Transact Campus DR4100X007 Contactless Card Readers User Manual 1353 AC3100 Installation
Blackboard Inc. Contactless Card Readers 1353 AC3100 Installation
Contents
- 1. DR4100 Brochure
- 2. DR4110 Brochure
- 3. DR4200 Brochure
- 4. DR4210 Brochure
- 5. Installation Manual
Installation Manual
AC3100 Installation Guide "Underwriters Laboratories Inc. (“UL”) has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested for fire, shock and/or casualty hazards as outlined in the U.S. and Canadian (Bi-National) Standard for Safety of Information Technology Equipment, CSA C22.2 No. 60950-1-03; UL 60950-1 First Edition dated April 1, 2003. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product. UL MAKES NO REPRESENTATIONS, WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT." Blackboard Inc. AC3100 Tested To Comply With FCC Standards FOR HOME OR OFFICE USE This Class A digital apparatus complies with Canadian ICES-003 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Part 15.21: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. This equipment complies with the FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. PRINTED APRIL 14, 2011 Contents AC3100 INSTALLATION GUIDE AC3100 Installation Mount the AC3100 Connect the AC3100 to the power source Connect the AC3100 to the network 8 AC3100 Communication Configuration 10 Configure Communication using Front Panel & Service Card 11 Configure Communication using RS-232 or Telnet 13 13 13 13 AC3100 Transaction Process Deposit Funds to an Existing Account Purchase a Visitor Card Check Account Balance 14 14 14 14 14 AC3100 Manager Card Functions Display/print transaction totals Terminal setup Display device status information Perform diagnostic functions 15 15 15 17 AC3100 Maintenance Fill the Card Dispenser Empty the Bill Box Install the Paper Roll 20 Component Replacement 20 Replace the Power Supply Fuses 23 AC3100 Features & Specifications 23 AC3100 Features: 23 AC3100 Specifications: 24 BbTS Universal Edition Changes PRINTED APRIL 14, 2011 Figures Figure 1-1 Figure 1-2 Figure 1-3 Figure 1-4 Figure 1-5 Figure 1-6 Figure 1-7 Figure 1-8 Figure 1-9 Figure 1-10 Figure 1-11 Figure 1-12 Figure 1-13 Figure 1-14 What You Get .............................................................................................1 AC3100 Reader Details..............................................................................3 Mounting Illustration ...................................................................................5 RS-485 Reader Pinout ...............................................................................7 Configuration Flowchart .............................................................................9 Out-Of-Service Codes ..............................................................................10 Configuration Command Reference.........................................................12 Bill Box Removal ......................................................................................16 AC3100 Paper roll ....................................................................................18 Paper Roll Cut-off.....................................................................................18 Paper Entry Opening................................................................................19 AC3100 Fuse Locations ...........................................................................20 AC3100 Components ...............................................................................21 Lock Lubrication .......................................................................................22 PRINTED APRIL 14, 2011 II AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 AC3100 I N S TALL A T IO N G UIDE The Blackboard AC3100 enables cardholders to deposit to accounts, check balances, and purchase visitor cards. The user interface utilizes an LCD display, keypad, and a combination mag-stripe and contactless reader. Both the UNIX Edition and Universal Edition versions of the reader support user configurable background color, text color, and banner images. Communication of host downloads, and reader transactions use a maintained Transport Layer Security (TLS) Secure Communication Channel to meet PCI Compliance. WHAT YOU GET The following items are included with each AC3100: • (2) bill boxes (one installed) • (2) paper rolls • (4) door lock keys • (4) bill box key sets • (1) hardware kit Spare Bill Box AC3100 Reader Door lock keys Paper rolls Bill Box keys Hardware kit Figure 1-1 What You Get PRINTED APRIL 14, 2011 The AC3100 connects to the Universal Edition Host via 10/100 Base-T or RS-485 through an IP Converter (IPC). In UNIX Edition, the AC3100 optionally connects via RS-485. This unit replaces the Value Transfer Station (VTS) on the UNIX Edition Host, and the Card Management Center (CMC) on the Universal Edition Host. The AC3100 accepts unattended deposits into existing cardholder accounts, and must be online to be operational. The following topics are covered in this document: • AC3100 Installation (page 1-4) • AC3100 Communication Configuration (page 1-8) • AC3100 Transaction Process (page 1-13) • AC3100 Maintenance (page 1-15) • Component Replacement (page 1-20) • AC3100 Features & Specifications (page 1-23) PRINTED APRIL 14, 2011 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 Figure 1-2 AC3100 Reader Details PRINTED APRIL 14, 2011 AC3100 INSTALLATION AC3100 I NSTALLATION Mount the AC3100 The AC3100 can be surface mounted on a wall, recessed into a wall, or mounted on a pedestal. At least four 3/8” diameter metal fasteners should be used to mount the enclosure. The installer is responsible for ensuring the unit is securely installed to prevent theft. WARNING: Use caution when opening the door without the enclosure secured to a wall or pedestal. The weight of the door when open can cause the unit to tip over and cause injury. Ensure the unit is securely mounted prior to operation. To mount the AC3100 Decide where to mount the unit, and how to route power. Conduit knockouts are located in the junction box located in the lower left of the enclosure. Power wiring must enter the unit within the junction box. Decide how to route the network wiring entering the unit. NOTE: To eliminate risk of electrical shock or injury, do not route the network cable through the junction box. Punch or drill mounting holes in either the back or the bottom of the unit, based on the application. Punch or drill a hole in the back or bottom of the cabinet to route the network cable. This hole must be large enough to accommodate the RJ45 connector. Securely mount the unit, see: Figure 1-3 Mounting Illustration (page 5). PRINTED APRIL 14, 2011 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 Wall AC3100 anchor bolts 3/8” bolt & washers 3/8” bolt & washers pedestal mount Figure 1-3 Mounting Illustration PRINTED APRIL 14, 2011 AC3100 INSTALLATION Connect the AC3100 to the power source Connect the unit to 120 VAC @ 60 Hz. Connect only to a 15A maximum branch circuit protection or equivalent. Use a circuit breaker or switch to disconnect power when installing or removing the AC3100. The AC3100 enclosure is provided with standard 1/2" conduit knockouts in the power junction box. The power requirements are 120VAC @ 60Hz, 1.5 A max (line, neutral, and earth ground). The incoming wiring must meet all applicable electrical codes. NOTE: Before connecting wiring to the AC3100, ensure that all power has been disconnected or that the circuit breaker is off. To connect the AC3100 to the power source Turn OFF the Power Supply. Remove the junction box cover in the lower left corner of the enclosure by removing the 2 screws. Connect the 120VAC external wiring to the existing wiring in the junction box using the supplied wire nuts. Wires in the junction box are color coded and labeled as shown below. Table 1-1: Junction box wiring Wire Color Label Green Description Earth Ground White Neutral Black Line (hot) Re-install the cover, and secure with two screws. Turn ON the 120VAC power supply or circuit breaker to the reader, and then turn ON the AC3100. The AC3100 powers-up and displays the power-up configuration. PRINTED APRIL 14, 2011 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 Connect the AC3100 to the network The AC3100 connects to the Universal Edition Host via 10/100 Base-T or RS-485 through an IP Converter (IPC). In UNIX Edition, the AC3100 optionally connects via the RS-485. NOTE: When connecting to a Universal Edition Host using RS-485, see: The AC3100 UE Migration Quick Start Guide for recommended steps. The network ports are identified on the LCD/PWA cover located on the door. Based on the application, plug the network cable into the appropriate RJ45 port connection. NOTE: The RS-485 cable must be terminated with the wiring configuration as shown below. RS-485 HOST Port and RJ-45 wall plate wiring 8 7 6 5 4 3 2 1 (Ground) Receive (RX-) Receive (RX+) (Ground) Transmit (TX+) Transmit (TX-) Figure 1-4 RS-485 Reader Pinout PRINTED APRIL 14, 2011 AC3100 COMMUNICATION CONFIGURATION AC3100 COMMUNICATION CONFIGURATION NOTE: The AC3100 must be configured at the host before continuing. For more information, see: The Transaction System Administration Guide, and the BbTS UNIX Edition Reference Manual. The AC3100 must be configured with communication parameters using one of three configuration methods: • Front Panel (initiated by a service card) See: Configure Communication using Front Panel & Service Card (page 1-10) • RS-232 using a terminal (i.e. computer, HyperTerminal software, and configuration cable) See: Configure Communication using RS-232 or Telnet (page 1-11) • Telnet via IP using an ethernet connection. See: Configure Communication using RS-232 or Telnet (page 1-11) NOTE: If this device accepts credit cards, Telnet must be disabled to meet PCI compliance. PRINTED APRIL 14, 2011 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 Figure 1-5 Configuration Flowchart PRINTED APRIL 14, 2011 AC3100 COMMUNICATION CONFIGURATION Configure Communication using Front Panel & Service Card To configure communication using front panel & service card Swipe the specially encoded service card, and then press NEXT. Configure each of the setup parameters, as appropriate, using the keys and display prompts. ACCEPT - Accept displayed value and advance to next setting. CHANGE - Change displayed value. ABORT - Abort configuration process. To update the IP address and related information, press CHANGE when the parameter displays, and then type in the number using zeroes (0) as placeholders. Press SAVE when prompted to save the new settings, and then reboot the AC3100. NOTE: Temporarily Out of Service displays until communication is established with the host. The 'Temporarily Out of Service' screen displays the out-of-service codes in the lower-left portion of the screen. Figure 1-6 Out-Of-Service Codes PRINTED APRIL 14, 2011 10 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 Configure Communication using RS-232 or Telnet To configure communication using RS-232 or Telnet If using RS-232, connect a configuration cable between the config port on the AC3100 and the COM port. For cable pinout, see: Configuration Cable Pinout (page 1-11). Table 1-2: Configuration Cable Pinout CONFIG Port (RJ-12) PC Serial Port DB9 Connector Signal Pin 1 Pin 5 Ground Pin 3 Pin 3 Receive (RX) Pin 4 Pin 2 Transmit (TX) Open a Terminal Program (RS-232 or Telnet). Set the following connection settings for RS-232. 9600 baud 1 stop no parity no flow control Login using the default password: IPrdr4U. The password is case sensitive. Type config, and then press Enter at the prompt. Set the configuration settings using the commands listed below. PRINTED APRIL 14, 2011 11 AC3100 COMMUNICATION CONFIGURATION Command Reference config - Configure network parameters showconfig - Display current configuration status - Display reader status ping- Ping another IP device netstats - Display network statistics netclear - Clear network statistics counters password - Change config utility password ipreboot - Reboot reader exit - Log out of session Type command, followed by ‘Enter’ key > Figure 1-7 Configuration Command Reference PRINTED APRIL 14, 2011 12 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 AC3100 TRANSACTION P ROCESS NOTE: Load paper and cards prior to performing transactions, see: AC3100 Maintenance (page 15). Perform test transactions to verify proper operation of deposits, visitor card purchases, and account balance checks. Deposit Funds to an Existing Account To deposit funds to an existing account Select Deposit Funds from the on-screen menu. NOTE: The actual verbiage of this prompt is determined by the host configuration. Follow the on-screen prompts to complete the transaction. Purchase a Visitor Card To purchase a visitor card Select Purchase Visitor Card from the on-screen menu. NOTE: The actual verbiage of this prompt is determined by the host configuration. Follow the on-screen prompts to complete the transaction. Check Account Balance To check account balance Select Check Account Balance from the on-screen menu. Follow the on-screen prompts to complete the transaction. PRINTED APRIL 14, 2011 13 AC3100 MANAGER CARD FUNCTIONS AC3100 MANAGER C ARD F UNCTIONS Certain Cards can be configured as Manager Cards in BbTS. Inserting/removing a valid Manager Card when the AC3100 is in the idle mode (not in a transaction sequence), displays the manager card menu. Manager functions: Display/print transaction totals This option displays and prints transaction totals. It is intended to be used to create a local Audit report on the transactions each time the bill box is emptied or swapped out with an empty one. When totals display on the LCD, the manager has the option of clearing the interval totals. If the bills are being removed, it is recommended to clear the totals and attach a copy of the Audit printout with the bills for later audit. These totals can be displayed/printed and not cleared if desired. If multiple copies of the audit printout are desired, the totals can be displayed/printed several times and only clearing them the last time. Terminal setup This option is used to adjust the display brightness and the volume of the tones. Display device status information This option displays the AC3100 status information. The display includes information on the communication status with the host (on-line of off-line, etc.), any out-of-service conditions and status of the printer, bill validator, and card dispenser. Perform diagnostic functions This option is used to perform diagnostic functions on the LCD, card dispenser, printer, local alarm and door switch, and the keypads. PRINTED APRIL 14, 2011 14 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 AC3100 MAINTENANCE AC3100 maintenance tasks include: • Fill the Card Dispenser (page 1-15) • Empty the Bill Box (page 1-15) • Install the Paper Roll (page 1-17) • Replace the Power Supply Fuses (page 1-20) NOTE: The AC3100 contains a configurable local alarm. The alarm sounds when the door is opened without an authorized manager card swipe, see: AC3100 Components (page 1-21). Fill the Card Dispenser To fill the card dispenser Remove the metal H shaped weight from the card dispenser chute. For location, see: AC3100 Components (page 1-21). Load the cards into the card dispenser chute, and then replace the metal weight on top of the stack of cards. NOTE: Use only .030" PVC cards. The dispenser can hold approximately 190 cards. Empty the Bill Box Bills can only be removed from the Bill Validator by removing the Bill Box. For location, see: AC3100 Components (page 1-21). NOTE: Although the Bill Validator can hold up to 1000 bills, a maximum currency value can also be set. Once either limit is reached, cash deposits are no longer allowed. There are two keys used with the Bill Box: • A042 Key - Opens the Bill Box. (All Keyed alike) • A043 Key - Releases the Bill Box from the Bill Validator. (All keyed alike) PRINTED APRIL 14, 2011 15 AC3100 M AINTENANCE To empty the Bill Box With the enclosure open, insert the A043 key, and then turn key counter-clockwise to unlock the Bill Box from the Bill Validator. Press the two wire releases to disengage the latch, and then pivot the Bill Box away from the Bill Validator, by gently pulling at the top. The bill box can now be lifted straight up to disengage the hinge pins from the Bill Validator bracket. The wire releases free the Bill Box from the cassette. Wire Release Wire Release Pivot the Bill Box away from the door Figure 1-8 Bill Box Removal Insert the A042 key into the lock located in the rear of the Bill Box, and then turn counter-clockwise. Open the Bill Box door. Remove the currency. To reinstall, engage pivot pins, and then push forward until the Bill Box latches. PRINTED APRIL 14, 2011 16 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 Install the Paper Roll NOTE: When installing a paper roll for the first time, the tape securing the print head to the printer body must be removed and discarded. The tape protects the print head from damage during shipping. A Low Paper sensor located on the printer assembly alerts the administrator when this condition occurs. This information can be sent to a log file. The paper can be changed without access to the cash. The AC3100 printer uses thermal paper with the following specifications: • 80mm-wide • 20# or 21# paper weight • Maximum 6” OD • 1” ID core • Thermally coated side OUT Table 1-3: Paper Roll Sources Supplier Part Number Phone Number(s) Communication Paper Ltd. Inc. CP-80715 (Superior Grade 20#) phone (888) 327-2737 fax (908) 713-6313 Current Components TP80-6-354 (800) 342-9798 Max International T2318645-8 (800) 233-0222 ext. 105 Printing Technologies TTP7080 (800) 428-3786 Swecoin SWE80-150 (401) 734-6709 PRINTED APRIL 14, 2011 17 AC3100 M AINTENANCE To install the paper roll Turn the new paper roll as shown. Insert the paper roll into the printer with the temperature-sensitive side up. temperature sensitive side up Figure 1-9 AC3100 Paper roll Remove a full turn of the paper from the new paper roll. NOTE: This is important since the outer end of the paper is usually fixed to the roll with glue or self-adhesive substance that can cause a paper jam or print head damage. Cut the paper off at a 70 to 90 degree angle as shown. Figure 1-10 Paper Roll Cut-off NOTE: If the paper is cut in the opposite direction to what is shown in Figure 1-10, the printer may not detect the paper. Insert the paper through the paper entry opening at the back of the printer. The printer feeds, cuts and ejects a printout, and then goes on-line. PRINTED APRIL 14, 2011 18 AC3100 INSTALLATION GUIDE D OCUMENT 1 3 5 3 REV 01 feed the paper place over the end of the spool to secure Figure 1-11 Paper Entry Opening PRINTED APRIL 14, 2011 19 COMPONENT REPLACEMENT COMPONENT REPLACEMENT Replace the Power Supply Fuses WARNING: To eliminate risk of electrical shock or injury, it is recommended that the main 115VAC supply or breaker be turned off and the power switch on the AC3100 power supply is turned off! The AC3100 uses a single 1A 250v fuse for input power and three 3A 250V fuses for output power. The power input fuse is located directly below the on/off power switch. The output fuses are located across the bottom of the power supply module. The fuse on the left is for +12v output which supplies power to the electronics board, LCD, and mag-stripe reader. The center fuse is +24v power for the printer. The right fuse is +24v power for the bill validator and card dispenser. If a peripheral is not functioning, check the fuse and replace if necessary. Power Supply 3AG 1A 250V 3AG 3A 250V 3AG 3A 250V 3AG 3A 250V CONTROLLER/LCD & MAG-STRIPE READER PRINTER Bill Validator & Card Dispenser Figure 1-12 AC3100 Fuse Locations FIELD REPLACEMENT COMPONENTS When ordering replaceable parts for the AC3100, refer to the table below and contact Blackboard. Table 1-4: AC3100 Replacement Parts MSC Part Number Description MSC/BVACUS Replacement Bill Validator for United States currency MSC/BVACCA Replacement Bill Validator for Canadian currency MSC/RPAC Replacement Printer MSC/CDAC Replacement Card Dispenser MSC/RDRAC2 Replacement Contactless/Mag-stripe reader PRINTED APRIL 14, 2011 20 COMPONENT REPLACEMENT SIREN Card Reader Tamper Switch (Sets off Siren) Printer Assembly Paper Roll Spool Bill Box Card Dispenser Figure 1-13 AC3100 Components PRINTED APRIL 14, 2011 21 COMPONENT REPLACEMENT LOCK LUBRICATION • The AC3100 requires lubrication of the lock mechanism • Apply lubricant anytime an increase in torque is required to turn the lock • Lubricate the threaded rod on the lock mechanism with a silicone-based grease (comparable to SIL-GLYDE) • Apply the grease to the first 3 threads at the end of the rod • Lubricate the lock cylinder with a spray type lubricant (Teflon based such as Tri-Flow) • Close the door of the AC3100 to avoid any overspray coming into contact with electrical components • Position the spray nozzle close to the lock cylinder, and then apply a small amount • Install the key in the lock cylinder, and then turn several times to disperse the lubricant • Wipe off any excess from the lock handle and surrounding area • Lubricate the hinge with a spray type lubricant (Teflon based such as Tri-Flow) • Position the spray nozzle close to the hinge and apply a small amount, avoid any overspray coming into contact with electrical components Lubricate lock with Tri-Flow or similar lubricant Lubricate lock screw with SIL-GLYDE or similar lubricant Figure 1-14 Lock Lubrication PRINTED APRIL 14, 2011 22 AC3 100 F EATURES & SPECIFICATIONS AC3100 F EATURES & SPECIFICATIONS AC3100 Features: • Accepts unattended deposits • Purchase and dispense visitor cards • Check account balances • Print receipts • 8.4” color LCD display • Configurable text colors, background colors, and color banners • Optionally charge a fee for card purchases • Configurable to accept $1, $5, $10, $20, $50, $100 bill denominations • Accepts Credit cards (Universal Edition only) • Local audit report capability • Remote software downloads • Lockable bill boxes (load printer paper or cards without access to cash) • Advanced Encryption Standard (AES) for IP • Local tamper siren • Contact your Account Manager for a template to design a front cover decal used for marketing AC3100 Specifications: Physical Size: 18"W x 21"H x 9.775"D (10.145"D including bezel) 80 pounds Input Power: 120 VAC Max @ 60Hz, 1.5 amp max Operating: Temperature: 0 to +50 degrees Celsius Relative Humidity: 0 to 96 percent, non-condensing Altitude: 0 - 10,000 feet Non-Operating: Temperature: -20 to +70 degrees Celsius Relative Humidity: 0 to 95 percent, non-condensing Altitude: 0 - 35,000 feet NOTE: This device contains an integrated lithium battery. There is a risk of fire if the battery is replaced with an incorrect type. Proper disposal of a used battery is essential. Please follow the manufacturer’s instructions. PRINTED APRIL 14, 2011 23 BBTS UNIVERSAL EDITION CHANGES BBTS UNIVERSAL EDITION CHANGES When converting an AC3100 from Unix Edition to Universal Edition, the following items are affected: • Privileges - Do not function the same as they do in Unix Edition, every cardholder that uses a reader in a particular Profit Center is required to use the same fund Autostored Value Order • Plan Level Discounts - Do not currently work in UE • Shadow Accounts - Do not currently work in UE PRINTED APRIL 14, 2011 24
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : jramirez Create Date : 2011:04:14 08:36:25Z Modify Date : 2011:04:29 09:36:28-07:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : FrameMaker 9.0 Metadata Date : 2011:04:29 09:36:28-07:00 Producer : Acrobat Distiller 10.0.0 (Windows) Format : application/pdf Title : 1353_AC3100_Installation.book Creator : jramirez Document ID : uuid:eb3b6e20-a4c9-4fde-8156-780786854d51 Instance ID : uuid:37dfafc7-60a5-48a5-896e-59cc1d0da9e0 Page Mode : UseOutlines Page Count : 28EXIF Metadata provided by EXIF.tools