Trilliant Networks SC2110 802.11 Based, Fixed Wireless Node User Manual installation Manual

Trilliant Networks, Inc. 802.11 Based, Fixed Wireless Node installation Manual

Contents

installation Manual

Download: Trilliant Networks SC2110 802.11 Based, Fixed Wireless Node User Manual installation Manual
Mirror Download [FCC.gov]Trilliant Networks SC2110 802.11 Based, Fixed Wireless Node User Manual installation Manual
Document ID697163
Application ID8tL9xKgfYs1IQ6WZfPI0mQ==
Document Descriptioninstallation Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize71.12kB (888952 bits)
Date Submitted2006-08-24 00:00:00
Date Available2006-08-24 00:00:00
Creation Date2006-05-17 14:41:04
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2006-08-24 11:34:51
Document Titleinstallation Manual
Document CreatorAdobe InDesign CS2 (4.0)

1 Attach stand
2 Power on
What‘s next?
Ethernet
cable
COMP
UTER
IM ARN
IN PRO ING:
C STAL PER
YOUOULD DALATION
R CO MA
MPU GE
TER
POWE
SkyConnector Indoor
Installation Guide
CPE
CPE
•
•
•
•
•
•
SkyConnector Indoor
Desk stand and mounting knobs
Power injector
AC adapter
Mounting hardware
Two Ethernet cables (25-foot
and 7-foot)
About the SkyConnector
C OM
PUTE
Contents of the kit
mounting knob
Network information
RJ-45 port
IM ARN
IN PRO ING
C STA PER :
YOUOULD DLLATION
R CO AM
MPU AGE
T ER
desk stand
CPE
AC adapter
POW
ER
Your SkyPilot™ SkyConnector™
Indoor kit provides everything you
need to set up your SkyConnector
and connect to a provider’s wireless
mesh network.
power injector
Remove the adhesive backing from the four foot pads and place them on the underside
of the desk stand.
Place the SkyConnector in the desk stand and insert the two knobs as shown. Tighten
the knobs to secure the device.
3 Locate signal
Review the documentation provided to you
by your service provider for instructions on
configuring your computer for access to the
Internet as well as broadband applications
and services.
ISP help desk
IP address
Plug one end of the 25-foot Ethernet cable into the RJ-45 port on the SkyConnector and
the other end into the port labeled “CPE” on the power injector.
Connect the AC adapter to the power injector, and plug the adapter into an AC outlet.
The Power LED lights to indicate the device is powered on.
Netmask
DNS (name servers)
4 Connect computer
computer
Your SkyConnector is a plug-andplay device that connects you to a
SkyPilot wireless network providing
wireless access to the Internet.
RJ-45 port
© 2006 SkyPilot Networks, Inc. All rights reserved. SkyConnector, SkyPilot,
SkyPilot Networks, the SkyPilot logo, and other designated trademarks, trade
names, logos, and brands are the property of SkyPilot Networks, Inc. or their
respective owners. Product specifications are subject to change without notice.
This material is provided for informational purposes only; SkyPilot assumes
no liability related to its use and expressly disclaims any implied warranties of
merchantability or fitness for any particular purpose.
For optimal operation, you need to
place the SkyConnector in a location that has a line of sight to other
SkyPilot equipment.
Blinking WAN Act LED indicates network signal.
Link
Act
LAN
PWR
Link
Act
WAN
Solid WAN Act LED indicates network connection.
Link
Act
LAN
PWR
Link
Act
WAN
Move the SkyConnector to different parts of the building to find the strongest SkyPilot
network signal. When the SkyConnector detects a signal, the WAN Act (WAN Activity)
LED starts to blink. (The faster the LED blinks, the stronger the signal.) If the WAN Act
LED does not start blinking within 30 seconds, try another location.
90 seconds after a signal is located, the WAN Link LED should start blinking, slowly then
more rapidly. When the WAN Link LED turn solid, you are connected to the network.
Solid LAN Link light indicates
successful connection with
computer.
Link
Act
LAN
PWR
Link
Act
WAN
Attach one end of the 7-foot Ethernet cable to the port labeled “Computer” on the power
injector and the other end into an Ethernet port on your personal computer or other
network device, such as a router.
When SkyConnector Indoor is properly connected to the computer, the LAN Link LED
lights to indicate a successful connection between the devices.
2055 Laurelwood Road
Santa Clara, CA 95054-2747
(408) 764-8000 or
(866) SKYPILOT
www.skypilot.com
FCC Regulatory Information
FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
The user of this product is cautioned that changes or modifications made to the
equipment without the approval of the manufacturer void the user's authority to
operate the equipment.
FCC Radiation Exposure Limits
To comply with FCC RF exposure requirements in section 1.1307, a minimum
paration distance of 40 cm (16 inches) is required between the antenna and all
persons.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2006:05:17 14:41:04-07:00
Creator                         : Adobe InDesign CS2 (4.0)
Modify Date                     : 2006:08:24 11:34:51-07:00
Tagged PDF                      : Yes
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Creation Date                   : 2006:05:17 14:41:04-07:00
Mod Date                        : 2006:08:24 11:34:51-07:00
Metadata Date                   : 2006:08:24 11:34:51-07:00
Creator Tool                    : Adobe InDesign CS2 (4.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 4787 bytes, use -b option to extract)
Instance ID                     : uuid:7d2c8b62-3dd1-4144-915e-ad0632704c94
Document ID                     : adobe:docid:indd:7eae3bd5-e612-11da-bf87-9051d2ced5ee
Rendition Class                 : proof:pdf
Derived From Instance ID        : 7eae3bd4-e612-11da-bf87-9051d2ced5ee
Derived From Document ID        : adobe:docid:indd:7eae3bd2-e612-11da-bf87-9051d2ced5ee
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:1c8b5d82-e4bc-11da-b124-001124df0f94, uuid:04b23e51-e4d1-11da-b124-001124df0f94, uuid:A25CE5F8E61311DA84C69678BAE98525
Manifest Reference Document ID  : uuid:A16E2594D59911DA956682215A25FF69, adobe:docid:photoshop:1bd27a78-e025-11da-9904-fdb777b99b41, uuid:A25CE5F9E61311DA84C69678BAE98525, uuid:A25CE5F7E61311DA84C69678BAE98525
Format                          : application/pdf
Page Count                      : 2
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RV7-SC2110

Navigation menu