UNION COMMUNITY FMD-10 Flush Mount Door Lock User Manual Smart i UserGuide 1 00

UNION COMMUNITY Flush Mount Door Lock Smart i UserGuide 1 00

User Manual

Copyright 2014 Union Community Co., LTD.   FMD10-BLE User Guide  Version eng-1.06
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com  <Revision History>    Version Date Description Firmware Version 1.00 2014-08-06 Initial Release 10.61.00-000.16 1.01 2014-08-07 Changed default values  1.06 2015-10-19 FMD10-BLE changes 20.62.00-000          < Glossary >   Admin, Administrator - As a user who can enter into the terminal menu mode, he can register/modify/delete terminal users and change the operating environment by changing settings. -   If  there  is  no  administrator for  a  terminal, anyone can  change  the  settings, so  it  is recommended to register at least one administrator. -   Caution is required with registration and operation because an administrator has the right to change critical environmental settings of the fingerprint recognition unit.   Authentication Method - Various  Kinds  of  authentication  including  FP  (fingerprint)  authentication,  RF  (Card) authentication, or a combination of these methods. Ex) Card or FP:    Card or fingerprint is used for authentication.   Bell Button - Used to activate a bell/device/door phone that is externally connected to the device.
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com  Table of Contents <Revision History> ................................................................................................... 2 < Glossary > .............................................................................................................. 2 Table of Contents ..................................................................................................... 3 1. Read Before Using ............................................................................................... 4 1.1. Safety precautions ...................................................................................... 4 1.2. Specification ................................................................................................ 5 1.3. Device description ....................................................................................... 6 1.4. LED operation .............................................................................................. 6 1.5. Door Bell Key Operation ............................................................................. 7 1.6. Buzzer sound during operation .................................................................. 7 1.7. Correct fingerprint registration and input methods ................................. 7 2. Introduction .......................................................................................................... 9 2.1. Description ................................................................................................... 9 2.2. Features ....................................................................................................... 9 2.2. Configuration ............................................................................................. 10 2.2.1. Standalone Configuration ................................................................... 10 3. Environment Settings ........................................................................................ 11 3.1. Parameters ................................................................................................. 11 4. How to use the terminal ..................................................................................... 13 4.2. Authentication ........................................................................................... 13 4.2.1. Fingerprint authentication ................................................................... 13 4.2.2. Card authentication ............................................................................ 13 4.2.3. Successful Authentication ................................................................... 13 4.2.4. Door Bell Operation ............................................................................ 13
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com  1. Read Before Using  1.1. Safety precautions    Warning Handling with wet hands or   allowing liquid to flow into it is not advised.                         -> it may cause an electric shock or damage.  Do not place a fire source near the unit.  It may cause a fire.   Do not disassemble, repair, or modify the unit. -> It  may cause an electric shock, fire or damage.  Keep  out  of  reach  of children.                                         ->  It  may  cause  an accident or damage.  - If the above warnings are ignored, it may result in death or serious injury.    Cautions Keep  away  from  direct sunlight                                     ->  It  may  cause deformation  or  color change.  Avoid  high  humidity  or dust ->  The  unit  may  be damaged.  Avoid  using  water, benzene, thinner, or alcohol for cleaning -> It  may cause  an electric shock or fire.  Do  not  place  a  magnet close to the unit. ->  The  unit  may  break down or malfunction.  Do  not  contaminate  the fingerprint input area. ->  Fingerprints  may  not  be well recognized.  Avoid  using  insecticides or flammable sprays near the unit. ->  It  may  result  in deformation  or  color change.  Avoid  impacts  or  using sharp objects on the unit. ->  The  unit  may  be damaged and broken.  Avoid severe temperature changes. ->  The  unit  may  be broken.  - If the above cautions are ignored, it may result in property loss or human injury.  ※ Under no circumstances will Union Community be responsible for accidents or damages caused by inappropriate use of the product caused by not referring to the user manual.
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com 1.2. Specification  ITEM SPEC REMARK CPU 32Bit RISC CPU(400MHz)  RTC CPU RTC / Lithium Battery Time/Date for Logs Bell Key Capacitive Touch Sensor   Activate Bell Output LED 3 Colors (Red, Green, Blue)  Buzzer Audible feedback buzzer  MEMORY 64M SDRAM  4M NOR Flash 1,000 User (1,000 Finger)  Fingerprint Sensor Optical    Authentication Speed <1 sec.  Scan Area / Resolution 13.2 * 15.2 mm / 500 DPI 260*300  FRR / FAR 0.1% / 0.001%  Temperature / Humidity   Operating Current Standby: 80mA Maximum: 250mA  AC / DC Adapter INPUT : Universal AC 100 ~ 250V  OUTPUT : DC 12V  UL, CSA, CE Approved  Communication Port Bluetooth: Bluetooth v2.1 + EDR Class 2 Output Power B-UNIS Smartphone application   RS-485 BLC015/LC010 Wiegand Out Standard 26/34 bit Wiegand Lock Lock Normally Closed/Open Door Lock Monitoring M0, M1 Inputs Door monitoring Inside Open IO Exit Button Input Bell Output Bell A/B Max Current = 60mA Door phone/bell output Card Reader 125KHz RF (optional) 13.56MHz SC  SIZE 72mm * 111mm * 41.4mm
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com    1.3. Device description      1.4. LED operation  ● Failure Red Light off : Normal Light on : When authentication is failed ● Success Green Light on: Card or Fingerprint successful authentication. Will turn on for the door open period duration. ● Status Blue Flickering : Bluetooth connection status ( if enabled) Light on: When “LED always on”  is  set  in  the terminal       settings.            3 Color LED   (Red, Green, Blue) Fingerprint Sensor   Card input area   Capacitive Touch Bell Button
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com 1.5. Door Bell Key Operation  Normal Operation   When  pressed  beep  sound  is  emitted  and  the  bell  output  will activate ( Door Bell Operation) Initialize Parameters 1)  Apply Power     2)    Within 1 second press and hold the bell key for 2 seconds BLE Register Mode   When  registering  the  device  with  the  mobile  application  press and hold the Door Bell Key for 5 seconds.    1.6. Buzzer sound during operation  “beep” Pressing  Bell button  or  a reading a card When a button is pressed or a card is being read When fingerprint input is completed, allowing the user to remove his fingerprint “beep beep” Failed Authentication failed or wrong user input “beep,beep beep” Successful Authentication  successful  or  settings  for  the  current user are completed.   1.7. Correct fingerprint registration and input methods    Correct fingerprint registration methods  Place your index finger on the window just as you do with a finger stamp. Finger tip touching is not an appropriate registration or input method. Make sure the center of your finger touches the window.      Use your index finger.  The index finger guarantees an accurate and stable fingerprint input.        *    Check if your fingerprint is unclear or damaged.               It is difficult to recognize fingerprints on dry, wet, unclear, or injured fingers.               Use another finger in this case.
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com      Cautions about fingerprint condition  Depending on  the user’s fingerprint  condition, some fingerprints may  not  be  used  or may cause an inconvenience.    If the fingerprint is damaged or very unclear, then it cannot be recognized. Please use a password instead in this case.    When a finger is dry, breathe on the finger for smooth operation.    For kids, it may be tricky or impossible to use the unit because their fingerprints are too small or very unclear. It is recommended to register their fingerprints every six months.    For the elderly, it may not be possible to register their fingerprints if there are too many fine lines on the fingerprints.    It is recommended that you register more than 2 fingerprints.
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com  2. Introduction  2.1. Description  FMD10 is a flush mount access control device. It can be used in small/medium business applications  or  residential  access  control.  FMD10  will  provide  access  into  a  secured  area using a registered fingerprint or card. A door bell feature is available for connecting the FMD10 to a door phone or door bell for visitors.   FMD10 communicates using Bluetooth Low Energy (BLE) Technology to the UNIS-B Plus or imKey mobile application for mobile key access and/or administrative functions.  2.2. Features   Bluetooth v4.0 Communication  -  Simple setup using UNIS-B Plus smartphone application   Log management   Firmware upgrade   User Management   Optical Fingerprint Sensor Auto Sensing - Simple authentication process without any key input Live  Finger  Detection  (LFD)  –  Programmable  LFD  level  for  detecting  real/fake fingerprints.   Card Reader   Smart card reader (standard) or optional 125KHZ RF reader.   Door Bell -  Capacitive  touch  key  for  activating  an  externally  connected  door  phone/bell  for visitors.
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com  2.2. Configuration   2.2.1. Standalone Configuration          Please see the B-UNIS SmartApp User Guide for setup and connection information  Establish Bluetooth connection to B-UNIS smartphone application - B-UNIS Password: 9999 - Basic setup when released from a factory NOTE:  If  the  B-UNIS  Password  is  lost  and  you  cannot  connect  to  the  FMD10  you  should factory initialize the device see 1.5. Door Bell Key Operation      ● FMD10 B-UNIS
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com  3. Environment Settings  3.1. Parameters  Setup parameters are set from the B-UNIS Smartphone application:  Terminal/Device Name: 1-30 characters This is the FMD10 name for identifying the device from the Bluetooth   Default: FMD10_99999999  Buzzer Sound: ON/OFF This is to control the buzzer output   Default: ON  Bluetooth Status LED: Enable/Disable If enabled the blue LED will flicker when successfully connected to the B-UNIS application   Default: ON  Blue LED: Enable/Disable If enabled the blue LED will always be on and if connected to the B-UNIS application the blue LED will turn off. If Bluetooth status LED is enabled, the blue LED will flicker when connected.   Default: ON  LFD Level: Off/Low/Medium/High Live Finger Detection for fingerprint detection. This feature can be used for higher security applications when the  user would like to protect against fake fingerprints. If the level is too high some registered users may take longer for fingerprint authentication. Default: Off  Logon Password: 1-16 characters This password is used for logging into the B-UNIS application via the smartphone. Default: 9999  Door Status #1: Disabled/Normally Open/Normally Closed If a monitoring device (door lock) is connected to the M0 input on the FMD10, this value should be set according to the external device settings. (NO or NC) Default: Disabled  Door Status #2: Disabled/Normally Open/Normally Closed/Fire Normally Open/Fire Normally Closed If a monitoring device is connected to the M1 input on the FMD10, this value should be set according to the external device settings, if connected to an external fire system and a fire is detected, the FMD10 will open the door. (NO or NC).   Default: Disabled  Door Open Time: 1-60 seconds This is the lock activation period. If a lock is connected to the lock output, the lock will open for this period. Default: 3  Bell Touch Key: 100-5000ms (0=disabled) If the bell key is used for a door bell, this is the period in which the bell button must be pressed for. If 0 is set the bell touch key is disabled. Default: 5000ms  Bell Activation Period: 0-60 seconds If the Bell touch key is pressed, this is the period in which the bell output will activate. 0 = disabled. Default: 1 second
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com  Card Format:Hexa Reversed, Hexa Normal, Decimal, Decimal_2 When a card is scanned this setting determines the encoding format of the card. Default: Hexa Reversed  Wiegand Output: Disabled/26 bit/34 bit If the FMD10 is connected to an external controller using the Wiegand outputs, this is the format of the User ID sent to the external controller using wiegand. Note: Only a successful authentication will send the user id via wiegand Default: Disabled  Wiegand SiteCode: 0-255 decimal If wiegand output is enabled, this is the 3 digit ID code sent before the user id on the wiegand output ( i.e 2551234) this is 255 and user ID=1234. Default: 0   Lock Function:      LOCAL= Set this option if connecting your lock device on the FMD10 device. (Default setting) BLC015/LC010 = Set this option if connecting your lock to the LC010 or BLC015.     485ID  =  (Unsupported, Do  not use)  Set  this  option,  and then  set  ID  from  0-7 if  using  the  485A/B connected to an external controller.    Note: For all devices externally connected to the FMD10 (locks, monitoring, wiegand, etc). Please see the FMD10 Installation and Wiring Diagram. When setting for BLC015/LC010, the lock output and the Inside Open on the FMD10 will not operate. In this case the lock should only be connected to the BLC015/LC010.   1:N Level: valid entries from 3-9   This option represents the security level between the captured fingerprint (from the sensor window), and the fingerprints stored in the terminal. This level represents the terminal level, not individual users. Possible  values  are from 3-9.The  higher  the  value,  the  higher  the  security level, which means  more comparisons are done on the fingerprint data. If user’s fingerprints are failing during authentication you should lower this value.    1:1 Level: valid entries from 1-9  This option represents the matching security level in the device between the captured fingerprint (from the sensor window) and the stored fingerprint in the database for that user. This value is used when the card & fingerprint authentication type is used. Instead of comparing the captured fingerprint with all the database fingerprints, only the user’s fingerprint is compared. Possible values are from 1-9. The higher the  value  level,  the  higher  the  security  level;  however  authentication  matching  may  fail  since  more matching is done on the fingerprint data.
FMD10 User Guide Seoul, Songpa-gu, Bangi-dong 44-3 Hyundai Topics Bldg 9F (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.virditech.com 4. How to use the terminal   4.2. Authentication  4.2.1. Fingerprint authentication      When you place your finger on the fingerprint sensor, the light of the sensor will turn on and the buzzer will beep indicating a successful fingerprint scan. You should not remove your finger  until the  beep is heard.  If  there are no  registered users in the  FMD10, the fingerprint light will not turn on.   4.2.2. Card authentication  Swipe a card on the card input area.     4.2.3. Successful Authentication  When a registered card or fingerprint is detected the FMD10 can activate a lock output for a programmable period of time to open the door. The beeper will indicate a successful entry and the LED will light up green color for the door open period.   4.2.4. Door Bell Operation  If the bell  button  is pressed for the bell touch period, the  bell output will activate for a programmable period of time (Bell Activation Period). The device will annunciate a ‘ding-dong’ sound and the LED will flash. If a fingerprint or card is used during the Bell Activation Period, the bell will immediately turn off.   If a fingerprint or card is used the bell button will not accept any button presses until the door open duration has expired
FCC Information   This  device  complies  with  part  15  of  the  FCC  Results.  Operation  is  subject  to  the following two conditions : (1) This Device may not cause harmful interface, and   (2) This device must accept any interference received, including interference that    may cause undesired operation. Note: This  equipment has been tested and found to comply with the  limits for CLASS  B digital device,  pursuant  to  Part  15  of  FCC  Rules.  These  limits  are  designed  to  provide  reasonable protection  against  harmful  interference  when  the  equipment  is  operated  in  a  commercial environment This equipment generates, uses and can radiate radio frequency energy and, if not installed and  used in  accordance with the instructions, may  cause harmful interference to  radio communications.  However,  there is  no  guarantee  that  interference  will  not  occur  in  a  particular installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or  television  reception, which  can  be  determined  by  turning  the  equipment  off and  on,  the  user  is  encouraged  to  try correct the interference by one or more of the following measures:   1.1. Reorient or relocate the receiving antenna. 1.2. Increase the separation between the equipment and receiver. 1.3.  Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  receiver  is connected. 1.4. Consult the dealer or experienced radio/TV technician for help. WARNING Changes  or  modifications  not  expressly  approved  by  the  manufacturer  could  void  the user’s authority to operate the equipment. Contains FCC ID: 2AEEY-PBLN51822M

Navigation menu