Tyco Safety Sensormatic BIX1000 Business Intelligence Module User Manual REV

Tyco Safety Products/Sensormatic Business Intelligence Module REV

Contents

User manual_REV

Download: Tyco Safety Sensormatic BIX1000 Business Intelligence Module User Manual  REV
Mirror Download [FCC.gov]Tyco Safety Sensormatic BIX1000 Business Intelligence Module User Manual  REV
Document ID3797305
Application IDJec/4xhJDJ2/ZGdcn8+/yQ==
Document DescriptionUser manual_REV
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.66kB (308279 bits)
Date Submitted2018-03-27 00:00:00
Date Available2018-04-29 00:00:00
Creation Date2018-03-20 15:00:15
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2018-03-20 15:00:22
Document TitleBusiness Intelligence Transciver (BIM1000) Installation Guide, 8z108801a
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: Mary White & Aisling Burke

PRELIMINARY
Wireless Device Module (BIX1000)
Installation Guide
BIX1000
© 2018 Sensormatic Electronics, LLC
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3D
1 of 16
*8200-1088-15*
PRELIMINARY
Contents
About this guide .................................................................................................................................................. 3
Additional documentation .............................................................................................................................. 3
Technical Support ......................................................................................................................................... 3
Training ......................................................................................................................................................... 3
About the product ............................................................................................................................................... 4
Features ........................................................................................................................................................ 4
Compatibility .................................................................................................................................................. 5
Cable kit numbers ......................................................................................................................................... 5
Tool requirements ......................................................................................................................................... 6
Section I: Before you begin ................................................................................................................................ 6
System requirements ....................................................................................................................................... 6
Firmware requirements ................................................................................................................................. 6
Laptop requirements ..................................................................................................................................... 6
Wiring requirements ...................................................................................................................................... 6
Safety ................................................................................................................................................................. 7
Installation prerequisites ................................................................................................................................. 7
Section II: Installation sequence overview ......................................................................................................... 8
Section III: Installing the BIX1000 ...................................................................................................................... 9
Overview of steps............................................................................................................................................. 9
Step 1: Connecting the BIX1000 cable to the EAS device ........................................................................... 9
Step 2: Commissioning the BIX1000 .............................................................................................................. 9
Step 3: Locating the BIX1000 ........................................................................................................................ 11
Specifications ................................................................................................................................................... 14
Declarations ..................................................................................................................................................... 15
Other declarations .......................................................................................................................................... 16
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3D
2 of 16
*8200-1088-15*
PRELIMINARY
About this guide
This installation guide explains how to install the Wireless Device Module (BIX1000), with the Wireless Device
Manager (BIM1000), to synchronize and aggregate data from all Sensormatic-connected devices.
Additional documentation
The following is a list of additional documents related to this installation:
• Wireless Device Manager (BIM1000) Installation Guide, 8200-1088-03.
• Wireless Device Manager (BIM1000) and Wireless Device Module (BIX1000) Setup Guide, 8200-1088-01.
• Ultra Post® IV AMS-1012 Wireless Device Module (BIX1000) Cable Kit Installation Guide, 8200-1088-05.
• Ultra Post® VI AMS-1014 Wireless Device Module (BIX1000) Cable Kit Installation Guide, 8200-1088-06.
• Ultra 1.8 Meter ABS Pedestal Wireless Device Module (BIX1000) Cable Kit Installation Guide,
8200-1088-07.
• AMB9010-IPS and AMB-1200 Label Deactivator Controller Wireless Device Module (BIX1000) Cable Kit
Installation Guide, 8200-1088-08.
• AMS-9050 Controller Wireless Device Module (BIX1000) Cable Kit Installation Guide, 8200-1088-09.
• AMS-9040 Controller Wireless Device Module (BIX1000) Cable Kit Installation Guide, 8200-1088-10.
• AMS-9060 Controller and AMS-1170-2C/4C Controller Wireless Device Module (BIX1000) Cable Kit
Installation Guide, 8200-1088-11.
• ZBSMPROE ScanMax® Pro Label Deactivator Controller Wireless Device Module (BIX1000) Cable Kit
Installation Guide, 8200-1088-12.
• IDKM-10XX/AMK-10XX SuperTag® Detacher Wireless Device Module (BIX1000) Cable Kit Installation
Guide, 8200-1088-13.
• AMB-2011/AMB-1101/ZBAMB9010 EAS Label Deactivator Wireless Device Module (BIX1000) Cable Kit
Installation Guide, 8200-1088-16.
• Wireless Device Module (BIX1000) Extension Cable Kit Installation Guide, 8200-1088-14.
• AMS-1080 Controller Wireless Device Module (BIX1000) Cable Kit Installation Guide, 8200-1088-17.
Technical Support
For product bulletins, and the most recent updates to this guide, visit https://sensormaticsecurelogin.com
Training
WARNING: Do not install a Wireless Device Module (BIX1000) unless you have completed the following
Wireless Device Manager (BIM/BIX) Training Curriculum modules:
• BIM and BIX Installation Technical Training.
• BIM Configuration Technical Training.
• Optional: SMaaS Overview Sales Training.
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3D
3 of 16
*8200-1088-15*
PRELIMINARY
About the product
The Wireless Device Manager (BIM1000) is a wireless access point that uses an IEEE 802.15.4 wireless
standard to connect to the Wireless Device Module (BIX1000).
The Wireless Device Module (BIX1000), as shown in Figure 1, uses the IEEE 802.15.4 wireless protocol to
connect to the Wireless Device Manager (BIM1000) to synchronize all in-store Sensormatic-connected
deactivation and detection controllers, to collect data and to provide a health status for all the connected
devices.
The synchronization between the deactivation and the detection controllers minimizes failed deactivation at the
Point-of-Sale (POS) and nuisance alarms at the store exit area. The data collected includes alarms, events,
and people-counting statistics. It also collects alarm input responses through an Android tablet device.
Customers can use a desktop browser to log into a TrueVUE reporting platform, or a Shrink Management as a
Service (SMaaS) platform, to access historical daily data reports from all the connected devices. The customer
can also use an Android tablet device for alarm input responses.
Important: You must install the Wireless Device Manager (BIM1000) before you install the Wireless Device
Module (BIX1000).
Features
The Wireless Device Module (BIX1000) has the following features:
• It is auto-discovered by the BIM1000 after commissioning.
• It uses the wireless IEEE 802.15.4 Standard for communications.
• It has external LED status and signal strength indicators.
• It has Micro USB Type B access for commissioning.
Figure 1. BIX1000
RS-485 port
Status LED indicator
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
Signal strength LED indicators
Micro USB port
8200-1088-15, REV 3D
4 of 16
*8200-1088-15*
PRELIMINARY
Compatibility
The Wireless Device Module (BIX1000) is compatible with the following devices:
• The Ultra Post® IV AMS-1012 Pedestal.
• The Ultra Post® VI AMS-1014 Pedestal.
• The Ultra 1.8 Meter ABS Pedestal.
• The AMS-9060 Controller.
• The AMS-9050 Controller.
• The AMS-9040 Controller.
• The AMS-1080 Controller.
• The AMS-1170-2C/4C Controller.
• The ZBAMB9010 EAS Label Deactivator Controller.
• The AMB9010-IPS EAS Label Deactivator Controller.
• The ZBSMPROE ScanMax® Pro Label Deactivator Controller.
• The AMB-1200C EAS Label Deactivator Controller.
• The AMK-1000 and the AMK-1010 SuperTag® Detacher.
• The IDKM-1000 and the IDKM-1010 SuperTag® Detacher.
• The AMB-2011 Value Pad II Countertop EAS Label Deactivator.
• The AMB-1101 VersaPass II Countertop EAS Label Deactivator.
Cable kit numbers
Table 1 lists the cable kit numbers for the EAS devices that are compatible to install with a Wireless Device
Module (BIX1000).
Table 1. BIX1000 cable kit numbers, cable part numbers, and installation guide numbers
Description
Ultra Post® IV AMS-1012 Pedestal
The Ultra Post® VI AMS-1014 Pedestal
Ultra 1.8 Meter ABS Pedestal
AMB9010-IPS and AMB-1200 EAS Label Deactivator
Controller
AMS-9060 Controller and AMS-1170-2C/4C Controller
AMS-9050 Controller
AMS-9040 Controller
ZBSMPROE ScanMax® Pro Label Deactivator
Controller
IDKN-10XX/AMK-10XX SuperTag® Detacher
Wireless Device Module BIX1000 Extension Cable Kit
AMB-2011 Value Pad II Countertop EAS Label
Deactivator, AMB-1101 VersaPass II Countertop EAS
Label Deactivator, and ZBAMB9010 EAS Label
Deactivator Controller
AMS-1080 Controller
Cable kit number
0352-0710-01
0352-0711-01
0352-0757-01
0352-0696-01
Cable part number
0652-0890-01
0652-0891-01
0652-0893-01
0652-0889-01
Installation guide
8200-1088-05
8200-1088-06
8200-1088-07
8200-1088-08
0352-0695-01
0352-0694-01
0352-0693-01
0352-0760-01
0652-0888-01
0652-0887-01
0652-0886-01
0652-0845-01
8200-1088-11
8200-1088-09
8200-1088-10
8200-1088-12
0352-0697-01
0352-0765-01
0352-0780-01
0652-0892-01
0652-0894-01
0652-0898-01
8200-1088-13
8200-1088-14
8200-1088-16
0352-0789-01
0652-0901-01
8200-1088-17
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3D
5 of 16
*8200-1088-15*
PRELIMINARY
Tool requirements
You require the following tools to install the Wireless Device Module (BIX1000):
• A #2 Phillips head screwdriver.
• A small slotted screwdriver.
• A drill with a 3/32 inch (2.38 millimeter) drill bit.
• A micro USB cable, 6003-0313-01, to connect to the BIX1000.
Section I: Before you begin
Before you install the Wireless Device Module (BIX1000), ensure that you adhere to the criteria in the following
sections.
System requirements
This section outlines the system requirements that you need to install a BIX1000.
Firmware requirements
To support the installation of the BIX1000, download the BIX Firmware Tool from
https://sensormaticsecurelogin.com/.
To download the BIX Firmware Tool, complete the following steps:
1. Open a web browser and launch https://sensormaticsecurelogin.com/.
2. Enter your valid log on information, and click Login.
3. From the Tech Support menu, click EAS.
4. Click Software Download.
5. Click BIX Firmware Tool.
6. To download the software bundle, click the link, and save the file to a local folder on your laptop.
7. Log out of www.sensormaticsecurelogin.com/.
8. On your laptop, rename the file that you saved to an .exe file. Click the executable file, and click Run.
9. Follow the setup wizard instructions to save the software on your laptop.
Note: Files save to the following location: C:\Program Files\Sensormatic\BIX Software Bundle
(Program Files (x86) for 64 bit machines).
Laptop requirements
Your laptop must have a USB port to connect to the Wireless Device Module (BIX1000).
Wiring requirements
For information on wiring requirements, see Table 1.
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3D
6 of 16
*8200-1088-15*
PRELIMINARY
Safety
You must adhere to the following safety instructions when you install a Wireless Device Module (BIX1000):
WARNING: Risk of electric shock
Disconnect all power sources before servicing.
• You must use plenum-rated cables, unless the cables are in raceways.
• Installation of the BIX1000 must comply with the latest national electrical codes, national fire code, and all
applicable local codes and ordinances. National or local wiring codes may differ between regions.
Adherence to these codes supersedes instructions in this document.
• You must observe and respect all the safety instructions in this installation guide, and the operation of the
BIX1000.
• You must mount the BIX1000 only as instructed in this installation guide. Mounting the BIX1000 any other
way can affect its operation.
• The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications can void the user’s authority to operate the
equipment.
• You must install the antennas for this transmitter with a separation distance of at least 20 centimetres
(8 inches) from all persons, and must not be co-located or operating in conjunction with any other
antenna or transmitter.
Installation prerequisites
To install the BIX1000, you must have the following criteria in place before you proceed:
• Have you completed the training required to commission the BIM1000 and BIX1000?
• Did you download the supporting firmware version for the BIX Firmware Tool?
• Did you download the supporting firmware version for the EAS devices that you are connecting to each
BIX1000?
• Is the BIM1000 installed?
• Is the BIM1000 turned on, and programmed with the Personal Area Network (PAN) ID and the Channel?
For information on configuring the radio settings, refer to the Commissioning the Wireless Device
Manager section in the Wireless Device Manager (BIM1000) and Wireless Device Module (BIX1000) Setup
Guide, 8200-1088-01.
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3D
7 of 16
*8200-1088-15*
PRELIMINARY
Section II: Installation sequence overview
Figure 2 gives an overview of the complete installation sequence you must follow when you install a BIM1000 and a BIX1000.
You must install the BIM1000 before you install the BIX1000.
Figure 2. BIM1000 and BIX1000 complete installation sequence
Before you begin:
Planning and
prerequisites
Step 1:
Install the
BIM1000
Confirm all the
prerequisites in
Section I are
complete
before
beginning
Install the
BIM1000. Turn
on the BIM1000,
and program the
PAN ID and the
Ch
Step 5:
Validate BIM1000
configuration
Step 6:
Validate BIM1000
remote connectivity
Validate the
complete
BIM1000 and
BIX1000
configuration
Validate the
remote
connectivity
and data
transportation
of the
Step 2:
Install the BIX1000
cable kits
Install the
relevant
BIX1000 cable
kit, and
configure the
EAS d i
Step 3:
Commission the
BIX1000
Step 4:
Install and locate
the BIX1000
Commission
the BIX1000
Install and
locate the
BIX1000
Important: This installation guide only describes the following steps in the complete BIM1000 and BIX1000 installation sequence:
• Before you begin: Planning and prerequisites
• Step 3: Commission the BIX1000
• Step 4: Install and locate the BIX1000
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3d
8 of 16
*8200-1088-15*
PRELIMINARY
Section III: Installing the BIX1000
This section outlines how to install a Wireless Device Module (BIX1000).
Important: You must install the Wireless Device Manager (BIM1000) before you install the Wireless Device
Module (BIX1000) to verify that the signal strength is sufficient in the selected mounting location.
Overview of steps
This section gives an overview of the steps to install a BIX1000:
• Step 1: Connecting the BIX1000 cable to the EAS device
• Step 2: Commissioning the BIX1000
• Step 3: Locating the BIX1000
Step 1: Connecting the BIX1000 cable to the EAS device
You must connect the BIX1000 to compatible EAS devices using the appropriate cable kit. The RJ45 end of
each cable kit is labelled to indicate which end of the cable connects to the RS-485 port on the BIX1000. For
the location of the RS-485 port on the BIX1000, see item A in Figure 1.
To connect the BIX1000 to a compatible EAS device, complete the following step:
• Select the EAS device you are installing from Table 1, and connect the EAS device to the BIX1000, as
described in the relevant installation guide.
Note: When you connect the EAS device to the BIX1000, the Status LED on the BIX1000 should change to
solid green within 20 seconds. For information on the BIX1000 status LEDs, see Table 4.
Step 2: Commissioning the BIX1000
Before you secure the BIX1000, you must commission it in order to test different mounting locations and to
verify signal strength.
Note: For more information on how to commission the BIX1000, refer to the Wireless Device Manager
(BIM1000) and Wireless Device Module (BIX1000) Setup Guide, 8200-1088-01.
To commission the Wireless Device Module (BIX1000), complete the following steps:
1. If installing the BIX1000EA module, locate the SMA antenna, 3411-0024-01, from the BIX1000 installation
kit, and screw the SMA antenna into the SMA connection port on the BIX1000EA.
Figure 3. SMA antenna to SMA connector on the BIX1000EA
SMA antenna, 3411-0024-01
BIX1000EA module
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
SMA connection port
8200-1088-15, REV 3a
9 of 16
*8200-1088-15*
PRELIMINARY
2. Connect the micro USB cable, 6003-0313-01, to the BIX1000 micro USB port. For the location of the USB
port, see item D in Figure 1, on page 4. Connect the opposite end of the micro USB cable to the USB port
on your laptop.
Note: The laptop powers the BIX1000 through the USB port.
3. Wait 15 seconds for the BIX1000 boot sequence to complete.
4. When the BIX1000 boot sequence completes, launch the BIX Firmware Tool you downloaded preinstallation.
5. Update the firmware on the BIX1000 by completing the following steps:
a. In the Controller Download pane, click Browse, and then select the supporting firmware version for the
BIX1000.
b. Click Start Flash Download.
Note: If an error occurs during the download, you must close the BIX Firmware Tool, disconnect the device,
and then repeat steps 2 to 6.
6. After the flash download, complete the following steps to establish communication between the BIM1000
and the BIX1000:
Important: In the following steps, ensure you save the changes to each individual parameter before you
change the next parameter.
a. Open the BIM Web Launch Tool, and from the BIM Configuration menu, click Radio Settings.
Record the values in the PAN ID and Channel fields, and then close the BIM Web Launch Tool.
b. Return to the BIX Firmware Tool window.
c.
In the PAN ID field enter the PAN ID value you recorded for the BIM1000, and click the Antenna
icon to save the changes. For the location of the save button, see Figure 4.
Note: The PAN ID is limited to the hex characters A-F and 0-9. The PAN ID you set for the BIX1000
must match the PAN ID set for the BIM1000 to establish communication between the two devices.
d. In the Channel field, enter the Channel value you recorded from the BIM1000, and click the
Antenna icon to save the changes.
Note: You can set a value from 11 to 26 for IEEE 802.15.4 radio frequencies.
Regulatory restriction: Do not use channel 25 or channel 26 in North America.
e. In the Tx Power field, enter the Tx power value for the country of use, as shown in Table 2. Click
the Antenna icon to save the changes.
Table 2. BIM1000 and BIX1000 TX power
Device
BIM1000
BIX1000
BIX1000EA
TX power, North America
197 (20dB)
197 (20dB)
220 (20dB)
TX power, Europe
70 (10dB)
94 (10dB)
85 (10dB)
7. Optional: In the Location field, enter a description of the location of the BIX1000, for example, East
Entrance. Click the Antenna icon to save the changes.
Note: Entering a location description helps to locate devices after installation.
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3a
10 of 16
*8200-1088-15*
PRELIMINARY
Figure 4. BIX Firmware Tool window
Antenna icons,
click to save
parameters
8. With the BIX1000 connected to your laptop, temporarily place the BIX1000 in the area where you are
installing it to validate the signal strength. For information on the BIX1000 signal strength indicators, see
Step 3: Locating the BIX1000.
Note: When validating the signal strength, ensure you are within the coverage range of the BIM1000.
9. Close the BIX Firmware Tool.
Important: You must close the BIX Firmware Tool before you disconnect the micro USB cable from the
BIX1000. If you do not close the BIX Firmware Tool first, the drivers for the BIX1000 can lock and the app
may not connect to the BIX1000. If this occurs, you must restart your laptop to resolve the issue.
10. Disconnect the micro USB cable, 6003-0313-01, from the BIX1000.
Step 3: Locating the BIX1000
Adhere to the following guidelines when determining the installation location of the BIX1000:
• Do not directly hold the BIX1000 module because your body and hand can detune the antenna.
• The BIX1000 can be orientation sensitive at the periphery of its range to the BIM1000.
• The wireless communication between the BIM1000 and the BIX1000 solution is most effective when the
modules are within a direct line of sight. Avoid placing the BIX1000 modules in metal enclosures or deep
underneath counters. Placing the BIX1000 on a higher mounting location can extend its signal strength.
Important: If you connect the BIX1000 to an AMS-9060 controller, an AMS-9050 controller, or an AMS-9040
controller, do not secure the BIX1000 to the case of the controller.
To locate the BIX1000 correctly, complete the following steps:
1. After you connect the BIX1000 to the EAS device using the appropriate cable installation kit, determine the
location of the BIX1000.
Notes:
• You must place the BIX1000 a minimum of 2 feet (24 inches) from the BIM1000.
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3a
11 of 16
*8200-1088-15*
PRELIMINARY
• Table 3 lists the expected maximum line of sight range from the BIM1000 module to the BIX1000
module for each region. The maximum line of sight ranges are based on environments free of
obstructions and interference. The range can significantly degrade from the specified maximums.
Table 3. Expected maximum line of sight ranges from the BIM1000 to the BIX1000
Modules
Region
Expected maximum line of sight range
BIM1000 to BIX1000
BIM1000 to BIX1000EA
BIM1000 to BIX1000
EU
EU
US
76.2 meters (250 feet)
106.7 meters (350 feet)
106.7 meters (350 feet)
2. Optional: If you need to locate the BIX1000 further away from the EAS device for improved signal reception
or for mounting purposes, install the BIX1000 Extension Cable Kit, 0352-0765-01, as described in the
Wireless Device Module (BIX1000) Extension Cable Kit Installation Guide, 8200-1088-14.
Note: Use the BIX1000 Cable Extension Kit to relocate the BIX1000 module up to 3.3 meters (10 feet)
away from the EAS device to which you are connecting the BIX1000.
3. Ensure that the status LED on the BIX1000 is green. For information on the status LED descriptions, see
Table 4.
Table 4. BIX1000 status LED description
BIX1000 status LED color
BIX1000 status description
No status LED displaying
Status LED displaying green
Status LED flashing amber quickly
Status LED flashing amber slowly
Status LED flashing red
Powered off or in Boot Loader Mode
Operating correctly
Attempting communication with an EAS device
The Phase Lock Loop (PLL) is unlocked, and indicates a synchronization error
There is no communication between the BIX1000 and the BIM1000
4. To ensure strong signal strength, select one of the following options:
• Ensure the signal strength LEDs on the BIX1000 display at least one green LED. If it does not, move
the BIX1000 until it displays one or more green LEDs. For information on the signal strength
indicators on the BIX1000, see Table 5.
• Connect the BIX1000 to your laptop and wait for the BIX1000 boot sequence to complete as
described in steps 2 to 5 on page 9, and then use the BIX Firmware Tool to determine the Received
Signal Strength Indicators (RSSI) value.
Table 5. BIX1000 signal strength LED description
BIX1000 signal strength LED color
RX signal strength description
No green signal strength LEDs displaying
One green signal strength LED displaying
Two green signal strength LEDs displaying
Three green signal strength LEDS displaying
Signal strength is below -85 decibels
Signal strength is -85 to -75 decibels
Signal strength is -75 to -60 decibels
Signal strength is above -60 decibels
5. When you identify an ideal mounting location, locate the alcohol pads, 1600-0033, from the BIX1000
Installation Kit, 0352-0733-01, and use the alcohol pads to clean the surface area of the mounting location.
6. Remove the release liner from the adhesive pad on the BIX1000, and secure it to the correct location near
or on the EAS device. For more information on a specific EAS device, refer to the relevant installation guide
listed in Table 1.
7. Optional: If you need to secure the BIX1000 using the screws supplied in the installation kit, complete the
following steps:
a. Locate the BIX1000 back cover plate, 0404-1244-01, from the BIX1000 Installation Kit,
0352-0733-01.
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3a
12 of 16
*8200-1088-15*
PRELIMINARY
b. Use the BIX1000 back cover plate as a template, and mark the location of the pilot holes on the
mounting surface.
c.
Remove the BIX1000 back cover, and using a drill with a 3/32 inch or 2.38 millimeter drill bit, drill
two mounting holes in the mounting surface.
d. Insert the two screws, 5810-2042-120, from the installation kit into the BIX1000 back cover, and
into the two mounting holes in the mounting surface.
e. Ensure that the two mounting screws are recessed below the plastic surface, and secure the back
cover to the mounting surface.
Note: The screw holes on the BIX1000 back cover plate are symmetrical. The other features on the
BIX1000 back cover plate are not symmetrical because they accommodate the micro USB and the
RS-485 ports.
8. Secure the BIX1000 to its mounting surface.
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3a
13 of 16
*8200-1088-15*
PRELIMINARY
Specifications
Electrical
Power supply
Primary input .........................................................................................................................................................................
..................................................... / 5V – 24VDC input, Sync and RS485 through RJ45 8 pin header with LEDs for RS485.
Environmental
Operating temperature..................................................... ........................................................ 0°C to 50°C (32°F to 122°F)
Relative humidity ............................................................. ............................................................ 0 to 90% non-condensing
Enclosure Rating ............................................................. ..................................................................................... UL94 V-O
Evaluated for altitudes less than 2,000 meters (6,561.68 feet)
Mechanical
Material: ........................................................................... ..............................................................................................ABS
Color: .............................................................................. ..................................................................................... Light grey
Dimensions: .................................................................... .................................................. 58.6 mm X 46.7 mm X 24.9 mm
Weight (approx.): ............................................................ ....................................................................... 32.66 g (0.072 lbs)
Dimensions
Figure 5. BIX1000 dimensions
58.5 mm
47 mm
52.6 mm
58.5 mm
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3a
14 of 16
*8200-1088-15*
PRELIMINARY
Declarations
Model: BIX1000
Regulatory information
Radio
Frequency of operation
Type.......................................................... .............................................................................................................. BIX1000
Frequency band............................. .......................................................................................................... .2400-2483.5 MHz
Maximum power ................................... ..................................................................................................... 10 mW in the EU
........................................................................................................................................................................ 100 mW in NA
If frequency is selectable for your model, select only the country in which you are using the device. Any other selection will make the operation of
this device illegal.
Approved antennas
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the
transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal
(ou inférieur) approuvé pour l’émetteur par Industrie Canada.
Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte
que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
This radio transmitter IC: 3506A-BIX1000 has been approved by Industry Canada to operate with the antenna types listed below with the maximum
permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the
maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio IC: 3506A-BIX1000 a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et
ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain
est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
Pulse/Larsen W1027
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... .......................................................................................................... 3.2 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
Pulse/Larsen W1038
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... ..........................................................................................................3.8 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
L-Com model HG2403RD-RSF
Polarization ..................................................... .......................................................................................................... Vertical
Composite gain ............................................... ...........................................................................................................3.0 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
Antenova model SRCW004
Polarization ..................................................... ............................................................................................................ Linear
Composite gain ............................................... .......................................................................................................... 2.5 dBi
Impedance .................................................... ......................................................................................................... 50 ohms
FCC ID: BVCBIX1000
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3a
15 of 16
*8200-1088-15*
PRELIMINARY
This device complies with part 15 of the FCC Rules. This device complies with Industry Canada’s licence-exempt RSSs.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
México NOM 121: BIX1000
La operación de este equipo está sujeta a las siguientes dos condiciones:
1) es posible que este equipo o dispositivo no cause interferencia perjudicial y
2) este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su propia operación no deseada.
INTERNATIONAL ID: BIX1000
EMC ....................................................... .................................................................................................... 47 CFR, Part 15
............................................................................................................................................................................ EN 300 328
......................................................................................................................................................................... EN 301 489-1
......................................................................................................................................................................... EN 301 489-3
....................................................................................................................................................................... EN 301 489-17
................................................................................................................................................................................ RSS 210
Safety.......................................................... ................................................................................................. UL/EN 60950-1
............................................................................................................................................................... CSA C22.2.60950-1
EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics, LLC, the party
responsible for FCC compliance, could void the user’s authority to operate the equipment and could create a hazardous condition.
See About this guide on page 3.
Other declarations
WARRANTY DISCLAIMER: Sensormatic Electronics, LLC makes no representation or warranty with respect to the contents hereof and specifically
disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic Electronics, LLC reserves the right
to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics, LLC to notify
any person of such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part
of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set
forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the
Copyright Laws of the United States.
TRADEMARK NOTICE: Sensormatic is a registered trademark of Sensormatic Electronics, LLC. Other product names mentioned herein may be
trademarks or registered trademarks of Sensormatic or other companies.
No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics, LLC.
WIRELESS DEVICE MODULE (BIX1000)
INSTALLATION GUIDE
8200-1088-15, REV 3a
16 of 16
*8200-1088-15*

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Mary White & Aisling Burke
Category                        : EAS
Comments                        : Business Intelligence Module (BIM1000) Installation Guide, 8z108801a
Company                         : Johnson Controls
Create Date                     : 2018:03:20 15:00:15-04:00
Information Classification      : Internal
Keywords                        : BIM1000, BIX1000, BIM, BIX, controllers
MSIP Label 6be 01c 0c-f 9b 3-4dc 4-af 0b-a 82110cc 37cd Application: Microsoft Azure Information Protection
MSIP Label 6be 01c 0c-f 9b 3-4dc 4-af 0b-a 82110cc 37cd Enabled: True
MSIP Label 6be 01c 0c-f 9b 3-4dc 4-af 0b-a 82110cc 37cd Extended MSFT Method: Automatic
MSIP Label 6be 01c 0c-f 9b 3-4dc 4-af 0b-a 82110cc 37cd Name: Internal
MSIP Label 6be 01c 0c-f 9b 3-4dc 4-af 0b-a 82110cc 37cd Ref: https://api.informationprotection.azure.com/api/a1f1e214-7ded-45b6-81a1-9e8ae3459641
MSIP Label 6be 01c 0c-f 9b 3-4dc 4-af 0b-a 82110cc 37cd Set By: jminats@jci.com
MSIP Label 6be 01c 0c-f 9b 3-4dc 4-af 0b-a 82110cc 37cd Set Date: 2018-03-20T15:00:00.9607121-04:00
MSIP Label 6be 01c 0c-f 9b 3-4dc 4-af 0b-a 82110cc 37cd Site Id: a1f1e214-7ded-45b6-81a1-9e8ae3459641
Manager                         : Mark Evans
Modify Date                     : 2018:03:20 15:00:22-04:00
Source Modified                 : D:20180320190001
Language                        : EN-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Metadata Date                   : 2018:03:20 15:00:22-04:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Document ID                     : uuid:b4c94db8-8774-48ef-b1e4-a014c932325d
Instance ID                     : uuid:3ffd55d0-5d93-4c25-9750-6777d44fbed8
Subject                         : 17
Format                          : application/pdf
Title                           : Business Intelligence Transciver (BIM1000) Installation Guide, 8z108801a
Creator                         : Mary White & Aisling Burke
Producer                        : Adobe PDF Library 11.0
Information 0020 Classification : Internal
Page Layout                     : OneColumn
Page Count                      : 16
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BVCBIX1000

Navigation menu