WS900Self-Contained Wireless Security SystemV1.0 User Manual   WARNING:Thismanualcontainsinformationonlimitationsregardingproductuseandfunctionandinformationonthelimitationsastoliabilityofthemanufacturer.Readtheentiremanualcarefully.Including 3G7090 and LT7090 Cellular Alarm Communicator
Table of ContentsTable of Contents1.0AboutYourSecuritySystem 31.1FireDetection 31.2CarbonMonoxideDetection 31.3Testing 31.4Monitoring 31.5Maintenance 42.0GeneralSystemOperation 52.1IntegratedKeypad 52.2PanelIndicators 52.3ImportantNotice 92.4LanguageSelection 92.5SystemModels 93.0ArmingtheSystem 103.1StayArming 103.2SilentExitDelay 103.3AwayArming 103.4QuickExit 113.5ArmingErrorsandExitFaults 113.5.1ArmingError 113.5.2AudibleExitFault 113.6AlarmCancelWindow 113.7BypassZones 123.8BypassGroup 124.0DisarmingtheSystem 134.1DisarmingError 135.0UsingWirelessKeys 146.0EmergencyKeys 156.1Two-WayAudioOperation 156.2Intrusion(Burglary)AlarmContinuousSiren 156.3WhenAlarmSounds 166.4FireAlarmPulsedSiren(Temporal3) 166.5CarbonMonoxide(CO)Alarm 167.0ManagingUsers 177.1AccessCodeTypes 177.2Level1Access(Supervisor/Administrator) 177.3Level2Access(Basic/StandardUser) 187.4Level3Access(Maintenance/Guest) 188.0ViewingTroublesontheIntegratedKeypad 198.1AlarmMemory 209.0TestingYourSystem 219.1SystemTest 2110.0SafetyInstructions 2210.1RegularMaintenanceandTroubleshooting 2310.2CleaningandMaintenance 2311.0LocatingDetectorsandEscapePlan 2411.1SmokeDetectors 2411.2FireEscapePlanning 2511.3CarbonMonoxideDetectors 2612.0InstallerWarning 2712.0RegulatoryAgencyStatements 2813.0ReferenceSheets 3013.1SystemInformation 3013.2ServiceContactInformation 30- 2 -
Chapter 1.0 About Your Security System1.0 About Your Security SystemReadthismanualcarefullyandhaveyourinstallerinstructyouonyoursystem'soperationandonwhichfeatureshavebeenimplementedinyoursystem.Allusersofthissystemshouldbefullyinstructedinitsuse.FillouttheSystemInformationpagewithallofyourzoneinformationandaccesscodes,andstorethismanualinasafeplaceforfuturereference.Note:TheWS900securitysystemincludesspecificfalsealarmreductionfeaturesandisclassifiedinaccordancewithANSI/SIACP-01-2014ControlPanelStandard-FeaturesforFalseAlarmReduction.Consultyourinstallerforfurtherinformationregardingthefalsealarmreductionfea-turesbuiltintoyoursystem,asthismanualdoesnotcoverallfeatures.1.1 Fire DetectionThissystemcanmonitorfiredetectiondevices,suchassmokedetectors,andprovideawarningifafireconditionisdetected.Goodfiredetectiondependsonhavinganadequatenumberofdetectorsplacedinappropriatelocations.ThisequipmentmustbeinstalledinaccordancewithNFPA72(N.F.P.A.,BatterymarchPark,QuinceyMA02269).CarefullyreviewtheFamilyEscapePlanningguidelinesinthismanual.Note:Yourinstallermustenableandconfigurethisfeature.1.2 Carbon Monoxide DetectionThissystemcanmonitorcarbonmonoxidedetectorsandprovideawarningifcarbonmonoxideisdetected.ReadtheFamilyEscapePlanningguidelinesinthismanualandtheinstructionsforthecar-bonmonoxidedetector.Note:Yourinstallermustenableandconfigurethisfeature.1.3 TestingTestyoursystemweeklytoensurethatyoursystemfunctionsasintended.RefertotheTestingyourSystemsectioninthismanual.Ifyoursystemdoesnotfunctionproperly,callyourinstallationcom-panyforservice.1.4 MonitoringThissystemcantransmitalarms,troublesandemergencyinformation.Ifyouinitiateanalarmbymistake,immediatelycallthecentralstationtopreventanunnecessaryresponse.Note:lYourinstallermustenablethemonitoringfunctionbeforeitisfunctional.lConsultwithyourinstallertodetermineifyoursystemisconfiguredwithacommunicatordelay.Acommunicatordelaypreventsareporttothecentralstationifthecontrolpanelisunsetwithin30-45secondsafteranintrusionalarmistriggered.Notethatfire-typealarmsarenormallyreportedwithoutadelay.lEnsurethatyourinstallerverifiesthatyoursystemiscompatiblewiththeCentralStationReceiverformatatyearlyintervals.- 3 -
Chapter 1.0 About Your Security System1.5 MaintenanceWithnormaluse,thesystemrequiresminimummaintenance.Notethefollowingpoints:lDonotwashthesecurityequipmentwithawetcloth.Lightdustingwithaslightlymoistenedclothremovesnormalaccumulationsofdust.lReplacethestandbybatteryevery3-5years.WARNING!Donotattempttoreplacethebatteryoropentheenclosure,asthereisariskofelec-tricshockorfire.Forothersystemdevicessuchassmokedetectors,passiveinfrared,ultrasonicormicrowavemotiondetectors,orglassbreakdetectors,consultthemanufacturer’sliteraturefortestingandmain-tenanceinstructions.- 4 -
Chapter 2.0 General System Operation2.0 General System OperationYoursecuritysystemcomprisesanintegratedalarmcontrol/panelandvarioussensorsanddetectors.Thepanelismountedbythemainentry/exitlocation.Thesystemisself-contained;electronicsandstandbybatteryarehousedwithintheunit.Note:Ensurethatonlytheinstalleroraserviceprofessionalhasaccesstothesystem.Thesecuritysystemhasseveralzonesofareaprotection.Eachofthesezonescommunicatestooneormorewirelesssensors,suchasmotiondetectors,glassbreakdetectors,doorcontacts,etc.AsensorinalarmisindicatedbymessagesontheWS900mobilephoneuserapplication.AdditionalfeaturesincludeAutomaticInhibit(SwingerShutdown)foralarm,TamperandTroublesignalsafterthreeoccurrencesinagivensetperiod,andaprogrammableKeypadLockoutoption.ForSIACP-01classifiedinstallations,theswingershutdownfeatureisprogrammedsuchthatoneortwotripsshutsdownthezone.Thezoneisrestoredafteramanualresetbyenteringtheaccesscodeatthetimeofdisarmingthealarmsystem,oritisresetautomaticallyafter48hourswithnotripsonanyzones.2.1 Integrated KeypadTheWS900systemincludesacapacitivetouchintegratedkeypadwith16keys:numbers0thru9,*,#,Fire,Auxiliary,Panic(FAP),andshift(uparrow).Innormaloperation,thekeypadremainsdimwhennotinuse.Whenauserisincloseproximity,thenumberkeysilluminate.Note:TheFAPkeysdonotilluminateunlesstheshiftkeyistapped.SeetheEmergencyKeyssec-tionformoreinformation.Note:Thekeypadcanonlybeusedforarming,disarming,andthelocalFAP.Thesamefunctionsareavailablewhenswitchingbetweenpartitions.2.2 Panel IndicatorsTheWS900systemincludesaseriesofilluminatedpointsourcestatusindicators.Thereisamin-imumofsevenindicators:lFoursingle-colorLEDslThreebi-colorLEDs(redandgreen)- 5 -
Chapter 2.0 General System Operation1234 8765Item Description1 PowerLED2 ReadytoArmLED3 ArmedLED4 TroubleLED5 WiFiSignalStrengthLED6 CellularSignalStrengthLED7 RemoteConnectionLED8 MicrophonePower Status Light LED  indicator  Description ONSteady ACpoweriscurrentlyconnectedtothesystem.Flashing SystemTestAllstatusLEDsflashatthesametime.OFF Thisindicatesthefollowingconditions:lThesystemisnotpoweredON.lNOACisconnectedandthesystemisoper-atingonthebackupbattery.lNOACisconnectedandthebackupbatteryisdischarged..Ready to Arm Status Light LED  indicator  Description ONSteady Thepartitionisreadytoarm.OFF Thesystemisnotreadytoarm.Flashing SystemTestAllstatusLEDsflashatthesametime. InstallerWalkTestReady,Trouble,andArmLEDsflashatthesametime.- 6 -
Chapter 2.0 General System OperationArmed Status Light LED  indicator  Description ONSteady Thepartitionisarmed..Flashing ThesysteminAlarm.Note:SilentalarmsorpanicdonotflashtheAlarmLED.SystemTestAllstatusLEDsflashatthesametime.InstallerWalkTestReady,Trouble,andArmLEDsflashatthesametime.OFF ThepartitionisdisarmedTrouble Status Light LED  indicator  Description ONSteady Asystemtroubleispresent.Flashing[cadenceof500msOn/500msOFF][*][2]TheTroublemenuisaccessed.Flashing[cadenceof250msON/250msOFF/250msON/750msOFF]Thesystemisinthesecond-levelsubmenu.Flashing[cadenceof250msON/250msOFF/250msON/250msOFF/250msON/750msOFF]Thesystemisinthethird-levelsubmenu.Flashing SystemTestAllstatusLEDsflashatthesametime.Flashing InstallerWalkTestReady,Trouble,andArmLEDsflashatthesametime.OFF Systemtroublesarecleared.WiFi Signal Strength Status Light LED  indicator  Description ONSteady(green) Theradioisactivewithastrongsignalconnection.ONSteady(yellow) Theradioisactivewithaweaksignalconnection.ONSteady(red) Thereisnosignal.ONFlashing(red). Therewashardwarenetworkreset.Flashesredforseveralseconds,thenflashesgreenSystemTestAllstatusLEDsflashatthesametime.OFF ClientModeisOFF.- 7 -
Chapter 2.0 General System OperationCellular Signal Strength Status Light LED  indicator  Description ONSteady(green)Cellularisactivewithastrongsignalcon-nection.ONSteady(yellow)Cellularisactivewithaweaksignalcon-nection.ONSteady(red) Thereisnosignalornoconnection,butaconnectionisexpected.Flashesredforafewseconds,thenflashesgreenSystemTestAllstatusLEDsflashatthesametime.Remote Connection Status Status Light LED  indicator  Description ONSteady(green) ThelinkisactivewithTycoOnorthirdpartyserver.ONFlash(red) ThelinkactivatesbutfailstocommunicatewithTycoOnorthirdpartyserver.OFF ThelinkisnotyetactivewithTycoOnorthirdpartyserver..ONFlash(green) ThelinkisactiveTycoOnorthirdpartyserverandInstallerAccessisavailable.Flashesredforafewseconds,thenflashesgreenSystemTestAllstatusLEDsflashatthesametime.- 8 -
Chapter 2.0 General System Operation2.3 Important NoticeAsecuritysystemcannotpreventemergencies.Itisonlyintendedtoalertyouandyourcentralsta-tion,ifapplicable,toanemergencysituation.Securitysystemsaregenerallyveryreliable,buttheymaynotworkunderallconditionsandtheyarenotasubstituteforprudentsecuritypracticesorlifeandpropertyinsurance.Yoursecuritysystemmustbeinstalledandservicedbyqualifiedsecurityprofessionals.Theseprofessionalscaninstructyouonthelevelofprotectionthathasbeenprovidedandonsystemoperations.Note:WhenthepanelisinSleepMode,itissavingbatterylife.Thepanelwillnotbeturnedonuntilthereisaspecificreason,suchasahandwaveinfrontofthepanel,orthestartofanentrydelay.Inthismodethekeypadisstillfunctioningandnothingwillbevisible;howeverifdesired,yourinstallercanenablethearmedstatustobevisiblewhileinSleepMode.2.4 Language SelectionThesystemsupportsthefollowingthreelanguages:lEnglishlFrenchlSpanishYoucanselectthelanguagefromthetabletuserinterfaceortheuserapp.2.5 System ModelsThereferencetoWS900inthismanualcoversthefollowingmodels:WS900-29* Alarmsystemwithtwo-wayaudiosupport,operatingin912-919MHzbandWS900-19* Alarmsystemwithtwo-wayaudiosupport,operatingin912-919MHzband3G7090* 3GCellularAlarmCommunicatorLT7090* VerizonLTEOnlyCellularCommunicator(*)ThesedevicesareUL/ULClisted.WS900-28 Alarmsystemoperatingin868MHzbandWS901-18 Alarmsystemoperatingin868MHzbandWS901-24EU Alarmsystemoperatingin433MHzbandWS901-14 Alarmsystemoperatingin433MHzband3G7090-EU 3GCellularAlarmCommunicator- 9 -
Chapter 3.0 Arming the System3.0 Arming the SystemYoucanarmthesystemusingthefollowingoptions:lIntegratedkeypadlTabletlUserapplWirelesskey(Refertosection5.0foralistofUL/ULClistedcompatiblewirelesskeys.)3.1 Stay ArmingStayArmingarmstheperimeterofthepremiseswhilepermittingmovementinside.ToarmthesysteminStaymode,dothefollowingsteps:1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindicatorison.2. Enteravalidusercodeanddonotleavethepremises.Thesystemwillautomaticallyignorebypassedzones.Exitdelaybegins.3. Whenexitdelayisactive,theArmed andReadyindicatorsturnonandthekeypadissilent.Whentheexitdelayhasexpired,thesystemisarmedandindicatedbythefollowingconditions:lTheReadyindicatorturnsoff.lTheArmedindicatorstayson.Note:ForSIACP-01listedpanels,theStayArmingexitdelaywillbetwiceaslongastheAwayArmingexitdelay.IfyoursystemisinstalledinaccordancewithSIACP-01StandardforFalseAlarmReduction,thesecuritysystemarmsintheStayArmedmodeiftheexitdelaytimeexpiresandthereisnoexit.3.2 Silent Exit DelayIfthesystemisarmedinStaymodeorusingtheNo-Entryarmingmethod,thekeypadbuzzerissilencedandtheexittimeisdoubledforthatexitperiodonly.(SIACP-01only.)3.3 Away ArmingAwayArmingarmstheentiresystem,includingtheperimeterandinteriordevices.ToarmthesysteminAwaymode,dothefollowingsteps:1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindicatorison.2. Enteravalidusercodeandexitthepremisesthroughadoorprogrammedasentry/exittype.Exitdelaybegins.3. Whenexitdelayisactive,theArmed andReadyindicatorsturnonandthekeypadbeepsoncepersecond.Dependingonyoursystemconfiguration,youhave____secondstoexitthepremises.Yourinstallercanprogramthistime.4. Thekeypadbuzzeremitsadistinctpulsatingrateduringthelast10secondsoftheexitdelaytoindicatethatthetimeisexpiring.5. Tocancelthearmingsequence,enteryouraccesscode.- 10 -
Chapter 3.0 Arming the SystemWhentheexitdelayhasexpired,thesystemisarmedandindicatedbythefollowingconditions:lTheReadyindicatorturnsoff.lTheArmedindicatorstayson.lThekeypadissilent.Note:InAwayArmingmode,manuallybypassedzonesareloggedandcommunicatedtothecent-ralstation.IfyoursystemisinstalledinaccordancewithSIACP-01StandardforFalseAlarmReduction,thefollowingconditionapplies:Violationandrestoral,followedbyasecondviolationoftheentry/exitzonebeforetheendoftheexitdelay,restartstheexitdelay.Note:Thisfunctionisavailableonthetabletanduserapp.3.4 Quick Exit Ifthesystemisarmedandyoumustexit,usetheQuickExitfunctiontoavoiddisarmingandrearm-ingthesystem.Usingthisfunctiongivesyou2minutestoexitthepremises.Whenthedoorisclosedafterexiting,theremainingexittimeiscancelled.3.5 Arming Errors and Exit FaultsYoursecuritysystemaudiblynotifiesyouofanyerrorswhenyouareattemptingtoarmthesystemorexitthepremises.3.5.1 Arming ErrorAnerrortone(longbeep)soundsifthesystemisunabletoarm.Armingerrorsoccurunderthefol-lowingconditions:lThesystemisnotreadytoarm,i.e.sensorsareopenlTheenteredusercodeisincorrect.lApresenttroublecondition.Ensureallsensorsaresecureandthesystemisreadytoarm,thentryagain.3.5.2 Audible Exit FaultToreducefalsealarms,theAudibleExitFaultnotifiesyouofanimproperexitwhenarmingthesys-tem.Iftheentry/exitdoorisnotsecurelyclosedduringtheprogrammedexitdelay,thesystemwillsoundthealarmtoindicateanimproperexit.Note:Yourinstallermustenablethisfeature.Tocorrectandexitfault,dothefollowingsteps:1. Re-enterthepremises.2. Enteryouraccesscodetodisarmthesystembeforetheentrydelaytimerexpires3. Ensureallsensorsaresecureandthesystemisreadytoarm.4. RepeattheAwayarmingprocedure.3.6 Alarm Cancel WindowThereisaperiodoftimeinwhichyoucancancelthealarmtransmission.Whentheprogrammedalarmtransmissiondelayexpires,cancellinganalarmsendsamessagetothecentralmonitoringsta-tion.Whenthecancellationmessageissuccessfullytransmitted,thesystembeepssixtimes.Note:Yourinstallercanenableandconfigurethisfeature.- 11 -
Chapter 3.0 Arming the System3.7 Bypass ZonesUsethezonebypassingfeaturewhenyouneedaccesstoaprotectedareawhilethesystemisarmed,orwhenazoneistemporarilyoutofservice,butyouneedtoarmthesystem.Bypassedzonesarenotabletosoundanalarm.Asaresult,bypassingzonesreducesthelevelofsecurity.Ifyouarebypassingazonebecauseitisnotworking,callaservicetechnicianimmediatelytoresolvetheproblemanrestoreyoursystemtoproperworkingorder.Ensurethatnozonesareunintentionallybypassedwhenarmingyoursystem.Zonescannotbebypassedoncethesystemisarmed.Bypassedzones,exceptfor24-hourzones,areautomaticallycancelledeachtimethesystemisdisarmedandmustbebypassedagainbeforethenextarming.Note:lTwo-hourzonescanonlybeunbypassedmanually.lThisfunctionisavailableonthetabletanduserapp.lForULlistedinstallations,zonescanonlybebypassedmanually.3.8 Bypass GroupAbypassgroupisaselectionofzonesprogrammedintothesystem.Ifyoubypassagroupofzonesonaregularbasis,youcanprogramthemintoabypassgroup,sothatyoudonothavetobypasseachzoneindividually.Notethatyoucanonlyprogramonebypassgroupatatime.Note:lThisfeatureisnottobeusedinULListedinstallations.lThisfunctionisavailableonthetablet.lForULlistedinstallations,zonescanonlybebypassedmanually.- 12 -
Chapter 4.0 Disarming the System4.0 Disarming the SystemYoucanarmthesystemusingthefollowingoptions:lIntegratedkeypadlTabletlUserapplWirelesskey(Refertosection5.0foralistofUL/ULClistedcompatiblewirelesskeys.)Todisarmthesystemontheintegratedkeypad,dothefollowingsteps:1. Enteryouraccesscode.2. Ifyouopentheentry/exitdoor,acontinuoustoneindicatesthatentrydelayhasstarted.Enteryouraccesscodewithin____secondstoavoidanalarmcondition.Yourinstallercanprogramthistime.4.1 Disarming ErrorIfyourcodeisinvalid,thesystemwillnotdisarmandthesystememitsa2-seconderrortone.Ifthishappens,press[#]andtryagain.- 13 -
Chapter 5.0 Using Wireless Keys5.0 Using Wireless KeysInadditiontothekeypad,youcancontrolyoursystemwithtwo-waywirelesskeys.Allwirelesskeybuttonsareprogrammable.Yourinstallercanverifythefunctionsforeachkey.Usingatwo-waywirelesskey,youcanarmordisarmthesystemwhileyouareincloseproximitytoyourhouse,oryoucancallforhelp.ThefollowingwirelesskeysarecompatiblewiththeWS900system:PG4929/PG8929/PG9929 PG4939/PG8939/PG993967123455234161. AwayArm2. StayArm3. Disarm4. Panic5. CommandOutput16. MessageLED7. StatusLEDs1. AwayArm2. StayArm3. Disarm4. Panic5. CommandOutput16. LEDToarmthesystemwithawirelesskey,pressthedesiredarmingmodebuttonwhentheReadyindic-atorison.Note:Whenarmingthesystemwithatwo-waywirelesskey,thesystemsquawksoncetoindicatethesystemisarmed.Todisarmthesystemwithatwo-waywirelesskey,dothefollowingsteps:1. Pressthedisarmbutton.2. Ifyouwalkthroughtheentrydoor,thekeypadwillbeep.Pressthedisarmbuttonwithin____secondstoavoidanalarmcondition.Note:Whendisarmingthesystemwithatwo-waywirelesskey,thesystemsquawkstwicetoindic-atethesystemisdisarmed.- 14 -
Chapter 6.0 Emergency Keys6.0 Emergency KeysIMPORTANT:EMERGENCYUSEONLY!Theemergencykeysgenerateafire,auxiliary,orpanicalarmandalertsthecentralmonitoringsta-tion.Tousetheemergencykeys,dothefollowingsteps:1. Taptheshiftkey onthekeypad.Theemergencykeysilluminate.FireAlarmAuxiliaryAlarmPanicAlarm2. TouchtheFire,Auxiliary,orPanickeyfor2seconds,asneeded.Thesystembeepstoindicatethatthealarminputhasbeenacceptedandsenttothemonitoringstation.3. Toreturntothenumberkeypadwithoutusingtheemergencykeys,tapthe[#]key.Note:Dependingonyoursystemconfiguration,yourinstallercandisableanyoftheemergencykeys.6.1 Two-Way Audio OperationThisfeatureisusedtoverifythenatureofanalarmandtodeterminethetypeofassistancetheoccupantneeds.Whenthecentralmonitoringstationreceivesanalarm,theyinitiateatwo-wayaudiosession.Note:Onlythecentralmonitoringstationcaninitiateatwo-wayaudiosessionwhentheyreceiveanalarm.;theusercannotinitiateasession.6.2 Intrusion (Burglary) Alarm Continuous Siren!Ifyouareunsureofthesourceofthealarm,proceedwithcaution!Ifthealarmwasaccidental,enteryouraccesscodetosilencethealarm.Ifthealarmsystemisdis-armedwithintheprogrammedtransmitterdelaytime,noalarmtransmissionissenttothecentral- 15 -
Chapter 6.0 Emergency Keysmonitoringstation.Checkwithyourinstallertoseeifthisoptionhasbeenenabledonyoursystemandforthetransmitterdelaytime.Followingthetransmitterdelaytime,youhave5minutestoenteryourusercodetocancelanalarmthathasbeenpreviouslytransmitted.Acancelsignalissenttothecentralmonitoringstationandthesystemindicatesthatthecancelsignalwastransmitted.Callyourcentralmonitoringstationtoavoidadispatch.6.3 When Alarm SoundsThesystemcangeneratethethreedifferentalarmsoundsinthisorderofpriority:1. FireAlarm=Temporal/pulsedsiren2. CarbonMonoxideAlarm=fourbeeps,5-secondpause,fourbeeps3. Intrusion(Burglary)Alarm=ContinuoussirenNote:TheAuxiliaryAlarmissilentandonlyresultsinanalarmtransmissiontothecentralmon-itoringstation.6.4 Fire Alarm Pulsed Siren (Temporal 3)!Intheeventofafirealarm,followyouremergencyevacuationplanimmediately!Thefirealarmtemporal/pulsedsirensoundsofthreeshortpulsesfollowedbya1.5-secondpause,thenrepeats..Ifthefirealarmwasaccidental,e.g.burnttoast,bathroomsteam,etc.,enteryouraccesscodetosilencethealarmandcallyourcentralmonitoringstationtoavoidadispatch.Note:Verifywithyouralarmcompanythatyoursystemisequippedwithfiredetection.ForinformationonresettingsmokedetectorsseeResettingSmokeDetectors.6.5 Carbon Monoxide (CO) AlarmWARNING!CarefullyreviewyourCarbonMonoxideAlarmInstallation/UserGuidetodeterminethenecessaryactionsrequiredtoensureyoursafetyandensurethattheequipmentisoperatingcor-rectly.Incorporatethestepsoutlinedintheguideintoyourevacuationplan.!ActivationofyourCOalarmindicatesthepresenceofcarbonmonoxide(CO),whichcanbefatal.Analarmisindicatedbythefollowingconditions:lTheredLEDontheCOdetectorflashesrapidlyandbuzzersoundswitharepeatingcadenceof4quickbeeps,5-secondpause,4quickbeeps.lThesirenconnectedtothecontrolpanelproducesthesamecadenceasabove.lThesystemprovidesaudibleandvisualindicationoftheCOalarm.IftheCOalarmsounds,dothefollowingsteps:1. PressthebuttonontheCOdetectortosilencethealarm.2. Callemergencyservicesoryourfiredepartment.3. Immediatelymoveoutdoorsortoanopendoor/window.- 16 -
Chapter 7.0 Managing Users7.0 Managing UsersTheWS900systemsupportsupto100users,includingtheMasteruser.Bydefault,user#1istheMasteruser.Youcannotdisableordeletethisuserfromthesystem.Thesystemalsosupportsanadditionaltwoduresscodes,oneforeachpartition.Fromtheuserapp,youcanprogramandconfigureattributesforusers2thru100.Youcanassignausertooneorbothpartitionsandenableordisablesysteminteraction.Usercodesare4-digitsandmustbeunique;thesystemdoesnotrecognizeduplicatecodes.Ifyouprogramaduplicatecode,thesystemerrorsandthecodeisrejected.Ifyoutrytochangeanexist-ingusercodetoaonethatisalreadyprogrammed,thesystemerrorsandthecodeisunchanged.7.1 Access Code TypesTheWS900systemprovidesthefollowinguseraccesscodetypes:Master Code Thisisthesystemmastercode.Youcannotdisableordeletethiscode,butyoucanchangeitintheuserapp.Usethiscodetoprogramallotheraccesscodes,includingtheduresscodes.Youcanusethiscodetodoalluser-levelfunctions,excepttoaccessInstallermode.User Codes Therearethreeaccesslevelsforusercodes:lLevel1-Supervisor/AdministratorlLevel2-Basic/StandardUserlLevel3-Maintenance/GuestEachlevelhasdifferentpermissions.SeeUserCodeAccessLevelsfordescrip-tionsofeachlevel.Duress CodesUseduresscodestodisarmthesystemonlyinanemergencysituation.Whenused,anemergencydisarmeventtransmitstothecentralmonitoringstation.Thesystemsupportstwoduresscodes,oneforeachpartition.Thesecodesareexcludedfromthetotalnumberofavailablecodes.TheyhavetheaccesslevelofaLevel2BasicUser.7.2 Level 1 Access (Supervisor/Administrator)Usersatthislevelhavesimilarprivilegestothemasteruserbutarelimitedbasedontheirpartitionassignment.Userscandothefollowingactionsontheirpartitions:lArm/disarmlBypass/unbypasslChimeenable/disablelViewtroubleslViewalarmmemoryLevel1userscanalsodoanyuserlevelfunctionalityonthekeypadoruserapp,asfollows:lInitiatesystemtestlEnableinstallerorremoteaccesslLanguageselectionlVieweventbufferlViewimageslProgramzoneandpartitionlabelslScheduleAutoArming- 17 -
Chapter 7.0 Managing UserslInitiatefirmwareupdateslUpdatethesystemWiFiSSIDandpasswordlCreatenewusersanduserlabelslProgramduresscodesNote:Userscanonlyadd,edit,ordeleteusersthatareassignedtothesamepartitionastheyare.7.3 Level 2 Access (Basic/Standard User)Usersatthislevelhaveaccesstobasicsecurityfunctionsbutarelimitedbasedontheirpartitionassignment.Userscandothefollowingactionsontheirpartitions:lArm/disarmlBypass/unbypasslChimeenable/disablelViewsystemtroubleslViewalarmmemory7.4 Level 3 Access (Maintenance/Guest)Usersatthislevelarelimitedtoreducedsystemaccessontheirpartitionassignment.Userscandothefollowingactionsontheirpartitions:lArm/disarmlChimeenable/disablelViewsystemtroubleslViewalarmmemory- 18 -
Chapter 8.0 Viewing Troubles on the Integrated Keypad8.0 Viewing Troubles on the Integrated KeypadWhenthesystemdetectsatroublecondition,theTrouble indicatorturnsonandthesystembeepsonceevery10seconds.Tapthe[*]keytosilencethebeeps.Note:ForULListedinstallations,youraccesscodeisrequiredtoviewsystemtroubles.Toviewtroublesontheintegratedkeypad,dothefollowingsteps:1. Whenthekeypadilluminates,tap[*][2].2. Enteryouraccesscode,ifrequired.TheTroubleindicatorflashesifanaccesscodeisrequired.Thesystemindicatestop-leveltroublecodesbyilluminatingthecorrespondingnumbersonthekeypad,andtheTroubleindicatorflashesoncewithapause,thenrepeats.3. Taponeofthenumberstoseethenextlevelcode.Atthesecondlevel,theTroubleindic-atorflashestwicewithapause,thenrepeats.4. Repeatstep3togotothenextlevel.Thesystembeepsifthereisnothird-leveltroublecondition.Atthislevel,theTroubleindicatorflashesthreetimeswithapause,thenrepeats.Ifthereismorethanonezoneintrouble,eachzonenumberwillflashinsequenceuntilyouexitthetroublemenuorwhenthetimeexpires.Atthislevel,theTroubleindicatorflashesthreetimeswithapause,thenrepeats.5. Tap[#]toreturntothepreviousleveltroublecodeortoexitthetroublemenu.Top LevelDevice TypeSecond LevelTrouble TypeThird LevelDevice ID01 SystemTrouble 01 AC Notapplicable02 BatteryTrouble03 Tamper04 RFJam02 Zone 01 AC 1-12802 BatteryTrouble03 Tamper04 Fault(supervision)05 NotNetworked06 Fire/COTrouble03 Siren 01 AC 1to1602 BatteryTrouble03 Tamper04 Fault(supervision)05 NotNetworked04 Keypad 01 AC 1to402 BatteryTrouble03 Tamper04 Fault(supervision)05 NotNetworked- 19 -
Chapter 8.0 Viewing Troubles on the Integrated KeypadTop LevelDevice TypeSecond LevelTrouble TypeThird LevelDevice ID05 Repeater 01 AC 1to802 BatteryTrouble03 Tamper04 Fault(supervision)05 NotNetworked06 Wirelesskey 01 AC 1to3202 BatteryTrouble03 Tamper04 Fault(supervision)05 NotNetworked07 Communication 01 Receivernotavailable Notapplicable02 FTC03 Receiversupervisiontrouble04 CellularTrouble05 Ethernet/WiFiTrouble06 Remoteshutdown8.1 Alarm MemoryWhenanalarmoccurswhilethesystemisarmed,itisstoredinthealarmmemorywhenyoudisarmthesystem.Thesystemsoundsadifferenttonethannormalduringentrydelay.Afterdisarmingthesystem,thezonenumberonthekeypadflashesfor5minutestoindicateanalarminmemory.Note:Ifdisarmingthesystemwitha2-waywirelesskey,thesystemsquawksthreetimestoindic-ateanalarminmemory.!Proceedwithcaution,asanintrudercanstillbewithinthepremises.Toarmthesystemagain,waveyourhandinfrontofthekeypad.Thezonenumbersstopflashingandyoucanthenarmthesystem.Thealarmmemoryclearsthenexttimeyouarmanddisarmthesystem.- 20 -
Chapter 9.0 Testing Your System9.0 Testing Your SystemInformyourMonitoringStationwhenyoubeginandendsystemtesting.Householdfirealarmsystemsshallbetestedbyaqualifiedservicetechnicianatleastevery3yearsinaccordancewithNFPA72.Itistheuser’sresponsibilitytotestthesystemweekly(excludingsmokedetectors).Ensureyoufollowallthestepsidentifiedinthefollowingsections.Shouldthesystemfailtofunctionproperly,callyourinstallerimmediatelyforservice.9.1 System TestThesystemtestactivatesa4-secondcheckofthesystemstatusindicators,keypadlights,buzzer,andsiren.Itisapartition-basedtestmustbedonewhenthesystemisdisarmed.Tostartasystemtest,dothefollowingsteps:Thefollowingconditionsindicateasystemtestisinprogress:lAllsystemstatusindicatorlightsflashfor4seconds.lAsystemtesttransmitstothecentralmonitoringstationlThesystemchecksthebackupbatterylevel.lThekeypadlightsilluminatefor4seconds.lThesystembuzzersoundsfor4seconds,orthepartitionbuzzerandsirensoundfor2secondseachinseries.- 21 -
Chapter 10.0 Safety Instructions10.0 Safety InstructionsThisequipmentisstationary-DIRECTPLUG-INandmustbeinstalledbyServicePersonsonly(ServicePersonisdefinedasapersonhavingtheappropriatetechnicaltrainingandexperiencenecessarytobeawareofhazardstowhichthatpersonmaybeexposedinperformingataskandofmeasurestominimizetheriskstothatpersonorotherpersons).Itmustbeinstalledandusedwithinanenvironmentthatprovidesthepollutiondegreemax2,overvoltagescategoryII,innon-haz-ardous,indoorlocationsonly.WARNING!Thisequipmenthasnomainson/offswitch;iftheequipmentmustbequicklydis-connected,theplugofthedirectplug-inpowersupplyisintendedtoserveasthedisconnectingdevice;itisimperativethataccesstothemainsplugandassociatedmainssocket/outlet,isneverobstructed.Whenusingequipmentconnectedtothemainsand/ortothetelecommunicationnetwork,therearebasicsafetyinstructionsthatshallalwaysbefollowed.Refertothesafetyinstructionsprovidedwiththisproductandsavethemforfuturereference.Toreducetheriskoffire,electricshockand/orinjury,observethefollowing:lDonotattempttoservicethisproductyourself.Openingorremovingthecovermayexposeyoutodangerousvoltageorotherrisk.Referservicingtoservicepersons.Neveropenthedeviceyourself.lUseauthorizedaccessoriesonlywiththisequipment!DONOTleaveand/ordepositANYobjectonthetopofthecabinetofthisequipment!Thecabinetasitisinstalledonthewall,isnotdesignedtosupportanysupplementaryweight!lDonottouchtheequipmentanditsconnectedcablesduringanelectricalstorm;theremaybeariskofelectricshock.lNevertouchun-insulatedwiresorterminalsunlesstheequipmenthasbeendisconnectedfromthemainssupplyandfromthetelecommunicationnetwork!lEnsurethatcablesarepositionedsothataccidentscannotoccur.Connectedcablesmustnotbesubjecttoexcessivemechanicalstrain.Donotspillanytypeofliquidontheequip-ment.lDonotusetheAlarmsystemtoreportagasleakifthesystemisnearaleak.Thesesafetyinstructionsshouldnotpreventyoufromcontactingthedistributorand/ortheman-ufacturertoobtainanyfurtherclarificationand/oranswerstoyourconcerns.- 22 -
Chapter 10.0 Safety Instructions10.1 Regular Maintenance and TroubleshootingKeepyourAlarmControllerinoptimalconditionbyfollowingalltheinstructionsthatareincludedwithinthismanualand/ormarkedontheproduct.Itistheend-userand/orinstaller’sresponsibilitytoensurethatthedisposaloftheusedbatteriesismadeaccordingtothewasterecoveryandrecyc-lingregulationsapplicabletotheintendedmarket.10.2 Cleaning and MaintenancelCleantheunitsbywipingwithadampclothonly.lDonotwipethefrontcoverwithalcohol.lDonotuseanywateroranyotherliquid.lDonotuseabrasives,thinners,solventsoraerosolcleaners(spraypolish)thatmayenterthroughholesintheAlarmControllerandcausedamage.lUsethesystemtestdescribedin“TestingYourSystem”tocheckthebatterycondition.Werecommend,however,thatthestandbybatteriesbereplacedevery3-5years.lForothersystemdevicessuchassmokedetectors,passiveinfrared,ultrasonicormicrowavemotiondetectorsorglassbreakdetectors,consultthemanufacturer’sliteraturefortestingandmaintenanceinstructions.- 23 -
Chapter 11.0 Locating Detectors and Escape Plan11.0 Locating Detectors and Escape PlanThefollowinginformationisforgeneralguidanceonlyanditisrecommendedthatlocalfirecodesandregulationsbeconsultedwhenlocatingandinstallingsmokeandCOalarms.11.1 Smoke DetectorsResearchhasshownthatallhostilefiresinhomesgeneratesmoketoagreaterorlesserextent.Experimentswithtypicalfiresinhomesindicatethatdetectablequantitiesofsmokeprecededetect-ablelevelsofheatinmostcases.Forthesereasons,smokealarmsshouldbeinstalledoutsideofeachsleepingareaandoneachstoreyofthehome.Thefollowinginformationisforgeneralguidanceonlyanditisrecommendedthatlocalfirecodesandregulationsbeconsultedwhenlocatingandinstallingsmokealarms.Itisrecommendedthatadditionalsmokealarmsbeyondthoserequiredforminimumprotectionbeinstalled.Additionalareasthatshouldbeprotectedinclude:thebasement;bedrooms,especiallywheresmokerssleep;diningrooms;furnaceandutilityrooms;andanyhallwaysnotprotectedbytherequiredunits.Onsmoothceilings,detectorsmaybespaced9.1m(30feet)apartasaguide.Otherspacingmayberequireddependingonceilingheight,airmovement,thepresenceofjoists,uninsulatedceilings,etc.ConsultNationalFireAlarmCodeNFPA72,CAN/ULC-S553-02orotherappropriatenationalstandardsforinstallationrecommendations.lDonotlocatesmokedetectorsatthetopofpeakedorgabledceilings;thedeadairspaceintheselocationsmaypreventtheunitfromdetectingsmoke.lAvoidareaswithturbulentairflow,suchasneardoors,fansorwindows.Rapidairmove-mentaroundthedetectormaypreventsmokefromenteringtheunit.lDonotlocatedetectorsinareasofhighhumidity.lDonotlocatedetectorsinareaswherethetemperaturerisesabove38ºC(100ºF)orfallsbelow5ºC(41ºF).lSmokedetectorsmustalwaysbeinstalledinUSAinaccordancewithChapter29ofNFPA72,theNationalFireAlarmCode:29.5.1.1.Whererequiredbyapplicablelaws,codes,orstandardsforaspecifictypeofoccupancy,approvedsingle-andmultiple-stationsmokealarmsshallbeinstalledasfollows:1. Inallsleepingroomsandguestrooms.2. Outsideofeachseparatedwellingunitsleepingarea,within6.4m(21ft)ofanydoortoasleepingroom,thedistancemeasuredalongapathoftravel.3. Oneverylevelofadwellingunit,includingbasements.4. Oneverylevelofaresidentialboardandcareoccupancy(smallfacility),includingbasementsandexcludingcrawlspacesandunfinishedattics.5. Inthelivingarea(s)ofaguestsuite.6. Inthelivingarea(s)ofaresidentialboardandcareoccupancy(smallfacility).Figure1Figure2 Figure3- 24 -
Chapter 11.0 Locating Detectors and Escape PlanFigure3aFigure411.2 Fire Escape Planning Thereisoftenverylittletimebetweenthedetectionofafireandthetimeitbecomesdeadly.Itisthusveryimportantthatafamilyescapeplanbedevelopedandrehearsed.1. Everyfamilymembershouldparticipateindevelopingtheescapeplan.2. Studythepossibleescaperoutesfromeachlocationwithinthehouse.Sincemanyfiresoccuratnight,specialattentionshouldbegiventotheescaperoutesfromsleepingquarters.3. Escapefromabedroommustbepossiblewithoutopeningtheinteriordoor.Considerthefollowingwhenmakingyourescapeplans:lMakesurethatallborderdoorsandwindowsareeasilyopened.Ensurethattheyarenotpaintedshut,andthattheirlockingmechanismsoperatesmoothly.lIfopeningorusingtheexitistoodifficultforchildren,theelderlyorhandicapped,plansforrescueshouldbedeveloped.Thisincludesmakingsurethatthosewhoaretoperformtherescuecanpromptlyhearthefirewarningsignal.lIftheexitisabovethegroundlevel,anapprovedfireladderorropeshouldbeprovidedaswellastraininginitsuse.lExitsonthegroundlevelshouldbekeptclear.Besuretoremovesnowfromexteriorpatiodoorsinwinter;outdoorfurnitureorequipmentshouldnotblockexits.lEachpersonshouldknowthepredeterminedassemblypointwhereeveryonecanbeaccoun-tedfor(e.g.,acrossthestreetorataneighbor'shouse).Onceeveryoneisoutofthebuild-ing,callthefiredepartment.lAgoodplanemphasizesquickescape.Donotinvestigateorattempttofightthefire,anddonotgatherbelongingsasthiscanwastevaluabletime.Onceoutside,donotre-enterthehouse.Waitforthefiredepartment.lWritethefireescapeplandownandrehearseitfrequentlysothatshouldanemergencyarise,everyonewillknowwhattodo.Revisetheplanasconditionschange,suchasthenumberofpeopleinthehome,oriftherearechangestothebuilding’sconstruction.lMakesureyourfirewarningsystemisoperationalbyconductingweeklytests.Ifyouareunsureaboutsystemoperation,contactyourinstaller.Werecommendthatyoucontactyourlocalfiredepartmentandrequestfurtherinformationonfiresafetyandescapeplanning.Ifavailable,haveyourlocalfirepreventionofficerconductanin-housefiresafetyinspection.- 25 -
Chapter 11.0 Locating Detectors and Escape PlanFigure511.3 Carbon Monoxide DetectorsCarbonmonoxideiscolorless,odorless,tasteless,andverytoxic,italsomovesfreelyintheair.COdetectorscanmeasuretheconcentrationandsoundaloudalarmbeforeapotentiallyharmfullevelisreached.ThehumanbodyismostvulnerabletotheeffectsofCOgasduringsleepinghours;there-fore,COdetectorsshouldbelocatedinorasnearaspossibletosleepingareasofthehome.Formaximumprotection,aCOalarmshouldbelocatedoutsideprimarysleepingareasoroneachlevelofyourhome.Figure5indicatesthesuggestedlocationsinthehome.DoNOTplacetheCOalarminthefollowingareas:lWherethetemperaturemaydropbelow-10ºCorexceed40ºClNearpaintthinnerfumeslWithin5feet(1.5m)ofopenflameappliancessuchasfurnaces,stovesandfireplaceslInexhauststreamsfromgasengines,vents,fluesorchimneyslDonotplaceincloseproximitytoanautomobileexhaustpipe;thiswilldamagethedetectorPLEASEREFERTOTHECODETECTORINSTALLATIONANDOPERATINGINSTRUCTIONSHEETFORSAFETYINSTRUCTIONSANDEMERGENCYINFORMATION.- 26 -
Chapter12.0 Installer Warning12.0 Installer WarningWarningPleaseReadCarefullyNoteToInstallers:Thiswarningcontainsvitalinformation.Astheonlyindividualincontactwithsystemusers,itisyourresponsibilitytobringeachiteminthiswarningtotheattentionoftheusersofthissystem.SystemFailuresThissystemhasbeencarefullydesignedtobeaseffectiveaspossible.Therearecircumstances,however,involvingfire,burglary,orothertypesofemer-gencieswhereitmaynotprovideprotection.Anyalarmsystemofanytypemaybecompromiseddeliberatelyormayfailtooperateasexpectedforavarietyofreasons.Somebutnotallofthesereasonsmaybe:InadequateInstallationAsecuritysystemmustbeinstalledproperlyinordertoprovideadequatepro-tection.Everyinstallationshouldbeevaluatedbyasecurityprofessionaltoensurethatallaccesspointsandareasarecovered.Locksandlatchesonwin-dowsanddoorsmustbesecureandoperateasintended.Windows,doors,walls,ceilingsandotherbuildingmaterialsmustbeofsufficientstrengthandconstructiontoprovidethelevelofprotectionexpected.Areevaluationmustbedoneduringandafteranyconstructionactivity.Anevaluationbythefireand/orpolicedepartmentishighlyrecommendedifthisserviceisavailable.CriminalKnowledgeThissystemcontainssecurityfeatureswhichwereknowntobeeffectiveatthetimeofmanufacture.Itispossibleforpersonswithcriminalintenttodeveloptechniqueswhichreducetheeffectivenessofthesefeatures.Itisimportantthatasecuritysystembereviewedperiodicallytoensurethatitsfeaturesremaineffectiveandthatitbeupdatedorreplacedifitisfoundthatitdoesnotprovidetheprotectionexpected.AccessbyIntrudersIntrudersmayenterthroughanunprotectedaccesspoint,circumventasensingdevice,evadedetectionbymovingthroughanareaofinsufficientcoverage,dis-connectawarningdevice,orinterferewithorpreventtheproperoperationofthesystem.PowerFailureControlunits,intrusiondetectors,smokedetectorsandmanyothersecuritydevicesrequireanadequatepowersupplyforproperoperation.Ifadeviceoper-atesfrombatteries,itispossibleforthebatteriestofail.Evenifthebatterieshavenotfailed,theymustbecharged,ingoodconditionandinstalledcorrectly.IfadeviceoperatesonlybyACpower,anyinterruption,howeverbrief,willrenderthatdeviceinoperativewhileitdoesnothavepower.Powerinterruptionsofanylengthareoftenaccompaniedbyvoltagefluctuationswhichmaydamageelectronicequipmentsuchasasecuritysystem.Afterapowerinterruptionhasoccurred,immediatelyconductacompletesystemtesttoensurethatthesys-temoperatesasintended.FailureofReplaceableBatteriesThissystem’swirelesstransmittershavebeendesignedtoprovideseveralyearsofbatterylifeundernormalconditions.Theexpectedbatterylifeisafunc-tionofthedeviceenvironment,usageandtype.Ambientconditionssuchashighhumidity,highorlowtemperatures,orlargetemperaturefluctuationsmayreducetheexpectedbatterylife.Whileeachtransmittingdevicehasalowbat-terymonitorwhichidentifieswhenthebatteriesneedtobereplaced,thismon-itormayfailtooperateasexpected.Regulartestingandmaintenancewillkeepthesystemingoodoperatingcondition.CompromiseofRadioFrequency(Wireless)DevicesSignalsmaynotreachthereceiverunderallcircumstanceswhichcouldincludemetalobjectsplacedonorneartheradiopathordeliberatejammingorotherinadvertentradiosignalinterference.SystemUsersAusermaynotbeabletooperateapanicoremergencyswitchpossiblyduetopermanentortemporaryphysicaldisability,inabilitytoreachthedeviceintime,orunfamiliaritywiththecorrectoperation.Itisimportantthatallsystemusersbetrainedinthecorrectoperationofthealarmsystemandthattheyknowhowtorespondwhenthesystemindicatesanalarm.SmokeDetectorsSmokedetectorsthatareapartofthissystemmaynotproperlyalertoccupantsofafireforanumberofreasons,someofwhichfollow.Thesmokedetectorsmayhavebeenimproperlyinstalledorpositioned.Smokemaynotbeabletoreachthesmokedetectors,suchaswhenthefireisinachimney,wallsorroofs,orontheothersideofcloseddoors.Smokedetectorsmaynotdetectsmokefromfiresonanotherleveloftheresidenceorbuilding.Everyfireisdifferentintheamountofsmokeproducedandtherateofburning.Smokedetectorscannotsensealltypesoffiresequallywell.Smokedetectorsmaynotprovidetimelywarningoffirescausedbycarelessnessorsafetyhaz-ardssuchassmokinginbed,violentexplosions,escapinggas,improperstorageofflammablematerials,overloadedelectricalcircuits,childrenplayingwithmatchesorarson.Evenifthesmokedetectoroperatesasintended,theremaybecircumstanceswhenthereisinsufficientwarningtoallowalloccupantstoescapeintimetoavoidinjuryordeath.MotionDetectorsMotiondetectorscanonlydetectmotionwithinthedesignatedareasasshownintheirrespectiveinstallationinstructions.Theycannotdiscriminatebetweenintrudersandintendedoccupants.Motiondetectorsdonotprovidevolumetricareaprotection.Theyhavemultiplebeamsofdetectionandmotioncanonlybedetectedinunobstructedareascoveredbythesebeams.Theycannotdetectmotionwhichoccursbehindwalls,ceilings,floor,closeddoors,glasspar-titions,glassdoorsorwindows.Anytypeoftamperingwhetherintentionalorunintentionalsuchasmasking,painting,orsprayingofanymaterialonthelenses,mirrors,windowsoranyotherpartofthedetectionsystemwillimpairitsproperoperation.Passiveinfraredmotiondetectorsoperatebysensingchangesintemperature.Howevertheireffectivenesscanbereducedwhentheambienttemperaturerisesnearorabovebodytemperatureorifthereareintentionalorunintentionalsourcesofheatinornearthedetectionarea.Someoftheseheatsourcescouldbeheaters,radiators,stoves,barbeques,fireplaces,sunlight,steamvents,light-ingandsoon.WarningDevicesWarningdevicessuchassirens,bells,horns,orstrobesmaynotwarnpeopleorwakensomeonesleepingifthereisaninterveningwallordoor.Ifwarningdevicesarelocatedonadifferentleveloftheresidenceorpremise,thenitislesslikelythattheoccupantswillbealertedorawakened.Audiblewarningdevicesmaybeinterferedwithbyothernoisesourcessuchasstereos,radios,televisions,airconditionersorotherappliances,orpassingtraffic.Audiblewarningdevices,howeverloud,maynotbeheardbyahearing-impairedperson.TelephoneLinesIftelephonelinesareusedtotransmitalarms,theymaybeoutofserviceorbusyforcertainperiodsoftime.Alsoanintrudermaycutthetelephonelineordefeatitsoperationbymoresophisticatedmeanswhichmaybedifficulttodetect.InsufficientTimeTheremaybecircumstanceswhenthesystemwilloperateasintended,yettheoccupantswillnotbeprotectedfromtheemergencyduetotheirinabilitytorespondtothewarningsinatimelymanner.Ifthesystemismonitored,theresponsemaynotoccurintimetoprotecttheoccupantsortheirbelongings.ComponentFailureAlthougheveryefforthasbeenmadetomakethissystemasreliableaspos-sible,thesystemmayfailtofunctionasintendedduetothefailureofacom-ponent.InadequateTestingMostproblemsthatwouldpreventanalarmsystemfromoperatingasintendedcanbefoundbyregulartestingandmaintenance.Thecompletesystemshouldbetestedweeklyandimmediatelyafterabreak-in,anattemptedbreak-in,afire,astorm,anearthquake,anaccident,oranykindofconstructionactivityinsideoroutsidethepremises.Thetestingshouldincludeallsensingdevices,keypads,consoles,alarmindicatingdevicesandanyotheroperationaldevicesthatarepartofthesystem.SecurityandInsuranceRegardlessofitscapabilities,analarmsystemisnotasubstituteforpropertyorlifeinsurance.Analarmsystemalsoisnotasubstituteforpropertyowners,renters,orotheroccupantstoactprudentlytopreventorminimizetheharmfuleffectsofanemergencysituation.- 27 -
Chapter 12.0 Regulatory Agency Statements12.0 Regulatory Agency StatementsFCCMODIFICATIONSTATEMENTDigital Security Controlshasnotapproved anychangesor modificationsto thisdevicebythe user.Anychanges ormodifications couldvoidthe user’sauthoritytooper-ate theequipment.DigitalSecurityControlsn’approuve aucunemodification apportée àl’appareil parl’utilisateur,quelle qu’en soitlanature. Toutchangement oumodificationpeuventannuler ledroitd’utilisationdel’appareilparl’utilisateur.ISEDCANADAINTERFERENCESTATEMENTThisdevicecomplies withPart15 oftheFCCRules andISEDCanada licence-exemptRSS standard(s).Operationissubject tothefollowingtwoconditions: (1)thisdevice may notcauseinterference, and (2)thisdevicemust accept any interference,includinginterferencethatmay cause undesiredoperationofthe device.Le présentappareilestconformeaux CNRd'ISEDCanada applicablesaux appareilsradioexemptsdelicence. L'exploitationest autorisée aux deuxconditionssuivantes:(1)l'appareilnedoit pasproduiredebrouillage, et(2)l'utilisateurdel'appareildoitacceptertoutbrouillageradioélectrique subi, êmesi le brouillage estsusceptible d'en compromettrele fonctionnement.FCCCLASSBDIGITALDEVICENOTICEThisequipmenthasbeen tested and foundtocomply with the limitsforaClass Bdigital device,pursuant topart15 oftheFCCRules.These limitsare designed toprovide reasonable protection against harmful interference in aresidentialinstallation.Thisequipment generatesusesandcan radiate radio frequency energyand, ifnotinstalled andused in accordance with the instructions,may cause harmful interference to radiocommunications.However,thereisnoguaranteethatinterferencewill notoccurin a particular installation. Ifthisequipmentdoescause harmful interference to radioortelevisionreception, whichcanbe determinedby turning theequipment offandon,theuser isencouragedtotry to correct theinterference byoneor more ofthefollowing measures:-Reorientthereceivingantenna.-Increasetheseparationbetween the equipment and receiver.-Connecttheequipmentinto an outlet onacircuitdifferentfrom that towhichthereceiverisconnected.-Consultthe dealer orexperienced radio/televisiontechnicianfor help.CANICES-3(B) /NMB-3(B)ThisClassB digitalapparatuscomplieswithCanadianICES-003.Cetappareilnumériquedeclasse Bestconformeà la norme canadienne ICES-003.The reference totheWS900-xxthroughout this manual isapplicabletothefollowing model numbers: WS900-19andWS900-29.FCCID:F5316WS90019FCCID:F5316WS900-29IC:160A-WS90019IC:160A-WS90029FCC/ISEDCANADAWIRELESSNOTICEThisequipmentcomplieswithFCCandISEDCanada radiation exposure limitssetforthfor anuncontrolled environment.The antenna should beinstalledandoperatedwithminimum distance of20 mbetweenthe radiator and yourbody.Antenna gainmustbe below:Frequencyband 3G4000GSM850/FDDV 2.1dBiPCS1900/FDDII 3.7dBiLTEB4(1700MHz) 1.5dBiLTEB13(700MHz) 2.2dBiThe antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except as described in this user manual.Cet appareil estconformeaux limitesd'exposition aux rayonnementsdelaIC pourun environnementoncontrôlé. L'antenne doit êtreinstallédefaçon à garderunedistance minimalede 20centimètres entrelasource de rayonnementsetvotrecorps.Gainde l'antennedoit être ci-dessous:Frequencyband 3G4000GSM850/FDDV 2.1dBiPCS1900/FDDII 3.7dBiLTEB4(1700MHz) 1.5dBiLTEB13(700MHz) 2.2dBiThe reference totheCellularCommunicatorxx7090throughout thismanualisapplicabletothe following model numbers: 3G7090andLT7090.FCCID:F53163G7090FCCID:F5316LT7090IC:160A-3G7090IC:160A-LT7090WARNING:TosatisfyFCCRFexposurerequirementsformobiletransmittingdevices,aseparationdis-tanceof20cmormoremustbemaintainedbetweentheantennaofthisdeviceandpersonsduringdeviceoperation.FCC/ICLABELThe modulartransmitter 3G7090or LT7090 is labeled withitsownFCCIDandICnumber.Whenthe module isinstalledinsidethehost device WS900-19 orWS900-29andtheFCCID/ICof the module isnotvisible,thehost device displays theprovidedlabelreferringto the FCCIDandICof the enclosed module.Thislabel isshipped together withthemoduleand it istheresponsibilityof the integrator to applyittothe exterior oftheenclosure, as displayedinthefollowing figure.Label Placement- 28 -L'antenne (s) utilisée pour cet émetteur ne doit pas être situé ou opérant en conjonction avec une autre antenne ou émetteur, sauf tel que décrit dans ce mode d'emploi.Le modulaire émetteur 3G7090 ou LT7090 est étiqueté avec son propre ID FCC et le numéro IC. Lorsque le module est installé à l'intérieur du dispositif hôte WS900-19 ou WS900-29 et la FCC ID / IC du module ne soit pas visible, le dispositif d'accueil affiche l'étiquette fournie se référant à l'ID FCC et IC du module ci-joint. Ce label est livré avec le module et il est de la responsabilité de l'intégrateur de l'appliquer à l'extérieur de l'enceinte, comme indiqué dans la figure suivante.Model 3G7090 Contains FCC ID: F53163G7090Contains IC: 160A-3G7090 Model LT7090 Contains FCC ID: F5316LT7090Contains IC: 160A-LT7090
Chapter 12.0 Regulatory Agency Statements+HUHE\ '6& GHFODUHV WKDW WKLV GHYLFH LV LQ FRPSOLDQFH ZLWK WKH HVVHQWLDOUHTXLUHPHQWVDQGRWKHUUHOHYDQWSURYLVLRQVRI'LUHFWLYH(&7KH FRPSOHWH 577( 'HFODUDWLRQ RI &RQIRUPLW\ FDQ EH IRXQG DWKWWSZZZGVFFRPOLVWLQJVBLQGH[DVS[&=( '6& MDNR Y¿UREFH SURKODģXMH ŀH WHQWR Y¿UREHN MH Y VRXODGX VH YģHPLUHOHYDQWQ¯PLSRŀDGDYN\VPÝUQLFH(&'$1'6&HUNO¨UHUKHUYHGDWGHQQHNRPSRQHQWHQRYHUKROGHUDOOHYLNWLJHNUDYVDPWDQGUHEHVWHPPHOVHUJLWWLGLUHNWLY(&'87+LHUELMYHUNODDUW'6& GDWGLWWRHVWHOLQRYHUHHQVWHPPLQJLVPHW GHHLVHQHQEHSDOLQJHQYDQULFKWOLMQ(&),1'6&YDNXXWWDDODLWWHHQW¦\WW¦Y¦QGLUHNWLLYLQ(&ROHQQDLVHWYDDWLPXNVHW)5(3DU ODSU«VHQWH '6&G«FODUHTXH FHGLVSRVLWLI HVWFRQIRUPH DX[H[LJHQFHVHVVHQWLHOOHVHWDXWUHVVWLSXODWLRQVSHUWLQHQWHVGHOD'LUHFWLYH(&*(5+LHUGXUFKHUNO¦UW'6&GD¡GLHVHV*HU¦WGHQHUIRUGHUOLFKHQ%HGLQJXQJHQXQG9RUUDXVHW]XQJHQGHU5LFKWOLQLH(&HQWVSULFKW*5(˂˜˞˱ˬ˲˭˞ˮ˹˪˱ˬ˯ˤ'6&ˡˤ˨˻˪ˢ˦˹˱˦˞˲˱˛ˤ˰˲˰˧ˢ˲˛ˢ˜˪˞˦˰˺˩˳˶˪ˤ˩ˢ˱˦˯ˬ˲˰˦˻ˡˤ˯˞˭˞˦˱˛˰ˢ˦˯˧˞˦˩ˢ˹˨ˢ˯˱˦˯˙˨˨ˢ˯˰˴ˢ˱˦˧˚˯˞˪˞˳ˬˮ˚˯˱ˤ˯ˍˡˤˠ˜˞˯(&,7$ &RQ OD SUHVHQWH OD 'LJLWDO 6HFXULW\ &RQWUROV GLFKLDUD FKH TXHVWR SURGRWWR ªFRQIRUPH DL UHTXLVLWL HVVHQ]LDOL HG DOWUH GLVSRVL]LRQL ULOHYDQWL UHODWLYH DOOD 'LUHWWLYD&(125'6&HUNO¨UHUDWGHQQHHQKHWHQHULVDPVYDUPHGGHJUXQQOHJJHQGHNUDYRJºYULJHUHOHYDQWHNUDYLGLUHNWLY()32/'6&RĝZLDGF]DľHXU]ÇG]HQLHMHVWZ]JRGQRĝFL]]DVDGQLF]\PLZ\PDJDQLDPLRUD]SR]RVWDĄ\PLVWRVRZQ\PLSRVWDQRZLHQLDPL'\UHNW\Z\:(3253RUHVWHPHLRD'6&GHFODUDTXHHVWHHTXLSDPHQWRHVW£HPFRQIRUPLGDGHFRP RV UHTXLVLWRV HVVHQFLDLV H RXWUDV GHWHUPLQD©·HV UHOHYDQWHV GD 'LUHFWLYD(&63$3RUODSUHVHQWH'6&GHFODUDTXHHVWHHTXLSRHVW£HQFRQIRUPLGDGFRQORVUHTXLVLWRVHVHQFLDOHV\RWURVUHTXLVLWRVUHOHYDQWHVGHOD'LUHFWLYD(&6:('6&EHNU¦IWDUK¦UPHGDWWGHQQDDSSDUDWXSSI\OOHUGHY¦VHQWOLJDNUDYHQRFKDQGUDUHOHYDQWDEHVW¦PPHOVHUL'LUHNWLYHW(&- 29 -
Chapter 13.0 Reference Sheets13.0 Reference SheetsFilloutthefollowinginformationforfuturereferenceandstorethisguideinasafeplace.13.1 System InformationMarkifButtonsareEnabled[F]FIRE[M]Medical[P]PANICTheExitDelayTimeis_______seconds.TheEntryDelayTimeis_______seconds.13.2 Service Contact InformationCentralStationInformationAccount#:___________________Telephone#:__________________InstallerInformation:Company:___________________Telephone#:__________________BatteryInstallation/ServiceDate:_______________________________________________________________IMPORTANT:Ifyoususpectafalsealarmsignalhasbeensenttothecentralmonitoringstation,callthestationtoavoidanunnecessaryresponse.- 30 -
©2016TycoSecurityProducts.AllRightsReserved.TechSupport:1-800-387-3630(Canada&U.S.)or905-760-3000•www.dsc.comThetrademarks,logos,andservicemarksdisplayed onthisdocumentare registeredinthe UnitedStates[or othercountries]. Any misuse  of  the trademarks is strictly prohibited and Tyco Security Products  will  aggressivelyenforce its intellectual propertyrights to the fullest extent of the  law, including pursuit of criminal  prosecutionwherever necessary. All  trademarks not owned by TycoSecurity Products are the  property of their  respectiveowners,andareusedwithpermissionorallowedunderapplicablelaws.Productofferings andspecifications aresubject tochange withoutnotice. Actualproducts mayvaryfrom photos.Notallproductsincludeallfeatures.Availabilityvariesbyregion;contactyoursalesrepresentative.29009783R001