23 909 0.26 959 0.30 1011 0.35 1062 0.40 1115 0.45 1167 0.51 1220 0.58 1273 0.65 1327 0.73 1380 0.81 1434 0.90 1488 1.00 1542 1.11 1596 1.22 1651 1.34 1705 1.47 1759 1.61 1814 1.76 1869 1.91 1923 2.08 1978 2.25 2033 2.44 /8” RPM BHP 859 0.25 903 0.29 949 0.33 996 0.37 1045 0.41 1094 0.47 1145 0.52 1196 0.59 1247 0.65 1299 0.73 1351 0.81 1403 0.90 1456 0.99 1509 1.09 1562 1.20 1616 1.32 1669 1.44 1723 1.57 1777 1.71 1831 1.86 1885 2.02 1939 2.19 1993 2.37 2048 2.56 /2” RPM BHP 908 0.31 949 0.35 991 0.39 1035 0.44 1081 0.48 1128 0.54 1176 0.60 1225 0.66 1274 0.73 1325 0.81 1376 0.89 1427 0.98 1479 1.08 1531 1.18 1583 1.30 1636 1.41 1688 1.54 1741 1.68 1795 1.82 1848 1.97 1902 2.14 1955 2.31 2009 2.49 2063 2.68 /8” RPM BHP 957 0.38 995 0.42 1034 0.46 1075 0.51 1118 0.56 1163 0.61 1208 0.68 1255 0.74 1303 0.82 1352 0.90 1401 0.98 1451 1.07 1502 1.17 1553 1.28 1604 1.39 1656 1.52 1708 1.65 1760 1.78 1813 1.93 1865 2.09 1918 2.25 1971 2.43 2025 2.61 2078 2.80 Total Static Pressure /4” 1” RPM BHP RPM BHP 1001 0.44 1096 0.58 1039 0.48 1121 0.62 1077 0.53 1155 0.67 1116 0.58 1194 0.74 1156 0.64 1231 0.80 1198 0.70 1270 0.86 1242 0.76 1309 0.93 1286 0.83 1350 1.01 1332 0.90 1393 1.09 1379 0.99 1436 1.17 1427 1.07 1481 1.27 1476 1.17 1527 1.37 1525 1.27 1573 1.47 1575 1.38 1621 1.59 1625 1.50 1669 1.71 1676 1.62 1718 1.84 1727 1.75 1768 1.97 1779 1.89 1817 2.12 1831 2.04 1868 2.27 1883 2.20 1919 2.44 1935 2.37 1970 2.61 1988 2.55 2021 2.79 2041 2.73 2073 2.99 2093 2.93 2125 3.19 1 1/4” RPM BHP 1197 0.74 1214 0.79 1236 0.83 1265 0.89 1302 0.96 1339 1.04 1376 1.11 1415 1.20 1454 1.28 1495 1.37 1536 1.47 1580 1.58 1624 1.69 1669 1.80 1715 1.93 1761 2.06 1809 2.21 1857 2.36 1906 2.52 1955 2.68 2005 2.86 2055 3.05 2106 3.25 2156 3.45 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 1308 1323 1344 1369 1401 1440 1477 1515 1553 1593 1633 1675 1718 1762 1806 1852 1898 1945 1993 2041 2090 2139 2189 1411 1426 1445 1469 1499 1537 1573 1610 1648 1687 1727 1767 1809 1852 1895 1940 1986 2031 2078 2125 2173 2222 CFM Std. Air 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 7400 7600 7800 8000 8200 Outlet Vel. 1250 1319 1388 1458 1527 1597 1666 1736 1805 1875 1944 2013 2083 2152 2222 2291 2361 2430 2500 2569 2638 2708 2777 2847 2 1/4” RPM BHP 1615 1.83 1633 1.92 1656 2.01 1682 2.10 1715 2.21 1754 2.35 1791 2.48 1828 2.62 1866 2.77 1904 2.92 1944 3.07 1984 3.23 2026 3.40 2067 3.58 2111 3.77 2154 3.96 2199 4.17 2244 4.38 2290 4.61 2336 4.85 2384 5.09 2431 5.35 2479 5.62 2528 5.90 2 1/2” RPM BHP 1687 2.06 1703 2.14 1721 2.25 1743 2.35 1769 2.44 1801 2.56 1840 2.72 1877 2.86 1914 3.01 1951 3.17 1989 3.34 2029 3.51 2069 3.68 2109 3.87 2151 4.06 2193 4.26 2236 4.47 2281 4.69 2325 4.92 2371 5.16 2416 5.41 2463 5.67 2510 5.95 2558 6.24 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 1852 1868 1887 1910 1935 1966 2001 2042 2078 2116 2153 2192 2231 2272 2312 2354 2396 2439 2483 2528 2573 2619 2007 2023 2043 2067 2092 2124 2158 2199 2236 2273 2311 2349 2388 2428 2468 2509 2550 2593 2636 2680 2137 2153 2170 2192 2215 2243 2275 2310 2351 2388 2425 2462 2500 2539 2579 2619 2659 2701 2742 2394 2410 2428 2449 2471 2499 2529 2563 2604 2641 2678 2715 2752 2790 2829 2868 5.90 6.09 6.31 6.50 6.66 6.88 7.11 7.37 7.70 7.99 8.29 8.59 8.90 9.25 9.58 9.92 2507 6.76 2522 6.96 2539 7.20 2559 7.41 2582 7.62 2606 7.81 2635 8.05 2667 8.33 2702 8.62 2744 8.99 2780 9.31 2817 9.64 2855 9.98 2892 10.32 2930 10.71 2615 2631 2646 2666 2688 2710 2738 2769 2803 2844 2880 2917 2954 2991 CFM Std. Air 6000 6200 6400 6600 6800 7000 7200 7400 7600 7800 8000 8200 8400 8600 8800 9000 Outlet Vel. 2083 2152 2222 2291 2361 2430 2500 2569 2638 2708 2777 2847 2916 2986 3055 3125 7” RPM BHP 2821 9.60 2836 9.84 2851 10.15 2870 10.42 2891 10.68 2914 10.95 2937 11.18 2966 11.49 2997 11.83 3031 12.19 3073 12.66 3110 13.07 3146 13.48 3183 13.90 3220 14.32 3258 14.76 7 1/2” RPM BHP 8” RPM BHP 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 1 3 2919 10.64 2934 10.89 2951 11.16 2967 11.51 2988 11.79 3011 12.08 3033 12.32 3061 12.64 3092 12.99 3125 13.37 3160 13.78 3203 14.30 3239 14.74 1 3015 3030 3046 3063 3083 3105 3127 3154 3184 3217 2.73 2.85 2.97 3.08 3.19 3.34 3.50 3.69 3.87 4.06 4.26 4.46 4.66 4.87 5.09 5.32 5.56 5.81 6.07 6.34 6.63 6.92 11.71 11.98 12.27 12.64 12.95 13.25 13.50 13.84 14.21 14.60 5 3.49 3.64 3.77 3.91 4.04 4.20 4.39 4.62 4.83 5.04 5.26 5.50 5.74 5.98 6.23 6.49 6.76 7.04 7.33 7.64 8 1/2” RPM BHP 3108 3123 3139 3155 3175 3197 3222 12.83 13.11 13.43 13.82 14.15 14.47 14.80 3 4.19 4.33 4.51 4.66 4.80 4.97 5.16 5.38 5.65 5.88 6.12 6.37 6.65 6.91 7.19 7.47 7.76 8.06 8.38 2261 2276 2292 2312 2335 2359 2388 2421 2461 2498 2535 2572 2609 2647 2686 2725 2765 2806 4.94 5.09 5.29 5.46 5.63 5.79 5.99 6.22 6.51 6.77 7.03 7.31 7.59 7.90 8.20 8.50 8.82 9.14 Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 0.96 1.02 1.07 1.13 1.21 1.30 1.39 1.48 1.58 1.69 1.80 1.91 2.03 2.16 2.30 2.45 2.60 2.77 2.94 3.12 3.32 3.52 3.73 3199 13.99 3214 14.29 3230 14.62 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 26 1.20 1.27 1.34 1.40 1.48 1.58 1.68 1.79 1.91 2.02 2.15 2.27 2.41 2.55 2.70 2.86 3.03 3.21 3.39 3.59 3.80 4.01 7.66 7.87 8.14 8.37 8.60 8.79 9.05 9.33 9.64 10.04 10.38 10.74 11.10 11.47 1507 1523 1541 1564 1592 1626 1665 1702 1739 1778 1817 1857 1898 1940 1982 2026 2071 2116 2162 2208 2256 2720 2735 2751 2769 2791 2815 2839 2869 2901 2936 2978 3014 3051 1.46 1.53 1.62 1.69 1.78 1.88 2.01 2.12 2.25 2.38 2.52 2.66 2.81 296 3.13 3.30 3.48 3.67 3.87 4.09 4.31 8.61 8.83 9.12 9.37 9.62 9.87 10.09 10.39 10.71 11.06 11.50 11.88 12.26 Performance Data Q Fan and Super Q II Size 21 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1-5 — Q Fan Size 21” Min - Max Motor HP Class 2 3 - 10 — Min - Max Motor HP Class 3 10 - 15 10 - 15 27 Super Q Fan Size 21” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1-5 3 - 10 NA NA Fan Size 24” Wheel Dia. Inlet Area Outlet Area Tip Speed 24.5 inches 4.32 square feet 3.73 square feet 6.41 x RPM ft./minute Performance Data Q Fan and Super Q II Size 24 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 622 mm 0.401 m2 0.347 m2 1.954 m/minute Maximum RPM 1772 2380 3200 Motor 1800 RPM 1200 RPM Minimum Fan RPM 535 356 Table P-4 — Size 24 Q-Fan CFM Std. •Air 3000 3400 3800 4200 4600 5000 5400 5800 6200 6600 7000 7400 7800 8200 8600 9000 9400 9800 10200 10600 11000 11400 11800 12200 Outlet Vel. 804 911 1018 1126 1233 1340 1447 1554 1662 1769 1876 1983 2091 2198 2305 2412 2520 2627 2734 2841 2949 3056 3163 3270 /4” RPM BHP 639 0.2 703 0.3 769 0.3 836 0.4 905 0.5 974 0.6 1044 0.7 1114 0.9 1185 1.0 1256 1.2 1328 1.4 1399 1.7 1471 1.9 1544 2.2 1616 2.5 1688 2.8 1761 3.2 1833 3.6 1906 4.0 1979 4.5 2052 5.0 2125 5.6 2198 6.1 2271 6.7 /8” RPM BHP 685 0.3 741 0.3 803 0.4 867 0.5 933 0.6 1000 0.7 1068 0.8 1137 1.0 1206 1.2 1276 1.3 1346 1.6 1417 1.8 1488 2.1 1559 2.3 1631 2.7 1703 3.0 1775 3.4 1847 3.8 1919 4.2 1991 4.7 2064 5.2 2136 5.7 2209 6.3 2281 7.0 /2” RPM BHP 730 0.3 782 0.4 837 0.5 897 0.6 961 0.7 1026 0.8 1092 0.9 1159 1.1 1227 1.3 1296 1.5 1365 1.7 1434 1.9 1505 2.2 1575 2.5 1646 2.8 1717 3.2 1788 3.5 1860 4.0 1932 4.4 2003 4.9 2075 5.4 2147 5.9 2220 6.5 2292 7.2 /8” RPM BHP 773 0.4 822 0.5 874 0.6 929 0.7 989 0.8 1052 0.9 1116 1.0 1181 1.2 1248 1.4 1315 1.6 1383 1.8 1452 2.1 1521 2.3 1591 2.6 1661 3.0 1731 3.3 1802 3.7 1873 4.1 1944 4.6 2016 5.1 2087 5.6 2159 6.1 2231 6.7 2303 7.4 Total Static Pressure /4” 1” RPM BHP RPM BHP 817 0.5 908 0.7 861 0.6 937 0.7 910 0.7 978 0.8 962 0.8 1027 1.0 1018 0.9 1078 1.1 1077 1.0 1132 1.2 1139 1.2 1188 1.4 1204 1.3 1248 1.6 1269 1.5 1310 1.8 1335 1.7 1374 2.0 1402 1.9 1439 2.2 1470 2.2 1505 2.5 1538 2.5 1571 2.8 1607 2.8 1639 3.1 1676 3.1 1706 3.4 1746 3.5 1775 3.8 1816 3.9 1844 4.2 1886 4.3 1913 4.7 1957 4.8 1982 5.1 2028 5.2 2052 5.6 2099 5.8 2122 6.2 2170 6.3 2193 6.7 2242 6.9 2264 7.4 2313 7.6 2334 8.0 CFM Std. Air 5000 5400 5800 6200 6600 7000 7400 7800 8200 8600 9000 9400 9800 10200 10600 11000 11400 11800 12200 12600 13000 13400 13800 14200 Outlet Vel. 1340 1447 1554 1662 1769 1876 1983 2091 2198 2305 2412 2520 2627 2734 2841 2949 3056 3163 3270 3378 3485 3592 3699 3806 2 1/4” RPM BHP 1397 2.5 1435 2.7 1479 2.9 1528 3.1 1578 3.4 1630 3.7 1684 4.0 1740 4.4 1797 4.7 1856 5.1 1918 5.6 1980 6.0 2045 6.6 2110 7.1 2175 7.6 2241 8.2 2307 8.9 2374 9.6 2441 10.3 2509 11.0 2577 11.8 2645 12.7 2714 13.5 2783 14.5 2 1/2” RPM BHP 1451 2.8 1484 3.0 1524 3.2 1571 3.4 1619 3.7 1669 4.0 1721 4.3 1775 4.7 1831 5.1 1887 5.5 1947 5.9 2008 6.4 2070 6.9 2135 7.5 2199 8.1 2264 8.7 2330 9.3 2396 10.0 2462 10.7 2529 11.5 2597 12.3 2664 13.2 2733 14.1 2801 15.0 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 1585 1615 1654 1697 1745 1794 1845 1898 1952 2008 2064 2124 2185 2247 2311 2375 2440 2505 2571 2637 2703 2770 2838 3.6 3.8 4.1 4.4 4.7 5.0 5.4 5.8 6.2 6.7 7.2 7.7 8.3 8.9 9.6 10.2 10.9 11.7 12.5 13.3 14.2 15.1 16.1 1710 1739 1776 1818 1866 1914 1964 2016 2069 2124 2179 2237 2296 2357 2419 2483 2547 2612 2677 2742 2808 2874 1806 1828 1857 1894 1935 1980 2029 2079 2130 2182 2236 2292 2347 2405 2465 2526 2588 2651 2716 2781 2845 2911 2025 2048 2078 2114 2155 2200 2249 2297 2347 2399 2452 2506 2562 2617 2675 2734 2795 2856 2919 2984 2128 2152 2182 2220 2260 2305 2354 2402 2452 2503 2556 2610 2665 2721 2777 2835 2895 2956 3018 2227 2252 2284 2322 2363 2407 2456 2505 2554 2606 2658 2711 2766 2822 2877 2935 2995 3055 CFM Std. Air 8600 9000 9400 9800 10200 10600 11000 11400 11800 12200 12600 13000 13400 13800 14200 14600 Outlet Vel. 2305 2412 2520 2627 2734 2841 2949 3056 3163 3270 3378 3485 3592 3699 3806 3914 7” RPM 2446 2480 2519 2561 2605 2655 2703 2753 2804 2856 2909 2963 3018 3073 3130 3189 7 1/2” RPM BHP 2510 14.3 2539 14.8 2574 15.4 2614 16.1 2657 16.8 2702 17.6 2752 18.5 2800 19.3 2849 20.2 2900 21.1 2952 22.0 3005 23.0 3059 24.1 3115 25.2 3171 26.4 8” RPM 2575 2600 2631 2667 2708 2751 2796 2846 2895 2945 2995 3047 3100 3154 BHP 15.3 15.9 16.5 17.2 17.9 18.6 19.5 20.4 21.3 22.2 23.2 24.2 25.3 26.4 8 1/2” RPM BHP 2640 16.4 2662 16.9 2689 17.6 2722 18.3 2760 19.0 2800 19.7 2844 20.6 2890 21.5 2940 22.5 2989 23.4 3038 24.4 3089 25.5 3141 26.5 3194 27.7 1 BHP 13.2 13.8 14.4 15.1 15.8 16.6 17.4 18.2 19.0 19.9 20.9 21.9 22.9 24.1 25.2 26.4 3 1 5 4.5 4.8 5.1 5.4 5.8 6.2 6.6 7.0 7.5 8.0 8.6 9.2 9.8 10.4 11.1 11.9 12.7 13.5 14.3 15.2 16.2 17.2 3 5.2 5.5 5.8 6.1 6.5 6.9 7.4 7.8 8.3 8.8 9.4 10.0 10.7 11.3 12.1 12.8 13.6 14.5 15.4 16.3 17.3 18.3 1918 1940 1969 2006 2047 2091 2141 2190 2240 2292 2345 2400 2456 2512 2571 2631 2692 2754 2819 2883 2947 6.3 6.6 6.9 7.3 7.7 8.1 8.7 9.2 9.7 10.3 10.9 11.6 12.3 13.0 13.8 14.6 15.5 16.4 17.4 18.4 19.4 Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 2724 2748 2777 2811 2850 2891 2935 2984 3032 3081 3131 3182 18.0 18.7 19.4 20.1 20.9 21.7 22.6 23.6 24.6 25.7 26.7 27.8 2787 2808 2833 2864 2899 2939 2981 3026 3075 3123 3172 19.2 19.8 20.5 21.3 22.0 22.9 23.8 24.7 25.8 26.9 28.0 1 1/4” RPM BHP 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 1018 1048 1088 1136 1186 1239 1295 1352 1413 1475 1540 1605 1670 1737 1804 1871 1939 2008 2077 2146 2216 2286 2356 1120 1151 1192 1240 1290 1342 1397 1453 1512 1574 1638 1702 1767 1833 1899 1966 2033 2101 2170 2238 2308 2377 1215 1249 1291 1340 1389 1441 1495 1551 1609 1670 1732 1797 1861 1927 1992 2059 2126 2193 2261 2330 2398 0.9 1.0 1.2 1.3 1.4 1.6 1.8 2.0 2.2 2.5 2.8 3.1 3.4 3.8 4.2 4.6 5.0 5.5 6.0 6.6 7.2 7.8 8.4 7.4 7.7 8.1 8.5 9.0 9.5 10.1 10.6 11.2 11.9 12.5 13.2 14.0 14.8 15.6 16.5 17.5 18.4 19.5 20.6 1.3 1.4 1.5 1.7 1.9 2.1 2.3 2.5 2.8 3.1 3.4 3.7 4.1 4.5 4.9 5.4 5.9 6.4 7.0 7.6 8.2 8.9 8.6 9.0 9.4 9.9 10.4 10.9 11.6 12.2 12.8 13.5 14.2 15.0 15.8 16.6 17.6 18.5 19.5 20.6 21.7 1.6 1.8 1.9 2.1 2.3 2.5 2.8 3.1 3.4 3.7 4.1 4.5 4.9 5.3 5.8 6.3 6.8 7.4 8.0 8.7 9.3 9.9 10.3 10.8 11.3 11.8 12.4 13.1 13.8 14.5 15.2 16.0 16.8 17.7 18.6 19.6 20.7 21.7 22.8 1282 1308 1344 1387 1435 1485 1537 1591 1646 1704 1764 1826 1890 1954 2019 2084 2150 2217 2284 2352 2420 2303 2324 2350 2383 2421 2463 2507 2557 2605 2655 2705 2758 2811 2865 2921 2976 3033 3092 1.9 2.0 2.2 2.4 2.6 2.8 3.1 3.4 3.7 4.0 4.4 4.8 5.2 5.7 6.2 6.7 7.2 7.8 8.4 9.1 9.8 10.8 11.2 11.7 12.2 12.8 13.4 14.1 14.8 15.5 16.3 17.1 17.9 18.8 19.7 20.7 21.8 22.9 24.0 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 2867 2890 2917 2950 2986 3027 3070 3115 3165 2927 2947 2971 3001 3035 3074 3114 3158 3004 3026 3052 3084 3119 3159 21.0 21.6 22.5 23.2 24.1 25.0 25.9 26.9 28.1 22.2 22.9 23.7 24.5 25.3 26.2 27.2 28.2 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 28 24.1 24.8 25.7 26.6 27.4 28.4 3081 3104 3133 3166 26.1 27.0 27.8 28.7 Performance Data Q Fan and Super Q II Size 24 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1-5 — Q Fan Size 24” Min - Max Motor HP Class 2 5 - 15 — Min - Max Motor HP Class 3 15-30 15 - 30 29 Super Q Fan Size 24” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1-5 5 - 10 NA NA Fan Size 27” Wheel Dia. Inlet Area Outlet Area Tip Speed 27.0 inches 5.20 square feet 4.54 square feet 7.07 x RPM ft./minute Performance Data Q Fan and Super Q II Size 27 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 686 mm 0.483 m2 0.422 m2 2.155 m/minute Maximum RPM 1610 2160 2908 Motor 1800 RPM 1200 RPM Minimum Fan RPM 437 291 Table P-5 — Size 27 Q-Fan CFM Std. Air 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000 9500 10000 10500 11000 11500 12000 12500 13000 13500 14000 14500 Outlet Vel. 660 770 881 991 1101 1211 1321 1431 1541 1651 1762 1872 1982 2092 2202 2312 2422 2533 2643 2753 2863 2973 3083 3193 /4” RPM BHP 510 0.2 564 0.2 623 0.3 684 0.4 746 0.5 810 0.6 874 0.7 939 0.9 1005 1.1 1071 1.3 1138 1.5 1205 1.7 1272 2.0 1339 2.4 1406 2.7 1474 3.1 1541 3.5 1609 4.0 1677 4.5 1745 5.0 1813 5.6 1881 6.3 1949 7.0 2017 7.7 /8” RPM BHP 559 0.3 607 0.3 658 0.4 715 0.5 775 0.6 836 0.7 898 0.8 961 1.0 1026 1.2 1090 1.4 1156 1.6 1221 1.9 1287 2.2 1354 2.5 1420 2.9 1487 3.3 1554 3.7 1622 4.2 1689 4.7 1756 5.3 1824 5.9 1892 6.5 1959 7.2 2027 7.9 /2” RPM BHP 607 0.3 649 0.4 697 0.5 747 0.6 803 0.7 862 0.8 922 1.0 983 1.1 1046 1.3 1109 1.5 1174 1.8 1238 2.0 1303 2.4 1369 2.7 1435 3.1 1501 3.5 1567 3.9 1634 4.4 1701 4.9 1768 5.5 1835 6.1 1902 6.7 1969 7.4 2037 8.2 RPM 657 690 734 781 832 887 945 1005 1067 1129 1191 1255 1319 1384 1449 1515 1580 1646 1713 1779 1846 1913 1980 2047 CFM Std. Air 6000 6500 7000 7500 8000 8500 9000 9500 10000 10500 11000 11500 12000 12500 13000 13500 14000 14500 15000 15500 16000 16500 17000 17500 Outlet Vel. 1321 1431 1541 1651 1762 1872 1982 2092 2202 2312 2422 2533 2643 2753 2863 2973 3083 3193 3303 3414 3524 3634 3744 3854 2 1/4” RPM BHP 1263 3.0 1298 3.2 1338 3.5 1384 3.8 1430 4.1 1479 4.5 1529 4.9 1581 5.3 1635 5.8 1691 6.3 1748 6.9 1808 7.5 1868 8.1 1928 8.8 1989 9.5 2051 10.2 2113 11.0 2175 11.9 2238 12.8 2301 13.8 2365 14.8 2429 15.9 2493 17.0 2558 18.2 2 1/2” RPM BHP 1313 3.3 1342 3.6 1380 3.8 1421 4.1 1467 4.5 1514 4.9 1563 5.3 1613 5.7 1665 6.2 1719 6.7 1774 7.3 1832 7.9 1890 8.5 1951 9.3 2011 10.0 2072 10.8 2133 116 2195 12.5 2257 13.4 2320 14.4 2383 15.4 2446 16.5 2510 17.6 2574 18.9 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 1435 1463 1498 1538 1584 1629 1677 1726 1777 1828 1882 1938 1995 2053 2114 2174 2234 2295 2357 2419 2481 2544 2607 1549 1576 1611 1650 1694 1739 1786 1835 1885 1936 1988 2042 2098 2155 2213 2274 2333 2394 2455 2516 2578 2640 1657 1684 1718 1757 1799 1845 1891 1939 1989 2039 2091 2143 2198 2254 2312 2370 2430 2490 2550 2611 2672 1837 1858 1886 1921 1959 2001 2047 2092 2139 2188 2238 2289 2341 2393 2447 2503 2560 2618 2677 2738 1931 1953 1982 2017 2056 2097 2143 2189 2236 2284 2333 2384 2436 2487 2541 2596 2653 2710 2768 2021 2045 2075 2111 2150 2191 2238 2283 2330 2378 2427 2477 2529 2580 2633 2688 2744 2801 CFM Std. Air 10000 10500 11000 11500 12000 12500 13000 13500 14000 14500 15000 15500 16000 16500 17000 17500 Outlet Vel. 2202 2312 2422 2533 2643 2753 2863 2973 3083 3193 3303 3414 3524 3634 3744 3854 7” RPM 2196 2223 2255 2292 2331 2374 2420 2466 2513 2561 2609 2659 2711 2763 2814 2868 7 1/2” RPM BHP 2258 16.7 2280 17.4 2309 18.1 2342 18.9 2380 19.7 2420 20.6 2463 21.6 2509 22.7 2555 23.8 2602 24.9 2650 26.0 2698 27.2 2748 28.5 2799 29.9 2851 31.3 2902 32.9 8” RPM 2319 2339 2363 2393 2428 2466 2507 2552 2597 2642 2689 2737 2786 2836 2887 1 BHP 15.4 16.2 16.9 17.6 18.5 19.3 20.4 21.4 22.4 23.5 24.6 25.8 27.1 28.4 29.9 31.4 3 1 4.3 4.6 4.9 5.3 5.7 6.1 6.6 7.1 7.6 8.2 8.9 9.5 10.2 11.0 11.8 12.7 13.6 14.6 15.6 16.6 17.8 18.9 20.2 BHP 18.0 18.6 19.4 20.2 21.0 21.9 22.9 24.0 25.1 26.3 27.5 28.7 30.0 31.4 32.8 5/ ” 8 BHP 0.4 0.5 0.6 0.7 0.8 0.9 1.1 1.2 1.4 1.7 1.9 2.2 2.5 2.9 3.2 3.6 4.1 4.6 5.1 5.7 6.3 7.0 7.7 8.4 5.4 5.8 6.1 6.5 7.0 7.5 3.0 8.6 9.2 9.8 10.5 11.3 12.1 12.9 13.8 14.8 15.8 16.6 17.9 19.0 20.3 21.5 8 1/2” RPM BHP 2398 2419 2445 2476 2513 2551 2592 2638 2683 2729 2776 2824 2873 Total Static Pressure /4” 1” RPM BHP RPM BHP 1 1/4” RPM BHP 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 731 769 815 863 914 969 1027 1087 1148 1209 1272 1335 1399 1463 1528 1593 1659 1725 1791 1857 1923 1990 2057 918 943 979 1023 1070 1119 1170 1224 1280 1338 1399 1459 1521 1583 1645 1709 1772 1836 1901 1966 2031 2096 1011 1038 1075 1119 1165 1214 1264 1317 1372 1430 1489 1549 1610 1671 1734 1796 1859 1923 1987 2051 2116 1098 1127 1166 1210 1256 1305 1355 1407 1462 1518 1577 1637 1697 1758 1820 1882 1945 2008 2072 2136 3 19.9 20.6 21.5 22.3 23.3 24.2 25.3 26.5 27.7 28.9 30.2 31.5 32.9 0.6 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.8 2.1 2.4 2.7 3.0 3.4 3.8 4.3 4.8 5.3 5.9 6.5 7.2 7.9 8.7 6.6 7.0 7.4 7.9 8.4 9.0 9.6 10.2 10.9 11.6 12.3 13.2 14.0 14.9 15.9 16.9 18.0 19.2 20.3 21.6 22.9 842 878 923 970 1020 1072 1127 1185 1245 1306 1367 1429 1492 1555 1619 1684 1748 1813 1879 1944 2010 2076 1740 1760 1787 1821 1859 1901 1948 1993 2041 2090 2140 2191 2242 2296 2352 2408 2466 2524 2585 2645 2705 0.9 1.0 1.1 1.3 1.4 1.6 1.9 2.1 2.4 2.7 3.0 3.4 3.8 4.2 4.7 5.2 5.8 6.4 7.0 7.7 8.4 9.2 7.6 7.9 8.4 8.9 9.4 9.9 10.6 11.2 11.9 12.7 13.4 14.3 15.2 16.1 17.1 18.1 19.2 20.4 21.7 22.9 24.3 Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 2475 2498 2526 2558 2596 2635 2677 2723 2768 2814 2861 22.0 22.9 23.7 24.6 25.6 26.7 27.8 29.1 30.4 31.7 33.0 2531 2551 2576 2606 2640 2678 2718 2760 2807 2852 2898 23.4 24.2 25.1 26.0 27.0 28.1 29.2 30.4 31.9 33.2 34.6 1.1 1.2 1.4 1.5 1.7 1.9 2.2 2.4 2.7 3.0 3.4 3.8 4.2 4.6 5.1 5.6 6.2 6.8 7.5 8.2 8.9 9.7 9.0 9.4 9.9 10.4 11.0 11.6 12.3 13.0 13.8 14.6 15.4 16.3 17.3 18.3 19.4 20.5 21.7 23.0 24.3 25.7 1.5 1.6 1.8 2.0 2.2 2.5 2.7 3.0 3.4 3.7 4.1 4.6 5.0 5.5 6.1 6.7 7.3 8.0 8.7 9.4 10.3 10.4 10.9 11.5 12.0 12.7 13.4 14.2 14.9 15.8 16.6 17.5 18.5 19.5 20.7 21.8 23.0 24.3 25.6 27.0 1.9 2.1 2.3 2.5 2.8 3.1 3.4 3.7 4.1 4.5 5.0 5.5 6.0 6.5 7.1 7.8 8.5 9.2 10.0 10.8 12.0 12.6 13.2 13.8 14.5 15.2 16.1 17.0 17.9 18.8 19.8 20.8 21.9 23.1 24.4 25.7 27.0 28.5 1160 1182 1214 1253 1298 1345 1393 1443 1495 1549 1605 1663 1723 1783 1844 1905 1967 2029 2092 2155 2090 2110 2135 2166 2202 2241 2284 2330 2375 2422 2470 2519 2569 2620 2673 2724 2779 2835 2.2 2.4 2.6 2.9 3.1 3.4 3.7 4.1 4.5 4.9 5.4 5.9 6.4 7.0 7.6 8.3 9.0 9.7 10.5 11.3 13.2 13.7 14.3 14.9 15.7 16.4 17.2 18.2 19.1 20.1 21.1 22.1 23.3 24.4 25.7 27.1 28.5 29.9 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 2605 2627 2654 2685 2721 2759 2800 2842 2890 2659 2678 2702 2731 2763 2801 2839 2881 2730 2751 2777 2807 2841 2879 25.6 26.6 27.5 28.5 29.5 30.7 31.9 33.2 34.7 27.1 27.9 29.0 30.0 31.0 32.2 33.4 34.7 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 30 29.4 30.4 31.5 32.6 33.7 34.9 2781 2800 2823 2851 2883 31.0 31.9 33.0 34.1 35.3 Performance Data Q Fan and Super Q II Size 27 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1 - 7.5 — Q Fan Size 27” Min - Max Motor HP Class 2 5 -15 5 -15 Min - Max Motor HP Class 3 15 - 40 15 - 40 31 Super Q Fan Size 27” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1 - 7.5 5-15 NA NA Fan Size 30” Wheel Dia. Inlet Area Outlet Area Tip Speed 30.0 inches 6.45 square feet 5.60 square feet 7.85 x RPM ft./minute Performance Data Q Fan and Super Q II Size 30 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 762 mm 0.599 m2 0.520 m2 2.393 m/minute Maximum RPM 1448 1940 2618 Motor 1800 RPM 1200 RPM Minimum Fan RPM 365 243 Table P-6 — Size 30 Q-Fan CFM Std. Air 5000 5500 6000 6500 7000 7500 8000 8500 9000 9500 10000 10500 11000 11500 12000 12500 13000 13500 14000 14500 15000 15500 16000 16500 Outlet Vel. 892 982 1071 1160 1250 1339 1428 1517 1607 1696 1785 1874 1964 2053 2142 2232 2321 2410 2500 2589 2678 2767 2857 2946 /4” RPM BHP 566 0.4 610 0.5 656 0.6 702 0.7 748 0.8 796 0.9 843 1.1 891 1.2 939 1.4 987 1.7 1036 1.9 1085 2.2 1134 2.4 1183 2.8 1232 3.1 1281 3.5 1330 3.8 1379 4.3 1429 4.7 1478 5.2 1528 5.7 1577 6.3 1627 6.9 1676 7.5 /8” RPM BHP 597 0.5 639 0.6 682 0.7 726 0.8 771 0.9 817 1.1 863 1.2 910 1.4 957 1.6 1004 1.8 1052 2.1 1100 2.3 1148 2.6 1196 3.0 1245 3.3 1293 3.7 1342 4.1 1391 4.5 1440 5.0 1489 5.5 1538 6.0 1587 6.6 1637 7.2 1686 7.8 /2” RPM BHP 631 0.6 669 0.7 708 0.8 750 0.9 794 1.1 838 1.2 883 1.4 928 1.6 974 1.8 1021 2.0 1068 2.3 1115 2.5 1162 2.8 1210 3.2 1258 3.5 1306 3.9 1354 4.3 1403 4.7 1451 5.2 1500 5.7 1549 6.3 1598 6.8 1647 7.4 1696 8.1 /8” RPM BHP 664 0.7 699 0.8 736 0.9 775 1.0 816 1.2 859 1.4 903 1.5 947 1.7 992 1.9 1038 2.2 1084 2.4 1130 2.7 1177 3.0 1224 3.4 1271 3.7 1319 4.1 1367 4.5 1415 5.0 1463 5.5 1511 6.0 1559 6.5 1608 7.1 1656 7.7 1705 8.4 Total Static Pressure /4” 1” RPM BHP RPM BHP 696 0.8 761 1.1 729 0.9 787 1.2 764 1.1 819 1.3 801 1.2 852 1.5 839 1.3 888 1.6 880 1.5 925 1.8 922 1.7 963 2.0 966 1.9 1003 2.2 1010 2.1 1044 2.5 1054 2.4 1088 2.7 1100 2.6 1131 3.0 1145 2.9 1176 3.3 1191 3.2 1220 3.7 1238 3.6 1266 4.0 1285 4.0 1311 4.4 1332 4.3 1357 4.8 1379 4.8 1403 5.3 1426 5.2 1450 5.7 1474 5.7 1497 6.2 1522 6.2 1544 6.8 1570 6.8 1591 7.3 1618 7.4 1639 7.9 1666 8.0 1686 8.6 1715 8.7 1734 9.3 1 1/4” RPM BHP 828 1.4 846 1.5 872 1.6 901 1.8 935 2.0 969 2.2 1005 2.4 1042 2.6 1081 2.9 1121 3.1 1162 3.4 1205 3.7 1249 4.1 1293 4.5 1338 4.9 1383 5.3 1428 5.8 1474 6.2 1520 6.8 1566 7.3 1612 7.9 1659 8.5 1706 9.2 1753 9.9 1 1/2” RPM BHP RPM 2” BHP RPM BHP 908 926 951 980 1013 1047 1082 1118 1156 1195 1235 1277 1320 1364 1408 1452 1497 1542 1588 1634 1680 1726 1773 983 1001 1026 1055 1088 1121 1156 1192 1229 1267 1307 1348 1390 1433 1477 1521 1565 1610 1655 1700 1746 1792 2.3 2.5 2.7 2.9 3.1 3.4 3.7 3.9 4.3 4.6 5.0 5.4 5.8 6.3 6.8 7.3 7.8 8.4 9.0 9.7 10.4 11.1 CFM Std. Air 8000 8500 9000 9500 10000 10500 11000 11500 12000 12500 13000 13500 14000 14500 15000 15500 16000 16500 17000 17500 18000 18500 19000 19500 Outlet Vel. 1428 1517 1607 1696 1785 1874 1964 2053 2142 2232 2321 2410 2500 2585 2678 2767 2857 2946 3035 3125 3214 3303 3392 3482 2 1/4” RPM BHP 1167 3.9 1196 4.2 1229 4.5 1262 4.8 1296 5.2 1332 5.5 1368 5.9 1406 6.4 1444 6.8 1484 7.3 1525 7.8 1567 8.4 1609 8.9 1653 9.6 1697 10.2 1741 10.9 1786 11.6 1830 12.4 1876 13.2 1921 14.0 1967 14.9 2013 15.8 2059 16.7 2105 17.7 2 1/2” RPM BHP 1207 4.4 1234 4.7 1263 5.0 1296 5.3 1329 5.7 1363 6.0 1399 6.4 1435 6.9 1473 7.3 1510 7.8 1550 8.4 1590 8.9 1632 9.5 1674 10.1 1718 10.8 1762 11.5 1806 12.3 1850 13.0 1894 13.8 1939 14.7 1984 15.6 2030 16.5 2075 17.5 2121 18.5 3” RPM 1291 1310 1334 1362 1392 1426 1459 1493 1529 1565 1602 1640 1678 1719 1760 1801 1844 1888 1932 1975 2020 2064 2109 2154 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 1390 1407 1430 1456 1485 1518 1550 1584 1618 1654 1690 1727 1765 1803 1843 1884 1925 1968 2010 2055 2098 2142 2187 1483 1500 1521 1547 1574 1605 1638 1671 1705 1740 1775 1812 1849 1887 1925 1965 2005 2047 2089 2131 2176 2219 1657 1672 1692 1716 1743 1772 1803 1837 1870 1904 1939 1974 2010 2047 2085 2122 2161 2201 2242 2283 1738 1754 1773 1797 1824 1852 1882 1916 1949 1982 2017 2052 2088 2124 2162 2200 2237 2276 2316 1816 1832 1852 1875 1902 1930 1960 1994 2026 2059 2093 2128 2164 2200 2237 2275 2313 2350 CFM Std. Air 13000 13500 14000 14500 15000 15500 16000 16500 17000 17500 18000 18500 19000 19500 20000 20500 Outlet Vel. 2321 2410 2500 2589 2678 2767 2857 2946 3035 3125 3214 3303 3392 3482 3571 3660 7” RPM 2002 2025 2052 2080 2109 2141 2175 2208 2242 2276 231 2347 2384 2421 2458 2496 7 1/2” RPM BHP 2054 21.5 2074 22.2 2098 23.0 2124 23.8 2152 24.7 2182 25.6 2213 26.5 2248 27.7 2280 28.7 2314 29.8 2348 30.9 2383 32.1 2419 33.3 2455 34.6 2492 35.9 2529 37.2 8” RPM 2106 2124 2145 2168 2195 2223 2253 2284 2319 2351 2385 2419 2454 2489 2525 2562 1 BHP 20.0 20.7 21.5 22.2 23.1 24.0 25.1 26.1 27.1 28.1 29.2 30.4 31.6 32.8 34.1 35.5 3 1 BHP 5.3 5.6 5.9 6.2 6.6 7.1 7.5 7.9 8.4 8.9 9.5 10.0 10.7 11.3 12.0 12.7 13.5 14.3 15.2 16.1 17.0 17.9 18.9 20.0 BHP 23.0 23.8 24.6 25.4 26.3 27.2 28.2 29.2 30.4 31.5 32.7 33.9 35.1 36.4 37.7 39.1 5 6.6 6.9 7.3 7.7 8.1 8.6 9.0 9.6 10.1 10.6 11.2 11.9 12.5 13.3 14.0 14.8 15.7 16.5 17.4 18.4 19.4 20.4 21.5 8 1/2” RPM BHP 2159 24.7 2174 25.4 2192 26.2 2214 27.0 2238 27.9 2265 28.8 2293 29.8 2323 30.9 2354 32.0 2388 33.2 2421 34.4 2455 35.6 2489 36.9 2523 38.2 2559 39.5 2595 40.9 3 8.0 8.4 8.8 9.2 9.6 10.1 10.7 11.3 11.9 12.5 13.1 13.8 14.6 15.3 16.2 17.0 17.9 18.9 19.8 20.9 22.0 23.1 1572 1588 1609 1633 1660 1690 1723 1755 1789 1823 1858 1894 1931 1968 2006 2044 2084 2125 2166 2208 2250 9.5 9.9 10.4 10.8 11.3 11.9 12.5 13.1 13.8 14.5 15.2 15.9 16.7 17.5 18.4 19.3 20.3 21.3 22.4 23.5 24.6 Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 2225 2241 2260 2282 2306 2333 2362 2391 2423 2457 2490 2523 2557 2592 27.0 27.8 28.7 29.6 30.5 31.5 32.6 33.7 34.8 36.2 37.5 38.7 40.1 41.4 2276 2290 2306 2326 2348 2373 2401 2429 2459 2490 2525 2558 2591 28.8 29.5 30.5 31.3 32.3 33.3 34.3 35.4 36.6 37.8 39.3 40.6 42.0 11.1 11.6 12.1 12.6 13.1 13.7 14.4 15.1 15.8 16.5 17.3 18.1 18.9 19.8 20.8 21.8 22.8 23.9 25.0 26.2 1.8 2.0 2.1 2.3 2.5 2.7 3.0 3.2 3.5 3.8 4.2 4.5 4.9 5.3 5.8 6.3 6.8 7.3 7.9 8.5 9.1 9.8 10.5 12.9 13.4 13.9 14.5 15.0 15.7 16.4 17.2 18.0 18.7 19.6 20.4 21.3 22.3 23.3 24.3 25.5 26.6 27.8 1 3/ 4 ” 14.7 15.3 15.8 16.4 17.1 17.8 18.5 19.4 20.2 21.1 22.0 22.9 23.8 24.9 25.9 27.0 28.2 29.5 1053 1072 1098 1126 1159 1192 1227 1263 1300 1338 1376 1416 1458 1500 1544 1588 1632 1676 1721 1766 1811 1892 1908 1928 1951 1978 2006 2036 2069 2101 2135 2168 2203 2238 2274 2311 2348 2386 2.9 3.1 3.3 3.5 3.8 4.1 4.4 4.7 5.1 5.4 5.9 6.3 6.8 7.3 7.8 8.4 9.0 9.6 10.3 11.0 11.7 16.6 17.2 17.9 18.5 19.2 20.0 20.7 21.7 22.6 23.5 24.5 25.4 26.5 27.5 28.7 29.8 31.1 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 2339 2354 2371 2391 2414 2440 2467 2496 2526 2557 2592 2401 2416 2434 2455 2479 2505 2533 2561 2592 2448 2462 2478 2497 2519 2543 2569 2597 31.3 32.1 33.1 34.1 35.1 36.1 37.2 38.4 39.6 40.9 42.5 33.9 34.8 35.9 36.9 37.9 39.1 40.2 41.5 42.8 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 32 35.8 36.7 37.6 38.8 39.8 40.9 42.1 43.4 2508 2522 2539 2559 2581 2606 38.6 39.5 40.7 41.7 42.9 44.1 Performance Data Q Fan and Super Q II Size 30 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1 - 7.5 — Q Fan Size 30” Min - Max Motor HP Class 2 7.5 - 20 7.5 - 20 Min - Max Motor HP Class 3 15 - 50 15 - 50 33 Super Q Fan Size 30” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1 - 7.5 7.5 - 20 NA NA Fan Size 33” Wheel Dia. Inlet Area Outlet Area Tip Speed 33.0 inches 7.78 square feet 6.78 square feet 8.64 x RPM ft./minute Performance Data Q Fan and Super Q II Size 33 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 838 mm 0.723 m2 0.630 m2 2.633 m/minute Maximum RPM 1358 1822 2455 Motor 1800 RPM 1200 RPM Minimum Fan RPM 490 326 Table P-7 — Size 33 Q-Fan CFM Std. Air 6000 6600 7200 7800 8400 9000 9600 10200 10800 11400 12000 12600 13200 13800 14400 15000 15600 16200 16800 17400 18000 18600 19200 19800 Outlet Vel. 884 973 1061 1150 1238 1327 1415 1504 1592 1681 1769 1858 1946 2035 2123 2212 2300 2389 2477 2566 2654 2743 2831 2920 /4” RPM BHP 521 0.4 560 0.5 601 0.6 643 0.7 686 0.8 729 1.0 772 1.2 816 1.3 860 1.6 904 1.8 948 2.0 993 2.3 1038 2.6 1083 3.0 1128 3.3 1173 3.7 1218 4.2 1263 4.6 1308 5.1 1353 5.6 1399 6.2 1444 6.8 1490 7.5 1535 8.1 /8” RPM BHP 554 0.6 590 0.6 628 0.7 667 0.9 708 1.0 749 1.2 791 1.3 833 1.5 876 1.7 920 2.0 963 2.2 1007 2.5 1051 2.8 1095 3.2 1140 3.6 1184 4.0 1229 4.4 1274 4.9 1318 5.4 1363 5.9 1408 6.5 1453 7.1 1498 7.7 1544 8.4 /2” RPM BHP 588 0.7 621 0.8 656 0.9 693 1.0 731 1.2 770 1.3 810 1.5 851 1.7 893 1.9 935 2.2 978 2.4 1021 2.7 1064 3.1 1108 3.4 1152 3.8 1196 4.2 1240 4.7 1284 5.1 1329 5.6 1373 6.2 1418 6.8 1463 7.4 1507 8.0 1552 8.7 /8” RPM BHP 620 0.8 652 0.9 684 1.1 719 1.2 755 1.4 792 1.5 830 1.7 870 1.9 910 2.1 952 2.4 993 2.7 1036 3.0 1078 3.3 1121 3.7 1164 4.0 1208 4.5 1251 4.9 1295 5.4 1339 5.9 1383 6.5 1428 7.1 1472 7.7 1516 8.3 1561 9.1 Total Static Pressure /4” 1” RPM BHP RPM BHP 651 1.0 713 1.3 681 1.1 737 1.4 712 1.2 764 1.6 745 1.4 795 1.7 779 1.5 827 1.9 814 1.7 860 2.1 851 1.9 893 2.3 889 2.1 929 2.6 928 2.3 965 2.8 968 2.6 1003 3.1 1009 2.9 1041 3.4 1050 3.2 1080 3.7 1092 3.5 1120 4.0 1134 3.9 1161 4.4 1177 4.3 1202 4.8 1220 4.7 1244 5.2 1263 5.2 1286 5.7 1306 5.7 1328 6.2 1350 6.2 1371 6.8 1393 6.7 1414 7.3 1437 7.3 1457 7.9 1481 8.0 1500 8.6 1526 8.7 1544 9.3 1570 9.4 1588 10.0 CFM Std. Air 9000 9600 10200 10800 11400 12000 12600 13200 13800 14400 15000 15600 16200 16800 17400 18000 18600 19200 19800 20400 21000 21600 22200 22800 Outlet Vel. 1327 1415 1504 1592 1681 1769 1858 1946 2035 2123 2212 2300 2389 2477 2566 2654 2743 2831 2920 3008 3097 3185 3274 3362 2 1/4” RPM BHP 1069 4.3 1092 4.6 1118 4.9 1147 5.3 1178 5.6 1208 6.0 1240 6.5 1273 6.9 1306 7.4 1340 7.9 1375 8.4 1411 8.9 1448 9.5 1485 10.1 1523 10.7 1562 11.3 1601 12.1 1641 12.8 1681 13.6 1721 14.4 1762 15.3 1804 16.2 1845 17.2 1887 18.2 2 1/2” RPM BHP 1112 4.9 1131 5.1 1155 5.5 1181 5.8 1210 6.2 1240 6.6 1271 7.0 1303 7.5 1335 8.0 1369 8.5 1403 9.0 1437 9.6 1473 10.2 1509 10.8 1546 11.4 1584 12.1 1622 12.8 1661 13.6 1700 14.4 1740 15.2 1780 16.1 1821 17.1 1862 18.0 1903 19.1 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 1212 1228 1249 1275 1302 1332 1362 1392 1424 1457 1490 1523 1557 1593 1629 1665 1703 1740 1778 1817 1856 1896 1936 6.3 6.6 6.9 7.3 7.7 8.2 8.7 9.2 9.8 10.4 11.0 11.6 12.3 13.0 13.7 14.4 15.2 16.1 16.9 17.8 18.8 19.8 20.8 1306 1320 1339 1363 1389 1417 1448 1478 1509 1541 1573 1606 1640 1674 1709 1744 1781 1818 1855 1893 1931 1970 1394 1407 1425 1447 1474 1500 1529 1560 1590 1621 1654 1686 1719 1753 1787 1822 1857 1894 1930 1968 2006 1569 1587 1607 1632 1658 1686 1716 1746 1776 1807 1839 1871 1904 1938 1971 2005 2040 2076 1634 1646 1663 1683 1706 1733 1760 1789 1820 1850 1881 1912 1945 1977 2010 2044 2078 2112 1707 1719 1736 1756 1779 1806 1833 1861 1892 1922 1953 1984 2016 2048 2081 2114 2148 CFM Std. Air 16000 16600 17200 17800 18400 19000 19600 20200 20800 21400 22000 22600 23200 23800 24400 25000 Outlet Vel. 2359 2448 2536 2625 2713 2802 2890 2979 3067 3156 3244 3333 3421 3510 3598 3687 7” RPM 1890 1912 1938 1964 1992 2020 2052 2082 2112 2143 2176 2208 2241 2274 2307 2341 7 1/2” RPM BHP 1938 25.9 1957 26.7 1980 27.5 2006 28.6 2032 29.6 2059 30.7 2088 31.8 2119 33.1 2149 34.3 2180 35.6 2211 36.9 2243 38.5 2275 39.9 2307 41.4 2340 42.9 2374 44.4 8” RPM 1987 2004 2024 2046 2072 2098 2126 2154 2186 2216 2246 2277 2308 2341 2373 2406 BHP 27.9 28.6 29.5 30.4 31.5 32.6 33.7 34.9 36.3 37.6 38.9 40.4 41.8 43.5 45.1 46.7 8 1/2” RPM BHP 2037 30.1 2050 30.7 2068 31.5 2088 32.4 2111 33.4 2138 34.6 2164 35.7 2191 36.9 2220 38.2 2251 39.6 2281 41.0 2311 42.5 2342 44.0 2373 45.5 2406 47.3 2438 49.0 1 BHP 24.0 24.8 25.8 26.7 27.7 28.8 30.0 31.1 32.3 33.6 35.0 36.4 37.8 39.2 40.6 42.1 3 1 5 7.9 8.2 8.5 9.0 9.5 10.0 10.5 11.1 11.7 12.4 13.1 13.8 14.5 15.3 16.1 16.9 17.8 18.7 19.6 20.5 21.6 22.6 3 9.6 9.9 10.3 10.8 11.3 11.9 12.5 13.1 13.8 14.5 15.4 16.1 16.9 17.8 18.6 19.5 20.5 21.4 22.5 23.5 24.6 1478 1490 1508 1529 1554 1581 1609 1639 1669 1700 1731 1764 1796 1830 1863 1897 1932 1968 2004 2041 11.5 11.8 12.2 12.7 13.3 13.9 14.6 15.3 16.0 16.8 17.6 18.6 19.5 20.4 21.3 22.3 23.3 24.4 25.4 26.6 Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 2099 2113 2131 2152 2175 2202 2228 2255 2284 2315 2345 2375 2406 2437 32.9 33.6 34.5 35.4 36.5 37.8 39.0 40.3 41.6 43.1 44.6 46.1 47.7 49.3 2148 2159 2175 2193 2214 2238 2265 2291 2318 2347 2378 2408 2439 35.2 35.8 36.6 37.5 38.6 39.7 41.1 42.4 43.8 45.2 46.8 48.3 49.9 1 1/4” RPM BHP 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 793 816 843 873 903 936 969 1003 1038 1075 1112 1150 1189 1229 1269 1310 1351 1393 1435 1477 1520 1563 1606 8.54 868 890 916 946 976 1008 1040 1074 1108 1144 1180 1218 1256 1295 1334 1375 1415 1456 1498 1540 1582 1624 923 938 960 987 1016 1046 1077 1109 1142 1176 1211 1247 1284 1321 1359 1398 1438 1478 1519 1560 1601 1643 1.8 1.9 2.1 2.3 2.5 2.8 3.0 3.3 3.6 3.9 4.2 4.6 4.9 5.4 5.8 6.3 6.8 7.4 8.0 8.6 9.2 9.9 10.7 13.8 14.2 14.7 15.4 16.1 16.8 17.6 18.4 19.3 20.1 21.2 22.1 23.1 24.1 25.2 26.3 27.4 28.6 2.2 2.3 2.5 2.7 2.9 3.2 3.5 3.8 4.1 4.4 4.8 5.1 5.5 6.0 6.4 6.9 7.4 8.0 8.6 9.2 9.9 10.6 11.4 15.5 15.9 16.4 16.9 17.6 18.4 19.2 20.0 20.9 21.8 22.8 23.8 24.9 26.0 27.1 28.2 29.4 30.6 2.8 2.9 3.1 3.4 3.7 3.9 4.3 4.6 5.0 5.3 5.7 6.1 6.6 7.1 7.5 8.1 8.6 9.3 9.9 10.6 11.3 12.1 17.7 18.1 18.6 19.2 20.0 20.8 21.7 22.5 23.5 24.5 25.6 26.6 27.9 29.0 30.2 31.4 32.7 989 1005 1027 1054 1082 1113 1144 1176 1209 1242 1276 1312 1348 1385 1423 1461 1500 1540 1580 1621 1662 1778 1790 1807 1827 1851 1877 1904 1932 1963 1993 2023 2054 2085 2118 2151 2184 3.4 3.6 3.8 4.1 4.4 4.8 5.1 5.5 5.9 6.3 6.8 7.2 7.7 8.2 8.8 9.3 10.0 10.6 11.3 12.0 12.8 20.0 20.4 21.0 21.7 22.5 23.4 24.3 25.2 26.3 27.4 28.5 29.6 30.8 32.2 33.5 34.8 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 2207 2219 2236 2254 2276 2300 2327 2353 2381 2409 2441 2264 2278 2295 2315 2337 2362 2388 2415 2442 2321 2336 2354 2374 2396 2423 2448 38.2 38.9 39.8 40.8 41.9 43.1 44.5 45.9 47.4 48.9 50.6 41.3 42.1 43.0 44.1 45.3 46.7 48.1 49.6 51.1 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 34 44.5 45.4 46.4 47.6 48.8 50.4 51.8 2366 2377 2394 2412 2433 47.0 47.9 48.8 49.9 51.1 Performance Data Q Fan and Super Q II Size 33 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1 - 10 1.5 - 10 Q Fan Size 33” Min - Max Motor HP Class 2 7.5 - 25 7.5 - 25 Min - Max Motor HP Class 3 20 - 50 20 - 60 35 Super Q Fan Size 33” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1 - 10 7.5 - 20 NA NA Fan Size 36” Wheel Dia. Inlet Area Outlet Area Tip Speed 36.5 inches 9.52 square feet 8.30 square feet 9.56 x RPM ft./minute Performance Data Q Fan and Super Q II Size 36 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 927 mm 0.884 m2 0.771 m2 2.914 m/minute Maximum RPM 1228 1647 2217 Motor 1800 RPM 1200 RPM Minimum Fan RPM 400 266 Table P-8 — Size 36 Q-Fan CFM Std. Air 6000 6800 7600 8400 9200 10000 10800 11600 12400 13200 14000 14800 15600 16400 17200 18000 18800 19600 20400 21200 22000 22800 23600 24400 Outlet Vel. 722 819 915 1012 1108 1204 1301 1397 1493 1590 1686 1783 1879 1975 2072 2168 2265 2361 2457 2554 2650 2746 2843 2939 /4” RPM BHP 409 0.4 445 0.5 483 0.5 523 07 564 08 605 1.0 648 1.2 690 1.4 733 1.6 777 1.9 820 2.2 864 2.6 908 2.9 952 3.4 996 3.8 1041 4.3 1085 4.9 1130 5.5 1174 6.1 1219 6.8 1263 7.6 1308 8.4 1353 9.2 1398 10.2 /8” RPM BHP 446 0.5 4.78 0.6 512 0.7 549 08 586 10 626 1.2 666 1.4 708 1.6 749 1.8 792 2.1 834 2.4 877 2.8 920 3.2 964 3.6 1008 4.1 1051 4.6 1095 5.2 1139 5.8 1183 6.4 1228 7.1 1272 7.9 1316 8.7 1361 9.6 1405 10.5 /2” RPM BHP 481 0.6 510 0.8 542 0.9 575 1.0 611 1.2 647 1.4 686 1.6 725 1.8 766 2.1 807 2.4 849 2.7 891 3.1 933 3.5 976 3.9 1019 4.4 1062 4.9 1106 5.5 1149 6.1 1193 6.8 1237 7.5 1281 8.3 1325 9.1 1369 10.0 1413 10.9 /8” RPM BHP 515 0.8 541 0.9 570 1.1 602 1.2 635 1.4 670 1.6 706 1.8 744 2.0 783 2.3 823 2.6 863 2.9 904 3.3 946 3.7 988 4.2 1030 4.7 1073 5.2 1116 5.8 1159 6.4 1202 7.1 1246 7.8 1290 8.6 1333 9.4 1377 10.3 1421 11.3 Total Static Pressure /4” 1” RPM BHP RPM BHP 550 1.0 571 1.1 633 1.5 598 1.2 651 1.6 628 1.4 677 1.8 659 1.6 706 2.0 692 1.8 736 2.3 727 2.0 769 2.5 763 2.3 802 2.8 800 2.6 836 3.1 839 2.9 872 3.4 878 3.2 909 3.8 918 3.6 947 4.2 959 4.0 986 4.6 1000 4.5 1026 5.1 1042 5.0 1066 5.6 1084 5.5 1107 6.2 1127 6.1 1148 6.8 1169 6.7 1190 7.4 1212 7.4 1232 8.1 1255 8.2 1274 8.9 1298 9.0 1316 9.7 1342 9.8 1359 10.6 1385 10.7 1402 11.5 1429 11.7 1445 12.5 CFM Std. Air 12000 12800 13600 14400 15200 16000 16800 17600 18400 19200 20000 20800 21600 22400 23200 24000 24800 25600 26400 27200 28000 28800 29600 30400 Outlet Vel. 1445 1542 1638 1734 1831 1927 2024 2120 2216 2313 2409 2506 2602 2698 2795 2891 2987 3084 3180 3277 3373 3469 3566 3662 2 1/4” RPM BHP 996 5.8 1022 6.2 1052 6.7 1082 7.2 1113 7.8 1145 8.4 1178 9.0 1211 9.6 1245 10.3 1281 11.0 1317 11.8 1354 12.6 1392 13.4 1430 14.3 1469 15.3 1508 16.3 1548 17.4 1589 18.6 1629 19.8 1670 21.1 1712 22.5 1753 23.9 1795 25.4 1837 27.0 2 1/2” RPM BHP 1029 6.4 1054 6.9 1081 7.3 1111 7.9 1141 8.4 1172 9.1 1204 9.7 1237 10.4 1270 11.1 1304 11.9 1340 12.6 1376 13.5 1412 14.4 1449 15.3 1488 16.2 1526 17.3 1565 18.4 1605 19.6 1645 20.8 1686 22.1 1726 23.5 1767 25.0 1809 26.5 1850 28.1 3” RPM 1100 1118 1142 1167 1195 1225 1256 1287 1319 1351 1385 1419 1454 1489 1526 1563 1600 1638 1677 1716 1756 1796 1836 1877 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 1185 1202 1223 1249 1276 1306 1335 1366 1398 1430 1462 1496 1529 1564 1600 1636 1673 1710 1748 1787 1826 1865 1905 1266 1282 1302 1327 1354 1382 1412 1442 1473 1505 1537 1570 1604 1637 1672 1708 1744 1781 1818 1856 1894 1933 1415 1431 1451 1475 1501 1528 1558 1587 1618 1648 1680 1713 1745 1779 1812 1847 1882 1918 1954 1991 1485 1501 1521 1544 1571 1598 1628 1657 1687 1717 1749 1781 1814 1847 1880 1914 1949 1984 2020 1553 1569 1589 1612 1639 1666 1694 1725 1754 1785 1816 1848 1880 1913 1947 198O 2014 2049 CFM Std. Air 19000 19800 20600 21400 22200 23000 23800 24600 25400 26200 27000 27800 28600 29400 30200 31000 Outlet Vel. 2289 2385 2481 2578 2674 2771 2867 2963 3060 3156 3253 3349 3445 3542 3638 3734 7” RPM 16.95 1714 1737 1764 1790 1818 1848 1878 1908 1939 1970 2002 2035 2067 2101 2134 7 1/2” RPM BHP 1740 31.1 1757 32.0 1777 33.0 1801 34.2 1827 35.7 1854 37.1 1881 38.6 1912 40.2 1941 41.9 1971 43.6 2002 45.3 2034 47.4 2065 49.3 2098 51.3 2130 53.3 2164 55.4 8” RPM 1787 1800 1818 1839 1863 1889 1916 1944 1974 2004 2034 2064 2096 2128 2160 2192 1 BHP 28.7 29.6 30.8 32.1 33.4 34.8 36.3 37.9 39.5 41.1 43.1 44.9 46.7 48.6 50.6 52.6 3 1 BHP 7.9 8.2 8.7 9.3 9.9 10.5 11.2 12.0 12.8 13.6 14.4 15.3 16.2 17.2 18.3 19.3 20.4 21.6 22.9 24.2 25.7 27.1 28.7 30.3 BHP 33.6 34.4 35.4 36.6 37.9 39.4 40.9 42.5 44.3 46.0 47.8 49.7 51.9 54.0 56.1 58.2 5 9.8 10.2 10.8 11.4 12.1 12.8 13.6 14.4 15.3 16.3 17.2 18.2 19.2 20.3 21.4 22.6 23.8 25.1 26.5 27.9 29.4 31.0 32.7 8 1/2” RPM BHP 1845 1860 1878 1900 1925 1950 1977 2005 2036 2065 2095 2126 2157 2189 37.0 37.9 39.0 40.3 41.8 43.4 45.0 46.7 48.5 50.4 52.3 54.3 56.4 58.8 3 12.0 12.4 13.0 13.7 14.4 15.2 16.1 17.0 18.0 19.1 20.2 21.2 22.4 23.6 24.8 26.1 27.4 28.8 30.3 31.8 33.4 35.1 1342 1358 1378 1403 1428 14S6 1486 1516 1546 1578 1610 1642 1675 1709 1743 1778 1814 1850 1887 1924 1961 14.2 14.8 15.4 16.2 17.0 17.9 18.9 19.9 20.9 22.1 23.3 24.5 25.7 27.0 28.4 29.8 31.2 32.7 34.3 35.9 37.6 Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 1891 1902 1918 1937 1959 1985 2011 2037 2065 2096 2126 2156 2186 39.7 40.6 41.6 42.8 44.2 45.8 47.5 49.2 51.0 53.0 55.0 57.0 59.1 1946 1958 1976 1996 2018 2044 2070 2097 2125 2156 2185 2215 43.3 44.3 45.4 46.8 48.2 50.0 51.8 53.6 55.5 57.6 59.7 61.9 1 1/4” RPM BHP 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 708 725 750 779 809 840 873 906 941 977 1014 1052 1090 1130 1170 1211 1251 1293 1335 1377 1419 1461 776 795 819 847 877 908 940 973 1007 1042 1079 1116 1154 1192 1232 1272 1312 1353 1394 1436 1478 841 860 885 912 943 973 1005 1038 1071 1106 1142 1178 1215 1254 1293 1332 1372 1412 1453 1494 2.1 2.2 2.5 2.7 3.0 3.3 3.7 4.0 4.4 4.8 5.3 5.7 6.3 6.8 7.5 8.1 8.9 9.6 10.5 11.4 12.3 13.3 16.7 17.3 18.0 18.8 19.7 20.7 21.8 22.9 24.0 25.2 26.6 27.9 29.3 30.7 32.1 33.6 35.2 36.8 38.5 40.3 2.8 3.0 3.2 3.5 3.8 4.2 4.6 5.0 5.5 5.9 6.4 7.0 7.6 8.2 8.9 9.6 10.4 11.3 12.2 13.1 14.2 19.3 19.9 20.7 21.6 22.6 23.7 24.9 26.1 27.3 28.6 30.1 31.5 33.0 34.5 36.1 37.7 39.4 41.1 42.9 3.5 3.7 4.1 4.4 4.8 5.2 5.7 6.1 6.6 7.2 7.7 8.4 9.0 9.7 10.4 11.2 12.1 13.0 14.0 15.0 22.1 22.8 23.6 24.6 25.7 26.9 28.1 29.4 30.8 32.2 33.8 35.3 36.9 38.5 40.2 42.0 43.8 45.6 902 922 948 975 1006 1036 1068 1100 1134 1168 1203 1239 1276 1314 1352 1391 1431 1471 1511 1606 1618 1635 1655 1679 1705 1732 1760 1791 1821 1851 1882 1914 1946 1979 2012 2045 2079 4.3 4.6 5.0 5.4 5.8 6.3 6.8 7.3 7.9 8.5 9.1 9.8 10.5 11.3 12.1 13.0 13.9 14.9 15.9 24.4 25.0 25.8 26.7 27.7 29.0 30.2 31.5 33.0 34.4 35.9 37.5 39.3 41.0 42.8 44.5 46.4 48.3 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 2000 2014 2032 2053 2076 2102 2128 2155 2184 2215 2042 2054 2070 2088 2109 2133 2160 2186 2213 2094 2107 2124 2143 2165 2191 2216 47.1 48.2 49.4 50.9 52.5 54.4 56.2 58.1 60.2 62.4 50.1 51.1 52.2 53.6 55.2 56.9 58.9 60.9 62.9 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 36 54.0 55.2 56.5 58.0 59.6 61.7 63.6 2145 2160 2178 2198 58.2 59.4 60.8 62.5 Performance Data Q Fan and Super Q II Size 36 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1.5 - 15 1.5 - 15 Q Fan Size 36” Min - Max Motor HP Class 2 10 - 30 10 - 30 Min - Max Motor HP Class 3 25 - 50 25 - 75 37 Super Q Fan Size 36” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1.5 - 15 10 - 30 NA NA Fan Size 40” Wheel Dia. Inlet Area Outlet Area Tip Speed 40.3 inches 11.56 square feet 10.09 square feet 10.54 x RPM ft./minute Performance Data Q Fan and Super Q II Size 40 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 1022 mm 1.074 m2 0.937 m2 3.213 m/minute Maximum RPM 1110 1492 2050 Motor 1800 RPM 1200 RPM Minimum Fan RPM 301 200 Table P-9 — Size 40 Q Fan CFM Std. Air 8000 8800 9600 10400 11200 12000 12800 13600 14400 15200 16000 16800 17600 18400 19200 20000 20800 21600 22400 23200 24000 24800 25600 26400 Outlet Vel. 792 872 951 1030 1110 1189 1268 1347 1427 1506 1585 1665 1744 1823 1902 1982 2061 2140 2220 2299 2378 2457 2537 2616 /4” RPM BHP 395 0.5 422 0.6 451 0.7 481 0.8 512 1.0 543 1.1 574 1.3 606 1.5 638 1.8 670 2.0 702 2.3 735 2.6 767 2.9 800 3.3 833 3.7 866 4.1 899 4.6 932 5.1 965 5.6 998 6.2 1031 6.8 1064 7.4 1098 8.1 1131 8.9 /8” RPM BHP 426 0.7 450 0.8 477 0.9 504 1.1 532 1.2 562 1.4 592 1.6 622 1.8 653 2.0 684 2.3 716 2.6 748 2.9 780 3.2 812 3.6 844 4.0 876 4.4 909 4.9 942 5.4 974 6.0 1007 6.5 1040 7.2 1073 7.8 1106 8.5 1139 9.3 /2” RPM BHP 455 0.9 478 1.0 502 1.1 528 1.3 554 1.4 582 1.6 610 1.8 639 2.0 669 2.3 699 2.5 730 2.8 761 3.2 792 3.5 824 3.9 855 4.3 887 4.8 919 5.3 952 5.8 984 6.3 1016 6.9 1049 7.5 1081 8.2 1114 8.9 1147 9.7 /8” RPM BHP 483 1.1 505 1.2 528 1.3 552 1.5 576 1.7 602 1.9 629 2.1 657 2.3 685 2.6 714 2.8 744 3.1 774 3.5 805 3.8 836 4.2 867 4.7 898 5.1 930 5.6 962 6.1 994 6.7 1026 7.3 1058 7.9 1090 8.6 1123 9.3 1155 10.1 CFM Std. Air 15000 15800 16600 17400 18200 19000 19800 20600 21400 22200 23000 23800 24600 25400 26200 27000 27800 28600 29400 30200 31000 31800 32600 33400 Outlet Vel. 1486 1565 1645 1724 1803 1883 1962 2041 2120 2200 2279 2358 2438 2517 2596 2675 2755 2834 2913 2993 3072 3151 3230 3310 2 1/4” RPM BHP 913 7.2 933 7.7 956 8.2 978 8.7 1001 9.2 1024 9.8 1049 10.4 1073 11.0 1098 11.7 1124 12.4 1150 13.1 1177 13.8 1204 14.6 1232 15.4 1260 16.2 1288 17.1 1317 18.1 1346 19.1 1376 20.1 1406 21.3 1436 22.4 1466 23.6 1496 24.9 1527 26.2 2 1/2” RPM BHP 942 8.0 962 8.5 982 9.0 1005 9.5 1027 10.1 1049 10.6 1073 11.3 1097 12.0 1121 12.6 1146 13.3 1171 14.1 1198 14.9 1224 15.7 1251 16.5 1279 17.4 1306 18.3 1334 19.2 1363 20.2 1392 21.3 1421 22.4 1451 23.6 1480 24.8 1511 26.1 1541 27.5 3” RPM 1004 1019 1037 1056 1076 1099 1121 1143 1167 1191 1215 1240 1265 1290 1316 1343 1370 1397 1425 1453 1481 1510 1539 1568 3 1/2” RPM BHP 1069 11.7 1078 12.0 1091 12.5 1107 13.0 1126 13.6 1146 14.3 1166 15.0 1189 15.7 1211 16.5 1234 17.3 1257 18.3 1281 19.2 1305 20.1 1329 21.0 1354 22.0 1379 23.1 1405 24.1 1431 25.2 1458 26.4 1485 27.6 1513 28.8 1541 30.1 1568 31.3 1597 32.7 CFM Std. Air 23000 23800 24600 25400 26200 27000 27800 28600 29400 30200 31000 31800 32600 33400 34200 35000 Outlet Vel. 2279 2358 2438 2517 2596 2675 2755 2834 2913 2993 3072 3151 3230 3310 3389 3468 7” RPM 1535 1549 1566 1585 1604 1623 1644 1667 1689 1711 1733 1756 1780 1804 1828 1852 7 1/2” RPM BHP 1576 37.7 1589 38.5 1603 39.5 1619 40.7 1638 42.0 1657 43.4 1677 44.8 1697 46.2 1718 47.8 1742 49.5 1764 51.1 1786 52.8 1809 54.6 1832 56.4 1856 58.6 1880 60.5 8” RPM 1619 1629 1641 1655 1672 1690 1709 1729 1749 1770 1793 1815 1838 1860 1883 1907 1 BHP 34.8 35.7 36.8 38.1 39.3 40.6 42.0 43.5 45.0 46.6 48.2 49.9 51.8 53.6 55.5 57.3 3 1 BHP 9.7 10.1 10.7 11.2 11.8 12.4 13.1 13.8 14.6 15.4 16.2 17.0 17.8 18.8 19.7 20.6 21.7 22.7 23.8 24.9 26.1 27.4 28.7 30.0 BHP 40.7 41.5 42.5 43.5 44.7 46.2 47.6 49.1 50.7 52.3 54.1 55.8 57.6 59.5 61.5 63.7 5 Total Static Pressure /4” 1” RPM BHP RPM BHP 511 1.3 571 1.8 530 1.4 582 1.9 552 1.6 599 2.1 575 1.7 619 2.2 598 1.9 641 2.5 623 2.2 663 2.7 648 2.4 687 3.0 675 2.6 711 3.2 702 2.9 736 3.5 730 3.1 762 3.8 759 3.5 789 4.1 788 3.8 817 4.5 818 4.2 845 4.9 848 4.6 873 5.3 878 5.0 902 5.7 909 5.5 932 6.2 940 6.0 962 6.7 972 6.5 993 7.3 1003 7.1 1023 7.9 1035 7.7 1054 8.5 1067 8.3 1085 9.2 1099 9.0 1117 9.8 1131 9.8 1148 10.6 1163 10.5 1180 11.4 3 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 647 662 681 701 724 747 771 795 820 846 872 900 927 956 985 1014 1044 1074 1104 1135 1165 1196 707 721 739 759 781 804 827 851 876 901 926 953 980 1008 1036 1065 1094 1123 1153 1183 1214 763 777 795 814 836 858 881 905 929 954 979 1005 1031 1059 1086 1114 1143 1172 1201 1231 2.6 2.8 3.0 3.2 3.5 3.8 4.2 4.5 4.9 5.2 5.6 6.1 6.5 7.0 7.5 8.1 8.7 9.4 10.0 10.8 11.5 12.4 3.4 3.6 3.9 4.1 4.5 4.8 5.2 5.6 6.0 6.4 6.9 7.4 7.9 8.4 9.0 9.6 10.3 11.0 11.7 12.5 13.3 4.3 4.5 4.8 5.1 5.5 5.9 6.3 6.8 7.2 7.7 8.2 8.8 9.3 9.9 10.6 11.2 11.9 12.7 13.5 14.3 816 830 848 867 888 910 933 957 980 1005 1030 1055 1081 1108 1136 1163 1191 1220 1249 5.2 5.5 5.8 6.2 6.6 7.0 7.5 8.0 8.5 9.1 9.7 10.3 10.9 11.5 12.2 13.0 13.7 14.5 15.4 Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 1149 1161 1175 1192 1212 1232 1253 1276 1298 1321 1344 1368 1392 1416 1441 1466 1492 1518 1544 1571 1599 1626 1280 1290 1304 1319 1338 1357 1377 1397 1420 1442 1465 1488 1512 1535 1560 1584 1609 1634 1659 1685 1342 1351 1364 1379 1396 1416 1436 1456 1479 1501 1523 1546 1569 1593 1616 1641 1665 1690 1715 1401 1410 1423 1438 1454 1474 1493 1513 1534 1557 1579 1602 1625 1649 1672 1696 1720 1745 14.6 15.0 15.6 16.2 17.0 17.7 18.5 19.4 20.3 21.3 22.3 23.4 24.4 25.5 26.6 27.8 29.0 30.2 31.5 32.8 34.2 35.6 1216 1227 1241 1257 1276 1295 1316 1338 1360 1383 1405 1429 1453 1477 1501 1526 1551 1576 1602 1629 1656 17.3 17.7 18.3 19.0 19.8 20.7 21.5 22.5 23.5 24.5 25.6 26.8 28.0 29.2 30.4 31.6 32.9 34.3 35.6 37.1 38.6 8 1/2” RPM BHP Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 1670 1680 1692 1707 1723 1740 1760 1780 1800 1821 1844 1866 1889 1911 1934 1720 1730 1743 1757 1773 1791 1811 1830 1851 1871 1895 1916 1939 1961 44.7 45.6 46.6 47.7 49.0 50.4 52.1 53.6 55.3 57.0 58.9 60.7 62.6 64.6 66.6 1 1/4” RPM BHP 48.8 49.8 50.8 52.1 53.4 54.9 56.7 58.3 60.0 61.8 63.9 65.8 67.8 69.9 1768 1779 1792 1806 1823 1840 1860 1880 1900 1921 1944 1966 1988 53.1 54.1 55.3 56.6 58.0 59.6 61.4 63.2 65.0 66.9 69.0 71.1 73.2 20.1 20.7 21.3 22.0 22.9 23.8 24.7 25.7 26.9 28.0 29.1 30.3 31.7 33.0 34.3 35.7 37.0 38.5 40.0 41.5 23.2 23.7 24.4 25.2 26.0 27.1 28.1 29.2 30.4 31.6 32.8 34.1 35.4 37.0 38.4 39.9 41.4 42.9 44.5 26.4 27.0 27.7 28.5 29.4 30.6 31.7 32.8 34.0 35.4 36.7 38.1 39.5 41.2 42.7 44.3 45.9 47.5 1458 1467 1480 1494 1511 1530 1549 1569 1590 1613 1635 1657 1680 1703 1727 1750 1774 29.7 30.4 31.1 32.0 33.0 34.2 35.4 36.6 37.9 39.4 40.8 42.2 43.8 45.4 47.2 48.9 50.6 10” RPM BHP 10 1/2” RPM BHP 11” 11 1/2” RPM BHP RPM BHP 1807 1816 1827 1840 1855 1871 1890 1909 1928 1949 1969 1993 1854 1862 1874 1887 1902 1919 1938 1957 1976 1899 1908 1921 1934 1949 1966 1985 56.6 57.5 58.6 59.8 61.2 62.7 64.6 66.4 68.2 70.1 72.1 74.4 61.1 62.1 63.3 64.6 66.1 67.7 69.7 71.5 73.4 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 38 65.7 66.8 68.1 69.5 71.0 72.8 74.9 1944 1954 1966 1980 70.5 71.7 73.0 74.5 Performance Data Q Fan and Super Q II Size 40 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 1.5 - 15 1.5 - 15 Q Fan Size 40” Min - Max Motor HP Class 2 10 - 40 10 - 40 Min - Max Motor HP Class 3 30 - 50 30 - 75 39 Super Q Fan Size 40” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 1.5 - 15 10 - 40 NA NA Fan Size 44” Wheel Dia. Inlet Area Outlet Area Tip Speed 44.5 inches 14.14 square feet 12.33 square feet 11.65 x RPM ft./minute Performance Data Q Fan and Super Q II Size 44 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II III 1130 mm 1.314 m2 1.145 m2 3.551 m/minute Maximum RPM 1070 1352 1922 Motor 1800 RPM 1200 RPM Minimum Fan RPM 289 192 Table P-10 — Size 44 Q-Fan CFM Std. Air 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000 19000 20000 21000 22000 23000 24000 25000 26000 27000 28000 29000 30000 31000 32000 Outlet Vel. 729 811 892 973 1054 1135 1216 1297 1378 1459 1540 1622 1703 1784 1865 1946 2027 2108 2189 2270 2351 2433 2514 2595 /4” RPM BHP 335 0.5 360 0.7 386 0.8 413 0.9 440 1.1 468 1.2 496 1.4 525 1.7 554 1.9 583 2.2 612 2.5 641 2.9 671 3.2 701 3.6 730 4.1 760 4.6 790 5.1 820 5.7 850 6.3 880 6.9 910 7.6 941 8.4 971 9.2 1001 10.0 /8” RPM BHP 364 0.7 385 0.9 409 1.0 434 1.2 460 1.3 487 1.5 514 1.7 541 2.0 569 2.2 597 2.5 626 2.9 654 3.2 683 3.6 712 4.0 742 4.5 771 5.0 800 5.5 830 6.1 860 6.7 889 7.4 919 8.1 949 8.9 979 9.7 1009 10.6 /2” RPM BHP 392 1.0 412 1.1 433 1.2 456 1.4 480 1.6 505 1.8 531 2.0 557 2.3 584 2.6 612 2.9 639 3.2 667 3.6 696 4.0 724 4.4 753 4.9 782 5.4 811 6.0 840 6.6 869 7.2 899 7.9 928 8.6 958 9.4 987 10.2 1017 11.1 /8” RPM BHP 420 1.2 437 1.3 457 1.5 478 1.7 500 1.9 523 2.1 548 2.4 574 2.6 600 2.9 626 3.2 653 3.6 681 4.0 708 44 736 4.8 764 5.3 793 5.9 821 6.4 850 7.0 879 7.7 908 8.4 937 9.1 966 9.9 996 10.7 1025 11.6 Total Static Pressure /4” 1” RPM BHP RPM BHP 451 1.5 463 1.6 517 2.2 480 1.8 526 2.4 499 2.0 542 2.6 520 2.2 559 2.8 542 2.4 580 3.0 565 2.7 600 3.3 590 3.0 622 3.7 615 3.3 645 4.0 641 3.6 669 4.4 667 4.0 694 4.8 694 4.4 719 5.2 721 4.8 745 5.7 748 5.3 772 6.2 776 5.8 798 6.7 804 6.3 825 7.3 832 6.9 853 7.9 860 7.5 880 8.5 889 8.2 908 9.2 917 8.9 936 9.9 946 9.6 964 10.7 975 10.4 992 11.5 1004 11.3 1021 12.4 1033 12.2 1050 13.4 CFM Std. Air 16000 17000 18000 19000 20000 21000 22000 23000 24000 25000 26000 27000 28000 29000 30000 31000 32000 33000 34000 35000 36000 37000 38000 39000 Outlet Vel. 1297 1378 1459 1540 1622 1703 1784 1865 1946 2027 2108 2189 2270 2351 2433 2514 2595 2676 2757 2838 2919 3000 3081 3163 2 1/4” RPM BHP 784 7.8 796 8.2 813 8.7 830 9.2 849 9.7 869 10.3 890 10.9 911 11.6 933 12.3 956 13.1 979 13.9 1004 14.8 1029 15.7 1054 16.6 1079 17.6 1105 18.6 1131 19.7 1157 20.8 1184 22.0 1211 23.2 1238 24.5 1265 25.8 1293 27.2 1320 28.7 2 1/2” RPM BHP 818 8.9 828 9.2 841 9.6 857 10.2 874 10.7 893 11.3 914 12.0 934 12.6 955 13.4 977 14.2 999 15.0 1023 15.9 1047 16.8 1072 17.9 1096 18.9 1122 19.9 1147 21.0 1173 22.2 1199 23.4 1226 24.6 1252 25.9 1279 27.3 1306 28.8 1334 30.3 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 5” RPM BHP 5 1/2” RPM BHP 6” 6 1/2” RPM BHP RPM BHP 901 911 925 942 960 978 999 1019 1040 1061 1084 1107 1130 1154 1180 1205 1230 1255 1281 1307 1334 1360 969 978 990 1005 1023 1041 1060 1080 1101 1122 1143 1165 1188 1211 1235 1260 1285 1310 1335 1361 1387 1033 1043 1053 1067 1083 1101 1119 1139 1159 1180 1201 1222 1244 1267 1290 1314 1338 1363 1388 1413 1161 1170 1182 1197 1214 1231 1250 1270 1290 1310 1331 1352 1373 1396 1419 1442 1466 1216 1225 1237 1251 1268 1285 1303 1322 1342 1362 1383 1404 1425 1447 1469 1492 1270 1279 1290 1304 1320 1337 1355 1373 1394 1414 1434 1455 1476 1497 1519 CFM Std. Air 28000 29000 30000 31000 32000 33000 34000 35000 36000 37000 38000 39000 40000 41000 42000 43000 Outlet Vel. 2270 2351 2433 2514 2595 2676 2757 2838 2919 3000 3081 3163 3244 3325 3406 3487 7” RPM 1381 1392 1405 1420 1437 1455 1473 1492 1512 1532 1553 1574 1595 1616 1638 1661 7 1/2” RPM BHP 1420 46.7 1430 47.6 1440 48.5 1453 49.7 1468 51.1 1486 52.9 1503 54.6 1521 56.3 1540 58.1 1560 60.0 1580 61.9 1601 63.9 1621 66.0 1642 68.2 1664 70.5 1685 73.1 8” RPM 1458 1468 1476 1488 1501 1516 1533 1550 1568 1587 1607 1627 1647 1668 1689 1 BHP 42.9 43.7 44.9 46.2 47.9 49.5 51.1 52.7 54.5 56.3 58.2 60.2 62.3 64.7 66.9 69.3 3 1 11.9 12.3 12.8 13.5 14.1 14.9 15.6 16.4 17.3 18.3 19.3 20.3 21.4 22.5 23.8 25.0 26.3 27.6 29.0 30.4 31.9 33.4 BHP 50.6 51.6 52.3 53.4 54.7 56.2 58.2 59.9 61.7 63.6 65.6 67.7 69.8 72.0 74.3 5 14.8 15.2 15.7 16.4 17.2 18.0 18.9 19.8 20.7 21.7 22.9 24.0 25.2 26.4 27.7 29.2 30.6 32.0 33.5 35.1 36.7 8 1/2” RPM BHP 1505 1514 1522 1534 1547 1562 1580 1597 1615 1633 1652 1673 55.6 56.6 57.4 58.6 59.9 61.5 63.6 65.5 67.4 69.4 71.4 73.7 3 18.0 18.5 18.9 19.6 20.5 21.4 22.3 23.3 24.4 25.5 26.6 28.0 29.2 30.6 32.0 33.5 35.0 36.7 38.3 40.0 1094 1103 1113 1126 1141 1158 1176 1195 1215 1235 1256 1277 1298 1321 1343 1367 1390 1415 1440 21.3 21.9 22.4 23.1 23.9 25.0 26.0 27.1 28.3 29.4 30.7 32.0 33.5 35.0 36.5 38.1 39.7 41.4 43.3 Total Static Pressure 9” 9 1/2” RPM BHP RPM BHP 1550 1559 1568 1579 1593 1608 1625 1642 1660 60.7 61.8 62.6 63.9 65.4 67.1 69.3 71.3 73.3 1594 1603 1612 1624 1637 1652 66.0 67.2 68.1 69.4 71.0 72.8 1 1/4” RPM BHP 1 1/2” RPM BHP 1 3/4” 2” RPM BHP RPM BHP 585 598 616 635 655 676 698 721 745 770 795 821 847 873 900 927 955 982 1010 1038 1066 639 652 669 687 707 727 748 771 794 818 843 869 894 920 947 973 1000 1027 1055 1082 691 702 719 736 756 776 797 819 842 865 890 915 940 966 992 1018 1045 1072 1099 3.3 3.5 3.7 4.0 4.4 4.7 5.2 5.6 6.1 6.6 7.1 7.7 8.2 8.9 9.5 10.3 11.0 11.8 12.7 13.6 14.6 25.5 26.0 26.8 27.7 28.9 30.0 31.1 32.4 33.7 35.0 36.4 37.9 39.6 41.2 42.9 44.7 46.5 10” RPM BHP 1637 1646 1655 4.2 4.5 4.8 5.2 5.5 6.0 6.4 6.9 7.4 8.0 8.6 9.3 9.9 10.6 11.4 12.2 13.0 13.9 14.8 15.8 29.4 29.9 30.7 31.7 32.9 34.1 35.4 36.7 38.1 39.5 41.1 42.6 44.3 46.2 48.0 49.9 10 1/2” RPM BHP 71.5 72.7 73.7 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 40 5.4 5.6 6.0 6.4 6.8 7.3 7.8 8.4 9.0 9.6 10.3 11.0 11.7 12.5 13.3 14.2 15.1 16.0 17.1 33.4 34.0 34.8 35.8 37.2 38.5 39.9 41.3 42.8 44.3 45.9 47.6 49.4 51.4 53.4 729 738 750 767 784 804 824 844 866 888 911 935 960 985 1010 1036 1062 1088 1115 1322 1331 1342 1355 1370 1388 1405 1424 1443 1464 1484 1504 1525 1547 6.3 6.5 6.8 7.3 7.7 8.2 8.7 9.3 9.9 10.6 11.3 12.0 12.8 13.7 14.5 15.4 16.3 17.3 18.4 37.6 38.4 39.2 40.3 41.5 43.1 44.5 46.0 47.6 49.3 51.0 52.8 54.7 56.7 11” 11 1/2” RPM BHP RPM BHP Performance Data Q Fan and Super Q II Size 44 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 3 - 20 3 - 20 Q Fan Size 44” Min - Max Motor HP Class 2 15 - 40 15 - 40 Min - Max Motor HP Class 3 40 - 50 40 - 75 41 Super Q Fan Size 44” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 3 - 20 15 - 40 NA NA Fan Size 49” Wheel Dia. Inlet Area Outlet Area Tip Speed 49.0 inches 14.96 square feet 14.96 square feet 12.83 x RPM ft./minute Performance Data Q Fan Size 49 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II 1245 mm 1.390 m2 1.390 m2 3.911 m/minute Maximum RPM 949 1274 Motor 1800 RPM 1200 RPM Minimum Fan RPM 301 201 Table P-11 — Size 49 Q-Fan CFM OutStd. let Air Vel. 13000 868 •14000 935 15000 1002 •160001069 17000 1136 18000 1203 19000 1270 20000 1336 21000 1403 22000 1470 23000 1537 •240001604 25000 1671 26000 1737 27000 1804 28000 1871 29000 1938 30000 2005 31000 2072 32000 2139 33000 2205 34000 2272 35000 2339 36000 2406 /4” RPM BHP 353 1.0 373 1.1 394 1.3 415 1.4 437 1.6 458 1.9 480 2.1 503 2.4 525 2.7 548 3.0 570 3.4 593 3.7 616 4.2 639 4.6 662 5.1 685 5.6 708 6.1 731 6.7 754 7.3 777 8.0 801 8.7 824 9.4 847 10.2 871 11.0 /8” RPM BHP 376 1.2 395 1.4 414 1.6 434 1.8 454 2.0 475 2.2 496 2.5 517 2.8 539 3.1 560 3.4 582 3.8 605 4.2 627 4.6 649 5.1 672 5.6 695 6.1 717 6.6 740 7.2 763 7.9 786 8.6 809 9.3 832 10.0 855 10.8 878 11.7 /2” RPM BHP 400 1.6 417 1.7 435 1.9 453 2.1 472 2.4 492 2.6 511 2.9 532 3.2 552 3.5 574 3.9 595 4.2 616 4.6 638 5.1 660 5.6 682 6.1 704 6.6 727 7.2 749 7.8 772 8.4 794 9.1 817 9.9 840 10.6 863 11.4 886 12.3 /8” RPM BHP 425 1.9 439 2.1 455 2.3 472 2.5 490 2.7 509 3.0 528 3.3 547 3.6 567 3.9 587 4.3 608 4.7 629 5.1 650 5.6 671 6.1 693 6.6 715 7.1 737 7.7 759 8.3 781 9.0 803 9.7 826 10.5 848 11.2 871 12.1 893 13.0 Total Static Pressure /4” 1” RPM BHP RPM BHP 451 2.3 463 2.4 476 2.6 521 3.5 492 2.9 532 3.7 508 3.1 545 4.0 525 3.4 560 4.3 544 3.7 576 4.6 563 4.1 593 4.9 582 4.4 611 5.3 601 4.8 629 5.8 621 5.2 648 6.2 641 5.6 667 6.7 662 6.1 686 7.2 682 6.6 706 7.7 704 7.1 726 8.2 725 7.7 746 8.8 746 8.3 767 9.5 768 8.9 788 10.1 790 9.6 809 10.8 812 10.3 830 11.6 834 11.1 851 12.4 856 11.9 873 13.2 879 12.7 895 14.1 901 13.6 917 15.0 CFM Std. Air 23000 24000 25000 26000 27000 28000 29000 30000 31000 32000 33000 34000 35000 36000 37000 38000 39000 40000 41000 42000 43000 44000 45000 46000 2 1/4” RPM BHP 787 12.0 798 12.6 811 13.1 825 13.8 840 14.4 856 15.1 873 15.8 890 16.6 907 17.5 925 18.4 944 19.4 962 20.4 981 21.4 1000 22.5 1020 23.6 1039 24.8 1058 25.9 1078 27.1 1099 28.4 1119 29.8 1140 31.2 1160 32.6 1181 34.2 1202 35.7 2 1/2” RPM BHP 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 827 838 851 864 879 894 910 927 944 962 980 999 1017 1036 1055 1075 1094 1114 1133 1154 1174 1195 1215 903 913 925 939 953 968 983 999 1016 1033 1051 1069 1088 1106 1125 1144 1163 1183 1202 1222 1241 974 985 996 1009 1023 1038 1053 1069 1085 1102 1120 1137 1155 1174 1193 1211 1230 1250 1269 Outlet Vel. 1537 1604 1671 1737 1804 1871 1938 2005 2072 2139 2205 2272 2339 2406 2473 2540 2606 2673 2740 2807 2874 2941 3008 3074 1 3 13.9 14.5 15.2 15.8 16.5 17.3 18. 1 18.9 19.8 20.8 21.9 23.0 24.1 25.2 26.4 27.6 28.9 30.2 31.6 33.0 34.5 36.0 37.6 1 18.1 18.8 19.5 20.3 21.2 22.0 22.9 23.9 24.9 26.0 27.2 28.4 29.8 31.1 32.4 33.8 35.3 36.8 38.3 39.8 41.5 5 22.8 23.6 24.4 25.3 26.3 27.3 28.3 29.4 30.5 31.7 33.0 34.4 35.8 37.5 39.0 40.6 42.2 43.8 45.5 3 1042 1053 1064 1077 1091 1105 1120 1136 1152 1169 1186 1203 1221 1240 1258 27.9 28.8 29.7 30.8 31.9 33.0 34.2 35.4 36.6 38.0 39.4 40.9 42.5 44.3 46.1 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 42 1107 1118 1129 1143 1156 1171 1186 1201 1217 1234 1251 1268 33.5 34.5 35.6 36.8 38.0 39.2 40.5 41.9 43.3 44.8 46.4 48.0 1 1/4” RPM BHP 585 596 610 624 640 657 674 692 711 730 749 768 788 808 828 848 869 890 911 933 4.9 5.2 5.6 5.9 6.3 6.7 7.2 7.7 8.3 8.8 9.4 10.0 10.7 11.4 12.1 12.9 13.7 14.5 15.4 16.4 5” RPM BHP 1170 1181 1192 1206 1220 1234 1249 1264 39.5 40.6 41.9 43.2 44.5 45.9 47.4 48.9 1 1/2” RPM BHP 645 657 671 685 701 718 735 753 772 790 809 828 848 867 887 908 928 949 6.6 7.0 7.4 7.8 8.3 8.8 9.3 9.9 10.6 11.3 12.0 12.7 13.5 14.2 15.1 15.9 16.9 17.8 5 1/2” RPM BHP 1221 1230 1242 1254 44.8 46.0 47.3 48.6 1 3/4” 2” RPM BHP RPM BHP 691 702 715 729 744 760 777 794 812 830 849 868 887 906 926 946 966 8.1 8.5 9.0 9.5 10.0 10.5 11.1 11.8 12.5 13.2 14.0 14.8 15.6 16.5 17.4 18.4 19.3 745 757 771 785 801 817 834 851 869 888 906 925 944 964 983 10.2 10.7 11.2 11.8 12.4 13.0 13.7 14.5 15.3 16.2 17.1 18.0 18.9 19.9 20.9 6” 6 1/2” RPM BHP RPM BHP Performance Data Q Fan Size 49 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Super Q II fans are NOT available in size 49. Horizontal fans only, for vertical units contact marketing in Lexington. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 2 - 20 — Q Fan Size 49” Min - Max Motor HP Class 2 20 - 50 — Min - Max Motor HP Class 3 — — 43 Super Q Fan Size 49” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 NA NA NA NA Fan Size 54” Wheel Dia. Inlet Area Outlet Area Tip Speed 54.3 inches 18.37 square feet 18.37 square feet 14.20 x RPM ft./minute Performance Data Q Fan Size 54 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II 1378 mm 1.707 m2 1.707 m2 4.328 m/minute Maximum RPM 857 1151 Motor 1800 RPM 1200 RPM Minimum Fan RPM 292 195 Table P-12 — Size 54 Q-Fan CFM Std. Air 16200 17600 19000 20400 21800 23200 24600 26000 27400 28800 30200 31600 33000 34400 35800 37200 38600 40000 41400 42800 44200 45600 47000 48400 Outlet Vel. 881 958 1034 1110 1186 1262 1339 1415 1491 1567 1643 1720 1796 1872 1948 2025 2101 2177 2253 2329 2406 2482 2558 2634 /4” RPM BHP 323 1.2 344 1.4 365 1.7 387 1.9 410 2.2 432 2.6 455 3.0 479 3.4 502 3.8 525 4.3 549 4.9 572 5.5 596 6.2 620 6.9 644 7.7 668 8.5 691 9.4 715 10.3 739 11.4 763 12.4 788 13.6 812 14.8 836 16.1 860 17.5 /8” RPM BHP 344 1.6 363 1.8 383 2.1 403 2.3 425 2.7 446 3.0 468 3.4 491 3.9 513 4.3 536 4.9 559 5.5 582 6.1 605 6.8 629 7.5 652 8.3 676 9.1 699 10.1 723 11.0 747 12.1 770 13.2 794 14.4 818 15.6 842 17.0 866 18.4 /2” RPM BHP 365 1.9 382 2.2 401 2.5 420 2.8 440 3.1 460 3.5 481 3.9 503 4.4 525 4.9 547 5.4 569 6.0 592 67 615 7.4 638 8.1 661 8.9 684 9.8 707 10.8 731 11.7 754 12.8 778 13.9 801 15.1 825 16.4 849 17.8 872 19.2 /8” RPM BHP 387 2.4 402 2.6 419 2.9 437 3.2 456 3.6 475 4.0 495 4.5 516 4.9 537 5.4 558 6.0 580 6.6 602 7.3 624 8.0 647 8.8 669 9.6 692 10.5 715 11.5 738 12.5 761 13.6 785 14.7 808 15.9 831 17.2 855 18.6 879 20.1 Total Static Pressure /4” 1” RPM BHP RPM BHP 410 2.8 422 3.1 437 3.4 475 4.4 454 3.7 488 4.8 471 4.1 503 5.2 490 4.5 519 5.6 509 5.0 537 6.1 529 5.5 555 6.6 549 6.0 574 7.2 570 6.6 594 7.9 591 7.2 613 8.6 612 7.9 633 9.3 634 8.7 654 10.0 656 9.5 675 10.9 678 10.3 696 11.8 701 11.2 718 12.7 723 12.2 740 13.7 746 13.2 762 14.8 769 14.3 784 15.9 792 15.5 807 17.1 815 16.8 829 18.4 838 18.1 852 19.8 862 19.5 875 21.2 885 20.9 898 22.7 CFM Std. Air 29000 30400 31800 33200 34600 36000 37400 38800 40200 41600 43000 44400 45800 47200 48600 50000 51400 52800 54200 55600 57000 58400 59800 Outlet Vel. 1578 1654 1731 1807 1883 1959 2035 2112 2188 2264 2340 2416 2493 2569 2645 2721 2798 2874 2950 3026 3102 3179 3255 2 1/4” RPM BHP 717 15.2 730 16.0 745 16.8 760 17.7 777 18.7 794 19.8 811 20.9 830 22.2 849 23.6 868 25.0 888 26.4 907 27.9 927 29.4 948 31.1 968 32.7 988 34.5 1010 36.4 1031 38.4 1052 40.4 1074 42.6 1096 44.8 1118 47.1 1140 49.5 2 1/2” RPM BHP 744 16.9 755 17.7 767 18.5 782 19.5 797 20.5 813 21.6 830 22.7 847 23.9 865 25.2 884 26.8 903 28.3 923 29.8 942 31.5 962 33.1 982 34.9 1002 36.7 1023 38.6 1043 40.6 1064 42.7 1086 44.8 1107 47.1 1129 49.5 1151 51.9 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 815 826 838 852 867 883 900 917 935 953 972 991 1010 1030 1050 1070 1090 1110 1130 1151 882 893 906 920 935 950 967 984 1001 1019 1038 1057 1076 1095 1115 1135 1 3 1 22.2 23.1 24.2 25.3 26.5 27.7 29.0 30.5 32.0 33.6 35.5 37.3 39.2 41.1 43.1 45.2 47.4 49.5 51.9 54.3 5 28.2 29.3 30.5 31.8 33.2 34.6 36.1 37.7 39.5 41.3 43.3 45.5 47.7 49.9 52.1 54.5 3 946 957 970 985 999 1015 1032 1048 1066 1084 1102 1121 1140 34.8 36.1 37.5 39.0 40.6 42.2 43.9 45.8 47.7 49.8 52.0 54.5 56.9 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 44 997 1007 1019 1033 1047 1062 1078 1094 1111 1129 1146 40.6 42.0 43.5 45.2 46.9 48.6 50.5 52.4 54.5 56.7 59.0 1 1/4” RPM BHP 536 550 565 581 599 617 636 655 675 695 715 736 757 778 800 822 844 866 888 911 6.3 6.8 7.3 7.8 8.4 9.1 9.9 10.7 11.5 12.4 13.3 14.2 15.3 16.4 17.6 18.8 20.2 21.5 23.0 24.6 5” RPM BHP 1056 1067 1080 1094 1108 1123 1139 48.3 49.9 51.6 53.5 55.4 57.4 59.5 1 1/2” RPM BHP 582 594 608 624 641 658 676 696 715 734 754 775 795 816 837 858 880 902 924 8.1 8.6 9.2 9.8 10.5 11.2 12.0 12.9 13.9 14.9 15.9 17.0 18.1 19.3 20.6 21.9 23.4 24.9 26.5 5 1/2” RPM BHP 1103 1113 1125 55.0 56.7 58.5 1 3/4” 2” RPM BHP RPM BHP 625 636 650 665 681 698 716 734 753 773 792 812 833 853 873 894 916 937 10.0 10.6 11.2 11.9 12.7 13.5 14.4 15.3 16.4 17.5 18.7 19.9 21.1 22.4 23.8 25.3 26.8 28.4 666 677 690 705 720 737 754 772 791 810 829 849 869 889 909 930 951 12.1 12.7 13.5 14.2 15.0 15.9 16.9 17.9 19.2 20.4 21.6 22.9 24.3 25.7 27.2 28.8 30.4 6” 6 1/2” RPM BHP RPM BHP Performance Data Q Fan Size 54 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Super Q fans are NOT available in size 54. Horizontal fans only, for vertical units contact marketing in Lexington. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 2 -25 — Q Fan Size 54” Min - Max Motor HP Class 2 20 - 60 — Min - Max Motor HP Class 3 — — 45 Super Q Fan Size 54” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 NA NA NA NA Fan Size 60” Wheel Dia. Inlet Area Outlet Area Tip Speed 60.0 inches 22.38 square feet 22.38 square feet 15.71 x RPM ft./minute Performance Data Q Fan Size 60 Pressure Class Limits Minimum Fan RPM (Without VFRB Option) Class I II 1524 mm 2.079 m2 2.079 m2 4.788 m/minute Maximum RPM 775 1040 Motor 1800 RPM 1200 RPM Minimum Fan RPM 314 209 Table P-13 — Size 60 Q-Fan CFM Std. Air 19800 21400 23000 24600 26200 27800 29400 31000 32600 34200 35800 37400 39000 40600 42200 43800 45400 47000 48600 50200 51800 53400 55000 56600 Outlet Vel. 884 956 1027 1099 1170 1242 1313 1385 1456 1528 1599 1671 1742 1814 1885 1957 2028 2100 2171 2243 2314 2386 2457 2529 /4” RPM BHP 291 1.5 309 1.7 327 2.0 346 2.3 365 2.6 384 3.0 403 3.4 423 3.9 442 4.4 462 4.9 482 5.5 502 6.2 522 6.9 542 7.7 562 8.5 582 9.4 602 10.3 622 11.3 643 12.4 663 13.6 683 14.8 704 16.1 724 17.5 744 18.9 /8” RPM BHP 311 1.9 327 2.2 344 2.5 361 2.8 379 3.2 397 3.6 415 4.0 434 4.5 453 5.0 472 5.6 491 6.2 511 6.9 530 7.6 550 8.4 570 9.2 590 10.1 610 11.1 630 12.2 650 13.3 670 14.4 690 15.7 710 17.0 730 18.4 750 19.9 /2” RPM BHP 330 2.4 344 2.6 360 3.0 376 3.3 393 3.7 410 4.1 428 4.6 446 5.1 464 5.6 482 6.2 501 6.9 520 7.6 539 8.3 559 9.1 578 10.0 597 10.9 617 11.9 637 13.0 656 14.1 676 15.3 696 16.6 716 17.9 736 19.4 756 20.9 /8” RPM BHP 350 2.9 362 3.2 376 3.5 391 3.9 407 4.3 424 4.7 441 5.2 458 5.7 475 6.3 493 6.9 511 7.6 530 8.3 548 9.1 567 9.9 586 10.8 605 11.8 625 12.8 644 13.9 663 15.0 683 16.2 703 17.5 722 18.9 742 20.4 762 21.9 Total Static Pressure /4” 1” RPM BHP RPM BHP 370 3.5 381 3.7 393 4.1 428 5.3 407 4.4 439 5.7 422 4.9 451 6.2 437 5.3 464 6.7 453 5.9 479 7.2 470 6.4 494 7.8 487 7.0 510 8.5 504 7.7 526 9.2 521 8.3 543 9.9 539 9.1 560 10.7 558 9.9 576 11.5 576 10.7 594 12.4 595 11.6 612 13.4 613 12.6 630 14.4 632 13.7 648 15.5 651 14.8 666 16.6 671 15.9 685 17.8 690 17.2 704 19.1 709 18.5 723 20.5 729 19.9 742 21.9 748 21.4 761 23.4 768 22.9 780 25.0 CFM Std. Air 35000 36600 38200 39800 41400 43000 44600 46200 47800 49400 51000 52600 54200 55800 57400 59000 60600 62200 63800 65400 67000 68600 70200 71800 Outlet Vel. 1563 1635 1706 1778 1849 1921 1992 2064 2135 2207 2278 2350 2421 2493 2564 2636 2707 2779 2850 2922 2993 3065 3136 3208 2 1/4” RPM BHP 645 18.3 656 19.2 668 20.1 681 21.2 694 22.2 708 23.4 723 24.6 738 26.0 754 27.4 770 29.1 786 30.6 803 32.3 819 34.0 836 35.8 853 37.6 870 39.5 888 41.5 905 43.6 923 45.8 941 48.1 959 50.5 978 53.0 996 55.6 1015 58.3 2 1/2” RPM BHP 3” RPM BHP 3 1/2” RPM BHP Total Static Pressure 4” 4 1/2” RPM BHP RPM BHP 1 3 679 689 701 713 726 740 754 769 785 801 817 833 850 866 883 900 917 935 952 970 988 1006 1025 21.3 22.2 23.3 24.4 25.6 26.8 28.1 29.6 31.1 32.9 34.6 36.4 38.2 40.1 42.1 44.2 46.3 48.5 50.8 53.3 55.8 58.4 61.2 1 742 752 763 775 788 801 816 830 845 860 877 893 909 925 942 959 976 992 1010 1027 27.7 28.9 30.1 31.4 32.8 34.2 35.7 37.4 39.1 41.0 43.1 45.2 47.3 49.5 51.8 54.1 56.5 59.0 61.6 64.3 5 801 811 822 834 847 860 874 888 903 918 934 950 966 982 999 1016 1032 35.0 36.3 37.7 39.2 40.8 42.5 44.2 46.0 48.0 50.1 52.3 54.9 57.3 59.7 62.3 64.9 67.6 3 858 868 879 891 904 917 931 945 960 974 990 1006 1022 1038 42.9 44.4 46.1 47.8 49.6 51.5 53.4 55.5 57.7 60.0 62.5 65.1 68.1 70.8 Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent. Fan tables cover part of fan operating range; fan curves show full operating range. 46 903 912 922 934 946 959 972 985 1000 1014 1029 50.0 51.6 53.3 55.3 57.2 59.2 61.3 63.5 65.8 68.3 70.9 1 1/4” RPM BHP 482 493 505 519 533 548 563 580 596 613 630 647 664 682 700 718 736 755 776 792 7.6 8.1 8.7 9.3 9.9 10.6 11.4 12.3 13.2 14.2 15.2 16.2 17.4 18.5 19.8 21.1 22.5 24.0 25.6 27.2 5” RPM BHP 955 965 975 987 999 1012 1025 1039 59.3 61.1 63.0 65.2 67.4 69.6 72.0 74.4 1 1/2” RPM BHP 523 532 544 557 570 585 600 615 631 648 664 681 698 715 733 750 768 787 805 9.7 10.3 10.9 11.6 12.3 13.1 14.0 14.9 16.0 17.1 18.2 19.3 20.6 21.8 23.2 24.7 26.2 27.8 29.5 5 1/2” RPM BHP 997 1006 1016 1027 1039 67.3 69.2 71.3 73.5 75.9 1 3/4” 2” RPM BHP RPM BHP 570 581 593 606 620 634 650 665 681 698 714 731 748 765 782 800 818 12.6 13.3 14.1 14.9 15.7 16.7 17.7 18.8 20.1 21.3 22.6 24.0 25.4 26.9 28.4 30.1 31.8 606 616 628 641 654 668 683 698 714 730 746 763 780 797 814 831 15.1 15.9 16.8 17.7 18.6 19.6 20.8 22.0 23.3 24.7 26.0 27.6 29.2 30.8 32.4 34.2 6” 6 1/2” RPM BHP RPM BHP Performance Data Q Fan Size 60 ____ Fan RPM Line - - - Motor HP Line Standard fans can be selected ONLY in the shaded area. Thrust restrains are to be used with fans Class 3 or motors 40 hp and up. Super Q fans are NOT available in size 60. Horizontal fans only, for vertical units contact marketing in Lexington. Minimum and Maximum Motor HP Ranges Arrangement 9 Arrangement 1 Min - Max Motor HP Class 1 3 - 30 — Q Fan Size 60” Min - Max Motor HP Class 2 25 - 75 — Min - Max Motor HP Class 3 — — 47 Super Q Fan Size 60” Min - Max Min - Max Motor HP Motor HP Class 1 Class 2 NA NA NA NA Dimensional Data and Weights Roughing-In Dimensions Arrangement 9 Arrangement 9 Dimensions Size 16 16 16 19 19 19 21 21 21 24 24 24 27 27 27 30 30 30 33 33 33 36 36 36 40 40 40 44 44 44 Class I Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III In A 19 3/8 19 3/8 19 3/8 21 7/8 21 7/8 21 7/8 24 5/8 24 5/8 24 5/8 28 1/8 28 1/8 28 1/8 30 7/8 30 7/8 30 7/8 34 3/8 34 3/8 34 3/8 37 3/4 37 3/4 37 3/4 41 3/4 41 3/4 41 3/4 46 46 46 50 7/8 50 7/8 50 7/8 Out B 17 7/8 17 7/8 17 7/8 20 1/2 20 1/2 20 1/2 23 1/8 23 1/8 23 1/8 26 3/8 26 3/8 26 3/8 29 29 29 32 1/4 32 1/4 32 1/4 35 1/2 35 1/2 35 1/2 39 1/4 39 1/4 39 1/4 43 1/4 43 1/4 43 1/4 47 3/4 47 3/4 47 3/4 L 28 3/8 28 3/8 28 3/8 28 7/8 28 7/8 28 7/8 32 3/4 32 3/4 32 3/4 35 3/8 35 3/8 35 3/8 38 38 38 41 1/8 41 1/8 41 1/8 45 45 45 49 1/2 49 1/2 49 1/2 53 3/4 53 3/4 53 3/4 60 5/8 60 5/8 60 5/8 Approximate weights are without motor and drive. Motor position should be determined from the outlet side. 48 W 23 5/8 23 5/8 23 5/8 26 1/8 26 1/8 26 1/8 29 29 29 32 7/8 32 7/8 32 7/8 35 3/4 35 3/4 35 3/4 39 1/8 39 1/8 39 1/8 42 5/8 42 5/8 42 5/8 47 5/8 47 5/8 47 5/8 51 7/8 51 7/8 51 7/8 56 3/4 56 3/4 56 3/4 H Max. 45 45 45 48 1/4 48 1/4 48 1/4 51 3/8 51 3/8 51 3/8 55 1/4 55 1/4 55 1/4 58 1/8 58 1/8 58 1/8 61 5/8 61 5/8 61 5/8 65 1/8 65 1/8 65 1/8 69 5/8 69 5/8 69 5/8 77 77 77 82 82 82 Drive Shaft Dia. 15 /16 15 /16 1 3/16 15 /16 15 /16 1 3/16 15 /16 1 3/16 1 3/16 1 3/16 1 3/16 1 11/16 1 3/16 1 7/16 1 15/16 1 3/16 1 7/16 1 15/16 1 3/16 1 7/16 2 3/16 1 7/16 1 11/16 2 7/16 1 7/16 1 11/16 2 15/16 1 11/16 1 15/16 3 7/16 Unit Net Wt. Lbs. 115 115 120 135 135 140 175 180 185 215 220 225 275 290 305 350 360 375 440 450 485 575 580 630 710 720 800 830 850 950 Dimensional Data and Weights Roughing-In Dimensions Arrangement1 Arrangement 1 Dimensions Size 16 19 21 24 27 27 30 30 33 33 33 36 36 36 40 40 40 44 44 44 Class III Class III Class III Class III Class II Class III Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III Class I Class II Class III In A 19 3/8 21 7/8 24 5/8 28 1/8 30 7/8 30 7/8 34 3/8 34 3/8 37 3/4 37 3/4 37 3/4 41 3/4 41 3/4 41 3/4 46 46 46 50 7/8 50 7/8 50 7/8 Out B 17 7/8 20 1/2 23 1/8 26 3/8 29 29 32 1/4 32 1/4 35 1/2 35 1/2 35 1/2 39 1/4 39 1/4 39 1/4 43 1/4 43 1/4 43 1/4 47 3/4 47 3/4 47 3/4 L 28 3/8 28 7/8 32 3/4 35 3/8 38 38 41 1/8 41 1/8 45 45 45 49 1/2 49 1/2 49 1/2 53 3/4 53 3/4 53 3/4 60 5/8 60 5/8 60 5/8 W 23 5/8 26 1/8 29 32 7/8 35 3/4 35 3/4 39 1/8 39 1/8 42 5/8 42 5/8 42 5/8 47 5/8 47 5/8 47 5/8 51 7/8 51 7/8 51 7/8 56 3/4 56 3/4 56 3/4 H Max. 45 47 1/2 52 1/4 56 1/8 57 1/8 62 3/4 60 1/2 66 1/8 61 3/8 65 7/8 73 7/8 69 70 5/8 78 7/8 73 1/4 78 7/8 88 5/8 78 1/8 83 3/4 93 1/2 Drive Shaft Dia. 1 3/16 1 3/16 1 3/16 1 11/16 1 7/16 1 15/16 1 7/16 1 15/16 1 3/16 1 7/16 2 3/16 1 7/16 1 11/16 2 7/16 1 7/16 1 11/16 2 15/16 1 11/16 1 15/16 3 7/16 Unit Net Wt. Lbs. 120 140 185 225 290 305 360 375 440 450 485 575 580 630 710 720 800 830 850 950 Arrangement 1, Class I and II require an integral base (supplied by others). Class III should be mounted on an inertia pad (no integral base required with inertia pad). Approximate weights are without motor and drive. 49 Dimensional Data and Weights Roughing-In Dimensions Arrangement 9 Arrangement 9 Dimensions Size 49 49 54 54 60 60 Class I Class II Class I Class II Class I Class II A 52 3/8 52 3/8 58 58 64 1/8 64 1/8 L 76 76 81 7/8 81 7/8 92 92 Approximate weights are without motor and drive. 50 W 57 1/8 57 1/8 62 3/4 62 3/4 69 3/4 69 3/4 H Max. 79 7/8 85 1/2 85 1/2 91 1/4 96 1/4 108 1/4 Drive Shaft Dia. 1 11/16 2 3/16 1 15/16 2 7/16 2 3/16 2 11/16 Unit Net Wt. Lbs. 1020 1075 1090 1140 1730 1830 Dimensional Data and Weights Q Fan Accessory Dimensions Figure D-1 — Q Fan Inlet Vanes Table D-1 — Inlet Vane Dimensions Fan Size 16 19 21 24 27 30 33 36 40 44 49 54 60 A 19.562 22.062 24.875 28.312 31.125 34.562 38.000 42.062 46.312 51.188 52.562 58.250 64.250 C 11.625 12.500 12.375 12.000 12.375 12.375 12.813 14.250 17.250 18.438 18.188 19.000 20.750 Number Approx. of blades Wt. Lbs. 9 85 11 110 11 120 11 140 11 150 11 175 15 185 15 245 15 300 17 353 17 391 17 478 17 558 Figure D-2 — Q Fan Duct Outlet Diffuser, Sizes 16-44 Table D-2 — Outlet Diffuser (Equalizer) Dimensions ½” A 1” B D C E 51 Fan Size 16 19 21 24 27 30 33 36 40 44 A 17 7/8 20 1/2 23 1/4 26 3/8 29 1/8 32 1/4 35 1/2 39 1/4 43 1/4 47 3/4 B 19 1/4 21 5/8 24 1/2 27 7/8 30 3/4 34 1/4 37 5/8 41 5/8 45 7/8 50 3/4 C 3 3 1/2 4 4 1/2 5 5 1/2 6 6 5/8 7 3/8 8 1/8 D 1 1/8 1 1 1/4 1 1/8 1 1/8 1 1/4 1 1/4 1 1/4 1 1/8 1 1/4 E 5 1/8 5 1/2 6 1/8 6 5/8 7 7 3/4 8 1/4 8 7/8 9 3/8 10 3/8 Dimensional Data and Weights Q Fan Accessory Dimensions Figure D-3 — Super Q II 16-44 Sizes Table D-3 Unit Size 16 19 21 24 27 30 33 36 40 44 A 11 7/8 13 1/8 14 1/2 16 1/2 17 7/8 19 7/8 21 3/8 24 1/8 26 1/4 28 7/8 B 15 1/4 16 1/2 17 7/8 19 3/4 21 1/4 23 24 5/8 27 1/8 29 1/4 31 3/4 C 45 3/8 45 7/8 49 3/4 52 3/8 55 58 1/8 61 7/8 66 1/2 70 3/4 77 5/8 D 28 30 1/2 33 3/8 37 1/4 40 1/8 43 3/4 47 1/8 53 56 1/2 62 1/4 E 20 1/8 22 1/8 26 1/8 28 1/8 32 1/8 34 1/8 38 1/8 42 1/8 46 1/8 52 1/8 Inlet Area Sq. Ft. 2.2 2.6 3.7 4.3 5.6 6.3 7.9 9.2 11.6 14.9 F 17 7/8 19 7/8 22 7/8 25 7/8 28 7/8 31 7/8 35 7/8 39 7/8 43 7/8 47 7/8 * Approximate weights are without motor and drive. 52 Outlet Area Sq. Ft. 1.8 2.2 2.9 3.7 4.6 5.6 7.0 8.7 10.6 12.6 G 24 26 30 32 36 38 42 46 50 56 H 30 32 1/2 35 3/8 39 1/4 42 1/8 45 3/4 49 1/8 55 58 1/2 64 1/4 L 39 1/2 40 43 7/8 46 3/8 49 1/8 52 1/4 56 60 5/8 64 7/8 71 3/4 W 44 1/4 46 7/8 50 55 57 7/8 63 1/2 70 1/2 75 1/4 81 7/8 86 3/4 Unit Weights* 411 451 537 634 742 881 1048 1375 1567 1858 Dimensional Data and Weights Q Fan Accessory Dimensions fFigure D-4 — Q Fan/Super Q II Plus Outlet Silencers Table D-4 — Short Outlet Plus Silencer Fan Size 16” 19” 21” 24” 27” 30” 33” 36” 40” 44” 49” 54” 60” D 18” 20” 23” 26” 29” 32” 36” 40” 44” 48” 52” 58” 64” B 26” 28” 31” 34” 37” 40” 44” 48” 52” 56” 60” 66” 72” L 18” 20” 23” 26” 29” 32” 36” 40” 44” 48” 52” 58” 64” Approx. Weight 68 82 102 130 166 182 260 315 426 534 652 850 1050 Note: Silencer center body is adjustable. D dimension is nominal duct size on entering air end and fitting size on leaving air end. Table D-5 — Long Outlet Plus Silencer Fan Size 16” 19” 21” 24” 27” 30” 33” 36” 40” 44” 49” 54” 60” D 18” 20” 23” 26” 29” 32” 36” 40” 44” 48” 52” 58” 64” B 26” 28” 31” 34” 37” 40” 44” 48” 52” 56” 60” 66” 72” L 36” 40” 46” 52” 58” 64” 72” 80” 88” 96” 104” 116” 128” Approx. Weight 136 164 204 260 332 364 520 630 852 1068 1304 1700 2100 Note: Silencer center body is adjustable. D dimension is nominal duct size on entering air end and fitting size on leaving air end. Figure D-5 — Q Fan/Super Q II Plus Inlet Silencers Table D-6 — Short Inlet Plus Silencer Fan Size 16” 19” 21” 24” 27” 30” 33” 36” 40” 44” 49” 54” 60” D 20” 22” 26” 28” 32” 34” 38” 42” 46” 52” 52” 58” 64” B 28” 30” 34” 36” 40” 42” 46” 50” 54” 60” 60” 66” 72” L 20” 22” 26” 28” 32” 34” 38” 42” 46” 52” 52” 58” 64” Approx. Weight 49 59 85 98 128 148 185 228 317 378 444 680 852 Note: Silencer center body is fixed in position. 53 Table D-7 — Long Inlet Plus Silencer Fan Size 16” 19” 21” 24” 27” 30” 33” 36” 40” 44” 49” 54” 60” D 20” 22” 26” 28” 32” 34” 38” 42” 46” 52” 52” 58” 64” B 28” 30” 34” 36” 40” 42” 46” 50” 54” 60” 60” 66” 72” L 40” 44” 52” 56” 64” 68” 76” 84” 92” 104” 104” 116” 128” Approx. Weight 97 117 170 196 256 296 370 455 634 755 888 1359 1704 Note: Silencer center body is fixed in position. Mechanical Specifications Q FAN ASSEMBLY Housing Housings are 14-gauge steel hydraulically expanded to form integral inlet bell and diffuser sections. Hydraulically expanded stiffening ring welded in area of wheel raceway. On VAV variable speed fan units, fan inlet supports are structurally reinforced to handle extra stresses of variable speed fan modulation and fan is balanced at ten different fan speeds over the desired operating range. Inlet/Outlet Shells Fan has tapered inlet and outlet shells over fan hub assembly. Shells uniformly accelerate air through blade area. End bell covers fan drive assembly, thereby reducing flow turbulence. Eight fan blades are precision aluminum casting with airfoil cross sections. Blade to shell clearance is in the range of 30 mils. Fan Wheel Fans size 16-44 have fan wheel of precision aluminum casting with eight radially projected blades with air-foil cross sections. Fans size 49-60 have fan wheel of sixteen precision cast and machined aluminum blades mounted on a steel wheel plate. All wheels are dynamically balanced and keyed to fan shaft. Diffuser Cast aluminum diffuser with 29 radially projected straightening vanes with airfoil cross sections. Leading edge of vanes are curved to reduce tone noise generation. Clips on almost every other vane eliminate harmonic ring potential. Shaft Solid AISI-C1040 hot-rolled steel, turned and polished. Close tolerances maintained where shaft makes contact with bearings. Bearings Precision, flange-mounted, self-aligning ball bearings at inlet and discharge. Bearings on all sizes are grease lubricated and selected for a minimum average life (AFBMA L-50) in excess of 200,000 hours at maximum cataloged operating conditions. Bearing greaselines are extended out through fan shell for easy servicing. Drives Mechanical drives are computer selected for low noise, low maintenance operation. Center distance and arc of contact is maintained within prefixed limits. Constant speed fans use variable or constant pitch drives; variable speed modulated fans use fixed drives only. SUPER QUIET II FANS Trane Super Quiet II (SQ2) fans include fan housing, wheel, shaft, bearings, diffuser section, motor mounting support, ODP standard or high efficiency motor, drives, spring isolation in acoustically-treated casing in a factory-assembled unit. Fan motors are outside of airstream. Constant volume units (SQ2C) are equipped with variable or constant pitch drives. Variable air volume units (SQ2V) use adjustable frequency inverters for fan capacity modulation and must have constant pitch drives. Inlet vanes are NOT available for Super Q II fans. ENCLOSURE Fans are internally isolated on four height saving spring isolators and then flex connected inside of an airtight acoustical enclosure. Walls are 16-gauge steel, internally lined with two-inch thick three-pound per square foot density fiberglass. Airside surface of acoustical lining is coated with black matte faced lining to prevent scuffing. Enclosure has two large full size side access panels. Access panels are fully gasketed and mechanically attached to casing for easy removal. Enclosure has access panel positioning feet to insure easy access panel replacement after removal. Duct connections in enclosure end panels slip connect to standard U.S. round duct sizes. Fan grease lines are extended through enclosure for easy servicing of fan. Optional fan motor leads are extended through casing for easier installation. Two rails support the entire enclosure. Rails can be rested on floor or hung from the ceiling with steel rods. Ducts can be directly connected to enclosure since fan is internally isolated. Enclosure is rated for four-inch negative or five-inch positive pressure. 54 Mechanical Specifications ACCESSORIES Inlet Screen (Q, SQ2) Heavy-gauge steel wire mesh. Inlet Bellmouth (Q, SQ2) On unducted inlets, the radius bellmouth uniformly accelerates air into the fan, reducing noise and energy requirements. Plus Duct Silencer (Q, SQ2) Significantly attenuates fan airborne sound levels. Center body of round silencer is dimensional matched to Q-fan hub. Center body is field adjustable in the direction of airflow. This allows hub to be located close to Q-fan, thereby reducing flow generated turbulence and noise. Silencers can be on inlet and/or outlet and come in short and long length versions. Silencers are flex connected to Q fans and slip connected directly to Super Q II enclosures. Silencers are shipped loose for field installation. Inlet Flange (Q) Rolled steel ring, factory-mounted, for flanged duct connection. Sizes 16 to 21 one-inch flanges, sizes 27 to 44 are 1½-inch flanges. Adjustable Inlet Vanes 11 steel vanes operated by a positive peripheral control mechanism located out of the airstream. Each vane is supported at both ends by a precision bronze bearing. The control arm is suitable for manual or automatic operation. Inlet vanes are shipped loose for field installation. 55 Outlet Flange (Q) Rolled steel ring, factory-mounted, for flanged duct connection. Outlet Diffuser (Equalizer) (Q) Steel spinning with 30 degree included diffusion angle. Permit same size slipduct connection on discharge as inlet. Outlet Screen (Q) Heavy-gauge steel wire mesh. Outlet Flow Stabilization Screen (Q, SQ2) Similar to outlet screen, but openings are much smaller. Designed to act as an airflow stabilization device on the outlet of each fan. The Trane Company An American Standard Company www.trane.com For more information contact your local sales office or e-mail us at comfort@trane.com Since The Trane Company has a policy of continuous product improvement, it reserves the right to change design and specification without notice. Library Product Section Product Model Literature Type Sequence Date File No. Supersedes Ordering No. Product Literature Air Handling Fans 000 Data Sales Catalog 2 August 2000 PL-AH-FAN-000-DS-2-0800 FAN-DS-2 597 FAN-DS-2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2000:08:16 13:53:21 Producer : Acrobat Distiller 4.05 for Windows Subject : 35376_fands2 Title : 35376_fands2 Author : inlandprep3 Creator : Adobe PageMaker 6.52 Modify Date : 2000:08:16 13:57:38-05:00 Page Count : 56 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools