UNION COMMUNITY XID-300 Access Controller User Manual
UNION COMMUNITY Access Controller Users Manual
Users Manual
XID-300 User Manual Version Eng-0.01 Copyright ⓒ LG CNS Copyright ⓒ 2011 LG CNS 2 Safezone XID-300 < Contents > 1. Before Use ................................................................................................................................................ 3 1.1. Safety Precautions....................................................................................................................................................... 3 1.2. Terminal Description .................................................................................................................................................. 5 1.3. Screen Description (During Operation).............................................................................................................. 5 1.3.1 Icons Shown During Operation ................................................................................................................. 6 1.3.2 Message Shown During Operation ......................................................................................................... 6 1.3.3 LED Signal Shown During Operation ...................................................................................................... 7 1.3.4 Keys Used During Operation...................................................................................................................... 7 1.3.5 Voices Used During Operation .................................................................................................................. 7 1.3.6 Buzzer Sounds Used During Operation ................................................................................................. 8 1.4. How to unplugged terminal power supply safely ......................................................................................... 8 2. Product Introduction .............................................................................................................................. 9 2.1. Features ........................................................................................................................................................................... 9 2.2. Block diagram ............................................................................................................................................................. 10 2.3. Specification ................................................................................................................................................................ 11 3. Environment Settings ........................................................................................................................... 12 3.1. Enter the Menu. ................................................................................................................................................12 3.1.1 When you forget password ......................................................................................................................12 3.1.2 Admin main menu ........................................................................................................................................12 3.2. Menu Configuration .................................................................................................................................................13 3.2.1 Network ............................................................................................................................................................. 14 3.2.1.1 Terminal IP and Server IP setting ........................................................................................................ 14 3.3.1 System Setting ................................................................................................................................................15 3.3.1.1 Language .......................................................................................................................................................15 3.3.1.2 Volume ........................................................................................................................................................... 15 3.3.1.3 Initialization .................................................................................................................................................. 16 3.3.1.4 Door Control ................................................................................................................................................17 3.3.1.5 Password ........................................................................................................................................................17 3.3.1.6 Background image .................................................................................................................................... 18 3.4.1 Application ....................................................................................................................................................... 18 3.5.1 Terminal Info ................................................................................................................................................... 19 3.6.1 Option ................................................................................................................................................................ 19 Copyright ⓒ 2011 LG CNS 3 Safezone XID-300 1. Before Use 1.1. Safety Precautions z Warning Do not handle the unit with wet hands and do not allow liquid to flow into, or on, it. -> It may cause an Do not place a fire source near the unit. -> It may cause a fire. electric shock or damage. Do not disassemble, repair, Keep out of children’s or modify the unit. reach. -> It may cause an electric -> shock, fire or damage. accident or damage. It may cause an - If the above warnings are ignored, it may result in death or serious injury. z Cautions Keep away from direct sunlight Avoid high humidity or -> It may cause mal- dust function, deformation or ->It may cause the unit change the colour of the to malfunction. unit. Avoid using water, benzene, thinner, or Do not place a magnet alcohol for cleaning the near the unit. unit. -> The unit may break -> It may cause an electric down or malfunction. shock or fire. Copyright ⓒ 2011 LG CNS 4 Safezone XID-300 Avoid using insecticides Avoid getting the fingerprint input area dirty. ->It may prevent the unit from recognising the fingerprint. or flammable sprays near the unit. -> It may result in the deformation or change the colour of the unit. Avoid installing the unit Avoid impact or using in a place where sharp objects on the unit. temperature changes -> The unit may get severely. damaged and broken. It may cause the unit to malfunction. - If the above cautions are ignored, it may result in property damage or human injury. ※ Under no circumstances will Union Community be responsible for accidents or damages caused by inappropriate use of the product and neglect of the precautions stated in the user guide. Copyright ⓒ 2011 LG CNS 5 Safezone XID-300 1.2. Terminal Description State Display LED LCD Card Input Area Touch Key Normally, the figures are invisible as the LED is off. LED turns on and the figures illuminate when the user lightly 1.3. Screen Description (During Operation) Door State Connection with Server Current Time Copyright ⓒ 2011 LG CNS 6 Safezone XID-300 1.3.1 Icons Shown During Operation Door Status : Door status is unknown. : Door is closed. : Door is open. Connection Server of : LAN cable is connected, but not yet to the server. : Connected with the server. 1.3.2 Message Shown During Operation When authentication is successful. When authentication has failed. - As any unregistered card is input. When authentication has failed. - As card is registered at BL. Copyright ⓒ 2011 LG CNS 7 Safezone XID-300 When authentication has failed. - As card is expired. When the lid of the terminal is opened 1.3.3 LED Signal Shown During Operation Green When authentication has failed, when the lid of the terminal is opened Red When authentication is successful. 1.3.4 Keys Used During Operation [0] ~[9] - Keys used for numeric input. [F1] - When put IP, it is used as dot (.) [F4(Í)] - When you put numbers, it is used as Delete. - Use the [F4 (←)] key to cancel input during setting [ENT] - Used for accessing the menu when pressed on the initial screen - Used for moving to set next value in main menu. - Used to apply the configuration to the current screen in menu mode and then exiting to the parent menu. 1.3.5 Voices Used During Operation Type of Operation Voice When authentication is successful Thank you. Copyright ⓒ 2011 LG CNS 8 Safezone XID-300 When authentication has failed. This card is not registered. Please try again. When terminal is Initialized Terminal is initializing 1.3.6 Buzzer Sounds Used During Operation Beep When the key is pressed or card is read Be peep when the lid of the terminal is opened 1.4. How to unplugged terminal power supply safely When you put [ENT] for 3seconds, LED of keypad is off and then on with Beep sound. After taking off your finger, the following left screen appears. If you press [F1] 4times and [ENT], the following right screen appears. If you press [ENT], terminal is restart safely. At that time, you make it disconnect. Copyright ⓒ 2011 LG CNS 9 Safezone XID-300 2. Product Introduction 2.1. Features • Slim and polished design - Easy to install as it is designed as a standalone type; Slim and elegant design using Colour LCD and Touch Keys • Change the LCD background image and voice using USB. - Provides a variety of information messages via the colour LCD screen and voices. You can download background images and voice messages suing USB. Also, the built-in LCD Screen Backlight and Touch Key LED’s allow the screen to be read and keys to be operated in dark conditions. • Designed to IP65 rainproof specification – Outdoor installation is possible. • Access Management System Using a Network (LAN) - Communication is carried out between the fingerprint recognition device and authentication server using TCP/IP protocol, and allows for easy expansion as it can be applied to the network as is. 10/100 Mbps Auto Detection ensures high-speed operation. Enables easy management and monitoring via the network. • Provides a Diverse and Flexible Access Management - Provides a perfect control function by granting entrance/access rights by user group. Copyright ⓒ 2011 LG CNS 10 Safezone XID-300 2.2. Block diagram Copyright ⓒ 2011 LG CNS 11 Safezone XID-300 2.3. Specification Item Specification CPU 32Bit RISC CPU(400MHz) LCD 2.8” TFT Color (320*2400 Touch Key 15Key (0~9, F1~F4,Enter) Memory 32M SDRAM Remarks 16M NOR FLASH 128M NAND FLASH Temperature/ -20 ~ 50 / Humidity Lower than 90% RH AC / DC Adapter INPUT : Universal AC100 ~ 250V Output OUTPUT : DC 12V Communication Port RS485 Card Reader 13.56Mhz Smart Card Size 88.0mm * 175.0mm * 43.4mm Copyright ⓒ 2011 LG CNS Lock Controller Communication 12 Safezone XID-300 3. Environment Settings 3.1. Enter the Menu. When you put [ENT] for 3seconds, LED of keypad is off and then on with Beep sound. After taking off your finger, the following screen appears. The initial password is 2345. 3.1.1 When you forget password You make your terminal to be disconnect. Door state is changed to gray . (You can’t change password while using terminal.) Make /xid30/pw folder in USB and connect USB and terminal. After 10 seconds, put [F1],[1],[F2],[2] and [ENT] at admin main menu. If you do so, initial password is changed. 3.1.2 Admin main menu Copyright ⓒ 2011 LG CNS 13 Safezone XID-300 3.2. Menu Configuration 1. Network 1. Terminal IP Terminal IP Gateway Subnet mask 2. Server IP Server IP Server PORT 2. System 1. Language Korean English 2. Volume Control 1. Voice Volume 2. Beeper Volume 3. Initialize 1. Setting Initialization 2. Data Initialization 3. Terminal Initialization 4. Door Control 1. Open duration 2. Door setting 5. Password change 6. Background change 3. Application - Access, TNA, Meal Attendance, fire 4. Information - Door sate Open / Close - Version 5. Option 1. Lamp Yes or No 2. Sensor Yes or No 3. Case Tamper Audible ON or OFF 4. SAM use Yes or No 5. Terminal IN/OUT setting IN or OUT Copyright ⓒ 2011 LG CNS 14 Safezone XID-300 3.2.1 Network - If pressing [1] at Admin main menu, the following screen appears 3.2.1.1 Terminal IP and Server IP setting - If you want to change it, press [1] and select <1. Terminal IP>. When you set IP, [F1] is for “.”(dot) The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. - After pressing [2] and select <2.Sever IP>, you can change it same as <1. Terminal IP>. Copyright ⓒ 2011 LG CNS 15 Safezone XID-300 3.3.1 System Setting - Put [2] at a main menu, and the following screen appears 3.3.1.1 Language - Selete <1. Language> as putting [1]. You can change what you want as putting [1]or [2]. The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. 3.3.1.2 Volume - You press [1] and select <2. Volume>. You can change what you want pressing [0] ~ [5]. The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. If you select that volume is 0, sound or beep sound is not output. Copyright ⓒ 2011 LG CNS 16 Safezone XID-300 3.3.1.3 Initialization - If you want to initialize what you set, press [1]. If you want to delete data, press [2]. If you want to initialize terminal, press [3] - When you press key you want, the following screens appear. If you want to initialize, press [ENT]. If you want to cancel it, press [F4Å]. If you select Initialization, terminal is reset after initializing. - Setting initialization initializes all data of terminal without MAC address. However, it doesn’t initialize files and logs related with authorization. - Data initialization initializes files and logs related with authorization. Copyright ⓒ 2011 LG CNS 17 Safezone XID-300 - Terminal initialization initializes the whole of terminal. 3.3.1.4 Door Control - Designates the time the door is opened and closed again when authentication is successful. Minimum value is 1 sec and maximum value is 9sec. - <1. Door open> is for that door opens and closes one time. <2. Door open by force> is for that door is always opened. <3. Door open clear> is for that <2> is made to close. - The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. 3.3.1.5 Password -It’s for changing password. When you set password, you can set 4~8 digit using numbers 0 to 9. The initial password is 2345. Copyright ⓒ 2011 LG CNS 18 Safezone XID-300 3.3.1.6 Background image - It’s for changing background image. You can select it you want using [1],[2]. The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. 3.4.1 Application - If pressing [3] at admin main menu, the following screen appears. - You can select application type pressing number you want. The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. The initial value is attendance as 1. Copyright ⓒ 2011 LG CNS 20 Safezone XID-300 Copyright ⓒ 2011 LG CNS 19 Safezone XID-300 3.5.1 Terminal Info - If you press [4] at Admin main menu, the following screen appears. - You can check terminal version and Door open state from Terminal Info. 3.6.1 Option - You can see the following screen appears if pressing [5]. - Lamp (Yes or No) : If setting that Lamp is yes and Look Controller is connected with it, when authentication is successful, blue of lamp light is on and When authentication is fail, red of lamp is on. - External sensor (Yes or No) : If you set external sensor us Yes and Lock Controller is connected with it, terminal can detect value of external sensor. - Case Tamper Audible (ON or OFF) : When you set Case Tamper Audible is ON, If bracket connected with terminal is disconnected, warning sound or message box appears. - SAM authorization setting (Yes or No) : If you set SAM authorization setting is YES, when authentication is only successful using card, door opens. - IN/OUT setting(IN or OUT) : If you connect Lock Controller with two XID terminals, one terminal is set as IN and the other one is set OUT. Copyright ⓒ 2011 LG CNS TDK - EMC Components - Part No: ZCAT1730-0730A Characteristics Page 1 of 1 Close Window EMC Components Clamp Filters (Ferrite Core with Case) Part Number : ZCAT1730-0730A Product Name : Clamp Filters TDK Series Name : ZCAT Series Application : Personal computers, word processors, monitors, hard disk drives, digital telephones, audio devices, electronic musical instruments, video games, copiers and facsimiles. Function : A type means Cable fixed type( hold the cable to secure it with the main body).Ferrite core provides excellent absorption of highfrequency EMC.Highly effective as countermeasure against common mode EMC without adverse effect on signal quality.Large core size prevents saturation during large signal surges. Description : Unique plastic case ensures simple, convenient installation and includes a self-holding mechanism to prevent slippage on cables. Submit Sample Request < Prev | Open PDF file | Next > Check Distributor Inventory Print Page Download Adobe PDF Viewer Additional Search Tools: Application Catalog SEAT Property Name Product Lifecycle Stage TVCL Tech Notes Property Description Production Part Number Replacement No Data Available. Surface Mount No Lead (Pb) Free Yes Body Length (L) Nom 30 mm Outside Diameter Nom Nom 16.5 mm Inside Diameter Nom Nom 7 mm Body Height (T) Nom No Data Available. Cable Diameter 4 to 7 mm Cable Type Round/Oval Cable Impedance Min 40 Ohm Frequency of Impedance Nom 10 MHz Category Temperature Range CCV Min -40 Cel Max 85 Cel Storage Temperature Range Min -40 Cel Max 85 Cel Packing Box Minumum Package Qty Nom 840 Pcs Minimum Order Qty Nom 840 Pcs Weight Nom 12 g Disclaimer: This information is to be used for reference purposes only and is subject to change by TDK without notice. It reflects an overview of the product characteristics/performance for the particular part number. For product specification information, please refer to TDK's general product specification. Please note that this standard part is not designed or warranted to meet any specifications of any intermediate or end user different from or in addition to the specifications set fort in TDK's general product specification. Note also that this standard part has not been specially designed or manufactured for, nor is it intended or warranted for use in , or permitted to be resold for, specialized applications such as aviation, medical, and/or governmental/military applications (collectively, "Excluded Applications"). © TDK U.S.A. Corporation 2009. » Privacy Statement » Site Map TDK Logo is a trademark or registered trademark of TDK Corporation. http://www.tdk.com/s_details.php?class_code=TJA105&item_roots_key=ZCAT1730... 2009-12-04
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2011:10:14 14:35:06+09:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2011:10:24 10:09:52+09:00 Metadata Date : 2011:10:24 10:09:52+09:00 Format : application/pdf Creator : Administrator Title : Microsoft Word - XID300_매뉴얼_20111013_영문 Document ID : uuid:76be88e6-db73-4fa9-b6e9-1e4e992e50cb Instance ID : uuid:baa0561b-c2ee-4a99-9429-f387d4e1341d Has XFA : No Page Count : 23 Author : AdministratorEXIF Metadata provided by EXIF.tools