UPFLOW/HORIZONTAL
2-STAGE, VARIABLE SPEED
GAS-FIRED FURNACE

XV80

MODELS
TUD2B060A9V3VB, TUD2B080A9V3VB
TUD2C080A9V4VB, TUD2C080B9V4VB
TUD2B100A9V3VB, TUD2C100A9V5VB
TUD2C100B9V5VB, TUD2D120A9V5VB
TUD2D120B9V5VB, TUD2D140A9V5VB
Two-Stage FanAssisted
CombustionSystem

PUB. NO. 22-1650-13

© 2011 Trane

General
Features
NATURAL GAS MODELS
Central Heating furnace designs are certified by the American Gas Association
for both natural and L.P. gas. Limit setting
and rating data were established and
approved under standart rating conditions using American National Standards
Instirute standards.
SAFE OPERATION
The Integrated System Control has solid
state devices, which continuously monitor
for presence of flame, when the system
is in the heaating mode of operation.
Dual solenoid combination gas valve and
regulator provide extra safety.
QUICK HEATING
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger quickly
transfers heat to provide warm conditioned air to the structure. Low energy
power vent blower, to increase efficiency
and provide a positive discharge of gas
fumes to the outside.
BURNERS
Multiport In-shot burners will give years
of quiet and efficient service. All models
can be converted to L.P. gas.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program
provides total control of furnace limit
sensors, blowers, gas valve, flame control
and includes self diagnostics for ease of
service. Also contains connection points
for E.A.C./humidifier.

© 2011 Trane

2

AIR DELIVERY
The variable speed, direct drive blower
motor, has sufficient airflow for most
heating and cooling requirements, will
switch from heating to cooling speeds
on demand from room thermostat. The
blower door safety switch will prevent or
terminate furnace operation when the
blower door is removed. Some models
are available with high efficiency blowers.
STYLING
Heavy gauge steel and “wrap-around”
cabinet construction is used in the
cabinet with baked-on enamel finish for
strength and beauty. The heat exchanger
section of the cabinet is completely
lined with foil faced fiberglass insulation.
This results in quiet and efficient operation due to the excellent acoustical and
insulating qualities of fiberglass. Built-in
bottom pan and alternate bottom, left or
right side return air connection provision.
FEATURES AND GENERAL OPERATION
The XV80 High Efficiency Gas Furnaces
employ a Hot Surface Ignition system,
which eliminates the waste of a constant
burning pilot. The integrated system
control lights the main burners upon a demand for heat from the room thermostat.
Complete front service access.
a. Low energy power venter
b. Vent proving pressure switch.

22-1650-13

Contents

Feature Summary	

2	

Features and Benefits	

4	

Standard Equipment
Optional Equipment

General Data	

22-1650-13

4
5

6	

	TUD2B060A9V3VB
	TUD2B080A9V3VB
	TUD2C080A9V4VB
	TUD2C080B9V4VB
	TUD2B100A9V3VB
	TUD2C100A9V5VB
	TUD2C100B9V5VB
	TUD2D120A9V5VB
	TUD2D120B9V5VB
	TUD2D140A9V5VB
	

	
	
	
	
	
	
	
	
	
	
	

Performance Data	

9	

Electric Data	

19	

Field Wiring Diagrams	

19	

Dimensions	

24	

3

Features
and Benefits
XV80 STANDARD EQUIPMENT
•	Upflow/Horizontal and
•	Power supply 115/1/60
•	2-stage gas valve
•	2-speed venter
•	Variable speed blower motor
•	Silicon Nitride hot surface igniter with
adaptive heat up
•	Integrated solid state control
•	Attractive color accents
•	Heavy gauge aluminized steel heat
exchanger
•	Multi-port In-shot burners
•	Complete front service access
•	Alternate bottom/left/right return air
•	Slide out blower assembly
•	Hinged blower door
•	Perfect fit door catches

4

•	Insulated blower door
•	Gasketed blower door
•	Internal filter rack
•	Standard filter sizes
•	Two-tone color
•	Direct drive, variable speed motor
•	Integrated solid state control with
	self-diagnostics
•	Common vent capability
•	Cleanable framed filters
•	Optional L.P. conversion kit
•	Left/right gas connection
•	Accessory hook-up capability
• 	Selectable cooling fan off delay
­eliminates need for BAY24X045 time
delay kit
•	Enhanced cooling control

22-1650-13

Features
and Benefits
XV80 OPTIONAL EQUIPMENT
Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling......................................................................................... TAYSTAT241 [ 
Thermostat, Mechanical Heating Only With Fan Switch.............................................................................................. BAYSTAT303 [ 
Thermostat, Mechanical Heating Only........................................................................................................................ BAYSTAT388 [ 
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ..................................................................................AY28X092 [ 
Thermostat, Electronic Non-programmable 1-Stage Heating/1-Stage Cooling........................................................... BAYSTAT370 [ 
Thermostat, Electronic Programmable (5-2) 1-Stage Heating/1-Stage Cooling.......................................................... BAYSTAT340 [ 
Thermostat, Heating/Cooling Single Stage (Mounts Vertically)................................................................................... BAYSTAT305 [ 
Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling................................................................ TAYSTAT302C [ 
Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling................................................................ TAYSTAT300C [ 
Propane Conversion Kit............................................................................................................................................ BAYLPKT210A [ 
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace)......................................................... TFM175A9FR0 [ 
Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace)............................................................... TFM210A9FR0 [ 
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace)......................................................... TFM245A9FR0 [ 
Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace)..................................................TFP175A9FR0 [ 
Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace).........................................................TFP210A9FR0 [ 
Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace)..................................................TFP245A9FR0 [ 
Coil Enclosure (17-1/2" Wide Cabinets)............................................................................................................. BAYCLE17A1722A [ 
Coil Enclosure (21" Wide Cabinets)................................................................................................................... BAYCLE21A2130A [ 
Coil Enclosure (24-1/2" Wide Cabinets)............................................................................................................. BAYCLE24A2430A [ 
Side Filter Rack........................................................................................................................................................... BAYFLTR200 [ 
High Altitude Switch..................................................................................................................................................... BAYHALT249 [ 
Masonry Chimney Vent Kit (Upflow models only).....................................................................................................BAYVENT800B [ 
Filter Rack Kit 1 ..................................................................................................................................................... BAYRACK960A [ 
1	Available for models with 1800 CFM or greater which require an additional side return.

22-1650-13

5

]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]

GENERAL DATA

TUD-R9V PRODUCT SPECIFICATIONS1
MODEL
TYPE
RATINGS 2
1st Stage Input BTUH
  1st Stage Capacity BTUH (ICS) 3
2nd Stage Input BTUH
  2nd Stage Capacity BTUH (ICS) 3
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGER
Type	-Fired
	-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L. P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (In.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs.)

TUD2B060A9V3VB

TUD2B080A9V3VB

TUD2C080A9V4VB

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

39,000
31,200
60,000
48,000
30 - 60

52,000
41,600
80,000
64,000
30 - 60

52,000
41,600
80,000
64,000
30 - 60

Direct
10 x 7
1
Variable
See Airflow Table
1/2
Variable
115/1/60

Direct
10 x 7
1
Variable
See Airflow Table
1/2
Variable
115/1/60

Direct
10 x 10
1
Variable
See Airflow Table
3/4
Variable
115/1/60

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.7

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.7

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.7

Yes
High Velocity
1 - 17x25 - 1in.

Yes
High Velocity
1 - 17x25 - 1in.

Yes
High Velocity
1 - 20x25 - 1in.

4 Round

4 Round

4 Round

Alum. Steel - Type 1

Alum. Steel - Type 1

Alum. Steel - Type 1

20

20

20

3 — 45
3 — 56

4 — 45
4 — 56

4 — 45
4 — 56

Redundant - Two Stage

Redundant - Two Stage

Redundant - Two Stage

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

Multi-port In-shot
3

Multi-port In-shot
4

Multi-port In-shot
4

115/1/60
10.5
15

115/1/60
10.5
15

115/1/60
12.9
20

1/2

1/2

1/2

HxWxD
41-3/4 x 19-1/2 x 30-1/2

HxWxD
41-3/4 x 19-1/2 x 30-1/2

HxWxD
41-3/4 x 23 x 30-1/2

136 / 126

142 / 132

166 / 155

1	 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2	 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3	 Based on U.S. government standard tests.
4	 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

6	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

TUD-R9V PRODUCT SPECIFICATIONS1
MODEL
TYPE
RATINGS 2
1st Stage Input BTUH
  1st Stage Capacity BTUH (ICS) 3
2nd Stage Input BTUH
  2nd Stage Capacity BTUH (ICS) 3
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGER
Type	-Fired
	-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L. P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (In.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs.)

TUD2C080B9V4VB 5

TUD2B100A9V3VB

TUD2C100A9V5VB

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

52,000
41,600
80,000
64,000
30 - 60

65,000
52,000
100,000
80,000
40 - 70

65,000
52,000
100,000
79,000
35 - 65

Direct
10 x 10
1
Variable
See Airflow Table
3/4
Variable
115/1/60

Direct
10 x 7
1
Variable
See Airflow Table
1/2
Variable
115/1/60

Direct
10 x 10
1
Variable
See Airflow Table
1
Variable
115/1/60

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.7

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.87

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.87

Yes
High Velocity
1 - 20x25 - 1in.

Yes
High Velocity
1 - 17x25 - 1in.

Yes
High Velocity
1 - 20x25 - 1in.

4 Round

4 Round

4 Round

Alum. Steel - Type 1

Alum. Steel - Type 1

Alum. Steel - Type 1

20

20

20

4 — 45
4 — 56

5 — 45
5 — 56

5 — 45
5 — 56

Redundant - Two Stage

Redundant - Two Stage

Redundant - Two Stage

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

Multi-port In-shot
4

Multi-port In-shot
5

Multi-port In-shot
5

115/1/60
12.9
20

115/1/60
10.8
15

115/1/60
14.9
20

1/2

1/2

1/2

HxWxD
41-3/4 x 23 x 30-1/2

HxWxD
41-3/4 x 19-1/2 x 30-1/2

HxWxD
41-3/4 x 23 x 30-1/2

166 / 155

142 / 132

166 / 155

1	 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2	 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3	 Based on U.S. government standard tests.
4	 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5	 Model uses high efficiency blower.

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

7

TUD-R9V PRODUCT SPECIFICATIONS1
MODEL

TUD2C100B9V5VB 5

TUD2D120A9V5VB

TUD2D120B9V5VB 5

TUD2D140A9V5VB

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

Upflow / Horizontal

65,000
52,000
100,000
79,000
35 - 65

78,000
62,400
120,000
97,000
35 - 65

78,000
62,400
120,000
97,000
35 - 65

91,000
72,800
140,000
111,000
40 - 70

Direct
10 x 10
1
Variable
See Airflow Table
1
Variable
115/1/60

Direct
10 x 10
1
Variable
See Airflow Table
1
Variable
115/1/60

Direct
10 x 10
1
Variable
See Airflow Table
1
Variable
115/1/60

Direct
10 x 10
1
Variable
See Airflow Table
1
Variable
115/1/60

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.87

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
1.14

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
1.14

Centrifugal
Direct - 2
1/50 - 3000
115/1/60
1.16

Yes
High Velocity
1 - 20x25 - 1in.

Yes
High Velocity
1 - 24x25 - 1in.

Yes
High Velocity
1 - 24x25 - 1in.

Yes
High Velocity
1 - 24x25 - 1in.

4 Round

4 Round

4 Round

4 Round

Alum. Steel - Type 1

Alum. Steel - Type 1

Alum. Steel - Type 1

Alum. Steel - Type 1

20

20

20

20

5 — 45
5 — 56

6 — 45
6 — 56

6 — 45
6 — 56

7 — 45
7 — 56

Redundant - Two Stage

Redundant - Two Stage

Redundant - Two Stage

Redundant - Two Stage

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

Hot Surface Ignition

Multi-port In-shot
5

Multi-port In-shot
6

Multi-port In-shot
6

Multi-port In-shot
7

115/1/60
14.9
20

115/1/60
15.3
20

115/1/60
15.3
20

115/1/60
15.3
20

TYPE
RATINGS 2
1st Stage Input BTUH
  1st Stage Capacity BTUH (ICS) 3
2nd Stage Input BTUH
  2nd Stage Capacity BTUH (ICS) 3
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGER
Type	-Fired
	-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L. P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (In.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs.)

1/2

1/2

1/2

1/2

HxWxD
41-3/4 x 23 x 30-1/2

HxWxD
41-3/4 x 26-1/2 x 30-1/2

HxWxD
41-3/4 x 26-1/2 x 30-1/2

HxWxD
41-3/4 x 26-1/2 x 30-1/2

166 / 155

193 / 181

193 / 181

197 / 185

1	 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2	 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3	 Based on U.S. government standard tests.
4	 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5	 Model uses high efficiency blower.

8	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

*UD2B060A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW7

EXTERNAL STATIC PRESSURE

SW8

0.1

0.3

0.5

0.7

0.9

589
49
65

604
48
95

619
47
125

604
48
160

607
48
200

LOW

ON

ON

CFM
TEMP. RISE
WATTS

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

663
44
75

694
42
120

684
42
145

681
42
185

686
42
220

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

775
37
105

781
37
145

776
37
180

805
36
230

811
36
270

LOW

ON

ON

CFM
TEMP. RISE
WATTS

813
55
110

818
54
150

818
54
185

837
53
240

842
53
280

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

907
49
140

919
48
200

942
47
240

958
46
300

959
46
330

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1038
43
190

1066
42
260

1086
41
325

1089
41
365

1079
41
415

*UD2B060A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

1.5

2

2.5

3 **

AIRFLOW
SETTING

DIP SWITCH SETTING
SW1

SW2

SW3

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

ON

CFM
WATTS

499
50

537
80

520
110

520
145

500
175

OFF

OFF

CFM
WATTS

605
60

610
80

610
120

597
155

593
180

ON

ON

OFF

CFM
WATTS

649
75

681
110

665
145

665
180

672
220

OFF

ON

OFF

ON

CFM
WATTS

680
80

722
125

680
150

696
190

696
225

NORMAL
(400 CFM/ TON)

OFF

ON

OFF

OFF

CFM
WATTS

798
105

804
145

809
170

823
235

818
280

HIGH
(450 CFM/ TON)

OFF

ON

ON

OFF

CFM
WATTS

884
145

896
180

924
240

931
280

931
330

LOW
(350 CFM/ TON)

ON

OFF

OFF

ON

CFM
WATTS

858
125

863
175

882
220

894
275

895
320

NORMAL
(400 CFM/ TON)

ON

OFF

OFF

OFF

CFM
WATTS

984
170

1017
225

1038
295

1017
330

1017
375

HIGH
(450 CFM/ TON)

ON

OFF

ON

OFF

CFM
WATTS

1125
245

1138
315

1150
370

1161
435

1161
475

LOW
(350 CFM/ TON)

OFF

OFF

OFF

ON

CFM
WATTS

1035
205

1056
265

1076
330

1076
370

1076
430

NORMAL **
(400 CFM/ TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1208
300

1247
360

1268
440

1278
485

1200
490

HIGH
(450 CFM/ TON)

OFF

OFF

ON

OFF

CFM
WATTS

1380
440

1410
500

1402
550

1350
550

1235
525

LOW
(350 CFM/ TON)

ON

ON

OFF

NORMAL
(400 CFM/ TON)

ON

ON

HIGH
(450 CFM/ TON)

ON

LOW
(350 CFM/ TON)

SW4

NOTES:
1. *FIRST LETTER MAY BE "A" OR "T"
2. **FACTORY SETTING.
3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING:
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

9

*UD2B080A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW 7

EXTERNAL STATIC PRESSURE

SW 8

0.1

0.3

0.5

0.7

0.9

800
48
100

790
49
135

765
50
155

750
52
200

730
53
230

LOW

ON

ON

CFM
TEMP. RISE
WATTS

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

910
43
130

890
44
170

875
44
210

860
45
240

820
47
280

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1060
37
188

1020
38
220

1010
39
265

1010
39
310

1000
39
350

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1110
54
210

1090
55
260

1090
55
310

1080
55
350

1065
56
400

ON

OFF

CFM
TEMP. RISE
WATTS

1245
48
300

1240
48
355 

1240
48
410

1230
48
460

1215
49
500

OFF

OFF

CFM
TEMP. RISE
WATTS

1415
42
410

1400
42
470

1400
42
530

1375
43
580

1320
45
590

MEDIUM **

HIGH

*UD2B080A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

2.5

3.0

3.5 **

AIRFLOW
SETTING

DIP SWITCH SETTING
SW 1

SW 2

SW 3

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

ON

CFM
WATTS

880
120

875
155

860
190

845
225

840
245

OFF

OFF

CFM
WATTS

1020
170

1000
205

990
240

980
280

960
320

ON

ON

OFF

CFM
WATTS

1110
210

110
260

1110
320

1100
350

1100
385

ON

OFF

OFF

ON

CFM
WATTS

1040
190

1010
220

1000
260

1000
310

990
340

NORMAL
(400 CFM/TON)

ON

OFF

OFF

OFF

CFM
WATTS

1200
250

1200
320

1190
370

1190
415

1175
450

HIGH
(450 CFM/TON)

ON

OFF

ON

OFF

CFM
WATTS

1340
355

1340
425

1330
475

1320
530

1300
570

LOW
(350 CFM/TON)

OFF

OFF

OFF

ON

CFM
WATTS

1215
265

1210
330

1210
375

1200
430

1185
465

NORMAL **
(400 CFM/TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1430
415

1415
457

1410
520

1385
575

1330
580

HIGH
(450 CFM/TON)

OFF

OFF

ON

OFF

CFM
WATTS

1430
415

1415
475

1410
520

1385
575

1330
580

LOW
(350 CFM/TON)

OFF

ON

OFF

NORMAL
(400 CFM/TON)

OFF

ON

HIGH
(450 CFM/TON)

OFF

LOW
(350 CFM/TON)

SW 4

NOTES:
1. * First Letter may be "A" or "T"
2. ** Factory setting
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting

10	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

*UD2C080A9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW 7

EXTERNAL STATIC PRESSURE

SW 8

0.1

0.3

0.5

0.7

0.9

782
49
75

762
51
110

751
51
145

748
51
185

737
52
225

LOW

ON

ON

CFM
TEMP. RISE
WATTS

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

870
44
90

865
45
125

861
45
175

848
45
215

831
46
255

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

962
40
110

974
40
155

963
40
200

938
41
245

914
42
290

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1091
54
145

1092
54
190

1087
55
245

1092
54
305

1077
55
355

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1211
49
190

1243
48
255

1243
48
310

1244
48
370

1235
48
430

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1371
43
255

1388
43
325

1392
43
395

1385
43
455

1377
43
515

*UD2C080A9V4VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

2.5

3.0

3.5

4 **

AIRFLOW
SETTING

DIP SWITCH SETTING
SW 1

SW 2

SW 3

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

ON

CFM
WATTS

863
90

865
130

858
175

843
220

831
255

OFF

OFF

CFM
WATTS

995
115

1005
170

989
210

973
260

956
305

ON

ON

OFF

CFM
WATTS

1101
150

1112
200

1111
255

1107
305

1101
360

OFF

ON

OFF

ON

CFM
WATTS

1031
125

1031
175

1026
215

1013
270

1003
320

NORMAL
(400 CFM/TON)

OFF

ON

OFF

OFF

CFM
WATTS

1163
170

1178
230

1188
285

1183
345

1178
405

HIGH
(450 CFM/TON)

OFF

ON

ON

OFF

CFM
WATTS

1319
240

1337
305

1344
365

1340
420

1336
485

LOW
(350 CFM/TON)

ON

OFF

OFF

ON

CFM
WATTS

1182
200

1206
240

1211
295

1211
350

1211
420

NORMAL
(400 CFM/TON)

ON

OFF

OFF

OFF

CFM
WATTS

1380
255

1401
325

1402
390

1402
460

1399
515

HIGH
(450 CFM/TON)

ON

OFF

ON

OFF

CFM
WATTS

1553
350

1566
425

1557
500

1558
560

1559
645

LOW
(350 CFM/TON)

OFF

OFF

OFF

ON

CFM
WATTS

1386
255

1401
330

1408
395

1402
460

1390
520

NORMAL **
(400 CFM/TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1590
360

1593
440

1591
515

1588
575

1576
650

HIGH
(450 CFM/TON)

OFF

OFF

ON

OFF

CFM
WATTS

1791
360

1808
615

1810
615

1808
775

1726
800

LOW
(350 CFM/TON)

ON

ON

OFF

NORMAL
(400 CFM/TON)

ON

ON

HIGH
(450 CFM/TON)

ON

LOW
(350 CFM/TON)

SW 4

NOTES:
1. * First Letter may be "A" or "T"
2. ** Factory setting
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

11

*UD2C080B9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW 7

EXTERNAL STATIC PRESSURE

SW 8

0.1

0.3

0.5

0.7

0.9

974
49
133

968
49
285

949
50
202

925
51
254

906
52
304

LOW

ON

ON

CFM
TEMP. RISE
WATTS

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1102
43
93

1112
43
144

1103
43
201

1083
44
255

1066
45
305

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1194
40
119

1217
39
180

1215
39
243

1200
40
304

1182
40
362

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1189
58
142

1210
57
209

1209
57
276

1193
58
341

1175
58
404

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1346
51
141

1388
49
207

1398
49
274

1390
49
339

1372
50
401

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1460
47
186

1516
45
263

1536
45
335

1533
45
407

1515
45
477

*UD2C080B9V4VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

2.5

3.0

3.5

4 **

AIRFLOW
SETTING

DIP SWITCH SETTING

EXTERNAL STATIC PRESSURE

SW 1

SW 2

SW 3

SW 4

0.1

0.3

0.5

0.7

0.9

LOW
(350 CFM/TON)

ON

ON

OFF

ON

CFM
WATTS

842
71

819
114

789
163

756
207

740
249

NORMAL
(400 CFM/TON)

ON

ON

OFF

OFF

CFM
WATTS

956
90

948
140

928
196

901
248

884
298

HIGH
(450 CFM/TON)

ON

ON

ON

OFF

CFM
WATTS

1071
113

1078
171

1067
233

1045
292

1028
348

LOW
(350 CFM/TON)

OFF

ON

OFF

ON

CFM
WATTS

1002
99

1000
152

983
210

958
265

942
318

NORMAL
(400 CFM/TON)

OFF

ON

OFF

OFF

CFM
WATTS

1140
128

1155
191

1150
256

1132
319

1114
379

HIGH
(450 CFM/TON)

OFF

ON

ON

OFF

CFM
WATTS

1278
165

1311
238

1316
308

1305
377

1287
444

LOW
(350 CFM/TON)

ON

OFF

OFF

ON

CFM
WATTS

1163
134

1181
199

1177
265

1161
328

1143
389

NORMAL
(400 CFM/TON)

ON

OFF

OFF

OFF

CFM
WATTS

1324
179

1363
255

1372
326

1363
397

1345
466

HIGH
(450 CFM/TON)

ON

OFF

ON

OFF

CFM
WATTS

1485
234

1544
319

1566
396

1565
472

1546
550

LOW
(350 CFM/TON)

OFF

OFF

OFF

ON

CFM
WATTS

1324
179

1363
255

1372
326

1363
397

1345
466

NORMAL **
(400 CFM/TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1508
243

1570
329

1594
407

1593
483

1575
562

HIGH
(450 CFM/TON)

OFF

OFF

ON

OFF

CFM
WATTS

1691
322

1777
416

1816
499

1824
579

1805
669

NOTES:
1. * First Letter may be "A" or "T"
2. ** Factory setting
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting

12	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

*UD2B100A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW 7

SW 8

LOW

ON

ON

MEDIUM **

ON

HIGH

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

CFM
TEMP. RISE
WATTS

751
64
86

796
61
132

817
59
175

832
58
218

838
57
263

OFF

CFM
TEMP. RISE
WATTS

862
56
121

921
52
185

953
51
233

967
50
285

954
50
322

OFF

OFF

CFM
TEMP. RISE
WATTS

959
50
148

1002
48
210

1036
46
280

1036
46
325

1003
48
355

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1099
67
227

1124
66
287

1149
64
355

1157
64
415

1055
70
395

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1286
58
365

1321
56
450

1313
56
455

1215
61
475

1119
66
450

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1399
53
465

1419
52
570

1347
55
545

1265
59
520

1163
64
485

*UD2B100A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

1.5

2.0

2.5

3.0**

AIRFLOW
SETTING

DIP SWITCH SETTING
SW 1

SW 2

SW 3

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

ON

CFM
WATTS

516
50

536
75

551
105

547
135

530
165

OFF

OFF

CFM
WATTS

583
59

615
92

633
127

621
157

618
18

ON

ON

OFF

CFM
WATTS

681
70

697
110

701
140

709
180

712
215

OFF

ON

OFF

ON

CFM
WATTS

680
75

726
120

735
150

741
190

745
230

NORMAL
(400 CFM/TON)

OFF

ON

OFF

OFF

CFM
WATTS

769
103

819
145

843
190

858
235

865
286

HIGH
(450 CFM/TON)

OFF

ON

ON

OFF

CFM
WATTS

882
130

938
190

961
245

975
300

970
345

LOW
(350 CFM/TON)

ON

OFF

OFF

ON

CFM
WATTS

831
180

903
180

928
230

935
275

935
320

NORMAL
(400 CFM/TON)

ON

OFF

OFF

OFF

CFM
WATTS

979
167

1036
240

1053
295

1053
345

1015
368

HIGH
(450 CFM/TON)

ON

OFF

ON

OFF

CFM
WATTS

1121
245

1147
310

1176
383

1167
442

1055
396

LOW
(350 CFM/TON)

OFF

OFF

OFF

ON

CFM
WATTS

1061
210

1081
265

1095
320

1101
382

1032
380

NORMAL **
(400 CFM/TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1185
278

1223
364

1251
435

1205
455

1101
426

HIGH
(450 CFM/TON)

OFF

OFF

ON

OFF

CFM
WATTS

1351
425

1372
503

1343
535

1248
505

1168
480

LOW
(350 CFM/TON)

ON

ON

OFF

NORMAL
(400 CFM/TON)

ON

ON

HIGH
(450 CFM/TON)

ON

LOW
(350 CFM/TON)

SW 4

NOTES:
1. * First Letter may be "A" or "T"
2. ** Factory setting
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

13

*UD2C100A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW 7

SW 8

LOW

ON

ON

MEDIUM **

ON

HIGH

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

CFM
TEMP. RISE
WATTS

900
53
100

890
54
130

870
55
175

850
57
220

835
58
270

OFF

CFM
TEMP. RISE
WATTS

1125
43
150

1090
44
200

1060
46
235

1070
45
300

1070
45
340

OFF

OFF

CFM
TEMP. RISE
WATTS

1300
37
220

1300
37
290

1320
36
365

1350
36
430

1340
36
490

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1270
59
200

1290
58
260

1290
58
335

1290
58
400

1280
58
460

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1575
47
355

1600
46
445

1610
46
520

1600
46
575

1580
47
650

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1870
40
560

1890
39
665

1860
40
710

1870
40
830

1730
43
760

*UD2C100A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

3.0

3.5

4.0

5.0 **

AIRFLOW
SETTING

DIP SWITCH SETTING
SW 1

SW 2

SW 3

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

ON

CFM
WATTS

1075
135

1055
185

1015
220

1000
265

990
325

OFF

OFF

CFM
WATTS

1220
185

1200
240

1210
295

1210
350

1210
410

ON

ON

OFF

CFM
WATTS

1390
245

1390
320

1410
391

1410
470

1400
510

OFF

ON

OFF

ON

CFM
WATTS

1214
185

1210
240

1215
295

1210
350

1210
415

NORMAL
(400 CFM/TON)

OFF

ON

OFF

OFF

CFM
WATTS

1430
310

1460
355

1470
430

1460
500

1440
555

HIGH
(450 CFM/TON)

OFF

ON

ON

OFF

CFM
WATTS

1640
370

1665
460

1650
540

1640
615

1610
660

LOW
(350 CFM/TON)

ON

OFF

OFF

ON

CFM
WATTS

1405
270

1430
310

1440
375

1440
480

1420
550

NORMAL
(400 CFM/TON)

ON

OFF

OFF

OFF

CFM
WATTS

1670
395

1675
490

1670
550

1655
630

1630
700

HIGH
(450 CFM/TON)

ON

OFF

ON

OFF

CFM
WATTS

1870
540

1880
635

1880
730

1845
800

1670
640

LOW
(350 CFM/TON)

OFF

OFF

OFF

ON

CFM
WATTS

1775
480

1800
580

1820
680

1800
750

1680
740

NORMAL **
(400 CFM/TON)

OFF

OFF

OFF

OFF

CFM
WATTS

2065
755

2020
840

1945
900

1805
880

1623
800

HIGH
(450 CFM/TON)

OFF

OFF

ON

OFF

CFM
WATTS

2310
1000

2100
1000

2100
950

1965
890

1800
825

LOW
(350 CFM/TON)

ON

ON

OFF

NORMAL
(400 CFM/TON)

ON

ON

HIGH
(450 CFM/TON)

ON

LOW
(350 CFM/TON)

SW 4

NOTES:
1. * First letter may be "A" or "T"
2. ** Factory setting
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting

14	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

*UD2C100B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW 7

SW 8

LOW

ON

ON

MEDIUM **

ON

HIGH

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

CFM
TEMP. RISE
WATTS

953
50
93

944
50
146

936
51
193

908
52
243

887
54
292

OFF

CFM
TEMP. RISE
WATTS

1142
42
135

1141
42
200

1135
42
255

1112
43
322

1098
43
377

OFF

OFF

CFM
TEMP. RISE
WATTS

1258
38
169

1260
38
240

1256
38
302

1236
38
378

1227
39
437

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1312
52
188

1317
52
261

1314
52
326

1294
53
406

1287
53
468

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1577
44
301

1592
43
387

1592
43
468

1597
43
563

1582
43
644

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1739
39
392

1761
39
486

1762
39
575

1753
39
675

1762
39
774

*UD2C100B9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

3.0

3.5

4.0

5.0 **

AIRFLOW
SETTING

DIP SWITCH SETTING
SW 1

SW 2

SW 3

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

ON

CFM
WATTS

1056
114

1050
173

1044
225

1019
284

1002
336

OFF

OFF

CFM
WATTS

1199
151

1199
219

1194
277

1172
349

1161
405

ON

ON

OFF

CFM
WATTS

1342
198

1348
273

1345
340

1326
422

1320
486

OFF

ON

OFF

ON

CFM
WATTS

1223
158

1224
227

1219
287

1198
361

1187
418

NORMAL
(400 CFM/TON)

OFF

ON

OFF

OFF

CFM
WATTS

1389
217

1397
294

1395
363

1377
449

1373
515

HIGH
(450 CFM/TON)

OFF

ON

ON

OFF

CFM
WATTS

1556
291

1570
376

1570
455

1556
549

1559
629

LOW
(350 CFM/TON)

ON

OFF

OFF

ON

CFM
WATTS

1389
217

1397
294

1395
363

1377
449

1373
515

NORMAL
(400 CFM/TON)

ON

OFF

OFF

OFF

CFM
WATTS

1580
303

1595
389

1595
469

1582
565

1585
647

HIGH
(450 CFM/TON)

ON

OFF

ON

OFF

CFM
WATTS

1770
411

1793
507

1795
598

1787
698

1797
801

LOW
(350 CFM/TON)

OFF

OFF

OFF

ON

CFM
WATTS

1723
382

1744
475

1754
564

1735
663

1744
760

NORMAL **
(400 CFM/TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1961
546

1991
652

1996
751

1991
850

2010
981

HIGH
(450 CFM/TON)

OFF

OFF

ON

OFF

CFM
WATTS

2199
754

2217
875

2217
983

2197
1067

1987
943

LOW
(350 CFM/TON)

ON

ON

OFF

NORMAL
(400 CFM/TON)

ON

ON

HIGH
(450 CFM/TON)

ON

LOW
(350 CFM/TON)

SW 4

NOTES:
1. * First letter may be "A" or "T"
2. ** Factory setting
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

15

*UD2D120A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW7

SW8

LOW

ON

ON

MEDIUM **

ON

HIGH

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

CFM
TEMP. RISE
WATTS

1007
57
114

1062
54
177

1084
53
285

1063
54
303

1063
54
350

OFF

CFM
TEMP. RISE
WATTS

1154
50
167

1211
48
230

1211
48
277

1221
47
344

1212
48
417

OFF

OFF

CFM
TEMP. RISE
WATTS

1288
45
208

1319
44
273

1310
44
330

1349
43
410

1358
43
460

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1387
64
250

1421
63
320

1455
61
400

1488
60
460

1495
59
540

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1589
56
350

1637
54
440

1666
53
535

1678
53
600

1541
58
575

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1771
50
475

1788
50
560

1804
49
650

1751
51
675

1554
57
590

*UD2D120A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

3.5

4

5 **

AIRFLOW
SETTING
(See Notes)

DIP SWITCH SETTING
SW1

SW2

SW3

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

ON

CFM
WATTS

1195
150

1243
225

1235
275

1251
325

1251
410

OFF

OFF

CFM
WATTS

1353
210

1403
290

1417
370

1437
425

1458
485

ON

ON

OFF

CFM
WATTS

1554
315

1572
410

1615
480

1634
570

1567
575

ON

OFF

OFF

ON

CFM
WATTS

1356
200

1391
280

1399
370

1433
420

1454
510

NORMAL
(400 CFM/ TON)

ON

OFF

OFF

OFF

CFM
WATTS

1565
320

1584
410

1633
475

1639
560

1554
575

HIGH
(450 CFM/ TON)

ON

OFF

ON

OFF

CFM
WATTS

1766
450

1799
550

1810
650

1784
685

1590
600

LOW
(350 CFM/ TON)

OFF

OFF

OFF

ON

CFM
WATTS

1708
420

1758
530

1759
585

1775
675

1575
585

NORMAL **
(400 CFM/ TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1994
665

2018
775

1971
785

1814
725

1618
625

HIGH
(450 CFM/ TON)

OFF

OFF

ON

OFF

CFM
WATTS

2247
975

2152
925

2019
860

1861
765

1693
680

LOW
(350 CFM/ TON)

OFF

ON

OFF

NORMAL
(400 CFM/ TON)

OFF

ON

HIGH
(450 CFM/ TON)

OFF

LOW
(350 CFM/ TON)

SW4

NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".
1. *FIRST LETTER MAY BE "A" OR "T"
2. **FACTORY SETTING.
3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING:
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.

16	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

*UD2D120B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
S4-3

S4-4

LOW

ON

ON

MEDIUM **

ON

HIGH

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

CFM
TEMP. RISE
WATTS

1050
45
99

1044
46
146

1035
46
208

1005
47
252

980
48
310

OFF

CFM
TEMP. RISE
WATTS

1214
39
129

1216
39
188

1217
39
262

1192
40
252

1169
41
310

OFF

OFF

CFM
TEMP. RISE
WATTS

1288
37
147

1293
37
212

1298
37
293

1275
37
309

1254
38
373

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1429
48
191

1440
48
267

1453
47
363

1435
48
340

1416
48
406

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1672
41
310

1695
40
402

1722
40
528

1711
40
409

1697
40
480

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1782
39
385

1809
38
480

1890
36
623

1835
37
565

1871
37
644

*UD2D120B9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

3.5

4.0

5.0 **

AIRFLOW
SETTING
(See Notes)

DIP SWITCH SETTING

EXTERNAL STATIC PRESSURE

S3-1

S3-2

S3-3

S3-4

0.1

0.3

0.5

0.7

0.9

LOW
(350 CFM/ TON)

OFF

ON

OFF

ON

CFM
WATTS

1208
128

1209
186

1210
260

1185
306

1162
370

NORMAL
(400 CFM/ TON)

OFF

ON

OFF

OFF

CFM
WATTS

1343
162

1350
232

1358
318

1337
365

1317
433

HIGH
(450 CFM/ TON)

OFF

ON

ON

OFF

CFM
WATTS

1477
210

1491
290

1507
391

1490
436

1472
508

LOW
(350 CFM/ TON)

ON

OFF

OFF

ON

CFM
WATTS

1343
162

1350
232

1358
318

1337
365

1317
433

NORMAL
(400 CFM/ TON)

ON

OFF

OFF

OFF

CFM
WATTS

1496
218

1511
300

1528
403

1511
447

1494
520

HIGH
(450 CFM/ TON)

ON

OFF

ON

OFF

CFM
WATTS

1650
296

1671
387

1698
511

1686
548

1671
626

LOW
(350 CFM/ TON)

OFF

OFF

OFF

ON

CFM
WATTS

1612
274

1631
363

1655
482

1642
521

1627
598

NORMAL **
(400 CFM/ TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1858
403

1902
533

1907
624

1906
714

1871
755

HIGH
(450 CFM/ TON)

OFF

OFF

ON

OFF

CFM
WATTS

1871
585

2126
711

2110
797

2098
888

2001
953

NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".
1. *FIRST LETTER MAY BE "A" OR "T"
2. **FACTORY SETTING.
3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING:
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

17

*UD2D140A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING

HEATING
1ST
STAGE

HEATING
2ND
STAGE

DIP SWITCH SETTING
SW 7

EXTERNAL STATIC PRESSURE

SW 8

0.1

0.3

0.5

0.7

0.9

1090
62
130

1100
61
175

1070
63
215

1080
62
255

1060
63
290

LOW

ON

ON

CFM
TEMP. RISE
WATTS

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1230
55
180

1265
53
235

1280
53
315

1300
52
380

1300
52
455

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

1380
49
235

1405
48
290

1425
47
375

1430
47
415

1450
47
520

LOW

ON

ON

CFM
TEMP. RISE
WATTS

1545
67
320

1550
67
385

1560
67
475

1560
67
540

1575
66
605

MEDIUM **

ON

OFF

CFM
TEMP. RISE
WATTS

1760
59
435

1790
58
545

1810
58
620

1800
58
695

1725
60
725

HIGH

OFF

OFF

CFM
TEMP. RISE
WATTS

2000
52
615

2010
52
715

2000
52
790

1950
54
820

1800
58
775

*UD2D140A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)

3.5

4.0

5.0 **

AIRFLOW
SETTING

DIP SWITCH SETTING
SW 1

SW 2

SW 3

EXTERNAL STATIC PRESSURE
0.1

0.3

0.5

0.7

0.9

ON

CFM
WATTS

1175
165

1165
200

1180
265

1170
320

1150
400

OFF

OFF

CFM
WATTS

1345
225

1370
285

1400
360

1405
440

1380
490

ON

ON

OFF

CFM
WATTS

1525
295

1565
390

1585
470

1575
515

1530
585

ON

OFF

OFF

ON

CFM
WATTS

1320
220

1330
275

1335
355

1300
435

1240
490

NORMAL
(400 CFM/TON)

ON

OFF

OFF

OFF

CFM
WATTS

1550
310

1580
400

1590
475

1555
540

1460
610

HIGH
(450 CFM/TON)

ON

OFF

ON

OFF

CFM
WATTS

1735
430

1735
510

1710
600

1670
675

1590
710

LOW
(350 CFM/TON)

OFF

OFF

OFF

ON

CFM
WATTS

1700
415

1725
470

1730
560

1725
640

1690
700

NORMAL **
(400 CFM/TON)

OFF

OFF

OFF

OFF

CFM
WATTS

1980
616

1980
710

1950
770

1885
780

1735
735

HIGH
(450 CFM/TON)

OFF

OFF

ON

OFF

CFM
WATTS

2190
835

2150
870

2075
890

1905
800

1735
735

LOW
(350 CFM/TON)

OFF

ON

OFF

NORMAL
(400 CFM/TON)

OFF

ON

HIGH
(450 CFM/TON)

OFF

LOW
(350 CFM/TON)

SW 4

NOTES:
1. * First Letter may be "A" or "T"
2. ** Factory setting
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting

18	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

PRODUCT DATA
WIRING DIAGRAM

From Dwg. D344249P02

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

19

PRODUCT DATA

SCHEMATIC DIAGRAMS

From Dwg. D344249P02

20	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

PRODUCT DATA
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY

TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES

M SEE
HUM SEE
NOTE 5

EAC SEE

NOE
TEE
5
S

From Dwg. 21B341127 Rev. 0

FIELD WIRING DIAGRAM FOR TWO STAGE HEATING

TO 115 V 1 PH.,

60 HZ., POWER
M
SYEE
EPERE
SUPPL
LOCAL CODES
TE 5
HUM SEE
NOTE 5

CEASC SEE
EE
NOTE 5
TE 5

From Dwg. 21B341126 Rev. 0

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

21

PRODUCT DATA
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING WITH SINGLE STAGE COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)

From Dwg. 21B341125 Rev. 1

FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH SINGLE STAGE COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)

From Dwg. 21B341124 Rev. 1

22	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

22-1650-13

PRODUCT DATA
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH TWO STAGE COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)

TO 115 V 1 PH.,

WER
S60
EHZ.,
EE
E YPOPER
SUPPL
LOCAL CODES
5

HUM SEE
W
ER
R6
6
NOTE 5

DEAEC S
SEEL
NOTE 5

From Dwg. 21B341128 Rev. 0

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

23

24	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

13-1/16"

15-5/16"

24-1/2"

9-5/8"

B

21"

17-1/2"

A

* - First Letter May Be "A" or "T"
** - Suffix Letters May Be "K" (0 Through 9)

*UD2C080A9V4V**
*UD2C100A9V5V**
*UD2C080B9V4V**
*UD2C100B9V5V**
*UD2D120A9V5V**
*UD2D140A9V5V**
*UD2D120B9V5V**

*UD2B060A9V3V**
*UD2B080A9V3V**
*UD2B100A9V3V**

MODEL

(ALL DIMENSIONS ARE IN INCHES)

C

23-1/4"

19-3/4"

16-1/4"

TUD-9V OUTLINE DRAWING

23"

19-1/2"

16"

D

From Dwg. C341699

PRODUCT DATA

22-1650-13

22-1650-13	

DATA SUBJECT TO CHANGE WITHOUT NOTICE	

25

PRODUCT DATA

Since the manufacturer has a policy of continuous product
and product data improvement, it reserves the right to change
the design and specifications without notice.

Technical Literature - Printed in U.S.A.

Trane

6200 Troup Highway
Tyler, TX 75707



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 26
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:cda6a338-2292-40fa-8ffa-61f0cd6915b1
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Acces flag                      : F
Alt order nbr                   : 
Alt order nbr type              : 
Bw color                        : B
Date published                  : 11/01/2011
Dept id                         : 54
Topic focused id                : TRANE|EN
Price                           : 0
Cur flag                        : T
Lit class id                    : PL
Lit length                      : 26
Lit order nbr                   : 22-1650-13
Lit type id                     : PRD
Media id                        : ELO
Model                           : TUD
Prod class                      : UN
Prod family id                  : 105
Prod                            : FURN
Restrct flag                    : F
Source date                     : nulldate
Source filename                 : 
Stocking loc id                 : None
Supceded by                     : 
Supceded by date                : 02/01/2008
Unit flag                       : T
Branding                        : Trane
Lol language                    : EN
Object id                       : 090102b182a98ea1
Object name                     : 22-1650-13_11012011
Chronicle id                    : 090102b182242a9b
Filename                        : 82a98ea1.pdf
Abstract                        :  Contains  Information on the XV 80 furnace. TUD-9V Models  Features and benefits- standard and optional equipment, general data - product specifications, performance data, schematic diagrams, field wiring diagrams, outline drawing
Hist model                      : TUD2B060A9V3VB|TUD2C080A9V4VB|TUD2B100A9V3VB|TUD2C100B9V5VB|TUD2D120B9V5VB|TUD2B080A9V3VB|TUD2C080B9V4VB|TUD2C100A9V5VB|TUD2D120A9V5VB|TUD2D140A9V5VB
Topic related id                : TRN-FLD|SYS-DSN|STARTUP|SERVICER|SERV|RRR|OWN/DEV|OPER|INST|DSGN
Create Date                     : 2011:11:18 11:17:46-06:00
Modify Date                     : 2011:11:29 16:41:10-06:00
Metadata Date                   : 2011:11:29 16:41:10-06:00
Creator Tool                    : Adobe InDesign CS5 (7.0.4)
Instance ID                     : uuid:a8348636-194f-4819-aad2-73ffc44c48ef
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:fbadfd85-a3bf-11df-acf7-893be6199ab3
Original Document ID            : adobe:docid:indd:fbadfd85-a3bf-11df-acf7-893be6199ab3
Derived From Instance ID        : fbadfd84-a3bf-11df-acf7-893be6199ab3
Derived From Document ID        : adobe:docid:indd:479a3c6a-a334-11df-b0b9-8e277e6b536f
History Action                  : saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:F5508B4EFB11E111B83387B5860E372F, xmp.iid:F6508B4EFB11E111B83387B5860E372F, xmp.iid:D9AFD5E20412E111B83387B5860E372F, xmp.iid:DAAFD5E20412E111B83387B5860E372F, xmp.iid:0FB657FA0412E111B83387B5860E372F, xmp.iid:FD8D41610512E111B83387B5860E372F, xmp.iid:EE36DC330912E111B83387B5860E372F
History When                    : 2011:11:18 09:38:05-06:00, 2011:11:18 09:38:05-06:00, 2011:11:18 10:46:39-06:00, 2011:11:18 10:46:39-06:00, 2011:11:18 10:49:08-06:00, 2011:11:18 10:50:11-06:00, 2011:11:18 11:17:33-06:00
History Software Agent          : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0
History Changed                 : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata
N Pages                         : 26
Doc Change Count                : 14
Format                          : application/pdf
Title                           : 22-1650-13 11/01/2011 Trane Product Data Upflow-Horizontal Two-Stage Variable Speed Gas-Fired Furnace XV 80 TUD-9V Models Two-Stage Fan Assisted Combustion System
Tagged PDF                      : Yes
Creator                         : Adobe InDesign CS5 (7.0.4)
Acces Flag                      : F
Alt Order Nbr                   : 
Alt Order Nbr Type              : 
Bw Color                        : B
Hist Model                      : TUD2B060A9V3VB|TUD2C080A9V4VB|TUD2B100A9V3VB|TUD2C100B9V5VB|TUD2D120B9V5VB|TUD2B080A9V3VB|TUD2C080B9V4VB|TUD2C100A9V5VB|TUD2D120A9V5VB|TUD2D140A9V5VB
Date Published                  : 11/01/2011
Dept Id                         : 54
Topic Focused Id                : TRANE|EN
Cur Flag                        : T
Lit Class Id                    : PL
Lit Length                      : 26
Lit Order Nbr                   : 22-1650-13
Lit Type Id                     : PRD
Media Id                        : ELO
Prod Class                      : UN
Prod Family Id                  : 105
Topic Related Id                : TRN-FLD|SYS-DSN|STARTUP|SERVICER|SERV|RRR|OWN/DEV|OPER|INST|DSGN
Restrct Flag                    : F
Source Date                     : nulldate
Source Filename                 : 
Stocking Loc Id                 : None
Supceded By                     : 
Supceded By Date                : 02/01/2008
Unit Flag                       : T
Lol Language                    : EN
Object Id                       : 090102b182a98ea1
Object Name                     : 22-1650-13_11012011
Chronicle Id                    : 090102b182242a9b
EXIF Metadata provided by EXIF.tools

Navigation menu