Company Confidential SCANMAX PRO INSTALLATION AND SETUP GUIDE (8200-0054-01, REV. 02) 1 of 5 ZBSMPROZBSMPROZBSMPROZBSMPRO    ScanMax™ Pro ScanMax™ Pro ScanMax™ Pro ScanMax™ Pro     ControllerControllerControllerController    Installation and Setup GuideInstallation and Setup GuideInstallation and Setup GuideInstallation and Setup Guide     ScanMax Antennas Used with ScanMax Antennas Used with ScanMax Antennas Used with ScanMax Antennas Used with     this Controllerthis Controllerthis Controllerthis Controller    !  PowerPad (ZBSMPPP) !  Slim Pad (ZBSMPSP) !  CompactPad Tabletop Version (ZBSMPCP) !  CompactPad Flush Mount Version (ZBSMPCP-F) !  Low Profile Pad (ZBSMPLP) !  Integrated Pad (ZBSMPIP)    © Sensormatic 2002 Equipment RequiredEquipment RequiredEquipment RequiredEquipment Required    •  Controller •  Laptop with minimum Windows 98 SE •  Standard CE RS232 Ultra•Max programming cable •  Hard Tag •  Four DR LE labels minimum InstallationInstallationInstallationInstallation    The controller can be mounted three ways: !  On the countertop !  To the underside of the countertop !  To the sidewall of the counter. Warning! If mounting the controller to the sidewall of a counter, its cable connectors cannot face up. The controller can be mounted, out-of-the-box, to the countertop. If mounted to the underside of the countertop or to the sidewall of the counter, a mounting bracket is required. This bracket contains key slots for easy mounting. Detailed mounting instructions are supplied with the bracket.
Company Confidential SCANMAX PRO INSTALLATION AND SETUP GUIDE (8200-0054-01, REV. 02) 2 of 5 SetupSetupSetupSetup           1.  If supplied, plug the remote cable into the “remote” controller port. 2.  Plug in the antenna cable. 3.  Plug the AC cord into the input male jack.  4.  Turn on the AC power. The rocker switch should be ‘green’ and the status indicator may blink orange until the controller auto-synchronizes. When synchronizing is complete, the status indicator should be solid green. Auto synchronization can take up to ten seconds. Note: If the status indicator is blinking green, then either the deactivation or transmit function is disabled. If the indicator is alternating red/yellow or is solid red, then there is no high voltage available for deactivation. In either case, contact ADT for advice. The complete list of status indications is shown opposite. Controller Status IndicatorsController Status IndicatorsController Status IndicatorsController Status Indicators    Status Indicator on Controller (Note: Red color may appear orange.) Solid Green  Unit ready. Blinking Green  Transmit disabled by key switch or configurator. Blinking Yellow  Controller is in auto-sync. Alternating Red/Yellow  The high voltage circuit is not working. Solid Red  +25V or sync fault.  Mode Indicator on Controller (Use the PROG Button to cycle through the selections below.) Bottom LED On  The controller is set for use with an SR label. Bottom LED Off  The controller is set for use with a DR label. Top LED On  The controller is set for Mag-Safe operation. Top LED Off  The controller is set for routine operation. Both LEDs Blink  Antenna EEPROM fault.  Status Indicators on  Remote Alarm Module (if used) Green On, Red Off  Unit ready. Blinking Green  Transmit disabled by key switch or configurator. Green On, Yellow Blinks  Controller is in auto-sync. Green On, Red Flashing Every 250 ms  The high voltage circuit is not working. One Beep  The controller attempted to deactivate a label. Continuous beep until a hard tag is removed from the field. The controller is in HT test mode.   RemotePort  Antenna PortAC Power Cord AC Power Switch Status Indicator Program Button Mode Indicator
Company Confidential SCANMAX PRO INSTALLATION AND SETUP GUIDE (8200-0054-01, REV. 02) 3 of 5 Advanced Setup and Advanced Setup and Advanced Setup and Advanced Setup and     Adapter ConfigurationAdapter ConfigurationAdapter ConfigurationAdapter Configuration    1.  Plug in the programming cable into the service port of the controller. 2.  Start the ScanMax Pro configurator by clicking on the icon. 3.  Verify settings as follows for your antenna type. Do not change settings at this time. Default Settings Antenna Tx Power Threshold Low Profile Pad  Med 8 (+1)" 20 (+2.5) cm PowerPad Med 7 (+1.5)”  17.5 (+3.75) cm SlimPad Med 6 (+1.5)" 15 (+3.75) cm ScanMax IP  Med  6 (+1.5)" 15 (+3.75) cm CompactPad Med 6 (+1)" 15 (+2.5) cm  4.  Use the threshold setting to adjust the detection height for the checkout environment. Use the detection compensation slide bar to compensate for special mounting such as metal countertops. 5.  Using the EXIT button on the configurator, exit the configurator.   If false deactivating occurs… If false deactivating occurs… If false deactivating occurs… If false deactivating occurs…     If false deactivating occurs, the configuration default values need to be modified as follows:  a.  Plug in the programming cable into the Service port of the controller. b.  Start the ScanMax Pro configurator by clicking on the icon. c.  Click on the RESYNC button. If false deactivation discontinues, go back to step 4; otherwise, continue. d.  Ensuring no label/tag is close to the antenna, reduce Tx POWER one level at a time until the system does not false deactivate (firing without a label/tag present). Write this level down. e.  Set the Tx POWER level one step higher. Note: Maximum detection and deactivation height may be reduced compared with that listed in the table due to ambient noise and mounting locations. Note the new heights. f.  If these steps fail to stop false deactivation, contact Service Planning.    Exit Button Detection Compensation Tx Power
Company Confidential SCANMAX PRO INSTALLATION AND SETUP GUIDE (8200-0054-01, REV. 02) 4 of 5 SpecificationsSpecificationsSpecificationsSpecifications    ElectricalElectricalElectricalElectrical    Primary input.......................... 100-120/200-240 Vac 50-60 Hz ±5% 1.4 Arms maximum  EnvironmentalEnvironmentalEnvironmentalEnvironmental    Operating temperature........... 0 to 40°C (32°–104°F) Non-operating temperature.... –40° to 70°C  (–40° to 158°F) Relative humidity.................... 0 to 90% non-condensing MechanicalMechanicalMechanicalMechanical    Height..................................... 10 CM (3.9 in.) Width...................................... 26.3 cm (10.4 in.) Depth ..................................... 22.1 cm (8.7 in.) Weight.................................... 2.5 kg (5.5 lbs.)   DeclarationsDeclarationsDeclarationsDeclarations    Regulatory CompliaRegulatory CompliaRegulatory CompliaRegulatory Compliancencencence    Emissions...............................47 CFR, Part 15   ENS 300 330  EN 301489  EN61000-3-2  EN61000-3-3  RSS 210 Safety .....................................UL60950   CSA C22.2 No 60 950   EN 60 950 FCC COMPLIANCE: This equipment complies with Part 15 of the FCC rules for intentional radiators and Class A digital devices when installed and used in accordance with the instruction manual. Following these rules provides reasonable protection against harmful interference from equipment operated in a commercial area. This equipment should not be installed in a residential area as it can radiate radio frequency energy that could interfere with radio communications, a situation the user would have to fix at their own expense. EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics Corporation, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition. Other DeclarationsOther DeclarationsOther DeclarationsOther Declarations    WARRANTY DISCLAIMER: Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic Electronics Corporation reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics Corporation to notify any person of such revision or changes. LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States. TRADEMARK NOTICE: ScanMax, Sensormatic, and the Sensormatic logo are trademarks or registered trademarks of Sensormatic Electronics Corporation. Other product names mentioned herein may be trademarks or registered trademarks of other companies. No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics Corporation. MDR 3/02
Company Confidential SCANMAX PRO INSTALLATION AND SETUP GUIDE (8200-0054-01, REV. 02) 5 of 5