*Ài>ÀÞÊ£äÉÓÎÉ ITI Part Nos. 60-362 & 60-641 'RRU:LQGRZ /RQJ /LIH'RRU:LQGRZ 6HQVRUV 8867g01a.ds4 Document Number: 466-1022 Rev. D PRELIMINARY October 2000 Product Summary The Door/Window Sensor (60-362) and Long Life Door/ Window Sensor (60-641) can be installed on doors, windows, or virtually anything that opens and closes. During normal operation, the sensors transmit open (TRIP) and close (RESTORE) signals to the panel. The sensors also send a supervisory signal to the panel every 64 minutes. ÃÌ>>ÌÊÃÌÀÕVÌà q Remove the internal reed switch not being used. q Avoid mounting sensors in areas with a large quantity of metal or electrical wiring, such as a furnace or utility room. q Avoid mounting sensors in areas where they will be exposed to moisture. q Avoid mounting sensors in locations where the operating temperature (10° to 120° F) will be exceeded. 1/" Sensors transmit open and close signals to the panel when a magnet (mounted near the sensor) is moved away from or closer to the sensor. Do not remove the jumper from the Long-Life Door/ Window Sensor circuit board! The sensor cannot work without the jumper. The sensors are powered by a 3.6-volt lithium battery. Ìi Installation The Long Life Door/Window Sensor battery cannot be replaced by installers or users. If you receive a low battery report, you must return the sensor to ITI for replacement. 1/" You must be free of all static electricity when handling electronic components. Touch a grounded, bare metal surface before touching a circuit board or wear a grounded wrist strap. Tools Needed #6 flathead screws or 18-gauge brads Screwdriver or brad driver Small wire cutters Sensor and magnet spacers (optional) 1. The marks indicate reed switch locations. Each sensor uses only one of the two switches. You will remove the unused one in step 4. Installation Guidelines q Keep all sensors within 100 feet of the panel. q Mount the sensor on the door frame and the magnet on the door. If the sensor is to be used on double doors, mount the sensor on the least used door and the magnet on the other door. q Mount sensors with screws or brads, not double-sided tape. q Place sensors at least 5 inches above the floor to avoid damaging them. q Use spacers (not included) to keep sensors and magnets away from metal or metallic surfaces such as foil wallpaper. Door/Window Sensor Spacers White: ITI Part #60-189 Brown: ITI Part #60-191 Magnet Spacers White: ITI Part #60-188 Brown: ITI Part #60-190 Door/Window & Long Life Door/Window Sensors Decide if the sensor should be mounted horizontally or vertically by locating the alignment marks on the sensor and magnet plastic (see Figure 1.) ALIGNMENT MARKS SENSOR END VIEW SENSOR SIDE VIEW ALIGNMENT MARK MAGNET 8867G03A.DS4 Figure 1. Alignment marks 2. Remove the sensor cover by squeezing the cover ends firmly to release the tab on the cover from the slot on the sensor base. 3. Remove the circuit board from the sensor base by pulling back the plastic tab and lifting the battery to release the circuit board. *Ài>ÀÞÊ£äÉÓÎÉ Connecting External Switches 4. Remove the unused reed switch, clipping the leads as close to the board as possible (see Figure 2.) T A M P E R 6. S W IT C H Remove the magnet from its base. Mount the magnet base no more than 3/8 inches away from the sensor base (see Figure 3). Replace magnet cover.) M O D E L 6 0 -3 6 2 T E R M IN A L S 3 .6 V O L T 1 /2 A A B A T T E R Y ALIGNMENT MARKS C IR C U IT B O A R D H O L D IN G T A B R E E D S W IT C H E S 8 8 6 7 G 0 5 A .D S F SENSOR MAGNET T A M P E R S W IT C H M O D E L 6 0 -6 4 1 DOOR DOOR FRAME T E R M IN A L S 8867G02A.DS4 Figure 3. Mounted Sensor and Magnet 3 .6 V O L T A A B A T T E R Y Ìi Mount the magnet so it won’t interfere with door or window openings. Do not use two-sided tape. C IR C U IT B O A R D H O L D IN G T A B J U M P E R R E E D S W IT C H E S 8 8 6 7 G 0 4 C .D S F 7. Reattach the circuit board to the sensor base. 8. Reattach the sensor cover to the sensor base. Figure 2. Door/Window Sensor Circuit Boards 5. Mount the sensor base with screws or brads. Use spacers to compensate for metal surfaces or height variations. Connecting External Switches Door/window sensors can be connected to either normally open (close on alarm) or normally closed (open on alarm) external switches. Wire multiple, normally closed switches in series. Wire multiple, normally open switches in parallel. Do not attempt to use the built-in reed switches and an external switch on the same door/window sensor. For high security installations, always remove both reed switches when connecting an external switch to the sensor terminals. Ìi In UL listed installations, only the normally closed configuration can be used. Materials Needed q Hermetically sealed external switches (sealed reed switch) that supply a minimum 250-millisecond open or closure on alarm. q Stranded 22-gauge wire. q Installation Guidelines q Do not use solid core wire. q Do not use mechanical switches. Door/Window & Long Life Door/Window Sensors *Ài>ÀÞÊ£äÉÓÎÉ q If you are connecting a remote device to a door/window sensor, do not use the built-in reed switches. q Do not connect fast pulse devices (such as Window Bugs) to door/window sensors. q Do not use more than 25 feet of 22-gauge, stranded wire in any wire run. q Do not use more than 6 feet of untwisted wire in any wire run. q Do not connect more than five switches or more than one alarm screen to a door/window sensor. q Do not run wires parallel to electrical wires. If you can’t avoid a parallel wire run, keep it at least 18 inches away from electrical wiring. q If necessary, you may cross electrical wires at a 90 degree angle. Programming When the power-saver feature is on, the sensor transmits only half the usual number of data rounds when tripped. For example, during a dealer sensor test you normally expect to hear up to 8 data rounds. When the power-saver feature is on, you may hear only up to 4 data rounds. To be sure the sensor has acceptable transmitting range to the panel, leave the sensor undisturbed in the closed (nonalarm) condition for 5 minutes before tripping it for testing. This gives the sensor enough time to turn off the powersaver feature so you can get accurate sensor test results. Specifications Operating Temperature Range: 0° to 120° F. Compatibility: All Learn Mode panels Programming The following steps describe the general guidelines for programming (learning) the sensor into panel memory. Refer to the specific panel installation instructions or reference manual for complete programming details. Power Source: 1/2 AA 3.6-volt lithium battery for 60-362, AA 3.6-volt lithium battery for 60-641 Transmit Range: At least 500 feet, open air Notices 1. Set the panel to the program mode. 2. Proceed to the LEARN SENSORS menu. FCC Part 15 Information to the User 3. Select the appropriate sensor group and sensor number assignments. Changes or modifications not expressly approved by Interactive Technologies, Inc. can void the user’s authority to operate the equipment. 4. Set the external switch (if one is connected) in the alarm condition (open for normally closed circuits; closed for normally open circuits). FCC Part 15 Class A 5. Trip the sensor’s tamper switch by removing the sensor cover. 6. Exit program mode. 7. Place the cover back on the sensor. Testing This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense. FCC Part 15 Class B The following steps describe the general guidelines for testing the sensor. Refer to the specific panel installation instructions or reference manual for complete testing details. 1. Set the panel to the dealer sensor test mode. 2. Trip the sensor. 3. Listen for interior siren beeps to indicate how many rounds the panel receives from the sensor. You should hear 6 to 8 beeps. Notes on Testing the LongLife Door/ Window Sensor The Long Life Door/Window Sensor has a built-in powersaver feature that turns on automatically when the sensor is tripped more than once, within a 4-1/4 minute time period. Door/Window & Long Life Door/Window Sensors This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits. Consult the dealer or an experienced radio/TV technician for help. Notices *Ài>ÀÞÊ£äÉÓÎÉ Door/Window & Long Life Door/Window Sensors
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Page Mode : UseOutlines Create Date : 1910:01:02 31:21:11 Producer : Acrobat Distiller 3.01 for Windows Title : Untitled Document Creator : FrameMaker 5.5.3L15aEXIF Metadata provided by EXIF.tools