Triple Plus NGLSM Wireless System for gas leakage detection and prevention User Manual

Triple Plus Wireless System for gas leakage detection and prevention

User Manual

Download: Triple Plus NGLSM Wireless System for gas leakage detection and prevention User Manual
Mirror Download [FCC.gov]Triple Plus NGLSM Wireless System for gas leakage detection and prevention User Manual
Document ID2793182
Application IDUX1y3YtLVQVsVXLR3pOoog==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize147.28kB (1840957 bits)
Date Submitted2015-10-26 00:00:00
Date Available2015-10-26 00:00:00
Creation Date2015-09-10 11:25:11
Producing SoftwareMac OS X 10.7.5 Quartz PDFContext
Document Lastmod2015-09-10 11:25:11
Document TitleUser Manual
Document CreatorPowerPoint
Document Author: Tali

NGLTM	
  Gas	
  Product	
  Installa3on	
  Instruc3ons	
NGL-INST-001E	
NGLTM	
  Gas	
  Product	
  Installa3on	
  Instruc3ons	
Compliance	
  with	
  regula3ons	
  
This	
  product	
  is	
  intended	
  exclusively	
  for	
  detec3on	
  of	
  liquefied	
  petroleum	
  gas	
  (LPG)	
  or	
  natural	
  gas	
  
(NG.)	
  	
  
It	
  should	
  not	
  be	
  used	
  for	
  detec3on	
  of	
  other	
  gases	
  or	
  fire.	
  	
  
Complies	
  with	
  standards	
  FCC	
  |	
  CE	
  	
  |	
  EN	
  50194	
  |	
  	
  EN	
  50270	
  |	
  EN	
  300	
  |	
  EN	
  301	
  |	
  ISO9001.	
System	
  descrip3on	
  
The	
  NGLTM	
  wireless	
  detec3on	
  and	
  preven3on	
  system	
  was	
  designed	
  to	
  detect	
  gas	
  leakage	
  and	
  
shut	
  down	
  the	
  gas	
  supply	
  by	
  way	
  of	
  wireless	
  communica3on.	
  Each	
  installa3on	
  may	
  include	
  
up	
  to	
  6	
  different	
  detectors	
  with	
  one	
  that	
  would	
  be	
  defined	
  during	
  the	
  detec3on	
  as	
  main	
  
detector	
  (MASTER)	
  and	
  one	
  Shut-­‐off	
  unit	
  to	
  be	
  installed	
  on	
  an	
  exis3ng	
  gas	
  valve.	
  	
Content	
  of	
  the	
  package	
  
1.
2.
3.
4.
5.
  Shut-­‐off unit.	
  	
  
Adapter	
  between	
  the	
  Shut-­‐off	
  unit	
  and	
  the	
  gas	
  valve.	
  
Gas	
  detector	
  
  CR123	
  baYery	
  Installa3on	
  Instruc3ons.	
Detector	
  descrip3on	
  
1. 	
  Green	
  lamp	
  means	
  that	
  the	
  detector	
  is	
  properly	
  ac3vated	
  and	
  
opera3ve	
  and	
  indicates	
  statuses	
  of	
  weak	
  baYery.	
  	
  
2. 	
  A	
  red	
  light	
  indicates	
  a	
  gas	
  leak	
  detec3on.	
  	
  
3. 	
  A	
  green	
  communica3on	
  light	
  indicates	
  the	
  existence	
  of	
  proper	
  communica3on	
  
between	
  the	
  detector	
  and	
  the	
  Shut-­‐off	
  unit.	
  	
  
4. 	
  Test	
  buYon.	
  
5. 	
  Audible	
  Alarm	
  
6. 	
  Mains	
  supply	
  
(Use	
  a	
  designated	
  AC/DC	
  adapter)	
  
Descrip3on	
  of	
  the	
  Shut-­‐off	
  unit	
  
1.
2.
3.
4.
5.
Main	
  gas	
  unit	
  
  Adapter	
  (to	
  be	
  installed	
  in	
  the	
  main	
  gas	
  unit.)	
  
  	
  Manual	
  opening/	
  closing	
  handle.	
  	
  
BuYon	
  for	
  manual	
  release	
  to	
  "Closed"	
  state.	
  
  BaYery	
  cover	
  (not	
  presented.)	
  
System	
  installa3on	
  
Installa3on	
  of	
  the	
  detector(s)	
  
The	
  loca3on	
  of	
  the	
  gas	
  detector	
  depends	
  of	
  the	
  type	
  of	
  gas	
  used.	
  BeYer	
  
communica3on	
  can	
  be	
  achieved	
  by	
  maintaining	
  a	
  direct	
  line	
  of	
  sight	
  between	
  the	
  
various	
  system	
  components.	
  Before	
  performing	
  the	
  installa3on,	
  please	
  note	
  the	
  
detector	
  loca3on	
  recommenda3ons:	
  
Natural	
  gas	
  is	
  lighter	
  than	
  air,	
  hence	
  the	
  detector	
  should	
  be	
  located	
  over	
  the	
  
topmost	
  window	
  or	
  door	
  aperture,	
  but	
  no	
  more	
  than	
  30	
  cm	
  beneath	
  the	
  ceiling	
  
level.	
  
Liquefied	
  petroleum	
  gas	
  (LPG)	
  is	
  heavier	
  than	
  air,	
  hence	
  the	
  detector	
  should	
  be	
  
located	
  below	
  the	
  level	
  where	
  a	
  poten3al	
  gas	
  leak	
  may	
  occur	
  and	
  no	
  more	
  than	
  30	
  
cm	
  above	
  floor	
  level.	
  	
  
The	
  NG	
  or	
  LPG	
  detector	
  should	
  be	
  located	
  1	
  to	
  4	
  meters	
  from	
  the	
  gas	
  device.	
Places	
  where	
  the	
  detector	
  should	
  NOT	
  be	
  posi3oned	
  
•In	
  a	
  closet	
  or	
  in	
  any	
  closed	
  compound.	
  	
  
•Where	
  unit	
  ven3la3on	
  may	
  be	
  obstructed	
  by	
  curtains	
  or	
  furniture.	
  	
  
•Where	
  dirt	
  and	
  dust	
  may	
  accumulate	
  and	
  block	
  the	
  sensor,	
  preven3ng	
  its	
  opera3on.	
  	
  
•Where	
  there	
  is	
  humidity	
  and	
  moisture.	
  	
  
•Directly	
  over	
  cooking	
  installa3ons.	
  	
  
•Directly	
  over	
  sinks.	
  	
  
•By	
  a	
  door,	
  window	
  or	
  any	
  other	
  place	
  that	
  may	
  be	
  subject	
  to	
  drads	
  such	
  as	
  an	
  air	
  
extrac3on	
  fan	
  or	
  ven3la3on	
  aperture.	
  	
  
•Anywhere	
  out	
  of	
  a	
  structure.	
  	
  
•Where	
  temperatures	
  may	
  drop	
  below	
  zero	
  degrees	
  cen3grade	
  or	
  exceed	
  55	
  degrees	
  
cen3grade.	
  	
  
•Where	
  it	
  may	
  be	
  subject	
  to	
  impact	
  or	
  damage.	
  	
  
•When	
  the	
  sensor	
  is	
  installed	
  in	
  an	
  area	
  with	
  rough	
  working	
  condi3ons	
  such	
  as	
  extra	
  
wet	
  kitchens	
  and	
  laundry	
  rooms,	
  it	
  should	
  be	
  protected	
  by	
  a	
  transparent	
  plas3c	
  case	
  
with	
  holes	
  at	
  its	
  boYom.	
Detector	
  installa3on	
  stages	
  
1.
Locate	
  a	
  power	
  outlet	
  complying	
  with	
  the	
  requirements	
  of	
  sefng	
  up	
  a	
  detector.	
  Make	
  
sure	
  that	
  the	
  electric	
  cable	
  of	
  the	
  adapter	
  can	
  be	
  freely	
  aYached	
  in	
  the	
  loca3on	
  desired	
  for	
  
the	
  detector.	
  	
  
2. Take	
  the	
  electric	
  adapter	
  and	
  detector	
  out	
  of	
  the	
  box.	
3. Remove	
  the	
  detector	
  mount.	
  	
  
4. Posi3on	
  the	
  mount	
  on	
  the	
  wall.	
  
5. Mark	
  the	
  mount's	
  two	
  holes	
  on	
  the	
  wall.	
  
6. Drill	
  two	
  holes,	
  using	
  a	
  wood	
  or	
  concrete	
  drill	
  or	
  used	
  drywall	
  studs.	
  
7. AYach	
  the	
  detector's	
  mount	
  to	
  the	
  wall	
  using	
  2	
  x	
  5	
  mm	
  screws.	
8. AYach	
  the	
  detector	
  onto	
  the	
  mount	
  and	
  turn	
  it	
  slightly	
  to	
  the	
  right	
  un3l	
  it	
  is	
  locked	
  into	
  its	
  
place.	
  	
  
9. This	
  is	
  how	
  the	
  result	
  should	
  be.	
  
10. Connect	
  the	
  detector	
  to	
  the	
  power	
  outlet	
  and	
  ensure	
  that	
  all	
  3	
  LED	
  lights	
  turn	
  on	
  and	
  a	
  
clear	
  beep	
  sound	
  is	
  heard.	
  
11. For	
  the	
  3me	
  being,	
  un3l	
  the	
  Shut-­‐off	
  unit	
  is	
  installed,	
  disconnect	
  the	
  power.	
  	
10	
Shut-­‐off	
  unit	
  installa3on	
  
The	
  efficiency	
  of	
  the	
  system	
  relies	
  of	
  the	
  quality	
  of	
  communica3on.	
  	
  BeYer	
  
communica3on	
  can	
  be	
  achieved	
  by	
  maintaining	
  a	
  direct	
  line	
  of	
  sight	
  between	
  the	
  
components.	
  The	
  Shut-­‐off	
  unit	
  should	
  not	
  be	
  installed	
  in	
  closed	
  metal	
  cases,	
  as	
  it	
  may	
  
reduce	
  the	
  effec3ve	
  range	
  of	
  communica3on.	
  	
  
Shut-­‐off	
  unit	
  installa3on	
  stages	
Dismantling	
  of	
  the	
  original	
  valve	
  unit	
Connec3on	
  of	
  the	
  valve	
  to	
  the	
  base	
  unit	
Installa3on	
  of	
  the	
  1/2"	
  -­‐	
  3/8"	
  
adapter	
ASaching	
  the	
  base	
  unit	
  to	
  a	
  wall	
Installa3on	
  of	
  the	
  valve	
  front	
  unit	
  and	
  performing	
  
  manual	
  test	
Inser3ng	
  the	
  baSery	
  and	
  the	
  LED	
  indicator	
System's	
  component	
  synchroniza3on	
  and	
  ac3va3on	
  
Synchroniza3on	
  of	
  the	
  Shut-­‐off unit	
  with	
  the	
  network	
  and	
  the	
  connected	
  detectors	
  
is	
  essen3al	
  to	
  proper	
  opera3on	
  of	
  the	
  system	
  and	
  prevents	
  random	
  opera3on	
  by	
  
adjacent	
  systems.	
  Read	
  carefully	
  the	
  instruc3ons	
  and	
  follow	
  them	
  precisely:	
  
Coordina3on	
  of	
  the	
  communica3on	
  ID	
  No.	
  of	
  the	
  Shut-­‐off unit	
  with	
  the	
  detectors	
  is	
  
part	
  of	
  this	
  process.	
  A	
  10-­‐minute	
  set	
  3me	
  is	
  defined	
  within	
  the	
  system	
  to	
  enable	
  
comple3on	
  of	
  the	
  synchroniza3on	
  process.	
  	
  
The	
  first	
  detector	
  to	
  be	
  installed	
  is	
  the	
  main	
  detector	
  (MASTER).	
  We	
  recommend	
  
posi3oning	
  the	
  master	
  detector	
  closest	
  to	
  the	
  Shut-­‐off	
  unit	
  and	
  the	
  most	
  visual	
  
rela3ve	
  to	
  it.	
  The	
  process	
  will	
  commence	
  upon	
  installa3on	
  of	
  the	
  baYery	
  within	
  the	
  
Shut-­‐off	
  unit.	
  
Opera3on/	
  indica3on	
  
OPERATION 	
  
  
  
  
  
  
  
Inser3on	
  of	
  a	
  baYery	
  into	
  the	
  Shut-­‐off	
  unit 	
  
Connec3on	
  of	
  the	
  main	
  detector	
  (MASTER) 	
  
Detec3on	
  of	
  the	
  main	
  detector	
  (SLAVE) 	
  
Connec3on	
  of	
  the	
  remaining	
  detectors	
  (SLAVE) 	
  
Synchroniza3on	
  of	
  the	
  system	
  (Ac3ve)	
  -­‐	
  ader	
  the	
  last	
  detector	
  is	
  
connected,	
  press	
  the	
  TEST	
  buYon	
  of	
  one	
  of	
  the	
  detectors. 	
  
System	
  self-­‐synchroniza3on. 	
  
Indica3on 	
  
•
Ac3va3on	
  of	
  a	
  green	
  LED	
  light.	
  
•
The	
  engine	
  rotates	
  by	
  180	
  degrees.	
  
•
Three	
  LED	
  lights	
  light	
  up	
  for	
  2	
  seconds.	
  
•
  beep	
  sound	
  is	
  heard.	
  
•
Only	
  the	
  Power	
  LED	
  is	
  led	
  ac3ve.	
  
•
All	
  LED	
  lights	
  blink	
  once.	
  
•
The	
  Power	
  and	
  COM	
  lights	
  remain	
  ac3ve. 	
  
•
The	
  LED	
  light	
  of	
  each	
  detector	
  will	
  blink	
  according	
  to	
  its	
  posi3on	
  in	
  the	
  installa3on	
  
sequence.	
  
•
The	
  Power	
  and	
  COM	
  lights	
  remain	
  ac3ve	
  in	
  each	
  iden3fied	
  detector. 	
  
•
Long	
  beep. 	
  
•
All	
  the	
  lights	
  are	
  on	
  for	
  a	
  second.	
  
•
The	
  Power	
  and	
  COM	
  lights	
  remain	
  ac3ve	
  in	
  each	
  detector. 	
  
Ader	
  10	
  minutes,	
  the	
  system	
  synchronizes	
  itself	
  independently	
  even	
  if	
  the	
  installer	
  did	
  not	
  
perform	
  any	
  synchroniza3on	
  ac3on	
  for	
  a	
  while. 	
  
Synchroniza3on	
  reset	
  (Reset	
  HEAD)	
If	
  the	
  synchroniza3on	
  process	
  fails	
  in	
  seYng	
  the	
  configura3on	
  of	
  all	
  the	
  detectors	
  
•
Disconnect	
  the	
  unit	
  from	
  the	
  main	
  power	
  supply,	
  wait	
  approximately	
  30	
  seconds	
  
and	
  reconnect	
  the	
  unit.	
  
•
Press	
  the	
  TEST	
  buYon	
  in	
  each	
  detector	
  for	
  15	
  seconds.	
  
•
Disconnect	
  the	
  unit	
  from	
  the	
  main	
  power	
  supply,	
  wait	
  approximately	
  30	
  seconds	
  
and	
  reconnect	
  the	
  unit.	
  
•
Remove	
  the	
  baYery	
  from	
  the	
  Shut-­‐off	
  unit.	
  
•
Wait	
  30	
  seconds.	
  
•
Reinstall	
  the	
  baYery	
  in	
  the	
  Shut-­‐off	
  unit.	
  
•
Restart	
  the	
  synchroniza3on	
  process.	
  
Federal	
  Communica3ons	
  Commission	
  (FCC)	
  Statement	
  
Radio	
  Frequency	
  Interference	
  (RFI)	
  (FCC	
  15.105)	
  
This	
  equipment	
  has	
  been	
  tested	
  and	
  found	
  to	
  comply	
  with	
  the	
  limits	
  for	
  Class	
  A	
  digital	
  devices	
  
pursuant	
  to	
  Part	
  15	
  of	
  the	
  FCC	
  Rules.	
  These	
  limits	
  are	
  designed	
  to	
  provide	
  reasonable	
  protec3on	
  
against	
  harmful	
  interference	
  in	
  a	
  residen3al	
  environment.	
  This	
  equipment	
  generates,	
  uses,	
  	
  
and	
  can	
  radiate	
  radio	
  frequency	
  energy,	
  and	
  if	
  not	
  installed	
  and	
  used	
  in	
  accordance	
  with	
  the	
  
instruc3on	
  manual,	
  may	
  cause	
  harmful	
  interference	
  to	
  radio	
  communica3ons.	
  	
  
However,	
  there	
  is	
  no	
  guarantee	
  that	
  interference	
  will	
  not	
  occur	
  in	
  a	
  par3cular	
  installa3on.	
  	
  
If	
  this	
  equipment	
  does	
  cause	
  harmful	
  interference	
  to	
  radio	
  or	
  television	
  recep3on,	
  which	
  can	
  be	
  
determined	
  by	
  turning	
  the	
  equipment	
  off	
  and	
  on,	
  the	
  user	
  is	
  encouraged	
  to	
  try	
  and	
  correct	
  the	
  
interference	
  by	
  one	
  or	
  more	
  of	
  the	
  following	
  measures:	
  
  
• Reorient	
  or	
  relocate	
  the	
  receiving	
  antenna.	
  
• Increase	
  the	
  separa3on	
  between	
  the	
  equipment	
  and	
  the	
  receiver.	
  
• Connect	
  the	
  equipment	
  into	
  an	
  outlet	
  on	
  a	
  circuit	
  different	
  from	
  that	
  to	
  which	
  
the	
  receiver	
  is	
  connected.	
  
• Consult	
  the	
  dealer	
  or	
  an	
  experienced	
  radio/	
  TV	
  technician	
  for	
  help.	
  
Federal	
  Communica3ons	
  Commission	
  (FCC)	
  Statement	
  
Labeling	
  Requirements	
  (FCC	
  15.19)	
  
This	
  device	
  complies	
  with	
  Part	
  15	
  of	
  FCC	
  rules.	
  Opera3on	
  is	
  subject	
  to	
  the	
  following	
  two	
  
condi3ons:	
  (1)	
  this	
  device	
  may	
  not	
  cause	
  harmful	
  interference,	
  and	
  (2)	
  this	
  device	
  must	
  accept	
  
any	
  interference	
  received,	
  including	
  interference	
  that	
  may	
  cause	
  undesired	
  opera3on.	
  
  
Modifica3ons	
  (FCC	
  15.21)	
  
Changes	
  or	
  modifica3ons	
  to	
  this	
  equipment	
  not	
  expressly	
  approved	
  by	
  Triple	
  Plus	
  LTD	
  may	
  void	
  
the	
  user’s	
  authority	
  to	
  operate	
  this	
  equipment.	
  
  
  RF	
  Exposure	
  info	
  (FCC	
  2.1093)	
  
This	
  equipment	
  has	
  been	
  approved	
  for	
  mobile	
  applica3ons	
  where	
  the	
  equipment	
  should	
  be	
  used	
  
at	
  distances	
  greater	
  than	
  20cm	
  from	
  the	
  human	
  body	
  (with	
  the	
  Excep3on	
  of	
  hands,	
  wrists,	
  feet	
  
and	
  ankles).	
  Opera3on	
  at	
  distances	
  less	
  than	
  20	
  cm	
  is	
  strictly	
  prohibited.	
  

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : No
Page Count                      : 16
PDF Version                     : 1.4
Author                          : Tali
Producer                        : Mac OS X 10.7.5 Quartz PDFContext
Creator                         : PowerPoint
Create Date                     : 2015:09:10 11:25:11Z
Modify Date                     : 2015:09:10 11:25:11Z
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AFOINGLSM

Navigation menu