UTC Fire and Security Americas 798A-THERM Wireless Thermostat User Manual

UTC Fire & Security Americas Corporation, Inc. Wireless Thermostat

User Manual

1'LDORJ5)(OHFWURQLF7KHUPRVWDWITI Part No. 60-XXX 43-EURInstallation InstructionsDocument Number: 466-1931 Rev. A PRELIMINARYDecember 2001Preliminary 12/19/01Product SummaryThe Dialog RF Electronic Thermostat provides a money-saving and convenient way to monitor and control tempera-tures. The Thermostat uses low and high temperature limits to save energy by overriding the existing HVAC thermostat. When the Thermosatat is on, temperature limits determine when the heat or air conditioning turns on. when the Ther-mostat is off, the HVAC thermostat controls heat and air conditioning.For example, if the HVAC thermostat is set for 68° F and the RF Thermostat has a high limit of 80° F, the RF Ther-mostat prevents the air conditioner from turning on until the temperature reaches 80° F.A temperature sensor within the RF Thermostat monitors the temperature and reports a freeze alarm to the panel if the temperature drops below the set freeze temperature (default = 42° F).NoteDepending on where the RF Thermostat is located, additional freeze sensors may need to be placed throughout the residence to provide adequate freeze protectionThe Dialog RF Electronic Thermostat is compatible with Simon 3 panels.Installation Guidelines❑Use 22-gauge or larger stranded wire from the RF Thermostat to the HVAC thermostat.❑Install the RF Thermostat on an inside wall next to, or as close as possible, to the existing HVAC thermostat. This keeps the temperature difference between the two thermostats to a minimum.❑Programmable thermostats that use a battery to keep time and other programmed settings may lose time and/or programmed settings when the RF Thermostat is turned on. This happens when the RF Thermostat relay is interrupted by the HVAC thermostats main power, forcing it to rely on battery power to save time and pro-grammed settings. As a result, the HVAC thermostat battery may need to be replaced more often, depending on how often and how long the RF Thermostat is turned on.❑Test the RF Thermostat from a desired location before mounting it to the wall. This will verify that RF com-munication can be established with the panel.❑Whenever possible, keep all sensors within 100 feet of the panel.❑Avoid installing your RF Thermostat on plaster walls with wire mesh (metal lath) embedded in them. This can interfere with the wireless range/communication between the RF Thermostat and the panel.Tools and Supplies❑Screwdrivers (Phillips and Flathead)❑Screws and anchors (included)❑Digital voltmeter❑Drill with bits❑Wire cutters/snippers❑22-gauge or larger stranded wire❑Pen or pencilInstallationInstallation consists of mounting the RF Electronic Ther-mostat to the wall (as close as possible to the existing ther-mostat) and wiring it to the existing HVAC thermostat.Mounting the RF Thermostat to the wall:1. Press down on the top two latches of the RF Thermo-stat and pull the front away from the base (see figure x). Set the front part aside.You must be free of all static electricity when handling electronic components. Touch a grounded bare metal surface or wear a grounding strap before touching the circuit board.2. Place the RF Thermostat on the wall (with the word “TOP” upright and facing you) at the desired mounting location and mark the two upper mounting holes and the base opening (see figure x).
Preliminary 12/19/0123. Drill a hole using a 3/16” bit at each mounting hole location. Make a hole at the base opening location to run the wires from the HVAC thermostat to the RF Thermostat.4. Install the two wall anchors supplied.5. Mount the base to the wall using the two #6 x 1/2” self-tapping screws supplied.6. Create a hole in the wall in the Wire Opening to run the wiring from the existing HVAC thermostat to the RF Thermostat.Wiring the RF Thermostat to the HVAC thermostat:Some thermostats control heating and cooling, others con-trol only heating. A heating/cooling thermostat uses four wires and a heating-only thermostat usually has two.NoteIf the thermostat wire colors are different than those described above, contact a qualified HVAC service person for wiring information about your specific ther-mostat. Be sure to give the service person the manu-facturer name and model number of the thermostat.To connect a four-wire thermostat:1. Remove the red wire (power feed) from the thermostat and connect it to the RF Thermostat terminal 1.2. Connect a 22-gauge or larger wire from the RF Ther-mostat terminal 2, to the thermostat terminal where the red wire (power feed) was previously connected.To connect a two-wire thermostat:1. Remove one of the wires from the thermostat and con-nect it ot the RF Thermostat terminal 1.2. Connect a wire from the RF Thermostat terminal 2, to the thermostat terminal where the original wire had been connected.ProgrammingFor information on operating, programming, testing, and deleting an RF Thermostat from panel memory, please refer to your Simon 3 Installation Instructions or User’s Manual.NoteThe RF Thermostat must be installed and powered up for a minimum of 15 minutes before adjusting its tem-perature to ensure consistent readings between it and the house thermostat. For best results, wait an hour before adjusting the RF Thermostat temperature.TestingSpecificationsCompatibility: ............ Simon 3Power Requirements: ? Storage Temperature: -30° to 140°F (-34° to 60°C)Operating Temperature: 32° to 140°F (0° to 60° C)Color: .......................... Belgian GrayCase Material:............. ABS PlasticDimensions: ................ 3.75” x 5.5” x 1.2” (L x W x D)Installation:  ................ Wall mountingUL Listings: ................FCC NoticeThis device complies with FCC Rules Part 15. Operation is subject to the following two conditions:1. This device may not cause harmful interference.2. This device must accept any interference that may be received, including interference that may cause undesired operation.Changes or modifications not expressly approved by Interlogix, Inc. can void the user’s authority to operate the equipment.FCC ID: B4Z-798A-THERMNoticesFour-Wire Thermostat Color CodeWire FunctionRed Power feed to thermostatGreen Fan controlYellow CoolingWhite Heating

Navigation menu