Transact Campus MF4100X004 Multi-Function Reader User Manual 1295 MF4100 InstallAdmin

Blackboard Inc. Multi-Function Reader 1295 MF4100 InstallAdmin

User Manual

DRAFTMF4100Installation Guide
DRAFTThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Part 15.21: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.NOTE:  The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.This equipment complies with the FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.This Class B digital apparatus complies with Canadian ICES-003Cet appareill numérique de la classes B est conform à la norme NMB-003 du Canada
DRAFTContentsPRINTED N OVEMBER 3, 2009                   I1MF4100 INSTALLATION GUIDE1 Overview3 VESA Mounting Bracket Overview3 Mounting Options3 Screw Positions4 Assembly Details5 Mount the MF41006 Wall Mount Installation6 Attended Wall Mount Installation8 Unattended Wall Mount Installation10 Table Top Mount Installation10 Table Top Mount With The VESA Mounting Bracket12 Table Top Mount Without The VESA Mounting Bracket13 MF4100 Features and Specifications
DRAFTFIGURESPRINTED N OVEMBER 3, 2009                   IIFigure 1-1 Multi-Function Reader MF4100..................................................................1Figure 1-2 Cat-5 Cable and Power Supply ..................................................................2Figure 1-3 MF4100 Hardware Kit ................................................................................2Figure 1-4 VESA Bracket.............................................................................................2Figure 1-5 VESA Bracket Screw Position - Attended ..................................................3Figure 1-6 VESA Bracket Screw Position - Unattended ..............................................4Figure 1-7 VESA Bracket Assembly Details ................................................................4Figure 1-8 Wall Mount Options ....................................................................................5Figure 1-9 Table Top Mount Options............................................................................5Figure 1-10 VESA Bracket - Attended Wall Mount ........................................................6Figure 1-11 MF4100 Cable Ports ..................................................................................7Figure 1-12 Attended Wall Mount VESA Bracket Orientation........................................7Figure 1-13 Reader Secured to Pivot Plate - Attended Wall Mount...............................8Figure 1-14 VESA Bracket - Unattended Wall Mount....................................................8Figure 1-15 Unattended Wall Mount VESA Bracket Orientation....................................9Figure 1-16 VESA Bracket Rubber Feet......................................................................10Figure 1-17 Table Top Mount - With VESA Bracket Cable Route................................11Figure 1-18 Reader Rubber Feet Installation Locations ..............................................12Figure 1-19 Table Top Mount - No VESA Bracket Cable Route ..................................12
DRAFTMULTI-FUNCTION READER MF4100 INSTALLATION GUIDEDOCUMENT 1295   REV 01PRINTED N OVEMBER 3 ,  2 0 0 9                     1-1MF4100 INSTALLATION GUIDEOVERVIEWThe Blackboard MF4100 Multi-function reader incorporates both contactless and magnetic stripe reader capabilities, and can function as a: • Copy Reader• Laundry Reader• POS TerminalThe MF4100 supports full video and audio playback allowing for a rich video experience for:• Advertising• Alerts and notifications• Other special messages via a full color touch screenFor MF4100 features, see: MF4100 Features and Specifications  (Page: 13).Figure 1-1 Multi-Function Reader MF4100OBJECTIVESAfter reading this guide you can:• Wall mount the MF4100 •Table top mount the MF4100
DRAFTOVERVIEWPRINTED N OVEMBER 3, 2009                   1-2WHAT’S INCLUDEDA hardware kit is provided with a security plate, rubber feet, and screws to aid in mounting the unit.Figure 1-2 Cat-5 Cable and Power SupplyFigure 1-3 MF4100 Hardware KitFigure 1-4 VESA BracketCat-5 Cable Wall Mount Power SupplySecurity PlateScrew kitRubber Feet
DRAFTMULTI-FUNCTION READER MF4100 INSTALLATION GUIDEDOCUMENT 1295   REV 01PRINTED N OVEMBER 3 ,  2 0 0 9                     1-3VESA MOUNTING BRACKET OVERVIEWThe MF4100 Multi-Function Reader ships with a VESA style mounting bracket. The mounting bracket is optional, but simplifies installation on vertical and horizontal surfaces. The VESA mounting bracket is adjustable to allow the MF4100 to be positioned at different angles.Mounting OptionsThe VESA Mounting Bracket can be mounted in the following ways:• Wall mount•    Onto an electrical gang box (attended or unattended)•    Directly to a wall (use suitable anchors)• Table top mount•    With VESA bracket (fixed 15 degree or adjustable angle)•    Without VESA bracketThe holes in the center of the base and pivot plate allow cables to be routed out of the assembly.Screw PositionsThe VESA bracket has provisions for Attended or Unattended mounting positions. To use in attended locations, the top pivot plate can be used in any position by placing the lock screws in the position shown below.Figure 1-5 VESA Bracket Screw Position - Attended
DRAFTVESA MOUNTING BRACKET OVERVIEWPRINTED N OVEMBER 3, 2009                   1-4For Unattended use, the mounting position can be fixed by placing the lock screws in the position shown below. This locked position conceals the cables from sight, and secures them from being tampered with.Figure 1-6 VESA Bracket Screw Position - UnattendedAssembly DetailsFigure 1-7 VESA Bracket Assembly DetailsBase extensionsLocking screwsPivot PlateBaseCable Holes
DRAFTMULTI-FUNCTION READER MF4100 INSTALLATION GUIDEDOCUMENT 1295   REV 01PRINTED N OVEMBER 3 ,  2 0 0 9                     1-5MOUNT THE MF4100MF4100 MOUNTING OPTIONS:•    Wall Mount Installation  (Page: 6)•    Table Top Mount Installation  (Page: 10)Figure 1-8 Wall Mount OptionsFigure 1-9 Table Top Mount OptionsUnattended wall mountAttended wall mountFixed 15 degree angle Adjustable angle No VESA bracket
DRAFTWALL MOUNT INSTALLATIONPRINTED N OVEMBER 3, 2009                   1-6WALL MOUNT INSTALLATIONThe VESA mounting bracket allows for two wall mount installation options:•Attended Wall Mount Installation  (Page: 6)•Unattended Wall Mount Installation  (Page: 8)Attended Wall Mount Installation1Find a location on a single gang box to mount the MF4100.Ensure there is enough clearance for the operator to access the touchscreen and swipe cards.2Remove the two base extensions by removing the 4 screws (1/8” Pin hex driver).See: VESA Bracket Assembly Details  (Page: 4).3Place the two locking screws in the position that allows the tilt plate to pivot (1/8” Pin hex driver).See: VESA Bracket Screw Position - Attended  (Page: 3).4Route the required cables through the VESA bracket cable hole, and then the pivot bracket hole.Note the orientation of the VESA bracket to the wall.Figure 1-10 VESA Bracket - Attended Wall MountNote: The pivot plate attaches to the bottom of the MF4100 reader.5Attach the mounting base to the gang box using the two #6-32 pin hex screws provided in the hardware kit.6Install cables to the connectors of the MF4100.Route CablesPivot Plate
DRAFTMULTI-FUNCTION READER MF4100 INSTALLATION GUIDEDOCUMENT 1295   REV 01PRINTED N OVEMBER 3 ,  2 0 0 9                     1-7The MF4100 can be powered using the +12 Volt wall mount power supply (included), or Power Over Ethernet (POE) switch. The power supply requires a dedicated 110 VAC outlet. POE provides power through the network cable, and reduces cable clutter. A CAT-5 cable must be connected between the POE switch to the RJ-45 connector on the MF4100 labeled Network, see the diagram below. When providing power with POE, the maximum LAN cable length must not exceed 100 meters.Figure 1-11 MF4100 Cable Ports7Place the security plate onto the MF4100, and then route the cables through the plate opening.Note the orientation of the VESA bracket to the security plate.Figure 1-12 Attended Wall Mount VESA Bracket Orientation8Place the MF4100 assembly on the pivot plate, and then secure using four M4 x 6mm machine screws provided in the hardware kit.Power SupplyNetwork/POE Copy  Print/LWCFGAUX1/BridgeAUX2/LCMConfigUSBExpansionSecurity plate
DRAFTWALL MOUNT INSTALLATIONPRINTED N OVEMBER 3, 2009                   1-8Figure 1-13 Reader Secured to Pivot Plate - Attended Wall Mount9Position the pivot plate to the desired angle, and then tighten the 2 locking screws (1/8” pin hex driver).Unattended Wall Mount Installation1Find a location on a single gang box to mount the MF4100.Ensure there is enough clearance for the operator to access the touchscreen and swipe cards.2Remove the two base extensions by removing the 4 screws (1/8” pin hex driver).See: VESA Bracket Assembly Details  (Page: 4).3Route the required cables through the VESA bracket cable hole, and then the pivot bracket hole.Note the orientation of the VESA bracket to the wall.Figure 1-14 VESA Bracket - Unattended Wall MountNote: The pivot plate attaches to the bottom of the MF4100 reader.Route CablesPivot Plate
DRAFTMULTI-FUNCTION READER MF4100 INSTALLATION GUIDEDOCUMENT 1295   REV 01PRINTED N OVEMBER 3 ,  2 0 0 9                     1-94Attach the mounting base to the gang box using the two #6-32 pin hex screws provided in the hardware kit.5Install cables to the connectors of the MF4100.See: MF4100 Cable Ports  (Page: 7).6Place the security plate onto the MF4100, and then route the cables through the plate opening.Note the orientation of the VESA bracket to the security plate.Figure 1-15 Unattended Wall Mount VESA Bracket Orientation7Place the MF4100 assembly on the pivot plate, and then secure using four M4 x 6mm machine screws provided in the hardware kit.8Position the pivot plate to the desired angle, and then tighten the 2 locking screws (1/8” pin hex driver).Security plate
DRAFTTABLE TOP MOUNT INSTALLATIONPRINTED N OVEMBER 3, 2009                   1-10TABLE TOP MOUNT INSTALLATIONMF4100 table top mounting installation options:•Table Top Mount With The VESA Mounting Bracket  (Page: 10)•Table Top Mount Without The VESA Mounting Bracket  (Page: 12)Table Top Mount With The VESA Mounting Bracket1Find a location on a table or elsewhere to mount the MF4100.Ensure there is enough clearance for the operator to access the touchscreen and swipe cards.2Install the rubber feet provided in the hardware kit to each corner of the base extensions.The rubber feet are self-adhesive. Use the holes in the base extension to center each foot.Figure 1-16 VESA Bracket Rubber Feet3Route the required cables through the VESA bracket cable hole, and then the pivot bracket hole.4Install cables to the connectors of the MF4100.See: MF4100 Cable Ports  (Page: 7).5Place the security plate onto the MF4100, and then route the cables through the plate opening.Rubber Feet
DRAFTMULTI-FUNCTION READER MF4100 INSTALLATION GUIDEDOCUMENT 1295   REV 01PRINTED N OVEMBER 3 ,  2 0 0 9                     1-11For a fixed 15 degree angle, install the MF4100 so the security plate is located near the hinge of the VESA mounting bracket. Place the locking screws in the unattended position.  See: VESA Bracket Screw Position - Unattended  (Page: 4)  For an adjustable angle, install the MF4100 so the speaker opening is located near the hinge of the VESA mounting bracket. Place the locking screws in the attended position. See: VESA Bracket Screw Position - Attended  (Page: 3)Figure 1-17 Table Top Mount - With VESA Bracket Cable Route6Secure the VESA bracket using four M4 x 6mm machine screws provided in the hardware kit.7Tighten the 2 locking screws (1/8” pin hex driver).Security plate
DRAFTTABLE TOP MOUNT INSTALLATIONPRINTED N OVEMBER 3, 2009                   1-12Table Top Mount Without The VESA Mounting Bracket1Find a location on a table or elsewhere to mount the MF4100.Ensure there is enough clearance for the operator to access the touchscreen and swipe cards.2Install the rubber feet provided in the hardware kit to each corner of the MF4100 plastic bottom cover.   The rubber feet are self-adhesive. The bottom cover has round depressions in the plastic to locate the rubber feet. Install a rubber foot at each of the four corners.Figure 1-18 Reader Rubber Feet Installation Locations3Install the required cables to the connectors of the MF4100.See: MF4100 Cable Ports  (Page: 7).4Place the security plate onto the MF4100, and then route the cables through the opening.Figure 1-19 Table Top Mount - No VESA Bracket Cable Route5Secure the security plate onto the MF4100 using two M4 x 6mm machine screws provided in the hardware kit.Rubber feet (4)Security Plate
DRAFTMULTI-FUNCTION READER MF4100 INSTALLATION GUIDEDOCUMENT 1295   REV 01PRINTED N OVEMBER 3 ,  2 0 0 9                     1-13MF4100 FEATURES AND SPECIFICATIONSFEATURES:• Host communications via 10/100 Base-T ethernet (IP) or 802.11 b/g wireless• Encrypted and authenticated IP communications • VESA mounting bracket for table top or wall mount installation• Display visible in all light conditions with adjustable backlight level• Displays balance, account warnings, and other messages after transactions• 5.7” VGA TFT-LCD panel• Configuration via touchscreen/display, CONFIG port or web server• Touchscreen configuration access can be disabled• Adjustable volume settingSPECIFICATIONS:Physical Size:    9.0” W x 5.5”H x 2.21” D (without bracket) 1.7 poundsInput Power:   12 VDC 750 mA max (max 9W) - DC Input Voltage36-57 VDC - POE Input VoltageOperating :   Temperature: 0 to + 60 degrees Celsius Relative Humidity: 0 to 95 percent, non-condensing Altitude: 0 -10,000 feetNon-Operating:   Temperature:-20 to + 70 degrees Celsius Relative Humidity: 0 to 95 percent, non-condensing Altitude: 0 - 35,000 feet