UTC Fire and Security Americas 772-DWS Door Window Sensor User Manual

UTC Fire & Security Americas Corporation, Inc. Door Window Sensor

User Manual

1Door/Window & Long Life Door/Window SensorsITI Part Nos. 60-362 & 60-641Document Number: 466-1022 Rev. D PRELIMINARYOctober 20008867g01a.ds4Product SummaryThe Door/Window Sensor (60-362) and Long Life Door/Window Sensor (60-641) can be installed on doors, win-dows, or virtually anything that opens and closes. During normal operation, the sensors transmit open (TRIP) and close (RESTORE) signals to the panel. The sensors also send a supervisory signal to the panel every 64 minutes.Sensors transmit open and close signals to the panel when a magnet (mounted near the sensor) is moved away from or closer to the sensor.The sensors are powered by a 3.6-volt lithium battery. The Long Life Door/Window Sensor battery cannot be replaced by installers or users. If you receive a low battery report, you must return the sensor to ITI for replacement.Tools Neededq#6 flathead screws or 18-gauge bradsqScrewdriver or brad driver qSmall wire cuttersqSensor and magnet spacers (optional)Installation GuidelinesqKeep all sensors within 100 feet of the panel. qMount the sensor on the door frame and the magnet on the door. If the sensor is to be used on double doors, mount the sensor on the least used door and the magnet on the other door.qMount sensors with screws or brads, not double-sided tape.qPlace sensors at least 5 inches above the floor to avoid damaging them.qUse spacers (not included) to keep sensors and magnets away from metal or metallic surfaces such as foil wall-paper.Door/Window Sensor SpacersWhite: ITI Part #60-189Brown: ITI Part #60-191Magnet SpacersWhite: ITI Part #60-188Brown: ITI Part #60-190qRemove the internal reed switch not being used.qAvoid mounting sensors in areas with a large quantity of metal or electrical wiring, such as a furnace or utility room.qAvoid mounting sensors in areas where they will be exposed to moisture.qAvoid mounting sensors in locations where the operat-ing temperature (10° to 120° F) will be exceeded.Do not remove the jumper from the Long-Life Door/Window Sensor circuit board! The sensor cannot work without the jumper.InstallationYou must be free of all static electricity when handling electronic components. Touch a grounded, bare metal surface before touching a circuit board or wear a grounded wrist strap.1. Decide if the sensor should be mounted horizontally or vertically by locating the alignment marks on the sen-sor and magnet plastic (see Figure 1.)The marks indicate reed switch locations. Each sensor uses only one of the two switches. You will remove the unused one in step 4.Figure 1. Alignment marks2. Remove the sensor cover by squeezing the cover ends firmly to release the tab on the cover from the slot on the sensor base.3. Remove the circuit board from the sensor base by pull-ing back the plastic tab and lifting the battery to release the circuit board. SENSOR END VIEW SENSOR SIDE VIEWMAGNETALIGNMENT MARKSALIGNMENT MARK8867G03A.DS4'RRU:LQGRZ/RQJ/LIH'RRU:LQGRZ6HQVRUV
2Door/Window & Long Life Door/Window SensorsConnecting External Switches4. Remove the unused reed switch, clipping the leads as close to the board as possible (see Figure 2.)Figure 2. Door/Window Sensor Circuit Boards5. Mount the sensor base with screws or brads. Use spac-ers to compensate for metal surfaces or height varia-tions.6. Remove the magnet from its base. Mount the magnet base no more than 3/8 inches away from the sensor base (see Figure 3). Replace magnet cover.)Figure 3. Mounted Sensor and MagnetMount the magnet so it won’t interfere with door or window openings. Do not use two-sided tape.7. Reattach the circuit board to the sensor base.8. Reattach the sensor cover to the sensor base.Connecting External SwitchesDoor/window sensors can be connected to either normally open (close on alarm) or normally closed (open on alarm) external switches. Wire multiple, normally closed switches in series. Wire multiple, normally open switches in parallel.Do not attempt to use the built-in reed switches and an external switch on the same door/window sensor. For high security installations, always remove both reed switches when connecting an external switch to the sensor terminals.In UL listed installations, only the normally closed con-figuration can be used.Materials NeededqHermetically sealed external switches (sealed reed switch) that supply a minimum 250-millisecond open or closure on alarm.qStranded 22-gauge wire.qInstallation GuidelinesqDo not use solid core wire.qDo not use mechanical switches.TA M PER  SW ITC HTERM INALSCIRCUITBOARDH O LD IN G  TA BREED SW ITCHES8867G 05A .D S F3.6 V O LT1/2 A A  B A TTE R YM O D E L 60-362JUM PERTA M PER  SW ITC HTERM INALSCIRCUITBOARDH O LD IN G  TA BREED SW ITCHES3.6 VOLT AA BATTERY8867G 04C .D S FM O D E L 60-641DOOR DOOR FRAMEMAGNET SENSOR8867G02A.DS4ALIGNMENT MARKS
3Door/Window & Long Life Door/Window SensorsProgrammingqIf you are connecting a remote device to a door/win-dow sensor, do not use the built-in reed switches.qDo not connect fast pulse devices (such as Window Bugs) to door/window sensors.qDo not use more than 25 feet of 22-gauge, stranded wire in any wire run.qDo not use more than 6 feet of untwisted wire in any wire run.qDo not connect more than five switches or more than one alarm screen to a door/window sensor.qDo not run wires parallel to electrical wires. If you can’t avoid a parallel wire run, keep it at least 18 inches away from electrical wiring.qIf necessary, you may cross electrical wires at a 90 degree angle.ProgrammingThe following steps describe the general guidelines for pro-gramming (learning) the sensor into panel memory. Refer to the specific panel installation instructions or reference man-ual for complete programming details.1. Set the panel to the program mode.2. Proceed to the LEARN SENSORS menu.3. Select the appropriate sensor group and sensor number assignments.4. Set the external switch (if one is connected) in the alarm condition (open for normally closed circuits; closed for normally open circuits).5. Trip the sensor’s tamper switch by removing the sensor cover.6. Exit program mode.7. Place the cover back on the sensor.TestingThe following steps describe the general guidelines for test-ing the sensor. Refer to the specific panel installation instructions or reference manual for complete testing details.1. Set the panel to the dealer sensor test mode.2. Trip the sensor.3. Listen for interior siren beeps to indicate how many rounds the panel receives from the sensor. You should hear 6 to 8 beeps.Notes on Testing the LongLife Door/Window SensorThe Long Life Door/Window Sensor has a built-in power-saver feature that turns on automatically when the sensor is tripped more than once, within a 4-1/4 minute time period.When the power-saver feature is on, the sensor transmits only half the usual number of data rounds when tripped. For example, during a dealer sensor test you normally expect to hear up to 8 data rounds. When the power-saver feature is on, you may hear only up to 4 data rounds.To be sure the sensor has acceptable transmitting range to the panel, leave the sensor undisturbed in the closed (non-alarm) condition for 5 minutes before tripping it for testing. This gives the sensor enough time to turn off the power-saver feature so you can get accurate sensor test results.SpecificationsOperating Temperature Range: 0° to 120° F.Compatibility: All Learn Mode panelsPower Source: 1/2 AA 3.6-volt lithium battery for 60-362, AA 3.6-volt lithium battery for 60-641Transmit Range: At least 500 feet, open airNoticesFCC Part 15 Information to the UserChanges or modifications not expressly approved by Interactive Technolo-gies, Inc. can void the user’s authority to operate the equipment.FCC Part 15 Class AThis equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense.FCC Part 15 Class BThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a resi-dential installation.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits.Consult the dealer or an experienced radio/TV technician for help.
4Door/Window & Long Life Door/Window SensorsNotices

Navigation menu