Transtek Medical Electronics LS108-B06 Bluetooth body Scale User Manual LS406 B

Guangdong Transtek Medical Electronics Co.,Ltd Bluetooth body Scale LS406 B

User Manual

Download: Transtek Medical Electronics LS108-B06 Bluetooth body Scale User Manual LS406 B
Mirror Download [FCC.gov]Transtek Medical Electronics LS108-B06 Bluetooth body Scale User Manual LS406 B
Document ID2523346
Application IDRDx13j+bJeRPguMRW8Hofw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize101.88kB (1273538 bits)
Date Submitted2015-02-04 00:00:00
Date Available2015-02-04 00:00:00
Creation Date2013-05-09 08:44:28
Producing SoftwareAdobe PDF library 9.90
Document Lastmod2015-01-23 16:32:31
Document TitleLS406-B user manual
Document CreatorAdobe Illustrator CS5
Document Author: Shuting

version:1.0
User Manual
Bluetooth Body Scale
GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD
Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch Development
District, Zhongshan, Guangdong, 528437, China
TEL:86-760-88282982
www.transtek.cn
LS108-B6
Thank you very much for selecting the Transtek Bluetooth Body Scale
LS108-B6.
Please do read the user manual carefully and thoroughly so as to ensure
the safe usage of this product, and keep the manual well for further
reference in case you have problems.
Table of Contents
Table of Contents
Symbol Meaning
Symbol Meaning ......................................................................................................................... 2
Safety Information
Your Scale and Its Environment
Efficient Use of Your Scale
............................................................................................. 2
............................................................................................. 3
Overview
General Instructions ................................................................................................................. 4
Device Components ................................................................................................................. 4
List ............................................................................................................................................ 4
LED Display .............................................................................................................................. 5
Initial Start-Up
Insert the Batteries ................................................................................................................... 6
Install App and Pair-up .......................................................................................................... 7
Start Measuring
Select Measurement Unit .......................................................................................................... 8
Daily Measurement ................................................................................................................... 8
Data Management
Data Transmission .................................................................................................................... 9
Troubleshooting
Error Prompt ............................................................................................................................. 10
.................................................................................................................. 11
When Measuring
When Data Transmitting ........................................................................................................ 12
Specifications ............................................................................................................................ 13
Maintenance ............................................................................................................................... 14
Warranty ...................................................................................................................................... 14
FCC Regulations .......................................................................................................................... 15
Symbol Meaning
Safety Information
Symbol Meaning
The warning signs and symbols are essential to ensure your correct and safe use of
this product and protect you and others from injury. Please kindly find the meanings of the
warning signs and symbols, which you may encounter in the label and user manual, as
follows:
To prevent you from injury, please pay attention to the following Notice.
Small parts being inhaled or swallowed.
Potential allergic reactions to accessible materials used in the ME EQUIPMENT.
Contact injuries.
Symbol for “THE OPERATION
GUIDE MUST BE READ”
Symbol for “MANUFACTURER”
Use accessories, detachable parts and materials not described in the instructions for use.
The Bluetooth Combination Mark
Symbol for “COMPLIES WITH EU
REQUIREMENTS”
Symbol for “SERIAL NUMBER”
Symbol for “ENVIRONMENT
PROTECTION – Waste electrical
products should not be disposed of with
household waste. Please recycle where
facilities exist. Check with your local
authority or retailer for recycling advice”
A list of known devices or other sources that can potentially cause interference problems
(example 1 Heat from a fireplace or radiant heater. example 2 Moisture from a nebuliser
or steam kettle).
Symbol for “MANUFACTURE
DATE”
Symbol for “DIRECT CURRENT”
The effects of degraded sensors and electrodes, or loosened electrodes, that can degrade
performance or cause other problems.
The effects caused by pets, pests or children.
Efficient Use of Your Scale
Your Scale and Its Environment
To ensure your safety as well as the service life of your scale, please avoid using
the scale under the following circumstances:
Slippery floor such as tile floor
Jumping onto the platform immediately after bath or with wet hands
Near a cell phone or microwave oven
To ensure the accuracy of measurement, please follow below instructions when
you start measurement.
Place the scale on a flat, hard surface. Soft surface such as carpet will affect the
performance of the scale.
Start measurement at least two hours after Getting up or Dinning.
Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and
dinning.
Always start measurement in the same time slot and on the same scale located on the
same flat, hard surface.
Avoid storage in the following locations:
Where there is water
Where the device may be exposed to extreme temperatures, humidity, moisture, direct
sunlight, dust, or salt air
Where there is risk of shock or drop
Where you store chemicals or full of corrosive gases
Where in reach of the infants or children
Overview
Overview
General Instructions
Transtek Bluetooth Body Scale LS108-B6 applies SENSE ON technology. It’s not
necessary to turn on or turn off the scale, just stand on the scale for measurement.
It is delicate and trendy, convenience for using.
LED Display
Device Components
LED Display
Glass
UNIT and activation Button
Kilogram
Successful Bluetooth Connection
Pound
Data pending to
transmit to wireless wellness system
Battery Compartment
Stone
Sensor
List
1. Bluetooth Body Scale LS108-B6
2. Four AAA-size Batteries (1.5V each)
3. User Manual
Initial Start-Up
Power Supply
Battery Mode: 6V, 4 x AAA batteries
Battery Life: Approx. 200 days
(Battery capacity: 452 mAH. If measured three times per day, each measurement takes about 20s.
The current for measurement is about 45 mA , while the current when shutdown is about 20 uA.)
Insert the Batteries
Open the battery door in the back of the scale.
Insert the batteries (4 x 1.5V AAA) into the battery
compartment according to the polarity indications
marked inside the compartment.
* The digits “8888” will be shown on the LED.
Initial Start-Up
Install App and Pair-Up
With the advanced Bluetooth 4.0 technology applied, the mobile or portable equipments,
which are equipped with Bluetooth function in line with BLE Technical Specifications as
well as BLP Protocol established by global organization Bluetooth SIG, are capable to
receive your personal health data.
Just simply install the specially-designed app and pair up your scale with
your mobile or portable equipments. Then you may enjoy the comprehensive health
solution provided by Transtek.
Note: It is only available for the device which supports Bluetooth 4.0 technology.
Turn on Bluetooth and App. Make sure both are ON when pair-up is
proceeding.
Press and hold “UNIT” button in the back of the scale to start pair-up.
Close the battery door and wait until the digits
“0.0kg” are shown on the LED.
Symbol
and symbol
will be shown on the
LED alternatively, indicating pair-up is proceeding.
CAUTION
When the symbol “Lo” appears, the device will power off in four seconds. Then you shall replace with a
new set of batteries. Please replace all four batteries at the same time. Do NOT mix the old batteries with
the new one.
Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage.
Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries.
If SUCCEED, symbol
will be shown on the LED.
If FAIL, symbol “E1” will be shown on the LED.
Start Measuring
Select Measurement Unit
With batteries correctly installed, press “UNIT” button in the back of the scale to select
measurement unit. The default measurement unit is “kg”. You may press “UNIT”
button to choose among kilogram, pound and stone.
Data Management
Data Transmission
Once the Bluetooth Body Scale LS108-B6 is successfully
paired-up with your smartphone, please open the App and
turn on your Bluetooth. Keep smartphone and scale in
transmission distance. Step on the scale and take a
measurement. Once the measurement is finished the data
is automatically transferred to the app.
Daily Measurement
With original SENSE ON patent technology, the scale
will automatically switch on as you step on the platform
barefooted.
Stand still and keep full contact with the scale until the LED displays the weight and
stop blinking the unit.
The symbol
will disappear after successful data
transmission, and you may check your personal
health data stored in your smartphone.
If the data transmission fails, the symbol
will
remain. The pending measurement data will be
temporarily kept in the scale and transmitted to your
smartphone when next measurement is complete.
When your scale is successfully paired with your smartphone and the Bluetooth is ON,
it will process data transmission automatically.
(Please refer to Data Transmission for more details.)
Successful Bluetooth
Connection
Data ready to transmit to
the App:
-If SUCCEED, the symbol
disappears;
-If FAIL, the symbol
remains.
Note: Whether the data transmission is successful ,
the device will shut down automatically 15 seconds later.
Troubleshooting
Troubleshooting
Error Prompt
Error
When Measuring ...
Description
Overload. The device will
power off.
Low Battery. The device
will power off in four
seconds.
Failure of pairing up your
scale with your smartphone.
Or failure of activation.
There has data doesn’t
upload. (The notebook
icon will be displayed.)
10
Solution
Problem
Stop using this scale for
measurement.
Replace all four batteries at the
same time. Please purchase the
authorized batteries for
replacement.
Please check below items:
-Bluetooth is ON.
-App is ON.
-Both devices are within the
transmission distance of Bluetooth.
Root Cause
Batteries not yet installed.
Install the batteries.
(Please refer to Insert the
Batteries)
Worn batteries.
Replace all four batteries at the
same time. Please purchase the
authorized batteries for
replacement.
Low battery.
Replace all four batteries at the
same time. Please purchase the
authorized batteries for
replacement.
No display on
LED when the
device powers on.
The device
powers off
automatically.
Solution
Upload the data.
11
Troubleshooting
Specifications
Specifications
Product Name
When Data Transmitting ...
Problem
Root Cause
Bluetooth is OFF.
Solution
Turn ON the Bluetooth via
“Setting >> General >> Bluetooth”.
Dimension
Scale: 320x320x25mm (Approximately)
Net Weight
Approximately 1.98kg ( Excluding the dry cells)
Display
Data transmission
failed.
App is OFF.
Press the icon to turn ON your
app.
Measurement Unit
Measurement Range
Out of range of Bluetooth
transmission.
Place your smartphone closer
to the scale.
Bluetooth Body Scale (LS108-B6)
Division
Accuracy
Working Environment
Storage Environment
Power Source
Digital LED
V.A.: 75x41mm
Kilogram / Stone/Pound
5kg to 180kg / 0st: 11lb to 28st: 5lb / 11lb to 397lb
0.1kg; 0.2lb; 0.2 lb/1lb (≥20st)
5-50kg: ±0.3kg;
100-150kg: ±0.5kg;
50-100kg: ±0.4kg;
150-180kg:±0.7kg
Temperature: 5℃ to 40℃
Humidity: 15% RH to 93%RH
Atmospheric pressure: 70kPa to 106kPa
Temperature: -20℃ to 60℃ Humidity: ≤93% RH
Atmospheric pressure: 50kPa to 106kPa
6V (Four AAA-size Batteries)
Auto-ON
SENSE ON technology
Auto-OFF
About 10 seconds while showing 0.0
About 15 seconds after the weight data is locked
Accessories
Mode of Operation
1. Four AAA-size Batteries
2. User Manual
Continuous Operation
About the Accuracy of This Product
This product passes strict inspection before delivery and therefore its accuracy is guaranteed by the manufacturer.
Please refer to the above table for the descriptions on accuracy.
WARNING: No modification of this equipment is allowed.
12
13
Maintenance
Maintenance
When carrying out usual maintenance, please ensure practice of the following Do’s and
Don’ts:
DO use a dry soft cloth to wipe the dust.
DO use a wet soft cloth, dipped into water and wrung out, to wipe the dirt. Then use a
dry soft cloth to dry up the device.
DON’T wash the device with water or immerse it in water.
DON’T use propellant, abrasive or other chemicals to wipe the dirt in avoidance of
discolor or malfunction.
DON’T disassemble this device. If you have any problems, please contact Transtek.
(Please refer to Warranty for contact information)
Warranty
Transtek warrants its products free of defects in materials and workmanship in normal
use for a period of TWO years from the date of retail purchase.
This warranty does NOT cover damages caused by misuse or abuse, including but not
limited to:
Failure caused by unauthorized repairs or modifications;
Damage caused by shock or drop during transportation;
Failure caused by improper operation inconsistent with the instructions stated in this user
manual;
Malfunction or damage from failure to provide the recommended maintenance;
Damage caused by improper use of power supply.
Should this device require maintenance (or replacement at our option) under warranty,
please deliver the original package to GUANGDONG TRANSTEK MEDICAL
ELECTRONICS CO., LTD prepaid. Please return the store receipt (with the retail
purchase date) and a note with reasons to return on it as well.
GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD
Zone A, 5/F., Investment Building, No. 12 Huizhan East Rd., Torch Development District,
Zhongshan, 528437, Guangdong, China
Tel: 86-760-88282982
Website: http://www.transtek.cn
14
FCC Regulations
FCC Regulations
Contains FCC ID: OU9LS108-B06
FCC User Guide Information
Radio Frequency Interface Requirements - FCC
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna;
Increase the separation between the equipment and receiver;
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected;
Consult the dealer or an experienced radio / TV technician for help.
Radio Transmitters (Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC RF Exposure Guidelines
Safety Information
Reducing RF Exposure - Use Properly
Only operate the device in accordance with the instructions supplied.
This device complies with FCC radiation exposure limits set forth for an uncontrolled
environment.
15

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00
Format                          : application/pdf
Title                           : LS406-B  user manual
Description                     : User Manual
Creator                         : Shuting
Creator Tool                    : Adobe Illustrator CS5
Create Date                     : 2013:05:09 08:44:28+08:00
Modify Date                     : 2015:01:23 16:32:31+08:00
Metadata Date                   : 2015:01:23 16:32:31+08:00
Thumbnail Width                 : 40
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 2544 bytes, use -b option to extract)
Original Document ID            : uuid:9E3E5C9A8C81DB118734DB58FDDE4BA7
Document ID                     : xmp.did:699E7D9841B8E211BB1CBF23DB8308F5
Instance ID                     : uuid:9ac49c71-fb86-41fb-9629-71420b323b4b
Rendition Class                 : proof:pdf
History Action                  : converted, saved, converted, converted, saved, converted, saved, converted, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:D07F11740720681191099C3B601C4548, xmp.iid:FC7F117407206811B628E3BF27C8C41B, xmp.iid:FD7F117407206811B628E3BF27C8C41B, xmp.iid:0CC3BD25102DDD1181B594070CEB88D9, xmp.iid:03E540664A3DDD11BD33D3EB8D3A1068, xmp.iid:6D6AE2A5723EDD11A6F1BABF7C5A7A51, xmp.iid:20383BFEA441DD11A6AECB58D53C8B28, xmp.iid:096F577ABE41DD11A6AECB58D53C8B28, xmp.iid:AB13E990200911689FE8CB9EA85C5459, xmp.iid:95D9A2DF7848DD11BB47877F8DDF9079, xmp.iid:F87F117407206811B34B80FC905F8DB1, xmp.iid:FE7F11740720681197A5C6DA8C2593EE, xmp.iid:FF7F11740720681197A5C6DA8C2593EE, xmp.iid:D5E97F3291E4DE11831BCC4BA24AAFD8, xmp.iid:3E09327B1FEADE119648D46DE661B201, xmp.iid:A8F46C6799EBDE118B29BF0F76361FFD, xmp.iid:233794C82A12DF11A1FB8DE093AEEF16, xmp.iid:E9171D43F3ABDF119F67BD126A85E7C0, xmp.iid:ED171D43F3ABDF119F67BD126A85E7C0, xmp.iid:A98329CBEEDCDF119F6AFE1DA0EB4A56, xmp.iid:F0D7C34F6BE9DF11BB38870380B6B2A6, xmp.iid:3097A67DCCEADF11AC9EC8ACF64A7DDE, xmp.iid:9550DF26AFEBDF119A34BB36D9091C95, xmp.iid:91B2A8E3B31EE0118388C60B75F0B421, xmp.iid:C66F62307E1FE011B297ADA3E90C4992, xmp.iid:32111635E540E211A2A3C2ACD38E298D, xmp.iid:D8BE93E0064BE211992AB2AA5473309D, xmp.iid:925B3A1E5351E211BB2AA5B5C8B3A954, xmp.iid:119378523FB8E2119103F28CE45EF15D, xmp.iid:0D2DAF963FB8E211B953FD11DEEDFEF3, xmp.iid:699E7D9841B8E211BB1CBF23DB8308F5
History When                    : 2008:04:17 14:19:10+05:30, 2008:05:22 14:51:08-07:00, 2008:05:22 15:15:38-07:00, 2008:05:28 17:07:17-07:00, 2008:06:18 22:24:35+07:00, 2008:06:19 20:31:09-07:00, 2008:06:24 13:29:32+08:00, 2008:06:24 15:24:18+08:00, 2008:06:26 06:04:07-07:00, 2008:07:02 13:54:46-07:00, 2008:07:21 16:58:27+05:30, 2008:09:05 04:29:47-07:00, 2008:09:05 04:30:01-07:00, 2009:12:09 17:43:05+08:00, 2009:12:16 16:46:19+08:00, 2009:12:18 17:47:07+08:00, 2010:02:05 15:48+08:00, 2010:08:20 08:39:57+08:00, 2010:08:20 12:32:03+08:00, 2010:10:21 16:40:01+08:00, 2010:11:06 14:40+08:00, 2010:11:08 09:13:48+08:00, 2010:11:09 11:24:26+08:00, 2011:01:13 11:20:28+08:00, 2011:01:14 09:32:45+08:00, 2012:12:08 13:29:51+08:00, 2012:12:21 08:57:37+08:00, 2012:12:29 16:12:58+08:00, 2013:05:09 08:28:08+08:00, 2013:05:09 08:30:02+08:00, 2013:05:09 08:44:24+08:00
History Software Agent          : Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5
History Changed                 : /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /
History Params                  : from application/vnd.adobe.illustrator to application/vnd.adobe.illustrator
Derived From Instance ID        : uuid:1e64ed95-ca85-423b-9266-53eb10896892
Derived From Document ID        : xmp.did:0D2DAF963FB8E211B953FD11DEEDFEF3
Derived From Original Document ID: uuid:9E3E5C9A8C81DB118734DB58FDDE4BA7
Derived From Rendition Class    : proof:pdf
Startup Profile                 : Basic RGB
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : True
Max Page Size W                 : 256.999817
Max Page Size H                 : 182.000088
Max Page Size Unit              : Millimeters
Font Name                       : Arial-BoldMT, Arial-Black, ArialMT, AdobeSongStd-Light, SimHei, TimesNewRomanPS-ItalicMT
Font Family                     : Arial, Arial, Arial, Adobe 宋体 Std, 黑体, Times New Roman
Font Face                       : Bold, Black, Regular, L, Regular, Italic
Font Type                       : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type
Font Version                    : Version 5.20, Version 5.06, Version 5.20, Version 5.002;PS 5.002;hotconv 1.0.49;makeotf.lib2.0.15106, Version 5.01, Version 5.20
Font Composite                  : False, False, False, False, False, False
Font File Name                  : arialbd.ttf, ariblk.ttf, arial.ttf, AdobeSongStd-Light.otf, simhei.ttf, timesi.ttf
Plate Names                     : Cyan, Magenta, Yellow, Black, PANTONE 286 CVU
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Group Name        : 初始屏幕
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: R=180 G=58 B=228
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Cyan    : 48.046899
Swatch Groups Colorants Magenta : 78.906298
Swatch Groups Colorants Yellow  : 0.000000
Swatch Groups Colorants Black   : 0.000000
Producer                        : Adobe PDF library 9.90
Keywords                        : GBF-1251-B
Page Count                      : 9
Author                          : Shuting
Subject                         : User Manual
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OU9LS108-B06

Navigation menu