Tyco Safety Canada 02CL3050 Alarm System Wireless Communicator User Manual CL3050 eng im 2903453r001 QuickStart

Digital Security Controls Ltd. Alarm System Wireless Communicator CL3050 eng im 2903453r001 QuickStart

Users Manual

Standalone Wireless Communicator
Compatible with all PowerSeries keypads
Installation & Programming Guide
WARNING: This manual contains information on limitations
regarding product use and function and information on the limi-
tations as to liability of the manufacturer. Read the entire manual
carefully.
DRAF
T
Skyroute CL3050 Quick Start:
Note: Before you start, you must be enrolled with CONNECT 24
as an authorized installer to activate a Skyroute transceiver.
Enrollment is Free! If you are not already enrolled, call 1-888-
955-5583 in Canada or 1-888-251-7458 in the U.S. at least 24
hours before your first activation.
STEP 1 - SELECT BEST LOCATION (See Section 2.1)
Connect the Skyroute transceiver to a 7 Ah battery, as
described in Section 2.1. Determine the best location for
signal strength. If adequate signal strength cannot be
found, relocation may be required.
STEP 2 - CONNECT NECESSARY WIRING (See Section 6)
Mount the Skyroute, determine the desired mode of oper-
ation and connect the appropriate control panel, zone or
Keybus wiring as detailed in Section 6.
STEP 3 - PROGRAM (See Section 5)
If the default programming must be changed, connect a
PowerSeries keypad as shown in Section 5 and make the
desired changes.
STEP 4 - ACTIVATE (See Section 2.1)
Call the Connect 24 Voice Response Unit (VRU) at the toll
free number provided with your Dealer Confirmation.
STEP 5 - TEST (See Section 2.2)
Once activated, send two signals to your central station to
confirm proper operation.
YOUR SKYROUTE INSTALLATION IS NOW COMPLETE.
ALL OTHER PROGRAMMING SECTIONS IN THIS
MANUAL ARE OPTIONAL.
For Your Records
Location
Test Time & Day
Additional Notes
CONNECT 24TM Enrollment Information
Note: Only authorized dealers can enroll a wireless system to Connect 24.
Dealer application forms and additional information on the Connect 24 Voice
Response Unit can be found at the Connect 24 web site.
http://www.connect24.com/dealer.htm
The information required for activation is listed below. Ensure that all information
is available before calling the Connect 24 Voice Response Unit.
USA 1-888-251-7458 CAN 1-888-955-5583
Profile Number ...................................................5 digits I___I___I___I___I___I
The profile number provides Central Station Receiver information.
Installer ID Number............... 8-9 digits I___I___I___I___I___I___I___I___I___I
An Installer ID number was provided for each installer listed on the Dealer
Enrollment Form. This number can be found on the authorized Installer Card
sent with the Dealer Confirmation Form.
Installer PIN Number ................................................ 4 digits I___I___I___I___I
Each Installer provided a 4 digit PIN number on the Dealer Enrollment Form. If
you have forgotten your PIN Number contact Connect 24.
Central Station Account number ............ 2-6 digits I___I___I___I___I___I___I
This is the Account Number that will be sent to the Central Station.
NOTE: 4-digits maximum for Contact ID format.
Skyroute MIN....................10 digits I___I___I___I___I___I___I___I___I___I___I
The Skyroute Mobile Identification Number identifies the Skyroute transmitter.
The 10-digit MIN is located on the label affixed to your Skyroute Transmitter.
System ID Number (SID)................................5 digits I___I___I___I___I___I
The System ID Number informs Connect 24 and the cellular network the home
area that your transmitter is installed in. When this number is programmed into
an alarm panel it is entered in HEX format. When entering this number into
them Connect 24 Voice Response Unit, it is entered in Decimal Format.
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your
authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accor-
dance with the manufacturers instructions, may cause interference to radio and television reception. It has been type
tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart “B” of
Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residen-
tial installation. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause interference to television or radio reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•Re-orient the receiving antenna
•Relocate the alarm control with respect to the receiver
•Move the alarm control away from the receiver
•Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional sugges-
tions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/
Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washing-
ton, D.C. 20402, Stock # 004-000-00345-4.
Industry Canada COMPLIANCE STATEMENT
This Class B digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
Cet appareil numérique de la Classe B respecte toutes les exigences de règlement sur le matériel brouilleur du
Canada.
IC:160A - CL3050
The term "IC:" before the radio certification number only signifies that Industry Canada technical specifications
were met.
Limited Warranty
DSC warrants that for a period of one year from the date of purchase, the product shall be free of defects in material
and workmanship under normal use and that in fulfillment of any breach of such warranty, DSC shall, at its option,
repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only
to defects in materials and workmanship and not to damage incurred in shipping or handling, or damage due to
causes beyond the control of DSC, such as lightning, excessive voltage, mechanical shock, water damage or damage
arising out of abuse, alteration or improper application of the product.
The foregoing warranty shall apply only to the original purchaser, and shall be in lieu of any and all other warranties,
whether expressed or implied and of all other obligations or liabilities on the part of DSC. This warranty contains the
entire warranty. DSC neither assumes responsibility for, nor authorizes any other person purporting to act on its
behalf to modify or to change this warranty, nor assume for it any other warranty or liability concerning this product.
In no event shall DSC be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of
time or any other losses incurred by the purchaser in connection with the purchase, installation or operation or
failure of this product.
Important!
Test results are only valid at the time of testing. Results may vary with but are not limited to environmental
and structural changes. Electrical equipment operating in the immediate area may cause interference.
Skyroute, PowerSeries, Connect 24 are trademarks of DSC
WARNING: To satisfy FCC RF exposure requirements for mobile transmit-
ting devices, a separation distance of 30 cm or more must be maintained
between the antenna of this device and persons during device operation.
i
Table of Contents
Section 1: Introduction ...................................................................... 1
1.1 Specifications.......................................................................................................2
1.2 Unpacking ...........................................................................................................2
Section 2: Installation, Testing & Factory Defaults.......................... 3
2.1 Installation ...........................................................................................................3
2.2 Testing .................................................................................................................4
2.3 Resetting to Factory Defaults................................................................................4
Section 3: Controls & Indicators........................................................ 5
3.1 LED Indicators ......................................................................................................5
3.2 Enroll Button........................................................................................................6
3.3 Terminal Connections...........................................................................................6
Section 4: Power up Sequence.......................................................... 7
Section 5: System Programming....................................................... 8
Section 6: Programming Descriptions .............................................. 9
[01] Zone 1-2 Definitions ............................................................................................9
[02] Zone 3-8 Definitions ............................................................................................9
[03] Zone 1-2 Loop Response......................................................................................9
[10] Skyroute CL3050 Mode of Operation...................................................................9
[11] Skyroute CL3050 Configuration Options 1 .........................................................10
[12] Skyroute CL3050 Configuration Options 2 .........................................................11
[13] Skyroute CL3050 Trouble Output Mask ..............................................................11
[15] System Time ......................................................................................................13
[16] System Day ........................................................................................................13
[17] Test Transmission Time .......................................................................................13
[18] Test Transmission Day.........................................................................................13
[20] Transmission Options .........................................................................................13
[21] System Event Communication Options...............................................................15
[22] Input Supply Fail Tx Delay...................................................................................15
[23] Generic Zone Reporting Timer............................................................................15
Section 7: Programming Worksheets ............................................. 16
Glossary of Terms............................................................................. 19
Appendix A ...................................................................................... 20
ii
1 Introduction
1
1 Introduction
The Skyroute CL3050 is a standalone wireless communicator that sends alarm system infor-
mation to Connect 24. Connect 24 then forwards this information to the central station.
The Skyroute CL3050 automatically configures itself on power up to one of three opera-
tional modes or; if it is connected to a keypad, in the programming mode. The Skyroute
CL3050 is pre programmed with the most commonly used settings for quick installation. If
required the default options can be custom programmed.
Mode 1: Bell Follower
If the Skyroute CL3050 does not detect a keypad or PC5108 expander card dur-
ing the first 15 seconds of power up, then mode 1 or 2 can be selected by press-
ing the enroll button. The red LED indicates Mode 1 and the yellow LED indicates
mode 2. In Mode 1, the Skyroute CL3050 monitors the Bell Output of the con-
trol panel. The system identifies the Bell Output cadence and transmits the corre-
sponding Fire or Burglar alarm reporting code to Connect 24.
Refer to the appropriate control panel Installation Manual.
Mode 2: 2-Zone Panel
If Mode 2 is selected during power up the system will configure itself for 2 zone,
stand alone operation with normally closed loops.
Mode 3: 8-Zone Panel
If the Skyroute CL3050 detects a PC5108 expander card on power up it will auto-
matically configure itself for 8-zone standalone operation with normally closed
loops.
Programming Mode
If the Skyroute CL3050 detects a keypad on power up it will go into the program-
ming mode. Programming mode allows the installer to custom program system
options. Refer to Section 5, Programming Descriptions; and Section 6, Program-
ming Worksheets for programming options and default settings.
Note: The only method of entering the Programming Mode is to power-down the unit,
connect a PowerSeries keypad to the Keybus terminals, then reapply power to
the Skyroute CL3050.
Figure 1
Skyroute CL3050 Standalone Wireless Communicator
2
1.1 Specifications
Power Supply
Voltage...................................................................................... 9-12 VAC or VDC
Current.........................................................................................500 mA (Max)
Low DC Trouble ...................................................................................... 8.8 VDC
Low DC Restore ...................................................................................... 9.0 VDC
Low AC Trouble ...................................................................................... 7.5 VAC
Low AC Restore ...................................................................................... 8.0 VAC
Current Drain
Standby ................................................................................................. 100 mA
Receiving ............................................................................................... 150 mA
Transmitting........................................................................................... 850 mA
RF Power Output .......................................................................................... 600 mW
• Battery
Charging Voltage.................................................................................. 6.87 VDC
Low Battery Restore..............................................................................5.87 VDC
Low Battery Trouble ..............................................................................5.72 VDC
Critical Shutdown ................................................................................... 5.0 VDC
Operating Modes
Bell Follower
2-24Hr Zones
8-24Hr zones (with PC5108)
Event Buffer (communications)............................................. 32 Events (not viewable)
Dimensions ...................................................................................5 1/8” x 7 3/4” x 2”
Weight ............................................................................................... 0.5 lbs. (0.2Kg)
EEPROM Memory
Programmable by all PowerSeries Keypads
PC5508/KP5508Z ................................................................. 8 Zone LED keypad
PC5516Z/KP5516Z ............................................................. 16 Zone LED keypad
PC5532Z/KP5532Z ............................................................. 32 Zone LED keypad
LCD5500Z/KPL5500Z ................................ Programmable Message LCD Keypad
LCD5501Z/KP5501Z .................................................Fixed Message LCD Keypad
1.2 Unpacking
Verify that the following items have been included.
1 Skyroute CL3050 (rechargeable battery included)
1 Installation & Programming Guide
1 Antenna
4 Mounting screws
45.6 k
resistors
Remove antenna from protective bubble pack and install in unit.
Caution: Install antenna before connecting battery or power leads to this unit.
Transmission without an antenna can cause permanent damage.
Caution: When removing cover of this unit DO NOT touch or handle exposed
electrical devices and components. Electrostatic discharge (ESD) can
permanently damage this unit or reduce the reliability and life expect-
ancy of components.
2 Installation, Testing & Factory Defaults
3
2 Installation, Testing & Factory Defaults
2.1 Installation
1 Determine The Operating mode required (see section [03])
The operating mode (modes 1, 2, or 3) will determine how the unit is to be wired
up. Refer to section 6, Programming Descriptions, section [10] for available
options and for programming defaults.
2 Determine the Mounting Location
Select a mounting location in a dry, protected area. The mounting location
should be positioned so that it is at least 30 cm. away from physical contact with
any person.
Note: Do Not exceed the following recommendations for wire run distances
Keybus and zone wiring should be run using minimum 22 gauge quad
(0.5mm). Two pair twisted is preferred.
a keypad, PC5108, or zone wiring can not exceed 1,000'/305m (in wire
length) from the Skyroute CL3050.
Shielded wire is not necessary unless wires are run in an area that may present
excessive RF noise or interference.
•Refer to
section 6, Programming Descriptions, section [10] for zone wir-
ing details.
Note: Generally, the higher the location and the closer that the Skyroute
CL3050 is to an outside wall, the better the signal strength will be.
3Checking Signal Strength
Remove front cover
Connect Battery to the RED and BLK flying leads.
Connect AC Power source or 12 VDC to RED & BLK terminals.
Allow unit to power up
Note: The unit does not need to be enrolled with Connect 24 to check sig-
nal strength.
When the green LED stops flashing, press and release the enroll button.
Ensure that Radio Signal Strength Indication (RSSI) is greater than the mini-
mum acceptable level as indicated below. If the signal level is not accept-
able, reposition and retest the Skyroute CL3050 until an acceptable signal
strength is found.
Red LED Yellow LED Green LED Signal Strength
On
On
On
On
On
Flash
On
On
On
Flash
Off
Off
On
Flash
Off
Off
Off
Off
>87%
69-87%
*52-68%
34-51%
16-33%
0-15%
*Minimum recommended signal strength for enrollment
4 Route Wiring to Mounting Location
Route wiring from the hardwired zones or control panel as required.
Note: Route wiring through conduit to a junction box if possible. Mount the
Skyroute Panel.
Skyroute CL3050 Standalone Wireless Communicator
4
5 Mount Unit
Remove the front cover if required
Disconnect flying leads from battery and power leads from the RED and BLK
terminals (if connected).
Remove two screws securing battery clamp. Remove battery
Mount backplate of unit to wall or over electrical junction box using the
four screws provided.
Note: DO NOT connect the battery to the flying leads and AC or DC power
to the terminal strip until all other wiring connections are completed.
Route wiring through the access holes provided and connect to terminal
strip.
power up unit by connecting battery and power source.
6 Enroll Unit
Call Connect 24 and Enroll the Skyroute CL3050. Refer to page (ii) for contact
information and a list of information required to complete the enrollment with
the Connect 24 Voice Response Unit.
2.2 Te s t i n g
Program Mode: If you have wired the unit to power up in the programming
mode. Follow the steps outlined in Section 6, Programming Descriptions and
record the program settings in Section 7, Programming Worksheets.
Test Transmission - Pressing and holding the enroll button for 2 seconds will
send a test transmission to the central station via Connect 24. Refer to Enrol
Button in Section 3, Controls and indicators for test transmission details.
Mode 1: Disable the telephone line connected to the control panel. Simulate
Burglar and Fire Zone violation. Verify that the Skyroute CL3050 transmits the
events to the central station.
Mode 2 & 3: Simulate Faults, Tampers, and Zone violations in accordance with
the settings outlined in Sections 6, Programming Descriptions. Verify that the
Skyroute CL3050 transmits the events to the central station.
2.3 Resetting to Factory Defaults
Note: Resetting to factory defaults is required to change mode of operation.
Remove Power from the Skyroute CL3050; disconnect battery and control
panel if applicable (mode 1).
Disconnect all wiring from the YEL and GRN terminals.
Connect a jumper wire between the YEL and GRN terminals.
Apply power to the system.
Note: When the hardware default has been completed; the yellow, green
and red LEDs will flash on and off continuously.
Remove power from the system.
Note: To resume communications with Connect 24, Section [11], Option 6
must be set to ON. To do this; the system must be powered up in pro-
gramming mode. Refer to Section 5 System Programming.
Reconnect all original wiring and reapply power to the system.
Test System - Refer to Section 2.2
3 Controls and Indicators
5
3 Controls and Indicators
Figure 2
3.1 LED Indicators (see figure 2)
Yellow LED
During normal operation, the yellow LED will indicate the system status with a
series of flashes as indicated below.
No. of
Flashes Indication
1
2
3
4
5
6
7
8
9
No trouble conditions present
Low battery
Input supply failure
Not enrolled at Connect 24
No service available*
Radio failure
PC5108 failure
Failure to communicate
Zone tamper/fault trouble
Enroll Button
Battery (6 V )
DC
Green LED
Yell ow LE D
Red LED
Ta mper Sw i tc h
Mounting Holes
Wire Access
Antenna
Skyroute CL3050 Standalone Wireless Communicator
6
Note: Multiple trouble conditions are displayed (flashed) in sequence.
Red LED
The red LED will flash to provide event transmission status for the following
events:
1 Flash
1 Flash
2 Flashes
Enroll button held down for 2 seconds
Event transmitted to cellular network
Event acknowledged by Connect 24.
Green LED
The green LED will light continuously if the (RSSI) signal is acceptable. If signal
strength is not acceptable the LED will turn OFF. Detailed information on signal
strength can be accessed by momentarily pressing and releasing the enroll
button. The green, yellow and red LEDs will light to indicate the range of signal
strength. Refer to Section 2 Step 3.
3.2 Enroll Button (see figure 2)
The Skyroute CL3050 Enroll button is located on the outside of the plastic hous-
ing directly below the status LEDs. The enroll button performs three functions.
Pressing this button during the first 15 seconds of power up will toggle
between Mode 1 and Mode 2 to enable mode selection.
Pressing and releasing this button momentarily at any time after the power
up sequence will display the detailed RSSI status indicated above.
Holding this button down for a period of 2 seconds continuously will cause
the Skyroute CL3050 to send a test transmission to Connect 24, this long
debounce will be indicated to the user by the red LED flashing once.
3.3 Terminal Connections (see figure 2)
RED 9-12VDC Positive Input or 9-12VAC
Note: 12VDC is required for programming or for operation with a
PC5108 zone expander. Mode 1 and Mode 2 may be operated
with an AC Supply.
BLK 9-12VDC Ground or 9-12VAC
YEL Mode 1 - The YEL terminal functions as the Bell input.
Mode 2 - This terminal functions as the zone 1 input.
Mode 3 - This terminal connects to the YEL Keybus terminal when
using a PC5108 zone expander or PowerSeries keypad.
GRN Mode 1 - The GRN terminal functions as the TLM Trouble input.
Mode 2 - This terminal functions as the zone 2 input.
Mode 3 - This terminal connects to the GRN Keybus terminal when
using a PC5108 zone expander or PowerSeries keypad.
COM Mode 1 - This terminal functions as the common terminal for the Bell
Input on the YEL terminal, the TLM trouble input on the GRN terminal
and the Trouble Output on the PGM terminal.
Mode 2 - This terminal functions as the common terminal for zone 1
(YEL) and zone 2 (GRN).
Mode 3 - This terminal functions as the common terminal for the
Trouble Output
4 Power up Sequence
7
PGM - The PGM output is
dedicated for Skyroute
CL3050 trouble indica-
tions. If a control panel is
not monitoring the Sky-
route CL3050, an LED or a
buzzer can be connected
between this terminal and
the RED terminal for trouble
indication. The PGM termi-
nal switches low from an
open-collector state. Con-
nect to the control panel
using a Single EOL configu-
ration as shown
Note: The PGM output can
sink 50 mA (maximum).
4 Power up Sequence
On first-time power up, the Skyroute CL3050 will generate a random test trans-
mission time and random day of the week to send it. The installer can then
change this information if required.
During power up, the Skyroute CL3050 will look for a keypad on the Keybus, if
one is found, it will go into programming mode. If no keypad is found, it will
look for a PC5108 zone expander module. If a zone expander is found, it will
automatically configure itself for mode 3. If no Keybus modules are present, the
Skyroute CL3050 will power up in mode 1. During the first 15 seconds of power
up, any zone scanning will be shunted. During this time the installer can momen-
tarily press the enroll button on the Skyroute CL3050 to toggle between mode 1
and mode 2. Upon power up the green LED will be flashing on and off. This will
indicate to the installer that he/she can change the mode to 1 or 2. The red LED
will indicate mode 1 and the yellow LED will indicate mode 2. If neither red or yel-
low LED is lit, then the Skyroute CL3050 has detected a PC5108 module, the
mode cannot be changed by pressing the enroll button if a PC5108 module is
connected to the Skyroute CL3050.
If a keypad is detected on Keybus, the green LED will stop flashing, and the red
LED will begin flashing to indicate that programming mode is active.
RED BLK YEL GRN COM PGM
LED 560
LED Output with
current limiting
resistor
Optional relay
driver output
+ Coil -
Relay
To External
Supply
NC Com
Skyroute CL3050
Skyroute CL3050 Standalone Wireless Communicator
8
5 System Programming
The Skyroute CL3050 is programmed using a PowerSeries keypad. Refer to
Section 1.1 Specifications.
Note: Power down the Skyroute CL3050 when connecting or removing
other Keybus modules from the system. If the Skyroute CL3050 is con-
nected to a control panel (mode 1), the control panel must also be
powered down.
1. Connect keypad Keybus connections to the RED, BLK, YEL and GRN termi-
nals of the Skyroute CL3050.
2. Connect a +12VDC supply across the RED and BLK terminals.
Upon detecting the keypad on power up, the Skyroute CL3050 will begin
driving Keybus and will blank the keypad with all LEDs and icons off.
3. Press the star [*] key to gain access to the programming section.
Programming is done with a 2-digit section entry. When programming is
complete, power down the Skyroute CL3050 and remove the keypad.
To Keybus
Connections
on Keypad
Not Connected
RED BLK YEL GRN COM PGM
6 Programming Descriptions
9
6 Programming Descriptions
[01] Zone 1, 2 Definitions Modes 2, 3
When the Skyroute CL3050 is in Mode 2 or 3, there are 14 options that can be
programmed as zone types. All of the zone types with the exception of 00 (null
zone) and 13 (TLM monitor) are straightforward. Since all the zones are 24-hour
type zones, selecting any listed zone type will simply select which identifier
should be used for reporting the alarm. Programming a zone as 00 (null zone)
will disable the zone input on the Skyroute CL3050 or PC5108 hardware. Pro-
gramming any zone as type 13 will disable all communications unless that zone
input is closed (short condition).
Note: Do NOT program more than 1 TLM zone type on the Skyroute
CL3050.
Default - [01] zones 1 & 2
[02] Zone 3 - 8 Definitions Mode 3
This allows programming of the six additional zone definitions when operating in
mode 3 with a PC5108 zone expander. See section [01] for details
Default - [01] zones 3 - 8
[03] Zone 1, 2 Loop Response Modes 2
This entry determines how quickly a zone will respond to changes in state.
Note: This does not affect zones on a PC5108 zone expander card.
Default - 05 (0.5 seconds) 01-FF Hex x 0.1 seconds.
[10] Skyroute CL3050 Mode of Operation
[01] Mode 1 - Bell Follower Operation
In this mode, the YEL terminal is con-
nected to the bell output of a control
panel. The Skyroute CL3050 moni-
tors the output for burglary and fire
cadences and transmits the appropri-
ate events. For any type of pulsed
cadence, the Skyroute CL3050 will
send a generic Fire event, for any
steady bell the Skyroute CL3050 will
send a generic Burglary event. The GRN terminal is a trouble input which can be
connected to a system output to alert the Skyroute CL3050 of a system TLM
fault. This will enables the Skyroute CL3050 to be used as a back-up communi-
cator only. If not used, this input must to connected to COM. The bell
cadence will be determined as follows:
Bell must be on for longer then 300mS to be considered a "pulse"
Bell must be on for 3 seconds continuous to be considered "steady"
Bell must be off for 3 seconds continuous to be considered "silenced"
Bell must pulse on and off 3 times to be considered "pulsed", 3rd off-time
will trigger event
Bell Report Code Group
Pulsed
Steady
FA98
BA98
Fire
Burglary
Input Voltage
9-12V or V
AC DC
Bell Input
TLM Input
System Common
Trouble Output
RED BLK YEL GRN COM PGM
Skyroute CL3050 Standalone Wireless Communicator
10
[02] Mode 2 - (2) 24-Hour Zones
In this mode, both the YEL and
GRN terminals on the Skyroute
CL3050 will be used as zone
inputs. These zones will support
the DSC standard EOL configura-
tion and loop response. Pro-
gramming sections will allow the
installer to change the default
zone types and attributes. The
Skyroute CL3050 will continu-
ously monitor these zones and transmit any alarms that occur to the central sta-
tion.
[03] Mode 3 - (8) 24-Hour Zones
In this mode, the Skyroute
CL3050 is connected to a
PC5108 zone expander using
the corresponding RED, BLK,
YEL and GRN terminals. The
Skyroute CL3050 will drive the
Keybus to communicate with
the PC5108. A +12VDC sup-
ply connected to the RED and
BLK terminals is required
when using this mode. The Programming sections will allow the installer to
change the default zone types and attributes. The Skyroute CL3050 will continu-
ously monitor these zones and transmit any alarms that occur to the central
station.
Note: This configuration can not be used with an AC supply.
Note: Jumpers on the PC5108 must be set as follows:
J1
J2
J3
ON
OFF
ON
J4
J5
J6
OFF
OFF
ON
Default - [01 -03] dependant on start up configuration
[11] Skyroute CL3050 Configuration Options 1
Option 1 - A Channel Selected/ B Channel Selected. All Modes
This Option determines whether cellular channel “B” or channel “A” is used. In
Canada, Channel B is used (Default). In the USA refer to the SID list for the chan-
nel of the cellular service provider in your area. Default - Channel B
Option 2 - Normally Closed Loops/ End-of-line Resistors Mode 2, 3
Normally Closed Loops can be wired as shown. Multiple
Normally Closed contacts can be wired in series. For Double
or Single EOL resistors this option must be set to OFF
.
Default - Normally Closed (N/C) Loops.
Option 3 - Double EOL Resistors/Single EOL Resistors Mode 2, 3
This option selects Double EOL resistors (ON) or Single EOL resistors (OFF) wired
as indicated
Input Voltage
9-12V or V
AC DC
Zone 1 Input
Zone 2 Input
Zone Common
Trouble Output
RED BLK YEL GRN COM PGM
To Keybus
Connections
on PC5108
System Common
Trouble Output
RED BLK YEL GRN COM PGM
6 Programming Descriptions
11
Single EOL resistors allows the use
of N/C and/or Normally Open contacts.
Double EOL resistors allows the
zone to be monitored for fault,
tamper, secure and violated condi-
tions. Only Normally Closed contacts
can be used in this configuration
Note: Option 2 must be set to OFF to enable these options.
Default - OFF
Option 4 - Test Once a Day Enabled/Disabled All Modes
Allows transmission test daily. Default - Disabled.
Option 5 - Test Once a Week Enabled/Disabled All Modes
Allows transmission test weekly.
Note: This option will be overridden If option 4 is set for daily test transmissions.
Default - Enabled.
Option 6 - Enrolled with Connect 24 /Not Enrolled All Modes
This option is set automatically during the enrollment procedure with
Connect 24. IF the Skyroute CL3050 is reset to the default settings this option
must be set to ON for the Skyroute CL3050 to resume communications.
Default - Not Enrolled.
Options 7, 8 - System Use All Modes
Caution: Do NOT change these settings unless it is requested by DSC
technical support personnel.
Default - OFF.
[12] Skyroute CL3050 Configuration Options 2
Option 1 - Swinger Shutdown Enabled/Disabled Modes 2, 3
This option limits the number of alarm events transmitted per zone to 8 until the
counter has been reset (counter automatically resets at midnight), then event
transmissions will resume. Default - Enabled
Note: Tampers and Faults will be counted unless they are disabled in
section [20].
[13] Skyroute CL3050 Trouble Output mask All Modes
The PGM output is dedicated for trouble indications. If a control panel is not
monitoring the Skyroute CL3050, an LED or a buzzer can be connected between
this terminal and the RED terminal for a trouble indication. The PGM terminal
switches low from an open-collector state. Connect to the control panel using a
single EOL resistor configuration.
5.6K
C Zx
5.6K
C Zx
5.6K
C Zx
5.6K
Tam p er
Contact
C Zx
5.6K
5.6K
5.6K
C Zx
Skyroute CL3050 Standalone Wireless Communicator
12
.
Note: A relay may be required for proper operation in other configurations.
See paragraph 3.3 Terminal Connections.
Option 1 - Low battery All Modes
If the battery voltage drops below 5.72VDC a trouble will be indicated until the
battery voltage rises to 5.87VDC. Default - ON
Option 2 - Input Supply Failure All Modes
If AC power is absent or if DC power drops below 8.8VDC on the RED and BLK
terminals, this trouble is indicated. Default - ON
Option 3 - Zone Fault/Tamper (DEOL Only) Modes 2, 3
A trouble will be indicated if any zone reports a fault or tamper condition. In Sec-
tion [11], Option [2] must be set to OFF and Option [3] must be set to ON for this
option to be enabled. Default - OFF
Option 4 - No Service Available All Modes
This trouble is indicated If the system is unable to detect cellular service.
Default - ON
Option 5 - Radio Failure All Modes
This trouble is indicated if there is an internal fault with the cellular radio.
Default - ON
Option 6 - PC5108 Failure Mode 3
This trouble is indicated if a PC5108 supervisory or Keybus fault occurs.
Note The PC5108 tamper is communicated only, therefore it can only be
enabled by turning on section 20 option 7 and section 21 option 5.
There is no local annunciation for this event.
Default - ON
Option 7 - Failure to Communicate (FTC) All Modes
This trouble will be indicated if no acknowledgement has been received from
Connect 24 after three attempts. Default - ON
Option 8 - Skyroute CL3050 Tamper All Modes
This trouble will be indicated if the cover is removed from the Skyroute CL3050
activating the on-board tamper switch. Default - OFF
Zx COM
Control Panel
RED BLK YEL GRN COM PGM
5.6K
Skyroute CL3050
6 Programming Descriptions
13
[15] System Time All Modes
When the time and day have been programmed, the values are saved and are
used as the current time and day whenever the Skyroute CL3050 does a power
up. Time and day programming is only required if the installer desires the Sky-
route CL3050 to test transmit at a specific time and/or day. There is no "loss of
time" trouble on the Skyroute CL3050.
Default - 0000 - 2359
Note If AC Power is detected, it will be used to provide the time base for the
internal clock. If AC power is not detected the internal clock will auto-
matically use the crystal time base.
[16] System Day of the Week All Modes
See section [15].
Option 1. Default - ON
Option 2 - 8. Default - OFF
[17] Test Transmission Time All Modes
When the Skyroute CL3050 is powered up for the first time, or after a default
reset; it will check if the test transmission time and day are programmed. If they
are not, a random time (0000 - 2359) will be programmed into this location. The
Skyroute CL3050 will randomly generate this value.
Note: Due to traffic volume, when selecting test transmission times, select a
time that is not on the :30 minute mark (e.g., 02:24, 04:07).
[18] Test Transmission Day All Modes
When the Skyroute CL3050 is powered up for the first time, or after a default, it
will check if the test transmission time and day are programmed. If they are not,
a random day (Sunday-Saturday) will be programmed into this location. The Sky-
route CL3050 will randomly generate this value. Because one test transmission
weekly is the most common configuration, this will allow the installer to setup
the Skyroute CL3050 without keypad programming.
Option 1-8. Default - [Random] - One only will be enabled.
[20] Transmission Options All Modes
When the following options are enabled the reporting codes listed in Appendix A
are sent to Connect 24.
Options 1, 2 - Zone Alarm/Zone Alarm Restores Modes 2, 3
When a zone is violated or restored, the reporting codes listed in Appendix A will
be sent.
Note: If generic reporting is enabled and multiple alarms occur during the
delay programmed in Section [23], only one alarm reporting code will
be sent.
Note: Zone alarm restorals enabled with generic zone reporting enabled can
cause unpaired events to be sent to Connect 24.
Option 1. Default - ON, Option 2. Default - OFF
Skyroute CL3050 Standalone Wireless Communicator
14
Options 3, 4 - Zone Fault, Zone Fault Restores Modes 2, 3
When the system sees a short circuit across any zone, a zone fault is generated.
DEOL resistors are required for zone fault reporting. In Section [11], Option [2]
must be set to OFF and Option [3] must be set to ON; In Section [13], Option 3
must be set to ON and the Skyroute CL3050 must be operating in mode 2 or 3.
Option 3. Default - OFF
, Option 4. Default - OFF
Options 5, 6 - Zone Tamper, Zone Tamper Restores Modes 2, 3
When the system sees an open circuit across any zone a zone tamper is gener-
ated. DEOL resistors are required for zone tamper reporting. In Section [11],
Option [2] must be set to OFF and Option [3] must be set to ON. In Section [13],
Option [3] must be set to ON and the Skyroute CL3050 must be operating in
mode 2 or 3.
Option 5. Default - OFF, Option 6. Default - OFF
Option 7 - System Maintenance Events All Modes
When this option is enabled, the maintenance events enabled in Section [21] are
transmitted using the codes listed in appendix A.
Default - ON,
Option 8 - Generic Zones Modes 2, 3
The Skyroute CL3050 supports generic and detailed zone alarm reporting. By
default, the Skyroute CL3050 will be in generic zone reporting mode. When in
this mode, all zone types are divided into four reporting groups; BA Burg, FA Fire,
PA Panic, UA Technical. If any zone from this group initiates a transmission, the
generic reporting code for this event is sent, additional violations from other
zones from the same group will be ignored until that group's timer has expired.
See table below for zone type grouping.
Zone
Typ e
Detailed
Reporting Code
Generic
Reporting Code
Null
Burglary
Fire
Panic
Technical
Gas
Heat
Medical
Emergency
Water
Freezer
Sprinkler
Hold-up
-
BA
FA
PA
UA
GA
KA
MA
QA
WA
ZA
SA
HA
-
BA
FA
PA
UA
UA
FA
PA
PA
UA
UA
UA
PA
Each zone group has it's own timer. The default time is 5 minutes and is pro-
grammed in Section [23]. If any zone in a group initiates an event, the timer will
start running and the generic event will be sent. If any additional zones from the
same group initiate an event before that group's timer expires, the event will be
ignored. This generic zone reporting mode only applies to zone alarms. Alarm
restorals, tamper/tamper restorals and fault/fault restorals are not grouped
together into generic reporting groups.
6 Programming Descriptions
15
The generic identifier will be sent with 98 as it's zone number, this is a special
combination recognized by Connect 24 as a generic event. When the generic
zone reporting toggle is disabled, each zone alarm for each zone type will then
send it's own identifier. Default - ON.
[21] System Event Communication Options
NOTE: Section [20], Option [7] must be enabled for these events to be communicated.
Option 1 - Input Supply Failure All Modes
If AC power is absent or if DC power drops below 8.8VDC on the RED and BLK
terminals, a trouble will be sent after the delay programmed in section [22] has
expired. Default - ON,
Option 2 - Low Battery All Modes
If the battery voltage drops below 5.72VDC a trouble will be sent to Connect 24.
When the battery voltage rises to 5.87VDC the system will send a restore.
Default - ON.
Option 3 - Skyroute CL3050 Tamper All Modes
Removing the cover on the Skyroute CL3050 will send a tamper reporting code
to Connect 24. Default - OFF
.
Option 4 - PC5108 Module Fault Mode 3
Indicates a Keybus communications fault condition.
Default - OFF.
Option 5 - PC5108 Tamper Mode 3
Removing the cover on the PC5108 will send a tamper reporting code to Con-
nect 24. Default - OFF.
[22] Input Supply Fail TX Delay All Modes
This value determines the delay (default 0700 = 7 hrs) before an input supply fail-
ure reporting code is sent if programmed. See Section [21], Option [1] and Sec-
tion [20], Option [2]. Default - 0700 (=7 hrs)
[23] Generic Zone Reporting Timer Modes 2, 3
This hex value determines the delay before a generic zone reporting code is sent,
if programmed in Section 20 Option 8.
Note: There are four separate timers for Burglary, Fire, Panic and Supervisory;
the delay programmed is the same for each timer.
Default - 1E (300 seconds / 5 minutes) Range equals 01-FF Hex seconds x 10
Skyroute CL3050 Standalone Wireless Communicator
16
7 Programming Worksheets
Zone Definitions (For Sections [01] -[02])
00 Null Zone (Not Used)
01 Burglary
02 Fire
03 Panic
04 Technical
05 Gas
06 Heat
07 Medical
08 Emergency
09 Water
10 Freeze
11 Sprinkler
12 Hold-up
13 TLM Monitor (1 zone max.)
[01] Zone 1-2 Definitions
Default Default
01 I___I___I Zone 1 01 I___I___I Zone 2
[02] Zone 3-8 Definitions
Default Default
01 I___I___I Zone 3 01 I___I___I Zone 4
01 I___I___I Zone 5 01 I___I___I Zone 6
01 I___I___I Zone 7 01 I___I___I Zone 8
[03] Zone 1-2 Loop Response 01-FF (Hex 0.1 second increments), mode 2 only
Default Default
05 I___I___I Zone 1 05 I___I___I Zone 2
[10] Skyroute CL3050 Mode of Operation
Default
01 I___I___I 01 - Bell Follower, 02 - 2 Zone, 03 - 8 zone (PC5108 )
[11] Skyroute CL3050 Configuration Options 1
Default Opt Option On Option Off
OFF I___I 1A Channel selected B Channel selected
ON I___I 2Normally Closed Loops End-of-Line Resistors
OFF I___I 3Double End-of-Line Resistors Single End-of-Line Resistors
OFF I___I 4Test Once a Day Enabled Disabled
ON I___I 5Test Once a Week Enabled Disabled
OFF I___I 6Enrolled with Connect 24 Not Enrolled with
Connect 24
OFF I___I 7 System Use - Caution: Do not change
OFF I___I 8 System Use - Caution: Do not change
[12] Skyroute CL3050 Configuration Options 2
Default Opt Option On Option Off
ON I___I 1 Swinger Shutdown Enabled Swinger Shutdown Disabled
ON I___I 2-8 For Future Use
7 Programming Worksheets
17
[13] Skyroute CL3050 Trouble Mask
Default Opt Option On Option Off
ON I___I 1Low Battery Disabled
ON I___I 2Input Supply Failure Disabled
OFF I___I 3Zone Fault/Tamper (DEOL only) Disabled
ON I___I 4No Service Available Disabled
ON I___I 5Radio Failure Disabled
ON I___I 6PC5108 Failure Disabled
ON I___I 7Failure to Communicate Disabled
OFF I___I 8Skyroute CL3050 Tamper Disabled
[15] System Time
Default Range
0000 I___I___I___I___I 0000-2359 Hrs/Mins
[16] System Day
Default Opt Option On Option Off
ON I___I 1Sunday Disabled
OFF I___I 2Monday Disabled
OFF I___I 3Tuesday Disabled
OFF I___I 4Wednesday Disabled
OFF I___I 5Thursday Disabled
OFF I___I 6Friday Disabled
OFF I___I 7Saturday Disabled
OFF I___I 8 For Future Use
[17] Test Transmission Time
Default Range
Random I___I___I___I___I 0000-2359 Random on power up
[18] Test Transmission Day *Selected at random on power up
Default Opt Option On Option Off
* I___I 1Sunday Disabled
* I___I 2Monday Disabled
* I___I 3Tuesday Disabled
* I___I 4Wednesday Disabled
* I___I 5Thursday Disabled
* I___I 6Friday Disabled
* I___I 7Saturday Disabled
* I___I 8For Future Use
7 Programming Worksheets
18
[20] Transmission Options
Default Opt Option On Option Off
ON I___I 1Zone Alarms Disabled
OFF I___I 2Zone Alarm Restores Disabled
OFF I___I 3Zone Fault Disabled
OFF I___I 4Zone Fault Restores Disabled
OFF I___I 5Zone Tamper Disabled
OFF I___I 6Zone Tamper Restores Disabled
ON I___I 7System Maintenance Events Disabled
ON I___I 8Generic Zone Reporting Detailed Zone Reporting
[21] System Event Communication Options
Default Opt Option On Option Off
ON I___I 1Input Supply Failure Disabled
ON I___I 2Low Battery Disabled
OFF I___I 3Skyroute CL3050 Tamper Disabled
OFF I___I 4PC5108 Module Fault Disabled
OFF I___I 5PC5108 Tamper Disabled
OFF I___I 6-8 For Future Use
[22] Input Supply Fail TX Delay
Default Range
0700 I___I___I___I___I 0000-2359 Hrs/Mins
Glossary of Terms
19
Glossary of Terms
Cellemetry A network allowing short data packets to be sent on cellular control
channels.
Connect 24 Connect 24 is the service provider that provides the Skyroute service to
the security industry and links the Skyroute cellemetry communicator
to the central station.
RSSI Radio Signal Strength Indication - This value is transmitted to Connect
24 during the periodic test transmission and can be viewed after
power up by pressing the enroll button.
SID System Identification Number - ID Number of the Cellular provider
MIN Mobile Identification Number - The 10 digit decimal number used for
registrations and pages (the phone number of the Skyroute CL3050).
Page A transmission that is sent from the Cellemetry Gateway to the Cel-
lemetry Radio
Registration A transmission that is sent from the Cellemetry Radio to the Cellemetry
Gateway
Skyroute CL3050 Standalone Wireless Communicator
20
Appendix A: Reporting Codes
Events Reporting Codes Events Reporting Codes
SIA Contact
ID
SIA Contact
ID
Zone Alarms Zone Restores
Burglary Zone BAXX E130 Burglary Zone BHXX R130
Fire Zone FAXX E110 Fire Zone FHXX R110
Panic Zone PAXX E120 Panic Zone PHXX R120
Technical Zone UAXX E140 Technical Zone UHXX R140
Gas Zone GAXX E151 Gas Zone GHXX R151
Heat Zone KAXX E158 Heat Zone KHXX R158
Medical Zone MAXX E100 Medical Zone MHXX R100
Emergency Zone QAXX E120 Emergency Zone QHXX R120
Water Zone WAXX E154 Water Zone WHXX R154
Freezer Zone ZAXX E140 Freezer Zone ZHXX R140
Sprinkler Zone SAXX E110 Sprinkler Zone SHXX R110
Hold-up Zone HAXX E122 Hold-up Zone HHXX R122
Zone Fault Alarms Zone Fault Restores
Burglary Zone UTXX E300 Burglary Zone UJXX R300
Fire Zone FTXX E373 Fire Zone FJXX R373
Panic Zone UTXX E300 Panic Zone UJXX R300
Technical Zone UTXX E300 Technical Zone UJXX R300
Gas Zone UTXX E300 Gas Zone UJXX R300
Heat Zone UTXX E300 Heat Zone UJXX R300
Medical Zone UTXX E300 Medical Zone UJXX R300
Emergency Zone UTXX E300 Emergency Zone UJXX R300
Water Zone UTXX E300 Water Zone UJXX R300
Freezer Zone UTXX E300 Freezer Zone UJXX R300
Sprinkler Zone STXX E200 Sprinkler Zone SJXX R200
Hold-up Zone UTXX E300 Hold-up Zone UJXX R300
Appendix A: Reporting Codes
21
Event Reporting Code Event Reporting Code
SIA Contact
ID
SIA Contact
ID
Zone Tamper Alarms Zone Tamper Restores
Burglary Zone TAXX E137 Burglary Zone TRXX R137
Fire Zone FTXX E373 Fire Zone FJXX R373
Panic Zone TAXX E137 Panic Zone TRXX R137
Technical Zone TAXX E137 Technical Zone TRXX R137
Gas Zone TAXX E137 Gas Zone TRXX R137
Heat Zone TAXX E137 Heat Zone TRXX R137
Medical Zone TAXX E137 Medical Zone TRXX R137
Emergency Zone TAXX E137 Emergency Zone TRXX R137
Water Zone TAXX E137 Water Zone TRXX R137
Freezer Zone TAXX E137 Freezer Zone TRXX R137
Sprinkler Zone STXX E200 Sprinkler Zone SJXX R200
Hold-up Zone TAXX E137 Hold-up Zone TRXX R137
Generic Zone Events System Events
Generic Burglary BA98 E130
98
Input Supply Fail
Trouble
YP00 E312
Generic Fire FA98 E110
98
Input Supply Fail
Restore
YQ00 R312
Generic Panic Zone PA98 E120
98
Low Battery Trouble YT00 E302
Generic Supervisory UA98 E140
98
Low Battery Restore YR00 R302
Skyroute CL3050
Tamper Alarm
TA00 E137
Skyroute CL3050
Tamper Restore
TR00 R137
PC5108 Tamper Alarm TA00 E330
PC5108 Tamper Restore TR00 R330
PC5108 Supervisory
Trouble
ET00 E330
PC5108 Supervisory
Restore
ER00 R330
Periodic Test
Transmission
TXZZ E603
©2002 Digital Security Controls Ltd.
Toronto • Canada • 1-800-387-3630
www.dsc.com
Printed in Canada 29034531r001
Forward comments about this manual to: pubs@dsc.com

Navigation menu