WS4945Wireless Door/Window ContactPowering the WS4945For your added convenience, the WS4945 comes with the battery pre-installed. To activate, hold theWS4945 firmly in one hand and pull the plastic tab in the direction indicated.Locate TransmitterSelect the location where the WS4945 is to be mounted.  NOTE: RF signals can be affected by metalobjects, including metal doors or large mirrors. Such locations should be avoided as they can interferewith proper operation. Enrolling, Programming and PlacementEnroll the WS4945 by programming the 6-digit serial number (located on the WS4945) into the receiver.Once the WS4945 is enrolled, you must perform a Module Placement test to ensure the location you havechosen is suitable. Please refer to your receiver Installation Manual for details. Mounting the WS4945 and MagnetOnce you determine the proper location (see Enrolling, Programming and Placement), the WS4945 can bepermanently mounted. NOTE: It is the responsibility of the installer to ensure that the WS4945 issecurely mounted in the intended location.Using Provided Screws: Remove the back from the transmitter. Mount the back housing of the WS4945,using the screws supplied, to the desired location.Using Adhesive Tape: Ensure that the surface is clean and dry. Apply the tape to the back of the WS4945,press and hold firmly in the desired location for approximalty 10-15s. It can take up to 24h for the tape toreach maximum bonding strength.Align the magnet with the notched arrow    on the WS4945 housing (see Figure C). Mount the magnet amaximum of 5/8" (1.8cm) from the WS4945 by using the provided tape or screws. If necessary use thespacers provided. Once the WS4945 and magnet are mounted, open and close the window/door to ensurethat none of the parts interfere with this movement. Only one magnet can be used for each WS4945.NOTE: The adhesive tape is not to be used in UL Installations.   Using External ContactsThe external contact terminals can be used to connect external contacts or other switches/devices to the uni-versal transmitter. Install the additional device as per the manufacturer instructions. Connect the device tothe contact terminals of the WS4945. The input is normally closed and is not supervised.For all installations, the wires connecting the external device to the input terminals must not exceed 16" (40cm) in length, provided that the resistance of the wire does not exceed 100 Ohms. The contact and transmit-ter must also be in the same room. Only one contact can be used. If an external contact is used, do notinstall the magnet.Tamper SwitchOut of the box the WS4945 comes equipped with case tamper detection. If the case is removed, theWS4945 will report a zone tamper to the control panel. For added security the WS4945 was designed toprovide wall tamper monitoring as well. Simply replace the short rubber actuator (see Figure D) with thelonger one that is included. With this option, if the case is opened or if the WS4945 is removed from it'slocation, a tamper will be sent to the control panel. It is strongly recommended that mounting screws beused when using the wall tamper option.Replacing the BatteryTo replace the battery, insert a flathead screwdriver into either side of the unit and carefully twist to separatethe top and bottom plastic (see Figure A). Once separated, the battery will be visible (please refer to FigureB). Remove the old battery and install new battery, observing correct polarity. WARNING!: Batterymay explode if mistreated. Do not recharge, disassemble or dispose of in fire.SpecificationsDimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75mmx31mmx22mm (2.9”x1.2”x0.87”)OperatingTemperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 to 49oC (32 to 120oF)Operating Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 to 93% RHOperating Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433MHzBattery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Tekcell/Panasonic CR2 LithiumBattery Life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-8 years** Not tested by UL/ULCCompatible with PC5132-433, PC4164-433, NT9005-433, RF5501-433, RF5108-433Installation InstructionsWS4945Contact miniature pour Porte/FenêtreMise en marche du WS4945Pour vous faciliter la tâche, le WS4945 est livré avec la pile préinstallée. Pour activer, tenir fermement leWS4945 dans une main, et tirer la languette en plastic dans la direction indiquée.Emplacement de le WS4945Choisissez l’emplacement ou le WS4945 sera installé. REMARQUE : Le signal RF peut être affecté par desobjets métalliques tels que des portes en métal ou des miroirs importants. Ce genre d’emplacement doitêtre évité car ces objets peuvent interférer avec le bon fonctionnement du dispositif.  Attribution, Programmation et EmplacementAttribuer le WS4945 en programmant le récepteur avec le numéro de série à 6 chiffres (situé sur le WS4945).Une fois que le WS4945 est attribué, vous devez effectuer un essai de placement de module pour assurer quel'emplacement choisi convient. Pour de plus amples renseignements, veuillez consulter le manuel d'installationde votre récepteur.Installation de le WS4945 et de l'aimantUne fois que vous avez déterminé un emplacement approprié (voir Attribution, Programmation, Placement) leWS4945 peut être fixé de manière permanente. NOTE: Il est de la responsabilité de l'installateur des'assurer que le WS4945 est solidement monté dans l'endroit prévu.Avec les vis fournies : Retirez la plaque arrière de le WS4945. Fixez, a l’emplacement désiré, la plaque arrièredu coffret de le WS4945 avec les vis fournies. Avec le ruban adhésif double face : Assurez vous que la surface est propre et sèche. Mettez le ruban au dos duWS4945, appuyez et maintenez fermement à l’emplacement désiré pendant environ 10 à 15 secondes. Le rubanadhésif peut prendre 24 h pour atteindre son adhésivité maximum.Aligner l'aimant sur la flèche   encochée sur le coffret de le WS4945 (voir Figure C). Installez l'aimant à unedistance maximum de 1,8 cm (5/8 po) de le WS4945 en utilisant le ruban adhésif ou les vis. Si nécessaire, uti-liser les entretoises fournies. Une fois le WS4945 et l'aimant installés, ouvrez et fermez la porte/fenêtre pourassurer qu'aucun des éléments du WS4945 n'entrave ce mouvement. Un seul aimant peut être utilisé parWS4945.  REMARQUE : Le ruban adhésif ne doit pas être utilisé dans les installations UL.Usage d’un contact externeLes bornes de contact externe peuvent être utilisées pour raccorder des contacts ou d’autres dispositifs externes autransmetteur universel. Installez les dispositifs additionnels en suivant les instructions du fabricant. Raccordez ledispositif aux bornes pour contact externe du WS4945. L’entrée est normalement fermée et n’est pas supervisée.Pour tous les installations, la longueur du fil utilisé pour raccorder le dispositif externe aux bornes d’entrée ne doitpas excéder 16" (40cm), pourvu que la résistance du fil n’excède pas 100 Ohms. Le contact et le transmetteurdoivent également être dans la même pièce. Un seul contact peut être utilisé; si un contact externe est utilisé,n’installez pas l’aimant du transmetteur.Interrupteur de sabotageLe dispositif WS4945 est fourni avec un coffret de détection de sabotage. Si le coffret est retiré, le WS4945 enverraune signalisation de sabotage au panneau de contrôle. Pour une plus grande sécurité, le WS4945 a également étéconçu pour fournir une surveillance de sabotage mural. Remplacez simplement le court déclencheur en caoutchouc(voir Figure D) avec le plus long qui est fourni. Avec cette option, si le coffret est ouvert ou si le WS4945 est retiréde son emplacement, un sabotage sera envoyé au panneau de contrôle. Il est vivement recommandé d'utiliser lesvis de montage lorsque vous choisissez l'option de surveillance de sabotage mural.Remplacement de la batteriePour remplacer la batterie, ouvrez l'un des côtés du dispositif en insérant un tournevis plat et en tournant douce-ment afin de séparer le dessus et le fond en plastique (Fig A). Une fois le dispositif ouvert, la batterie est visibleRetirez la vieille batterie et installer la nouvelle batterie (voir Figure B). Observer la polarité correcte. ATTEN-TION! : La batterie pourrait exploser si elle est détériorée. Ne pas recharger,démonter ou jeter au feu.SpécificationsDimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75mmx31mmx22mm (2.9”x1.2”x0.87”)Température d’opération. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 - 49oC (32 -120oF)Humidité en opération . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5 to 93% RHFréquence d’opération . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .433MHzBatterie. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tekcell/Panasonic CR2 LithiumVie de batterie. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8 années** N’a pas été verifiée parUL/ULCCompatible avec PC5132-433, PC4164-433, NT9005-433, RF5501-433, RF5108-433Instructions d’InstallationWS4945Mini Contacto de Puerta/VentanaAlimentación de la unidad WS4945Para mayor comodidad, el WS4945 se comercializa con la batería instalada. Para activarla, sujete la unidad firme-mente con una mano y tire de la lengüeta de plástico en la dirección indicada.Ubicación del WS4945Seleccione la ubicación donde desee montar el WS4945. NOTA: Las señales de RF pueden verse afectadaspor objetos de metal, como puertas de metal o espejos grandes. Debe evitar este tipo de ubicaciones ya quepueden afectar al funcionamiento adecuado del WS4945. Registrar, programar y colocarRegistre el WS4945 programando el número de serie de 6 dígitos (ubicado en el dispositivo) en el receptor. Cuandoel WS4945 esté registrado, debe realizar una comprobación de ubicación de módulos para asegurarse de que laubicación elegida es adecuada. Consulte el manual de instalación del receptor para obtener más detalles. Montaje del WS4945 y del imánCuando haya determinado la ubicación adecuada (consulte la sección Registrar, programar y colocar), podrá mon-tar el WS4945 de forma definitiva. NOTA: Es la responsabilidad del instalador asegurarse de que elWS4945 está montado con seguridad en la localización prevista.Usar los tornillos proporcionados: Retire la parte posterior del WS4945. Monte la carcasa posterior del WS4945en la ubicación deseada mediante los tornillos suministrados.Usar la cinta adhesiva: Asegúrese de que la superficie está limpia y seca. Aplique la cinta a la parte posterior deWS4945, presione de forma continua y firme en la posición deseada durante entre unos 10 y 15 segundos. Paraque la cinta adhesiva alcance el máximo grado de efectividad deben pasar unas 24 horas.Alinee el imán con la flecha marcada   en el alojamiento del WS4945 (consulte la Figura C). Monte el imán auna distancia máxima de 1,8 cm (5/8") del WS4945 mediante la cinta o los tornillos proporcionados. Si fuera nec-esario, utilice los separadores suministrados. Cuando el WS4945 y el imán se hayan montado, abra y cierre lapuerta o ventana para garantizar que ninguna de las partes afecta al movimiento. Sólo se puede utilizar un imánpor WS4945. NOTA: La cinta adhesiva no se debe utilizar en instalaciones que cumplan la norma UL.Usar Contactos ExternosLas terminales du contacto externo pueden ser usadas para conectar contactos externos o otros interruptores/dispos-itivos al transmisor universal. Instale el dispositivo adicional de acuerdo a las instrucciones del fabricante. Conecte eldispositivo a las terminales del contacto del WS4945. La entrada es normalmente cerrada y no es supervisada.Para instalaciones, los cables que conectan el dispositivo externo a las terminales de entrada no deben exceder 16"(40cm) en longitud, siempre que la resistencia del cable no exceda 100 Ohms. El contacto y transmisor deben estaren el mismo cuarto.  Solamente un contacto puede ser usado. Si un contacto externo es usado, no instale el imán.Interruptor de sabotajeFuera de la caja, la unidad WS4945 se suministra con detección de manipulación de carcasa. Si la carcasa se quita,la unidad WS4945 informará de un sabotaje de zona al panel de control. Para proporcionar más seguridad, launidad WS4945 también se ha diseñado para proporcionar supervisión de sabotaje de la pared. Sólo es necesarioreemplazar el activador de goma corto (consulte la Figura D) por el más largo que se incluye en el paquete. Conesta opción, si la carcasa se abre o el transmisor se quita de su ubicación, se enviará una notificación de sabotaje alpanel de control. Se recomienda encarecidamente que los tornillos de montaje se empleen cuando se utilice laopción de sabotaje de la pared.Sustitución de la bateríaPara sustituir la batería, abra cualquier lado de la unidad insertando un destornillador plano y girándolo cuidadosa-mente para separar el plástico superior e inferior (Figura A). Una vez separados, podrá ver la batería. Extraiga labatería gastada y instale batería nueva (consulte la Figura B), observa la polaridad correcta.  ATTENCIÓN! :La batería puede estallar si no se trata con cuidado. No la recargue, desmonte niexponga al fuego.EspecificacionesDimensiones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75mmx31mmx22mm (2.9”x1.2”x0.87”)Temperatura para Operar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 49oC (32 to 120oF)Humedad para Operar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 93% RHFrecuencia de funcionamiento. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .433MHzBateria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tekcell/Panasonic CR2 LithiumVida de la bateria  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-8 años** No ha sido probada por UL/ULCCompatible con PC5132-433, PC4164-433, NT9005-433, RF5501-433, RF5108-433Instrucciones de Instalación
©2006 Digital Security ControlsToronto, Canada  •  www.dsc.comTechnical Support/Centre d’aide technique/Líneas Tech: 1-800-387-3630 (Canada & US) or 905-760-3036Printed in CanadaFCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use thisequipment.This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manu-facturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with thelimits for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to pro-vide reasonable protection against such interference in any residential installation. However, there is no guarantee that interferencewill not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can bedetermined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the fol-lowing measures:• Re-orient the receiving antenna• Relocate the alarm control with respect to the receiver• Move the alarm control away from the receiver• Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user mayfind the following booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”.This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4.IC: 160A-06WS4945The term ‘IC:’ before the radio certification number only signifies that Industry Canada technical specifications were met.29034668R001Tamper Switch/ Interrupteur Antisabotage/ Interruptor de SabotajeExternal Contact TerminalsBornes pour Contact ExterneTerminales para Contacto Externo+-BATTERYPILEBATERIAFigure  BNOTE:  Use only / utilisez seulement / use solamente:Panasonic CR-2 or Tekcell CR-2 Lithium Battery.Install Battery/Installez la pile/Instalarla BateríaMagnet / l'aimantimanSymbol on side of the case indicates location of reed switchLe symbole sur le côté du coffret indique l’emplacement du commutateur à lamesEl símbolo en el lateral del compartimento muestra la ubicación del conmutador de lengüeta5/8" space maximum (1.8cm)Espacement maximum de 1,8cm (5/8 pouce)Espacio máximo de 1,8 cm (5/8”)Reed switch on underside of PC Board (in unit).Commutateur à lames sur la face inférieure de la carte de circuit imprimé.Conmutador de lengüeta en la parte inferior de la placa del equipo (en la unidad)}Figure CMount Transmitter and Magnet/Fixez le transmetteur et l’aimant/Montar el Transmisor e ImánCase TamperBackplatePlaque arrièrePlaqueta posteriorCoffret de sabotageSabotaje de carcasaFigure  DChanging the Tamper/Changer le sabotage/Cambiar el sabotajeTo remove cover, insert screwdriver here and gently twist. Ouvrez l'un des côtés du dispositif en insérant un tournevis plat et en tournant doucement.Abra cualquier lado de la unidad insertando un destornillador plano y girándolo cuidadosamente.Figure  A

Navigation menu