Tyco Safety Canada 00LINKS2450 LINKS 2450 Long Range RF Transmitter User Manual Installation manual
Digital Security Controls Ltd. LINKS 2450 Long Range RF Transmitter Installation manual
Installation manual
•WARNING• Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. How to Contact Us: Sales For information about additional products, please call our sales number: 1-888-623-7873, fax us at 1-416-665-4222 or e-mail us at sales@sur-gard.com. Technical Support If you have questions or problems when using Sur-Gard products, you can call technical support. If you are within the United States, Puerto Rico, the U.S. Virgin Islands or Canada, you can get support by dialing 1-888-623-7873 ext.1. If you are outside these areas, please call (416) 665-0051 ext.1, or e-mail us at support@sur-gard.com. Long Range RF Transmitter Internet Visit our Sur-Gard WWW site. You can search the Sur-Gard technical information database and read about our new productsas well as send us your questions on-line. Our World Wide Web address is http://www.sur-gard.com. © 2000 SG Wireless Communications 401 Magnetic Drive, Units #24-28 Downsview, Ontario, Canada M3J 3H9 29003619 R001 INSTALLATION MANUAL Version 1.2 Limited Warranty SG Wireless Communications warrants that for a period of twelve months from the date of purchase, the product shall be free from defects in materials and workmanship under normal use and that in fulfillment of any breech of such warranty, SG Wireless Communications shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of SG Wireless Communications, such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or improper application of the equipment. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of SG Wireless Communications. SG Wireless Communications neither assumes, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. In no event shall SG Wireless Communications be liable for any direct or indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product. WARNING: SG Wireless Communications recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected. TABLE OF CONTENTS Section 1: Introduction 1.1 Specifications ........................................................................................ 1 1.2 Antenna ................................................................................................. 2 Section 2: Installing the Links2450 2.1 Unpacking the LINKS2450 .................................................................... 3 2.2 Select a Mounting Location .................................................................. 3 2.3 Connect a Power Supply ....................................................................... 3 2.4 Mount and Wire the LINKS2450 ........................................................... 4 Diagram 2-1: Hook-up For PC5010, PC5015, PC1555/1565, PC1575/1580 or PC580/585 Panels .................................................... 5 Diagram 2-2: Hook-up for PC4010/4020 v3.0 Panels ........................... 6 Section 3: Programming the LINKS2450 3.1 Programming a LINKS2450 Connected to a PC5015, PC5010, PC1575/1580, PC1555/1565 PC580/585 Panel ................................... 7 3.2 Programming a LINKS2450 for Use with a PC4010/PC4020 v3.0 or higher panel. ................................................ 8 Diagram 3-1: Connecting the LINKS2450 to a PC2550RK Keypad ........ 8 Section 4: Programming Descriptions 10 [01] Module Configuration ......................................................................... 10 [10] LINKS 2450 Account Code ................................................................. 10 [20] Maintenance Alarms and Restoral Reporting Codes ......................... 10 [30] Call Direction Options (PC5015, PC5010, PC1575/1580, PC1555/1565 and PC580/585 panels only) ...................................... 10 [81] Miscellaneous Alarm Reporting Codes (PC1575/1580 panel only) ..... 11 [82] Miscellaneous Restoral Reporting Codes (PC1575/1580 panel only) .... 11 [83] Miscellaneous Alarm Reporting Codes (PC1555/1565 v2.0 panel only) .......................................................... 11 Section 5: Testing the LINKS2450 12 5.1 Performing a LINKS Test Transmission .............................................. 12 5.2 “On Air” Indication ............................................................................... 12 5.3 Troubleshooting ................................................................................... 12 5.4 Testing Tools ........................................................................................ 12 5.5 Periodic Test Transmission .................................................................. 12 Section 6: Reset LINKS2450 Programming to Factory Default 13 6.1 Reset the LINKS2450 on a PC1575/1580 Panel ................................ 13 6.2 Reset the LINKS2450 on a PC5015 v2.2, PC5010 v2.0, PC1555/1565 or PC580/585 Panel .................................................... 13 6.3 Perform a Hardware Reset (All panels) ............................................. 13 Programming Worksheets 14 NOTES: ii NOTES: NOTES: INTRODUCTION Section 1 The LINKS2450 transmits alarm system information over a long-range radio network. It may be used with the following DSC alarm control panels: • PC1575/1580 v1.0 • PC4010/4020 v3.x • PC1555/1565 v2.x and up • PC5015 v2.2 • PC580/585 v2.x • PC5010 v1.0 and up This manual will describe how to install and program the LINKS2450 for connection to the above panels. 1.1 Specifications NOTE: If the panel uses automatic SIA or Contact ID communications formats, the reporting codes the LINKS2450 will send must still be programmed on the panel. • Power supply: 11.5-14VDC at 750mA (PS1520, PC5204, PC4204, or powered from Bell+/Aux- control panel terminals) • Radio transmitter frequency: range from 440 to 470MHz • Communication Buffer: 80 Events • Transmission Range: Approximately 16 Kilometers (10 Miles) • Cabinet dimensions: 4.17” high × 5.75” wide × 1” deep (104mm × 146mm × 26mm); color: white • Module supervision via the alarm control panel • Protected against static and lightning induced transients • Programming by keypad or downloading software. The LINKS2450 is complete with a default program and is operational with a minimum of programming. • To program via a keypad when connected to PC5015, PC5010, PC1575/1580, PC1555/1565 or PC580/585 panels, program the LINKS2450 using any system keypad • To program via a keypad when connected to PC4010/4020 v3.0 panels, program the LINKS2450 using a PC2550RK keypad connected directly to the LINKS2450. • EEPROM Memory The LINKS2450 uses EEPROM memory, which will retain all program information even if AC and battery power, are removed. 1.2 Antenna NOTE: You must match the antennas to the frequency you will be using. The antenna for the LINKS2450 is not supplied. For optimum performance of the LINKS2450, use a quality antenna system, such as model SLA-532, available from Safe Link Corporation. This 5/8 over 5/8 wave high performance antenna offers features specifically designed for security radio installations. • 5db gain two-piece mast with center coil • Standard frequency range 440-470MHz • Ten feet of coax with BNC connector attached. To ensure proper operation, mount the antenna at least ten feet from the LINKS 2450 unit. (See diagram below). [83] Miscellaneous Alarm Reporting Codes (PC1555/1565 v2.0 panel only) Default = FF I_______I_______I Police Code I_______I_______I Delinquency Code [96][Installer Code][96] Restore LINKS2450 Factory Default Programming for PC1575/ 1580 [993][Installer Code][993] Restore LINKS2450 Factory Default Programming for PC5015 v2.2, PC5010 v2.0, PC1555/1565 and PC580/585 PC4010/4020 LINKS2450 Toggle Options Program these options at a PC4010/4020 system keypad. See section 3.2 for more information. Ref # [000405] LINKS 2XXX (use arrow keys (< >) to scroll to each option) Option Default LINKS 2XXX N (Y for CF panels) Alarm/Restore N (Y for CF panels) Open/Close N (Y for CF panels) All Others N (Y for CF panels) 15 PROGRAMMING WORKSHEETS INSTALLING THE LINKS2450 [01] Module Configuration Before installing the LINKS2450, install and test the security system to which it will be connected, according to the system’s Installation Manual. Default ON I_______I Option ON Communications enabled OFF Communications disabled OFF I_______I Serial connection Keybus connection [10] LINKS2450 Account Code Default FF FF I_______I_______I Valid entries are 00-FF Enter two 2-digit hexadecimal numbers. I_______I_______I Keybus/Serial Fault Alarm I_______I_______I Keybus/Serial Fault Restoral I_______I_______I For future use OFF OFF I_______I I_______I I_______I I_______I I_______I I_______I 6-7 • LINKS2450 circuit board • LINKS2450 plastic cabinet CAUTION: Due to the sensitivity of the RF circuitry, avoid any contact with the coils and potentiometers on the LINKS2450 circuit board. The area where you mount the LINKS2450 should be: • dry • close to the installed alarm control panel cabinet. • far from sources of interference, including: electrical noise such as computers, televisions and electric motors in appliances and heating and air conditioning units; large metal objects like heating ducts and plumbing which may shield the antenna. If you must mount the LINKS2450 near such items, you may have to mount the antenna on a remote bracket away from the LINKS2450. • close to the power supply. See section 2.3 “Connect a Power Supply”. [30] Call Direction Options (PC5015, PC5010, PC1575/1580 and PC1555/1565 panels only) Option Check that each of these parts is included in your LINKS2450 package. 2.2 Select a Mounting Location Default = FF I_______I 2.1 Unpacking the LINKS2450 l_______I_______I [20] Maintenance Alarms and Restoral Reporting Codes Default ON ON OFF ON ON Section 2 ON Alarm/restore reporting enabled Tamper/restore reporting enabled Opening/closing reporting enabled System maintenance reporting enabled System test transmission reporting enabled For future use Future event Support OFF Disabled Disabled Disabled Disabled Disabled Enabled Disabled [81] Miscellaneous Alarm Reporting Codes (PC1575/1580 panel only) 2.3 Connect a Power Supply You can use the Bell+ and Aux- terminals from the control panel to power the LINKS2450. If you will be using a separate power supply, install it near the LINKS2450. Refer to the power supply’s installation instructions, for more information. NOTE: The current drawn by the LINKS2450 and the siren(s) connected to the Bell terminals must not exceed that specified by the rating of the control panel. Refer to your control panel’s Intallation Manual for more information. The wiring between the LINKS2450 and the power supply should not be longer than indicated in the table below: Wire Gauge (AWG) Maximum Wire Length (feet / meters) Default = FF I_______I_______I General Zone Fault Alarm I_______I_______I General System Tamper Alarm I_______I_______I General System Supervisory Alarm [82] Miscellaneous Restoral Reporting Codes (PC1575/1580 panel only) 22 15' / 4.5m 20 25' / 7.5m 18 40' / 12.0m You can double the maximum wire length if you double the conductors and connect them in parallel. Mount the LINKS2450 as close to the power supply as possible. Default = FF 14 I_______I_______I General Zone Fault Restore I_______I_______I General System Tamper Restore I_______I_______I General System Supervisory Restore 2.4 Mount and Wire the LINKS2450 1. Run the panel wiring and the power supply wiring to the LINKS2450 mounting location. 2. Remove the four screws that attach the LINKS2450 circuit board to the plastic cabinet. 3. Pull all wires through the hole at the back of the cabinet. 4. Mount the cabinet securely to the wall. Use the appropriate wall anchors when securing the panel to drywall, plaster, concrete, brick or similar surfaces. 5. Reattach the LINKS2450 into the mounted cabinet using the four mounting screws. 6. Find the antenna connection in the hole at the top of the cabinet. Secure the antenna to the LINKS2450 antenna connector. NOTE: Make sure an antenna is always connected to the LINKS2450 whenever it is operated. The unit will not work and may be damaged if an antenna is not installed. 7. Complete all wiring: If you will be connecting the LINKS2450 to a PC5015, PC5010, PC1575/1580, PC1555/1565 or PC580/585 panel, go to step 8a. If you will be connecting the LINKS2450 to a PC4010 or PC4020 panel, go to step 8b. 8a. Connect the LINKS2450 according to diagram 2-2. Make sure jumper J3 on the LINKS2450 is NOT shorted. 8b. Connect the LINKS2450 to a PC2550RK keypad according to diagram 31. Make sure jumper J3 on the LINKS2450 IS SHORTED. When you have finished programming, disconnect the power supply and the PC2550RK keypad from the LINKS2450. Remove the short from jumper J3. Connect the LINKS2450 to the control panel according to diagram 2-3. NOTE: Double-check all wiring to ensure that it is correct. Incorrect wiring connections may cause the LINKS2450 to operate improperly, or may damage the unit. RESET LINKS2450 PROGRAMMING TO FACTORY DEFAULT Section 6 If you need to reset the LINKS2450 to factory default programming, follow the directions in the appropriate sections below. 6.1 Reset the LINKS2450 on a PC1575/1580 Panel To reset the LINKS2450 on a PC1575/1580 panel, enter [96] [Installer’s Code] [96]. 6.2 Reset the LINKS2450 on a PC5015 v2.2, PC5010 v2.0, PC1555/ 1565 or PC580/585 Panel To reset the LINKS2450 on a PC5015 v2.2, PC5010 v2.0 or PC1555/1565 panel, enter [993] [Installer’s Code] [993]. NOTE: This command is unavailable on PC5010 v1.0. If v1.0 is used, you must perform a hardware reset (see section 6.3 below). 6.3 Perform a Hardware Reset (All panels) To reset the LINKS2450 when connected to a PC5010 v1.0 or a PC4010/4020 panel, you must perform a hardware reset. To do this: 1. Remove all power from the LINKS2450 2. Short j umper J3 3. Remove all wires from the YEL and GRN terminals 4. With a piece of wire, short the YEL terminal to the GRN terminal 5. Apply power to the LINKS2450 for 5 seconds. 6. Remove power from the LINKS2450 7. Reconnect all original wiring and re-power the LINKS2450 NOTE: If the LINKS2450 is connected to a PC4010/4020 panel, the programming done in the panel software will not be reset. See section 3.2, step 5 for information on re-programming the PC4010/4020 sections. 8. Connect the power: Connect the power terminals (VTX+ and VTX–) to a 11.5 14VDC, 1A power supply. CAUTION: Do not connect the power supply until all other wiring, including the antenna connection, has been completed and checked to ensure that it is correct. 13 TESTING THE LINKS2450 Section 5 Before testing the LINKS2450, ensure that the control panel is correctly programmed and operating properly. Refer to your system Installation Manual for instructions on testing your system. The control panel must be programmed properly in order for the LINKS2450 to operate. DIAGRAM 2-1 Hook-up For PC5010, PC5015, PC1555/1565, PC1575/1580 or PC580/585 Panels NOTE: Programming section [01], option 2 must be OFF for LINKS2450 to work with these panels. To check that the LINKS2450 is working, apply power to the unit after all wiring connections have been made. When the LINKS2450 is sending a transmission, the LED on the circuit board will turn on. 5.1 Performing a LINKS Test Transmission Contact the monitoring station to request a transmission test. Remove the telephone cord from the RJ31-X jack. Perform a Bell Test as described in the control panel’s Installation Manual. When the test is complete, contact the monitoring station to confirm the transmission. Perform additional test transmissions as required by the central station. 5.2 “On Air” Indication Whenever the LINKS unit is communicating, the LED on the unit’s circuit board will turn ON for each round of communications. Each event has 3 rounds. Therefore, if one reporting code is sent, the LED will activate 3 times to indicate each round. 5.3 Troubleshooting If the LINKS2450 is not working properly, check that all wiring and all programming is correct before calling for technical support. 5.4 Testing Tools The following tools are available from Safe Link: UHF RF Power Meter - Connects to the antenna jack on the LINKS2450. Indicates the transmit power of the radio. UHF Scanner - Checks that the radio is transmitting data. Frequency Counter - Checks that the LINKS2450 is transmitting on the correct frequency. 5.5 Periodic Test Transmission The LINKS 2450 will transmit a periodic test transmission at the time/day/interval using the Reporting code programmed in the main control panel. CAUTION: Due to the sensitivity of the RF circuitry, avoid any contact with the coils and potentiometers on the LINKS2450 circuit board. *If power supply supervision is required for the LINKS2450 VTX terminals, use the PC5204. If no supervision is needed, you can use the PS1520 or the control panel Bell+/Aux- terminals. 12 DIAGRAM 2-2 Hook-up for PC4010/4020 v3.0 Panels NOTE: Programming section [01], option 2 must be ON for LINKS2450 to work with these panels. [81] Miscellaneous Alarm Reporting Codes (PC1575/1580 panel only) Program 2 digit reporting codes for the following: • General Zone Fault Alarm This code will be sent when the LINKS2450 receives a General Zone Fault Alarm event from the PC1575/1580. • General System Tamper Alarm This code will be sent when the LINKS2450 receives a General System Tamper Alarm event from the PC1575/1580. • General System Supervisory Alarm This code will be sent when the LINKS2450 receives a General System Supervisory Alarm event from the PC1575/1580. [82] Miscellaneous Restoral Reporting Codes (PC1575/1580 panel only) Program 2 digit reporting codes for the following (see your PC1575/1580 Installation Manual for more information): • General Zone Fault Restoral: This code will be sent when the LINKS2450 receives a General Zone Fault Restoral event from the PC1575/1580. • General System Tamper Restoral: This code will be sent when the LINKS2450 receives a General System Tamper Restoral event from the PC1575/1580. • General System Supervisory Restoral: This code will be sent when the LINKS2450 receives a General System Supervisory Restoral event from the PC1575/1580. NOTE: Sections [81] and [82] apply to the PC1575/1580 only. All other panels will use the reporting codes that are programmed for these events in the panel. [83] Miscellaneous Alarm Reporting Codes (PC1555/1565 v2.0 panel only) Program 2 digit reporting codes for the following (see your PC1555/1565 Installation Manual for more information): • Police Code: This code will be sent when the LINKS2450 receives a Police Code event from the PC1555/1565. • Delinquency Code: This code will be sent when the LINKS2450 receives a Delinquency event from the PC1555/1565. CAUTION: Due to the sensitivity of the RF circuitry, avoid any contact with the coils and potentiometers on the LINKS2450 circuit board. *If power supply supervision is required for the LINKS2450 VTX terminals, use the PC4204. If no supervision is needed, you can use the PS1520 or the control panel Bell+/Aux- terminals . 11 PROGRAMMING DESCRIPTIONS Section 4 [01] Module Configuration Option 1: Communications Enabled / Disabled Enable this option to have the LINKS2450 initiate communications for all events that have reporting codes and call direction options (section [30]) programmed. Disable this option to test the system. Option 2: Serial Connection / Keybus Connection Enable this option if you will use the LINKS2450 with a PC4010/4020 panel. Disable this option if you will use the LINKS2450 with a PC5015, PC5010, PC1575/1580, PC1555/1565/1565 or PC580/585 panel. [10] LINKS2450 Account Code This 4-digit code is used to identify the system and is transmitted when the LINKS2450 initiates communications. Program a 4-digit code in this section using 2 two-digit Hexadecimal numbers. Refer to your control panel Installation Manual for instructions on programming hexadecimal digits. NOTE: An account number must be entered in this section before the LINKS2450 can send any communications. Programming [FFFF] will disable the LINKS2450. [20] Maintenance Alarms and Restoral Reporting Codes Program 2 digit reporting codes for the following: • Keybus/Serial Fault Alarm: This code will be sent when connection is lost to the panel for more than 30seconds. • Keybus/Serial Fault Restoral: This code will be sent when connection is restored to the panel for more than 30seconds. • For future use. [30] Call Direction Options (PC5015, PC5010, PC1575/1580, PC1555/ 1565 and PC580/585 panels only) Program which of the following reporting code types the LINKS2450 will send to the central station: • Alarm/restore reporting • Tamper/restore reporting • Opening/closing reporting • System maintenance reporting • System test transmission reporting • Future event support In most installations, you should program the tranmission of alarm/restore reporting codes only. Your radio network has limited bandwidth and capacity. The more signals each LINKS2450 transmits, the fewer LINKS2450s you will be able to install on your network. The Future Event Support option refers to reporting codes (events) that may be added to future software versions of DSC control panels. If you turn on the Future Event Support option, when the new events occur, the LINKS2450 will send reporting codes for the events to the central station. If you do not turn this option on, the LINKS2450 will not send reporting codes for events that are not currently included in one of the call direction groups. 10 PROGRAMMING THE LINKS2450 Section 3 See section 3.1 for programming instructions when connecting the LINKS2450 to a PC5015, PC5010, PC1575/1580, PC1555/1565 or PC580/585 panel. See section 3.2 for programming instructions when connecting the LINKS2450 to a PC4010 or PC4020 v3.0 panel. 3.1 Programming a LINKS2450 Connected to a PC5015, PC5010, PC1575/1580, PC1555/1565 or PC580/585 Panel. Program the LINKS2450 through Installer’s Programming at a system keypad. For instructions on using Installer’s Programming sections, please refer to Section 4 “How to Program” in your control panel Installation Manual. 1. Go to Installer’s Programming by entering [*][8][Installer’s code]. 2. For PC5015, PC5010, PC1555/1565 and PC580/585: Go to the LINKS2450 programming section by entering [803]. Program the following sections only (see section 4 for a description of each section). Record your programming choices in the worksheets at the end of this manual. [01] Module Configuration Option 1: Communications Enabled / Disabled Option 2: Serial Connection / Keybus Connection [10] LINKS2450 Account Code [20] Maintenance Alarms and Restoral Reporting Codes [30] Call Direction Options [83] Miscellaneous Alarm Reporting Codes (PC1555/1565 v2.0 panel only) 3. For PC1575/1580: Go to the LINKS2450 programming section by entering [86]. Program the following sections only. See section 4 for a description of each section. Record your programming choices in the worksheets at the end of this manual. [01] Module Configuration Option 1: Communications Enabled / Disabled Option 2: Serial Connection / Keybus Connection [10] LINKS2450 Account Code [20] Maintenance Alarms and Restoral Reporting Codes [30] Call Direction Options [81] Miscellaneous Alarm Reporting Codes (PC1575/1580 panel only) [82] Miscellaneous Restoral Reporting Codes (PC1575/1580 panel only) 4. To exit Installer’s Programming, press [#]. 3.2 Programming a LINKS2450 for Use with a PC4010/PC4020 v3.0 or higher panel. There are two stages in programming the LINKS2450 for a PC4010 or PC4020 panel: 1. Program the LINKS2450 programming sections from a PC2550RK keypad connected directly to the LINKS2450. 2. Program the LINKS2450 toggle options on the PC4010/4020 control panel. Program the LINKS2450 from a PC2550RK Keypad: 1. Make sure the LINKS2450 is connected to a PC2550RK keypad (refer to diagram 3-1). Make sure that jumper J3 is shorted. 2. Program the following sections only. Other programming sections are not relevant to PC4010/4020 panels. See section 4 for a detailed description of these sections. Enter the two-digit number for each section you want to program, then, enter the data required to complete the section programming. If you enter information into a section and make a mistake, press [#] to exit the section. Select the section again, and re-enter the information correctly. Record your programming choices in the worksheets at the end of this manual. [01] Module Configuration Option 1: Communications Enabled / Disabled. Press [1] to alternately enable or disable the option. Program the LINKS2450 Toggle Options on the Panel At a PC4010 or PC4020 system keypad, enter reference # [000405] and [*], or scroll to the “LINKS2XXX” programming section. (See the “How to Program” section in your PC4010/4020 Installation Manual for more information.) Use the arrow keys (< >) to scroll to each of the following toggle options. Press [*] to toggle the option ON or OFF. Record your programming choices in the worksheets at the end of this manual. LINKS 2XXX [20] Maintenance Alarms and Restoral Reporting Codes. Enter two hexadecimal digits for each code. 3. When you have finished programming the above sections, disconnect the power and the PC2550RK keypad. 4. Connect the LINKS2450 to the panel as in diagram 2-2. When enabled the PC4010 or PC4020 will send the events that are programmed to the LINKS 2450. The PC4010/ 4020 will only send the events that have reporting codes programmed and dialer directions enabled for them. No The PC4020 will not send events to the LINKS2450. Default condition is No. NOTE: The Communications Toggle option “Comms Enabled” must also be set to Yes for the PC4010/4020 to be able to send events to the LINKS 2XXX. To disable the PC4010/4020 telephone communications, but still allow the PC4010/ 4020 to communicate events through the LINKS 2XXX, set “Comms Enabled” to Yes, and the Dialer Directions to No for all 3 telephone numbers. Leaving all 3 telephone numbers unprogrammed will also disable telephone communications. See the “Communications Programming” section in your PC4010/4020 Installation Manual for more information. Alarm/Restore Yes Alarm and Restoral reporting codes are sent to the central station by the LINKS2450. No Alarm and Restoral reporting codes are not sent to the LINKS2450. Yes Opening and Closing reporting codes are sent to the central station by the LINKS2450. No Opening and Closing reporting codes are not sent to the LINKS2450 Yes All other reporting codes are sent to the central station by the LINKS2450. No All other reporting codes are not sent to the LINKS2450 Option 2: Serial Connection (Enabled) / Keybus Connection (Disabled). Press [2] to alternately enable or disable the option. [10] LINKS2450 Account Code. Enter 2 two-digit hexadecimal numbers. Refer to your Installation manual for information on Hexadecimal programming. Yes Default: No (Yes on PC4010CF/4020CF panels) Open/Close Default: No (Yes on PC4010CF/4020CF panels) All others Diagram 3-1 Connecting the LINKS2450 to a PC2550RK Keypad Default: No (Yes on PC4010CF/4020CF panels) To exit the LINKS2XXX programming section, press [#]. Program Panel Supervision for the LINKS2450 Panel supervision of the LINKS2450 is recommended when connected to PC4010/ 4020 panels. To have the panel supervise the LINKS2450, make sure the zone that the LINKS2450 is connected to on the panel is programmed for LINKS Supervisory (zone type [28]). When the zone is programmed this way, if the YEL terminal is not grounded (e.g. the wire is cut), the panel will generate a zone trouble and a LINKS trouble and will send the reporting code for the zone. See your PC4010/4020 Installation Manual for information on zone programming. FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient the receiving antenna • Relocate the alarm control with respect to the receiver • Move the alarm control away from the receiver • Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4. Notice to the user: It is the responsibility of the modem user to ensure that the modem / radio terminal combination has been aligned by qualified personnel before the equipment is used. Written proof, with the name of the technician and address of the service depot, should be available on request for inspection by representatives / radio inspectors of Industry Canada.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 2000:07:20 10:52:05 Producer : Acrobat Distiller 3.0 for Windows Modify Date : 2000:09:29 10:49:20-04:00 Page Count : 12EXIF Metadata provided by EXIF.tools