Tyco Safety Sensormatic BIX1000 Business Intelligence Module User Manual BIX1000 Manual Rev3ax

Tyco Safety Products/Sensormatic Business Intelligence Module BIX1000 Manual Rev3ax

Contents

User manual

Download: Tyco Safety Sensormatic BIX1000 Business Intelligence Module User Manual BIX1000 Manual Rev3ax
Mirror Download [FCC.gov]Tyco Safety Sensormatic BIX1000 Business Intelligence Module User Manual BIX1000 Manual Rev3ax
Document ID3782249
Application IDJec/4xhJDJ2/ZGdcn8+/yQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.96kB (349468 bits)
Date Submitted2018-03-15 00:00:00
Date Available2018-03-15 00:00:00
Creation Date2018-03-15 10:11:05
Producing SoftwareGPL Ghostscript 8.64
Document Lastmod2018-03-15 02:11:06
Document TitleMicrosoft Word - BIX1000 Manual_Rev3a.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: Joe-L_Chan

PRELIMINARY
Business Intelligence Accessory (BIX1000)
Installation Guide
BIX1000, BIX1000EA
© 2018 Sensormatic Electronics, LLC
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
1 of 17
*8200-1088-15*
PRELIMINARY
Contents
About this guide ............................................................................................................................................ 3
Additional documentation......................................................................................................................... 3
Technical Support .................................................................................................................................... 3
About the product ......................................................................................................................................... 4
Features .................................................................................................................................................. 4
Compatibility ............................................................................................................................................ 5
Section I: Installation sequence overview ...................................................................................................... 6
Section I: Before you begin ........................................................................................................................... 7
Installation prerequisites ........................................................................................................................... 7
Training ................................................................................................................................................... 7
Cable kit numbers ...................................................................................................................................... 8
System requirements ................................................................................................................................. 8
Firmware requirements ............................................................................................................................ 8
Laptop requirements ................................................................................................................................ 8
Component installation requirements ....................................................................................................... 9
Wiring requirements................................................................................................................................. 9
Tool requirements.................................................................................................................................... 9
Safety .......................................................................................................................................................... 9
Section II: Installing the BIX1000 ................................................................................................................ 10
Overview of steps ..................................................................................................................................... 10
Step 1: Commissioning the BIX1000 ....................................................................................................... 10
Step 2: Connecting the BIX1000 cable to the EAS device ...................................................................... 12
Step 3: Locating the BIX1000 ................................................................................................................... 12
Specifications ............................................................................................................................................. 15
Declarations ............................................................................................................................................... 16
Other declarations .................................................................................................................................... 17
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
2 of 17
*8200-1088-15*
PRELIMINARY
About this guide
This installation guide explains how to install the Business Intelligence Accessory (BIX1000), with the Business
Intelligence Module (BIM1000), to synchronize all Sensormatic-connected devices.
Additional documentation
The following is a list of additional documents related to this installation:
• Business Intelligence Module (BIM1000) Installation Guide, 8200-1088-03.
• Business Intelligence Module (BIM1000) and Business Intelligence Accessory (BIX1000) Setup Guide,
8200-1088-01.
• Ultra Post® IV AMS-1012 Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-05.
• Ultra Post® VI AMS-1014 Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-06.
• Ultra 1.8 Meter ABS Pedestal Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-07.
• AMB9010-IPS and AMB-1200 Label Deactivator Controller Business Intelligence Accessory (BIX1000)
Cable Kit Installation Guide, 8200-1088-08.
• AMS-9050 Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-09.
• AMS-9040 Controller Business Intelligence Accessory (BIX1000) Cable Kit Installation Guide,
8200-1088-10.
• AMS-9060 Controller and AMS-1170-2C/4C Controller Business Intelligence Accessory (BIX1000) Cable
Kit Installation Guide, 8200-1088-11.
• ZBSMPROE ScanMax® Pro Label Deactivator Controller Business Intelligence Accessory (BIX1000) Cable
Kit Installation Guide, 8200-1088-12.
• IDKM-10XX/AMK-10XX SuperTag® Detacher Business Intelligence Accessory (BIX1000) Cable Kit
Installation Guide, 8200-1088-13.
• AMB-2011/AMB-1101/ZBAMB9010 EAS Label Deactivator Business Intelligence Accessory (BIX1000)
Cable Kit Installation Guide, 8200-1088-16.
• Business Intelligence Accessory (BIX1000) Extension Cable Kit Installation Guide, 8200-1088-14.
Technical Support
For product bulletins, and the most recent updates to this guide, visit https://sensormaticsecurelogin.com
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
3 of 17
*8200-1088-15*
PRELIMINARY
About the product
The BIX1000 is a wireless adapter with an integrated antenna that connects an Electronic Article Surveillance
(EAS) detector, deactivator, or detacher system to the BIM1000 using IEEE 802.15.4 wireless protocol.
The BIX1000, as shown in Figure 1, connects to the BIM1000 to synchronize all in-store Sensormaticconnected devices, to collect data and to provide a health status for all connected devices. The data collected
includes alarms, events, and people-counting statistics. It also collects alarm response times to help eliminate
false deactivation and detection alarms at store exits.
Customers can use a desktop browser to log into a TrueVUE reporting platform, or Shrink Management as a
Service (SMaaS) platform to access daily data reports from all the connected devices.
The customer can also use the Device Mobile App (BIZ1000), which is compatible with iOS and Android smart
devices, or they can use the BIM1000 Manager Interface, to monitor store-wide EAS device health, counts and
events in real-time.
Important: You must install the BIM1000 before you install the BIX1000.
Features
The BIX1000 has the following features:
• It is auto-discovered by the BIM1000 after commissioning.
• It uses the wireless IEEE 802.15.4 Standard for communications.
• It has external LED status and signal strength indicators.
• It has Micro USB Type B access for commissioning.
Figure 1. BIX1000
RS-485 port
Status LED indicator
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
Signal strength LED indicators
Micro USB port
4 of 17
*8200-1088-15*
PRELIMINARY
Compatibility
The Business Intelligence Accessory (BIX1000) is compatible with the following devices:
• The Ultra Post® IV AMS-1012 Pedestal.
• The Ultra Post® VI AMS-1014 Pedestal.
• The Ultra 1.8 Meter ABS Pedestal.
• The AMS-9060 Controller.
• The AMS-9050 Controller.
• The AMS-9040 Controller.
• The AMS-1080 Controller.
• The AMS-1170-2C/4C Controller.
• The ZBAMB9010 EAS Label Deactivator Controller.
• The AMB9010-IPS EAS Label Deactivator Controller.
• The ZBSMPROE ScanMax® Pro Label Deactivator Controller.
• The AMB-1200C EAS Label Deactivator Controller.
• The AMK-1000 and the AMK-1010 SuperTag® Detacher.
• The IDKM-1000 and the IDKM-1010 SuperTag® Detacher.
• The AMB-2011 Value Pad II Countertop EAS Label Deactivator.
• The AMB-1101 VersaPass II Countertop EAS Label Deactivator.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
5 of 17
*8200-1088-15*
PRELIMINARY
Section I: Installation sequence overview
Figure 2 gives an overview of the complete installation sequence you must follow when you install a BIM1000 and a BIX1000.
You must install the BIM1000 before you install the BIX1000.
Figure 2. BIM1000 and BIX1000 complete installation sequence
Step 2:
Step 1:
Before you begin:
Commission
the
Install the
Planning and
BIX1000
BIM1000
prerequisites
Confirm all the
prerequisites in
Section I are
complete before
beginning
installation
Install the
BIM1000. Turn
on the BIM1000,
and program the
PAN ID and the
Channel
Step 5:
Validate BIM1000
configuration
Step 6:
Validate BIM1000
remote connectivity
Validate the
complete
BIM1000 and
BIX1000
configuration
Validate the
remote
connectivity
and data
transportation
of the BIM1000
Commission
the BIX1000
Step 3:
Install the BIX1000
cable kits
Install the
relevant
BIX1000 cable
kit, and
configure the
EAS devices
Step 4:
Install and locate
the BIX1000
Install and
locate the
BIX1000
Important: This installation guide only describes the following steps in the complete BIM1000 and BIX1000 installation sequence:
• Before you begin: Planning and prerequisites
• Step 2: Commission the BIX1000
• Step 4: Install and locate the BIX10000
8200-1088-15, REV 2C
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
6 of 17
*8200-1088-15*
PRELIMINARY
Section I: Before you begin
Before you install the BIX1000, ensure that you adhere to the criteria outlined in the following sections.
Installation prerequisites
This section outlines the prerequisites you need before you install the BIX1000.
To install the BIX1000, you must have the following criteria in place before you proceed:
• Have you completed the necessary training required to commission the BIM1000 and BIX1000?
• Did you download the supporting firmware version for the BIX Firmware Tool?
• Did you download the supporting firmware version for the EAS devices that you are connecting to each
BIX1000?
• Is the BIM1000 installed?
• Is the BIM1000 turned on, and programmed with the Personal Area Network (PAN) ID and the Channel?
For information on configuring the radio settings, refer to the Configuring the BIM1000 section in the
Business Intelligence Model (BIM1000) and Business Intelligence Accessory (BIX1000) Setup Guide,
8200-1088-01.
Training
WARNING: Do not attempt to install and commission the BIX1000 unless you have completed the Wireless
Device Manager (BIM/BIX) Training Curriculum.
To install a Business Intelligence Accessory (BIX1000), you must complete the following technical training
modules:
• BIM and BIX Installation Technical Training.
• BIM Configuration Technical Training.
• Optional: SMaaS Overview Sales Training.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
7 of 17
*8200-1088-15*
PRELIMINARY
Cable kit numbers
Table 1 lists the cable kit numbers for the devices that are compatible to install with a BIX1000.
Table 1. BIX1000 cable kit numbers, cable part numbers, and installation guide numbers
Description
Ultra Post® IV AMS-1012 Pedestal
The Ultra Post® VI AMS-1014 Pedestal
Ultra 1.8 Meter ABS Pedestal
AMB9010-IPS and AMB-1200 EAS Label Deactivator
Controller
AMS-9060 Controller and AMS-1170-2C/4C Controller
AMS-9050 Controller
AMS-9040 Controller
ZBSMPROE ScanMax® Pro Label Deactivator
Controller
IDKN-10XX/AMK-10XX SuperTag® Detacher
Business Intelligence Accessory BIX1000 Extension
Cable Kit
AMB-2011 Value Pad II Countertop EAS Label
Deactivator, AMB-1101 VersaPass II Countertop EAS
Label Deactivator, and ZBAMB9010 EAS Label
Deactivator Controller
Cable kit number
0352-0710-01
0352-0711-01
0352-0757-01
0352-0696-01
Cable part number
0652-0890-01
0652-0891-01
0652-0893-01
0652-0889-01
Installation guide
8200-1088-05
8200-1088-06
8200-1088-07
8200-1088-08
0352-0695-01
0352-0694-01
0352-0693-01
0352-0760-01
0652-0888-01
0652-0887-01
0652-0886-01
0652-0845-01
8200-1088-11
8200-1088-09
8200-1088-10
8200-1088-12
0352-0697-01
0352-0765-01
0652-0892-01
0652-0894-01
8200-1088-13
8200-1088-14
0352-0780-01
0652-0898-01
8200-1088-16
System requirements
This section outlines the system requirements you need to install a BIX1000.
Firmware requirements
In order to support the installation of the BIX1000, you must download the BIX Firmware Tool from
https://sensormaticsecurelogin.com/.
To download the BIX Firmware Tool, complete the following steps:
1. Open a web browser and launch https://sensormaticsecurelogin.com/.
2. Enter your valid logon information, and click Login.
3. From the Tech Support menu, click EAS.
4. Click Software Download.
5. Click BIX Firmware Tool Vx.xx
6. To download the software bundle, click the link, and save the file to a local folder on your laptop.
7. Log out of www.sensormaticsecurelogin.com/.
8. On your laptop, rename the file you saved to an .exe file. Click the executable file, and click Run.
9. Follow the setup wizard instructions to save the software on your laptop.
Note: Files save to the following location: C:\Program Files\Sensormatic\BIX Software Bundle
x.x. (Program Files (x86) for 64 bit machines).
Laptop requirements
Your laptop must have a USB port to connect to the BIX1000.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
8 of 17
*8200-1088-15*
PRELIMINARY
Component installation requirements
This section outlines the component installation requirements to install a BIX1000.
Wiring requirements
For more information on wiring requirements, see Table 1.
Tool requirements
You require the following tools to install the BIX1000:
• A #2 Phillips head screwdriver.
• A small slotted screwdriver.
• A drill with a 3/32 inch (2.38 millimeter) drill bit.
• A micro USB cable, 6003-0313-01, to connect to the BIX1000.
Safety
You must adhere to the following safety instructions when you install a BIX1000:
WARNING: Risk of electric shock
Disconnect all power sources before servicing.
• You must use plenum-rated cables, unless the cables are in raceways.
• Installation of the BIX1000 must comply with the latest national electrical codes, national fire code, and all
applicable local codes and ordinances. National or local wiring codes may differ between regions.
Adherence to these codes supersedes instructions in this document.
• You must observe and respect all the safety instructions in this installation guide, and the operation of the
BIX1000.
• You must mount the BIX1000 only as instructed in this installation guide. Mounting the BIX1000 any other
way can affect its operation.
• The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications
to this equipment. Such modifications can void the user’s authority to operate the equipment.
• You must install the antennas for this transmitter with a separation distance of at least 20 centimetres
(8 inches) from all persons, and must not be collocated or operating in conjunction with any other antenna
or transmitter.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
9 of 17
*8200-1088-15*
PRELIMINARY
Section II: Installing the BIX1000
This section outlines how to install a Business Intelligence Accessory (BIX1000).
Important: You must install the BIM1000 before you install the BIX1000 to verify the signal strength is
sufficient in the selected mounting location.
Overview of steps
This section gives an overview of the necessary steps to install a BIX1000:
• Step 1: Commissioning the BIX1000
• Step 2: Connecting the BIX1000 cable to the EAS device
• Step 3: Locating the BIX1000
Step 1: Commissioning the BIX1000
Before you secure the BIX1000, you must commission it in order to test different mounting locations and to
verify signal strength.
Note: For more information on how to commission the BIX1000, refer to the Business Intelligence Model
(BIM1000) and Business Intelligence Accessory (BIX1000) Setup Guide, 8200-1088-01.
To commission the BIX1000, complete the following steps:
1. If installing the BIX1000EA module, locate the SMA antenna, 3411-0024-01, from the BIX1000 installation
kit, and screw the SMA antenna into the SMA connection port on the BIX1000EA.
Figure 3. SMA antenna to SMA connector
SMA antenna, 3411-0024-01
BIX1000EA module
SMA connection port
2. Connect the micro USB cable, 6003-0313-01, to the BIX1000 micro USB port. For the location of the USB
port, see item D in Figure 1, on page 4.
3. Connect the opposite end of the micro USB cable to the USB port on your laptop.
Note: The laptop powers the BIX1000 through the USB port.
4. Wait 15 seconds for the BIX1000 boot sequence to complete.
5. When the BIX1000 boot sequence completes, launch the BIX Firmware Tool you downloaded preinstallation.
6. Complete the following steps to update the firmware on the BIX1000:
a. In the Controller Download pane, click Browse, and then select the supporting firmware version for the
BIX1000.
b. Click Start Flash Download.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
10 of 17
*8200-1088-15*
PRELIMINARY
Note: If an error occurs during the download, you must close the BIX Firmware Tool, disconnect the device
and then repeat steps 2 to 6.
7. After flash download, complete the following steps to establish communication between the BIM1000 and
the BIX1000:
Important: In the following steps, ensure you save the changes to each individual parameter before you
change the next parameter.
a. Open the BIM Web Launch Tool, and from the BIM Configuration menu, click Radio Settings.
Record the values in the PAN ID and Channel fields, and then close the BIM Web Launch Tool.
b. Return to the BIX Firmware Tool window.
c.
In the PAN ID field enter the PAN ID value you recorded for the BIM1000, and click the Antenna
icon button to save the changes. For the location of the save button, see Figure 4.
Note: The PAN ID is limited to the hex characters A-F and 0-9. The PAN ID you set for the BIX1000
must match the PAN ID set for the BIM1000 to establish communication between the two devices.
d. In the Channel field, enter the Channel value you recorded from the BIM1000, and click the
Antenna icon button to save the changes.
Note: You can set a value from 1 to 26 for IEEE 802.15.4 radio frequencies.
e. In the Tx Power field, enter the Tx power value for the country of use, as shown in Table 2. Click
the Antenna icon button to save the changes.
Table 2. BIM1000 and BIX1000 TX power
Device
BIM1000
BIX1000
BIX1000EA
TX power, North America
197 (20dB)
197 (20dB)
220 (20db)
TX power, Europe
57 (10dB)
78 (10dB)
89 (10db)
8. Optional: In the Location field, enter a description of the location of the BIX1000, for example, East
Entrance. Click the Antenna icon button to save the changes
Note: Entering a location description helps to locate devices after installation.
Figure 4. BIX Firmware Tool window
Antenna icons,
click to save
parameters
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
11 of 17
*8200-1088-15*
PRELIMINARY
9. With the BIX1000 connected to your laptop, temporarily place the BIX1000 in the area where you are
installing it to validate the signal strength. For information on the BIX1000 signal strength indicators, see
Step 3: Locating the BIX1000.
Note: When validating the signal strength, ensure you are within the coverage range of the BIM1000.
10. Close the BIX Firmware Tool.
Important: You must close the BIX Firmware Tool before you disconnect the micro USB cable from the
BIX1000. If you do not close the BIX Firmware Tool first, you can lock the drivers for the BIX1000 and the
app may not connect to the BIX1000. If this occurs, you must restart your laptop to resolve the issue.
11. Disconnect the micro USB cable, 6003-0313-01, from the BIX1000.
Step 2: Connecting the BIX1000 cable to the EAS device
You must connect the BIX1000 to compatible EAS devices using the appropriate cable kit. The RJ45 end of
each cable kit is labelled to indicate which end of the cable connects to the RS-485 port on the BIX1000. For
the location of the RS-485 port on the BIX1000, see item A in Figure 1.
To connect the BIX1000 to a compatible EAS device, complete the following step:
• Select the EAS device you are installing from Table 1, and connect the EAS device to the BIX1000 as
described in the relevant installation guide.
Note: When you connect the EAS device to the BIX1000, the Status LED on the BIX1000 should change to
solid green within 20 seconds. For information on the BIX1000 status LEDs, see Table 4.
Step 3: Locating the BIX1000
Adhere to the following guidelines when determining the installation location of the BIX1000:
• Do not directly hold the BIX1000 module because your body and hand can detune the antenna.
• The BIX1000 can be orientation sensitive at the periphery of its range to the BIM1000.
• The wireless communication between the BIM1000 and the BIX1000 solution is most effective when the
modules are within a direct line of sight. Avoid placing the BIX1000 modules in metal enclosures or deep
underneath counters. Placing the BIX1000 on a higher mounting location can extend its signal strength.
Important: If you connect the BIX1000 to an AMS-9060 controller, an AMS-9050 controller, or an AMS-9040
controller, do not secure the BIX1000 to the case of the controller.
To locate the BIX1000 correctly, complete the following steps:
1. After you connect the BIX1000 to the EAS device using the appropriate cable installation kit, determine the
location of the BIX1000.
Notes:
• You must place the BIX1000 a minimum of 2 feet (24 inches) from the BIM1000.
• Table 3 lists the expected maximum line of sight range from the BIM1000 module to the BIX1000
module for each region. The maximum line of sight ranges are based on environments free of
obstructions and interference, the range can significantly degrade from the specified maximums.
Table 3. Expected maximum line of sight ranges from the BIM1000 to the BIX1000
Modules
Region
Expected maximum line of sight range
BIM1000 to BIX1000
BIM1000 to BIX1000EA
BIM1000 to BIX1000
EU
EU
US
76.2 meters (250 feet)
106.7 meters (350 feet)
106.7 meters (350 feet)
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
12 of 17
*8200-1088-15*
PRELIMINARY
2. Optional: If you need to locate the BIX1000 further away from the EAS device for improved signal reception
or for mounting purposes, install the BIX1000 Extension Cable Kit, 0352-0765-01, as described in the
Business Intelligence Accessory (BIX1000) Extension Cable Kit Installation Guide, 8200-1088-14.
Note: Use the BIX1000 Cable Extension Kit to relocate the BIX1000 module up to 3.3 meters (10 feet)
away from the EAS device you are connecting the BIX1000 to.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
13 of 17
*8200-1088-15*
PRELIMINARY
3. Ensure that the status LED on the BIX1000 is green. For information on the status LED descriptions, see
Table 4.
Table 4. BIX1000 status LED description
BIX1000 status LED color
BIX1000 status description
No status LED displaying
Status LED displaying green
Status LED flashing amber quickly
Status LED flashing amber slowly
Status LED flashing red
Powered off or in Boot Loader Mode
Operating correctly
Attempting communication with an EAS device
The Phase Lock Loop (PLL) is unlocked, and indicates a synchronization error
There is no communication between the BIX1000 and the BIM 1000
4. To ensure a strong signal strength, select one of the following options:
• Ensure the signal strength LEDs on the BIX1000 display at least one green LED. If it does not, move
the BIX1000 until it displays one or more green LEDs. For information on the signal strength
indicators on the BIX1000, see Table 5.
• Connect the BIX1000 to a laptop and wait for the BIX1000 boot sequence to complete as described
in steps 2 to 5 on page 10, and then use the BIX Firmware Tool to determine the RSSI value. For
more information, refer to the Business Intelligence Module (BIM1000) and Business Intelligence
Accessory (BIX1000) Setup Guide, 8200-1088-01.
Table 5. BIX1000 signal strength LED description
BIX1000 signal strength LED color
RX signal strength description
No green signal strength LEDs displaying
One green signal strength LED displaying
Two green signal strength LEDs displaying
Three green signal strength LEDS displaying
Signal strength is below -85 decibels
Signal strength is -85 to -75 decibels
Signal strength is -75 to -60 decibels
Signal strength is above -60 decibels
5. When you identify an ideal mounting location, locate the alcohol pads, 1600-0033, from the BIX1000
Installation Kit, 0352-0733-01, and use the alcohol pads to clean the surface area of the mounting location.
6. Remove the release liner from the adhesive pad on the BIX1000, and secure it to the correct location near
or on the EAS device. For more information on a specific EAS device, refer to the relevant installation guide
listed in Table 1.
7. Optional: If you need to secure the BIX1000 using the screws supplied in the installation kit, complete the
following steps:
a. Locate the BIX1000 back cover plate, 0404-1244-01, from the BIX1000 Installation Kit,
0352-0733-01.
b. Use the BIX1000 back cover plate as a template, and mark the location of the pilot holes on the
mounting surface.
c.
Remove the BIX1000 back cover, and using a drill with a 3/32 inch or 2.38 millimeter drill bit, drill
two mounting holes in the mounting surface.
d. Insert the two screws, 5810-2042-120, from the installation kit into the BIX1000 back cover, and
into the two mounting holes in the mounting surface.
e. Ensure the two mounting screws are recessed below the plastic surface, and secure the back cover
to the mounting surface.
Note: The screw holes on the BIX1000 back cover plate are symmetrical. The other features on the
BIX1000 back cover plate are not symmetrical because they accommodate the micro USB and the
RS-485 ports.
8. Secure the BIX1000 to its mounting surface.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
14 of 17
*8200-1088-15*
PRELIMINARY
Specifications
Electrical
Power supply
Primary input .........................................................................................................................................................................
..................................................... / 5V – 24VDC input, Sync and RS485 through RJ45 8 pin header with LEDs for RS485.
Environmental
Operating temperature..................................................... ........................................................ 0°C to 50°C (14°F to 122°F)
Relative humidity ............................................................. ............................................................ 0 to 90% non-condensing
Enclosure Rating ............................................................. ..................................................................................... UL94 V-O
Evaluated for altitudes less than 2,000 meters (6,561.68 feet)
Mechanical
Material: ........................................................................... ..............................................................................................ABS
Color: .............................................................................. ..................................................................................... Light grey
Dimensions: .................................................................... .................................................. 58.6 mm X 46.7 mm X 24.9 mm
Weight (approx.): ............................................................ ....................................................................... 32.66 g (0.072 lbs)
Dimensions
Figure 5. BIX1000 dimensions
58.5 mm
47 mm
52.6 mm
58.5 mm
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
15 of 17
*8200-1088-15*
PRELIMINARY
Declarations
Model: BIX1000
Regulatory information
Radio
Frequency of operation
Type.......................................................... .............................................................................................................. BIX1000
Frequency band............................. .......................................................................................................... .2400-2483.5 MHz
Maximum power ................................... ..................................................................................................... 10 mW in the EU
........................................................................................................................................................................ 100 mW in NA
If frequency is selectable for your model, select only the country in which you are using the device. Any other selection will make the
operation of this device illegal.
Approved antennas
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain
maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada.
Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire
à l’établissement d’une
communication satisfaisante.
This radio transmitter IC: 3506A-BIX1000 has been approved by Industry Canada to operate with the antenna types listed below with the
maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having
a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio IC: 3506A-BIX1000 a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés cidessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette
liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
Pulse/Larsen W1027
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... .......................................................................................................... 3.2 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
Pulse/Larsen W1038
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... .......................................................................................................... 3.8 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
L-Com model HG2403RD-RSF
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... ........................................................................................................... 3.0 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
Antenova model SRCW004
Polarization ..................................................... ............................................................................................................ Linear
Composite gain ............................................... .......................................................................................................... 2.5 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
FCC ID: BVCBIX1000
This device complies with part 15 of the FCC Rules. This device complies with Industry Canada’s licence-exempt RSSs.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
México NOM 121: BIX1000
La operación de este equipo está sujeta a las siguientes dos condiciones:
1) es posible que este equipo o dispositivo no cause interferencia perjudicial y
2) este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su propia operación no deseada.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
16 of 17
*8200-1088-15*
PRELIMINARY
INTERNATIONAL ID: BIX1000
EMC ....................................................... .................................................................................................... 47 CFR, Part 15
............................................................................................................................................................................ EN 300 328
......................................................................................................................................................................... EN 301 489-1
......................................................................................................................................................................... EN 301 489-3
....................................................................................................................................................................... EN 301 489-17
................................................................................................................................................................................ RSS 210
Safety.......................................................... ................................................................................................. UL/EN 60950-1
............................................................................................................................................................... CSA C22.2.60950-1
EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics,
LLC, the party responsible for FCC compliance, could void the user’s authority to operate the equipment and could create a hazardous
condition.
See About this guide on page 3.
Other declarations
WARRANTY DISCLAIMER: Sensormatic Electronics, LLC makes no representation or warranty with respect to the contents hereof
and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic
Electronics, LLC reserves the right to revise this publication and make changes from time to time in the content hereof without
obligation of Sensormatic Electronics, LLC to notify any person of such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private
expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data
marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013.
Unpublished - rights reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: Sensormatic is a registered trademark of Sensormatic Electronics, LLC. Other product names mentioned
herein may be trademarks or registered trademarks of Sensormatic or other companies.
No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics, LLC.
8200-1088-15, REV 3a
BUSINESS INTELLIGENCE ACCESSORY (BIX1000)
INSTALLATION GUIDE
17 of 17
*8200-1088-15*

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
Page Count                      : 17
Create Date                     : 2018:03:15 10:11:05+08:00
Title                           : Microsoft Word - BIX1000 Manual_Rev3a.docx
Producer                        : GPL Ghostscript 8.64
Author                          : Joe-L_Chan
Creator                         : PScript5.dll Version 5.2.2
Modify Date                     : 2018:03:15 02:11:06Z
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BVCBIX1000

Navigation menu