Trane Tud2B080A9V3Vb Users Manual 22 1650 13 11/01/2011 Product Data Upflow Horizontal Two Stage Variable Speed Gas Fired Furnace XV 80 TUD 9V S St
Trane Furnace TUD2D140A9V5VB XV80-Performance-Data
TUD2D140A9V5VB to the manual 57e68683-78fa-4aaa-83b2-dda83174b585
2015-01-21
: Trane Trane-Tud2B080A9V3Vb-Users-Manual-236169 trane-tud2b080a9v3vb-users-manual-236169 trane pdf
Open the PDF directly: View PDF
.
Page Count: 26
| Download | |
| Open PDF In Browser | View PDF |
UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B100A9V3VB, TUD2C100A9V5VB TUD2C100B9V5VB, TUD2D120A9V5VB TUD2D120B9V5VB, TUD2D140A9V5VB Two-Stage FanAssisted CombustionSystem PUB. NO. 22-1650-13 © 2011 Trane General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standart rating conditions using American National Standards Instirute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heaating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier. © 2011 Trane 2 AIR DELIVERY The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. Some models are available with high efficiency blowers. STYLING Heavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION The XV80 High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. 22-1650-13 Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data 22-1650-13 4 5 6 TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB TUD2C080B9V4VB TUD2B100A9V3VB TUD2C100A9V5VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D120B9V5VB TUD2D140A9V5VB Performance Data 9 Electric Data 19 Field Wiring Diagrams 19 Dimensions 24 3 Features and Benefits XV80 STANDARD EQUIPMENT • Upflow/Horizontal and • Power supply 115/1/60 • 2-stage gas valve • 2-speed venter • Variable speed blower motor • Silicon Nitride hot surface igniter with adaptive heat up • Integrated solid state control • Attractive color accents • Heavy gauge aluminized steel heat exchanger • Multi-port In-shot burners • Complete front service access • Alternate bottom/left/right return air • Slide out blower assembly • Hinged blower door • Perfect fit door catches 4 • Insulated blower door • Gasketed blower door • Internal filter rack • Standard filter sizes • Two-tone color • Direct drive, variable speed motor • Integrated solid state control with self-diagnostics • Common vent capability • Cleanable framed filters • Optional L.P. conversion kit • Left/right gas connection • Accessory hook-up capability • Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit • Enhanced cooling control 22-1650-13 Features and Benefits XV80 OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling......................................................................................... TAYSTAT241 [ Thermostat, Mechanical Heating Only With Fan Switch.............................................................................................. BAYSTAT303 [ Thermostat, Mechanical Heating Only........................................................................................................................ BAYSTAT388 [ Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ..................................................................................AY28X092 [ Thermostat, Electronic Non-programmable 1-Stage Heating/1-Stage Cooling........................................................... BAYSTAT370 [ Thermostat, Electronic Programmable (5-2) 1-Stage Heating/1-Stage Cooling.......................................................... BAYSTAT340 [ Thermostat, Heating/Cooling Single Stage (Mounts Vertically)................................................................................... BAYSTAT305 [ Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling................................................................ TAYSTAT302C [ Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling................................................................ TAYSTAT300C [ Propane Conversion Kit............................................................................................................................................ BAYLPKT210A [ Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace)......................................................... TFM175A9FR0 [ Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace)............................................................... TFM210A9FR0 [ Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace)......................................................... TFM245A9FR0 [ Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace)..................................................TFP175A9FR0 [ Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace).........................................................TFP210A9FR0 [ Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace)..................................................TFP245A9FR0 [ Coil Enclosure (17-1/2" Wide Cabinets)............................................................................................................. BAYCLE17A1722A [ Coil Enclosure (21" Wide Cabinets)................................................................................................................... BAYCLE21A2130A [ Coil Enclosure (24-1/2" Wide Cabinets)............................................................................................................. BAYCLE24A2430A [ Side Filter Rack........................................................................................................................................................... BAYFLTR200 [ High Altitude Switch..................................................................................................................................................... BAYHALT249 [ Masonry Chimney Vent Kit (Upflow models only).....................................................................................................BAYVENT800B [ Filter Rack Kit 1 ..................................................................................................................................................... BAYRACK960A [ 1 Available for models with 1800 CFM or greater which require an additional side return. 22-1650-13 5 ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] GENERAL DATA TUD-R9V PRODUCT SPECIFICATIONS1 MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L. P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (In.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs.) TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal 39,000 31,200 60,000 48,000 30 - 60 52,000 41,600 80,000 64,000 30 - 60 52,000 41,600 80,000 64,000 30 - 60 Direct 10 x 7 1 Variable See Airflow Table 1/2 Variable 115/1/60 Direct 10 x 7 1 Variable See Airflow Table 1/2 Variable 115/1/60 Direct 10 x 10 1 Variable See Airflow Table 3/4 Variable 115/1/60 Centrifugal Direct - 2 1/50 - 3000 115/1/60 0.7 Centrifugal Direct - 2 1/50 - 3000 115/1/60 0.7 Centrifugal Direct - 2 1/50 - 3000 115/1/60 0.7 Yes High Velocity 1 - 17x25 - 1in. Yes High Velocity 1 - 17x25 - 1in. Yes High Velocity 1 - 20x25 - 1in. 4 Round 4 Round 4 Round Alum. Steel - Type 1 Alum. Steel - Type 1 Alum. Steel - Type 1 20 20 20 3 — 45 3 — 56 4 — 45 4 — 56 4 — 45 4 — 56 Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Multi-port In-shot 3 Multi-port In-shot 4 Multi-port In-shot 4 115/1/60 10.5 15 115/1/60 10.5 15 115/1/60 12.9 20 1/2 1/2 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 HxWxD 41-3/4 x 23 x 30-1/2 136 / 126 142 / 132 166 / 155 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 TUD-R9V PRODUCT SPECIFICATIONS1 MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L. P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (In.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs.) TUD2C080B9V4VB 5 TUD2B100A9V3VB TUD2C100A9V5VB Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal 52,000 41,600 80,000 64,000 30 - 60 65,000 52,000 100,000 80,000 40 - 70 65,000 52,000 100,000 79,000 35 - 65 Direct 10 x 10 1 Variable See Airflow Table 3/4 Variable 115/1/60 Direct 10 x 7 1 Variable See Airflow Table 1/2 Variable 115/1/60 Direct 10 x 10 1 Variable See Airflow Table 1 Variable 115/1/60 Centrifugal Direct - 2 1/50 - 3000 115/1/60 0.7 Centrifugal Direct - 2 1/50 - 3000 115/1/60 0.87 Centrifugal Direct - 2 1/50 - 3000 115/1/60 0.87 Yes High Velocity 1 - 20x25 - 1in. Yes High Velocity 1 - 17x25 - 1in. Yes High Velocity 1 - 20x25 - 1in. 4 Round 4 Round 4 Round Alum. Steel - Type 1 Alum. Steel - Type 1 Alum. Steel - Type 1 20 20 20 4 — 45 4 — 56 5 — 45 5 — 56 5 — 45 5 — 56 Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Multi-port In-shot 4 Multi-port In-shot 5 Multi-port In-shot 5 115/1/60 12.9 20 115/1/60 10.8 15 115/1/60 14.9 20 1/2 1/2 1/2 HxWxD 41-3/4 x 23 x 30-1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 HxWxD 41-3/4 x 23 x 30-1/2 166 / 155 142 / 132 166 / 155 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Model uses high efficiency blower. 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 7 TUD-R9V PRODUCT SPECIFICATIONS1 MODEL TUD2C100B9V5VB 5 TUD2D120A9V5VB TUD2D120B9V5VB 5 TUD2D140A9V5VB Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal 65,000 52,000 100,000 79,000 35 - 65 78,000 62,400 120,000 97,000 35 - 65 78,000 62,400 120,000 97,000 35 - 65 91,000 72,800 140,000 111,000 40 - 70 Direct 10 x 10 1 Variable See Airflow Table 1 Variable 115/1/60 Direct 10 x 10 1 Variable See Airflow Table 1 Variable 115/1/60 Direct 10 x 10 1 Variable See Airflow Table 1 Variable 115/1/60 Direct 10 x 10 1 Variable See Airflow Table 1 Variable 115/1/60 Centrifugal Direct - 2 1/50 - 3000 115/1/60 0.87 Centrifugal Direct - 2 1/50 - 3000 115/1/60 1.14 Centrifugal Direct - 2 1/50 - 3000 115/1/60 1.14 Centrifugal Direct - 2 1/50 - 3000 115/1/60 1.16 Yes High Velocity 1 - 20x25 - 1in. Yes High Velocity 1 - 24x25 - 1in. Yes High Velocity 1 - 24x25 - 1in. Yes High Velocity 1 - 24x25 - 1in. 4 Round 4 Round 4 Round 4 Round Alum. Steel - Type 1 Alum. Steel - Type 1 Alum. Steel - Type 1 Alum. Steel - Type 1 20 20 20 20 5 — 45 5 — 56 6 — 45 6 — 56 6 — 45 6 — 56 7 — 45 7 — 56 Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Multi-port In-shot 5 Multi-port In-shot 6 Multi-port In-shot 6 Multi-port In-shot 7 115/1/60 14.9 20 115/1/60 15.3 20 115/1/60 15.3 20 115/1/60 15.3 20 TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L. P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (In.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs.) 1/2 1/2 1/2 1/2 HxWxD 41-3/4 x 23 x 30-1/2 HxWxD 41-3/4 x 26-1/2 x 30-1/2 HxWxD 41-3/4 x 26-1/2 x 30-1/2 HxWxD 41-3/4 x 26-1/2 x 30-1/2 166 / 155 193 / 181 193 / 181 197 / 185 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Model uses high efficiency blower. 8 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 *UD2B060A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW7 EXTERNAL STATIC PRESSURE SW8 0.1 0.3 0.5 0.7 0.9 589 49 65 604 48 95 619 47 125 604 48 160 607 48 200 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 663 44 75 694 42 120 684 42 145 681 42 185 686 42 220 HIGH OFF OFF CFM TEMP. RISE WATTS 775 37 105 781 37 145 776 37 180 805 36 230 811 36 270 LOW ON ON CFM TEMP. RISE WATTS 813 55 110 818 54 150 818 54 185 837 53 240 842 53 280 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 907 49 140 919 48 200 942 47 240 958 46 300 959 46 330 HIGH OFF OFF CFM TEMP. RISE WATTS 1038 43 190 1066 42 260 1086 41 325 1089 41 365 1079 41 415 *UD2B060A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 1.5 2 2.5 3 ** AIRFLOW SETTING DIP SWITCH SETTING SW1 SW2 SW3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 499 50 537 80 520 110 520 145 500 175 OFF OFF CFM WATTS 605 60 610 80 610 120 597 155 593 180 ON ON OFF CFM WATTS 649 75 681 110 665 145 665 180 672 220 OFF ON OFF ON CFM WATTS 680 80 722 125 680 150 696 190 696 225 NORMAL (400 CFM/ TON) OFF ON OFF OFF CFM WATTS 798 105 804 145 809 170 823 235 818 280 HIGH (450 CFM/ TON) OFF ON ON OFF CFM WATTS 884 145 896 180 924 240 931 280 931 330 LOW (350 CFM/ TON) ON OFF OFF ON CFM WATTS 858 125 863 175 882 220 894 275 895 320 NORMAL (400 CFM/ TON) ON OFF OFF OFF CFM WATTS 984 170 1017 225 1038 295 1017 330 1017 375 HIGH (450 CFM/ TON) ON OFF ON OFF CFM WATTS 1125 245 1138 315 1150 370 1161 435 1161 475 LOW (350 CFM/ TON) OFF OFF OFF ON CFM WATTS 1035 205 1056 265 1076 330 1076 370 1076 430 NORMAL ** (400 CFM/ TON) OFF OFF OFF OFF CFM WATTS 1208 300 1247 360 1268 440 1278 485 1200 490 HIGH (450 CFM/ TON) OFF OFF ON OFF CFM WATTS 1380 440 1410 500 1402 550 1350 550 1235 525 LOW (350 CFM/ TON) ON ON OFF NORMAL (400 CFM/ TON) ON ON HIGH (450 CFM/ TON) ON LOW (350 CFM/ TON) SW4 NOTES: 1. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY SETTING. 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 9 *UD2B080A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 0.1 0.3 0.5 0.7 0.9 800 48 100 790 49 135 765 50 155 750 52 200 730 53 230 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 910 43 130 890 44 170 875 44 210 860 45 240 820 47 280 HIGH OFF OFF CFM TEMP. RISE WATTS 1060 37 188 1020 38 220 1010 39 265 1010 39 310 1000 39 350 LOW ON ON CFM TEMP. RISE WATTS 1110 54 210 1090 55 260 1090 55 310 1080 55 350 1065 56 400 ON OFF CFM TEMP. RISE WATTS 1245 48 300 1240 48 355 1240 48 410 1230 48 460 1215 49 500 OFF OFF CFM TEMP. RISE WATTS 1415 42 410 1400 42 470 1400 42 530 1375 43 580 1320 45 590 MEDIUM ** HIGH *UD2B080A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 3.5 ** AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 880 120 875 155 860 190 845 225 840 245 OFF OFF CFM WATTS 1020 170 1000 205 990 240 980 280 960 320 ON ON OFF CFM WATTS 1110 210 110 260 1110 320 1100 350 1100 385 ON OFF OFF ON CFM WATTS 1040 190 1010 220 1000 260 1000 310 990 340 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1200 250 1200 320 1190 370 1190 415 1175 450 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1340 355 1340 425 1330 475 1320 530 1300 570 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1215 265 1210 330 1210 375 1200 430 1185 465 NORMAL ** (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1430 415 1415 457 1410 520 1385 575 1330 580 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1430 415 1415 475 1410 520 1385 575 1330 580 LOW (350 CFM/TON) OFF ON OFF NORMAL (400 CFM/TON) OFF ON HIGH (450 CFM/TON) OFF LOW (350 CFM/TON) SW 4 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 10 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 *UD2C080A9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 0.1 0.3 0.5 0.7 0.9 782 49 75 762 51 110 751 51 145 748 51 185 737 52 225 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 870 44 90 865 45 125 861 45 175 848 45 215 831 46 255 HIGH OFF OFF CFM TEMP. RISE WATTS 962 40 110 974 40 155 963 40 200 938 41 245 914 42 290 LOW ON ON CFM TEMP. RISE WATTS 1091 54 145 1092 54 190 1087 55 245 1092 54 305 1077 55 355 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1211 49 190 1243 48 255 1243 48 310 1244 48 370 1235 48 430 HIGH OFF OFF CFM TEMP. RISE WATTS 1371 43 255 1388 43 325 1392 43 395 1385 43 455 1377 43 515 *UD2C080A9V4VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 3.5 4 ** AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 863 90 865 130 858 175 843 220 831 255 OFF OFF CFM WATTS 995 115 1005 170 989 210 973 260 956 305 ON ON OFF CFM WATTS 1101 150 1112 200 1111 255 1107 305 1101 360 OFF ON OFF ON CFM WATTS 1031 125 1031 175 1026 215 1013 270 1003 320 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1163 170 1178 230 1188 285 1183 345 1178 405 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1319 240 1337 305 1344 365 1340 420 1336 485 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1182 200 1206 240 1211 295 1211 350 1211 420 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1380 255 1401 325 1402 390 1402 460 1399 515 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1553 350 1566 425 1557 500 1558 560 1559 645 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1386 255 1401 330 1408 395 1402 460 1390 520 NORMAL ** (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1590 360 1593 440 1591 515 1588 575 1576 650 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1791 360 1808 615 1810 615 1808 775 1726 800 LOW (350 CFM/TON) ON ON OFF NORMAL (400 CFM/TON) ON ON HIGH (450 CFM/TON) ON LOW (350 CFM/TON) SW 4 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 11 *UD2C080B9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 0.1 0.3 0.5 0.7 0.9 974 49 133 968 49 285 949 50 202 925 51 254 906 52 304 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1102 43 93 1112 43 144 1103 43 201 1083 44 255 1066 45 305 HIGH OFF OFF CFM TEMP. RISE WATTS 1194 40 119 1217 39 180 1215 39 243 1200 40 304 1182 40 362 LOW ON ON CFM TEMP. RISE WATTS 1189 58 142 1210 57 209 1209 57 276 1193 58 341 1175 58 404 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1346 51 141 1388 49 207 1398 49 274 1390 49 339 1372 50 401 HIGH OFF OFF CFM TEMP. RISE WATTS 1460 47 186 1516 45 263 1536 45 335 1533 45 407 1515 45 477 *UD2C080B9V4VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 3.5 4 ** AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW (350 CFM/TON) ON ON OFF ON CFM WATTS 842 71 819 114 789 163 756 207 740 249 NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS 956 90 948 140 928 196 901 248 884 298 HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 1071 113 1078 171 1067 233 1045 292 1028 348 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 1002 99 1000 152 983 210 958 265 942 318 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1140 128 1155 191 1150 256 1132 319 1114 379 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1278 165 1311 238 1316 308 1305 377 1287 444 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1163 134 1181 199 1177 265 1161 328 1143 389 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1324 179 1363 255 1372 326 1363 397 1345 466 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1485 234 1544 319 1566 396 1565 472 1546 550 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1324 179 1363 255 1372 326 1363 397 1345 466 NORMAL ** (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1508 243 1570 329 1594 407 1593 483 1575 562 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1691 322 1777 416 1816 499 1824 579 1805 669 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 12 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 *UD2B100A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 751 64 86 796 61 132 817 59 175 832 58 218 838 57 263 OFF CFM TEMP. RISE WATTS 862 56 121 921 52 185 953 51 233 967 50 285 954 50 322 OFF OFF CFM TEMP. RISE WATTS 959 50 148 1002 48 210 1036 46 280 1036 46 325 1003 48 355 LOW ON ON CFM TEMP. RISE WATTS 1099 67 227 1124 66 287 1149 64 355 1157 64 415 1055 70 395 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1286 58 365 1321 56 450 1313 56 455 1215 61 475 1119 66 450 HIGH OFF OFF CFM TEMP. RISE WATTS 1399 53 465 1419 52 570 1347 55 545 1265 59 520 1163 64 485 *UD2B100A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 1.5 2.0 2.5 3.0** AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 516 50 536 75 551 105 547 135 530 165 OFF OFF CFM WATTS 583 59 615 92 633 127 621 157 618 18 ON ON OFF CFM WATTS 681 70 697 110 701 140 709 180 712 215 OFF ON OFF ON CFM WATTS 680 75 726 120 735 150 741 190 745 230 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 769 103 819 145 843 190 858 235 865 286 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 882 130 938 190 961 245 975 300 970 345 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 831 180 903 180 928 230 935 275 935 320 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 979 167 1036 240 1053 295 1053 345 1015 368 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1121 245 1147 310 1176 383 1167 442 1055 396 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1061 210 1081 265 1095 320 1101 382 1032 380 NORMAL ** (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1185 278 1223 364 1251 435 1205 455 1101 426 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1351 425 1372 503 1343 535 1248 505 1168 480 LOW (350 CFM/TON) ON ON OFF NORMAL (400 CFM/TON) ON ON HIGH (450 CFM/TON) ON LOW (350 CFM/TON) SW 4 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 13 *UD2C100A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 900 53 100 890 54 130 870 55 175 850 57 220 835 58 270 OFF CFM TEMP. RISE WATTS 1125 43 150 1090 44 200 1060 46 235 1070 45 300 1070 45 340 OFF OFF CFM TEMP. RISE WATTS 1300 37 220 1300 37 290 1320 36 365 1350 36 430 1340 36 490 LOW ON ON CFM TEMP. RISE WATTS 1270 59 200 1290 58 260 1290 58 335 1290 58 400 1280 58 460 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1575 47 355 1600 46 445 1610 46 520 1600 46 575 1580 47 650 HIGH OFF OFF CFM TEMP. RISE WATTS 1870 40 560 1890 39 665 1860 40 710 1870 40 830 1730 43 760 *UD2C100A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.0 3.5 4.0 5.0 ** AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 1075 135 1055 185 1015 220 1000 265 990 325 OFF OFF CFM WATTS 1220 185 1200 240 1210 295 1210 350 1210 410 ON ON OFF CFM WATTS 1390 245 1390 320 1410 391 1410 470 1400 510 OFF ON OFF ON CFM WATTS 1214 185 1210 240 1215 295 1210 350 1210 415 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1430 310 1460 355 1470 430 1460 500 1440 555 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1640 370 1665 460 1650 540 1640 615 1610 660 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1405 270 1430 310 1440 375 1440 480 1420 550 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1670 395 1675 490 1670 550 1655 630 1630 700 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1870 540 1880 635 1880 730 1845 800 1670 640 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1775 480 1800 580 1820 680 1800 750 1680 740 NORMAL ** (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 2065 755 2020 840 1945 900 1805 880 1623 800 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 2310 1000 2100 1000 2100 950 1965 890 1800 825 LOW (350 CFM/TON) ON ON OFF NORMAL (400 CFM/TON) ON ON HIGH (450 CFM/TON) ON LOW (350 CFM/TON) SW 4 NOTES: 1. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 14 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 *UD2C100B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 953 50 93 944 50 146 936 51 193 908 52 243 887 54 292 OFF CFM TEMP. RISE WATTS 1142 42 135 1141 42 200 1135 42 255 1112 43 322 1098 43 377 OFF OFF CFM TEMP. RISE WATTS 1258 38 169 1260 38 240 1256 38 302 1236 38 378 1227 39 437 LOW ON ON CFM TEMP. RISE WATTS 1312 52 188 1317 52 261 1314 52 326 1294 53 406 1287 53 468 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1577 44 301 1592 43 387 1592 43 468 1597 43 563 1582 43 644 HIGH OFF OFF CFM TEMP. RISE WATTS 1739 39 392 1761 39 486 1762 39 575 1753 39 675 1762 39 774 *UD2C100B9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.0 3.5 4.0 5.0 ** AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 1056 114 1050 173 1044 225 1019 284 1002 336 OFF OFF CFM WATTS 1199 151 1199 219 1194 277 1172 349 1161 405 ON ON OFF CFM WATTS 1342 198 1348 273 1345 340 1326 422 1320 486 OFF ON OFF ON CFM WATTS 1223 158 1224 227 1219 287 1198 361 1187 418 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1389 217 1397 294 1395 363 1377 449 1373 515 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1556 291 1570 376 1570 455 1556 549 1559 629 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1389 217 1397 294 1395 363 1377 449 1373 515 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1580 303 1595 389 1595 469 1582 565 1585 647 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1770 411 1793 507 1795 598 1787 698 1797 801 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1723 382 1744 475 1754 564 1735 663 1744 760 NORMAL ** (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1961 546 1991 652 1996 751 1991 850 2010 981 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 2199 754 2217 875 2217 983 2197 1067 1987 943 LOW (350 CFM/TON) ON ON OFF NORMAL (400 CFM/TON) ON ON HIGH (450 CFM/TON) ON LOW (350 CFM/TON) SW 4 NOTES: 1. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 15 *UD2D120A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW7 SW8 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 1007 57 114 1062 54 177 1084 53 285 1063 54 303 1063 54 350 OFF CFM TEMP. RISE WATTS 1154 50 167 1211 48 230 1211 48 277 1221 47 344 1212 48 417 OFF OFF CFM TEMP. RISE WATTS 1288 45 208 1319 44 273 1310 44 330 1349 43 410 1358 43 460 LOW ON ON CFM TEMP. RISE WATTS 1387 64 250 1421 63 320 1455 61 400 1488 60 460 1495 59 540 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1589 56 350 1637 54 440 1666 53 535 1678 53 600 1541 58 575 HIGH OFF OFF CFM TEMP. RISE WATTS 1771 50 475 1788 50 560 1804 49 650 1751 51 675 1554 57 590 *UD2D120A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.5 4 5 ** AIRFLOW SETTING (See Notes) DIP SWITCH SETTING SW1 SW2 SW3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 1195 150 1243 225 1235 275 1251 325 1251 410 OFF OFF CFM WATTS 1353 210 1403 290 1417 370 1437 425 1458 485 ON ON OFF CFM WATTS 1554 315 1572 410 1615 480 1634 570 1567 575 ON OFF OFF ON CFM WATTS 1356 200 1391 280 1399 370 1433 420 1454 510 NORMAL (400 CFM/ TON) ON OFF OFF OFF CFM WATTS 1565 320 1584 410 1633 475 1639 560 1554 575 HIGH (450 CFM/ TON) ON OFF ON OFF CFM WATTS 1766 450 1799 550 1810 650 1784 685 1590 600 LOW (350 CFM/ TON) OFF OFF OFF ON CFM WATTS 1708 420 1758 530 1759 585 1775 675 1575 585 NORMAL ** (400 CFM/ TON) OFF OFF OFF OFF CFM WATTS 1994 665 2018 775 1971 785 1814 725 1618 625 HIGH (450 CFM/ TON) OFF OFF ON OFF CFM WATTS 2247 975 2152 925 2019 860 1861 765 1693 680 LOW (350 CFM/ TON) OFF ON OFF NORMAL (400 CFM/ TON) OFF ON HIGH (450 CFM/ TON) OFF LOW (350 CFM/ TON) SW4 NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON". 1. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY SETTING. 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 16 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 *UD2D120B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING S4-3 S4-4 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 1050 45 99 1044 46 146 1035 46 208 1005 47 252 980 48 310 OFF CFM TEMP. RISE WATTS 1214 39 129 1216 39 188 1217 39 262 1192 40 252 1169 41 310 OFF OFF CFM TEMP. RISE WATTS 1288 37 147 1293 37 212 1298 37 293 1275 37 309 1254 38 373 LOW ON ON CFM TEMP. RISE WATTS 1429 48 191 1440 48 267 1453 47 363 1435 48 340 1416 48 406 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1672 41 310 1695 40 402 1722 40 528 1711 40 409 1697 40 480 HIGH OFF OFF CFM TEMP. RISE WATTS 1782 39 385 1809 38 480 1890 36 623 1835 37 565 1871 37 644 *UD2D120B9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.5 4.0 5.0 ** AIRFLOW SETTING (See Notes) DIP SWITCH SETTING EXTERNAL STATIC PRESSURE S3-1 S3-2 S3-3 S3-4 0.1 0.3 0.5 0.7 0.9 LOW (350 CFM/ TON) OFF ON OFF ON CFM WATTS 1208 128 1209 186 1210 260 1185 306 1162 370 NORMAL (400 CFM/ TON) OFF ON OFF OFF CFM WATTS 1343 162 1350 232 1358 318 1337 365 1317 433 HIGH (450 CFM/ TON) OFF ON ON OFF CFM WATTS 1477 210 1491 290 1507 391 1490 436 1472 508 LOW (350 CFM/ TON) ON OFF OFF ON CFM WATTS 1343 162 1350 232 1358 318 1337 365 1317 433 NORMAL (400 CFM/ TON) ON OFF OFF OFF CFM WATTS 1496 218 1511 300 1528 403 1511 447 1494 520 HIGH (450 CFM/ TON) ON OFF ON OFF CFM WATTS 1650 296 1671 387 1698 511 1686 548 1671 626 LOW (350 CFM/ TON) OFF OFF OFF ON CFM WATTS 1612 274 1631 363 1655 482 1642 521 1627 598 NORMAL ** (400 CFM/ TON) OFF OFF OFF OFF CFM WATTS 1858 403 1902 533 1907 624 1906 714 1871 755 HIGH (450 CFM/ TON) OFF OFF ON OFF CFM WATTS 1871 585 2126 711 2110 797 2098 888 2001 953 NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON". 1. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY SETTING. 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 17 *UD2D140A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 0.1 0.3 0.5 0.7 0.9 1090 62 130 1100 61 175 1070 63 215 1080 62 255 1060 63 290 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1230 55 180 1265 53 235 1280 53 315 1300 52 380 1300 52 455 HIGH OFF OFF CFM TEMP. RISE WATTS 1380 49 235 1405 48 290 1425 47 375 1430 47 415 1450 47 520 LOW ON ON CFM TEMP. RISE WATTS 1545 67 320 1550 67 385 1560 67 475 1560 67 540 1575 66 605 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1760 59 435 1790 58 545 1810 58 620 1800 58 695 1725 60 725 HIGH OFF OFF CFM TEMP. RISE WATTS 2000 52 615 2010 52 715 2000 52 790 1950 54 820 1800 58 775 *UD2D140A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.5 4.0 5.0 ** AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 1175 165 1165 200 1180 265 1170 320 1150 400 OFF OFF CFM WATTS 1345 225 1370 285 1400 360 1405 440 1380 490 ON ON OFF CFM WATTS 1525 295 1565 390 1585 470 1575 515 1530 585 ON OFF OFF ON CFM WATTS 1320 220 1330 275 1335 355 1300 435 1240 490 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1550 310 1580 400 1590 475 1555 540 1460 610 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1735 430 1735 510 1710 600 1670 675 1590 710 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1700 415 1725 470 1730 560 1725 640 1690 700 NORMAL ** (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1980 616 1980 710 1950 770 1885 780 1735 735 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 2190 835 2150 870 2075 890 1905 800 1735 735 LOW (350 CFM/TON) OFF ON OFF NORMAL (400 CFM/TON) OFF ON HIGH (450 CFM/TON) OFF LOW (350 CFM/TON) SW 4 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 18 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT DATA WIRING DIAGRAM From Dwg. D344249P02 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 19 PRODUCT DATA SCHEMATIC DIAGRAMS From Dwg. D344249P02 20 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT DATA FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES M SEE HUM SEE NOTE 5 EAC SEE NOE TEE 5 S From Dwg. 21B341127 Rev. 0 FIELD WIRING DIAGRAM FOR TWO STAGE HEATING TO 115 V 1 PH., 60 HZ., POWER M SYEE EPERE SUPPL LOCAL CODES TE 5 HUM SEE NOTE 5 CEASC SEE EE NOTE 5 TE 5 From Dwg. 21B341126 Rev. 0 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 21 PRODUCT DATA FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING WITH SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341125 Rev. 1 FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341124 Rev. 1 22 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13 PRODUCT DATA FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) TO 115 V 1 PH., WER S60 EHZ., EE E YPOPER SUPPL LOCAL CODES 5 HUM SEE W ER R6 6 NOTE 5 DEAEC S SEEL NOTE 5 From Dwg. 21B341128 Rev. 0 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 23 24 DATA SUBJECT TO CHANGE WITHOUT NOTICE 13-1/16" 15-5/16" 24-1/2" 9-5/8" B 21" 17-1/2" A * - First Letter May Be "A" or "T" ** - Suffix Letters May Be "K" (0 Through 9) *UD2C080A9V4V** *UD2C100A9V5V** *UD2C080B9V4V** *UD2C100B9V5V** *UD2D120A9V5V** *UD2D140A9V5V** *UD2D120B9V5V** *UD2B060A9V3V** *UD2B080A9V3V** *UD2B100A9V3V** MODEL (ALL DIMENSIONS ARE IN INCHES) C 23-1/4" 19-3/4" 16-1/4" TUD-9V OUTLINE DRAWING 23" 19-1/2" 16" D From Dwg. C341699 PRODUCT DATA 22-1650-13 22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 25 PRODUCT DATA Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change the design and specifications without notice. Technical Literature - Printed in U.S.A. Trane 6200 Troup Highway Tyler, TX 75707
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 26 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:cda6a338-2292-40fa-8ffa-61f0cd6915b1 Producer : Adobe PDF Library 9.9 Trapped : False Acces flag : F Alt order nbr : Alt order nbr type : Bw color : B Date published : 11/01/2011 Dept id : 54 Topic focused id : TRANE|EN Price : 0 Cur flag : T Lit class id : PL Lit length : 26 Lit order nbr : 22-1650-13 Lit type id : PRD Media id : ELO Model : TUD Prod class : UN Prod family id : 105 Prod : FURN Restrct flag : F Source date : nulldate Source filename : Stocking loc id : None Supceded by : Supceded by date : 02/01/2008 Unit flag : T Branding : Trane Lol language : EN Object id : 090102b182a98ea1 Object name : 22-1650-13_11012011 Chronicle id : 090102b182242a9b Filename : 82a98ea1.pdf Abstract : Contains Information on the XV 80 furnace. TUD-9V Models Features and benefits- standard and optional equipment, general data - product specifications, performance data, schematic diagrams, field wiring diagrams, outline drawing Hist model : TUD2B060A9V3VB|TUD2C080A9V4VB|TUD2B100A9V3VB|TUD2C100B9V5VB|TUD2D120B9V5VB|TUD2B080A9V3VB|TUD2C080B9V4VB|TUD2C100A9V5VB|TUD2D120A9V5VB|TUD2D140A9V5VB Topic related id : TRN-FLD|SYS-DSN|STARTUP|SERVICER|SERV|RRR|OWN/DEV|OPER|INST|DSGN Create Date : 2011:11:18 11:17:46-06:00 Modify Date : 2011:11:29 16:41:10-06:00 Metadata Date : 2011:11:29 16:41:10-06:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Instance ID : uuid:a8348636-194f-4819-aad2-73ffc44c48ef Rendition Class : proof:pdf Document ID : adobe:docid:indd:fbadfd85-a3bf-11df-acf7-893be6199ab3 Original Document ID : adobe:docid:indd:fbadfd85-a3bf-11df-acf7-893be6199ab3 Derived From Instance ID : fbadfd84-a3bf-11df-acf7-893be6199ab3 Derived From Document ID : adobe:docid:indd:479a3c6a-a334-11df-b0b9-8e277e6b536f History Action : saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:F5508B4EFB11E111B83387B5860E372F, xmp.iid:F6508B4EFB11E111B83387B5860E372F, xmp.iid:D9AFD5E20412E111B83387B5860E372F, xmp.iid:DAAFD5E20412E111B83387B5860E372F, xmp.iid:0FB657FA0412E111B83387B5860E372F, xmp.iid:FD8D41610512E111B83387B5860E372F, xmp.iid:EE36DC330912E111B83387B5860E372F History When : 2011:11:18 09:38:05-06:00, 2011:11:18 09:38:05-06:00, 2011:11:18 10:46:39-06:00, 2011:11:18 10:46:39-06:00, 2011:11:18 10:49:08-06:00, 2011:11:18 10:50:11-06:00, 2011:11:18 11:17:33-06:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata N Pages : 26 Doc Change Count : 14 Format : application/pdf Title : 22-1650-13 11/01/2011 Trane Product Data Upflow-Horizontal Two-Stage Variable Speed Gas-Fired Furnace XV 80 TUD-9V Models Two-Stage Fan Assisted Combustion System Tagged PDF : Yes Creator : Adobe InDesign CS5 (7.0.4) Acces Flag : F Alt Order Nbr : Alt Order Nbr Type : Bw Color : B Hist Model : TUD2B060A9V3VB|TUD2C080A9V4VB|TUD2B100A9V3VB|TUD2C100B9V5VB|TUD2D120B9V5VB|TUD2B080A9V3VB|TUD2C080B9V4VB|TUD2C100A9V5VB|TUD2D120A9V5VB|TUD2D140A9V5VB Date Published : 11/01/2011 Dept Id : 54 Topic Focused Id : TRANE|EN Cur Flag : T Lit Class Id : PL Lit Length : 26 Lit Order Nbr : 22-1650-13 Lit Type Id : PRD Media Id : ELO Prod Class : UN Prod Family Id : 105 Topic Related Id : TRN-FLD|SYS-DSN|STARTUP|SERVICER|SERV|RRR|OWN/DEV|OPER|INST|DSGN Restrct Flag : F Source Date : nulldate Source Filename : Stocking Loc Id : None Supceded By : Supceded By Date : 02/01/2008 Unit Flag : T Lol Language : EN Object Id : 090102b182a98ea1 Object Name : 22-1650-13_11012011 Chronicle Id : 090102b182242a9bEXIF Metadata provided by EXIF.tools