UNION COMMUNITY KL-100X Digital Door Lock User Manual

UNION COMMUNITY Digital Door Lock

User Manual

      Quick  MANUAL    Keyless Key (KL-100)
Instruction Manual  Precautions for Safety  <Warning> This precaution must be read to protect the users and to prevent any property loss or inconvenience. Please read it carefully for proper use.   Do not install or repair this product by yourself.  Do not install where the space between the door and the door frame is less than 5mm.  Be careful not to expose your PIN code, and please change it regularly.  Do not use the product with wet hands. Be aware of liquid such as water or drinks permeating into the product.  Do not press the buttons of the keypad with excessive force or use sharp objects.  Please confirm that the door is completely locked before leaving.  Please check the polarity (+/-) of the battery before inserting. Please be aware as fluid flowing or battery rupture may occur if the polarity of the battery is reversed.  Change all the batteries at once when they go dead. Do not confuse new batteries with the old ones.  Do not use water, benzene, or alcohol to clean the product. Only use dry clothes.  Please replace the batteries within a week after the initial low-battery alarm.
Identification of Product   Out-Body                     Card Reader - Card authentication Bluetooth 4.0[BLE] - i-Key authentication - d-Key authentication Mechanical Key   Keypad - PIN Code authentication
In-Body                         DIP S/W Tact S/W    A Fixing Screw    Battery Manual lever Tact S/W    B ● TACT S/W‘A’ /  ‘B’  & DIP S/W (On/Off Position)   1. TACT  ‘A’ : (Press Long) i-Key Doorlock Registration. (Press Short) Password Change Mode   2. TACT  ‘B’ : (Press Long) Card Registraion. (Press short) d-Key Registration & Doorlock Setting.     3. DIP Switch #1 (Left / Right Door Select) DIP Switch #2 (Buzzer Mute On/Off) DIP Switch #3 (Easy-Lock On/Off)   DIP Switch #4 (Reserved)
Using PIN code (Password) Using PIN code to control the door lock PIN code is used for User code and Guest code. Initial PIN code and Factory Reset PIN code is “0000”  <USER PIN code> Registration ① Open the battery cover of In-Body ② Press tact S/W ‘A’ shortly to activate the keypad of Out-Body ③ Press the current PIN code (initial code is 0000) and # ④ Press new PIN code and # (alarm) ⑤ Press the new PIN code once again and press # (alarm) ⑥ The keypad of Out-Body will go off ⑦ PIN code is registered  How to Use ① Touch the keypad or the keybox of Out-Body ② Two random numbers and ‘*’ / ‘#’ will appear ③ Press the two numbers regardless of order ④ The keypad will be activated ⑤ Press the registered PIN code and press # (Door will open)  <Guest PIN code> Registration ① Touch the keypad or the keybox ② Two random numbers and ‘*’ / ‘#’ will appear ③ Press ‘#’ for two seconds, and the keypad will be activated   ④ Press the registered PIN code and press # ⑤ Press the Guest PIN code (4 digits) of your choice and press # ⑥ Guess PIN code is registered successfully (alarm)   (In order to delete the Guest PIN code, proceed until ③ and wait for 5 seconds)
How to Use ① Touch the keypad or the keybox of Out-Body ② Two random numbers and ‘*’ / ‘#’ will appear   ③ Press the two numbers regardless of order ④ The keypad will be activated   ⑤ Press the registered Guest PIN code and press # (Door will open)   (Guest PIN code is valid only for single entry, and will be deleted after use.)  Using Card / Key Tag The door lock  can be controlled by  cards and key tags  which has RF function. Maximum of 10 cards or key tags can be registered. * Caution * After  entering  the  registration  mode  and  register  new  cards  or  key  tags,  previously  registered cards or key tags will be deleted. Therefore, please register all at once.  Registration ① Open the battery cover of In-Body ② Press tact S/W ‘B’ for 2 seconds and ‘C’ will appear on the keypad ③ Hold the card or key tag you want to register near the surface of the keypad ④ Alarm will ring as the card or key tag is registered successfully ⑤ Hold more cards or key tags you want to register near the surface of the keypad one by one. ⑥ The registration mode will be deactivated if no card or key tag is registered within 5 seconds   (In order to delete the registered cards and key tags, enter the registration mode and register new card or key tag, or Factory Reset the door lock.)  How to Use ① Touch the keypad or the keybox of Out-Body ② Two random numbers and ‘*’ / ‘#’ will appear   ③ Hold the card or key tag near the surface of the keypad (door will open)
Using Smartphone (d-Key) Controlling the door lock with Smartphone that has Bluetooth function Install  Keyless  key  App  on  your  Smartphone  and  follow  the  procedures  below  to  register. Maximum of 10 Smartphones can be registered. Registration ① Open the battery cover of In-Body ② Press tact S/W ‘B’ shortly and green LED of the keybox will be on ③ Run the Keyless key App on your Smartphone (enter the menu mode) ④ Enter the PIN code registered in your door lock ⑤ Press d-Key Button at the bottom of the screen ⑥ Press Register Button (Alarm) ⑦ After the registration is done, it will turn to standby mode. Repeat from  ②  to add more devices.   (In order to delete, follow  the procedures until 2.4.1-⑤  and press Delete-All Button at the bottom, or Factory Reset the door lock to delete all the d-Keys) How to Use 1   ① Touch the keypad or the keybox of Out-Body ② Two random numbers and ‘*’ / ‘#’ will appear ③ When the green LED of the keybox turn on, activate the App on your smartphone and press Open Button. (Door will open) How to Use 2   ① Touch the keypad or the keybox of Out-Body ② Two random numbers and ‘*’ / ‘#’ will appear When the green LED of the keybox turn on, shake or swing the Smartphone, which the screen is off. (Door will open)
Additional Function    Factory Reset  Every information will be  deleted  and turn  to  default  settings, except the  Serial  Number of the product. ① Open the battery cover ② Press both tact S/W ‘A’ and ‘B’ together for 5 seconds. ③ Alarm will ring and resetting procedure will be proceeded ④ All the functions User has registered will be deleted. (PIN code will be set to 0000)   LED Status  ① Red : Malfunction / Authentication Failure / Duplicate Registration / Rectification / Force Entry ② Green : Authentication Succeeded / Registration Standby / Authentication Standby / Unlocked ③ Orange : Low-Battery Warning   Battery Replacement Low-Battery alarm will ring - It is time to replace the batteries if the orange LED turn on with alarm when you open the door with PIN code or RFID card.  Replacing the Battery - Replace all the old batteries with new ones within a week after the initial warning alarm.
Caution Duration of the battery differs depending on its brand, date of manufacture, and service environment (Four 1.5V AA Alkaline Batteries, assuming that it is used 10 times a day, lasts approximately 10 months.) As fluids may flow from the batteries and damage the product, please check it regularly. ( Every 6 months)    Product Specification  Item Contents CPU ATSAM4LS4(M4) Memory 2Mbyte Touch key 3*4 Key (Capacity type) RF Tag 13.56Mhz Bluetooth Bluetooth 4.0 [BLE] Authentication Type RF Card. Mobile key. Password Mechanical Key Lock Deadbolt(UL) Environment -20~60 ℃  / < RH 90% Certificate CE, FCC,IP54 Dimension Inbody : 83(W) x 164.5(L) x 37(D) mm outbody : 85.3(W) x 183.8(L) x 33.6(D) mm Power Battery [AA Type 4EA (DC+6V)]
FCC Information   This  device  complies  with  part  15  of  the  FCC  Results.  Operation  is  subject  to  the following two conditions : (1) This Device may not cause harmful interface, and   (2) This device must accept any interference received, including interference that    may cause undesired operation. Note: This equipment has been tested and found to comply  with the limits for CLASS B digital device,  pursuant  to  Part  15  of  FCC  Rules.  These  limits  are  designed  to  provide  reasonable protection  against  harmful  interference  when  the  equipment  is  operated  in  a  commercial environment This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with  the  instructions,  may  cause  harmful  interference  to radio communications.  However,  there  is no guarantee that  interference will not  occur  in  a  particular installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or  television  reception, which  can  be  determined  by  turning  the  equipment  off  and  on, the  user  is encouraged  to  try correct the interference by one or more of the following measures:   1.1. Reorient or relocate the receiving antenna. 1.2. Increase the separation between the equipment and receiver. 1.3.  Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  receiver  is connected. 1.4. Consult the dealer or experienced radio/TV technician for help. WARNING Changes  or  modifications  not  expressly  approved  by  the  manufacturer  could  void  the user’s authority to operate the equipment. Contains FCC ID: 2AEEY-PBLN51822M