UTC Fire and Security Americas 839-TWTP Two Way RF Touch Pad User Manual

UTC Fire & Security Americas Corporation, Inc. Two Way RF Touch Pad

Users Manual

1,QVWDOODWLRQ,QVWUXFWLRQV*(6HFXULW\'Product SummaryThe wall-mounted wireless Dialog QS1500 Touchtalk Interactive Keypad combines a conven-tional Learn Mode™ keypad with an RF receiver, speech chip, and voice amplification circuit for your Simon 3 ® security system. The QS1500 Touchtalk Interactive Keypad is an alkaline battery-powered, wireless keypad designed to provide users a convenient option for the following system operations:• Arm the system (doors, windows, and motion sensors).• Arm the system with No Entry Delay.• Disarm the system.• Activate a panic alarm to call the central monitoring station in a non-medical emergency.• Check system status.• Turn system controlled lights on or off (all or individual).• Enables the user to hear the voice feedback that is heard at the Simon 3 Control Panel.The keypad has two operating modes: key and chime.In key mode, voice feedback is heard only at the keypad when a system command is entered. Examples of this would be: system status, arming and disarming. In this mode the keypad does not repeat siren sounds and will not make any alarm sounds or status beeps. This feature extends battery life to the keypad and gives feedback only to the user who needs it. When the keypad is in key mode it is compatible with Simon 3 panels version 3.3 and newer.In chime mode, all voice feedback that is heard in key mode, plus, trouble beeps, entry/exit beeps and alarm sounds (Fire, Aux, Police) are heard at the keypad. The keypad will also respond to panel broadcast messages at multiple keypads. While in chime mode the keypad can be supervised and will send supervision messages to the panel. In chime mode the keypad is compatible with Simon 3 panels version 4.0 and newerVoice feedback depends on how Simon 3 panel options 41 and 87 are set. See the Simon 3 Instal-lation Instructions (466-1873) for more information.Voice feedback is heard at all keypads. If the keypad is talking, the panel is silent. When the panel is talking, the keypad is silent.The keypad has no tamper detection. A low battery condition is automatically detected by the keypad and communicated to the control panel.Installation Installation of the QS1500 Touchtalk Interactive Keypad includes guidelines for installing, pro-gramming, sensor testing, improving sensor communication and mounting the keypad.Installation GuidelinesUse the following guidelines when adding this keypad to your Simon 3 system:• Program the keypad as key or chime mode.• Keypads are learned into the control panel as sensors.Part No. 60-924-01-3The keypad has limited audio power. Therefore, the keypad should not be relied on for alarm announcements and is no substitute for an alarm siren.Warning!'RFXPHQW1XPEHU5HY$-XQH'LDORJ467RXFKWDON,QWHUDFWLYH.H\SDG
2Dialog QS1500 Touchtalk Interactive Keypad Installation Instructions • Key mode keypads should be programmed using sensor groups 01, 03, 06, or 07 for non supervised use.• Chime mode keypads can be programmed using sensor groups 01, 03, 06 or 07 for non supervised use or sensor groups 00, 02, 04 or 05 for supervised use.• The keypad must be deleted and reprogrammed into panel memory every time the key-pad operating mode is changed.• Each learned keypad uses one of the available sensor numbers (24 total sensors/zones can be used with the Simon 3 panel).• When the keypad is mounted on the wall, it might not work properly if mounted too close to the Simon 3 panel.ProgrammingFor complete programming instructions, refer to your Simon 3 installation instructions. The keypad must be programmed for key or chime mode before programming into panel mem-ory. ¾To program the keypad mode:1. Remove the mounting plate on the back of the keypad.2. Insert two of the three batteries into the keypad.Note To check the software ver-sion of the keypad, press 1 after Step 3.3. While holding down the Lights On and Lights Off keys, insert the third battery. Release the keys. The keypad will sound one long beep.4. Immediately press 8 to program the keypad for key mode. The keypad announces “No chime hello, touchpad OK”. OR Press 9 to program the keypad for chime mode. The keypad announces “Chime hello, touchpad OK”.Note  The “Chime” and “No chime” announcements from the keypad only describe the keypad mode being programmed. The announcements don’t describe doors and special motion chime functions programmed at the panel.After programming the mode, the keypad must be programmed into the panel.¾To program the keypad into panel memory:1. Open the control panel cover.2. Enter Utility Access Code 1 or 2 using the red numbered keys.3. Press Add. The panel announces “Select from Main Menu.”4. Press Sensor/Remote. The panel announces “Press button on sensor.” Note If the keypad doesn’t announce “OK”, press Can-cel at the panel and repeat process starting from Step 3.5. Press the Lights Off button on the keypad six times in rapid succession. On the sixth key press the keypad makes a long beep. The keypad announces “OK”, to indicate that it has been learned into the panel. Panel announces keychain remote.Note For a more specific location name, press Option # for compass directions (north, northeast, east, southeast, south, southwest, west, northwest).6. Press Sensor/Remote repeatedly until you hear the sensor name or item you want to use. Each name may be used more than once.7. Press DONE when you hear the desired sensor name. The panel announces “Use num-bered keys to enter sensor group.”Note If you wish to use a sensor number other than the next one available, use the num-bered keys to enter a 2 digit sensor number immediately after entering the sensor group.8. Enter the 2-digit sensor group (Key mode: 01, 03, 06 or 07 OR Chime mode: 00 through 07). The panel announces the sensor group and the first available sensor number, then prompts you to press DONE to accept.9. Press DONE. The panel confirms programming by announcing the sensor number, name, and group.Performing a Sensor TestThe keypad is sensitive to its orientation to the control panel. For that reason, it is recom-mended that you test the keypad prior to mounting it on the wall. The following steps describe the guidelines for testing sensors used in a Simon 3 system.1. Make sure the panel is disarmed.2. Open the panel cover. 3. Enter the appropriate access code.
3Dialog QS1500 Touchtalk Interactive Keypad Installation Instructions 4. Press Test.The panel responds with Sensor test, press again to change or DONE to select.5. Press DONE.Note To verify the communication between the panel and the keypad, close the panel’s cover to put the panel in run mode. Press the SYSTEM STATUS button on the key-pad. The keypad should announce the correct sys-tem status (i.e. “System Dis-armed”).The panel will prompt you to trip each sensor one at a time. To trip the keypad, press and hold the two Emergency buttons simultaneously for three seconds. You may follow the panel voice prompting or test the sensors in any order. Use the “Sensor Tripping Instructions” table in your Simon 3 Installation Manual to trip sensors.We recommend that you test the keypad after all programming is completed and whenever a key-pad-related problem occurs.If a Keypad Fails a Sensor TestIf panel sirens do not beep when a keypad is tripped, use a GE Security RF Sniffer (60-401) test tool to verify that the keypad is transmitting. Constant beeps from the RF Sniffer indicate a run-away (faulty) keypad. Two or three beeps from the RF Sniffer indicates the keypad is functional, but may have to be relocated. If the keypad is faulty, replace it.How to Improve Sensor Communication• Relocate the keypad.• If necessary, replace the keypad.¾To Relocate a Keypad:1. Test the keypad a few inches from the original position.2. Increase the distance from the original position. Retest until an acceptable location is found.3. Mount the keypad in the new location (see Mounting the Keypad section).4. If no location is acceptable, replace the keypad.¾To Replace a Keypad:1. Test a known good keypad at the same location.2. If transmission beeps remain below the minimum level, avoid mounting a keypad at the loca-tion.3. If the replacement keypad functions, contact GE Security for repair or replacement of the problem keypad.Mounting the KeypadTo mount the keypad on a wall, do the following:1. Open the door of the keypad.2. Gently pull down on the tab at the bottom of the keypad to separate the keypad body from the keypad mounting plate (Figure 1).3. Hold the keypad mounting plate against the wall. Using the two screws included with the key-pad, attach the keypad mounting plate to the wall through the mounting holes (Figure 2).Figure 1. Keypad Bottom View Figure 2. Keypad Mounting PlateMounting HolesTab
4Dialog QS1500 Touchtalk Interactive Keypad Installation Instructions 4. Reattach the keypad to the mounting plate.Testing the Keypad After MountingNote While the sensor test is a valuable installation and ser-vice tool, it only tests sensor operation for the current conditions. You should per-form a sensor test after any change in environment, equipment, or programming.Repeat the steps listed in the “Performing a Sensor Test” section in this manual.Keypad Operation• Numeric Buttons (0 - 9) - Used to enter an access code or turn individual lights on and off.• Disarm Button - The control panel is disarmed to level 0 or 1. (Level 0 all sensors except smoke alarms are disarmed. Level 1 doors, windows, and motion sensors are disarmed). Dis-arm also requires the access code to be entered.• ARM Doors & Windows Button - The control panel is armed to level 2.• ARM Motion Sensors Button - The control panel is armed to level 3. If the ARM Doors & Windows button was previously pressed, the control panel is armed to level 4 (Doors/Win-dows and Motion Sensors armed).• Lights On Button - Pressing this button twice quickly turns on all lights controlled by the sys-tem. Pressing this button once plus 1-8 will turn on that individual numbered light.• Lights Off Button - Pressing this button twice quickly turns off all lights controlled by the sys-tem. Pressing this button once plus 1-8 will turn off that individual numbered light.• Emergency Buttons - The panel will react according to the sensor group they are learned in to (00-07) Intrusion, Silent or Emergency. Press and hold both keys OR press both keys twice quickly, to activate alarm reports to the central station.Battery ReplacementWhen the batteries get low on the keypad, the keypad announces “Touchpad low battery”. The panel announces “<Sensor name> low battery”.Note Avoid pressing the buttons on the keypad during battery replacement.Remove the touchpad from the mounting plate and replace all three batteries with AAA alkaline batteries.After replacing the batteries, run a sensor test to realign the keypad to the panel.Specifications Compatibility: ..........................Simon 3 (version 3.3 and later)Power Requirements: ..............3 AAA Alkaline batteriesStorage Temperature: ..............-40° to 140° F (-34° to 60° C) Operating Temperature: .........32° to 120° F (0° to 49° C)Maximum Humidity:...............90% relative humidity, non-condensingDimensions: ..............................3.6 x 1.2 x 5.4 in. (W x D x H)Installation: ..............................Wall mountingListings:FCC Notice1. This device may not cause harmful interference.2. This device must accept any interference that may be received, including interference that may cause undesired operation.Notices)*(6HFXULW\

Navigation menu