Trane Voyager 12 5 To 25 Tons Catalogue Voyager™, R 410A 15 — 50 Hz
2015-04-02
: Trane Trane-Voyager-12-5-To-25-Tons-Catalogue-684200 trane-voyager-12-5-to-25-tons-catalogue-684200 trane pdf
Open the PDF directly: View PDF .
Page Count: 100
Download | |
Open PDF In Browser | View PDF |
Product Catalog Voyager™ — TS*/YS*/WS* Packaged Cooling, Gas/Electric & Heat Pump 15–25 Tons, 50 Hz August 2012 RT-PRC034-EN Introduction Packaged Gas/Electric Packaged Cooling/Heat Pump Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete line of Packaged Rooftop products available in the market today. Trane was the first to introduce the Micro—microelectronic unit controls—and has continued to improve and revolutionize this design concept. The ReliaTel control platform offers the same great features and functionality as the original Micro, with additional benefits for greater application flexibility. Voyager continues to provide the highest standards in quality and reliability, comfort, ease of service, and the performance of Trane light commercial products. Trane customers demand products that provide exceptional reliability, meet stringent performance requirements, and are competitively priced. Trane delivers with Voyager. Voyager features cutting edge technologies: reliable compressors, Trane engineered ReliaTel controls, computer-aided run testing, and Integrated Comfort™ Systems. So, whether you’re the contractor, the engineer, or the owner you can be certain Voyager Products are built to meet your needs. Trademarks and the logo, Frostat, Integrated Comfort, ReliaTel, Tracer, are trademarks of in the United States and other countries. All trademarks referenced in this document are the trademarks of their respective owners. Revision Summary RT-PRC034-EN (20 August 2012) • New configurable model number • New optional features: Condensate Overflow Switch, MERV 8 and Filter Removal Tool, Stainless Steel Drain Pan • Updated Features/Benefits, Model Number Description, General Data, Electrical Data, Mechanical Specifications © 2012 Trane All rights reserved RT-PRC034-EN Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Other Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Variety of Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Other Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Application Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Selection Procedure (SI/IP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 SI Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 IP Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Model Number Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Typical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Jobsite Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Factory Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Factory or Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 RT-PRC034-EN 3 Features and Benefits Figure 1. Factory installed options J C E F D K B G I M H A A Foil-Faced Insulation H Available in R-410A refrigerant B Quick Adjust Idler Pulley I Hinged Access Doors C ReliaTel™ Microprocessor Controls J Single Side Service D Colored and Numbered Wiring K Smoke Detector E Low Ambient Cooling to Zero° F L F High and Low Pressure Switches M Clogged Filter Switch G Scroll Compressors (R-410A) L N Fan Failure Switch N Through-the-Base Gas Piping Standard Features • • • • • • • • • • • • • • • • • • • • • • • 4 2” throwaway filters provided on 15–25 ton units Anti-Short Cycle Timer Belt Drive Motors Colored and Numbered Wiring Crankcase Heaters Dedicated Airflow Discharge Line Thermostat Easy Access Low Voltage Terminal Board (LTB) Foil-Faced and Edge Captured Insulation High Efficiency Drum and Tube Heat Exchanger High Efficiency Gas Heat with Hot Surface Ignition High Pressure Cutout IAQ Sloped Condensate Drain Pan Liquid Line Refrigerant Drier Low Ambient Cooling to 0°F Microchannel Type Condenser Coils (Major Design Sequence F, T and Y Units Only) Operating Charge of R-410A Patented Hybrid Condenser Coil for Easy cleaning Phase Monitor Provisions for Through-the-Base Gas and Condensate Drain Connections Quick Access Panels Quick Adjust Idler Arm Pulley ReliaTel™ Microprocessor Controls RT-PRC034-EN Features and Benefits • • • • • Single Point Power Single Side Service Standardized Components Trane Built Scroll Compressors U-shaped Airflow Pattern Options Factory Installed Options*10 • • • • • • • • • • • 2" MERV 8 or MERV 13 Filters with Filter Removal Tool Black Epoxy Pre-Coated Coils4, 11 CO2 Sensor Wiring (Wiring Only) Complete Coat™ Microchannel Condenser Coil Condensate Overflow Switch Hinged Access Doors Stainless Steel Drain Pan Stainless Steel Heat Exchanger with 10 year warranty4 Through the Base Electrical Access Through the Base Electrical with Circuit Breaker8, 9 Through the Base Electrical with Disconnect Switch5, 8, 9 Factory* or Field Installed Options10 Note: *Some Factory Installed Options (FIOPS) available for Downflow Air Discharge units only. Please verify with ordering system for availability. Explanation of Notes 1–10 located on page 23 following Model Number Description. • • • • • • • • Clogged Filter/Fan Failure Switch2, 4 Discharge Air Sensing Kit2, 4 Economizer - Downflow Electric Heaters4, 6, 9 Frostat2, 4 LonTalk® Communications Interface (LCI)4 ReliaTel™ Options Module7 Trane Communications Interface (TCI)1, 4 Field Installed Options • • • • • • • • • • • • • • • • RT-PRC034-EN Barometric Relief CO2 Sensor Digital Display Zone Sensor Economizer - Horizontal High and Low Static Drive Kits LP Conversion Kit Manual Outside Air Damper Motorized Outside Air Dampers Oversized Motors Reference or Comparative Enthalpy3, 4 Remote Potentiometer Roof Curb (Downflow Only) Thermostat Tool-less Hail Guards Ventilation Override Accessory2 Zone Sensors and Remote Zone Sensors 5 Features and Benefits Other Benefits • • • • • • • • Cabinet Design Ensures Water Integrity Ease of Service, Installation and Maintenance Mixed Model Build Enables “Fastest in the Industry” Ship Cycle Times Outstanding Airflow Distribution ReliaTel™ Controls benefits Rigorous Testing Unmatched Product Support Varitrac Standard Features Anti-Short Cycle Timer (Standard with ReliaTel™) Provides a 3 minute minimum “ON” time and 3 minute “OFF” time for compressors to enhance compressor reliability by assuring proper oil return. Colored And Numbered Wiring Save time and money tracing wires and diagnosing the unit. Compressors Microchannel Condenser Coil Microchannel Flat Tube Header (top removed) Ribbon Fin Voyager contains the best compressor technology available to achieve the highest possible performance. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on all models. 6 Microchannel coils have better heat transfer performance due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond. Microchannel condenser coil can reduce system refrigerant charge by up to 50% (potential LEED credit) because of smaller internal volume, which can lead to better compressor reliability. Compact all aluminum microchannel coils also help to reduce the unit weight. All-aluminum construction improves recyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. RT-PRC034-EN Features and Benefits Condenser Coil Controls—ReliaTel ReliaTel™ microprocessor controls provide unit control for heating, cooling and ventilating utilizing input from sensors that measure indoor and outdoor temperature and other zone sensors. ReliaTel also provides outputs for building automation systems and expanded diagnostics. For a complete list of ReliaTel offerings, refer to “Other Benefits,” p. 12. Conversionless Units Voyager boasts a patentpending 1+1+1 condenser coil, permanently gapped for easy cleaning. The dedicated design units (either downflow or horizontal) require no panel removal or alteration time to convert in the field—a major cost savings during installation. Horizontal units come complete with duct flanges so the contractor doesn’t have to field fabricate them. These duct flanges are a time and cost saver. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions. These are standard on all Voyager models. Discharge Line Thermostat A bi-metal element discharge line thermostats installed as a standard option on the discharge line of each system. This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Easy Access Low Voltage Terminal Board Foil Faced Insulation Voyager’s Low Voltage Terminal Board is external to the electrical control cabinet. It is extremely easy to locate and attach the thermostat wire and test operation of all unit functions. This is another cost and time saving installation feature. All panels in the evaporator section of the unit have cleanable foil-faced insulation. All edges are either captured or sealed to ensure no insulation fibers get into the airstream. Heat Exchanger—Drum and Tube The cabinet (pictured right) features a drum and tube heat exchanger that is manufactured using aluminized steel with stainless steel components for maximum durability. The requirement for cycle testing of heat exchangers is 10,000 cycles by ANSI Z21.47. This is the standard required by both UL and AGA for cycle test requirements. RT-PRC034-EN Forced Combustion Blower Negative Pressure Gas Valve Hot Surface Ignitor 7 Features and Benefits The drum and tube design has been tested and passed over 150,000 cycles, which is over 15 times the current ANSI cycling requirements. The negative pressure gas valve will not allow gas flow unless the combustion blower is operating. This is one of our unique safety features. The forced combustion blower supplies pre-mixed fuel through a single stainless steel burner screen into a sealed drum where ignition takes place. It is more reliable to operate and maintain than a multiple burner system. The hot surface ignitor is a gas ignition device which doubles as a safety device utilizing a continuous test to prove the flame. The design is cycle tested at the factory for quality and reliability. Our gas/electric rooftops exceed all California seasonal efficiency requirements and perform even better than the California NOx emission requirements. Low Ambient Cooling All Voyager microprocessor units have cooling capabilities down to 0°F as standard. Low Voltage Connections The wiring of the low voltage connections to the unit and the zone sensors is as simple as 1-1, 2-2, and 3-3. This simplified system makes it easy for the installer to wire. Motors All indoor fan motors are belt drive as standard. Pressure Cutouts Low and high pressure cutouts are standard on all Voyager models. Phase Monitor The Phase Monitor is a three-phase line monitor module that protects against phase loss, phase reversal and phase unbalance. It is intended to protect compressors from reverse rotation. It has an operating input voltage range of 190–600 Vac, and LED indicators for ON and FAULT. There are no field adjustments and the module will automatically reset from a fault condition. Quick-Access Panels Remove three or more screws for access to the standardized internal components and wiring. Quick-Adjust Slider Plate With the Quick-Adjust Slider Plate, the belt and sheaves can be quickly adjusted without moving the mounted fan motor. The result is a major savings in time and money. Single Point Power A single electrical connection powers the unit. Single Side Service Single side service is standard on all units. Sloped Drain Pans Every Voyager unit has a non-corrosive, sloped drain pan made of pre-painted steel and standard on all units. 8 RT-PRC034-EN Features and Benefits Standardized Components Components are placed in the same location on all Voyager units. Familiarize yourself with one Voyager and you are familiar with every Voyager. Due to standardized components throughout the Voyager line, contractors/owners can stock fewer parts. Through the Base Condensate Every unit includes provisions for through the base condensate drain connections. This allows the drain to be connected through the roof curb instead of a roof penetration. Variety of Options1 Factory Installed Options Black Epoxy Pre-Coated Coils (W Units Only) The pre-coated coils are an economical option for protection in mildly corrosive environments. Circuit Breaker (Required with Through-the-Base Electrical) This option is a factory installed thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. Available on all models. CO2 Sensor Wiring This is the unit wiring for field installed C02 sensors. Factory-installed C02 sensor wiring saves time and ensures proper unit connections for the field installed C02 sensor kits. Complete Coat™ Condenser Coil (T/Y Units Only) The cathodic epoxy type electrodisposition coating is formulated for high edge build to a number of different types of heat exchangers. The coating is selected to provide excellent resistance and durability to corrosive effects of alkalies, acids, alcohols, petroleum, seawater, salt air, and corrosive environments. This coating shall be available on microchannel condenser coils. Condensate Overflow Switch A condensate overflow switch is available to shut the unit down in the event that the condensate drain line becomes clogged. This option protects the unit from water overflowing from the drain pan and entering the base of the units. Disconnect Switch (Required with Through-the-Base Electrical) Factory installed three-pole, molded case, disconnect switch with provisions for through the base electrical connections are available. Available on all models. Codes require a method of assured unit shutdown for servicing. Field-installed disconnects sometimes interfere with service access. Factory installation of unit disconnects reduces costs, assures proper mounting and provides the opportunity to upgrade to unit circuit breaker protection. 1 Refer to Model Number Description for option availability. RT-PRC034-EN 9 Features and Benefits High Efficiency Filtration Voyager units offer a variety of high efficiency filtration options. MERV 8 and MERV 13 filters provide additional filtration beyond the capabilities of typical 2” throwaway filters. Also, when MERV 8 or MERV 13 filters are ordered, units come equipped with a filter removal tool. Hinged Access Doors These doors permit easy access to the filter, fan/heat, and compressor/control sections. They reduce the potential roof damage from screws or sharp access door corners. Stainless Steel Drain Pan For excellent corrosion and oxidation resistance, the optional stainless steel drain pan provides a cleanable surface that complement other IAQ solutions such as high efficiency filtration (MERV 8 or 13), or demand control ventilation (CO2). Stainless Steel Heat Exchanger The optional stainless steel heat exchanger is constructed of 304 stainless steel. It is resistant to corrosion and oxidation and easy to clean. The high strength to weight ratio allows for high ventilation rates with gas units. With this option, a 10-year stainless steel heat exchanger warranty is standard. Through-the-Base Electrical Utility Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of downflow units, and through the front of horizontal units. Option will allow for field installation of liquid-tight conduit and an external field installed disconnect switch. Factory provided through the base openings simplify wiring and piping. Because these utility openings frequently minimize the number of roof penetrations, the integrity of roofing materials is enhanced. Factory or Field Installed Options1 Clogged Filter/Fan Failure Switch A dedicated differential pressure switch is available to achieve active fan failure indication and/or clogged filter indication. These sensors allow a zone sensor service light or Integrated Comfort System to indicate a dirty filter or a fan that’s not working. The field installation charges for these valuable feedback devices often eliminate them from consideration. Factory installation can make such features a good investment. Discharge Air Sensing Kit Provides true discharge air sensing in heating models. The kit is functional only with the ReliaTel™ Options Module. Economizer - Downflow Economizers are equipped with either dry bulb or reference or comparative enthalpy sensing. These economizers provide free cooling as the outdoor temperature and/or humidity decreases. Correctly installed, they offer a valuable energy savings. 1 Refer to Model Number Description for option availability. 10 RT-PRC034-EN Features and Benefits Electric Heaters Electric heat modules are available within the basic unit. If ordering the Through the Base Electrical option with an Electrical Heater, the heater must be factory installed. Frostat™ This capillary bulb embedded in the face of the evaporator coil monitors coil temperature to prevent evaporator icing and protect the compressor. Recommended for applications with low leaving air temperatures, low airflow and or high latent load applications. LonTalk® Communications Interface The LonTalk communications interface allows the unit to communicate as a Tracer™LCI-V device or directly with generic LonTalk Network Building Automation System Controls. Motors Factory or field installed oversized motors available for high static applications are available. Oversized Motors Factory or field installed oversized motors available for high static applications. Reference or Comparative Enthalpy Measures and communicates humidity while maximizing comfort control. Trane Communication Interface (TCI) Available factory or field installed. This module when applied with the ReliaTel™ easily interfaces with Trane’s Integrated Comfort™ System. *Refer to Model Number Description for option availability. Field Installed Options1 Barometric Relief Designed to be used on downflow units, barometric relief is an unpowered means of relieving excess building pressure. CO2 Sensor - Demand Control Ventilation (DCV) Demand-controlled ventilation (DCV) is a control strategy that responds to the actual demand (need) for ventilation by regulating the rate at which the HVAC system brings outdoor air into the building. A CO2 sensor measures the concentration (parts per million, ppm) of CO2 (Carbon Dioxide) in the air. As the CO2 concentration changes, the outside air damper modulates to meet the current ventilation needs of the zone. The CO2 sensor kit is available as a field installed accessory. Note: Choose factory-installed CO2 sensor wiring option to save time and ensure proper unit connections for the field installed CO2 sensor kits. Dampers 0–25 percent manual or 0–50 percent motorized outside air dampers are available. Digital Display Zone Sensor The Digital LCD (Liquid Crystal Display) zone sensor has the look and functionality of standard zone sensors. This sensor should be utilized with ReliaTel™ controls. 1 Refer to Model Number Description for option availability. RT-PRC034-EN 11 Features and Benefits Economizer - Horizontal Economizers are equipped with either dry bulb or reference or comparative enthalpy sensing. These economizers provide free cooling as the outdoor temperature and/or humidity decreases. Correctly installed, they offer a valuable energy savings. High Static Drive Available on many models, this high static drive accessory extends the capability of the standard motor. Avoid expensive motors and operating costs by installing this optimized sheave accessory. LP Conversion Kit Provided for field conversion of gas/electric units from Natural gas to Propane. Remote Potentiometer When properly installed in the economizer control circuitry, this accessory provides a remote variable resistance to enable the operator to adjust the minimum damper position. Roof Curbs Available for downflow units. Only two roof curbs for the entire Voyager line simplifies curb selection. Tool-less Hail Guards Tool-less, hail protection quality coil guards shall be field-installed for condenser coil protection. This option protects the condenser coil from vandalism and/or hail damage. Ventilation Override Accessory With the Ventilation Override Accessory installed, the unit can be set to transition to up to three different preprogrammed sequences for Smoke Purge, Pressurization, and Exhaust. The transition occurs when a binary input on the RTOM is closed (shorted). This would typically be a hard wired relay output from a smoke detector or fire control panel. Zone Sensors/Thermostats Available in programmable, automatic and manual styles. Note: Zone sensor required for units configured for Single Zone VAV indoor fan system control to enable Single Zone VAV functionality. Other Benefits Airflow Distribution Airflow is outstanding. The Voyager can replace an older machine with old ductwork and, in many cases, improve the comfort through better air distribution. The U-shaped airflow allows for improved static capabilities. Cabinet Integrity For added water integrity, Voyager has a raised 1 1/8” lip around the supply and return of the downflow units to prevent water from blowing into the ductwork. 12 RT-PRC034-EN Features and Benefits Easy to Install, Service and Maintain Because today’s owners are very cost-conscious when it comes to service and maintenance, the Trane Voyager was designed with direct input from service contractors. This valuable information helped to design a product that would get the serviceman off the job quicker and save the owner money. Voyager does this by offering outstanding standard features enhanced by a variety of factory and field installed options, multiple control options, rigorously tested proven designs and superior product and technical support. Outstanding Airflow Distribution Airflow is outstanding. The Voyager can replace an older machine with old ductwork and, in many cases, improve the comfort through better air distribution. ReliaTel Controls Benefits ReliaTel™ controls provide unit control for heating, cooling and ventilating utilizing input from sensors that measure outdoor and indoor temperature. ReliaTel Control Logic Enhances Quality and Reliability – prevents the unit from short cycling, considerably improving compressor life. – ensures that the compressor will run for a specific amount of time which allows oil to return for better lubrication, enhancing the reliability of the compressor. Voyager with ReliaTel™ reduces the number of components required to operate the unit, thereby reducing possibilities for component failure. ReliaTel Makes Installing and Servicing Easy ReliaTel™ eliminates the need for field installed antishortcycle timer and time delay relays. ReliaTel™ controls provide these functions as an integral part of the unit. The contractor no longer has to purchase these controls as options and pay to install them. The wiring of the low voltage connections to the unit and the zone sensors is as easy as 1-1, 2-2, and 3-3. This simplified system makes wiring easier for the installer. ReliaTel™ ReliaTel Makes Testing Easy ReliaTel™ requires no special tools to run the Voyager unit through its paces. Simply place a jumper between Test 1 and Test 2 terminals on the Low Voltage Terminal Board and the unit will walk through its operational steps automatically. The unit automatically returns control to the zone sensor after stepping through the test mode a single time, even if the jumper is left on the unit. As long as the unit has power and the “system on” LED is lit, ReliaTel is operational. The light indicates that the controls are functioning properly. ReliaTel features expanded diagnostic capabilities when utilized with Trane Integrated Comfort™ Systems. Some zone sensor options have central control panel lights which indicate the mode the unit is in and possible diagnostic information (dirty filters for example). Other ReliaTel Benefits The ReliaTel™ built-in anti-shortcycle timer, time delay relay and minimum “on” time control functions are factory tested to assure proper operation. RT-PRC034-EN 13 Features and Benefits ReliaTel softens electrical “spikes” by staging on fans, compressors and heaters. Intelligent Fallback is a benefit to the building occupant. If a component goes astray, the unit will continue to operate at predetermined temperature setpoint. Intelligent Anticipation is a standard ReliaTel feature. It functions continuously as ReliaTel and zone sensor(s) work together in harmony to provide much tighter comfort control than conventional electro-mechanical thermostats. The same ReliaTel Board fits all Voyager Packaged Gas/Electrics, Cooling, and Heat Pump models. This provides standardization of parts for contractors. Less money is tied up in inventory with ReliaTel. Rigorous Testing All of Voyager’s designs were rigorously rain tested at the factory to ensure water integrity. Actual shipping tests were performed to determine packaging requirements. Units were test shipped around the country to determine the best packaging. Factory shake and drop tests were used as part of the package design process to help assure that the unit arrives at the job site in top condition. Rigging tests include lifting a unit into the air and letting it drop one foot, assuring that the lifting lugs and rails hold up under stress. The evaporator and condenser coils are leak tested at 225 psig and pressure tested to 450 psig. All parts are inspected at the point of final assembly. Sub-standard parts are identified and rejected immediately. Every unit receives a 100 percent unit run test before leaving the production line to make sure it lives up to rigorous Trane requirements. Voyager units incorporate either a one piece top or the Trane-Tite-Top (T3). Each part of the top (either two or three pieces) overlaps in such a way that water cannot leak into the unit. These overlapped edges are gasketed and sealed to ensure superior water integrity. Unmatched Support Trane Sales Representatives are a Support Group that can assist you with: • Product • Application • Service • Training • Special Applications • Specifications • Computer Programs and much more VariTrac—Building Automation System When Trane’s changeover VAV System for light commercial applications is coupled with Voyager, it provides the latest in technological advances for comfort management systems and can allow thermostat control in every zone served by VariTrac. 14 RT-PRC034-EN Application Considerations Application of this product should be within the cataloged airflow and cooling considerations. Barometric Relief This product line offers an optional barometric relief damper for use in conjunction with economizer option. This accessory consists of gravity dampers which open with increased pressure. As the building air pressure increases, the pressure in the unit return air section also increases, opening the dampers and relieving the conditioned space. Notes: • The effectiveness of barometric relief damper during economizing operation is system related. • Pressure drop of the return air system should be considered to control building pressurization. Black Epoxy Coil The coils are manufactured with a thermoset, vinyl coating that is bonded to the aluminum fin stock prior to the fin stamping process. These coils are an economical option for protection in mildly corrosive environments. Note: Not to be used where seacoast applications exist. Clearance Requirements The recommended clearances identified with unit dimensions should be maintained to ensure adequate serviceability, maximum capacity and peak operating efficiency. Actual clearances which appear inadequate should be reviewed with the local Trane sales personnel. Complete Coat™ Microchannel Condenser Coil The cathodic epoxy type electrodisposition coating is formulated for high edge build to a number of different types of heat exchangers. The coating is selected to provide excellent resistance and durability to corrosive effects of alkalies, acids, alcohols, petroleum, seawater, salty air and other corrosive environments. This coating shall be available on microchannel condenser coils. Condensate Trap The evaporator is a draw-thru configuration. A trap must be field provided prior to start-up on the cooling cycle. Heating Operation The heat exchanger is manufactured with aluminized steel. To prevent condensation within the heat exchanger, do not exceed 50 percent outside air or a minimum mixed air temperature of 40°F. Optional Stainless Steel Heat Exchanger The optional stainless steel heat exchanger is manufactured with 304 stainless steel. To prevent corrosion and prolong heat exchanger reliability, the minimum mixed air temperature allowed across the heat exchanger is 20°F. Low Ambient Cooling The Voyager™ line features, with ReliaTel™ microprocessor controls, low ambient cooling down to 0°F. The following options need to be included/considered when low ambient applications are required: continuous fan operation, crankcase heaters (standard), thermal expansion valves, frostat. Contact your local Trane Representative for more assistance with low ambient cooling applications. Unit Pitch These units have sloped condensate drain pans. Units must be installed level. Any unit slope must be toward access side of the unit. RT-PRC034-EN 15 Selection Procedure (SI/IP) SI Selection Procedure Cooling Capacity Note: Cooling Capacity Procedure is the same for cooling (TS*), gas/electric (YS*) and heat pump (WS*) units. Step 1. Calculate the building’s total and sensible cooling loads at design conditions. Use the Trane calculation methods or any other standard accepted method. Factors used in unit selection: • Total Cooling Load: 40.0 kW • Sensible Cooling Load: 29.0 kW • Airflow: 8500 m3/h • Electrical Characteristics: 380-415/50/3 • Summer Design Conditions: • Entering Evaporator Coil: 27°C DB, 22°C WB, 35°C Outdoor Ambient • External Static Pressure: 127 Pa • Rooftop—downflow configuration accessories • Roof Curb • Economizer • Electric Heat Step 2. Size the equipment using Table 4, p. 30. Match the cooling loads at design conditions. Table 4, p. 30 shows that a TSD155F has a gross cooling capacity of 47.5 kW and 35.6 kW sensible capacity at 8500 m3/h and 35°C DB outdoor ambient with 27°C DB, 19°C WB air entering the evaporator. To Find Capacity at Intermediate Conditions Not in the Table: When the design conditions are between two numbers that are in the capacity table, interpolation is required to approximate the capacity. Note: Extrapolation outside of the table conditions is not recommended. 16 RT-PRC034-EN Selection Procedure (SI/IP) Step 3. In order to select the correct unit which meets the building’s requirements, the fan motor heat must be deducted from the gross cooling capacity. The amount of heat that the fan motor generates is dependent on the effort by the motor, airflow and static pressure. To determine the total unit static pressure (see Table 48, p. 56 for Static Pressure Drops Through Accessories): External Static Duct System 127 Pa Standard Filter 25mm 19 Pa Economizer (100% OA) 12 Pa Electric Heater Size 27 kW 11Pa Total Static Pressure 169 Pa Notes: 1. Reference “Heating Capacity” section on this page for determination of heater size. 2. No additional static add for gas/heat exchanger. Note: The Evaporator Fan Performance (see Table 20, p. 44) has already accounted for the pressure drop for standard filters and wet coils (see note below Table 20, p. 44). Therefore, the actual total static pressure is 169 - 19 (from Table 48, p. 56) = 150 Pa. With 8500 m3/h and 150 Pa. Table 20, p. 44 shows 1.12 kW for this unit. The formula below can be used to calculate Fan Motor Heat: Fan Motor Heat = 1.23 * Fan Power (kW) 1.23 * 1.12 kW = 1.3776 kW Now subtract the fan motor heat from the gross cooling capacity of the unit: Net Total Cooling Capacity = 47.5 - 1.37 = 46.12 Net Sensible Cooling Capacity = 35.6 - 1.37 = 34.22 Step 4. If the performance will not meet the required load of the building, total or sensible cooling load, try a selection at the next higher size unit. Heating Capacity Note: Heating capacity procedures DIFFER for cooling (TS*), gas/electric (YS*) and heat pump (WS*) units. Step 1. Calculate the building heating load using the Trane calculation form or other standard accepted method. Step 2. Size the system heating capacity to match the calculated building heating load. The following are building heating requirements: TS* cooling units: • 380 volt/three-phase Power Supply • Total heating load of 20.5 kW • Airflow of 8500 m3/h The electric heat accessory capacities are listed in Table 52, p. 62. From the table, a 26.9 kW heater at 415 volts is selected. In order to determine capacity at 380 volts, the heater voltage correction RT-PRC034-EN 17 Selection Procedure (SI/IP) factor from Table 53, p. 62 must be used. Therefore, 26.9 kW x 0.84 (voltage correction factor) = 22.59 kW. YS* gas/electric: The fuel used is natural gas with a total heating load of 30 kW. Table 2, p. 26 shows 61.1 kW and 85.5 kW input models. The output capacities of these furnaces are 49.6 kW and 69.4 kW, respectively. The low heat model with 49.6 kW output best matches the building requirements. WS* heat pumps: Total heating load of 30.0 kW. Outdoor ambient (Winter) of -9°C DB and indoor return of 21°C DB and an airflow of 8500 m3/h. The unit is using a 380 V power supply. Use the integrated portion of Table 16, p. 42 for the WC*155 to determine capacity at winter design conditions. The mechanical heating portion of the heat pump will provide 20.9 kW. Step 3. Note: This step does not apply to TS* and YS* units. WS* heat pumps: Because 22.1 kW is less than the building's required heating capacity at winter design condition, a supplementary heater must be selected. 30.0 - 20.9 = 9.1 kW From Table 62, p. 64, a 13.4 kW heater at 415 V is selected. To find the capacity at 380 V, the heater voltage correction factor from Table 63, p. 64 must be used. Therefore, 13.4 kW x 0.84 (voltage correction factor) = 11.26 kW. This heater will be adequate to do the job. Air Delivery Selection Note: Air Deliver procedures is the same for cooling (TS*), gas/electric (YS*) and heat pump (WS*) units. External static pressure drop through the air distribution system has been calculated to be 150 Pa. From Table 48, p. 56, static pressure drop through the economizer is 12 Pa and the 27 kW heater is 12 Pa (127 + 12 + 12). Enter (Table 20, p. 44) for a TSD155F at 8500 m3/h and 150 Pa static pressure. The standard motor at 566 rpm will give the desired airflow at a rated kW of 1.12. 18 RT-PRC034-EN Selection Procedure (SI/IP) IP Selection Procedure Cooling Capacity Note: Cooling Capacity Procedure is the same for cooling (TS*), gas/electric (YS*) and heat pump (WS*) units. Step 1. Calculate the building’s total and sensible cooling loads at design conditions. Use the Trane calculation methods or any other standard accepted method. Factors used in unit selection: • Total Cooling Load: 140 MBh • Sensible Cooling Load: 100 MBh • Airflow: 5000 cfm • Electrical Characteristics: 380-415/50/3 • Summer Design conditions: • Entering Evaporator Coil: 80 DB, 73 WB • Outdoor Ambient: 95 DB • External Static pressure: 0.50 in. wg • Rooftop - downflow configuration • Accessories • Roof Curb • Economizer • Electric Heat Step 2. As a starting point, a rough determination must be made of the size of the unit. The final selection will be made after examining the performance at the given conditions. Divide the total cooling load by nominal Btu/h per ton (12 MBh per ton); then round up to the nearest unit size. 140 MBh / 12 MBh = 11.6 tons Step 3. Table 5, p. 31 shows that a TSD155F has a gross cooling capacity of 162.2 MBh and 121.4 MBh sensible capacity at 5000 cfm and 95 DB outdoor ambient with 80 DB, 73 WB air entering the evaporator. To Find Capacity at Intermediate Conditions Not in the Table: When the design conditions are between two numbers that are in the capacity table, interpolation is required to approximate the capacity. Note: Extrapolation outside of the table conditions is not recommended. RT-PRC034-EN 19 Selection Procedure (SI/IP) Step 4. In order to select the correct unit which meets the building’s requirements, the fan motor heat must be deducted from the gross cooling capacity. The amount of heat that the fan motor generates is dependent on the effort by the motor, cfm and static pressure. To determine the total unit static pressure you add the external static pressure to the additional static related by the added features (see Table 49, p. 57 for Static Pressure Drops Through Accessories): External Static Duct System 0.50 wg Standard Filter 1in. 0.08 wg Economizer (100% OA) 0.05 wg Electric Heater Size 27 kW 0.05 wg Total Static Pressure 0.68 wg Notes: 1. Reference “Heating Capacity” section on this page for determination of heater size. 2. No additional static add for gas/heat exchanger. Note: The Evaporator Fan Performance Table 21, p. 44 has already accounted for the pressure drop for standard filters and wet coils (see note below Table 21, p. 44). Therefore, the actual total static pressure is 0.68 - 0.08 (from Table 49, p. 57) = 0.60 wg. With 5000 cfm and 0.60 wg, Table 21, p. 44 shows 1.50 bhp for this unit. The formula below can be used to calculate Fan Motor Heat: Fan Motor Heat = 3.15 * Fan bhp 3.15 * 1.50 = 4.725 MBh Now subtract the fan motor heat from the gross cooling capacity of the unit: Net Total Cooling Capacity = 162.2 - 4.725 = 157.475 MBh Net Sensible Cooling Capacity = 121.4 - 4.725 = 116.675 MBh Step 5. If the performance will not meet the required load of the building, total or sensible cooling load, try a selection at the next higher size unit. 20 RT-PRC034-EN Selection Procedure (SI/IP) Heating Capacity Note: Heating capacity procedures DIFFER for cooling (TS*), gas/electric (YS*) and heat pump (WS*) units. Step 1. Calculate the building heating load using the Trane calculation form or other standard accepted method. Step 2. Size the system heating capacity to match the calculated building heating load. The following are building heating requirements: TS* cooling units: 380 volt/3 phase Power Supply Total heating load of 75.0 MBh 5000 cfm The electric heat accessory capacities are listed in Table 52, p. 62. From the table, a 26.9 kW heater will deliver 91.73 MBh at 415 volts. In order to determine capacity at 380 volts, the heater voltage correction factor from Table 53, p. 62 must be used. Therefore, 91.73 MBh x 0.84 (voltage correction factor) = 77.05 MBh. YS* gas/electric: Fuel natural gas and a total heating load of 115 MBh. Table 2, p. 26 shows 208.3 MBh and 291.7 MBh input models. The output capacities of these furnaces are 169.2 MBh and 236.7 MBh respectively. The low heat model with 169.2 MBh output best matches the building requirements. WS* heat pumps: Total heating load of 100 MBh. Outdoor ambient (Winter) of 17 DB and Indoor Return of 70 DB and an airflow of 5000 cfm. The unit is using a 380 V power supply. Use the integrated portion of Table 17, p. 42 for the WC*155 to determine capacity at winter design conditions. The mechanical heating portion of the heat pump will provide 71.2 MBh. Step 3. Note: This step does not apply to TS* and YS* units. WS* heat pumps: Because 71.2 MBh is less than the building’s required heating capacity at winter design conditions, a supplementary heater must be selected. 100 MBh - 71.2 MBh = 28.8 MBh From Table 62, p. 64, a 13.4 kW heater at 415 V is selected. To find the capacity at 380 V, the heater voltage correction factor from Table 63, p. 64 must be used. Therefore, 13.4 kW x 0.84 (voltage correction factor) = 11.26 kW. This heater will be adequate to do the job. 38.3 MBh. Air Delivery Selection Note: Air Delivery procedures is the same for cooling (TS*), gas/electric (YS*) and heat pump (WS*) units. External static pressure drop through the air distribution system has been calculated to by 0.60 inches of water. From Table 49, p. 57, static pressure drop through the economizer is 0.05 and the 26.9 kW heater is 0.05 inches of water (0.50 + 0.05 + 0.05). Enter (Table 21, p. 44) for a TSD155 at 5000 cfm and 0.60 static pressure. The standard motor at 566 rpm will give the desired airflow at a rated bhp of 1.50. RT-PRC034-EN 21 Model Number Descriptions T S D 1 5 1 2 3 4 5 Digit 1 — Unit Type T = Y = W = Packaged Cooling, Electric Heat Packaged Gas/Electric Packaged Heat Pump, Electric Heat Digit 2 — Efficiency S = Standard Digit 3 — Airflow Configuration D H = = Downflow Horizontal Digit 4, 5, 6 — Nominal Gross Cooling Capacity (MBh) 5 F D R 6 7 8 9 = Without Communications Options 6 = 7 8 = = Building Automation Control Network Communications Interface 9 A = = D = E = F = Digit 16 — Hinged Service Access / Filters = = 380-415/50/3 200/50/311 Digit 9 — Unit Controls R = Reliatel Digit 10 — Heating Capacity Note: (Applicable to Digit 1 T/W models only) 0 = No Heat G = 18 kW Electric Heat K = 27 kW Electric Heat N = 36 kW Electric Heat P = 54 kW Electric Heat R = 72 kW Electric Heat Note: (Applicable to Digit 1 Y models only) H = Gas Heat - High L = Gas Heat - Low X = Gas Heat - SS Ht Ex - Low Z = Gas Heat - SS Ht Ex - High Digit 11 — Minor Design Sequence Digit 12, 13 — Service Sequence Digit 14 — Fresh Air Selection 0 A B D = = = = F = H = 22 No Fresh Air Manual Damper Motorized Damper Econ Dry Bulb w/ Barometric Relief Econ Reference Enthaply w/ Barometric Relief Econ Comparative Enthaply w/ Barometric Relief 12 0 Standard Motor Oversized Motor High Efficiency Motor Single Zone Variable Air Volume Standard Motor Multi-Speed Standard Motor Single Zone Variable Air Volume Oversized Motor Multi-Speed Oversized Motor Single Zone Variable Air Volume Standard Motor w/ Shaft Ground Ring Multi-Speed Standard Motor w/ Shaft Ground Ring Single Zone Variable Air Volume Oversized Motor w/ Shaft Ground Ring Multi-Speed Oversized Motor w/ Shaft Ground Ring Digit 7 — Major Design Sequence D T 11 = = = = = Digit 8 — Voltage Selection 10 0 1 3 6 C Round Tube Plate Fin Type Condenser Coils Microchannel Type Condenser Coils A Digit 21 — Communications Options = 15 Tons Standard Efficiency 17½ Tons Standard Efficiency 20 Tons Standard Efficiency 25 Tons Standard Efficiency A Digit 15 — Supply Fan/Drive Type/Motor B 155 = 175 = 200 = 250 = 0 0 A = = Standard Panels/Standard Filters Hinged Access/Standard Filters Digit 17 — Condenser Coil Protection Digit 22 — Refrigeration System Option 0 = 0 1 = = 0 A B C = = = = D = 5 = 6 = Digit 18 — Through The Base Provisions 7 = 0 A B C D A = B = C = D = E = Digit 20 — Convenience Outlet Option F = 0 A B G = H = 4 5 = = = = = = = Standard Coil Standard Coil With Hail Guard Black Epoxy Pre-Coated Coil Black Epoxy Pre-Coated Coil With Hail guard CompleteCoat™Condenser Coil CompleteCoat™Condenser Coil with Hail Guard No Through The Base Provisions Through The Base Electric Through The Base Gas Through The Base Electric/Gas Through The Base Access Digit 19 — Disconnect Switch/ Circuit Breaker 0 1 = = 2 = = = = No Disconnect/circuit break Unit Mounted Non-Fused Disconnect Switch Unit Mounted Circuit Breaker Without Convenience Outlet Unpowered Convenience Outlet Powered Convenience Outlet Without Smoke Detector Return Air Smoke Detector Supply Air Smoke Detector Return/Supply Air Smoke Detector Plenum Smoke Detector Digit 25 — System Monitoring Controls = = = = = = = = = Without Refrigeration Controls Frostat Digit 24 — Smoke Detector 0 1 2 3 4 0 1 2 3 Standard refrigeration system Digit 23 — Refrigeration Controls No Monitoring Controls Clogged Filter Switch Fan Failure Switch Discharge Air Sensing Clogged Filter Switch and Fan Failure Clogged Switch and Discharge Air Sensing Fan Failure Switch and Discharge Air Sensing Clogged Filter Switch, Fan Failure Switch and Discharge Air Sensing Condensate Drain Pan Overflow Switch Clogged Filter Switch and Condensate Drain Pan Overflow Switch Fan Failure Switch and Condensate Drain Pan Overflow Switch Discharge Air Sensing and Condensate Drain Pan Overflow Switch Clogged Filter Switch, Fan Failure Switch and Condensate Drain Pan Overflow Switch Clogged Filter Switch, Discharge Air Sensing Tube and Condensate Drain Pan Overflow Switch Fan Failure Switch, Discharge Air Sensing Tube and Condensate Drain Pan Overflow Switch Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing and Condensate Drain Pan Overflow Switch RT-PRC034-EN Model Number Descriptions Digit 26 - System Monitoring Controls 0 A No Monitoring Controls Demand Control Ventilation (CO2)12 Digit 27 - Unit Hardware Enhancements 0 1 No Enhancements Stainless Steel Drain Pan Options Factory Installed • • • • • • • • • • • • Black Epoxy Pre-Coated Coils4 CO2 Sensor Wiring (Wiring Only) Complete Coat Microchannel Coil Condensate Overflow Switch Hinged Access Doors MERV 8 or 13 with Filter Removal Tool Stainless Steel Drain Pan Stainless Steel Heat Exchanger with 10 year warranty4 Through the Base Electrical Access Through the Base Electrical with Circuit Breaker8, 9 Through the Base Electrical with Disconnect Switch5, 8, 9 Clogged Filter/Fan Failure Switch2, 4 Discharge Air Sensing Kit2, 4 Economizer - Downflow Electric Heaters4, 6, 9 Frostat2, 4 LonTalk® Communications Interface (LCI)4 ReliaTel Options Module7 Field Installed Options • • • • • • • • • • • • • • • • • • 3. Requires Economizer. 4. Available factory installed on downflow AND horizontal units. Verify with ordering system. 5. Cannot be fused. 6. Must be factory installed when using Through-the-Base Options. 7. Options*10 Factory* or Field Installed Options10 • • • • • • 2. Requires ReliaTel options module. Barometric Relief CO2 Sensing Digital Display Zone Sensor Dual Thermistor Remote Zone Sensor Economizer - Horizontal High and Low Static Drive Kits LP Conversion Kit Manual Outside Air Damper Motorized Outside Air Dampers Oversized Motors Reference or Comparative Enthalpy3, 4 Remote Potentiometer Roof Curb (Downflow Only) Thermostat Tool-less Hail Guards Trane Communications Interface (TCI)1, 4 Ventilation Override Accessory2 Zone and Remote Zone Sensors ReliaTel Options Module is required when ordering the following accessories (Factory- or Field-Installed Options): Clogged Filter Switch, Fan Fail Switch, Discharge Air Sensing Kit, Frostat, Ventilation Override. 8. Unit mounted disconnect and circuit breakers are mutually exclusive of each other. 9. Through-the-base electrical option or Horizontal Side Access must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat. 10. All Factory Installed Options are Built-to-Order. Check order services for estimated production cycle. 11. Available on Heat Pump (W) units only. 12. Demand Control Ventilation Option includes wiring only. The C02 sensor is a field-installed only option. Note: *Some Factory Installed Options (FIOPS) available for Downflow Air Discharge units only. Please verify with ordering system for availability. Model Number Notes 1. TCI is for use with non-VariTrac systems and VariTrac systems. RT-PRC034-EN 23 General Data Table 1. TS* general data 15–25 Tons Downflow and Horizontal Units Model TS*155FD TS*175FD TS*200FD TS*250FD ARI Gross Capacity kW (MBh) 44.8 (153) 51.2 (174.8) 62.7 (214.1) 68.3 (233.0) COP/EER(b) 3.47 / 11.8 3.51 / 12.0 3.14 / 10.7 3.10 / 10.8 7480 (4400) 9000 (5300) 10400 (6125) 12240 (7200) 44.0 (150) 49.8 (170.0) 61.0 (208.2) 66.0 (225.3) Cooling Performance(a) Nominal Airflow - m3/h (cfm) ARI Airflow - m3/h (cfm) ARI Net Capacity - kW (MBh) System Power - kW 13 14.6 20.0 21.6 12.9 14.5 19.6 21.0 2/Scroll 2/Scroll 2/Scroll 2/Scroll Compressor No./Type Sound Rating dB(c) Outdoor Coil - Type Coil Width mm (in.) Face Area - m2 (sq. ft.) Rows/Fins per inch Indoor Coil - Type Tube Size OD - in. Face Area - m2 (sq. ft.) 9.0 9.2 9.2 9.2 Microchannel Microchannel Microchannel Microchannel 25.4 (1) 25.4 (1) 25.4 (1) 25.4 (1) 3.27 (35.2) 3.27 (35.2) 3.27 (35.2) 3.27 (35.2) 1 / 20 1 / 20 1 / 20 1 / 20 Hi-Performance Hi-Performance Hi-Performance Hi-Performance 0.3125 0.3125 0.3125 0.3125 (2.42) 26 (2.42) 26 (2.42) 26 (2.42) 26 Rows/Fins per inch 3/ 15 4 / 15 4 / 15 4 / 15 Refrigerant Control Short Orifice Short Orifice Short Orifice Short Orifice 1/1.00 NPT 1/1.00 NPT 1/1.00 NPT 1/1.00 NPT Propeller Propeller Propeller Propeller 2 / 660 (26) 2 / 660 (26) 2 / 660 (26) 2 / 710(28) Drive Type/No. Speeds Direct / 1 Direct / 1 Direct / 1 Direct / 1 m3/h 15630 (9200) 18860 (11100) 18000 (10600) 19880 (11700) 2 / 250(0.33) 2 / 560(0.75) 2 / 560(0.75) 2 / 560(0.75) 925 950 950 950 FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal Drain Connection No./Size - in. Outdoor Fan - Type No. Used/Diameter - mm (in.) Airflow - (cfm) No. Motors/Power - W (HP) Motor RPM Indoor Fan - Type No. Used Diameter x Width - mm (in.) Drive Type/No. Speeds No. Motors Standard/Oversized Motor Power — W (HP) Motor RPM - Standard/Oversized 24 1 1 1 1 457x457 (18x18) 457x457 (18x18) 457x457 (18x18) 457x457 (18x18) Belt / 1 Belt / 1 Belt / 1 Belt / 1 1 1 1 1 1500(2.0) / 2200(3.0) 2200(3.0) / 3700(5.0) 2200(3.0) / 3700(5.0) 3700(5.0) / N/A 1450 / 2850 2850 / 2920 2850 / 2920 2920/N/A RT-PRC034-EN General Data TS* General Data Table 1. TS* general data (continued) 15–25 Tons Downflow and Horizontal Units Model TS*155FD TS*175FD TS*200FD TS*250FD Throwaway Throwaway Throwaway Throwaway (4)508x508x50 (4)508x635x50 (4)508x508x50 (4)508x635x50 (4)508x508x50 (4)508x635x50 (4)508x508x50 (4)508x635x50 (4)20x20x2 (4)20x25x2 (4)20x20x2 (4)20x25x2 (4)20x20x2 (4)20x25x2 (4)20x20x2 (4)20x25x2 (8)508x635x50 (8)508x635x50 (8)508x635x50 (8)508x635x50 (8)20x25x2 (8)20x25x2 (8)20x25x2 (8)20x25x2 5.2/2.7 (11.4/6) 6.5/3.4 (14.4/7.6) 6.1/3.2 (13.5/7) 4.8/4.8 (10.5/10.5) Filters—Type/Furnished Type Furnished Number Size Recommended Downflow—mm Downflow—in Horizontal—mm Horizontal—in Refrigerant Charge R-410A kg (lb)(d) (a) Cooling Performance is rated at 35°C (95°F) ambient, 26.7°C (80°F) entering dry bulb, 19.4°C (67°F) entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation ±20% of nominal airflow. Ratings shown are tested and certified in accordance with ARI Standard 210/240 or 340/360 certification program. (b) EER is rated at ARI conditions and in accordance with DOE test procedures. (c) Sound Ratings shown are tested in accordance with ARI Standard 270 or 370. (d) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. RT-PRC034-EN 25 General Data YS* General Data Table 2. YS* general data 15–25 Tons Downflow and Horizontal Units Model YS*155FD YS*175FD YS*200FD YS*250FD ARI Gross Capacity—kw (MBh)) 44.8 (153) 51.2 (174.8) 62.7 (214.1) 68.3 (233.0) COP/EER(b) 3.47 / 11.8 3.51 / 12.0 3.14 / 10.7 3.10 / 10.8 7480 (4400) 5300 6125 7175 44.0 (150) 49.8 (170.0) 61.0 (208.2) 66.0 (225.3) 13 14.6 20.0 21.6 Cooling Performance(a) Nominal Airflow—m3/h (cfm) ARI Airflow—m3/h (cfm) System Power—kW Heating Performance(c) Heating Models Low Heating Input—(MBh) High Low High Low High Low High 61.1(208.3) 85.5(291.7) 61.1(208.3) 85.5(291.7) 61.1(208.3) 97.7(333.3) 61.1(208.3) 97.7(333.3) 1st Stage (2 Stage Only)—(MBh) 42.7(145.8) 61.1(208.3) 42.7(145.8) 61.1(208.3) 42.7(145.8) 73.3(250.0) 42.7(145.8) 73.3(250.0) Heating Output—(MBh) 49.6(169.2) 69.4(236.7) 49.6(169.2) 69.4(236.7) 49.6(169.2) 79.1(270.0) 49.6(169.2) 79.1(270.0) 1st Stage (2 Stage Only)—(MBh) 34.7(118.3) 49.6(169.2) 34.7(118.3) 49.6(169.2) 34.7(118.3) 59.3(202.5) 34.7(118.3) 59.3(202.5) Steady State Efficiency % 23.7(81.0) 23.7(81.0) 23.7(81.0) 23.7(81.0) 23.7(81.0) 23.7(81.0) 23.7(81.0) 23.7(81.0) 1 1 1 1 1 1 1 1 1/2 3/4 1/2 3/4 1/2 3/4 1/2 3/4 Numbers of Gas Heat Stages Number of Gas Burners Gas Connection Pipe Size—in. Compressor Number/Type Sound Rating dB(d) 2/Scroll 2/Scroll 2/Scroll 2/Scroll 9.0 9.2 9.2 9.2 Microchannel Microchannel Microchannel Microchannel Outdoor Coil Type Coil Width—mm (in.) 25.4 (1) 25.4 (1) 25.4 (1) 25.4 (1) 3.27 (35.2) 3.27 (35.2) 3.27 (35.2) 3.27 (35.2) 1 / 20 1 / 20 1 / 20 1 / 20 Hi-Performance Hi-Performance Hi-Performance Hi-Performance 0.3125 0.3125 0.3125 0.3125 (2.42) 26 (2.42) 26 (2.42) 26 (2.42) 26 Rows/Fins per inch 3/15 4/15 4/15 4/15 Refrigerant Control Short Orifice Short Orifice Short Orifice Short Orifice 1/1.00 NPT 1/1.00 NPT 1/1.00 NPT 1/1.00 NPT Propeller Propeller Propeller Propeller 2/660 (26) 2/660 (26) 2/660 (26) 2/710 (28) Direct/1 Direct/1 Direct/1 Direct/1 15630 (9200) 18860 (11100) 18000 (10600) 19880 (11700) 2/250(0.33) 2/560(0.75) 2/560(0.75) 2/560(0.75) 925 950 950 950 Face Area—m3 (sq. ft.) Rows / Fins per inch Indoor Coil Type Tube Size (in.) ID Face Area—m3 (sq. ft.) Drain Connection Number/ Size—in. Outdoor Fan Type Number Used/Diameter—mm (in.) Drive Type/No. Speeds Airflow—m3/h (CFM) Number Motors/W (HP) Motor RPM 26 RT-PRC034-EN General Data YS* General Data Table 2. YS* general data (continued) 15–25 Tons Downflow and Horizontal Units Model YS*155FD YS*175FD YS*200FD YS*250FD FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal 1 1 1 1 457x457 (18x18) 457x457 (18x18) 457x457 (18x18) 457x457 (18x18) Belt / 1 Belt / 1 Belt / 1 Belt / 1 Indoor Fan Type Number Used Diameter x Width—mm (in.) Drive Type/No. Speeds Number Motors 1 1 1 1 Motor W (HP) (Standard/Oversized) 1500 (2.0) / 2200 (3.0) 2200 (3.0) / 3700 (5.0) 2200 (3.0) / 3700 (5.0) 3700 (5.0) / N/A Motor RPM (Standard/Oversized) 1450 / 2850 2850 / 2920 2850 / 2920 2920/N/A Throwaway Throwaway Throwaway Throwaway (4)508x508x50 (4)508x508x50 (4)508x508x50 (4)508x508x50 Filters Type Furnished Number Size Recommended Downflow—mm Downflow—in. Horizontal—mm Horizontal—in. (4)508x635x50 (4)508x635x50 (4)508x635x50 (4)508x635x50 (4)20x20x2 (4)20x25x2 (4)20x20x2 (4)20x25x2 (4)20x20x2 (4)20x25x2 (4)20x20x2 (4)20x25x2 (8)508x635x50 (8)508x635x50 (8)508x635x50 (8)508x635x50 (8)20x25x2 (8)20x25x2 (8)20x25x2 (8)20x25x2 5.2/2.7 (11.4/6) 6.5/3.4 (14.4/7.6) 6.1/3.2 (13.5/7) 4.8/4.8 (10.5/10.5) Refrigerant Charge R-410A kg (lb)(e) (a) Cooling Performance is rated at 35°C (95°F) ambient, 26.7°C (80°F) entering dry bulb, 19.4°C (67°F) entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation ±20% of nominal airflow. Ratings shown are tested and certified in accordance with ARI Standard 210/240 or 340/360 certification program. (b) EER is rated at ARI conditions and in accordance with DOE test procedures. (c) Heating performance unit settings and data were established under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 610 meters (2000 ft.). For elevations above 610 meters (2000 ft.), ratings should be reduced at the rate of 4% for each 305 meters (1000 ft.) above sea level. (d) Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (e) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. RT-PRC034-EN 27 General Data WS* General Data Table 3. WS* general data 15–20 Tons Downflow and Horizontal Units Model WS*155ED, ET WS*200ED, ET 44.1 (150.7) 62.9 (214.8) Cooling Performance(a) ARI Gross Capacity—kW (MBh) COP/EER(b) 3.3 (11.3) 2.9 (9.9) 8500 (5000) (11890) 7000 ARI Airflow—m3/h (cfm) 8500 (5000) (11890) 7000 ARI Net Capacity—kW (MBh) 43.2 (147.5) 61.0 (208.5) 13.1 21.0 41.8 (142.7) 61.4 (209.6) 3.8 3.6 11.0 17.2 2 / Scrolls 2 / Scrolls 9.0 9.2 Type Hi-Performance Hi-Performance Refrigerant Control Expansion Valve Expansion Valve Tube Size (in.) OD 0.3125 0.3125 3.3 (35.2) 4.0 (42.53) 3 / 16 3 / 16 Hi-Performance Hi-Performance Nominal Airflow—m3/h (cfm) System Power—kW Heating Performance(a) High Temperature Capacity—kW (MBh) COP System Power—kW Compressor Number/Type Sound Rating dB(c) Outdoor Coil Face Area-m3 (sq. ft.) Rows / Fins per inch Indoor Coil Type Tube Size (in.) ID Face Area-m3 (sq. ft.) Rows / Fins per inch Refrigerant Control Drain Connection Number/Size (in.) 0.3125 0.3125 2.4 (26) 2.9 (31.42) 4 / 15 4 / 15 Short Orifice Short Orifice 1/1.00 NPT 1/1.00 NPT Outdoor Fan Type Number Used/Diameter—mm (in.) Drive Type/No. Speeds Airflow—m3/h (CFM) Number Motors/W (HP) Motor RPM 28 Propeller Propeller 2 / 660 (26) 2 / 710(28) Direct / 1 Direct / 1 15300 (9000) 20900 (12300) 2 / 250 (0.33) 2 / 560 (0.75) 925 950 RT-PRC034-EN General Data WS* General Data Table 3. WS* general data (continued) 15–20 Tons Downflow and Horizontal Units Model WS*155ED, ET WS*200ED, ET FC Centrifugal FC Centrifugal Indoor Fan Type Number Used Diameter x Width—mm (in.) Drive Type/No. Speeds Number Motors 1 1 457x457 (18x18) 457x457 (18x18) Belt / 1 Belt / 1 1 1 1500 (2.0) / 2200 (3.0) 2200 (3.0) / 3700 (5.0) 1450 / 2850 2850 / 2920 Throwaway Throwaway Downflow—mm (4)508x508x50 (8)20x20x2 (4)20x16x2 Downflow (4)508x635x50 (8)508x508x50 Motor W (HP) (Standard/Oversized) Motor RPM (Standard/Oversized) Filters Type Furnished Number Size Recommended Downflow—in Horizontal—mm Horizontal—in (4)20x20x2 (4)20x25x2 (4)508x406x50 (8)508x635x50 (12)508x508x50 (8)20x25x2 (12)20x20x2 6.6 / 6.4 (14.5 / 14.2) 9.0 / 8.2 (19.75 / 18) Refrigerant Charge R-410A kg (lb)(d) (a) Cooling Performance is rated at 35°C (95°F) ambient, 26.7°C (80°F) entering dry bulb, 19.4°C (67°F) entering wet bulb. Heating Performance is rated at 20°C (68°F) ambient, 8.3°C (47°F) entering dry bulb, 6.1°C (43°F) entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal airflow. Rated in accordance with ARI Standard 210/240 or 340/360. (b) EER is rated at ARI conditions and in accordance with DOE test procedures. (c) Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (d) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. RT-PRC034-EN 29 Performance Data Table 4. Gross cooling capacities T/YS*155FD (SI) Ambient Temperature (°C) 30 Enter 16 Airflow DB m3/h (°C) TGC SHC 7140 7820 8500 9180 35 40 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 42.3 34.8 46.1 25.1 51.3 17.9 38.7 32.6 42.6 23.7 47.7 16.7 34.7 30.2 38.6 22.0 43.8 15.3 27 44.2 41.1 47.1 33.6 51.3 20.4 41.0 38.8 43.9 32.1 48.1 19.6 37.4 36.3 40.3 30.2 44.5 18.5 27.7 30 46.3 46.3 48.2 41.0 51.4 29.9 43.4 43.4 45.4 39.3 48.6 28.9 40.1 40.1 42.1 37.3 45.3 33 48.5 48.5 49.4 47.2 51.7 38.3 45.9 45.9 46.9 45.4 49.2 37.2 43.0 43.0 44.0 43.3 46.3 35.8 24 43.5 36.1 47.0 26.4 51.9 18.2 39.9 34.0 43.5 25.0 48.4 16.9 35.9 31.6 39.6 23.3 44.5 15.6 19.8 27 45.5 42.6 48.1 35.0 52.0 21.7 42.3 40.3 44.9 33.5 48.9 20.9 38.7 37.8 41.3 31.6 45.3 30 47.7 47.7 49.3 42.4 52.2 31.3 44.8 44.8 46.5 40.8 49.4 30.3 41.5 41.5 43.2 38.8 46.2 29.1 33 49.9 49.9 50.6 48.7 52.6 39.7 47.4 47.4 48.1 46.9 50.1 38.6 44.7 44.5 45.2 44.8 47.2 37.2 24 44.5 37.4 47.8 27.6 52.4 18.3 41.0 35.3 44.3 26.2 48.9 17.1 37.0 32.9 40.4 24.5 45.0 15.8 27 46.6 43.9 49.0 36.3 52.6 22.9 43.4 41.7 45.8 34.7 49.4 22.1 39.8 39.1 42.2 32.9 45.9 21.0 30 48.9 48.9 50.2 43.8 52.9 32.5 46.0 46.0 47.4 42.1 50.1 31.6 42.7 42.7 44.2 40.1 46.9 30.3 33 51.2 51.2 51.6 50.1 53.3 41.0 48.7 48.7 49.1 48.3 50.8 40.0 46.2 46.2 46.2 46.2 48.0 38.6 24 45.4 38.6 48.4 28.7 52.7 18.4 41.8 36.4 44.9 27.3 49.2 17.2 37.9 34.0 41.0 25.6 45.4 15.9 27 47.6 45.2 49.7 37.4 53.0 24.0 44.4 42.9 46.5 35.9 49.9 23.1 40.8 40.4 42.9 34.1 46.3 22.0 30 49.9 49.9 51.0 45.0 53.4 33.7 47.1 47.1 48.2 43.4 50.6 32.7 43.8 43.8 45.0 41.4 47.4 31.5 33 52.3 52.3 52.4 51.5 53.9 42.3 49.5 49.5 50.0 49.7 51.4 41.2 47.1 47.1 47.1 47.1 48.6 39.8 Ambient Temperature (°C) 45 Enter 16 Airflow DB m3/h (°C) TGC SHC 7140 7820 8500 9180 49 52 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 30.3 27.5 34.3 20.0 39.5 13.8 28.0 26.0 31.9 18.9 37.1 13.0 25.5 24.5 29.5 17.7 34.7 12.1 27 33.3 33.3 36.3 28.1 40.5 17.1 31.1 31.1 34.1 26.9 38.4 16.2 28.9 28.9 31.8 25.7 36.1 15.3 24.3 30 36.4 36.4 38.4 35.1 41.7 26.1 34.4 34.4 36.4 33.8 39.7 25.3 32.3 32.3 34.3 32.5 37.6 33 40.6 40.6 40.6 40.6 43.0 34.1 38.8 38.8 38.8 38.8 41.1 33.1 36.9 36.9 36.9 36.9 39.2 32.1 24 31.6 28.9 35.2 21.3 40.2 14.1 29.2 27.4 32.9 20.2 37.8 13.2 26.8 25.9 30.5 19.0 35.4 12.4 16.6 27 34.6 34.6 37.3 29.5 41.3 18.4 32.5 32.5 35.2 28.3 39.2 17.5 30.2 30.2 32.9 27.1 36.9 30 37.8 37.8 39.6 36.5 42.6 27.5 35.8 35.8 37.6 35.3 40.6 26.6 33.7 33.7 35.5 34.0 38.5 25.7 33 41.9 41.9 41.9 41.9 43.9 35.5 40.0 40.0 40.0 40.0 42.1 34.6 38.1 38.1 38.1 38.1 40.2 33.6 24 32.6 30.2 36.0 22.5 40.7 14.2 30.3 28.7 33.7 21.4 38.4 13.4 27.9 27.2 31.3 20.2 36.0 12.6 27 35.8 35.8 38.2 30.8 41.9 19.6 33.6 33.6 36.1 29.6 39.8 18.7 31.4 31.4 33.8 28.4 37.5 17.8 30 39.1 39.1 40.5 37.9 43.3 28.8 37.1 37.1 38.5 36.7 41.3 27.9 35.0 35.0 36.5 35.3 39.2 27.0 33 42.9 42.9 42.9 42.9 44.7 36.9 41.1 41.1 41.1 41.1 42.9 36.0 39.2 39.2 39.2 39.2 41.0 34.9 24 33.6 31.3 36.7 23.6 41.1 14.4 31.2 29.9 34.4 22.5 38.8 13.6 28.8 28.3 31.9 21.3 36.4 12.7 27 36.8 36.8 39.0 32.0 42.4 20.6 34.7 34.7 36.8 30.8 40.3 19.8 32.4 32.4 34.6 29.5 38.0 18.9 30 40.2 40.2 41.3 39.2 43.8 30.0 38.2 38.2 39.4 37.9 41.8 29.1 36.1 36.1 37.3 36.6 39.8 28.2 33 43.8 43.8 43.8 43.8 45.3 38.2 42.0 42.0 42.0 42.0 43.5 37.2 40.1 40.1 40.1 40.1 41.6 36.2 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) 30 RT-PRC034-EN Performance Data Gross Cooling Capacities Table 5. Gross cooling capacities T/YS*155FD (IP) Ambient Temperature (°F) 85 Enter 61 Airflow DB CFM (°F) TGC SHC 75 4200 4600 5000 5400 5800 95 105 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 144.2 118.6 157.4 85.8 174.9 61.2 132.1 111.3 145.3 81.0 162.9 57.0 118.5 103.0 131.8 75.1 149.4 52.3 80 151.0 140.2 160.8 114.7 175.0 69.7 139.9 132.5 149.9 109.5 164.2 66.9 127.5 123.8 137.5 103.2 151.9 63.0 85 158.0 158.0 164.5 139.8 175.4 102.1 148.2 148.2 154.8 134.1 165.8 98.8 136.9 136.9 143.6 127.3 154.7 94.5 90 165.4 165.4 168.6 161.0 176.2 130.5 156.7 156.7 160.1 154.8 167.8 126.8 146.6 146.6 150.1 147.6 157.9 122.0 75 148.3 123.2 160.5 90.2 177.1 62.0 136.2 116.0 148.5 85.4 165.1 57.8 122.6 107.8 135.0 79.6 151.8 53.1 80 155.3 145.2 164.2 119.4 177.5 74.1 144.3 137.5 153.4 114.1 166.7 71.3 132.0 128.8 141.1 107.9 154.5 67.4 85 162.6 162.6 168.2 144.7 178.2 106.7 152.8 152.8 158.6 139.0 168.6 103.4 141.6 141.6 147.5 132.3 157.6 99.2 90 170.3 170.3 172.6 166.2 179.3 135.4 161.7 161.7 164.1 160.0 170.9 131.7 152.6 151.7 154.2 152.9 161.0 127.0 75 151.8 127.6 163.1 94.2 178.7 62.6 139.8 120.4 151.1 89.4 166.8 58.4 126.3 112.1 137.7 83.6 153.5 53.7 80 159.1 149.8 167.1 123.7 179.4 78.1 148.2 142.1 156.3 118.5 168.7 75.3 135.9 133.5 144.1 112.2 156.6 71.5 85 166.7 166.7 171.4 149.3 180.4 111.0 157.0 157.0 161.8 143.7 170.9 107.8 145.8 145.8 150.7 137.0 159.9 103.5 90 174.6 174.6 176.0 171.1 181.8 140.0 166.1 166.1 167.6 165.0 173.4 136.3 157.7 157.7 157.7 157.7 163.7 131.6 75 154.8 131.5 165.1 97.9 179.8 62.9 142.8 124.3 153.2 93.1 168.0 58.8 129.4 116.1 139.9 87.3 154.8 54.2 80 162.3 154.1 169.4 127.7 180.8 81.7 151.5 146.4 158.7 122.5 170.2 79.0 139.3 137.8 146.5 116.2 158.1 75.2 85 170.2 170.2 174.0 153.6 182.1 115.0 160.6 160.6 164.4 147.9 172.6 111.7 149.5 149.5 153.4 141.3 161.7 107.5 90 178.4 178.4 178.9 175.6 183.8 144.3 168.8 168.8 170.5 169.5 175.4 140.6 160.7 160.7 160.7 160.7 165.7 135.9 75 157.2 135.2 166.6 101.2 180.4 63.1 145.2 128.0 154.8 96.4 168.6 59.0 131.9 119.8 141.5 90.7 155.4 54.4 80 165.0 158.0 171.2 131.3 181.7 85.1 154.3 150.3 160.5 126.1 171.1 82.3 142.1 141.7 148.4 119.9 159.0 78.6 85 173.2 173.2 176.0 157.5 183.2 118.5 163.6 163.6 166.5 151.8 173.8 115.3 152.6 152.6 155.6 145.2 163.0 111.1 90 179.5 179.5 181.3 179.8 185.2 148.2 172.9 172.9 172.9 172.9 176.9 144.5 163.2 163.2 163.2 163.2 167.3 139.8 Ambient Temperature (°F) 115 Enter 61 Airflow DB CFM (°F) TGC SHC 4200 4600 5000 5400 5800 120 125 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC 61 67 SHC TGC 61 67 SHC SHC TGC SHC 75 103.5 93.8 116.9 68.3 134.6 47.1 95.4 88.8 108.9 64.5 126.7 44.3 87.0 83.5 100.5 60.5 118.4 41.4 80 113.7 113.7 123.8 95.9 138.3 58.2 106.2 106.2 116.4 91.9 130.9 55.4 98.4 98.4 108.6 87.6 123.2 52.3 85 124.2 124.2 131.1 119.6 142.2 89.2 117.4 117.4 124.3 115.4 135.5 86.2 110.2 110.2 117.1 110.9 128.3 82.9 90 138.7 138.7 138.7 138.7 146.5 116.3 132.4 132.4 132.4 132.4 140.4 113.0 125.9 125.9 125.9 125.9 133.8 109.5 93.5 112.2 69.0 129.1 45.2 91.3 TGC SHC 73 TGC 99.7 TGC 73 SHC TGC SHC 75 107.7 98.5 120.2 72.7 137.0 47.9 80 118.2 118.2 127.4 100.6 140.9 62.6 110.8 110.8 120.0 96.6 133.6 59.8 103.0 103.0 112.3 92.4 125.9 56.8 88.3 103.9 64.9 120.8 42.3 85 129.1 129.1 134.9 124.6 145.2 93.9 122.2 122.2 128.2 120.4 138.4 90.9 115.0 115.0 121.0 115.9 131.4 87.6 90 142.8 142.8 142.8 142.8 149.8 121.3 136.6 136.6 136.6 136.6 143.6 118.0 130.1 130.1 130.1 130.1 137.1 114.6 75 111.4 102.9 122.9 76.8 138.8 48.6 103.4 97.9 115.0 73.1 130.9 45.8 80 122.2 122.2 130.4 105.0 143.0 66.7 114.8 114.8 123.1 101.0 135.7 63.9 107.1 107.1 115.4 96.8 128.1 60.9 95.1 92.7 106.7 69.0 122.7 42.9 85 133.3 133.3 138.3 129.3 147.6 98.3 126.5 126.5 131.5 125.1 140.9 95.3 119.4 119.4 124.4 120.6 133.8 92.0 90 146.4 146.4 146.4 146.4 152.5 125.9 140.3 140.3 140.3 140.3 146.3 122.7 133.8 133.8 133.8 133.8 139.9 119.2 75 114.5 106.9 125.1 80.6 140.1 49.0 106.6 102.0 117.2 76.8 132.3 46.3 80 125.6 125.6 132.9 109.0 144.6 70.4 118.2 118.2 125.6 105.0 137.3 67.7 110.5 110.5 118.0 100.8 129.7 64.6 98.3 96.7 109.0 72.8 124.1 43.4 85 137.0 137.0 141.0 133.6 149.4 102.3 130.2 130.2 134.3 129.4 142.8 99.3 123.1 123.1 127.2 124.9 135.7 96.0 90 149.5 149.5 149.5 149.5 154.6 130.2 143.4 143.4 143.4 143.4 148.5 127.0 136.9 136.9 136.9 136.9 142.1 123.6 75 117.1 110.6 126.8 84.0 140.8 49.3 109.2 105.6 118.9 80.2 133.0 46.6 100.9 100.4 110.7 76.2 124.8 43.7 80 128.5 128.5 134.9 112.7 145.6 73.8 121.1 121.1 127.6 108.7 138.4 71.0 113.5 113.5 120.0 104.5 130.8 68.0 85 140.2 140.2 143.3 137.6 150.7 105.9 133.4 133.4 136.6 133.4 144.1 103.0 128.2 128.2 129.5 128.9 137.1 99.7 90 152.0 152.0 152.0 152.0 156.2 134.2 145.9 145.9 145.9 145.9 150.1 131.0 139.4 139.4 139.4 139.4 143.7 127.5 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) RT-PRC034-EN 31 Performance Data Gross Cooling Capacities Table 6. Gross cooling capacities T/YS*175FD (SI) Ambient Temperature (°C) 30 Enter 16 Airflow DB m3/h (°C) TGC SHC 7985 8750 9515 10280 11045 35 40 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 46.9 39.4 52.1 29.4 59.4 20.8 42.1 36.6 47.2 27.5 54.5 19.1 36.7 33.4 41.8 25.2 49.0 17.1 27 49.2 46.4 53.1 38.6 59.1 24.9 45.1 43.8 49.0 36.8 54.9 24.0 40.4 40.4 44.2 34.5 50.1 22.7 30 51.8 51.8 54.3 46.4 59.0 34.9 48.4 48.4 50.9 44.8 55.5 34.1 44.4 44.4 46.9 42.6 51.4 32.8 33 54.5 54.5 55.7 53.0 59.0 43.6 51.8 51.8 53.0 51.4 56.3 42.9 49.2 48.6 49.7 49.3 52.9 41.7 24 48.2 40.9 53.2 30.9 60.3 21.1 43.4 38.1 48.3 29.0 55.4 19.4 38.0 34.9 42.9 26.7 49.9 17.5 27 50.6 48.0 54.2 40.1 60.0 26.4 46.5 45.3 50.1 38.3 55.8 25.5 41.8 41.8 45.4 36.1 51.1 24.2 30 53.1 53.1 55.5 48.0 59.9 36.4 49.8 49.8 52.1 46.3 56.5 35.7 45.8 45.8 48.1 44.2 52.4 34.4 33 55.9 55.9 57.0 54.7 60.1 45.2 53.3 53.3 54.3 53.1 57.3 44.5 50.5 50.5 51.0 51.0 54.0 43.3 24 49.4 42.4 54.2 32.4 61.1 21.4 44.6 39.6 49.4 30.5 56.2 19.7 39.3 36.3 44.0 28.1 50.8 17.8 27 51.8 49.5 55.3 41.6 60.9 27.9 47.8 46.8 51.2 39.9 56.7 27.1 43.1 43.1 46.5 37.6 52.0 25.7 30 54.4 54.4 56.6 49.6 60.8 38.0 51.1 51.1 53.2 47.9 57.4 37.2 47.2 47.2 49.3 45.7 53.4 35.9 33 57.3 57.3 58.1 56.3 61.0 46.8 54.7 54.7 55.5 54.7 58.3 46.1 52.2 52.2 52.2 52.2 55.0 44.9 24 50.5 43.8 55.1 33.8 61.8 21.6 45.8 41.1 50.3 32.0 57.0 19.9 40.4 37.8 45.0 29.6 51.5 18.0 27 52.9 51.0 56.2 43.1 61.6 29.4 49.0 48.4 52.2 41.4 57.5 28.6 44.4 44.4 47.6 39.1 52.8 27.2 30 55.6 55.6 57.6 51.2 61.7 39.6 52.4 52.4 54.3 49.5 58.3 38.8 48.5 48.5 50.4 47.3 54.3 37.5 33 58.5 58.5 59.2 57.9 61.9 48.4 56.0 56.0 56.6 56.3 59.2 47.7 53.4 53.4 53.4 53.4 56.0 46.5 24 51.5 45.3 55.9 35.3 62.4 21.8 46.8 42.5 51.2 33.4 57.6 20.2 41.5 39.2 45.9 31.0 52.2 18.3 27 54.0 52.5 57.1 44.6 62.3 30.9 50.1 49.9 53.1 42.8 58.2 30.0 45.5 45.5 48.5 40.6 53.6 28.6 30 56.8 56.8 58.5 52.7 62.4 41.1 53.5 53.5 55.3 51.0 59.0 40.3 49.7 49.7 51.4 48.8 55.1 39.0 33 59.7 59.7 60.2 59.5 62.7 50.0 57.6 57.6 57.6 57.6 60.1 49.3 54.4 54.4 54.4 54.4 56.8 48.1 Ambient Temperature (°C) 45 Enter 16 Airflow DB m3/h (°C) TGC SHC 7985 8750 9515 10280 11045 49 52 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 30.7 29.6 35.7 22.4 42.8 15.0 27.5 27.5 32.5 20.7 39.6 13.8 24.1 24.1 29.1 19.0 36.1 12.6 27 35.2 35.2 38.9 31.8 44.7 20.8 32.3 32.3 36.0 30.2 41.8 19.7 29.3 29.3 32.9 28.5 38.7 18.4 30 39.8 39.8 42.2 39.9 46.7 31.0 37.3 37.3 39.7 38.4 44.1 29.9 36.6 34.7 37.0 36.7 41.4 28.7 33 45.8 45.8 45.8 45.8 48.9 40.0 43.6 43.6 43.6 43.6 46.7 38.9 41.3 41.3 41.3 41.3 44.4 37.8 24 32.1 31.1 36.9 23.8 43.8 15.3 28.8 28.8 33.7 22.2 40.6 14.2 25.5 25.5 30.3 20.5 37.1 13.0 27 36.6 36.6 40.1 33.3 45.7 22.3 33.7 33.7 37.2 31.7 42.8 21.2 30.7 30.7 34.2 30.0 39.8 19.9 30 41.3 41.3 43.5 41.5 47.8 32.6 38.8 38.8 41.0 39.9 45.2 31.5 38.0 38.0 38.3 38.3 42.6 30.3 33 47.1 47.1 47.1 47.1 50.1 41.6 45.0 45.0 45.0 45.0 47.9 40.5 42.7 42.7 42.7 42.7 45.6 39.4 24 33.3 32.6 38.0 25.3 44.7 15.7 30.2 30.2 34.8 23.6 41.5 14.5 26.8 26.8 31.4 21.9 38.1 13.3 27 37.9 37.9 41.3 34.8 46.7 23.8 35.1 35.1 38.4 33.2 43.8 22.7 32.1 32.1 35.4 31.5 40.7 21.4 30 42.7 42.7 44.7 43.0 48.8 34.1 40.2 40.2 42.2 41.5 46.3 33.1 39.6 39.6 39.6 39.6 43.6 31.8 33 48.4 48.4 48.4 48.4 51.1 43.2 46.2 46.2 46.2 46.2 49.0 42.1 44.0 44.0 44.0 44.0 46.7 41.0 24 34.6 34.0 39.0 26.7 45.5 15.9 31.4 31.4 35.8 25.1 42.3 14.8 28.1 28.1 32.5 23.3 38.9 13.6 27 39.2 39.2 42.3 36.3 47.5 25.3 36.4 36.4 39.5 34.7 44.7 24.2 33.4 33.4 36.5 33.0 41.6 22.9 30 44.0 44.0 45.8 44.6 49.7 35.7 42.9 41.6 43.4 43.0 47.2 34.6 40.7 40.7 40.7 40.7 44.6 33.4 33 49.6 49.6 49.6 49.6 52.1 44.8 47.4 47.4 47.4 47.4 50.0 43.7 45.2 45.2 45.2 45.2 47.7 42.6 24 35.7 35.4 39.9 28.1 46.3 16.2 32.5 32.5 36.8 26.5 43.1 15.1 29.2 29.2 33.4 24.7 39.7 13.9 27 40.4 40.4 43.3 37.8 48.3 26.8 37.6 37.6 40.5 36.2 45.5 25.6 34.6 34.6 37.5 34.4 42.5 24.4 30 45.3 45.3 46.9 46.1 50.6 37.2 44.4 44.4 44.4 44.4 48.1 36.1 41.8 41.8 41.8 41.8 45.4 34.9 33 50.7 50.7 50.7 50.7 53.0 46.4 48.5 48.5 48.5 48.5 50.9 45.3 46.3 46.3 46.3 46.3 48.6 44.1 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) 32 RT-PRC034-EN Performance Data Gross Cooling Capacities Table 7. Gross cooling capacities T/YS*175FD (IP) Ambient Temperature (°F) 85 Enter 61 Airflow DB CFM (°F) TGC SHC 75 4700 5150 5600 6050 6500 95 105 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 160.0 134.4 177.8 100.3 202.7 70.9 143.6 125.0 161.2 94.0 185.9 65.1 125.1 113.9 142.5 86.0 167.0 58.5 80 168.0 158.5 181.2 131.5 201.6 84.8 154.0 149.4 167.1 125.6 187.2 81.9 138.0 138.0 150.9 117.8 170.8 77.3 85 176.6 176.6 185.3 158.4 201.2 118.9 165.0 165.0 173.6 152.7 189.3 116.3 151.5 151.5 159.9 145.3 175.3 111.9 90 185.9 185.9 190.1 180.9 201.4 148.6 176.8 176.8 180.8 175.5 192.0 146.3 167.8 165.7 169.5 168.3 180.5 142.2 75 164.3 139.5 181.4 105.3 205.6 72.0 148.0 130.1 165.0 99.0 189.0 66.1 129.7 119.0 146.4 91.0 170.2 59.6 80 172.5 163.7 185.1 136.8 204.7 90.1 158.6 154.6 171.0 130.8 190.5 87.1 142.7 142.7 154.9 123.0 174.2 82.5 85 181.3 181.3 189.4 163.9 204.5 124.3 169.9 169.9 177.8 158.1 192.7 121.7 156.4 156.4 164.1 150.6 178.9 117.3 90 190.7 190.7 194.3 186.5 205.0 154.2 181.8 181.8 185.2 181.1 195.6 151.8 172.2 172.2 174.0 173.9 184.3 147.7 75 168.4 144.5 184.8 110.4 208.3 72.9 152.2 135.1 168.4 104.1 191.8 67.1 134.0 124.0 150.1 96.0 173.2 60.6 80 176.7 169.0 188.6 142.0 207.6 95.2 163.0 159.8 174.7 136.0 193.5 92.3 147.2 147.2 158.7 128.2 177.4 87.6 85 185.7 185.7 193.1 169.2 207.6 129.7 174.4 174.4 181.6 163.5 195.9 127.0 161.1 161.1 168.1 156.0 182.2 122.6 90 195.3 195.3 198.2 192.1 208.2 159.7 186.5 186.5 189.2 186.6 199.0 157.3 178.2 178.2 178.2 178.2 187.8 153.2 75 172.1 149.5 187.9 115.4 210.7 73.8 156.1 140.1 171.7 109.0 194.3 68.0 138.0 128.9 153.4 100.9 175.8 61.5 80 180.6 174.2 191.9 147.2 210.2 100.4 167.0 165.0 178.1 141.1 196.2 97.4 151.4 151.4 162.3 133.3 180.2 92.7 85 189.8 189.8 196.6 174.6 210.4 135.0 178.7 178.7 185.2 168.8 198.8 132.3 165.5 165.5 171.8 161.3 185.3 127.9 90 199.7 199.7 201.9 197.6 211.2 165.2 191.1 191.1 193.0 192.1 202.1 162.8 182.0 182.0 182.0 182.0 191.0 158.7 75 175.6 154.5 190.7 120.3 212.9 74.5 159.7 145.0 174.6 113.9 196.6 68.8 141.7 133.8 156.4 105.8 178.2 62.4 80 184.3 179.3 194.9 152.3 212.5 105.5 170.8 170.1 181.2 146.2 198.7 102.5 155.3 155.3 165.5 138.4 182.8 97.7 85 193.7 193.7 199.7 179.9 212.9 140.3 182.6 182.6 188.5 174.1 201.5 137.5 169.6 169.6 175.2 166.5 188.0 133.1 90 203.7 203.7 205.3 203.1 213.9 170.7 196.5 196.5 196.5 196.5 204.9 168.2 185.7 185.7 185.7 185.7 193.9 164.1 Ambient Temperature (°F) 115 Enter 61 Airflow DB CFM (°F) TGC SHC 4700 5150 5600 6050 6500 120 125 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC 61 67 SHC TGC 61 67 73 TGC SHC SHC TGC SHC TGC SHC 75 104.7 101.1 121.9 76.3 146.2 51.2 93.7 93.7 110.8 70.8 135.0 47.2 82.2 82.2 99.2 64.8 123.3 43.1 80 120.0 120.0 132.6 108.4 152.4 70.9 110.2 110.2 122.8 103.0 142.5 67.1 99.9 99.9 112.4 97.2 132.0 62.9 85 135.9 135.9 144.1 136.1 159.3 105.9 127.3 127.3 135.4 130.9 150.6 102.2 125.0 118.3 126.3 125.2 141.4 98.1 90 156.2 156.2 156.2 156.2 166.9 136.4 148.8 148.8 148.8 148.8 159.4 132.8 140.8 140.8 140.8 140.8 151.4 128.9 98.4 TGC 73 SHC 98.4 114.9 75.7 138.4 48.4 87.0 TGC SHC 75 109.4 106.1 125.9 81.3 149.5 52.3 80 124.8 124.8 136.8 113.6 156.0 76.1 115.1 115.1 127.0 108.2 146.0 72.3 104.9 104.9 116.7 102.4 135.6 68.0 87.0 103.3 69.8 126.7 44.4 85 141.0 141.0 148.5 141.4 163.1 111.2 132.5 132.5 139.9 136.2 154.4 107.5 129.5 129.5 130.8 130.5 145.2 103.4 90 160.8 160.8 160.8 160.8 170.9 141.9 153.4 153.4 153.4 153.4 163.4 138.3 145.5 145.5 145.5 145.5 155.4 134.4 75 113.8 111.1 129.6 86.2 152.6 53.4 102.9 102.9 118.7 80.7 141.5 49.5 80 129.4 129.4 140.8 118.7 159.2 81.2 119.8 119.8 131.0 113.3 149.4 77.4 109.6 109.6 120.8 107.5 139.0 73.1 91.5 91.5 107.2 74.7 129.9 45.5 85 145.7 145.7 152.6 146.8 166.5 116.5 137.3 137.3 144.1 141.5 157.9 112.8 135.0 135.0 135.0 135.0 148.8 108.6 90 165.1 165.1 165.1 165.1 174.5 147.4 157.8 157.8 157.8 157.8 167.1 143.8 150.0 150.0 150.0 150.0 159.2 139.8 75 117.9 116.0 133.1 91.1 155.3 54.4 107.1 107.1 122.2 85.6 144.3 50.5 80 133.7 133.7 144.4 123.8 162.2 86.3 124.1 124.1 134.7 118.4 152.4 82.4 114.0 114.0 124.5 112.5 142.1 78.1 95.8 95.8 110.7 79.6 132.8 46.5 85 150.2 150.2 156.4 152.0 169.7 121.7 146.5 141.9 147.9 146.7 161.1 118.0 139.0 139.0 139.0 139.0 152.0 113.9 90 169.1 169.1 169.1 169.1 177.8 152.8 161.8 161.8 161.8 161.8 170.5 149.2 154.1 154.1 154.1 154.1 162.6 145.2 75 121.7 120.9 136.3 96.0 157.8 55.2 111.0 111.0 125.4 90.4 146.9 51.4 80 137.8 137.8 147.8 128.8 164.9 91.3 128.2 128.2 138.1 123.4 155.1 87.4 118.2 118.2 128.0 117.5 144.9 83.1 99.7 99.7 114.0 84.4 135.4 47.4 85 154.5 154.5 160.0 157.2 172.5 126.9 151.6 151.6 151.6 151.6 164.0 123.2 142.6 142.6 142.6 142.6 155.0 119.0 90 172.8 172.8 172.8 172.8 180.9 158.2 165.6 165.6 165.6 165.6 173.6 154.6 157.9 157.9 157.9 157.9 165.8 150.5 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) RT-PRC034-EN 33 Performance Data Gross Cooling Capacities Table 8. Gross cooling capacities T/YS*200FD (SI) Ambient Temperature (°C) 30 Enter 16 Airflow DB m3/h (°C) TGC SHC 9005 9940 10875 11810 12745 35 40 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 57.5 47.4 63.3 35.1 71.6 25.1 52.6 44.6 58.4 33.3 66.6 23.3 47.6 41.6 53.2 31.2 61.3 21.5 27 60.1 55.6 64.7 46.1 71.7 29.7 55.9 52.8 60.3 44.2 67.2 28.8 51.3 49.7 55.7 42.0 62.5 27.6 30 62.7 62.1 65.9 55.3 71.6 41.7 58.9 58.9 62.1 53.4 67.7 40.7 55.0 55.0 58.0 51.2 63.5 39.5 33 65.1 65.1 67.1 62.9 71.4 52.0 61.9 61.9 63.8 60.9 68.0 51.0 58.5 58.5 60.2 58.7 64.4 49.7 24 59.7 49.7 65.2 37.1 73.1 25.6 54.8 46.9 60.2 35.3 68.1 23.8 49.7 43.9 55.0 33.2 62.8 22.0 27 62.4 58.0 66.6 48.2 73.2 31.5 58.0 55.2 62.1 46.3 68.7 30.6 53.5 52.1 57.5 44.1 64.0 29.4 30 64.9 64.6 67.8 57.5 73.2 43.6 61.1 61.1 63.9 55.6 69.2 42.6 57.1 57.1 59.8 53.4 65.0 41.4 33 67.4 67.4 69.0 65.2 73.0 54.0 64.1 64.1 65.6 63.3 69.6 53.0 60.6 60.6 62.1 61.1 65.9 51.8 24 61.5 51.6 66.7 38.7 74.3 26.0 56.6 48.8 61.7 36.9 69.2 24.2 51.5 45.8 56.5 34.8 63.9 22.4 27 64.2 60.1 68.1 49.9 74.4 33.0 59.8 57.2 63.6 48.0 69.8 32.0 55.3 54.2 58.9 45.9 65.1 30.9 30 66.8 66.8 69.3 59.4 74.3 45.2 63.0 63.0 65.4 57.5 70.3 44.2 58.9 58.9 61.3 55.3 66.1 43.0 33 69.2 69.2 70.5 67.2 74.2 55.8 66.0 66.0 67.1 65.3 70.7 54.7 62.9 62.5 63.5 63.1 67.1 53.5 24 63.0 53.2 67.8 40.0 75.0 26.3 58.1 50.4 62.8 38.2 69.9 24.5 52.9 47.4 57.5 36.1 64.6 22.6 27 65.7 61.7 69.2 51.3 75.2 34.1 61.3 58.9 64.7 49.4 70.6 33.1 56.7 55.9 60.0 47.3 65.8 32.0 30 68.3 68.3 70.5 60.9 75.2 46.4 64.4 64.4 66.6 59.0 71.1 45.5 60.4 60.4 62.4 56.9 66.9 44.2 33 70.8 70.8 71.7 68.9 75.0 57.1 67.4 67.4 68.3 66.9 71.5 56.1 64.6 64.6 64.6 64.6 67.8 54.8 24 64.1 54.4 68.6 40.9 75.5 26.4 59.1 51.6 63.5 39.1 70.3 24.6 53.9 48.6 58.2 37.0 64.9 22.7 27 66.8 63.1 70.0 52.4 75.6 34.8 62.4 60.3 65.5 50.5 71.0 33.9 57.7 57.2 60.7 48.4 66.2 32.7 30 69.4 69.4 71.3 62.1 75.6 47.3 65.5 65.5 67.3 60.2 71.5 46.4 61.4 61.4 63.1 58.0 67.3 45.1 33 71.9 71.9 72.5 70.2 75.5 58.1 68.6 68.6 69.1 68.2 72.0 57.1 65.4 65.4 65.4 65.4 68.2 55.9 Ambient Temperature (°C) 45 Enter 16 Airflow DB m3/h (°C) TGC SHC 9005 9940 10875 11810 12745 49 52 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 42.3 38.3 47.9 28.8 55.9 19.6 39.5 36.6 45.1 27.6 53.0 18.6 36.7 34.8 42.2 26.2 NA NA 27 46.6 46.4 50.8 39.7 57.6 26.1 44.1 44.1 48.3 38.4 55.0 25.3 41.6 41.6 45.8 37.0 NA NA 30 50.7 50.7 53.7 48.8 59.1 38.0 48.5 48.5 51.5 47.5 56.8 37.2 46.3 46.3 49.2 46.1 NA NA 33 55.9 55.9 56.5 56.2 60.6 48.2 54.5 54.5 54.5 54.5 58.6 47.3 52.5 52.5 52.5 52.5 NA NA 24 44.4 40.6 49.6 30.8 57.3 20.0 41.6 38.8 46.8 29.6 54.4 19.1 38.8 37.0 43.9 28.2 NA NA 27 48.7 48.7 52.6 41.8 59.0 27.9 46.2 46.2 50.1 40.5 56.4 27.1 43.6 43.6 47.5 39.1 NA NA 30 52.9 52.9 55.5 51.0 60.6 39.9 50.6 50.6 53.2 49.7 58.3 39.1 48.4 48.4 50.9 48.4 NA NA 33 58.3 58.3 58.3 58.3 62.0 50.3 56.3 56.3 56.3 56.3 60.0 49.4 54.2 54.2 54.2 54.2 NA NA 24 46.1 42.5 51.0 32.5 58.3 20.4 43.3 40.8 48.2 31.2 55.5 19.4 40.5 39.0 45.3 29.9 NA NA 27 50.4 50.4 54.0 43.5 60.0 29.4 47.9 47.9 51.5 42.3 57.5 28.6 45.4 45.4 48.9 40.9 NA NA 30 54.6 54.6 56.9 52.9 61.6 41.5 52.4 52.4 54.6 51.6 59.3 40.7 50.1 50.1 52.3 50.3 NA NA 33 59.7 59.7 59.7 59.7 63.1 52.0 57.7 57.7 57.7 57.7 61.1 51.1 55.6 55.6 55.6 55.6 NA NA 24 47.5 44.1 52.0 33.7 59.0 20.7 44.7 42.4 49.2 32.5 56.1 19.6 41.8 40.6 46.3 31.2 NA NA 27 51.8 51.8 55.1 44.9 60.7 30.5 49.3 49.3 52.5 43.7 58.1 29.7 46.7 46.7 49.9 42.3 NA NA 30 56.0 56.0 58.0 54.5 62.4 42.8 53.8 53.8 55.7 53.2 60.0 42.0 51.5 51.5 53.3 51.8 NA NA 33 60.8 60.8 60.8 60.8 63.9 53.3 58.7 58.7 58.7 58.7 61.8 52.5 56.7 56.7 56.7 56.7 NA NA 24 48.5 45.3 52.7 34.7 59.3 20.8 45.7 43.6 49.8 33.4 56.4 19.8 42.8 41.8 46.9 32.1 NA NA 27 52.8 52.8 55.7 46.0 61.1 31.3 50.3 50.3 53.2 44.7 58.5 30.5 47.7 47.7 50.5 43.4 NA NA 30 57.1 57.1 58.7 55.6 62.7 43.7 54.8 54.8 56.4 54.3 60.4 42.8 52.5 52.5 54.0 53.0 NA NA 33 61.5 61.5 61.5 61.5 64.2 54.4 59.4 59.4 59.4 59.4 62.1 53.5 NA NA NA NA NA NA Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) 34 RT-PRC034-EN Performance Data Gross Cooling Capacities Table 9. Gross cooling capacities T/YS*200FD (IP) Ambient Temperature (°F) 85 Enter 61 Airflow DB CFM (°F) TGC SHC 75 5300 5850 6400 6950 7500 95 105 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 61 TGC 67 SHC TGC 73 SHC TGC SHC 196.1 161.7 216.0 119.8 244.3 85.5 179.6 152.2 199.2 113.5 227.2 79.5 162.3 141.9 181.7 106.4 209.3 73.3 80 205.2 189.7 220.7 157.1 244.5 101.4 190.6 180.1 205.7 150.7 229.3 98.1 175.1 169.6 190.0 143.4 213.2 94.1 85 213.9 211.9 224.9 188.7 244.3 142.3 201.1 201.1 211.8 182.1 230.9 138.9 187.5 187.5 197.9 174.7 216.7 134.7 90 222.1 222.1 228.8 214.5 243.7 177.4 211.2 211.2 217.5 207.8 232.2 173.9 199.4 199.4 205.5 200.3 219.8 169.6 75 203.6 169.5 222.3 126.6 249.4 87.3 187.0 160.0 205.5 120.3 232.2 81.3 169.6 149.6 187.8 113.1 214.2 75.0 80 212.7 197.9 227.1 164.3 249.7 107.5 198.0 188.3 212.0 157.9 234.4 104.3 182.4 177.8 196.2 150.6 218.2 100.3 85 221.5 220.5 231.4 196.3 249.6 148.8 208.6 208.6 218.2 189.7 236.1 145.5 194.9 194.9 204.2 182.4 221.8 141.3 90 229.8 229.8 235.3 222.5 249.0 184.4 218.7 218.7 223.9 215.8 237.4 180.9 206.9 206.9 211.7 208.3 224.9 176.6 75 209.8 176.1 227.4 132.1 253.3 88.7 193.1 166.6 210.4 125.8 236.0 82.6 175.6 156.2 192.6 118.7 217.9 76.3 80 219.0 204.9 232.2 170.3 253.7 112.5 204.2 195.3 217.0 163.9 238.2 109.3 188.5 184.8 201.1 156.6 221.9 105.3 85 227.8 227.8 236.6 202.7 253.6 154.2 214.8 214.8 223.2 196.2 240.0 150.9 201.0 201.0 209.1 188.8 225.6 146.7 90 236.2 236.2 240.5 229.3 253.1 190.2 225.0 225.0 229.0 222.7 241.3 186.8 214.6 213.1 216.8 215.2 228.8 182.5 75 214.9 181.4 231.3 136.5 256.0 89.6 198.1 171.9 214.2 130.2 238.6 83.5 180.4 161.6 196.2 123.1 220.4 77.1 80 224.1 210.7 236.1 175.1 256.4 116.3 209.2 201.1 220.8 168.7 240.8 113.1 193.4 190.6 204.8 161.4 224.4 109.1 85 233.0 233.0 240.5 207.9 256.4 158.4 219.8 219.8 227.1 201.4 242.7 155.1 205.9 205.9 212.9 194.0 228.1 151.0 90 241.4 241.4 244.5 235.0 256.0 194.8 230.1 230.1 232.9 228.3 244.1 191.4 220.6 220.6 220.6 220.6 231.4 187.1 75 218.7 185.6 233.9 139.6 257.5 90.1 201.7 176.1 216.7 133.4 239.9 84.0 184.0 165.8 198.6 126.3 221.6 77.6 80 228.0 215.3 238.8 178.7 257.9 118.9 212.9 205.7 223.4 172.3 242.2 115.7 197.0 195.2 207.2 165.0 225.7 111.7 85 236.9 236.9 243.3 211.9 258.0 161.4 223.6 223.6 229.7 205.4 244.1 158.2 209.6 209.6 215.4 198.0 229.5 154.0 90 245.4 245.4 247.3 239.4 257.6 198.3 234.0 234.0 235.6 232.8 245.6 194.8 223.1 223.1 223.1 223.1 232.8 190.6 Ambient Temperature (°F) 115 Enter 61 Airflow DB CFM (°F) TGC SHC 5300 5850 6400 6950 7500 120 125 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 61 TGC 67 SHC TGC 73 SHC TGC SHC 75 144.3 130.7 163.3 98.4 190.6 66.7 134.9 124.7 153.8 94.0 180.9 63.3 125.4 118.6 144.1 89.5 NA NA 80 158.9 158.3 173.5 135.3 196.4 89.1 150.4 150.4 164.9 130.9 187.6 86.4 141.8 141.8 156.1 126.3 NA NA 85 173.1 173.1 183.2 166.5 201.7 129.7 165.6 165.6 175.6 162.0 193.9 126.8 157.9 157.9 167.7 157.4 NA NA 90 190.7 190.7 192.6 191.9 206.7 164.4 185.9 185.9 185.9 185.9 199.8 161.5 178.9 178.9 178.9 178.9 NA NA 75 151.4 138.4 169.3 105.1 195.4 68.4 142.0 132.5 159.7 100.8 185.7 65.0 132.4 126.4 149.9 96.3 NA NA 80 166.1 166.1 179.5 142.5 201.2 95.3 157.6 157.6 170.9 138.1 192.4 92.6 148.9 148.9 162.0 133.5 NA NA 85 180.3 180.3 189.3 174.1 206.6 136.3 172.8 172.8 181.6 169.7 198.8 133.4 165.0 165.0 173.7 165.0 NA NA 90 198.8 198.8 198.8 198.8 211.6 171.5 192.0 192.0 192.0 192.0 204.7 168.6 185.0 185.0 185.0 185.0 NA NA 75 157.3 145.0 174.0 110.7 199.0 69.6 147.9 139.1 164.4 106.4 189.2 66.2 138.2 133.0 154.6 101.9 NA NA 80 172.0 172.0 184.3 148.5 204.9 100.4 163.5 163.5 175.6 144.2 196.0 97.6 154.8 154.8 166.7 139.6 NA NA 85 186.4 186.4 194.2 180.6 210.3 141.7 178.8 178.8 186.4 176.1 202.4 138.9 170.9 170.9 178.4 171.5 NA NA 90 203.7 203.7 203.7 203.7 215.4 177.3 196.8 196.8 196.8 196.8 208.4 174.4 189.8 189.8 189.8 189.8 NA NA 75 162.0 150.4 177.5 115.1 201.3 70.5 152.5 144.5 167.8 110.8 191.5 67.0 142.8 138.4 158.0 106.3 NA NA 80 176.8 176.8 187.9 153.3 207.3 104.2 168.2 168.2 179.1 149.0 198.4 101.4 159.4 159.4 170.2 144.4 NA NA 85 191.2 191.2 197.8 185.8 212.8 146.0 183.5 183.5 190.0 181.4 204.8 143.1 175.6 175.6 182.0 176.7 NA NA 90 207.3 207.3 207.3 207.3 217.9 182.0 200.4 200.4 200.4 200.4 210.8 179.1 193.3 193.3 193.3 193.3 NA NA 75 165.4 154.6 179.8 118.3 202.4 70.9 155.9 148.7 170.1 114.0 192.6 67.4 146.1 142.6 160.1 109.5 NA NA 80 180.3 180.3 190.2 157.0 208.4 106.8 171.6 171.6 181.4 152.6 199.5 104.0 162.8 162.8 172.4 148.0 NA NA 85 194.7 194.7 200.2 189.8 214.0 149.0 187.0 187.0 192.3 185.4 205.9 146.2 179.0 179.0 184.2 180.8 NA NA 90 209.8 209.8 209.8 209.8 219.1 185.4 202.8 202.8 202.8 202.8 212.0 182.6 NA NA NA NA NA NA Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) RT-PRC034-EN 35 Performance Data Gross Cooling Capacities Table 10. Gross cooling capacities T/YS*250FD (SI) Ambient Temperature (°C) 30 Enter 16 Airflow DB m3/h (°C) TGC SHC 11380 12490 13590 14700 15800 35 40 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 66.1 54.9 70.9 39.4 77.7 27.2 61.5 52.4 66.3 38.0 73.0 25.6 56.4 49.4 61.1 36.0 67.7 23.7 27 68.6 64.1 72.3 52.1 77.9 31.6 64.5 61.4 68.1 50.5 73.7 31.1 59.8 58.2 63.4 48.4 68.9 30.1 30 70.8 70.8 73.4 62.7 77.9 45.7 67.2 67.2 69.7 60.9 74.1 45.0 63.0 63.0 65.4 58.6 69.9 43.8 33 72.7 72.7 74.1 71.1 77.5 57.7 69.6 69.6 71.0 69.2 74.3 56.8 66.5 65.9 67.2 66.6 70.5 55.4 24 67.6 56.6 72.1 41.1 78.6 27.5 62.9 54.1 67.4 39.7 73.8 25.8 57.8 51.1 62.2 37.8 68.6 24.0 27 70.1 65.9 73.5 53.9 78.9 33.4 66.0 63.2 69.3 52.3 74.7 32.9 61.4 60.0 64.6 50.2 69.9 31.9 30 72.4 72.4 74.7 64.5 78.9 47.6 68.8 68.8 71.0 62.8 75.2 46.9 64.7 64.7 66.8 60.5 70.9 45.7 33 74.5 74.5 75.6 73.0 78.7 59.6 71.4 71.4 72.4 71.1 75.5 58.8 68.0 68.0 68.7 68.7 71.7 57.4 24 68.8 58.2 73.0 42.7 79.2 27.7 64.2 55.8 68.4 41.4 74.5 26.1 59.1 52.9 63.2 39.5 69.3 24.3 27 71.5 67.6 74.6 55.6 79.7 35.1 67.4 65.0 70.4 54.1 75.5 34.7 62.8 61.9 65.7 52.0 70.7 33.7 30 73.9 73.9 75.9 66.3 79.8 49.3 70.3 70.3 72.2 64.6 76.1 48.8 66.2 66.2 68.0 62.4 71.8 47.6 33 76.1 76.1 76.9 74.9 79.7 61.5 73.0 73.0 73.7 73.0 76.5 60.7 70.0 70.0 70.0 70.0 72.7 59.4 24 69.9 59.8 73.8 44.3 79.7 27.9 65.3 57.5 69.2 43.0 75.1 26.3 60.2 54.6 64.0 41.2 69.8 24.4 27 72.7 69.3 75.5 57.3 80.3 36.7 68.6 66.7 71.4 55.8 76.1 36.4 64.0 63.6 66.7 53.8 71.4 35.5 30 75.2 75.2 76.9 68.1 80.5 51.1 71.6 71.6 73.3 66.4 76.9 50.6 67.5 67.5 69.1 64.3 72.6 49.5 33 77.5 77.5 78.0 76.7 80.5 63.3 74.9 74.9 74.9 74.9 77.3 62.6 71.2 71.2 71.2 71.2 73.6 61.3 24 70.8 61.4 74.5 45.8 80.1 28.0 66.3 59.1 69.9 44.6 75.4 26.4 61.2 56.2 64.7 42.8 70.2 24.6 27 73.8 70.9 76.3 58.9 80.7 38.4 69.7 68.4 72.1 57.5 76.6 38.1 65.1 65.1 67.5 55.5 71.9 37.2 30 76.4 76.4 77.8 69.8 81.1 52.8 72.8 72.8 74.1 68.2 77.4 52.3 68.7 68.7 70.0 66.1 73.2 51.3 33 78.2 78.2 79.0 78.5 81.2 65.1 75.9 75.9 75.9 75.9 78.0 64.4 72.2 72.2 72.2 72.2 74.3 63.2 Ambient Temperature (°C) 45 Enter 16 Airflow DB m3/h (°C) TGC SHC 11380 12490 13590 14700 15800 49 52 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 50.6 45.8 55.3 33.5 61.9 21.7 47.6 43.7 52.2 32.0 58.8 20.6 44.4 41.6 49.0 30.4 55.6 19.4 27 54.6 54.4 58.1 45.7 63.6 28.5 51.8 51.8 55.3 44.1 60.8 27.5 48.8 48.8 52.3 42.4 57.8 26.3 30 58.3 58.3 60.7 55.7 65.0 42.0 55.7 55.7 58.1 54.1 62.4 40.9 53.0 53.0 55.3 52.3 59.7 39.7 33 62.9 62.9 62.9 62.9 66.2 53.4 60.6 60.6 60.6 60.6 63.8 52.3 58.1 58.1 58.1 58.1 61.3 50.9 24 52.1 47.6 56.4 35.3 62.8 22.0 49.0 45.6 53.4 33.9 59.7 20.9 45.9 43.5 50.2 32.3 56.4 19.8 27 56.2 56.2 59.4 47.6 64.6 30.4 53.4 53.4 56.6 46.0 61.7 29.4 50.4 50.4 53.6 44.4 58.7 28.2 30 60.0 60.0 62.0 57.7 66.1 44.0 57.4 57.4 59.5 56.1 63.5 42.9 54.7 54.7 56.7 54.3 60.8 41.7 33 64.4 64.4 64.4 64.4 67.4 55.5 62.1 62.1 62.1 62.1 65.0 54.3 59.6 59.6 59.6 59.6 62.5 53.0 24 53.4 49.4 57.5 37.1 63.5 22.2 50.3 47.4 54.4 35.7 60.4 21.1 47.2 45.3 51.2 34.1 57.2 20.0 27 57.6 57.6 60.5 49.4 65.4 32.2 54.8 54.8 57.7 47.9 62.6 31.2 51.8 51.8 54.7 46.3 59.6 30.1 30 61.5 61.5 63.3 59.6 67.1 45.9 58.9 58.9 60.7 58.0 64.5 44.9 56.2 56.2 58.0 56.3 61.7 43.7 33 65.8 65.8 65.8 65.8 68.4 57.5 63.4 63.4 63.4 63.4 66.1 56.4 61.0 61.0 61.0 61.0 63.6 55.1 24 54.5 51.1 58.3 38.8 64.1 22.4 51.5 49.2 55.2 37.4 61.0 21.3 48.3 47.1 52.0 35.9 57.7 20.2 27 58.8 58.8 61.5 51.2 66.1 34.0 56.0 56.0 58.6 49.8 63.2 33.1 53.1 53.1 55.7 48.1 60.3 32.0 30 62.8 62.8 64.3 61.5 67.8 47.8 60.3 60.3 61.8 59.9 65.2 46.8 57.6 57.6 59.1 58.2 62.5 45.6 33 67.0 67.0 67.0 67.0 69.3 59.5 64.6 64.6 64.6 64.6 67.0 58.3 62.2 62.2 62.2 62.2 64.5 57.1 24 55.5 52.8 59.0 40.5 64.5 22.6 52.5 50.9 55.9 39.2 61.4 21.5 49.3 48.8 52.8 37.6 58.2 20.4 27 59.9 59.9 62.3 53.0 66.6 35.8 57.1 57.1 59.5 51.6 63.8 34.9 54.2 54.2 56.5 50.0 60.8 33.8 30 64.0 64.0 65.3 63.4 68.5 49.7 61.5 61.5 62.7 61.8 65.9 48.7 60.0 60.0 60.0 60.0 63.2 47.5 33 68.0 68.0 68.0 68.0 70.0 61.4 65.7 65.7 65.7 65.7 67.7 60.3 63.2 63.2 63.2 63.2 65.2 59.1 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) 36 RT-PRC034-EN Performance Data Gross Cooling Capacities Table 11. Gross cooling capacities T/YS*250FD (IP) Ambient Temperature (°F) 85 Enter 61 Airflow DB CFM (°F) TGC SHC 75 6700 7350 8000 8650 9300 95 105 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 225.7 187.4 242.0 134.4 265.2 92.8 209.9 178.9 226.1 129.6 249.1 87.2 192.3 168.4 208.3 122.9 231.1 80.9 80 234.1 218.8 246.6 177.8 265.9 107.9 220.0 209.6 232.4 172.4 251.5 106.2 204.1 198.6 216.3 165.1 235.2 102.6 85 241.6 241.6 250.3 213.9 265.7 156.0 229.2 229.2 237.7 207.9 252.9 153.7 215.0 215.0 223.3 199.9 238.3 149.5 90 248.2 248.2 253.0 242.6 264.5 196.8 237.5 237.5 242.1 235.9 253.4 193.9 227.0 224.9 229.3 227.4 240.5 189.0 75 230.5 193.1 245.8 140.1 268.0 93.8 214.7 184.7 230.0 135.4 251.9 88.2 197.2 174.5 212.2 128.9 234.0 81.9 80 239.3 224.8 250.8 183.8 269.1 113.8 225.3 215.8 236.6 178.5 254.7 112.3 209.4 204.9 220.5 171.4 238.5 108.9 85 247.2 247.2 254.8 220.2 269.2 162.3 234.8 234.8 242.3 214.3 256.5 160.1 220.6 220.6 227.9 206.5 242.0 156.0 90 254.1 254.1 257.9 249.1 268.4 203.3 243.5 243.5 247.1 242.6 257.4 200.5 232.0 232.0 234.4 234.2 244.6 195.9 75 234.7 198.7 249.1 145.7 270.3 94.6 219.1 190.5 233.3 141.2 254.3 89.0 201.5 180.4 215.6 134.8 236.4 82.7 80 243.9 230.6 254.5 189.7 271.8 119.7 230.0 221.8 240.3 184.5 257.4 118.3 214.1 211.1 224.3 177.5 241.2 115.0 85 252.2 252.2 258.9 226.3 272.3 168.4 239.9 239.9 246.4 220.5 259.6 166.3 225.7 225.7 232.1 212.9 245.1 162.5 90 259.5 259.5 262.3 255.5 271.9 209.7 248.9 248.9 251.5 249.2 260.9 207.0 238.9 238.9 238.9 238.9 248.1 202.5 75 238.5 204.2 251.9 151.1 272.0 95.2 222.9 196.1 236.1 146.8 256.1 89.6 205.4 186.2 218.4 140.5 238.2 83.4 80 248.1 236.4 257.6 195.4 273.9 125.4 234.1 227.7 243.5 190.4 259.6 124.1 218.3 217.1 227.5 183.6 243.5 121.0 85 256.7 256.7 262.4 232.3 274.8 174.3 244.5 244.5 249.9 226.7 262.2 172.5 230.3 230.3 235.7 219.2 247.8 168.7 90 264.4 264.4 266.2 261.8 274.8 215.9 255.5 255.5 255.5 255.5 263.9 213.4 242.9 242.9 242.9 242.9 251.1 209.1 75 241.7 209.5 254.1 156.4 273.3 95.6 226.1 201.6 238.4 152.2 257.4 90.1 208.7 191.8 220.7 146.2 239.6 83.9 80 251.7 242.0 260.2 201.0 275.5 130.9 237.8 233.4 246.1 196.1 261.3 129.9 222.0 222.0 230.2 189.5 245.2 126.9 85 260.7 260.7 265.3 238.1 276.8 180.2 248.5 248.5 253.0 232.7 264.2 178.5 234.4 234.4 238.7 225.4 249.8 174.9 90 266.9 266.9 269.5 267.9 277.1 222.0 258.9 258.9 258.9 258.9 266.3 219.7 246.3 246.3 246.3 246.3 253.6 215.5 Ambient Temperature (°F) 115 Enter 61 Airflow DB CFM (°F) TGC SHC 6700 7350 8000 8650 9300 120 125 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 75 172.8 156.1 188.6 114.3 211.3 73.9 162.3 149.2 178.1 109.3 200.7 70.2 151.4 141.9 167.1 103.8 189.6 66.4 80 186.3 185.6 198.3 155.9 217.0 97.1 176.7 176.7 188.6 150.6 207.3 93.7 166.6 166.6 178.5 144.8 197.0 89.8 85 198.9 198.9 207.0 190.1 221.9 143.4 190.1 190.1 198.1 184.5 213.0 139.7 180.9 180.9 188.8 178.4 203.6 135.4 90 214.7 214.7 214.7 214.7 225.8 182.3 206.7 206.7 206.7 206.7 217.7 178.3 198.3 198.3 198.3 198.3 209.1 173.8 75 177.7 162.3 192.6 120.5 214.2 75.0 167.3 155.5 182.1 115.5 203.6 71.3 156.4 148.3 171.1 110.2 192.6 67.4 80 191.6 191.6 202.6 162.3 220.4 103.5 182.0 182.0 193.0 157.1 210.6 100.2 172.0 172.0 182.8 151.4 200.4 96.4 85 204.6 204.6 211.7 196.8 225.6 150.1 195.8 195.8 202.9 191.3 216.7 146.5 186.6 186.6 193.6 185.3 207.3 142.3 90 219.8 219.8 219.8 219.8 229.9 189.3 211.9 211.9 211.9 211.9 221.8 185.3 203.4 203.4 203.4 203.4 213.3 180.9 75 182.1 168.4 196.0 126.5 216.7 75.8 171.8 161.7 185.5 121.7 206.1 72.1 160.9 154.5 174.6 116.4 195.1 68.3 80 196.4 196.4 206.4 168.7 223.2 109.9 186.9 186.9 196.8 163.5 213.5 106.6 176.9 176.9 186.7 157.9 203.3 102.8 85 209.7 209.7 215.9 203.4 228.8 156.7 201.0 201.0 207.1 198.0 219.9 153.1 191.9 191.9 197.8 192.1 210.6 149.1 90 224.4 224.4 224.4 224.4 233.4 196.2 216.4 216.4 216.4 216.4 225.4 192.3 208.0 208.0 208.0 208.0 216.9 187.9 75 186.0 174.3 198.9 132.4 218.6 76.5 175.7 167.7 188.5 127.7 208.0 72.8 164.8 160.6 177.6 122.5 197.0 69.0 80 200.7 200.7 209.7 174.9 225.5 116.0 191.2 191.2 200.1 169.8 215.8 112.8 181.2 181.2 190.0 164.3 205.6 109.2 85 214.4 214.4 219.5 209.9 231.4 163.1 205.7 205.7 210.8 204.5 222.6 159.6 196.6 196.6 201.5 198.7 213.3 155.7 90 228.4 228.4 228.4 228.4 236.5 202.9 220.5 220.5 220.5 220.5 228.5 199.1 212.1 212.1 212.1 212.1 220.0 194.8 75 189.4 180.1 201.3 138.2 219.9 77.0 179.1 173.6 190.9 133.6 209.4 73.3 168.3 166.6 180.0 128.4 198.5 69.5 80 204.4 204.4 212.4 180.9 227.2 122.1 194.9 194.9 202.9 175.9 217.6 119.0 185.0 185.0 192.8 170.5 207.4 115.4 85 218.5 218.5 222.7 216.2 233.6 169.5 209.9 209.9 213.9 210.9 224.8 166.1 204.7 204.7 204.7 204.7 215.5 162.2 90 231.9 231.9 231.9 231.9 239.0 209.5 224.0 224.0 224.0 224.0 231.0 205.8 215.7 215.7 215.7 215.7 222.6 201.6 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) RT-PRC034-EN 37 Performance Data Gross Cooling Capacities Table 12. Gross cooling capacities WS*155ED, ET (SI) Ambient Temperature (°C) 30 Enter 16 Airflow DB m3/h (°C) TGC SHC 7650 8500 9350 10200 35 40 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 44.4 36.8 47.8 25.6 49.0 12.5 39.5 34.6 46.8 26.1 49.0 14.0 33.5 31.8 43.6 25.3 48.1 14.7 27 45.7 44.0 47.8 33.0 49.1 19.8 42.1 42.1 47.0 33.5 49.3 21.1 37.6 37.6 43.8 32.6 48.4 22.4 30 47.2 47.2 48.1 40.3 49.4 27.3 45.7 45.7 47.3 41.0 49.5 28.2 42.5 42.5 44.4 40.0 48.6 29.8 33 48.5 48.5 48.6 46.3 49.3 34.0 47.9 47.9 48.1 46.7 49.7 35.6 46.3 46.3 46.5 46.4 48.9 37.0 24 45.7 39.4 48.0 26.6 49.2 11.8 41.8 37.4 47.2 27.1 49.4 12.8 35.7 34.5 44.7 26.6 48.5 14.2 27 46.7 45.8 48.2 34.6 49.4 19.7 44.2 44.2 47.5 35.4 49.6 20.7 40.9 40.9 44.9 34.9 48.8 22.5 30 48.1 48.1 48.5 41.7 49.6 27.6 47.3 47.3 48.0 43.2 49.8 28.8 44.9 44.9 46.1 43.0 49.0 30.5 33 49.2 49.2 48.9 47.6 49.8 34.7 48.9 48.9 48.9 48.4 49.8 37.0 47.8 47.8 47.8 47.8 49.3 38.9 24 46.4 41.1 48.3 26.8 49.3 10.7 43.1 39.8 47.7 28.0 49.4 12.5 37.7 37.0 45.5 27.6 48.9 14.3 27 47.2 46.9 48.2 34.7 49.4 18.4 46.2 46.2 48.0 37.0 49.9 21.3 42.8 42.8 45.9 37.0 49.2 23.1 30 48.3 48.6 48.8 43.3 49.9 27.8 48.1 48.1 48.4 44.6 50.0 30.3 46.8 46.8 47.1 45.0 49.4 32.3 33 49.6 49.6 48.9 48.9 50.0 35.0 49.6 49.6 49.4 49.4 50.3 39.2 48.7 48.7 48.7 48.7 49.7 41.0 24 47.1 42.7 48.4 26.6 49.4 9.0 44.5 42.2 48.0 28.5 49.8 12.4 39.6 39.4 46.1 28.7 49.2 13.8 27 47.9 47.9 48.6 36.1 49.6 18.7 47.2 47.2 48.2 38.1 50.1 22.0 44.3 44.3 46.7 38.9 49.5 23.6 30 49.0 49.0 48.8 45.0 49.9 27.8 48.8 48.8 48.7 45.9 50.3 31.7 47.6 47.6 47.8 46.6 49.6 33.3 33 49.8 49.8 49.5 49.5 50.0 36.1 50.1 50.1 50.1 50.1 50.5 40.6 49.4 49.4 49.4 49.4 50.1 42.5 Ambient Temperature (°C) 45 Entering Wet Bulb Temperature (°C) Enter 16 Airflow DB m3/h (°C) TGC SHC 7650 8500 9350 10200 19 22 TGC SHC TGC SHC 24 28.7 28.7 37.5 22.7 45.9 14.6 27 33.3 33.3 38.1 30.4 46.1 22.0 30 38.6 38.6 39.6 37.9 46.4 29.6 33 43.1 43.1 43.2 43.2 46.6 36.9 24 30.7 30.7 38.9 24.2 46.5 14.8 27 36.0 36.0 39.3 32.6 46.7 22.9 30 41.3 41.3 41.8 41.1 47.0 31.3 33 45.4 45.4 45.5 45.5 47.3 39.5 24 32.6 32.6 40.3 25.7 47.0 14.7 27 38.3 38.3 40.8 35.0 47.2 23.7 30 43.3 43.3 43.6 43.4 47.4 32.9 33 46.9 46.9 47.0 47.0 47.7 41.6 24 34.3 34.3 41.5 27.3 47.3 14.5 27 40.1 40.1 42.3 37.4 47.6 24.7 30 45.1 45.1 45.2 45.2 47.8 34.6 33 47.8 47.8 47.8 47.8 48.4 43.5 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) 38 RT-PRC034-EN Performance Data Gross Cooling Capacities Table 13. Gross cooling capacities WS*155ED, ET (IP) Ambient Temperature (°C) 30 Enter 16 Airflow DB m3/h (°C) TGC SHC 24 7650 8500 9350 10200 35 40 Entering Wet Bulb Temperature (°C) 19 TGC SHC 22 TGC SHC 16 TGC SHC 19 TGC SHC 22 TGC SHC 16 TGC SHC 19 TGC SHC 22 TGC SHC 151.6 125.7 163.0 87.3 167.2 42.6 134.7 118.0 159.6 89.1 167.3 47.9 114.5 108.6 148.8 86.3 164.2 50.3 27 155.8 150.2 163.1 112.5 167.6 67.6 143.7 143.7 160.4 114.2 168.2 72.1 128.3 128.3 149.4 111.1 165.1 76.4 30 161.0 161.0 164.2 137.3 168.4 93.0 155.9 155.9 161.4 139.8 168.8 96.1 145.0 145.0 151.6 136.6 165.8 101.6 33 165.3 165.3 165.9 157.8 168.3 115.9 163.5 163.5 164.2 159.2 169.6 121.4 158.1 158.1 158.6 158.2 166.8 126.3 24 156.0 134.3 163.8 90.9 167.8 40.1 142.5 127.7 161.2 92.4 168.4 43.7 121.7 117.6 152.4 90.8 165.5 48.6 27 159.3 156.3 164.4 117.9 168.7 67.3 150.7 150.7 162.2 120.6 169.2 70.8 139.5 139.5 153.3 119.2 166.6 76.8 30 164.0 164.0 165.4 142.2 169.3 94.2 161.4 161.4 163.7 147.5 170.0 98.3 153.1 153.1 157.2 146.8 167.3 104.2 33 167.8 167.8 166.8 162.5 169.9 118.5 166.8 166.8 166.7 165.2 170.0 126.3 163.1 163.1 163.2 163.2 168.2 132.9 24 158.3 140.1 164.6 91.3 168.2 36.6 147.2 135.8 162.7 95.6 168.5 42.7 128.6 126.4 155.1 94.3 167.0 48.9 27 161.2 159.9 164.5 118.5 168.6 62.9 157.7 157.7 163.6 126.2 170.3 72.8 145.9 145.9 156.7 126.1 167.8 78.9 30 164.9 165.7 166.6 147.6 170.2 95.0 164.1 164.1 165.2 152.1 170.7 103.3 159.5 159.5 160.8 153.6 168.4 110.2 33 169.2 169.2 166.8 166.8 170.6 119.4 169.2 169.2 168.7 168.7 171.5 133.7 166.1 166.1 166.2 166.2 169.7 139.7 24 160.6 145.8 165.0 90.9 168.6 30.8 151.9 143.8 163.6 97.2 170.1 42.4 135.1 134.3 157.4 97.9 168.0 46.9 27 163.4 163.4 165.9 123.0 169.4 63.8 161.0 161.0 164.5 130.0 171.1 75.0 151.1 151.1 159.3 132.6 168.8 80.7 30 167.0 167.0 166.5 153.6 170.2 94.8 166.4 166.4 166.3 156.5 171.6 108.2 162.5 162.5 163.2 158.9 169.3 113.6 33 169.9 169.9 169.0 169.0 170.6 123.2 170.9 170.9 170.9 170.9 172.2 138.4 168.5 168.5 168.6 168.6 171.0 144.9 Ambient Temperature (°C) 45 Entering Wet Bulb Temperature (°C) Enter 16 Airflow DB m3/h (°C) TGC SHC 24 7650 8500 9350 10200 97.9 19 TGC SHC 22 TGC SHC 97.9 127.9 77.6 156.5 49.9 27 113.7 113.7 129.9 103.7 157.4 75.2 30 131.6 131.6 135.1 129.4 158.3 100.9 33 147.1 147.1 147.3 147.3 159.1 126.0 24 104.7 104.7 132.8 82.6 158.6 50.6 27 122.7 122.7 134.0 111.3 159.3 78.2 30 141.0 141.0 142.7 140.1 160.2 106.9 33 155.0 155.0 155.4 155.4 161.4 134.9 24 111.2 111.2 137.4 87.6 160.2 50.2 27 130.8 130.8 139.0 119.5 161.0 81.0 30 147.9 147.9 148.7 148.0 161.8 112.4 33 160.0 160.0 160.3 160.3 162.8 142.1 24 117.2 117.2 141.7 93.3 161.4 49.4 27 136.7 136.7 144.2 127.5 162.3 84.1 30 153.7 153.7 154.1 154.1 163.2 118.0 33 163.2 163.2 163.1 163.1 165.2 148.4 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) RT-PRC034-EN 39 Performance Data Gross Cooling Capacities Table 14. Gross cooling capacities WS*200ED, ET (SI) Ambient Temperature (°C) 30 Enter 16 Airflow DB m3/h (°C) TGC SHC 10100 11220 12340 13460 35 40 Entering Wet Bulb Temperature (°C) 19 22 16 19 22 16 19 22 TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 56.4 47.3 67.8 36.0 74.3 20.5 49.7 44.6 62.9 34.5 71.1 20.2 43.6 42.2 57.0 32.5 66.8 19.5 27 58.0 57.4 68.2 45.9 75.1 30.6 52.9 52.9 63.4 44.4 71.6 30.2 48.7 48.7 57.4 42.4 67.2 29.5 30 62.9 62.9 68.9 56.0 76.0 40.9 59.2 59.2 64.3 54.5 72.4 40.5 55.3 55.3 58.2 52.6 67.7 39.6 33 68.4 68.4 70.0 66.3 76.9 51.2 64.9 64.9 65.8 64.8 73.0 50.8 60.7 60.7 60.8 60.8 68.3 49.8 24 59.1 50.7 69.3 37.3 75.3 19.9 52.4 48.2 65.0 36.0 72.0 19.4 46.1 45.5 58.7 34.2 67.9 18.8 27 61.0 61.0 69.9 48.4 76.1 30.9 56.8 56.8 65.4 47.1 72.7 30.7 52.4 52.4 59.3 45.2 68.4 30.2 30 66.9 66.9 70.7 59.6 77.1 42.3 62.6 62.6 66.3 58.3 73.6 42.1 58.5 58.5 60.3 56.6 69.1 41.5 33 71.5 71.5 72.3 70.8 78.2 53.7 68.1 68.1 68.3 68.2 74.5 53.5 64.3 64.3 64.4 64.4 69.9 52.9 24 61.1 53.9 70.6 38.4 75.7 18.7 55.0 51.6 66.2 37.3 72.7 18.7 48.3 48.2 60.5 35.8 68.7 18.6 27 63.8 63.8 71.3 50.7 76.9 31.3 59.8 59.8 66.9 49.6 73.6 31.4 55.4 55.4 61.2 48.0 69.4 31.0 30 69.5 69.5 72.3 63.1 78.0 43.8 65.9 65.9 67.9 62.0 74.5 43.7 61.4 61.4 63.0 60.6 70.2 43.3 33 74.1 74.1 74.4 74.1 79.2 56.4 70.6 70.6 70.8 70.8 75.7 56.3 66.8 66.8 66.9 66.9 71.2 55.9 24 62.8 57.0 71.6 39.6 76.3 18.3 57.3 54.9 67.3 38.7 73.3 18.5 50.7 50.7 62.1 37.4 69.3 18.2 27 66.8 66.8 72.5 53.0 77.4 31.8 62.2 62.2 68.0 52.1 74.3 31.9 57.8 57.8 63.0 50.8 70.2 31.8 30 71.6 71.6 73.7 66.4 78.7 45.3 68.0 68.0 69.4 65.5 75.4 45.4 64.1 64.1 64.6 63.8 71.0 45.2 33 76.2 76.2 76.3 76.3 80.0 58.7 72.8 72.8 72.9 72.9 76.7 59.0 68.9 68.9 69.0 69.0 72.2 59.0 Ambient Temperature (°C) 45 Entering Wet Bulb Temperature (°C) Enter 16 Airflow DB m3/h (°C) TGC SHC 10100 11220 12340 13460 19 22 TGC SHC TGC SHC 24 38.3 38.3 50.6 30.4 61.7 18.2 27 44.5 44.5 51.1 40.4 62.0 28.2 30 51.0 51.0 52.4 50.7 62.4 38.3 33 56.5 56.5 56.6 56.6 62.9 48.5 24 41.0 41.0 52.6 32.2 62.8 18.3 27 47.7 47.7 53.1 43.3 63.2 29.2 30 54.2 54.2 54.7 54.3 63.7 40.4 33 59.9 59.9 60.0 60.0 64.4 51.8 24 43.2 43.2 54.0 33.9 63.7 17.9 27 50.6 50.6 54.7 46.1 64.2 30.3 30 56.6 56.6 56.8 56.8 64.8 42.6 33 62.5 62.5 62.6 62.6 65.7 55.1 24 45.6 45.6 55.1 35.5 64.4 17.6 27 53.1 53.1 55.9 48.8 65.0 31.1 30 59.3 59.3 59.4 59.4 65.7 44.6 33 64.5 64.5 64.6 64.6 66.8 58.4 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) 40 RT-PRC034-EN Performance Data Gross Cooling Capacities Table 15. Gross cooling capacities WS*200ED, ET (IP) Ambient Temperature (°F) 85 Enter 61 Airflow DB CFM (°F) TGC SHC 75 5950 6600 7250 7900 95 105 Entering Wet Bulb Temperature (°F) 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 61 TGC SHC 67 TGC SHC 73 TGC SHC 192.6 161.3 231.2 122.7 253.7 69.8 169.6 152.2 214.6 117.5 242.5 68.8 148.6 144.0 194.5 110.8 227.9 66.4 80 197.9 195.8 232.5 156.5 256.4 104.5 180.6 180.6 216.3 151.4 244.4 102.9 166.2 166.2 196.0 144.8 229.2 100.7 85 214.5 214.5 235.0 191.1 259.3 139.6 202.0 202.0 219.3 186.1 246.9 138.0 188.6 188.6 198.6 179.4 231.1 135.1 90 233.2 233.2 238.7 226.2 262.4 174.5 221.5 221.5 224.5 221.1 249.1 173.3 207.0 207.0 207.4 207.4 233.1 169.8 75 201.8 173.1 236.6 127.1 256.8 67.7 178.9 164.4 221.7 122.9 245.6 66.1 157.2 155.3 200.4 116.5 231.6 64.3 80 208.3 208.1 238.5 165.0 259.7 105.4 193.9 193.9 223.3 160.7 248.1 104.9 178.6 178.6 202.4 154.3 233.4 103.1 85 228.3 228.3 241.2 203.4 263.2 144.2 213.7 213.7 226.1 199.0 251.1 143.8 199.6 199.6 205.9 193.0 235.8 141.6 90 243.8 243.8 246.8 241.7 266.9 183.2 232.3 232.3 232.9 232.7 254.1 182.7 219.3 219.3 219.8 219.8 238.6 180.6 75 208.5 183.9 240.9 131.1 258.3 63.7 187.6 176.1 225.8 127.4 248.0 63.9 164.9 164.6 206.3 122.2 234.5 63.5 80 217.7 217.7 243.1 173.0 262.3 106.7 203.9 203.9 228.1 169.3 251.2 107.1 189.0 189.0 208.9 163.9 236.8 105.8 85 237.1 237.1 246.7 215.1 266.2 149.4 224.9 224.9 231.5 211.6 254.3 149.1 209.5 209.5 214.9 206.7 239.4 147.8 90 252.8 252.8 253.7 252.8 270.4 192.3 240.9 240.9 241.5 241.5 258.3 192.1 227.8 227.8 228.2 228.2 242.8 190.7 75 214.3 194.4 244.2 135.0 260.2 62.3 195.5 187.3 229.5 132.1 250.0 63.3 172.9 172.9 212.0 127.7 236.5 62.1 80 228.0 228.0 247.2 180.8 264.0 108.3 212.4 212.4 232.1 177.7 253.5 108.9 197.2 197.2 214.9 173.2 239.4 108.6 85 244.4 244.4 251.4 226.6 268.3 154.5 232.0 232.0 236.6 223.6 257.1 154.8 218.8 218.8 220.6 217.8 242.4 154.2 90 259.9 259.9 260.4 260.4 272.9 200.3 248.4 248.4 248.6 248.6 261.5 201.3 235.2 235.2 235.5 235.5 246.4 201.3 Ambient Temperature (°F) 115 Entering Wet Bulb Temperature (°F) Enter 61 Airflow DB CFM (°F) TGC SHC 5950 6600 7250 7900 67 TGC SHC 73 TGC SHC 75 130.5 130.5 172.8 103.7 210.4 62.2 80 152.0 152.0 174.4 137.7 211.4 96.3 85 173.9 173.9 178.7 173.0 212.8 130.6 90 192.8 192.8 193.1 193.1 214.8 165.5 75 139.9 139.9 179.4 109.9 214.3 62.3 80 162.7 162.7 181.3 147.7 215.7 99.8 85 184.8 184.8 186.6 185.3 217.2 137.9 90 204.4 204.4 204.8 204.8 219.6 176.8 75 147.4 147.4 184.2 115.6 217.2 61.2 80 172.5 172.5 186.5 157.3 219.0 103.3 85 193.3 193.3 193.9 193.9 221.1 145.3 90 213.1 213.1 213.5 213.5 224.0 188.0 75 155.5 155.5 188.1 121.1 219.7 60.1 80 181.1 181.1 190.7 166.6 221.7 106.0 85 202.2 202.2 202.8 202.8 224.3 152.3 90 219.9 219.9 220.3 220.3 227.8 199.1 Notes: 1. All capacities shown are gross and have not considered indoor fan heat. 2. TGC = Total gross capacity (kW) 3. SHC = Sensible heat capacity (kW) RT-PRC034-EN 41 Performance Data Heating Capacities Table 16. WS*155ED, ET net heating capacities (kW)—8500 m3/h—(SI) Outdoor Peak Net Heating (kW) Peak Total Power (kW) Temp (°C) at Indicated Dry Bulb (°C) at Indicated Dry Bulb (°C) 70% RH 15 21 24 27 15 21 24 27 -24 13.8 13.4 13.2 13.0 10.5 11.5 12.0 12.5 -21 15.3 14.9 14.7 14.5 10.7 11.7 12.1 12.7 -18 17.0 16.5 16.3 16.0 10.9 11.8 12.4 12.9 -15 18.6 17.4 17.1 17.3 11.1 12.0 12.5 14.0 -12 20.2 17.8 18.8 18.8 12.0 12.1 12.7 13.7 -9 21.5 20.9 20.5 20.2 11.4 12.4 12.9 13.5 -6 23.4 22.7 22.3 21.9 11.6 12.5 13.1 13.7 -3 25.4 24.6 24.2 23.8 11.8 12.7 13.3 13.9 0 27.4 26.6 26.2 25.8 11.9 13.0 13.5 14.1 3 29.5 28.6 28.2 27.8 12.1 13.2 13.8 14.4 6 36.1 35.1 34.5 34.0 12.2 13.3 13.9 14.5 9 43.8 42.4 41.7 41.0 12.6 13.6 14.2 14.8 12 46.6 45.3 44.5 43.7 12.8 13.9 14.4 15.0 15 49.8 48.3 47.4 46.8 13.1 14.1 14.7 15.3 18 53.2 51.4 50.7 49.8 13.4 14.4 15.0 15.6 21 57.0 55.1 54.0 53.0 13.7 14.8 15.4 16.0 24 60.5 58.6 57.5 56.5 14.1 15.2 15.8 16.4 Notes: 1. For other airflow conditions, see heating capacity correction factor 2. Net Heating Capacity and Power Input include indoor fan heat at nominal cfm and 0.35 inch ESP. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. 3. Heating capacities and powers are integrated to include the effects of defrost in the frost region. Table 17. WS*155ED, ET net heating capacities (MBh)—5000 cfm (IP) Outdoor Peak Net Heating (MBh) Peak Total Power (kW) Temp (°F) at Indicated Dry Bulb (°F) at Indicated Dry Bulb (°F) 70% RH 60 70 75 80 60 70 75 80 -8 46.9 45.7 45.0 44.4 10.5 11.5 12.0 12.5 -3 52.4 51.0 50.2 49.5 10.7 11.7 12.1 12.7 2 57.9 56.3 55.5 54.7 10.9 11.8 12.4 12.9 7 63.5 59.2 58.2 59.0 11.1 12.0 12.5 14.0 12 69.0 60.9 64.1 64.1 12.0 12.1 12.7 13.7 17 73.5 71.2 70.0 68.9 11.4 12.4 12.9 13.5 22 79.9 77.3 76.1 74.9 11.6 12.5 13.1 13.7 27 86.5 83.8 82.4 81.1 11.8 12.7 13.3 13.9 32 93.6 90.8 89.2 87.9 11.9 13.0 13.5 14.1 37 100.6 97.5 96.2 94.7 12.1 13.2 13.8 14.4 42 123.3 119.7 117.8 116.0 12.2 13.3 13.9 14.5 47 149.3 144.8 142.4 140.0 12.6 13.6 14.2 14.8 52 159.0 154.4 151.9 149.2 12.8 13.9 14.4 15.0 57 170.0 164.7 161.8 159.6 13.1 14.1 14.7 15.3 62 181.5 175.5 172.9 169.7 13.4 14.4 15.0 15.6 67 194.6 187.9 184.2 180.8 13.7 14.8 15.4 16.0 72 206.5 199.8 196.2 192.6 14.1 15.2 15.8 16.4 Notes: 1. For other airflow conditions, see heating capacity correction factor 2. Net Heating Capacity and Power Input include indoor fan heat at nominal cfm and 0.35 inch ESP. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. 3. Heating capacities and powers are integrated to include the effects of defrost in the frost region. 42 RT-PRC034-EN Performance Data Heating Capacities Table 18. WS*200ED, ET net heating capacities (kW)—11210 m3/h—(SI) Outdoor Peak Net Heating (kW) Peak Total Power (kW) Temp (°C) at Indicated Dry Bulb (°C) at Indicated Dry Bulb (°C) 70% RH 15 21 24 27 15 21 24 27 -24 21.3 20.7 20.5 20.3 15.1 15.9 16.4 16.9 -21 23.1 22.5 22.3 22.0 15.3 16.0 16.5 17.0 -18 25.4 24.8 24.5 24.2 15.4 16.2 16.7 17.2 -15 28.0 27.2 27.0 26.6 15.5 16.3 16.8 17.3 -12 31.2 30.7 30.5 30.3 15.7 16.5 17.0 17.5 -9 34.6 33.8 33.6 33.3 15.9 16.7 17.2 17.7 -6 37.7 37.0 36.6 36.2 16.1 16.9 17.4 17.9 -3 40.7 39.9 39.6 39.2 16.4 17.3 17.8 18.3 0 43.7 42.8 42.5 42.1 16.5 17.4 17.9 18.4 3 47.7 46.8 46.3 46.0 16.8 17.7 18.2 18.7 6 51.8 50.6 50.1 49.6 17.0 17.9 18.4 18.9 9 56.3 55.2 54.6 54.2 17.1 18.0 18.5 19.0 12 60.4 59.1 58.4 58.0 17.4 18.3 18.8 19.3 15 64.2 62.7 62.1 61.5 17.8 18.8 19.3 19.8 18 69.1 67.5 66.6 65.9 20.0 21.1 21.6 22.1 21 73.8 71.8 70.9 70.0 20.1 21.2 21.7 22.2 24 78.7 76.8 75.9 74.9 20.4 21.5 22.0 22.6 Notes: 1. For other airflow conditions, see heating capacity correction factor 2. Net Heating Capacity and Power Input include indoor fan heat at nominal cfm and 0.35 inch ESP. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. 3. Heating capacities and powers are integrated to include the effects of defrost in the frost region. Table 19. WS*200ED, ET net heating capacities (MBh)—6600 cfm (IP) Outdoor Peak Net Heating (MBh) Peak Total Power (kW) Temp (°F) at Indicated Dry Bulb (°F) at Indicated Dry Bulb (°F) 70% RH 60 70 75 80 60 70 75 80 -8 72.5 70.6 69.8 69.1 15.1 15.9 16.4 16.9 -3 78.8 76.8 76.1 75.1 15.3 16.0 16.5 17.0 2 86.7 84.5 83.5 82.5 15.4 16.2 16.7 17.2 7 95.4 92.9 92.1 90.9 15.5 16.3 16.8 17.3 12 106.5 104.6 104.0 103.2 15.7 16.5 17.0 17.5 17 118.0 115.4 114.7 113.7 15.9 16.7 17.2 17.7 22 128.6 126.3 124.9 123.5 16.1 16.9 17.4 17.9 27 138.7 136.2 135.0 133.7 16.4 17.3 17.8 18.3 32 149.0 146.2 145.1 143.6 16.5 17.4 17.9 18.4 37 162.8 159.8 158.1 157.1 16.8 17.7 18.2 18.7 42 176.9 172.7 170.8 169.4 17.0 17.9 18.4 18.9 47 192.0 188.2 186.3 184.9 17.1 18.0 18.5 19.0 52 206.0 201.8 199.3 197.8 17.4 18.3 18.8 19.3 57 219.1 213.9 212.0 209.7 17.8 18.8 19.3 19.8 62 235.7 230.1 227.3 225.0 20.0 21.1 21.6 22.1 67 251.6 244.8 242.0 238.8 20.1 21.2 21.7 22.2 72 268.7 262.0 259.1 255.4 20.4 21.5 22.0 22.6 Notes: 1. For other airflow conditions, see heating capacity correction factor 2. Net Heating Capacity and Power Input include indoor fan heat at nominal cfm and 0.35 inch ESP. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. 3. Heating capacities and powers are integrated to include the effects of defrost in the frost region. RT-PRC034-EN 43 Performance Data Fan Performance Table 20. Evaporator fan performance TS*155F downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 m3/h RPM kW 50.00 RPM kW 75.00 RPM kW 100.00 RPM kW 125.00 150.00 RPM kW RPM 1.49 Nom kW Standard Motor & Low Static Drive Accessory kW 175.00 RPM kW 200.00 RPM kW 225.00 RPM 250.00 kW RPM kW 1.49 Nom kw Standard Motor & High Static Drive Accessory 7140 — — 393 0.46 430 0.54 467 0.64 503 0.74 536 0.84 570 0.95 601 1.06 630 1.18 659 1.31 7820 376 0.48 416 0.58 451 0.66 484 0.75 518 0.86 551 0.97 581 1.08 612 1.20 642 1.32 669 1.45 8500 400 0.60 440 0.70 473 0.80 504 0.89 534 1.00 566 1.12 597 1.24 625 1.35 653 1.48 681 1.61 9180 425 0.73 464 0.85 496 0.96 525 1.06 554 1.16 582 1.28 611 1.41 640 1.54 666 1.66 692 1.79 9860 450 0.89 488 1.01 520 1.14 548 1.24 575 1.35 601 1.47 627 1.59 654 1.73 681 1.87 707 2.01 1.49 Nom kw Standard Motor Drive 2.24 Nom kw Oversized Motor & Drive Continued External Static Pressure (Pascals) 275.00 m3/h RPM kW 300.00 RPM kW 325.00 RPM kW 350.00 RPM kW 375.00 400.00 RPM kW RPM kW 1.49 Nom kw Standard Motor & High Static Drive Accessory 425.00 RPM kW 450.00 RPM kW 475.00 RPM 500.00 kW RPM kW 2.24 Nom kw Oversized Motor & Drive 7140 686 1.44 713 1.56 738 1.69 763 1.82 786 1.95 809 2.08 831 2.21 852 2.34 — — — 7820 696 1.58 722 1.72 747 1.86 771 2.00 795 2.14 818 2.28 840 2.42 — — — — — — — 8500 707 1.75 732 1.88 757 2.03 780 2.18 804 2.33 826 2.49 — — — — — — — — 9180 718 1.93 744 2.08 768 2.22 791 2.37 813 2.53 — — — — — — — — — — 9860 730 2.14 754 2.29 779 2.44 — — — — — — — — — — — — — — Note: Data includes pressure drop for filters and wet coil. Table 21. Evaporator fan performance TS*155F downflow or horizontal (IP) External Static Pressure (Inches of Water Pressure) .10 CFM .20 .30 .40 .50 .60 .70 .80 .90 1.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2HP Standard Motor & Low Static Drive Accessory 2HP Standard Motor & High Static Drive Accessory 4000 — — 382 0.56 420 0.66 459 0.79 496 0.91 531 1.05 564 1.19 595 1.34 625 1.50 654 1.67 4500 — — 410 0.73 446 0.85 479 0.97 514 1.11 548 1.26 578 1.40 610 1.56 639 1.72 666 1.89 5000 400 0.80 440 0.95 473 1.07 504 1.20 534 1.34 566 1.50 597 1.66 625 1.81 653 1.98 681 2.16 5500 431 1.03 470 1.19 502 1.34 531 1.48 559 1.62 586 1.77 615 1.95 643 2.12 670 2.30 695 2.47 6000 463 1.30 500 1.48 531 1.65 559 1.80 585 1.95 611 2.11 636 2.28 662 2.46 689 2.66 714 2.85 2HP Standard Motor Drive 3HP Oversized Motor & Drive Continued External Static Pressure (Inches of Water Pressure) 1.10 CFM 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2HP Standard Motor & High Static Drive Accessory 3HP Oversized Motor & Drive 4000 682 1.83 708 1.99 734 2.16 758 2.32 782 2.49 804 2.66 826 2.83 847 3.01 — — — — 4500 693 2.07 719 2.25 745 2.44 769 2.62 793 2.80 815 2.99 838 3.17 — — — — — — 5000 707 2.34 732 2.53 757 2.72 780 2.92 804 3.13 826 3.33 — — — — — — — — 5500 721 2.66 747 2.86 771 3.05 794 3.26 — — — — — — — — — — — — 6000 738 3.04 760 3.22 784 3.43 — — — — — — — — — — — — — — Note: Data includes pressure drop for filters and wet coil. 44 RT-PRC034-EN Performance Data Fan Performance Table 22. Evaporator fan performance TS*175F downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 m3/h RPM kW 50.00 RPM kW 75.00 RPM 100.00 kW RPM kW 125.00 RPM kW 150.00 RPM kW 175.00 RPM 2.24 Nom kw Standard Motor & Low Static Drive Accessory kW 200.00 RPM kW 225.00 RPM kW 250.00 RPM kW 2.24 Nom kw Standard Motor Drive 7985 — — 429 0.62 463 0.71 496 0.81 529 0.92 562 1.03 592 1.14 622 1.26 652 1.39 679 8750 419 0.67 457 0.78 489 0.88 520 0.98 549 1.09 580 1.21 610 1.33 638 1.45 665 1.58 693 1.52 1.72 9515 449 0.84 485 0.96 516 1.07 545 1.18 572 1.29 599 1.41 628 1.54 656 1.68 682 1.81 707 1.94 10280 478 1.04 513 1.17 544 1.30 571 1.41 597 1.52 623 1.64 648 1.77 674 1.92 700 2.07 725 2.21 11045 508 1.26 542 1.40 572 1.55 598 1.67 623 1.79 647 1.92 671 2.05 694 2.19 718 2.34 743 2.50 2.24 Nom kw Standard Motor & High Static Drive Accessory Continued External Static Pressure (Pascals) 275.00 m3/h RPM kW 300.00 RPM kW 325.00 RPM 350.00 kW RPM kW 375.00 RPM kW 400.00 RPM kW 425.00 450.00 475.00 500.00 RPM kW RPM kW RPM kW RPM kW 2.24 Nom kw Standard Motor & High Static Drive Accessory 7985 705 1.65 731 1.79 756 1.94 780 2.09 803 2.23 826 2.37 848 2.52 870 2.66 890 2.81 910 2.95 8750 719 1.86 744 2.00 768 2.14 792 2.30 815 2.45 837 2.61 859 2.77 880 2.93 901 3.09 921 3.25 9515 732 2.08 758 2.23 782 2.39 805 2.54 827 2.70 849 2.86 870 3.03 891 3.20 912 3.37 932 3.55 10280 749 2.35 771 2.49 795 2.65 819 2.82 841 2.98 862 3.15 883 3.31 903 3.49 923 3.67 943 3.85 11045 767 2.66 789 2.81 811 2.96 832 3.12 854 3.29 876 3.46 897 3.64 917 3.82 937 4.00 956 4.18 3.73 Nom Oversized Motor & Drive 3.73 Nom Oversized Motor & High Static Drive Accessory Note: Data includes pressure drop for filters and wet coil. Table 23. Evaporator fan performance TS*175F downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 cfm .20 .30 .40 .50 .60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP .70 .80 .90 1.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3HP Standard Motor & Low Static Drive Accessory 3HP Standard Motor Drive 4700 — — 429 0.84 463 0.96 496 1.08 529 1.23 562 1.38 592 1.53 622 1.69 652 1.86 679 2.04 5150 419 0.90 457 1.05 489 1.18 520 1.31 549 1.46 580 1.62 610 1.79 638 1.95 665 2.12 693 2.30 5600 449 1.13 485 1.29 516 1.44 545 1.58 572 1.73 599 1.88 628 2.07 656 2.25 682 2.43 707 2.60 6050 478 1.39 513 1.56 544 1.74 571 1.89 597 2.04 623 2.20 648 2.38 674 2.57 700 2.77 725 2.96 6500 508 1.69 542 1.88 572 2.07 598 2.24 623 2.40 647 2.57 671 2.75 694 2.93 718 3.14 743 3.35 3HP Standard Motor & High Static Drive Accessory Continued External Static Pressure (Inches of Water) 1.10 cfm 1.20 1.30 1.40 1.50 1.60 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.70 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3HP Standard Motor & High Static Drive Accessory 4700 705 2.22 731 2.41 756 2.60 780 2.80 803 2.99 826 3.18 848 3.37 870 3.57 890 3.76 910 3.96 5150 719 2.49 744 2.68 768 2.88 792 3.08 815 3.29 837 3.51 859 3.72 880 3.93 901 4.14 921 4.35 5600 732 2.79 758 3.00 782 3.20 805 3.41 827 3.62 849 3.84 870 4.06 891 4.29 912 4.53 932 4.76 6050 749 3.15 771 3.34 795 3.56 819 3.78 841 4.00 862 4.22 883 4.44 903 4.68 923 4.92 943 5.16 6500 767 3.56 789 3.77 811 3.97 832 4.18 854 4.41 876 4.65 897 4.88 917 5.12 937 5.36 956 5.61 5HP Oversized Motor & Drive 5HP Oversized Motor & High Static Drive Accessory Note: Data includes pressure drop for filters and wet coil. RT-PRC034-EN 45 Performance Data Fan Performance Table 24. Evaporator fan performance TS*200F downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 m3/h RPM kW 50.00 RPM kW 75.00 RPM kW 100.00 RPM kW 125.00 RPM kW 2.24 Nom kw Standard Motor & Low Static Drive Accy 150.00 RPM kW 175.00 RPM kW 200.00 RPM kW 225.00 RPM 250.00 kW RPM kW 2.24 Nom kw Standard Motor & High Static Drive Accy 9005 429 0.72 466 0.84 498 0.94 528 1.04 557 1.15 586 1.27 616 1.40 644 1.53 670 1.65 697 1.78 9940 465 0.94 501 1.07 531 1.19 559 1.30 586 1.42 612 1.53 638 1.66 666 1.81 692 1.95 717 2.09 10875 502 1.21 536 1.35 565 1.49 592 1.61 617 1.73 642 1.86 665 1.98 689 2.12 714 2.28 739 2.43 11810 539 1.53 572 1.67 600 1.83 626 1.97 650 2.10 673 2.23 695 2.36 717 2.50 739 2.65 761 2.81 12745 575 1.87 607 2.05 635 2.21 660 2.37 683 2.52 704 2.66 726 2.80 747 2.95 767 3.10 787 3.25 2.24 Nom kw Standard Motor Drive 3.73 Nom kw Oversized Motor & Drive Continued External Static Pressure (Pascals) 275.00 m3/h RPM kW 300.00 RPM kW 325.00 RPM kW 350.00 RPM kW 375.00 RPM kW 400.00 RPM kW 425.00 450.00 475.00 500.00 RPM kW RPM kW RPM kW RPM kW 2.24 Nom kw Standard Motor & High Static Drive Accessory 9005 724 1.93 749 2.07 772 2.22 796 2.37 818 2.53 841 2.69 862 2.86 884 3.02 904 3.18 925 3.34 9940 741 2.22 765 2.37 790 2.53 813 2.69 835 2.85 856 3.01 877 3.18 898 3.36 918 3.53 938 3.71 10875 763 2.59 786 2.74 807 2.89 829 3.05 851 3.22 873 3.39 894 3.57 914 3.74 934 3.92 953 4.10 11810 784 2.98 807 3.15 829 3.32 850 3.48 870 3.64 889 3.81 910 3.99 931 4.18 — — — — 12745 808 3.42 829 3.60 850 3.78 871 3.96 892 4.14 — — — — — — — — — — 3.73 Nom kw Oversized Motor & Drive 3.73 Nom kw Oversized Motor & High Static Drive Accessory Note: Data includes pressure drop for filters and wet coil. Table 25. Evaporator fan performance TS*200F downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 cfm .20 .30 .40 .50 .60 .70 .80 .90 1.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3HP Standard Motor & Low Static Drive Accessory 3HP Standard Motor & High Static Drive Accessory 5300 429 0.97 466 1.13 498 1.26 528 1.40 557 1.54 586 1.70 616 1.88 644 2.05 670 2.21 697 2.39 5850 465 1.27 501 1.44 531 1.60 559 1.75 586 1.90 612 2.06 638 2.23 666 2.42 692 2.61 717 2.80 6400 502 1.62 536 1.81 565 2.00 592 2.16 617 2.32 642 2.49 665 2.66 689 2.85 714 3.05 739 3.26 6950 539 2.05 572 2.24 600 2.45 626 2.64 650 2.82 673 2.99 695 3.17 717 3.36 739 3.55 761 3.77 7500 575 2.51 607 2.74 635 2.97 660 3.18 683 3.38 704 3.57 726 3.76 747 3.95 767 4.16 787 4.36 3HP Standard Motor Drive 5HP Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 cfm 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3HP Standard Motor & High Static Drive Accessory 5300 724 2.59 749 2.78 772 2.98 796 3.18 818 3.40 841 3.61 862 3.83 884 4.05 904 4.27 925 4.48 5850 741 2.98 765 3.18 790 3.40 813 3.61 835 3.82 856 4.04 877 4.27 898 4.50 918 4.74 938 4.98 6400 763 3.47 786 3.67 807 3.87 829 4.08 851 4.31 873 4.55 894 4.78 914 5.01 934 5.26 953 5.50 6950 784 4.00 807 4.23 829 4.45 850 4.67 870 4.89 889 5.11 910 5.35 931 5.60 — — — — 7500 808 4.59 829 4.82 850 5.07 871 5.31 892 5.56 — — — — — — — — — — 5HP Oversized Motor & Drive 5HP Oversized Motor & High Static Drive Accessory Note: Data includes pressure drop for filters and wet coil. 46 RT-PRC034-EN Performance Data Fan Performance Table 26. Evaporator fan performance TS*250F downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 m3/h RPM kW 50.00 RPM kW 75.00 RPM 100.00 kW RPM kW 125.00 RPM kW 150.00 RPM 175.00 kW RPM 3.73 Nom kW Standard Motor & Low Static Drive Accessory kW 200.00 RPM kW 225.00 RPM kW 250.00 RPM kW 3.73 Nom kw Standard Motor and Drive 11380 521 1.37 556 1.52 584 1.67 610 1.80 635 1.93 658 2.05 681 2.19 704 2.32 727 2.47 751 2.63 12485 566 1.78 597 1.94 625 2.11 650 2.26 674 2.41 696 2.54 717 2.68 738 2.82 759 2.97 780 3.13 13590 610 2.26 639 2.43 667 2.61 691 2.79 714 2.96 735 3.11 755 3.26 775 3.41 795 3.56 814 3.72 14695 656 2.84 683 3.02 709 3.20 732 3.40 754 3.58 775 3.76 794 3.93 813 4.09 832 4.25 — — 15800 701 3.51 725 3.68 750 3.88 773 4.09 — — — — — — — — — — — — 3.73 Nom kw Standard Motor & High Static Drive Accessory (1) Continued External Static Pressure (Pascals) 275.00 m3/h RPM kW 300.00 RPM kW 325.00 RPM kW 350.00 RPM kW 375.00 RPM kW 400.00 RPM 425.00 kW RPM 450.00 475.00 kW RPM kW RPM kW 500.00 RPM kW 3.73 Nom kw Standard Motor & High Static Drive Accessory (1) 11380 774 2.80 797 2.96 819 3.12 839 3.27 860 3.44 882 3.61 903 3.79 924 3.98 943 4.16 — — 12485 801 3.29 823 3.47 844 3.65 865 3.83 886 4.01 905 4.18 — — — — — — — — 13590 833 3.88 852 4.06 871 4.24 — — — — — — — — — — — — — — 14695 — — — — — — — — — — — — — — — — — — — — 15800 — — — — — — — — — — — — — — — — — — — — 3.73 Nom kw Standard Motor & High Static Drive Accessory (2) Note: Data includes pressure drop for filters and wet coil. Table 27. Evaporator fan performance TS*250F downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 cfm .20 .30 .40 .50 .60 .70 .80 .90 1.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5HP Standard Motor & Low Static Drive Accessory 5HP Standard Motor and Drive 6700 521 1.84 556 2.04 584 2.23 610 2.42 635 2.58 658 2.75 681 2.93 704 3.11 727 3.31 751 3.53 7350 566 2.39 597 2.60 625 2.82 650 3.03 674 3.23 696 3.40 717 3.59 738 3.78 759 3.98 780 4.19 8000 610 3.03 639 3.26 667 3.50 691 3.74 714 3.97 735 4.17 755 4.37 775 4.57 795 4.78 814 4.99 8650 656 3.81 683 4.06 709 4.30 732 4.56 754 4.80 775 5.05 794 5.27 813 5.48 832 5.70 — — 9300 701 4.70 725 4.93 750 5.20 773 5.48 — — — — — — — — — — — — 5HP Standard Motor & High Static Drive Accessory (1) Continued External Static Pressure (Inches of Water) 1.10 cfm 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5HP Standard Motor & High Static Drive Accessory (1) 6700 774 3.75 797 3.97 819 4.18 839 4.39 860 4.61 882 4.84 903 5.09 924 5.33 943 5.58 — 7350 801 4.42 823 4.66 844 4.90 865 5.13 886 5.37 905 5.60 — — — — — — — — — 8000 833 5.21 852 5.44 871 5.69 — — — — — — — — — — — — — — 8650 — — — — — — — — — — — — — — — — — — — — 9300 — — — — — — — — — — — — — — — — — — — — 5HP Standard Motor & High Static Drive Accessory (2) Note: Data includes pressure drop for filters and wet coil. RT-PRC034-EN 47 Performance Data Fan Performance Table 28. Evaporator fan performance YS*155F downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 50.00 m3/h RPM kW RPM kW 75.00 RPM 100.00 kW RPM kW 125.00 RPM kW 150.00 RPM kW 1.49 Nom kW Standard Motor & Low Static Drive Accessory 175.00 RPM kW 200.00 RPM kW 225.00 RPM kW 250.00 RPM kW 1.49 Nom kw Standard Motor & High Static Drive Accessory 7140 — — 404 0.49 441 0.57 478 0.67 514 0.77 547 0.87 580 0.98 610 1.10 639 1.22 667 1.35 7820 391 0.52 429 0.61 463 0.69 496 0.79 530 0.90 563 1.01 593 1.12 624 1.24 652 1.37 679 1.49 8500 418 0.64 455 0.75 487 0.84 517 0.94 548 1.05 579 1.17 609 1.29 636 1.40 665 1.53 692 1.67 9180 446 0.79 481 0.91 511 1.01 540 1.11 568 1.22 596 1.34 626 1.47 653 1.60 679 1.73 705 1.86 9860 473 0.96 507 1.09 536 1.20 564 1.31 590 1.42 616 1.54 643 1.67 670 1.81 696 1.95 720 2.09 1.49 Nom kw Standard Motor Drive 2.24 Nom kw Oversized Motor & Drive Continued External Static Pressure (Pascals) 275.00 m3/h RPM kW 300.00 RPM kW 325.00 RPM 350.00 kW RPM kW 375.00 RPM kW 400.00 RPM kW 425.00 RPM 1.49 Nom kw Standard Motor & High Static Drive Accessory kW 450.00 RPM kW 475.00 RPM kW 500.00 RPM kW 2.24 Nom kw Oversized Motor & Drive 7140 694 1.48 721 1.60 746 1.73 770 1.86 793 1.99 816 2.12 837 2.25 859 2.38 — — — — 7820 705 1.63 731 1.77 756 1.91 780 2.05 803 2.19 826 2.33 848 2.47 — — — — — — 8500 718 1.80 743 1.95 767 2.09 790 2.24 813 2.40 836 2.55 — — — — — — — — 9180 732 2.01 756 2.15 779 2.30 802 2.45 — — — — — — — — — — — — 9860 744 2.22 769 2.38 793 2.53 — — — — — — — — — — — — — — Note: Data includes pressure drop for filters and wet coil. Table 29. Evaporator fan performance YS*155F downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 CFM .20 .30 .40 .50 .60 .70 .80 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2HP Standard Motor & Low Static Drive Accessory .90 RPM BHP 1.00 RPM BHP RPM BHP 2HP Standard Motor & High Static Drive Accessory 4200 — — 404 0.65 441 0.77 478 0.90 514 1.03 547 1.17 580 1.32 610 1.47 639 1.63 667 1.80 4600 391 0.69 429 0.81 463 0.93 496 1.06 530 1.21 563 1.36 593 1.50 624 1.67 652 1.83 679 2.00 5000 418 0.86 455 1.00 487 1.13 517 1.26 548 1.41 579 1.57 609 1.73 636 1.88 665 2.06 692 2.24 5400 446 1.06 481 1.22 511 1.35 540 1.49 568 1.63 596 1.80 626 1.97 653 2.15 679 2.31 705 2.49 5800 473 1.28 507 1.46 536 1.61 564 1.75 590 1.90 616 2.06 643 2.24 670 2.43 696 2.62 720 2.80 2HP Standard Motor Drive 3HP Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 CFM 1.20 1.30 1.40 1.50 1.60 1.70 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2HP Standard Motor & High Static Drive Accessory 1.80 RPM BHP 1.90 2.00 RPM BHP RPM BHP 3HP Oversized Motor & Drive 4200 694 1.98 721 2.15 746 2.32 770 2.49 793 2.67 816 2.84 837 3.02 859 3.20 — — — — 4600 705 2.18 731 2.37 756 2.56 780 2.75 803 2.94 826 3.12 848 3.31 — — — — — — 5000 718 2.42 743 2.61 767 2.81 790 3.01 813 3.22 836 3.42 — — — — — — — — 5400 732 2.69 756 2.88 779 3.08 802 3.29 — — — — — — — — — — — — 5800 744 2.98 769 3.19 793 3.40 — — — — — — — — — — — — — — Note: Data includes pressure drop for filters and wet coil. 48 RT-PRC034-EN Performance Data Fan Performance Table 30. Evaporator fan performance YS*175F downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 50.00 75.00 100.00 125.00 150.00 175.00 200.00 225.00 250.00 m3/h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 2.24 Nom kw Standard Motor & Low Static Drive Accy 2.24 Nom kw Standard Motor & High Static Drive Accy 7985 — — 442 0.66 476 0.75 508 0.85 542 0.96 574 1.07 603 1.19 634 1.31 662 1.44 689 8750 437 0.72 472 0.83 503 0.92 533 1.03 563 1.14 594 1.27 623 1.39 650 1.51 678 1.64 705 1.78 9515 469 0.91 502 1.02 532 1.13 560 1.24 587 1.35 615 1.48 643 1.61 671 1.75 696 1.88 720 2.01 10280 502 1.12 533 1.25 561 1.37 588 1.48 613 1.60 638 1.72 664 1.86 690 2.01 716 2.16 740 2.30 11045 533 1.36 564 1.51 591 1.64 616 1.76 640 1.88 664 2.01 688 2.15 711 2.30 736 2.46 760 2.61 2.24 Nom kw Standard Motor Drive 1.57 3.73 Nom kw Oversized Motor & Drive Continued External Static Pressure (Pascals) 275.00 300.00 325.00 350.00 375.00 400.00 425.00 450.00 475.00 500.00 m3/h RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW 2.24 Nom kw Standard Motor & High Static Drive Accessory 7985 715 1.71 741 1.85 765 1.99 789 2.14 812 2.28 835 2.43 856 2.57 877 2.72 898 2.86 918 3.01 8750 731 1.92 755 2.06 779 2.21 802 2.37 825 2.53 847 2.69 869 2.85 890 3.00 910 3.16 930 3.32 9515 746 2.16 771 2.32 794 2.47 817 2.62 839 2.78 860 2.95 882 3.12 902 3.30 923 3.47 943 3.64 10280 763 2.44 786 2.59 810 2.75 833 2.92 854 3.08 875 3.25 896 3.42 916 3.60 936 3.78 956 3.97 11045 783 2.77 805 2.92 826 3.07 848 3.24 870 3.42 892 3.59 912 3.77 931 3.95 951 4.13 — — 3.73 Nom kw Oversized Motor & Drive 3.73 Nom kw Oversized Motor & High Static Drive Accessory Note: Data includes pressure drop for filters and wet coil. Table 31. Evaporator fan performance YS*175F downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 CFM .20 .30 .40 .50 .60 .70 .80 .90 1.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3HP Standard Motor & Low Static Drive Accessory 3HP Standard Motor & High Static Drive Accessory 4700 — — 442 0.88 476 1.00 508 1.14 542 1.29 574 1.44 603 1.59 634 1.76 662 1.93 689 2.10 5150 437 0.97 472 1.11 503 1.24 533 1.38 563 1.53 594 1.70 623 1.86 650 2.02 678 2.20 705 2.39 5600 469 1.22 502 1.37 532 1.51 560 1.66 587 1.81 615 1.98 643 2.16 671 2.35 696 2.52 720 2.70 6050 502 1.50 533 1.68 561 1.83 588 1.99 613 2.14 638 2.31 664 2.50 690 2.70 716 2.89 740 3.08 6500 533 1.82 564 2.02 591 2.20 616 2.36 640 2.53 664 2.70 688 2.88 711 3.08 736 3.29 760 3.50 3HP Standard Motor Drive 5HP Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 CFM 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3HP Standard Motor & High Static Drive Accessory 4700 715 2.29 741 2.48 765 2.68 789 2.87 812 3.06 835 3.25 856 3.45 877 3.64 898 3.84 918 4.03 5150 731 2.58 755 2.77 779 2.97 802 3.18 825 3.39 847 3.60 869 3.82 890 4.03 910 4.24 930 4.45 5600 746 2.90 771 3.11 794 3.31 817 3.52 839 3.73 860 3.96 882 4.19 902 4.42 923 4.65 943 4.88 6050 763 3.27 786 3.48 810 3.69 833 3.91 854 4.14 875 4.36 896 4.59 916 4.83 936 5.07 956 5.32 6500 783 3.71 805 3.92 826 4.12 848 4.35 870 4.58 892 4.82 912 5.05 931 5.29 951 5.54 — — 5HP Oversized Motor & Drive 5HP Oversized Motor & High Static Drive Accessory Note: Data includes pressure drop for filters and wet coil. RT-PRC034-EN 49 Performance Data Fan Performance Table 32. Evaporator fan performance YS*200F downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 50.00 m3/h RPM kW RPM kW 75.00 RPM 100.00 kW RPM kW 125.00 RPM kW 2.24 Nom kw Standard Motor & Low Static Drive Accy 150.00 RPM kW 175.00 RPM kW 200.00 RPM kW 225.00 RPM kW 250.00 RPM kW 2.24 Nom kw Standard Motor & High Static Drive Accy 9005 448 0.78 482 0.89 513 0.99 542 1.09 571 1.21 601 1.33 630 1.46 657 1.59 683 1.71 710 1.86 9940 487 1.02 519 1.15 548 1.26 575 1.37 601 1.48 627 1.61 655 1.75 682 1.89 707 2.03 731 2.17 10875 527 1.31 557 1.45 584 1.58 610 1.69 634 1.82 658 1.95 682 2.08 707 2.23 732 2.39 756 2.54 11810 566 1.64 595 1.80 622 1.95 646 2.08 668 2.21 691 2.34 713 2.48 735 2.63 757 2.78 780 2.95 12745 607 2.05 634 2.21 659 2.37 682 2.52 704 2.66 725 2.80 746 2.94 767 3.09 787 3.25 807 3.41 2.24 Nom kw Standard Motor Drive 3.73 Nom kw Oversized Motor & Drive Continued External Static Pressure (Pascals) 275.00 300.00 m3/h RPM kW RPM kW 325.00 RPM 350.00 kW RPM kW 375.00 RPM kW 400.00 RPM 425.00 450.00 475.00 500.00 kW RPM kW RPM kW RPM kW RPM kW 2.24 Nom kw Standard Motor & High Static Drive Accessory 9005 736 2.00 760 2.15 784 2.29 807 2.45 829 2.61 851 2.77 873 2.94 894 3.10 914 3.26 934 3.42 9940 755 2.31 780 2.47 803 2.62 826 2.78 847 2.95 868 3.11 889 3.28 910 3.46 930 3.64 950 3.82 10875 779 2.69 800 2.84 822 3.00 845 3.17 867 3.34 888 3.51 908 3.69 928 3.87 947 4.05 966 4.23 11810 803 3.12 825 3.29 847 3.46 866 3.62 886 3.78 907 3.96 928 4.15 — — — — — — 12745 828 3.59 850 3.78 871 3.96 891 4.14 — — — — — — — — — — — — 3.73 Nom kw Oversized Motor & Drive 3.73 Nom kw Oversized Motor & High Static Drive Accessory Note: Data includes pressure drop for filters and wet coil. Table 33. Evaporator fan performance YS*200F downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 CFM .20 .30 .40 RPM BHP RPM BHP RPM BHP RPM BHP .50 .60 .70 .80 RPM BHP RPM BHP RPM BHP 3HP Standard Motor & Low Static Drive Accessory .90 1.00 RPM BHP RPM BHP RPM BHP 3HP Standard Motor & High Static Drive Accessory 5300 448 1.05 482 1.19 513 1.33 542 1.46 571 1.62 601 1.79 630 1.96 657 2.13 683 2.30 710 2.49 5850 487 1.37 519 1.54 548 1.68 575 1.83 601 1.99 627 2.16 655 2.35 682 2.54 707 2.72 731 2.91 6400 527 1.76 557 1.95 584 2.11 610 2.27 634 2.44 658 2.61 682 2.79 707 2.99 732 3.20 756 3.41 6950 566 2.20 595 2.41 622 2.62 646 2.79 668 2.96 691 3.14 713 3.33 735 3.52 757 3.73 780 3.96 7500 607 2.75 634 2.97 659 3.18 682 3.38 704 3.57 725 3.76 746 3.94 767 4.15 787 4.36 807 4.57 3HP Standard Motor Drive 5HP Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 CFM 1.20 1.30 1.40 RPM BHP RPM BHP RPM BHP RPM BHP 1.50 1.60 1.70 RPM BHP RPM BHP RPM BHP 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP 3HP Standard Motor & High Static Drive Accessory 5300 736 2.68 760 2.88 784 3.08 807 3.29 829 3.50 851 3.72 873 3.94 894 4.16 914 4.37 934 4.59 5850 755 3.10 780 3.31 803 3.52 826 3.73 847 3.95 868 4.17 889 4.40 910 4.64 930 4.88 950 5.12 6400 779 3.61 800 3.81 822 4.02 845 4.25 867 4.48 888 4.71 908 4.95 928 5.19 947 5.43 966 5.68 6950 803 4.19 825 4.41 847 4.63 866 4.85 886 5.07 907 5.31 928 5.56 — — — — — — 7500 828 4.82 850 5.06 871 5.31 891 5.55 — — — — — — — — — — — — 5HP Oversized Motor & Drive 5HP Oversized Motor & High Static Drive Accessory Note: Data includes pressure drop for filters and wet coil. 50 RT-PRC034-EN Performance Data Fan Performance Table 34. Evaporator fan performance YS*250F downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 50.00 m3/h RPM kW RPM kW 75.00 RPM 100.00 kW RPM kW 125.00 RPM kW 150.00 RPM 175.00 kW RPM 3.73 Nom kW Standard Motor & Low Static Drive Accessory kW 200.00 RPM kW 225.00 RPM kW 250.00 RPM kW 3.73 Nom kW Standard Motor and Drive 11380 548 1.48 578 1.64 604 1.77 629 1.90 653 2.02 676 2.15 699 2.29 721 2.44 745 2.60 769 2.76 12485 596 1.93 623 2.09 649 2.25 672 2.39 694 2.53 716 2.67 737 2.81 758 2.96 778 3.12 800 3.28 13590 641 2.44 670 2.64 693 2.80 716 2.97 737 3.12 757 3.27 777 3.42 797 3.58 816 3.74 835 3.90 14695 690 3.07 717 3.27 739 3.45 760 3.64 780 3.81 799 3.97 818 4.13 — — — — — — 15800 737 3.76 762 3.98 784 4.20 — — — — — — — — — — — — — — 3.73 Nom kW Standard Motor & High Static Drive Accessory (1) Continued External Static Pressure (Pascals) 275.00 300.00 m3/h RPM kW RPM kW 325.00 RPM kW 350.00 RPM kW 375.00 RPM kW 400.00 RPM 425.00 kW RPM 450.00 kW RPM kW 475.00 RPM kW 500.00 RPM kW 3.73 Nom kW Standard Motor & High Static Drive Accessory (1) 11380 792 2.92 814 3.08 835 3.24 855 3.40 877 3.57 898 3.75 919 3.93 939 4.12 — — — — 12485 821 3.46 843 3.64 864 3.82 885 3.99 904 4.17 — — — — — — — — — — 13590 853 4.07 873 4.26 — — — — — — — — — — — — — — — — 14695 — — — — — — — — — — — — — — — — — — — — 15800 — — — — — — — — — — — — — — — — — — — — 3.73 Nom kW Standard Motor & High Static Drive Accessory (2) Note: Data includes pressure drop for filters and wet coil. Table 35. Evaporator fan performance YS*250F downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 CFM .20 .30 .40 .50 .60 .70 .80 .90 1.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5HP Standard Motor & Low Static Drive Accessory 5HP Standard Motor and Drive 6700 548 1.98 578 2.19 604 2.37 629 2.54 653 2.71 676 2.89 699 3.07 721 3.27 745 3.48 769 3.70 7350 596 2.59 623 2.81 649 3.02 672 3.21 694 3.39 716 3.58 737 3.77 758 3.97 778 4.18 800 4.40 8000 641 3.27 670 3.54 693 3.76 716 3.99 737 4.19 757 4.39 777 4.59 797 4.80 816 5.02 835 5.24 8650 690 4.12 717 4.39 739 4.63 760 4.89 780 5.11 799 5.32 818 5.54 — — — — — — 9300 737 5.04 762 5.34 784 5.63 — — — — — — — — — — — — — — 5HP Standard Motor & High Static Drive Accessory (1) Continued External Static Pressure (Inches of Water) 1.10 CFM 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5HP Standard Motor & High Static Drive Accessory (1) 6700 792 3.92 814 4.13 835 4.34 855 4.55 877 4.79 898 5.03 919 5.28 939 5.52 — — — 7350 821 4.64 843 4.88 864 5.12 885 5.36 904 5.59 — — — — — — — — — — — 8000 853 5.46 873 5.72 — — — — — — — — — — — — — — — — 8650 — — — — — — — — — — — — — — — — — — — — 9300 — — — — — — — — — — — — — — — — — — — — 5HP Standard Motor & High Static Drive Accessory (2) Note: Data includes pressure drop for filters and wet coil. RT-PRC034-EN 51 Performance Data Fan Performance Table 36. Evaporator fan performance WS*155E downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 50.00 m3/h RPM kW RPM kW 75.00 RPM 100.00 kW RPM kW 125.00 RPM kW 150.00 RPM 1.49 Nom kW Standard Motor & Low Static Drive Accessory kW 175.00 RPM kW 200.00 RPM kW 225.00 RPM 250.00 kW RPM kW 1.49 Nom kW Standard Motor & High Static Drive Accessory 6800 346 0.35 388 0.43 426 0.51 465 0.60 502 0.70 537 0.80 570 0.91 601 1.02 631 1.14 660 1.27 7650 377 0.47 417 0.56 452 0.65 486 0.74 521 0.85 554 0.96 585 1.07 617 1.19 646 1.31 673 1.44 8500 409 0.62 448 0.73 480 0.82 512 0.92 542 1.03 574 1.15 604 1.27 632 1.38 661 1.51 689 1.65 9350 442 0.80 479 0.92 510 1.03 539 1.13 567 1.24 595 1.36 624 1.49 652 1.63 678 1.76 703 1.89 10200 475 1.01 510 1.14 541 1.27 568 1.38 594 1.50 620 1.62 645 1.74 672 1.89 698 2.04 723 2.18 1.49 Nom kW Standard Motor Drive 2.24 Nom kW Oversized Motor & Drive Continued External Static Pressure (Pascals) 275.00 300.00 m3/h RPM kW RPM kW 325.00 RPM kW 350.00 RPM kW 375.00 RPM kW 400.00 RPM kW 425.00 RPM 450.00 kW RPM kW 475.00 RPM 500.00 kW RPM kW 1.49 Nom kW Standard Motor & High Static Drive Accessory 6800 687 1.39 714 1.51 739 1.64 763 1.76 787 1.88 809 2.01 831 2.14 851 2.27 — — — — 7650 700 1.57 726 1.71 751 1.85 775 1.99 799 2.13 821 2.27 843 2.40 — — — — — — 8500 714 1.78 739 1.93 764 2.07 788 2.22 811 2.38 833 2.54 — — — — — — — — 9350 730 2.03 755 2.18 779 2.33 802 2.48 — — — — — — — — — — — — 10200 747 2.32 770 2.46 — — — — — — — — — — — — — — — — 2.24 Nom kw Oversized Motor & Drive Notes: 1. Data includes pressure drop for filters and wet coil. 2. For 200 volt, use 50 Hz reference Performance Data Table and Standard Motor & Sheave/Fan Speed (RPM) to determine applicable operating range. Table 37. Evaporator fan performance WS*155E downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 CFM .20 .30 .40 .50 .60 .70 .80 .90 1.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2HP Standard Motor & Low Static Drive Accessory 2HP Standard Motor & High Static Drive Accessory 4000 346 0.47 388 0.57 426 0.68 465 0.81 502 0.94 537 1.07 570 1.22 601 1.37 631 1.53 660 1.70 4500 377 0.63 417 0.75 452 0.87 486 1.00 521 1.14 554 1.29 585 1.43 617 1.60 646 1.76 673 1.93 5000 409 0.83 448 0.98 480 1.10 512 1.23 542 1.38 574 1.54 604 1.70 632 1.86 661 2.03 689 2.21 5500 442 1.07 479 1.23 510 1.38 539 1.51 567 1.66 595 1.82 624 2.00 652 2.18 678 2.36 703 2.53 6000 475 1.36 510 1.53 541 1.70 568 1.85 594 2.01 620 2.17 645 2.34 672 2.53 698 2.73 723 2.92 2HP Standard Motor Drive 3HP Oversized Motor & Drive Continued External Static Pressure (Inches of Water) 1.10 CFM 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2HP Standard Motor & High Static Drive Accessory 3HP Oversized Motor & Drive 4000 687 1.86 714 2.03 739 2.19 763 2.36 787 2.53 809 2.70 831 2.87 851 3.05 — — — — 4500 700 2.11 726 2.30 751 2.48 775 2.67 799 2.85 821 3.04 843 3.22 — — — — — — 5000 714 2.39 739 2.58 764 2.78 788 2.98 811 3.19 833 3.40 — — — — — — — — 5500 730 2.72 755 2.92 779 3.12 802 3.33 — — — — — — — — — — — — 6000 747 3.11 770 3.30 — — — — — — — — — — — — — — — — Notes: 1. Data includes pressure drop for filters and wet coil. 2. For 200 volt, use 50 Hz reference Performance Data Table and Standard Motor & Sheave/Fan Speed (RPM) to determine applicable operating range. 52 RT-PRC034-EN Performance Data Fan Performance Table 38. Evaporator fan performance WS*200E downflow or horizontal (SI) External Static Pressure (Pascals) 25.00 50.00 m3/h RPM kW RPM kW 75.00 RPM 100.00 kW RPM 125.00 kW 2.24 Nom kW Standard Motor Drive RPM kW 150.00 RPM kW 175.00 RPM kW 200.00 RPM kW 225.00 RPM kW 250.00 RPM kW 2.24 Nom kw Standard Motor Drive & High Static Drive Accessory 8970 — — — — 446 0.80 475 0.91 504 1.03 533 1.15 561 1.28 588 1.42 613 1.56 636 1.69 10090 — — 449 0.94 481 1.05 510 1.18 536 1.31 561 1.44 587 1.58 611 1.72 636 1.87 660 2.03 11210 451 1.10 486 1.25 517 1.38 545 1.51 570 1.65 593 1.80 616 1.95 639 2.10 661 2.25 684 2.41 12330 491 1.45 525 1.62 554 1.77 581 1.91 605 2.06 628 2.21 649 2.38 670 2.54 691 2.71 711 2.87 13450 531 1.86 563 2.06 592 2.24 617 2.39 641 2.54 663 2.70 684 2.88 704 3.06 723 3.24 742 3.42 3.73 Nom kw Oversized Motor & Low Static Drive Accessory Continued External Static Pressure (Pascals) 275.00 300.00 m3/h RPM kW RPM kW 325.00 RPM kW 350.00 RPM kW 375.00 RPM kW 400.00 RPM kW 2.24 Nom kw Standard Motor & High Static Drive Accessory 425.00 RPM kW 450.00 RPM kW 475.00 RPM kW 500.00 RPM kW 3.73 Nom kw Oversized Motor & Drive 8970 657 1.83 678 1.97 699 2.11 721 2.26 742 2.41 762 2.57 782 2.72 801 2.87 820 3.03 837 3.18 10090 683 2.18 704 2.34 724 2.49 743 2.65 762 2.81 780 2.97 799 3.13 817 3.30 836 3.47 854 3.65 11210 706 2.57 728 2.75 749 2.92 769 3.10 787 3.27 805 3.44 822 3.62 839 3.79 856 3.97 872 4.15 12330 731 3.04 751 3.22 772 3.40 792 3.59 811 3.78 830 3.97 848 4.17 — — — — — — 13450 760 3.60 779 3.78 798 3.96 816 4.15 — — — — — — — — — — — — 3.73 Nom kw Oversized Motor & Low Static Drive Accessory Notes: 1. Data includes pressure drop for filters and wet coil. 2. For 200 volt, use 50 Hz reference Performance Data Table and Standard Motor & Sheave/Fan Speed (RPM) to determine applicable operating range. Table 39. Evaporator fan performance WS*200E downflow or horizontal (IP) External Static Pressure (Inches of Water) .10 CFM .20 .30 .40 .50 .60 .70 .80 .90 1.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3HP Standard Motor Drive 3HP Standard Motor Drive & High Static Drive Accessory 5200 — — — — 446 1.07 475 1.22 504 1.38 533 1.54 561 1.72 588 1.90 613 2.09 636 2.27 5900 — — 449 1.26 481 1.41 510 1.58 536 1.76 561 1.94 587 2.12 611 2.31 636 2.51 660 2.72 6600 451 1.47 486 1.67 517 1.85 545 2.02 570 2.21 593 2.41 616 2.61 639 2.81 661 3.02 684 3.23 7300 491 1.95 525 2.17 554 2.38 581 2.56 605 2.76 628 2.97 649 3.19 670 3.41 691 3.63 711 3.85 8000 531 2.50 563 2.77 592 3.00 617 3.21 641 3.41 663 3.62 684 3.86 704 4.10 723 4.34 742 4.58 5HP Oversized Motor & Low Static Drive Accessory Continued External Static Pressure (Inches of Water) 1.10 CFM 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3HP Standard Motor & High Static Drive Accessory 5HP Oversized Motor & Drive 5200 657 2.45 678 2.64 699 2.84 721 3.03 742 3.24 762 3.44 782 3.65 801 3.85 820 4.06 837 4.26 5900 683 2.93 704 3.14 724 3.34 743 3.55 762 3.76 780 3.98 799 4.20 817 4.43 836 4.66 854 4.89 6600 706 3.45 728 3.68 749 3.92 769 4.15 787 4.38 805 4.62 822 4.85 839 5.09 856 5.32 872 5.57 7300 731 4.08 751 4.31 772 4.56 792 4.81 811 5.07 830 5.33 848 5.59 — — — — — — 8000 760 4.82 779 5.07 798 5.32 816 5.57 — — — — — — — — — — — — 5HP Oversized Motor & Low Static Drive Accessory Notes: 1. Data includes pressure drop for filters and wet coil. 2. For 200 volt, use 50 Hz reference Performance Data Table and Standard Motor & Sheave/Fan Speed (RPM) to determine applicable operating range. RT-PRC034-EN 53 Performance Data Fan Speeds Table 40. T/YS*155–250 standard motor and drive/fan speed (rpm) Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1Turns Model No. Open Open Open Open Open Open T/YS*155F 466 501 535 570 604 639 N/A T/YS*175F 500 537 574 611 648 685 N/A T/YS*200F 500 537 574 611 648 685 N/A T/YS*250F 587 619 651 682 714 746 N/A Closed Notes: 1. * indicates both horizontal and downflow units 2. Factory set at 3 turns open. Table 41. T/YS*155–250 standard motor and low static fan drive Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1Turns Model No. Open Open Open Open Open Open T/YS*155F 376 404 432 460 488 516 N/A T/YS*175F 418 442 466 489 513 537 N/A T/YS*200F 418 442 466 489 513 537 N/A T/YS*250F 492 524 556 587 619 651 N/A Closed Note: * indicates both horizontal and downflow units Table 42. T/YS*155–250 standard motor and high static drive accessory/fan speed (rpm) Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1Turns Model No. Open Open Open Open Open Open T/YS*155F 600 628 656 683 711 739 N/A T/YS*175F 685 722 759 796 833 870 N/A T/YS*200F 685 722 759 796 833 870 N/A T/YS*250F 702 740 778 815 853 891 N/A Closed Note: * indicates both horizontal and downflow units Table 43. T/YS*155–250 oversized motor and drive/fan speed (rpm) Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1Turns Model No. Open Open Open Open Open Open T/YS*155F 621 667 713 758 804 850 N/A T/YS*175F 682 714 746 777 809 841 N/A T/YS*200F 682 714 746 777 809 841 N/A T/YS*250F 702 740 778 815 853 891 N/A Closed Note: * indicates both horizontal and downflow units 54 RT-PRC034-EN Performance Data Fan Speeds \ Table 44. WS*155, 200 standard motor and drive/fan speed (rpm) Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1Turns Model No. Open Open Open Open Open Open WS*155ED, ET 416 447 478 509 540 571 N/A WS*200ED, ET 574 611 648 685 722 759 N/A Closed Note: * indicates both horizontal and downflow units Table 45. WS*155, 200 standard motor and low static fan drive Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1Turns Model No. Open Open Open Open Open Open Closed WS*155ED 316 339 363 386 410 433 N/A WS*200ED 418 449 480 512 543 574 N/A Note: * indicates both horizontal and downflow units Table 46. WS*155, 200 standard motor and high static drive accessory/fan speed (rpm) Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1Turns Model No. Open Open Open Open Open Open WS*155ED 571 602 633 663 694 725 N/A WS*200ED 574 611 648 685 722 759 N/A Closed Note: * indicates both horizontal and downflow units Table 47. WS*155, 200 oversized motor and drive/fan speed (rpm) Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1Turns Model No. Open Open Open Open Open Open WS*155ED 621 667 698 728 759 850 N/A WS*200ED 702 740 777 814 851 891 N/A Closed Note: * indicates both horizontal and downflow units RT-PRC034-EN 55 Performance Data Static Pressure Drop Table 48. T/YS*155–250—static pressure drops through accessories—pascals Economizer with OA/RA Dampers(a) Electric Heater - Nom kW(b) Unit Model No. Airflow m3/h Standard Filters 100% OA 100% RA 5-12 14-27 33-41 D155 7140 6 8 5 7 9 10 — D155 8500 9 11 7 9 12 15 — D155 9860 12 15 10 12 16 20 — H155 7140 6 8 5 7 9 10 — H155 8500 9 11 7 9 12 15 — H155 9860 12 15 10 12 16 20 — D175 7985 7 10 7 8 10 13 — D175 9515 11 14 9 12 15 18 — D175 11045 14 18 12 16 20 24 — H175 7985 7 10 7 8 10 13 — H175 9515 11 14 9 12 15 18 — H175 11045 14 18 12 16 20 24 — D200 9005 12 29 6 — 11 14 16 D200 10875 18 42 9 — 16 21 23 D200 12745 24 57 13 — 22 29 31 H200 9005 10 33 6 — 11 14 16 H200 10875 15 48 9 — 16 21 23 H200 12745 21 66 13 — 22 29 31 D250 11380 20 46 9 — 17 22 25 D250 13590 28 66 13 — 24 31 36 D250 15800 38 89 18 — 33 42 49 H250 11380 16 52 9 — 17 22 25 H250 13590 23 75 13 — 24 31 36 H250 15800 31 101 18 — 33 42 49 45-54 (a) OA = Outside Air, RA = Return Air (b) Nominal kW ratings are at 415 V. Not all Heater sizes may be available. * Indicates both horizontal and downflow units. 56 RT-PRC034-EN Performance Data Static Pressure Drop Table 49. T/YS*155–250—static pressure drops through accessories—(inches water column) Economizer with OA/RA Dampers(a) Electric Heater - Nom kW(b) Unit Model No. Airflow CFM Standard Filters 100% OA 100% RA 5-12 14-27 33-41 45-54 D155 4200 0.02 0.03 0.02 0.03 0.03 0.04 — D155 5000 0.04 0.05 0.03 0.04 0.05 0.06 — D155 5800 0.05 0.06 0.04 0.05 0.07 0.08 — H155 4200 0.02 0.03 0.02 0.03 0.03 0.04 — H155 5000 0.04 0.05 0.03 0.04 0.05 0.06 — H155 5800 0.05 0.06 0.04 0.05 0.07 0.08 — D175 4700 0.03 0.04 0.03 0.03 0.04 0.05 — D175 5600 0.04 0.06 0.04 0.05 0.06 0.07 — D175 6500 0.06 0.07 0.05 0.06 0.08 0.10 — H175 4700 0.03 0.04 0.03 0.03 0.04 0.05 — H175 5600 0.04 0.06 0.04 0.05 0.06 0.07 — H175 6500 0.06 0.07 0.05 0.06 0.08 0.10 — D200 5300 0.05 0.11 0.03 — 0.04 0.06 0.06 D200 6400 0.07 0.17 0.04 — 0.06 0.08 0.09 D200 7500 0.10 0.23 0.05 — 0.09 0.11 0.13 H200 5300 0.04 0.13 0.03 — 0.04 0.06 0.06 H200 6400 0.06 0.19 0.04 — 0.06 0.08 0.09 H200 7500 0.08 0.26 0.05 — 0.09 0.11 0.13 D250 6700 0.08 0.19 0.04 — 0.07 0.09 0.10 D250 8000 0.11 0.27 0.05 — 0.10 0.12 0.15 D250 9300 0.15 0.36 0.07 — 0.13 0.17 0.20 H250 6700 0.06 0.21 0.04 — 0.07 0.09 0.10 H250 8000 0.09 0.30 0.05 — 0.10 0.12 0.15 H250 9300 0.13 0.40 0.07 — 0.13 0.17 0.20 (a) OA = Outside Air, RA = Return Air (b) Nominal kW ratings are at 415 V. Not all Heater sizes may be available. * Indicates both horizontal and downflow units. RT-PRC034-EN 57 Performance Data Static Pressure Drop Table 50. WS*155, 200—static pressure drops through accessories—pascals Economizer with OA/RA Dampers(a) Electric Heater - Nom kW(b) Unit Model No. Airflow m3/h Standard Filters 100% OA 100% RA 5-14 16-27 33-41 45-54 D155 6800 6 45 5 7 7 10 — D155 8500 8 62 5 10 12 15 — D155 10200 11 87 7 17 20 22 — H155 6800 6 45 5 7 7 10 — — H155 8500 8 62 5 10 12 15 H155 10200 11 87 7 17 20 22 — D200 8970 8 37 5 — 10 12 15 D200 11210 14 57 7 — 17 20 22 D200 13450 19 77 12 — 25 27 35 H200 8970 8 50 7 — 12 15 17 H200 11210 15 75 10 — 22 27 32 H200 13450 24 124 17 — 37 42 52 (a) OA = Outside Air, RA = Return Ai (b) Nominal kW ratings are at a 415 V * Indicates both horizontal and downflow units. Table 51. WS*155, 200—static pressure drops through accessories—(inches water column) Economizer with OA/RA Dampers(a) Electric Heater - Nom kW(b) Unit Model No. Airflow CFM Standard Filters 100% OA 100% RA 5-14 16-27 33-41 45-54 D155 4000 0.02 0.18 0.02 0.03 0.03 0.04 — D155 5000 0.03 0.25 0.02 0.04 0.05 0.06 — D155 6000 0.05 0.35 0.03 0.07 0.08 0.09 — H155 4000 0.02 0.18 0.02 0.03 0.03 0.04 — H155 5000 0.03 0.25 0.02 0.04 0.05 0.06 — H155 6000 0.05 0.35 0.03 0.07 0.08 0.09 — D200 5200 0.03 0.15 0.02 — 0.04 0.05 0.06 D200 6600 0.05 0.23 0.03 — 0.07 0.08 0.09 D200 8000 0.07 0.31 0.05 — 0.10 0.11 0.14 H200 5200 0.03 0.20 0.03 — 0.05 0.06 0.07 H200 6600 0.06 0.30 0.04 — 0.09 0.11 0.13 H200 8000 0.10 0.50 0.07 — 0.15 0.17 0.21 (a) OA = Outside Air, RA = Return Ai (b) Nominal kW ratings are at a 415 V * Indicates both horizontal and downflow units. 58 RT-PRC034-EN Controls ReliaTel Controlled Units Note: Zone sensor required for units configured for Single Zone VAV indoor fan system control to enable Single Zone VAV functionality. Zone Sensors are the building occupant’s comfort control devices. They replace the conventional electro-mechanical thermostats. The following zone sensor options are available for Voyager units: Differential Enthalpy Differential Enthalphy Replaces the standard dry bulb control with two enthalpy sensors that compare total heat content of the indoor air and outdoor air to determine the most efficient air source. This control option offers the highest level of comfort control, plus energy efficiency, available. Differential Pressure Switches This factory or field-installed option allows individual fan failure and dirty filter indication. The fan failure switch will disable all unit functions and “flash” the Service LED on the zone sensor. The dirty filter switch will light the Service LED on the zone sensor and will allow continued unit operation. Manual Changeover Manual/Automatic Changeover Manual/Automatic Changeover Heat, Cool or Off System Switch. Fan Auto or Off Switch. One temperature setpoint lever. Auto, Heat, Cool or Off System Switch. Fan Auto or Off Switch. Two temperature setpoint levers. Auto, Heat, Cool or Off System Switch. Fan Auto or Off Switch. Two temperature setpoint levers. Status Indication LED lights, System On, Heat, Cool, or Service. RA Remote Sensor & Room Remote Sensor The RA Remote Sensor is a Return Air Remote Sensor which can be mounted in the return air duct to report return air temperature. The Room Remote Sensor is a Space Remote Sensor which can be mounted on the wall to report/control from a remote location in the space. Wireless Zone Sensor LCD display that provides heat, cool, auto, or off. Includes two temperature setpoints and a lockable setting with °F or °C indicators. RT-PRC034-EN 59 Controls 60 Manual/Automatic Changeover Remote Sensor Integrated Comfort™ System Auto, Heat, Cool or Off System Switch. Fan Auto or Off Switch. Two temperature setpoint levers. Sensor(s) available for all zone sensors to provide remote sensing capabilities. Sensor(s) available with optional temperature adjustment and override buttons to provide central control through a Trane Integrated Comfort™ system. Programmable Night Setback CO2 Sensing Humidity Sensor Auto or manual changeover with seven-day programming. Keyboard selection of Heat, Cool, Fan, Auto, or On. All programmable sensors have System On, Heat, Cool, Service LED/indicators as standard. Night Setback Sensors have one (1) Occupied, one (1) Unoccupied, and one (1) Override program per day. The CO2 sensor shall have the ability to monitor space occupancy levels within the building by measuring the parts per million of CO2 (Carbon Dioxide) in the air. As the CO2 levels increase, the outside air damper modulates to meet the CO2 space ventilation requirements. The CO2 accessory shall be available as field installed. Field installed, wall-mounted or duct-mounted humidity sensor is used to control activation of the hot gas reheat dehumidification option. The humidity sensor can be set for humidity levels between 40 percent and 60 percent relative humidity by adjusting the ReliaTel Options Module. RT-PRC034-EN Controls Digital Display Programmable Thermostat with BuiltIn Relative Humidity Sensing (3H/2C) Digital Display Programmable Thermostat (3H/2C) Touchscreen Programmable Thermostat (2H/2C) Tue MON TUE WED THU FRI SAT FAN ON AUTO CIRC Three Heat/Two Cool digital display thermostat with builtin humidity control and display. This thermostat combines both humidity and dry bulb into one. Fully programmable with night setback. Two Heat/Two Cool auto changeover digital display thermostat. Seven-day programmable stat with night setback shall be available. SUN HEAT SYSTEM EM HEAT HEAT OFF COOL AUTO RESET DONE EDIT CANCEL PERIOD DEHUMIDIFIER COOL PM WAKE LEAVE RETURN SLEEP CANCEL Two Heat/Two Cool programmable thermostat with touch screen digital display. Menu-driven programming. Effortless setup. Program each day separately with no need to copy multiple days. All programming can be done on one screen. Easy to read and use. Large, clear backlit digital display. Digital Display Thermostat (3H/2C) Three Heat, Two Cool auto changeover digital display thermostat. Remote Potentiometer Minimum position setting of economizer can be remotely adjusted with this accessory. Trane Communication Interface (TCI) This factory or field-installed micro-processor interface allows the unit to communicate to Trane’s Integrated Comfort™ system.Economizer Controls The standard equipment offering is a fixed dry bulb changeover control. In addition, there are two optional controls, Enthalpy and Differential Enthalpy Control. Enthalpy Control Replaces the dry bulb control with a wet bulb changeover controller which has a fully adjustable setpoint. Enthalpy control offers a higher level of comfort control, along with energy savings potential, than the standard dry bulb control. This is due to the additional wet bulb sensing capability. RT-PRC034-EN 61 Electrical Data Table 52. TS* auxiliary electric heat capacity No. of Stages Stage 1 heater kW(1) Stage 2 heater kW(1) 2 13.4 13.4 26.9 2 13.4 13.4 40.3 2 26.9 13.4 26.9 2 13.4 13.4 40.3 2 26.9 13.4 53.8 2 26.9 26.9 Unit Model No. Total heater kW(1)(2) TS*155FD 26.9 TS*175FD TS*200FD TS*250FD Notes: 1. Heaters are rated at 415 V. For other than rated voltage, apply the following formula - kW = (Required Voltage/415)2 x Rated kW. 2. Not all Heater Models are available. 3. To calculate temperature rise across the electric heat use the following formulas: Temp Rise Across Electric Heater - °C = 2982 * Heater Capacity (kW)/Airflow (m3/h) Temp Rise Across Electric Heater - °F = 3160 * Heater Capacity (kW)/Airflow (cfm) Table 53. TS* electric heater voltage correction factors (apply to auxiliary electric heat capacity) Nominal Voltage Distribution Voltage Capacity Multiplier 380 0.84 415 400 0.93 415 1.00 Table 54. TS* unit wiring Unit Model Voltage Standard Indoor Fan Motor—MCA Oversize Indoor Fan Motor—MCA TS*155FD 380–415 41.0 44.0 TS*175FD 380–415 51.0 54.0 TS*200FD 380–415 56.0 59.0 TS*250FD 380–415 65.0 — Table 55. TS* unit wiring with electric heat (single point connection) Unit Model to Use With Heater kW Rating Unit Supply Power Control Stages Standard Indoor Oversized Motor Motor MCA MCA TS*155ED 11.3–13.5 380–415/50/3 1 41/41 44/44 TS*155FD 22.6–26.9 380–415/50/3 2 49/53 53/57 TS*155FD 33.8–40.4 380–415/50/3 2 71/77 74/80 TS*175FD 22.6–26.9 380–415/50/3 2 53/57 57/61 TS*175FD 33.8–40.4 380–415/50/3 2 74/80 79/84 TS*200FD 22.6–26.9 380–415/50/3 2 56/57 59/61 TS*200FD 33.8–40.4 380–415/50/3 2 74/80 79/84 TS*200FD 45.1–53.8 380–415/50/3 2 96/104 100/108 TS*250FD 22.6–26.9 380–415/50/3 2 65/65 — TS*250FD 33.8–40.4 380–415/50/3 2 79/84 — TS*250FD 45.1–53.8 380–415/50/3 2 100/108 — Note: * All units to be installed under local codes. 62 RT-PRC034-EN Electrical Data Table 56. TS* electric characteristics—evaporator fan motor—50 cycle Standard Evaporator Motor Model No. Motors Volts Ph Watts FLA Oversize Evaporator Motor Service No. LRA Factor Motors Volts Ph Watts FLA LRA Service Factor TS*155FD 1 380–415 3 1500 4.6 36.4 1.15 1 380–415 3 2200 6.5 57 1.15 TS*175FD 1 380–415 3 2200 6.5 57.0 1.15 1 380–415 3 3700 7.4 71.9 1.15 TS*200FD 1 380–415 3 2200 6.5 57.0 1.15 1 380–415 3 3700 7.0 65.1 1.15 TS*250FD 1 380–415 3 3700 7.4 71.9 1.15 — — — — — — — Table 57. TS* electric characteristics—compressor motor and condenser motor—50 cycle Compressor Motors Condenser Fan Motors Amps(a) Ampsa Unit Model No. No. Volts Ph Watts rpm RLA LRA No. Ph Watts FLA LRA TS*155FD 2 380–415/50 3 /4610 2900 17 142 2 1 300 1.6 3.8 TS*175FD 2 380–415/50 3 /4460 2900 21.4 142 2 1 560 2.5 5.8 TS*200FD 2 380–415/50 3 2900 22.1 147 2 1 560 2.5 5.8 TS*250FD 2 380–415/50 3 2900 21.4 142 2 1 665 2.5 5.8 (a) For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. *Indicates both downflow and horizontal units. Table 58. YS* unit wiring Unit Model Voltage YS*155FD 380–415 Standard Indoor Fan Motor—MCA Oversize Indoor Fan Motor—MCA 41.0 44.0 YS*175FD 380–415 51.0 54.0 YS*200FD 380–415 56.0 59.0 YS*250FD 380–415 65.0 — Table 59. YS* electric characteristics—evaporator fan motor—50 cycle Standard Evaporator Motor Model No. Motors Volts Ph Watts FLA Oversize Evaporator Motor Service No. LRA Factor Motors Volts Ph Watts FLA LRA Service Factor YS*155FD 1 380–415 3 1500 4.6 36.4 1.15 1 380/415 3 2200 6.5 57 1.15 YS*175FD 1 380–415 3 2200 6.5 57.0 1.15 1 380/415 3 3700 7.4 71.9 1.15 YS*200FD 1 380–415 3 2200 6.5 57.0 1.15 1 380/415 3 3700 7.0 65.1 1.15 YS*250FD 1 380–415 3 3700 7.4 71.9 1.15 — — — — — — — Table 60. YS* electric characteristics—compressor motor and condenser motor—50 cycle Compressor Motors Condenser Fan Motors Amps(a) Ampsa Unit Model No. No. Volts Ph Watts rpm RLA LRA No. Ph Watts FLA LRA YS*155FD 2 380–415/50 3 /4610 2900 17 142 2 1 300 1.6 3.8 YS*175FD 2 380–415/50 3 /4460 2900 21.4 142 2 1 560 2.5 5.8 YS*200FD 2 380–415/50 3 2900 22.1 147 2 1 560 2.5 5.8 YS*250FD 2 380–415/50 3 2900 21.4 142 2 1 665 2.5 5.8 (a) For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. *Indicates both downflow and horizontal units. RT-PRC034-EN 63 Electrical Data Table 61. YS* electrical characteristics—combustion blower motor Model Heat Heating Stages Watts RPM Volts Phase FLA YS*155FD Low 2 75 3500/3000 230 1 0.8 2.0 YS*155FD High 2 75 3500/3000 230 1 0.6 1.5 YS*175FD Low 2 75 3500/3000 230 1 0.8 2.0 YS*175FD High 2 75 3500/3000 230 1 0.6 1.5 YS*200FD Low 2 75 3500/3000 230 1 0.8 2.0 YS*200FD High 2 75 3500/3000 230 1 0.6 1.5 YS*250FD Low 2 75 3500/3000 230 1 0.8 2.0 YS*250FD High 2 75 3500/3000 230 1 0.6 1.5 LRA Table 62. WS* auxiliary electric heat capacity Total heater kW(1)(2) Unit Model No. Stage 1 Stage 2 heater kW(1) heater kW(1) No. of Stages WS*155ED 40.3 2 26.9 13.4 WS*155ET 37.5 2 25.0 12.5 26.9 2 13.4 13.4 40.3 2 26.9 13.4 53.8 2 26.9 26.9 25.0 1 25.0 — 37.5 2 25.0 12.5 50.0 2 25.0 25.0 WS*200ED WS*200ET Notes: 1. Heaters are rated at 415 V. For other than rated voltage, apply the following formula - kW = (Required Voltage/415)2 x Rated kW. 2. Not all Heater Models are available. 3. To calculate temperature rise across the electric heat use the following formulas: Temp Rise Across Electric Heater - °C = 2982 * Heater Capacity (kW)/Airflow (m3/h) Temp Rise Across Electric Heater - °F = 3160 * Heater Capacity (kW)/Airflow (cfm) Table 63. WS* electric heater voltage correction factors (apply to auxiliary electric heat capacity) Nominal Voltage Distribution Voltage Capacity Multiplier 200 200 1.00 380 0.84 400 0.93 415 1.00 415 Table 64. WS* unit wiring MCA 64 Standard Indoor Fan Motor—MCA Oversize Indoor Fan Motor—MCA 43.0 Unit Model Voltage WS*155ED 380–415/50/3 40.0 WS*155ET 200/50/3 83.0 — WS*200ED 380–415/50/3 59.0 62.0 WS*200ET 200/50/3 115.0 — RT-PRC034-EN Electrical Data Table 65. WS* unit wiring with electric heat (single point connection) MCA Models Heater kW Rating Unit Supply Power Control Stages Standard Indoor Motor MCA Oversized Motor MCA 22.6–26.9 380–415/50/3 1 60–63 64–66 33.8–40.4 380–415/50/3 2 83–87 86–90 45.1–53.8 380–415/50/3 2 104–110 107–113 12.5 200/50/3 1 128 — 25.0 200/50/3 1 173 — WS*155ED WS*155ET WS*200ED 37.5 200/50/3 2 219 — 22.6–26.9 380–415/50/3 2 102–105 105–109 33.8–40.4 380–415/50/3 2 123–129 126–132 45.1–53.8 380–415/50/3 2 144–152 148–156 25.0 200/50/3 1 206 — 37.5 200/50/3 2 251 — 50.0 200/50/3 2 296 — WS*200ET Note: * All units to be installed under local codes. Table 66. WS* electric characteristics—evaporator fan motor—50 cycle Standard Evaporator Motor No. Motors Volts WS*155ED 1 380–415/50/3 3 WS*155ET 1 200/50/3 3 WS*200ED 1 380–415/50/3 3 WS*200ET 1 200/50/3 3 Model Ph Watts Oversize Evaporator Motor Service No. Factor Motors Ph Watts FLA LRA Service Factor 380–415/50/3 3 2200 5.7 57.0 1.5 — — — — — — 1 380–415/50/3 3 3700 7.4 71.9 1.15 — — — — — — — FLA LRA 1500 4.6 36.4 1.15 1 2200 10.8 108 1.5 — 2200 5.7 57.0 1.5 3700 16.6 120 1.15 Volts Table 67. WS* electric characteristics—compressor motor and condenser motor—50 cycle Compressor Motors Condenser Fan Motors Amps(a) Unit Model No. Ph Watts rpm RLA LRA Ampsa No. Volts No. Ph Watts FLA LRA WS*155ED 2 380–415/50 3 6400 2900 14 101 2 1 300 1.6 3.8 WS*155ET 2 200/50 3 6400 2900 28 179 2 1 300 2.6 8.7 WS*200ED 2 380–415/50 3 2900 19.9 142 2 1 665 2.5 5.8 WS*200ET 2 200/50 3 2900 43 267 2 1 665 4.4 14.8 (a) For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. *Indicates both downflow and horizontal units. RT-PRC034-EN 65 Typical Wiring Figure 2. TS*155F–250F 66 RT-PRC034-EN Typical Wiring Figure 2. (continued from previous page) TS*155F–250F ** RT-PRC034-EN 67 Typical Wiring Figure 3. TS*200F–250F 68 RT-PRC034-EN Typical Wiring \ Figure 3. (continued from previous page) TS*200F–250F ** RT-PRC034-EN 69 70 13 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 2P (BL) W6 1P (RD) W5 12 L2 2A, 2B, 2C, L1 HTB1 1B(RD) 2B(BL) 3B(BK) 1A(RD) 2A(BL) 3A(BK) 3A, 3B, 3D 3P (BK) L3 LINE VOLTAGE 1A, 1B, 1D, 11 10 9 8 7 6 5 4 3 2 1 1D(RD) 2C(BL) 3D(BK) 1P 2P 3P PHM L1 L2 L3 1E(RD) 1D ,E (RD) 1C(RD) 1B ,C(RD) BLACK BLACK CC1 F F CC1 T1 T2 T1 T2 T1 T2 CC2 22 A,B (RD) 21A(BL) BLACK 10A ,B(RD) 5A(BL) 9A(RD) 8A(BL) BLACK GREEN CCH2 L1 L2 CC2 GREEN CCH1 L1 L2 L1 L2 FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. USE COPPER CONDUCTORS ONLY! CAUTION 22B(RD) 10B(RD) 9A(RD) 8A(BL) 3A(BK) 9 22A(RD) 21A(BL) 3D(BK) 10A(RD) 5A(BL) 3B(BK) 9B(RD) 8B(BL) 3 FTB-C 8 FTB-D 3C(BK) FTB-B T1 T2 T3 T1 T2 T3 11 L1 L2 L3 NE PAS RESPECTER CES MESURES DE PRÉCAUTION PEUT ENTRAÎNER DES BLESSURES GRAVES POUVANT ÊTRE MORTELLES. COUPER TOUTES LES TENSIONS ET OUVRIR LES SECTIONNEURS À DISTANCE, PUIS SUIVRE LES PROCÉDURES DE VERROUILLAGE ET DES ÉTIQUETTES AVANT TOUTE INTERVENTION. VÉRIFIER QUE TOUS LES CONDENSATEURS DES MOTEURS SONT DÉCHARGÉS. DANS LE CAS D'UNITÉS COMPORTANT DES ENTRAÎNEMENTS À VITESSE VARAIBLE, SE REPORTER AUX INSTRUCTIONS DE L'ENTRAÎNEMENT POUR DÉCHARGER LES CONDENSATEURS. DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCK OUT AND TAG PROCEDURES BEFORE SERVICING. INSURE THAT ALL MOTOR CAPACITORS HAVE DISCHARGED STORED VOLTAGE. UNITS WITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. CPR2 CPR1 IDM AVERTISSEMENT EL NO REALIZAR LO ANTERIORMENTE INDICADO, PODRÍA OCASIONAR LA MUERTE O SERIAS LESIONES PERSONALES. DESCONECTE TODA LA ENERGÍA ELÉCTRICA, INCLUSO LAS DESCONEXIONES REMOTAS Y SIGA LOS PROCEDIMIENTOS DE CIERRE Y ETIQUETADO ANTES DE PROCEDER AL SERVICIO. ASEGÚRESE DE QUE TODOS LOS CAPACITORES DEL MOTOR HAYAN DESCARGADO EL VOLTAJE ALMACENADO. PARA LAS UNIDADES CON EJE DE DIRECCIÓN DE VELOCIDAD VARIABLE, CONSULTE LAS INSTRUCCIONES PARA LA DESCARGA DEL CONDENSADOR. iVOLTAJE PELIGROSO! ADVERTENCIA SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADAS PARA ACEPTAR OTROS TIPOS DE CONDUCTORES. TENSION DANGEREUSE! FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. ATTENTION ¡UTILICE ÚNICAMENTE CONDUCTORES DE COBRE! HAZARDOUS VOLTAGE! WARNING L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUT ENDOMMAGER L'ÉQUIPEMENT. LES BORNES DE L'UNITÉ NE SONT PAS CONÇUES POUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! PRECAUCIÓN LEGEND OUTDOOR MOTOR CAPACITOR FAN TERMINAL BLOCK GAS VALVE LOW PRESSURE CONTROL OUTDOOR AIR SENSOR RETURN HUMIDITY SENSOR PHASE MONITOR COMBUSTION FAN MOTOR PLUG PPF11,PPM11 IGNITION CONTROL PLUG IGNITER PLUG PPF4,PPM4 PPF3 ECONOMIZER PLUG THERMOSTAT DISCHARGE LINE CKT 2 TDL2 PPF6,PPM6 THERMOSTAT DISCHARGE LINE CKT 1 TDL1 ZONE SENSOR MODULE EXHAUST FAN RELAY ZSM XFR SPACE HUMIDITY SENSOR SHS PHM REHEAT VALVE CONTROL POWER TRANSFORMER IGNITION TRANSFORMER RHV TNS1 TNS2 FAN FAILURE LIMIT HIGH LIMIT CUTOUT TCO2 TIMED OVERIDE TIOR TRANE COMMUNICATION INTERFACE SUPPLY HIGH TEMPERATURE TCO1 TCI SHT REMOTE MINIMUM POSITION SUPPLY AIR SENSOR RMP RETURN HIGH TEMPERATURE SAS RHT RHS RAS OUTDOOR FAN MOTOR OUTDOOR FAN RELAY RETURN AIR SENSOR ODF1,ODF2 ODM1,ODM2 OUTDOOR HUMIDITY SENSOR OAS OHS LPC3 50 64 41-46 50 50,75 90-102 80 99 13-15 81 71 41 58 72 72 69 63 66 91 98 66 98 96 69,68,34,38 33,37 100 70 71 78,80 IGNITION PROBE LOW VOLTAGE TERM BLOCK LOW PRESSURE CONTROL LTB 74,50 17 10 64,65 76 16,17,18 17,18 100 93 91 21,26 98 41,42 43 33,37 23,28 64,65 91 LINE NUMBER LPC1,LPC2 IP HI VOLTAGE TERMINAL BLOCK INDOOR FAN MOTOR IGNITION CONTROL MODULE IDM IGN HTB1 HIGH PRESSURE CONTROL GV HPC1,HPC2 FTB COMMUNICATION MODULE RELIATEL REFRIGERATION MODULE RELIATEL OPTIONS MODULE COMM RTRM RTOM ECONOMIZER ACTUATOR FAN FAILURE SWITCH INDOOR FAN CONTACTOR DISCHARGE TEMPERATURE SENSOR DTS ECA FFS F EXHAUST FAN RELAY EXF COMPRESSOR CLOGGED FILTER SWITCH CFS CPR1,CPR2 COMBUSTION FAN RELAY COMBUSTION FAN MOTOR CFR CFM CF1,CF2 COMPRESSOR CONTACTOR CRANKCASE HEATER CC1,CC2 BUILDING MANAGEMENT SYSTEM DESCRIPTION CCH1,CCH2 BMS DEVICE DESIGNATION Typical Wiring Figure 4. YS*155F–250F RT-PRC034-EN RT-PRC034-EN 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 W6 (BL) W5, 6K ,D(RD) W13(RD) 12B,C(BL) 6D(RD) 12B, 14F (GR) 14G(WH) 14F(GR) X2 H1 13C (BK) X1 115V 12B,C(BL) Y1 230V 14C (GR) 14G (WH) 13C (BK) Y2 CC2 T3 T3 TNS2 L2 L1 IGN 12C(BL) S2 S1 SPLICE 31A,C,D ,E(RD) 6D(RD), 6E(PR) 24V 460V 400V LINE 61 COM 17F (RD) 16F (RD) L1 CBM TNS1 7 1 ODF1 CF2 CF1 36B,J,W 112A(BK) CFR 107B(RD) 109A(RD) W34(PR) 575V HI IGN LO MARKED TERMINAL FOR 10MFD CAPACITORS ONLY 107A(RD) 26C(BK) W13, 6K (RD) W14(RD) 8 (BK) 4C(BK) W28 ,26C W28, 415V H3 575V L3 L3 CC1 W34(PR) 14C(GR) (BL) 380V H2 460V 12J 12B ,J, W6 (BL) W5, 6K ,D(RD), 6C(PR) MARKED TERMINAL FOR 10MFD CAPACITORS ONLY CFR 3 TAN PPM4-2 TAN 110A(PR) PPF11-4 PPF11-3 IP PPF11-1 4 113A(OR) RED PURPLE PPM11-1 BROWN BROWN BLACK PPM11-4 ORANGE PPM11-3 PPM11-2 ODM2 ODM1 PPF11-2 108A(RD) CFR 112B(BK) 2 PPM4-1 ,36V(GR) PPF4-2 (BL) 1 112A,B(BK) PPF4-1 110A, W34 (PR) 3 15A(BK) 11A(BR) 6E(PR) 4C(BK) 7A(BR) 6C(PR) CFM GREEN/YELLOW F). BLUE BROWN GREEN ORANGE BR GR OR BLACK COLOR YELLOW YL TAN WHITE WH TN RED PURPLE RD PR ABBR WIRE COLOR DESIGNATION BL BK ABBR COLOR CONNECTIONS SHOWN ARE FOR 460V/60HZ/3PH OR 380V/ 50HZ/3PH. WHEN 575V/60HZ/3PH OR 415V/50HZ/3PH UNIT OPERATION IS REQUIRED, REMOVE WIRES 12B,C(BL) FROM H2 TERMINAL ON TNS2, AND CONNECT TO H3 TERMINAL ON TNS2 CONNECTIONS SHOWN ARE FOR 460V/60HZ/3PH OR 380-415V/ 50HZ/3PH. WHEN 575V/60HZ/3PH UNIT OPERATION IS REQUIRED, REMOVE WIRE 12C(BL) FROM 460V/400V TERMINAL ON TNS1 AND CONNECT TO 575V TERMINAL ON TNS1. THREE PHASE MOTORS ARE PROTECTED UNDER PRIMARY SINGLE PHASING CONDITIONS. ALL MOTORS HAVE INTERNAL OVERLOAD PROTECTION. COMPRESSORS HAVE INTERNAL THERMAL PROTECTION. NUMBERS ALONG THE RIGHT SIDE OF THE SCHEMATIC DESIGNATE THE LOCATION OF CONTACTS BY LINE NUMBER. AN UNDERLINED NUMBER INDICATES A NORMALLY CLOSED CONTACT. DASHED LINES INDICATE RECOMMENDED FIELD WIRING BY OTHERS. DASHED LINE ENCLOSURES AND/OR DASHED DEVICE OUTLINES INDICATE COMPONENTS PROVIDED BY THE FIELD. PHANTOM LINE ENCLOSURES INDICATE ALTERNATE CIRCUITRY OR AVAILABLE SALES OPTIONS. UNLESS OTHERWISE NOTED ALL SWITCHES ARE SHOWN AT 25 C (77 F), AT ATMOSPHERIC PRESSURE. AT 50% RELATIVE HUMIDITY, WITH ALL UTILITIES TURNED OFF, AND AFTER A NORMAL SHUTDOWN HAS C (77 OCCURED. ALL THERMISTORS ARE 10K AT 25 11 TERMINALS MAY NOT BE PRESENT. 8 7 4 3 2 1 NOTES: Typical Wiring Figure 4. (continued from previous page) YS*155F–250F 11 X 17 METAL PLATE 71 72 13 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 2P (BL) W6 1P (RD) W5 12 L2 2A, 2B, 2C, L1 HTB1 1B(RD) 2B(BL) 3B(BK) 1A(RD) 2A(BL) 3A(BK) 3A, 3B, 3D 3P (BK) L3 LINE VOLTAGE 1A, 1B, 1D, 11 10 9 8 7 6 5 4 3 2 1 1D(RD) 2C(BL) 3D(BK) 1P 2P 3P PHM L1 L2 L3 1E(RD) 1D ,E (RD) 1C(RD) 1B ,C(RD) BLACK BLACK CC1 F F CC1 T1 T2 T1 T2 T1 T2 CC2 22 A,B (RD) 21A(BL) BLACK 10A ,B(RD) 5A(BL) 9A(RD) 8A(BL) BLACK GREEN CCH2 L1 L2 CC2 GREEN CCH1 L1 L2 L1 L2 FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. USE COPPER CONDUCTORS ONLY! CAUTION 22B(RD) 10B(RD) 9A(RD) 8A(BL) 3A(BK) 9 22A(RD) 21A(BL) 3D(BK) 10A(RD) 5A(BL) 3B(BK) 9B(RD) 8B(BL) 3 FTB-C 8 FTB-D 3C(BK) FTB-B T1 T2 T3 T1 T2 T3 11 L1 L2 L3 NE PAS RESPECTER CES MESURES DE PRÉCAUTION PEUT ENTRAÎNER DES BLESSURES GRAVES POUVANT ÊTRE MORTELLES. COUPER TOUTES LES TENSIONS ET OUVRIR LES SECTIONNEURS À DISTANCE, PUIS SUIVRE LES PROCÉDURES DE VERROUILLAGE ET DES ÉTIQUETTES AVANT TOUTE INTERVENTION. VÉRIFIER QUE TOUS LES CONDENSATEURS DES MOTEURS SONT DÉCHARGÉS. DANS LE CAS D'UNITÉS COMPORTANT DES ENTRAÎNEMENTS À VITESSE VARAIBLE, SE REPORTER AUX INSTRUCTIONS DE L'ENTRAÎNEMENT POUR DÉCHARGER LES CONDENSATEURS. DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCK OUT AND TAG PROCEDURES BEFORE SERVICING. INSURE THAT ALL MOTOR CAPACITORS HAVE DISCHARGED STORED VOLTAGE. UNITS WITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. CPR2 CPR1 IDM AVERTISSEMENT EL NO REALIZAR LO ANTERIORMENTE INDICADO, PODRÍA OCASIONAR LA MUERTE O SERIAS LESIONES PERSONALES. DESCONECTE TODA LA ENERGÍA ELÉCTRICA, INCLUSO LAS DESCONEXIONES REMOTAS Y SIGA LOS PROCEDIMIENTOS DE CIERRE Y ETIQUETADO ANTES DE PROCEDER AL SERVICIO. ASEGÚRESE DE QUE TODOS LOS CAPACITORES DEL MOTOR HAYAN DESCARGADO EL VOLTAJE ALMACENADO. PARA LAS UNIDADES CON EJE DE DIRECCIÓN DE VELOCIDAD VARIABLE, CONSULTE LAS INSTRUCCIONES PARA LA DESCARGA DEL CONDENSADOR. iVOLTAJE PELIGROSO! ADVERTENCIA SI NO LO HACE, PUEDE OCASIONAR DAÑO AL EQUIPO. LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADAS PARA ACEPTAR OTROS TIPOS DE CONDUCTORES. TENSION DANGEREUSE! FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. ATTENTION ¡UTILICE ÚNICAMENTE CONDUCTORES DE COBRE! HAZARDOUS VOLTAGE! WARNING L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUT ENDOMMAGER L'ÉQUIPEMENT. LES BORNES DE L'UNITÉ NE SONT PAS CONÇUES POUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! PRECAUCIÓN LEGEND OUTDOOR MOTOR CAPACITOR FAN TERMINAL BLOCK GAS VALVE LOW PRESSURE CONTROL OUTDOOR AIR SENSOR RETURN HUMIDITY SENSOR PHASE MONITOR EXHAUST FAN RELAY PPF3 PPF11,PPM11 PPF4,PPM4 COMBUSTION FAN MOTOR PLUG IGNITER PLUG IGNITION CONTROL PLUG ECONOMIZER PLUG TDL2 PPF6,PPM6 THERMOSTAT DISCHARGE LINE CKT 1 THERMOSTAT DISCHARGE LINE CKT 2 TDL1 ZONE SENSOR MODULE XFR ZSM PHM REHEAT VALVE SPACE HUMIDITY SENSOR RHV SHS CONTROL POWER TRANSFORMER IGNITION TRANSFORMER TNS2 TNS1 HIGH LIMIT CUTOUT FAN FAILURE LIMIT TIMED OVERIDE TCO2 TIOR TRANE COMMUNICATION INTERFACE SUPPLY HIGH TEMPERATURE TCO1 TCI SHT REMOTE MINIMUM POSITION SUPPLY AIR SENSOR RMP RETURN HIGH TEMPERATURE SAS RHT RHS RAS OUTDOOR FAN MOTOR OUTDOOR FAN RELAY RETURN AIR SENSOR ODF1,ODF2 ODM1,ODM2 OUTDOOR HUMIDITY SENSOR OAS OHS LPC3 50 64 41-46 50 50,75 90-102 80 99 13-15 81 71 41 58 72 72 69 63 66 91 98 66 98 96 69,68,34,38 33,37 100 70 71 78,80 IGNITION PROBE LOW VOLTAGE TERM BLOCK LOW PRESSURE CONTROL LTB 74,50 17 10 64,65 76 16,17,18 17,18 100 93 91 21,26 98 41,42 43 33,37 23,28 64,65 91 LINE NUMBER LPC1,LPC2 IP HI VOLTAGE TERMINAL BLOCK INDOOR FAN MOTOR IGNITION CONTROL MODULE IDM IGN HTB1 HIGH PRESSURE CONTROL GV HPC1,HPC2 FTB COMMUNICATION MODULE RELIATEL REFRIGERATION MODULE RELIATEL OPTIONS MODULE COMM RTRM RTOM ECONOMIZER ACTUATOR FAN FAILURE SWITCH INDOOR FAN CONTACTOR DISCHARGE TEMPERATURE SENSOR DTS ECA FFS F EXHAUST FAN RELAY EXF COMPRESSOR CLOGGED FILTER SWITCH CFS CPR1,CPR2 COMBUSTION FAN RELAY COMBUSTION FAN MOTOR CFR CFM CF1,CF2 COMPRESSOR CONTACTOR CRANKCASE HEATER CC1,CC2 BUILDING MANAGEMENT SYSTEM DESCRIPTION CCH1,CCH2 BMS DEVICE DESIGNATION Typical Wiring Figure 5. YS*200F–250F RT-PRC034-EN RT-PRC034-EN 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 W6 (BL) W5, 6K ,D(RD) W13(RD) 12B,C(BL) 6D(RD) 12B, 14F (GR) 14G(WH) 14F(GR) X2 H1 13C (BK) X1 115V 12B,C(BL) Y1 230V 14C (GR) 14G (WH) 13C (BK) Y2 CC2 T3 T3 TNS2 L2 L1 IGN 12C(BL) S2 S1 SPLICE 31A,C,D ,E(RD) 6D(RD), 6E(PR) 24V 460V 400V LINE 61 COM 17F (RD) 16F (RD) L1 CBM TNS1 7 W34(PR) 575V HI IGN LO MARKED TERMINAL FOR 10MFD CAPACITORS ONLY 107A(RD) 26C(BK) W13, 6K (RD) W14(RD) 8 (BK) 4C(BK) W28 ,26C W28, 415V H3 575V L3 L3 CC1 W34(PR) 14C(GR) (BL) 380V H2 460V 12J 12B ,J, W6 (BL) 1 ODF1 CF2 CF1 36B,J,W 112A(BK) CFR 107B(RD) 109A(RD) W5, 6K ,D(RD), 6C(PR) MARKED TERMINAL FOR 10MFD CAPACITORS ONLY CFR 3 TAN PPM4-2 TAN 110A(PR) PPF11-4 PPF11-3 IP PPF11-1 4 113A(OR) RED PURPLE PPM11-1 BROWN BROWN BLACK PPM11-4 ORANGE PPM11-3 PPM11-2 ODM2 ODM1 PPF11-2 108A(RD) CFR 112B(BK) 2 PPM4-1 ,36V(GR) PPF4-2 (BL) 1 112A,B(BK) PPF4-1 110A, W34 (PR) 3 15A(BK) 11A(BR) 6E(PR) 4C(BK) 7A(BR) 6C(PR) CFM GREEN/YELLOW BROWN GREEN ORANGE BR GR OR BLUE BLACK COLOR TN YL WH RD PR ABBR WIRE COLOR DESIGNATION BL BK ABBR 11 TERMINALS MAY NOT BE PRESENT. TAN YELLOW WHITE RED PURPLE COLOR CONNECTIONS SHOWN ARE FOR 460V/60HZ/3PH OR 380V/ 50HZ/3PH. WHEN 575V/60HZ/3PH OR 415V/50HZ/3PH UNIT OPERATION IS REQUIRED, REMOVE WIRES 12B,C(BL) FROM H2 TERMINAL ON TNS2, AND CONNECT TO H3 TERMINAL ON TNS2 8 F). CONNECTIONS SHOWN ARE FOR 460V/60HZ/3PH OR 380-415V/ 50HZ/3PH. WHEN 575V/60HZ/3PH UNIT OPERATION IS REQUIRED, REMOVE WIRE 12C(BL) FROM 460V/400V TERMINAL ON TNS1 AND CONNECT TO 575V TERMINAL ON TNS1. THREE PHASE MOTORS ARE PROTECTED UNDER PRIMARY SINGLE PHASING CONDITIONS. ALL MOTORS HAVE INTERNAL OVERLOAD PROTECTION. COMPRESSORS HAVE INTERNAL THERMAL PROTECTION. NUMBERS ALONG THE RIGHT SIDE OF THE SCHEMATIC DESIGNATE THE LOCATION OF CONTACTS BY LINE NUMBER. AN UNDERLINED NUMBER INDICATES A NORMALLY CLOSED CONTACT. DASHED LINES INDICATE RECOMMENDED FIELD WIRING BY OTHERS. DASHED LINE ENCLOSURES AND/OR DASHED DEVICE OUTLINES INDICATE COMPONENTS PROVIDED BY THE FIELD. PHANTOM LINE ENCLOSURES INDICATE ALTERNATE CIRCUITRY OR AVAILABLE SALES OPTIONS. UNLESS OTHERWISE NOTED ALL SWITCHES ARE SHOWN AT 25 C (77 F), AT ATMOSPHERIC PRESSURE. AT 50% RELATIVE HUMIDITY, WITH ALL UTILITIES TURNED OFF, AND AFTER A NORMAL SHUTDOWN HAS OCCURED. ALL THERMISTORS ARE 10K AT 25 C (77 7 4 3 2 1 NOTES: Typical Wiring Figure 5. (continued from previous page) YS*200F–250F 11 X 17 METAL PLATE 73 Typical Wiring Figure 6. TS*155F–250F 74 RT-PRC034-EN Typical Wiring Figure 6. (continued from previous page) TS*155F–250F ** RT-PRC034-EN 75 76 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 LTB-3 31B(RD) LTB-1 31A,B(RD) 31C(RD) 31D(RD) 29 29 LTB-4 LTB-2 31E(RD) BLUE YELLOW 30 LPC2 LPC1 (ZTEMP)1 (LED_COMMON)6 (HEAT)7 (COOL)8 (SYS_ON)9 17 (SERVICE)10 (HSP)5 (MODE)4 (CSP)3 (SIGNAL_COMMON)2 ZSM LTB-6 SHT 19 TYPICAL ZONE SENSOR 118A(PR) W8(PR) RHT 31 LTB-5 YELLOW BLUE 50A(BL) 52 51 LTB-TEST 1 52E(BL) 51B(PR) 117A(PR) 37C(PR) SPLICE BLACK P1-14 P1-13 P3-2 P1-8 P8-1 P8-2 36BX(BlU) 56A(PR) C SPLICE BLACK Y P1-1 P3-1 W38(RD) YOUT P1-12 PHM LTB-TEST 2 OAS 136A(RD) 31A,C,D,E (RD) CPR2 J6-7 (0-30 VDC) J6-8 (0-30 VDC) J6-9 (0-30 VDC) TEST INPUT DISABLE J6-10 (0-30 VDC) J6-6 (COM) CPR1 OUTDOOR AIR TEMP DISABLE ZSM J6-5 (0-5 VDC) J6-4 (0-5 VDC) J6-3 (0-5 VDC) J6-2 (COM) J6-1 (0-5 VDC) J1-14 (COM) J1-13 J3-2 J1-8 J8-1 J8-2 (EMER STOP) J1-12 (24 VAC) J3-1 (24 VAC) J1-1 RTRM J3-7 J1-9 J3-3 J3-4 J1-10 J1-11 J5-3 J1-3 J5-4 24 VAC J4-1 (MODBUS) J4-2 + J4-5 MODBUS COMM OUT - J4-4 NON HEAT PUMP CONFIG J3-6 J5-1 (24 VAC) IGN COMM + K7 LEAD/ J3-8 LAG LOCKOUT K10 K6 COMMON K9 J1-2 P14-1 P14-2 P14-4 P14-5 P1-5 P1-3 P5-4 P5-3 P5-1 P3-6 P3-8 P3-7 P1-9 P3-3 P3-4 P1-10 P1-11 P1-2 24V LINE 59 P 41A(RD) 40A(BL) 39A(BK) 38A(BK) 59A(PR) 59A(PR) 82A(BK) 81A(BK) 68A(YL) TC01 80A(YL) 36BY(BL) 61A(YL) 63A(YL) 86A(YL) 84A(YL) 64A(BK) 36A(BL) 33 RED BLACK RED BLACK TB1 J1-1 J1-2 J1-3 TRANE BUILDING MANAGEMENT SYSTEM P21-1 P21-2 P21-3 J1-12 J1-10 J1-7 TC02 IGN RED BLACK J1-6 J1-8 HPC2 HPC1 COMM OUT - IN OUT 24 VAC COMMON - IN 90A(YL) 87A(YL) 42D(BR) J2-1 J2-2 J2-4 J2-5 PPF3-6 PPF5-1 PPF5-2 PPF5-4 PPF5-5 83A(BR) PPF3-8 RED BLACK +MODBUS+ TCI/LCI/NCI J1-4 PPF3-12 PPF3-10 PPF3-7 P21-4 85A(BR) 36BZ(BL) TDL2 TDL1 P CC2 3 W66(RD) W65(BL) W64(BK) TH 61A(YL) W63(BK) 35 63A(YL) CC1 GV MAIN 1 TR 2 104A(BL) DTS F P11-1 103A(PR) P4-4 P4-5 P13-1 P13-2 PPM8-4 P11-4 PPM8-3 P11-3 PPM8-2 P11-2 PPM8-1 36J(BL) BLACK PPF8-4 PPF8-3 PPF8-2 PPF8-1 ODF1 64A(BK) J1-3 J4-4 J4-5 J3-1 J3-2 J1-4 COMMON COMMON DISCHARGE AIR SENSOR CONFIG COMMON SUPPLY AIR TEMPERING 24 VAC ,36BZ(BL) RTOM 36AS(BL) J1-1 + MODBUS COMM J1-2 - 36B(BL) 36A,F,W,AS(BL) 36A(BL) 36B,J,W(BL), 36V(GR) F-17,18 CC1-21,22,34 CC2-26,27,35 36V(GR) Figure 7. 62 61 Typical Wiring YS*155F–250F RT-PRC034-EN RT-PRC034-EN INSET E - PROGRAMMABLE ZONE SENSOR/ REMOTE PANEL W/NSB 120 119 118 117 116 115 114 113 112 111 110 109 15 NOTES: 15 1 OPTIONAL REMOTE SENSOR S1 S2 A1 A2 17 10 9 8 7 14 HEAT OFF COOL FAN COOL 2 COOL 1 AUTO ON INSTALL OPTIONAL REMOTE SENSOR TO TERMINALS S1 AND S2 WHEN REQUIRED. SEE PROGRAMMABLE ZONE SENSOR / REMOTE PANEL W/ NSB LITERATURE FOR OPTION CONFIGURATION. ALL UNITS SHIP WITH AN OPTIONS HARNESS ROUTED FROM THE CONTROL BOX TO THE RETURN AIR SECTION. DO NOT CONNECT THE OPTIONS HARNESS PPF5 TO THE RTRM IF NO OPTIONS ARE INSTALLED. DO NOT CONNECT OPTIONS HARNESS PPM8 TO THE RTOM IF NO ECA IS INSTALLED. REFER TO ACCOMPANYING LITERATURE FOR CONNECTION / COMBINATION OF OPTIONAL COMPONENTS. 15 28 12 108 A3 11 107 106 105 104 103 102 101 100 99 HEAT OFF COOL 97 98 COOL 96 OFF HEAT THERMOSTAT 19 W2 HEAT 2 Y2 Y1 THALPY CONTROL. REQUIRED FOR OPTIONAL REFERENCE ENTH REQUIRED FOR OPTIONAL COMPARATIVE EN 21 25 28 26 0-10 VDC Duct Mounted Sensor Only. AUXILIARY RELAY ENERGIZED DURING OCC UPIED PERIODS. OPTIONAL MAS, RAS, RHS, OHS AND ASSOCIATED WIRING NOT USED WITH MOTORIZED OUTSIDE AIR. T. ZONE SENSOR. INSET E IS FOR OPTIONAL PROGRAMMABLE 19 20 WIRE 81B(PR) USED ONLY ON SINGLE HEA WHEN OPTIONAL REMOTE MINIMUM POSITION POTENTOMETER IS REQUIRED AND WIRE AS SHOWN. ALPY CONTROL. TERMINALS 7,8,9 AND 10 ARE FOR OPTIO NAL INDICATORS. 122A(RD) (+ 25 17 23 137A(PR) GND ) 24V ( ) - - LTB 7 LTB 8 ECA EXF 24VAC 2A P24-2 P24-1 P1 P 24VAC COMMON RED WHT P17-4 P17-3 P17-1 + MODBUS P17-2 COMM - 1 24V 32 18 BLU W57(RD) W56(BL) W55(BK) W54(BK) RMP P CONNECT WIRES 36BY AND 36BZ TO ENABLE 3 STAGE COOLING ONLY ON HIGH EFFICIENCY SHORT ORIFICE UNITS. TO ENABLE COMPRESSOR LEAD/LAG OPERAT 35 IED DEVICE. ION, CUT WIRE 36B. POWER EXHAUST OUTPUT FOR FIELD SUPPL 33 TO SHUT DOWN THE UNIT FOR EMERGENCY STOP, REMOVE JUMPER AND INSTALL FIELD SUPPLIED DEVICE. TO DISABLE COMPRESSORS, REMOVE JUMPERS AND CONNECT FIELD SUPPLIED CONTROL DEVICE. 36F(BL) 2 DCV 1 OAH 2 (4-20MA) 1 RAH 2 (4-20MA) 1 COMMON 2 RAT 1 0-5VDC COMMON 2 MAT 1 0-5VC 32 30 29 P28-2 121A(BRN) P28-1 120A(BK) P12-2 P12-1 140A(RD) P9-2 P9-1 138A(RD) P10-2 P10-1 141A(PR) P23-2 P23-1 98A(PR) W44(BL) LTB 14 h + OHS h + RHS RAS 97A(PR) MAS LTB 13 139A(PR) 142A(PR) CO2 SENSOR OUT 26 21 20 21 26 21 26 26 18 J6-10 (0-30 VDC) J6-9 (0-30 VDC) J6-8 (0-30 VDC) J6-7 (0-30 VDC) J6-14 (24 VAC) J6-12 (0-40 VDC) J7-6 J7-2 J7-9 J7-4 J7-5 J7-3 J7-1 (24 VAC) RTRM J6-11 (COM) COM RH G W1 HEAT 1 RC 96A(PR) FIRE PANEL 1 3 FOS LTB9 LTB10 LTB11 PPM6-4 P6-4 124A(BK) P6-5 125A(BK) P6-6 126A(BK) P7-5 P7-6 101A(PR) P7-3 P7-4 58J(PR) P7-2 105A(PR) P7-1 2 106A(RD) 102A(RD) FFS 100A(RD) CFS PPM6-3 PPM6-2 PPM6-1 + 24 VAC (MODBUS) - COMMON J7-2 J7-1 J6-4 J6-5 J6-6 J7-5 J7-6 J7-3 PRESSURIZE PURGE EXHAUST 24 VAC FAN PROVING 24 VAC J7-4 CLOGGED FILTER J2-4 J2-3 J2-2 J2-1 MODBUS COMM Figure 7. 95 94 93 92 Typical Wiring (continued from previous page) YS*155F–250F 77 Typical Wiring Figure 8. WS*155E–250E 78 RT-PRC034-EN Typical Wiring Figure 8. (continued from previous page) WS*155E–250E * RT-PRC034-EN 79 Jobsite Connections Table 68. Typical number of wires Zone Sensors A Manual Changeover 4 Manual/Auto Changeover 5 Manual/Auto Changeover with Status Indication LED’s 10 Programmable Night Setback with Status Indication LED’s 7 Thermostats B 3 Power Wires + 1 Ground Wire (three phase) DISCONNECT SWITCH (BY OTHERS) B ZONE SENSOR OR THERMOSTAT A ROOFTOP UNIT Notes: 80 • For specific wiring information, see the installation instructions. • All wiring except power wire is low voltage. • All customer supplied wiring to be copper and must conform to applicable electrical codes (such as NEC or CEC) and local electric codes. Wiring shown dotted is to be furnished and installed by the customer. • Zone sensor required for units configured for Single Zone VAV indoor fan system control to enable Single Zone VAV functionality. RT-PRC034-EN Dimensional Data Figure 9. Cooling with optional electric heat and gas/electric models—15–25 tons—downflow unit clearance * All dimensions are in inches/millimeters. 54” (1372 mm) 1” (25 mm) DOWNFLOW CONDENSATE DRAIN CONN 1” (25 mm) NPT 26 3/4” (679 mm) 6” (152 mm) (SEE NOTE) 64 11/16” (1643 mm) 121 11/16” (3091 mm) 33 3/16” (843 mm) 8 15/16” (227 mm) 2 11/16” (68 mm) 84 3/16” (2138 mm) 7/8” (22 mm) DIA. HOLE (UNIT CONTROL WIRE) 3” (76 mm) DIA. HOLE (UNIT POWER WIRE) Figure 10. Cooling with optional electric heat and gas/electric models–15–25 tons—unit clearance and horizontal unit supply/return * All dimensions are in inches/millimeters. RT-PRC034-EN 81 Dimensional Data Figure 11. Heat pump—15 tons—downflow unit clearance * All dimensions are in inches/millimeters. (TS*/WS* MODELS ONLY) 2138 MM Figure 12. Heat pump—15 tons—unit clearance and horizontal unit supply/return * All dimensions are in inches/millimeters. 82 RT-PRC034-EN Dimensional Data Figure 13. Heat pump—20 tons—downflow unit clearance * All dimensions are in inches/millimeters. 64 1/8” 1629 MM (TS*/WS* MODELS ONLY) 2138 MM Figure 14. Heat pump—20 tons—unit clearance and horizontal unit supply/return * All dimensions are in inches/millimeters. RT-PRC034-EN 83 Dimensional Data Figure 15. Cooling and heat pump with optional electric heat and gas/electric models—15–25 tons—roof curb * All dimensions are in inches/millimeters. Figure 16. Cooling and heat pump with optional electric heat and gas/electric models 15–25 tons—downflow duct connections—field fabricated * Duct flanges mount 7-7/16" (189mm) down inside the curb on the 1.5" (38mm) curb flanges. Roofcurb is intended for downflow use only. * All dimensions are in inches/millimeters. 9 PERIMETER CURB FLANGE 84 RT-PRC034-EN Dimensional Data Figure 17. Cooling and heat pump with optional electric heat and gas/electric models 15–25 tons—downflow unit clearance * All dimensions are in inches/millimeters. Figure 18. Downflow & horizontal condensate locations Table 69. Standard efficiency units (cooling and gas/electric) Condensate Tons Downflow Only A 15–25 RT-PRC034-EN B 26 7/16” 28 3/4” 672 mm 730 mm C D 19 15/16” 506 mm 4 1/4” 108 mm Drain Size F G H 4 1/4” 76 5/16” 68 11/16” 108 mm 1938 mm 1745 mm 1 NPT Condensate Drain Location Downflow Horizontal J K 26 3/4” 679 mm 5 3/8” 137 mm 85 Dimensional Data Table 70. Cooling unit—swing diameter & through the base electrical Unit Model # A B C D E TSD/YSD 155F, 175F, 200F, 250F, WSD155E, 200E 29 1/2 56 38 1/2 18 1/2 N/A Note: *All dimensions are in inches TOP VIEW SHOWING THROUGH THE BASE ELECTRICAL UTILITY LOCATIONS AND ACCESS PANEL SWING CLEARANCES. B 6 7/8" SWING RADIUS (E) HORIZONTAL FILTER ACCESS PANEL SWING RADIUS (A) ID SECTION ACCESS PANEL SWING RADIUS (D) ID FAN SECTION ACCESS PANEL Figure 19. Fresh air hood (horizontal units) THROUGH THE BASE ELECTRICAL SWING RADIUS (C) OD SECTION ACCESS PANEL Figure 20. Fresh air hood (downflow units) FRESH AIR HOOD (MANUAL) HORIZONTAL UNITS 495 MM 19 1/2” 495 MM Figure 21. Economizer - horizontal units Figure 22. Economizer - downflow units Note: When applying economizer to horizontal units, connected ductwork must be run full size to allow proper operation of economizer damper. 86 RT-PRC034-EN Weights Table 71. TS* maximum unit and corner weights (kg) and center of gravity dimensions (mm) Max Weight (kg) Corner Weights (kg) Center of Gravity (mm) Model Shipping Net A B C D Length Width TS*155F 1022 826 268 226 162 170 149 86 TS*175F 1040 845 268 231 169 176 154 89 TS*200F 1068 873 278 233 170 191 145 90 TS*250F 1060 852 270 231 169 182 153 89 Notes: 1. Corner weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. 2. Weights are approximate. Horizontal and downflow unit and corner weights may vary slightly. 3. *Indicates both horizontal and downflow units. Table 72. TS* maximum unit and corner weights (lb) and center of gravity dimensions (inches) Max Weight (lb) Corner Weights (lb) Center of Gravity (in) Model Shipping Net A B C D Length Width TS*155F 2253 1822 590 498 358 376 59 34 TS*175F 2292 1863 591 510 372 388 61 35 TS*200F 2353 1925 614 514 375 422 57 35 TS*250F 2337 1878 595 510 372 402 60 35 Notes: 1. Corner weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. 2. Weights are approximate. Horizontal and downflow unit and corner weights may vary slightly. 3. *Indicates both horizontal and downflow units. RT-PRC034-EN 87 Weights TS* Accessories Table 73. TS* accessory net weights (kg/lb)(a), (b), (c) Economizer Model Net Outside Air Damper Motorized Manual Oversized Motor Roof Curb Adder(d) All Zone Sensors High Static Low Static Drive(d) Drive(d) TSD155F, 175F — — — — — — — TSD200F 36/79 34/75 15/33 107/236 2/4 0.5/1 1/2 — — TSD250F 36/79 34/75 15/33 107/236 — 0.5/1 — 1/2 TSH155F, 175F — — — — — — — — TSH200F 30/66 34/75 15/33 — 2/4 0.5/1 1/2 — TSH250F 30/66 34/75 15/33 — — 0.5/1 — 1/2 (a) Net weight should be added to unit weight when ordering factory installed accessories. (b) For 600V heaters net weights are same as 480 V heaters. (c) To estimate shipping weight add 2.3 kg (5 lb) to net weight. (d) Downflow only. Table 74. TS* accessory net weights (kg) Electric Heat 5–27 kW 11–14 kW 22–27 kW 22–41 kW 45–54 kW Models 380–415 kW 380–415 kW 380–415 kW 380–415 kW 380–415 kW TS*155F, 175F — 9.5 12.3 14.5 — TS*200F — — 12.3 14.5 15.4 TS*250F — — 12.3 14.5 15.4 Notes: 1. Net weight should be added to unit weight when ordering factory installed accessories. 2. For 600 V heaters net weights are same as 480 V heaters. 3. Not available on all models (see Fan Performance tables for specific models). 4. To estimate shipping weight add 5 lb (2.27 kg) to net weight. 5. TS*155F-250F factory installed options for economizers, multiply net capacity x 0.99, EER x 0.97. For oversized motors, multiply net capacity x 0.98, EER x 0.93. 6. * Indicates both downflow and horizontal units Table 75. TS* accessory net weights (lb) Electric Heat 5–27 kW 11–14 kW 22–27 kW 22–41 kW 45–54 kW 380–415 kW Models 380–415 kW 380–415 kW 380–415 kW 380–415 kW TS*155F, 175F — 21 27 32 — TS*200F — — 27 32 34 TS*250F — — 27 32 34 Notes: 1. Net weight should be added to unit weight when ordering factory installed accessories. 2. For 600 V heaters net weights are same as 480 V heaters. 3. Not available on all models (see Fan Performance tables for specific models). 4. To estimate shipping weight add 5 lb (2.27 kg) to net weight. 5. TS*155F-250F factory installed options for economizers, multiply net capacity x 0.99, EER x 0.97. For oversized motors, multiply net capacity x 0.98, EER x 0.93. 6. * Indicates both downflow and horizontal units 88 RT-PRC034-EN Weights YS* Unit & Corner Weights, Center of Gravity Table 76. YS* maximum unit and corner weights (kg) and center of gravity dimensions (mm) Max Weight Corner Weights Center of Gravity Model Shipping Net A B C D Length Width YS*155F 1100 888 285 242 175 184 148 86 YS*175F 1119 910 289 248 181 191 153 89 YS*200F 1147 939 299 250 182 206 145 90 YS*250F 1140 932 297 252 183 200 153 89 Notes: 1. Corner weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. 2. Weights are approximate. Horizontal and downflow unit and corner weights may vary slightly. 3. *Indicates both horizontal and downflow units. Table 77. YS* maximum unit and corner weights (lb) and center of gravity dimensions (inches) Max Weight Corner Weights Center of Gravity Model Shipping Net A B C D Length Width YS*155F 2424 1958 628 534 387 406 58 34 YS*175F 2467 2007 637 547 400 421 60 35 YS*200F 2528 2069 659 551 402 455 57 35 YS*250F 2513 2054 655 555 403 442 60 35 Notes: 1. Corner weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. 2. Weights are approximate. Horizontal and downflow unit and corner weights may vary slightly. 3. *Indicates both horizontal and downflow units. RT-PRC034-EN 89 Weights YS* Accessories Table 78. YS* accessory net weights (kg)(a), (b) Economizer Outside Air Damper Manual Roof Curb(d) Oversized LPG Motor Conversion Adder(c) Kit All Zone Sensors High Static Drive(c) Low Static Drive(c) Model Net Motorized YSD155F, 175F — — — — — — — — — YSD200F 36 34 15 107 2 2 0.5 1 — YSD250F 36 34 15 107 — 2 0.5 — 1 YSH155F, 175F — — — — — — — — — YSH200F 30 34 15 — 2 2 0.5 1 — YSH250F 30 34 15 — — 2 0.5 — 1 (a) Net weight should be added to unit weight when ordering factory installed accessories. (b) Not available on all models. (See fan performance table for specific models). (c) YS*155F-250F factory installed options for economizers, multiply net capacity x 0.99, EER x 0.97. For oversize motors, multiply net capacity x 0.98, EER x 0.93. (d) Downflow only. Table 79. YS* accessory net weights (lb)(a), (b) Economizer Outside Air Damper Manual Roof Curb(c) Oversized LPG Motor Conversion Adder(d) Kit All Zone Sensors High Static Drive(d) Low Static Drive(d) Model No Net Motorized YSD155F, 175F — — — — — — — — — YSD200F 79 75 33 236 4 4 1 2 — YSD250F 79 75 33 236 4 1 2 YSH155F, 175F — — — — — — — — — YSH200F 66 75 33 — 4 4 1 2 — YSH250F 66 75 33 — 4 1 — 2 (a) Net weight should be added to unit weight when ordering factory installed accessories. (b) Not available on all models. (See fan performance table for specific models). (c) Downflow only. (d) YS*155F-250F factory installed options for economizers, multiply net capacity x 0.99, EER x 0.97. For oversize motors, multiply net capacity x 0.98, EER x 0.93. 90 RT-PRC034-EN Weights WS* Unit & Corner Weights, Center of Gravity Table 80. WS* maximum unit and corner weights (kg) and center of gravity dimensions (mm) Max Weight Corner Weights Center of Gravity Model Shipping Net A B C D Length Width WS*155E 1105 899 288 234 171 207 1262 811 WS*200E 1164 956 306 220 181 268 1285 789 Notes: 1. Corner weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. 2. *Indicates both horizontal and downflow units. Table 81. WS* maximum unit and corner weights (lb) and center of gravity dimensions (inches) Max Weight Corner Weights Center of Gravity Model Shipping Net A B C D Length Width WS*155E 2435 1982 634 515 377 456 56 36 WS*200E 2566 2107 674 485 400 590 57 35 Notes: 1. Corner weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. 2. *Indicates both horizontal and downflow units. RT-PRC034-EN 91 Weights WS* Accessories Table 82. WS* accessory net weights (kg)(a), (b), (c), (d) Economizer(e) Outside Air Damper Model Net Motorized Manual Roof Curb Oversized Motor Adder(e) WSD155E — — — — — — WSD200E 36 34 15 107 2 0.5 5 — WSH155E — — — — — — — — WSH200E 30 34 15 — — 0.5 7 — Roof Curb Oversized Motor Adder(e) All Zone Sensors All Zone Sensors High Static Low Static Drive(f) Drive(f) — — (a) To estimate shipping weight add 2.3 kg to net weight. (b) Downflow only. (c) Not available on all models (see fan performance tables for specific models). (d) D = Downflow unit, H = Horizontal unit. (e) Net weight should be added to unit weight when ordering factory installed accessories. (f) Multiply by 1.25 for net weight of 200–230 V rated heaters. Table 83. WS* accessory net weights (lb)(a), (b), (c), (d) Economizer(e) Model Net Outside Air Damper Motorized Manual High Static Low Static Drive(f) Drive(f) WSD155E — — — — — — — WSD200E 79 75 33 236 4 1 11 — — WSH155E — — — — — — — — WSH200E 66 75 33 — — 1 15 — (a) To estimate shipping weight add 2.3 kg to net weight. (b) Downflow only. (c) Not available on all models (see fan performance tables for specific models). (d) D = Downflow unit, H = Horizontal unit. (e) Net weight should be added to unit weight when ordering factory installed accessories. (f) Multiply by 1.25 for net weight of 200–230 V rated heaters. Table 84. WS* accessory net weights (kg) Electric Heat 5–27 kW 11–14 kW 22–27 kW 22–41 kW 45–54 kW 380–415 kW 380–415 kW 380–415 kW 380–415 kW 380–415 kW WS*155E — 9.5 12.3 14.5 — WS*200E — — 12.3 14.5 15.4 Models Notes: 1. Net weight should be added to unit weight when ordering factory installed economizer or oversize motor. 2. Not available on all models (see Fan Performance tables for specific models). 3. To estimate shipping weight add 2.3 kg to net weight. 4. Downflow only. 5. * Indicates both downflow and horizontal units Table 85. WS* accessory net weights (lb) Electric Heat 5–27 kW 11–14 kW 22–27 kW 22–41 kW 45–54 kW Models 380–415 kW 380–415 kW 380–415 kW 380–415 kW 380–415 kW WS*155E — 21 27 32 — WS*200E — — 27 32 34 Notes: 1. Net weight should be added to unit weight when ordering factory installed economizer or oversize motor. 2. Not available on all models (see Fan Performance tables for specific models). 3. To estimate shipping weight add 5 lb to net weight. 4. Downflow only. 5. * Indicates both downflow and horizontal units 92 RT-PRC034-EN Mechanical Specifications General The units shall be dedicated downflow or horizontal airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 500 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal, service panels shall have lifting handles and no more than three screws to remove. All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2-inch, 1-pound density foil-faced, fire-resistant, permanent, odorless, glass fiber material. The base of the downflow unit shall be insulated with 1/2-inch, 1-pound density foil-faced, closed-cell material. The downflow unit’s base pan shall have no penetrations within the perimeter of the curb other than the raised 11/8-inch high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting. Discharge Line Thermostat A bi-metal element discharge line thermostats installed as a standard option on the discharge line of each system. This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control. When the discharge temperature raises high above the protection limit, the bi-metal disc in the thermostat switches to off position to open the 24 Vac circuit. When the temperature on discharge line cools down, the bi-metal disc closes the contactor circuit to provide power to compressor. When the thermostat opens the fourth time, the ReliaTel™ control must be manually reset to resume operation on that stage. Unit Top The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage. Filters Two inch standard filters shall be factory supplied on all units. Optional 2-inch MERV 8 and MERV 13 filters with a filter removal too shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors. All models shall have crankcase heaters, low and high pressure control as standard. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions. These are standard on all Voyager™ models. RT-PRC034-EN 93 Mechanical Specifications Refrigerant Circuits Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices, service pressure ports, and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Internally finned, 5/16” copper tubes mechanically bonded to a configured aluminum plate fin shall be standard for evaporator coils. Condenser coils may also be microchannel type (major design sequence F units only). Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 225 psig and pressure tested to 450 psig. All dual compressor units shall have intermingled evaporator coils. Sloped condensate drain pans are standard. Round tube plate fin type condenser coils are patent-pending 1+1+1 coils, permanently gapped for easy cleaning. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components. A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a negative pressure gas valve shall be used that requires blower operation to initiate gas flow. On an initial call for heat, the combustion blower shall purge the heat exchanger 45 seconds before ignition. After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas or propane (field installed kit) and shall also comply with California requirements for low NOx emissions. The 15– 25 tons shall have two stage heating (Gas/Electric Only). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and shall have builtin thermal overload protection. Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves. All motors shall be thermally protected. Oversized motors shall be available for high static application. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. ReliaTel controls shall be provided for all 24-volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. Defrost Controls Adaptive demand defrost shall be provided to permit defrost wherever coil icing conditions begin to significantly reduce unit capacity. 94 RT-PRC034-EN Mechanical Specifications Factory Installed Options Black Epoxy Coated Pre-Coated Coils The black epoxy coils have a thermoset vinyl coating that is bonded to the aluminum fin stock prior to the fin-stamping process. The pre-coated coils are an economical option for protection in mildly corrosive environments. CO2 Sensor Wiring The unit wiring for field installed C02 sensors. Factory-installed C02 sensor wiring saves time and ensures proper unit connections for the field installed C02 sensor kits. Complete Coat™ Microchannel Condenser Coil The cathodic epoxy type electrodisposition coating is formulated for high edge build to a number of different types of heat exchangers. The coating is selected to provide excellent resistance and durability to corrosive effects of alkalies, acids, alcohols, petroleum, seawater, salty air and other corrosive environments. This coating shall be available on microchannel condenser coils. Condensate Overflow Switch This option shall shut the unit down in the event that a clogged condensate drain line prevents proper condensate removal from the unit. Hinged Access Doors Sheet metal hinges are available on the Filter, Evaporator, Fan/Motor and the Compressor/Control Access Doors. This option is available on all models. Stainless Steel Drain Pan This option provides excellent corrosion and oxidation resistance. Drain pan shall be reversible and constructed of 304 stainless steel. Stainless Steel Heat Exchanger Gas heat exchanger shall be of drum and tube design constructed from a minimum 304 Grade stainless steel. The stainless steel heat exchanger shall have a 10-year warranty as standard (Gas/ Electric Only). Through the Base Electrical with Circuit Breaker This option is a thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. The circuit breaker will be installed in a water tight enclosure in the unit with access through a swinging door. Factory wiring will be provided from the switch to the unit high voltage terminal block. The circuit breaker will provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. This option is available on all downflow models. Through the Base Electrical With Disconnect Switch Three-pole, molded case, disconnect switch with provisions for through the base electrical connections are available. The disconnect switch will be installed in the unit in a water tight enclosure with access through a swinging door. Factory wiring will be provided from the switch to the unit high voltage terminal block. The switch will be UL/CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit overcurrent protection. This option is available on all downflow models. Through the Base Utilities Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid-tight conduit and an external field installed disconnect switch. RT-PRC034-EN 95 Mechanical Specifications Two-Inch Pleated Filters Two-inch MERV 8 and MERV 13 media filters with filter removal tool shall be available on all models. Factory or Field Installed Options Clogged Filter/Fan Failure Switch A dedicated differential pressure switch is available to achieve active fan failure indication and/or clogged filter indication. These indications will be registered with either a zone sensor with status indication lights or an Integrated Comfort™ System. These options allow for individual fan failure and dirty filter indication. The fan failure switch will disable all unit functions and “flash” the Service LED on the zone sensor. The dirty filter switch will light the Service LED on the zone sensor and will allow continued unit operation. Discharge Air Sensing Kit This kit provides true discharge air sensing in heating models. This sensor is a status indicator readable through Tracer™ or Tracker™. The kit is functional only with the ReliaTel™ Options Module. Economizer—Downflow The assembly includes fully modulating 0–100 percent motor and dampers, barometric relief, minimum position setting, preset linkage, wiring harness with plug, fixed dry bulb and spring return actuator. The barometric relief damper shall be standard with the downflow economizer and shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment “off” cycle. Solid state enthalpy and differential enthalpy control shall be field-installed. Electric Heaters Electric heat modules shall be available for installation within the basic unit. Electric heater elements shall be constructed of heavy-duty nickel chromium elements internally delta connected for 240 volt, wye connected for 480 and 600 volt. Staging shall be achieved through ReliaTel. Each heater package shall have automatically reset high limit control operating through heating element contactors. All heaters shall be individually fused from the factory, where required, and shall meet all NEC and CEC requirements when properly installed. Power assemblies shall provide singlepoint connection. Electric heat modules shall be UL listed or CSA certified. If ordering the Through the Base Electrical option with an Electric Heater, the heater must be factory installed. Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. LonTalk® Communications Interface The LonTalk communications interface, when installed in a Voyager unit, allows the unit to communicate as a Tracer LCI-V device or directly with generic LonTalk Network Building Automation System Controls. Trane Communication Interface This factory or field-installed option shall be provided to interface ReliaTel controlled units with the Trane Integrated Comfort systems. 96 RT-PRC034-EN Mechanical Specifications Field Installed Options Barometric Relief Designed to be used on downflow units, barometric relief is an unpowered means of relieving excess building pressure. CO2 Sensor The CO2 sensor shall have the ability to monitor the concentration (parts per million, ppm) of CO2 (Carbon Dioxide) in the air. As the CO2 concentration changes, the outside air damper modulates to meet the current ventilation needs of the zone. Note: Choose factory-installed CO2 sensor wiring option to save time and ensure proper unit connections for the field installed CO2 sensor kits. Digital Display Zone Sensor The Digital LCD (Liquid Crystal Display) zone sensor has the look and functionality of standard zone sensors. This sensor includes a digital display of set point adjustment and space temperature in F (Fahrenheit) or C (Celsius). Includes FAN and SYSTEM buttons (supports the service functions of the standard sensor). E-squared memory stores last programmed set points. Requires 24 Vac (Volts AC). This sensor should be utilized with ReliaTel™ controls. Economizer—Horizontal The horizontal economizer shall contain the same features as the downflow economizer with the exception of barometric relief. High Static Drive The high static drive option shall allow the standard motor on the 15-, 20-, and 25-ton units to operate with improved external static capabilities. Low Static Drive The low static drive option shall allow the standard motor on the 17½- and 20-ton to operate at low static conditions. Manual Outside Air Damper The rain hood and screen shall provide up to 25 percent outside air. Motorized Outside Air Dampers Manually set outdoor air dampers shall provide up to 50 percent outside air. Once set, outdoor air dampers shall open to set position when indoor fan starts. The damper shall close to the full closed position when indoor fan shuts down. Reference or Comparative Enthalpy Reference Enthalpy is used to measure and communicate outdoor humidity. The unit receives and uses this information to provide improved comfort cooling while using the economizer. Comparative Enthalpy measures and communicates humidity for both outdoor and return air conditions, and return air temperature. The unit receives and uses this information to maximize use of economizer cooling, and to provide maximum occupant comfort control. Reference or Comparative Enthalpy option shall be available when a field installed Downflow Economizer is ordered. This option is available on all models. The powered exhaust shall provide exhaust of return air, when using an economizer, to maintain better building pressurization. RT-PRC034-EN 97 Mechanical Specifications Roof Curb—Downflow The roof curb shall be designed to mate with the downflow unit and provide support and a water tight installation when installed properly. The roof curb design shall allow field-fabricated rectangular supply/return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall be shipped knocked down for field assembly and shall include wood nailer strips. Economizer—Horizontal The horizontal economizer shall contain the same features as the downflow economizer with the exception of barometric relief. Oversized Motors Oversized motors shall be available for high static applications. Remote Potentiometer The minimum position setting of the economizer shall be adjusted with this accessory. Tool-less Hail Guards Tool-less, hail protection quality coil guards are available for condenser coil protection. Ventilation Override Accessory With the Ventilation Override Accessory installed, the unit can be set to transition up to three different pre-programmed sequences for Smoke Purge, Pressurization, and Exhaust. The transition occurs when a binary input on the RTOM is closed (shorted). This would typically be a hard wired relay output from a smoke detector or fire control panel. Zone Sensors This option shall be provided to interface with the Micro equipped Voyagers and shall be available in either manual, automatic, programmable with night setback, with system malfunction lights or remote sensor options. 98 RT-PRC034-EN Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. © 2012 Trane All rights reserved RT-PRC034-EN 20 Aug 2012 We are committed to using environmentally Supersedes RT-PRC034-EN (16 Jun 2011) conscious print practices that reduce waste.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : TCS - Unitary Copyright : ? 2008 Trane All rights reserved Create Date : 2012:07:20 08:39:50Z Job Ref : RT-PRC034-EN Keywords : Voyager, R-410A, 50Hz, Packaged Cooling, Gas/Electric & Heat Pump Rooftops, ReliaTel Modify Date : 2012:07:20 11:04:37Z Subject : Packaged Cooling, Gas/Electric & Heat Pump Rooftops Catalog Web Statement : www.trane.com XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Description : Packaged Cooling, Gas/Electric & Heat Pump Rooftops Catalog Title : Voyager™, R-410A 15-25 Tons — 50 Hz Creator : TCS - Unitary Producer : Acrobat Distiller 10.1.3 (Windows) Creator Tool : FrameMaker 10.0.2 Document ID : uuid:3975b3e0-333a-4fc0-841d-03a3769de863 Instance ID : uuid:def19357-119a-404f-8c13-10dcafc1ba24 Page Mode : UseOutlines Page Count : 100EXIF Metadata provided by EXIF.tools