Transtek Medical Electronics AW8001-LS Bluetooth Module User Manual Rev1
Guangdong Transtek Medical Electronics Co.,Ltd Bluetooth Module Rev1
Contents
User Manual Rev1
Guangdong Transtek Medical Electronics Co.,Ltd AW8001 Bluetooth 4.0 module Specification Version 1.0 2013-7-25 Guangdong Transtek Medical Electronics Co.,Ltd 1.1 Introduction The AW8001 Module is designed to be used in conjunction with an external microcontroller running the application. The AW8001 integrates acomplete PHY, Link Controller and Host single mode Bluetooth low energy subsystem and features a simple SPI based interface to the application microcontroller. Qualified profiles, APIs and example application are provided as part of the μBlue SDK which is easily portable to a range of different application microcontrollers. This system segmentation allows the AW8001 to be used with the best-fit microcontroller for a specific application as well as ease integration and end product qualification as application and protocol stack does not share the same microcontroller. 1.2 Features • • • • • • • • • • • • • Bluetooth Specification v4.0 compliant single mode low energy solution Complete PHY, Link Controller and Host subsystem Profiles and example applications provided in μBlue SDK Cost and power optimized for slave operation Simple SPI based Application Controller Interface (ACI) Full Link Controller and Host security 1.9 to 3.6V operation Linear voltage regulator Step-down DC/DC voltage regulator providing up to 20% peak current reduction Sub 14mA peak current with linear voltage regulator Supports sub 10μA average current operation Battery voltage monitor Temperature sensor 1.3 APPLICATIONS • • • • • • • • Sports and fitness sensors Healthcare and medical sensors Continua™ Version Two certified products Remote controls Watches Mobile phone peripherals Automation sensors Proximity tags Guangdong Transtek Medical Electronics Co.,Ltd 2.1 Product Information AW8001 is a BT4.0 Module , It’s main physical features are the Bluetooth low energy PHY and the Bluetooth low energy stack that handles the link controller and host stack. It also includes additional analog sub-systems needed for the Bluetooth low energy operation, such as power management and several oscillator options. AW8001 block diagram AW8001 has on-chip non-volatile memory for storing service configurations. This on-chip storage lets you select and combine the necessary services for your application, reducing the requirements on your application controller for handling all real-time operations related to the Bluetooth low energy communication protocol. AW8001 includes a power supply voltage monitor and a temperature sensor that further reduces the requirements to the application controller. These features are accessible through the Application Controller Interface (ACI). AW8001 also offers an optional output signal that is activated before the radio becomes active. This timing signal enables you to control the peak current drain of your application, avoiding overload of your power supply (for most applications this is usually a small battery). You can also use this timing signal to control the application circuitry, avoiding noise interference when the AW8001 radio is operating. A separate serial interface (UART) gives you access to the Bluetooth low energy Direct Test Mode (DTM).This interface is used to control the Bluetooth low energy radio (RF PHY) and is supported by commercially available Bluetooth test equipment used for Bluetooth qualification. This serial interface also enables you to test radio performance and to optimize your antenna. Guangdong Transtek Medical Electronics Co.,Ltd 2.2 Operating conditions The operating conditions are the physical parameters that nRF8001 can operate within. 2.3 Digital I/O signal levels The digital I/O signal levels are defined Table. The operating conditions are: VDD = 3.0V, TA = 40oC to +85oC (unless otherwise noted). 2.4 Radio characteristics nRF8001 electrical characterization is defined in Table . The operating conditions are: VDD = 3.0V, TA = 40oC to +85oC (unless otherwise noted). Guangdong Transtek Medical Electronics Co.,Ltd 3.1 Mechanical Information 3.2 PIN Information VCC MOSI SCK /REQN MISO /RDYN NC RESET GND Guangdong Transtek Medical Electronics Co.,Ltd 3.3 Module Installation Step1: Connect the Module to the connector , this connector can be a PCB or Pin header or another , see following picture Step2: Connect the Module PCBA to the Main PCBA , see following picture Step3: Install the Main PCBA to the Product ,see following picture Caution: When install the module , you must pay attention to the temperature of the soldering iron(the soldering iron should be connect to Ground ) , the temperature should be set at about 380℃ ; you must pay attention to the electrostatic too , take action to avoid electrostatic . And you must avoid short circuit when you connect the module. Module FCC ID: OU9AW8001-LS Guangdong Transtek Medical Electronics Co.,Ltd Step4: The final Product, see following picture Make sure that the module is fixed in the host and does not allow users to replace or demolition. Guangdong Transtek Medical Electronics Co., Ltd Caution: Any changed or modifications not expressly approved by the party responsible for compliance could void the user`s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This device should be installed and must not be co-located or operating in conjunction with any other antenna or transmitter. The module in this product is labeled with its own FCC ID and the FCC ID is not visible when the module is installed inside another device. To satisfy FCC exterior labeling requirements, the following text must be placed on the exterior of the end product. Contains Transmitter Module FCC ID: OU9AW8001-LS
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : 09010 Create Date : 2013:07:26 13:02:58Z Modify Date : 2013:07:30 13:15:39+08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : 09010 Title : E:\Kelvin work file\project file\LS产品\TSF1235系列PCB的项目【GBF-1064BT系列】\AW8001模块\AW8001 datasheet.doc Creator Tool : pdfFactory Pro www.fineprint.com.cn Metadata Date : 2013:07:30 13:15:39+08:00 Producer : pdfFactory Pro 2.23 (Windows XP Chinese) Document ID : uuid:3dddef2e-fea6-4603-bc67-b45a2e3746e5 Instance ID : uuid:8c9010dd-be4b-482e-b0ac-62bcd456f768 Page Count : 8EXIF Metadata provided by EXIF.tools