UTC Fire and Security Americas 910C-SIMON GE Simon XT User Manual simonxt iman

UTC Fire & Security Americas Corporation, Inc. GE Simon XT simonxt iman

Manual

Download: UTC Fire and Security Americas 910C-SIMON GE Simon XT User Manual simonxt iman
Mirror Download [FCC.gov]UTC Fire and Security Americas 910C-SIMON GE Simon XT User Manual simonxt iman
Document ID921065
Application IDXraIkVE2cu7GA0EyteG4Lw==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize207.39kB (2592356 bits)
Date Submitted2008-03-28 00:00:00
Date Available2008-03-28 00:00:00
Creation Date2007-11-29 14:58:21
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2008-03-19 09:52:28
Document Titlesimonxt-iman.book
Document CreatorFrameMaker 7.1
Document Author: 208049320

600-1054-95R
Simon XT
Installation Manual
Pb
Copyright
Copyright © 2007 GE Security. All rights reserved.
This document may not be copied in whole or in part or otherwise reproduced without prior written consent
from GE Security except where specifically permitted under US and international copyright law.
Document number: 466-2265D (November 2007).
Disclaimer
The information in this document is subject to change without notice. GE Security, Inc. (“GE Security”)
assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or
risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any
of the contents of this document. For the latest documentation, contact your local supplier or visit us online
at www.gesecurity.com.
This publication may contain examples of screen captures and reports used in daily operations. Examples
may include fictitious names of individuals and companies. Any similarity to names and addresses of actual
businesses or persons is entirely coincidental.
Trademarks and patents
GE and the GE monogram are registered trademarks of General Electric Company.
Simon and Simon XT are trademarks of GE Security.
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers
or vendors of the respective products.
This product and the use of this product may be covered by one or more of the following patents:
5,805,063; 5,872,512; 5,942,981; 5,686,896; 5,686,885; or 4,855,713.
Software license agreement
Important: This end-user license agreement (“Agreement”) is a legal agreement between GE SECURITY and
You. Read the following terms and conditions carefully before installing or using this Software. This agreement provides a license from GE SECURITY to use the Software. It also contains warranty information, disclaimers, and liability limitations. Installing and/or using the Software confirms Your agreement to be bound
by these terms and conditions. If You do not agree with these terms and conditions, do not install or use the
Software or, if already installed, immediately cease all use of the Software and promptly uninstall all components of the Software.
1. Definitions. The following definitions apply to this document:
a. “GE SECURITY”, with respect to title to or warranty of the Software, means GE Security Inc., a Delaware corporation.
b. “Software” mean the executable software or firmware programs and accompanying documentation installed on the GE SECURITY products, plus any upgrades, modified versions, updates, additions, and copies of the software furnished to Customer during the term of the license granted
herein.
c. “Documentation” means all associated media, printed materials, and electronic documentation
accompanying the Software.
d. “Licensed Product” means the Software and Documentation.
e. “Customer” means the person or organization, or parent or subsidiary thereof, who uses the Software for its intended purposes, and excludes distributors, authorized resellers, value-added resellers
and original equipment manufacturers. Customer may be referred to as You or Your, whether an
individual or a business entity of any kind.
f. “Machine” means the computer, workstation, terminal, or other hardware product on which the
Software is installed.
2. License. All rights to and in the Licensed Product, including, but not limited to, copyrights, patents,
trademarks, and trade secrets, belong to GE SECURITY, and GE SECURITY retains title to each copy of the
Software. You agree that GE SECURITY at any time, upon reasonable notice, may audit Your use of the
Software for compliance with the terms and conditions of this Agreement. Subject to the terms and conditions of this Agreement, GE SECURITY grants You a nonexclusive license to use the Software, but only in
the country where acquired, provided that You agree to the following:
You may:
a. install and use the Software on a single Machine at one time, unless You have purchased additional
copies of the Software, in which case You may install the software on the number of Machines for which
You have purchased copies of the Software;
b. use the original copy of the Software provided to You for backup purposes.
You may not:
a. transfer or distribute the Licensed Product to others, in electronic format or otherwise, and this Agreement shall automatically terminate in the event of such a transfer or distribution;
b. use the Software over a computer network;
c. sell, rent, lease, or sublicense the Software;
d. copy or modify the Licensed Product for any purpose, including for backup purposes.
iii
3. Term. This Agreement is effective until terminated. You may terminate this Agreement by uninstalling
all components of the Software from all Machines and returning the Software to GE SECURITY.
GE SECURITY may terminate this Agreement if You breach any of these terms and conditions. Upon termination of this Agreement for any reason, You agree to uninstall all components of the Software and
return the Licensed Product to GE SECURITY. All provisions of this Agreement relating to (i) disclaimer of
warranties; (ii) limitations on liability, remedies, and damages; and (iii) GE SECURITY’s proprietary rights,
shall survive termination of this Agreement.
4. Object code. The Software is delivered in object code only. You may not alter, merge, modify, adapt,
or translate the Software, nor decompile, disassemble, reverse-engineer, or otherwise reduce the Software to a human-perceivable form, nor create derivative works or programs based on the Software.
5. Limited warranty. GE SECURITY warrants that for one (1) year from the date of delivery of the
Licensed Product (Software Warranty Period), the functions contained in the Software will be fit for their
intended purpose as described in the applicable Documentation from GE SECURITY, and will conform in all
material respects to the specifications stated in such Documentation. GE SECURITY does not warrant
that the operation of the Software will be uninterrupted or error-free. GE SECURITY does warrant that the
media on which the Software is furnished will be free from defects in materials and workmanship under
normal use for a period of thirty (30) days from the date of delivery (Media Warranty Period). Except as
specifically provided therein, any other software and any hardware furnished with or accompanying the
Software is not warranted by GE SECURITY.
Your exclusive remedy under this limited warranty for nonconforming Software shall be repair or replacement of the Software, at the sole discretion of GE SECURITY. To obtain a repair or replacement of nonconforming Software, contact GE SECURITY Customer Service toll-free at 888-GESECURity or online at
www.gesecurity.com during the Software Warranty Period.
Except as expressly provided above, the licensed product is provided “as is” without warranty of any kind,
either expressed or implied, including, but not limited to, implied warranties of merchantability or fitness
for a particular purpose and, except as expressly provided above, You assume the entire risk as to the
quality and performance of the licensed product.
6. Limitation of liability. GE SECURITY’s sole obligation or liability under this agreement is the repair
or replacement of nonconforming software and/or defective media according to the limited warranty
above. In no event will GE SECURITY be liable for damages, whether consequential, incidental, or indirect,
nor for loss of data, loss of profits, or lost savings, arising from use or inability to use the software or documentation (or any hardware furnished with the software), even if GE SECURITY has been advised of the
possibility of such damages, nor for any claim by any third party.
7. General. Any materials provided to You by GE SECURITY shall not be exported or reexported in violation of any export provisions of the USA or any other applicable jurisdiction. Any attempt to sublicense,
assign, or transfer any of the rights, duties, or obligations hereunder shall be void. This Agreement shall
be governed by and interpreted under the laws of the State of New York, United States of America,
without regard to conflicts of law provisions. You hereby consent to the exclusive jurisdiction of the state
and federal courts located in Multnomah County, Oregon, to resolve any disputes arising under or in connection with this Agreement, with venue in Portland, Oregon.
8. Restricted rights legend. The Licensed Product is provided with RESTRICTED RIGHTS. In the event
the United States Government or an agency thereof is granted a license, the following additional terms
apply: Restricted Computer Software, as defined in the Commercial Computer Software–Restricted Rights
clause at Federal Acquisition Regulations 52.227-19, and the restrictions as provided in subparagraphs
(c)(1) and (c)(2) thereof; and as applicable, the Government’s rights to use, modify, reproduce, release, perform, display, or disclose the Software also are restricted as provided by paragraphs (b)(2) and (b)(3) of the
Rights in Noncommercial Technical Data and Computer Software–Small Business Innovative Research
(SBIR) Program clause at DFARS 252.227-7018.
9. Acknowledgment. You acknowledge that You have read and understand this agreement and agree
to be bound by its terms. You further agree that this agreement is the complete and exclusive statement
of the agreement between You and GE SECURITY, and supersedes any proposal or prior agreement, oral
or written, and any other communication relating to the subject matter of this agreement.
Intended use
Use this product only for the purpose it was designed for; refer to the data sheet and user documentation.
For the latest product information, contact your local supplier or visit us online at www.gesecurity.com.
iv
Simon XT
Installation Manual
FCC compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
If this equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.
FCC Part 15 registration number: B4Z-910C-SIMON.
Part 68. This equipment complies with Part 68 of the FCC rules and the requirements adopted by ACTA. A
label on this equipment contains a product identifier in the format US:AAAEQ##TXXXX. You must provide this
number to the telephone company upon request.
FCC Part 68 registration number: US:B4ZAL02B55910.
The plug and jack used to connect this equipment to the premises wiring and telephone network comply with
the applicable FCC Part 68 rules and requirements adopted by ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is
also compliant. See the installation instructions for details.
The REN is used to determine the maximum number of devices that may be connected to your telephone
line. Excessive RENs on a telephone line may result in devices not ringing in response to an incoming call.
In most cases, the sum of all device RENs should not exceed five (5.0). To be certain of the number of devices
that may be connected to a line, as determined by the total RENs, contact your local telephone company.
For products approved after July 23, 2001, the REN is part of the identifier with the format
US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point. (For example, 03 is a
REN of 0.3). For earlier products, the REN is separately shown on the label.
Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation.
It must be able to do this even if other equipment (telephone, answering system, computer modem, etc.)
already has the telephone line in use. To do so, alarm dialing equipment must be connected to a properly
installed RJ31X jack that is electrically in series and ahead of all other equipment attached to the same telephone line. If you have any questions concerning these instructions, consult your local telephone company or
a qualified installer about installing an RJ31X jack and alarm dialing equipment for you.
If this equipment causes harm to the telephone network, the telephone company may temporarily disconnect your service. The telephone company may notify you in advance, but when advance notice isn’t practical, they will notify you as soon as possible and advise you of your right to file a complaint with the FCC.
The telephone company may make changes in their facilities, equipment, operations, or procedures that
could affect the operation of the equipment. If they do, they will notify you in advance so you can make the
modifications to maintain uninterrupted service.
This equipment may not be used on coin service provided by the telephone company. Connection to party
line service is subject to state tariffs. Contact the state public utility commission, public service commission,
or corporation commission for information.
If you experience trouble with this equipment, please contact the company that installed the equipment for
service and repair information. If the equipment is causing harm to the telephone network, the telephone
company may ask you to disconnect the equipment until the problem is resolved.
v
Contents
Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
Conventions used in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Safety terms and symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Materials needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Chapter 1.
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
System components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Standard panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Chapter 2.
Planning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Planning the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Control panel location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Planning sensor types and locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
System configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Emergency planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Chapter 3.
Installing the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
UL listed installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
SIA system requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Central station reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
UL Canada listed installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
California state fire marshall listed installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Opening panel cover and chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Mounting the panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Connecting hardwired devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
HW1 I/O, HW2 in, and HW1&2 DC out terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Interior sirens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
LD105 hardwired interior siren. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Hardwired contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Wiring a phone line to the panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Full line seizure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Wiring the power transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Powering up the panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Installing X10 modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
vi
Simon XT
Installation Manual
Chapter 4.
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Programming overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Entering and exiting the system menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Menu navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Set clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Contrast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
System programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Access codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Phone numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Phone options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Touchpad options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
System options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Siren options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Piezo beep options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Audio verification options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Light control (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
System tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Resetting memory to the factory defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Chapter 5.
Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Sensor testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
If a sensor fails the sensor test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Phone communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Offsite phone operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Central station communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Two-way voice operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Voice event notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
X10 operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Manual lamp module control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
X10 siren and lamp module functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Chapter 6.
Troubleshooting and support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Contacting us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Online resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Appendix A. Specifications and tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Sensor names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
vii
Tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Table 16.
Table 17.
Table 18.
Table 20.
Table 19.
Table 21.
Table 22.
Table 23.
Table 24.
Table 25.
Table 26.
Table 27.
Table 28.
Table 29.
Table 30.
Table 31.
Table 32.
Table 33.
Table 34.
Table 35.
Table 36.
Table 37.
Table 38.
Table 39.
Table 40.
Supported devices..................................................................................................................................................................... 3
Panel hardware capabilities.................................................................................................................................................. 4
Recommended sensor groups ............................................................................................................................................. 7
Sensor group characteristics................................................................................................................................................ 7
Sensor assignments/locations ............................................................................................................................................. 9
System programming menu options ...............................................................................................................................11
SIA setting requirements ......................................................................................................................................................19
Nonprogrammable (hard coded) system operation ..................................................................................................20
Simon XT panel keys and features....................................................................................................................................35
Simon XT menu structure....................................................................................................................................................36
Simon XT programming codes ..........................................................................................................................................39
Access codes .............................................................................................................................................................................40
Security........................................................................................................................................................................................41
Phone numbers ........................................................................................................................................................................43
Phone options ...........................................................................................................................................................................43
Device programming .............................................................................................................................................................45
Sensors ........................................................................................................................................................................................46
Reporting options ....................................................................................................................................................................47
Timers...........................................................................................................................................................................................49
Communication modes.........................................................................................................................................................49
Touchpad options....................................................................................................................................................................51
System options .........................................................................................................................................................................51
Siren options..............................................................................................................................................................................52
Panel piezo beeps....................................................................................................................................................................53
Audio verification.....................................................................................................................................................................54
Light control...............................................................................................................................................................................57
System tests ..............................................................................................................................................................................57
Control panel test sequence ...............................................................................................................................................60
Arming levels.............................................................................................................................................................................60
Sensor tripping instructions ................................................................................................................................................61
Minimum beeps........................................................................................................................................................................62
Phone commands ...................................................................................................................................................................63
Sensor/user report codes.....................................................................................................................................................64
Audio verification set..............................................................................................................................................................65
Alarm siren and X10 light information ...........................................................................................................................66
Technical support....................................................................................................................................................................70
Simon XT specifications .......................................................................................................................................................72
Alphabetical list of sensor name segments ..................................................................................................................72
Sensor name segments by index number (in scrolling order) ...............................................................................73
Simon XT system quick reference ....................................................................................................................................74
viii
Simon XT
Installation Manual
ix
Preface
This is the GE Simon XT Installation Manual for model 600-1054-95R. This document includes an overview
of the product and detailed instructions explaining:
•
•
how to install; and
how to set up the product for customer use.
There is also information describing how to contact technical support if you have questions or concerns.
To use this document effectively, you should have a basic knowledge of electrical wiring and low-voltage
electrical connections.
Read these instructions and all ancillary documentation entirely before installing or operating this product. The
most current versions of this and related documentation may be found on our website. Refer to Online
resources on page 70 for instructions on accessing our online publication library.
Note: A qualified service person, complying with all applicable codes, should perform all required hardware installation.
Conventions used in this document
The following conventions are used in this document:
Bold
Menu items and buttons.
Italic
Emphasis of an instruction or point; special terms.
File names, path names, windows, panes, tabs, fields, variables, and other GUI elements.
Titles of books and various documents.
Blue italic
(Electronic version.) Hyperlinks to cross-references, related topics, and URL addresses.
Monospace
Text that displays on the computer screen.
Programming or coding sequences.
Safety terms and symbols
These terms may appear in this manual:
CAUTION: Cautions identify conditions or practices that may result in damage to the equipment or other property.
WARNING: Warnings identify conditions or practices that could result in equipment damage or serious personal injury.
Materials needed
•
•
Pencil
Phillips screwdriver
x
Simon XT
Installation Manual
Chapter 1 Introduction
This chapter provides an overview of the system and an outline of the steps you
need to perform before you begin installing and configuring your security system.
In this chapter:
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
System components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Standard panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2
Simon XT
Installation Manual
Product overview
This security system can be used as a fire warning system, an intrusion alarm system, an emergency
notification system, or any combination of the three. The system (Figure 1) has three types of components:
•
•
•
Self-contained control panel
Devices that report to the panel
Devices that respond to commands from the panel
Note: The keyfob and X10 modules have not been investigated by UL.
Figure 1. Simon XT system
Keyfob
Door/window sensor
PIR motion sensor
Smoke detector
Remote
handheld
touchpad
X10 universal module
X10 lamp module
X10 appliance module
Note: The universal, lamp, and appliance modules require a special transformer.
The self-contained panel provides the main processing unit for all system functions. It receives and responds to
signals from wireless sensors and wireless touchpads throughout the premises. For monitored systems, the
panel can be connected to the premises phone line for central monitoring station reporting.
You can program the panel onsite from the keypad or remotely using Enterprise Downloader software. See
Programming on page 33 for complete onsite programming instructions.
Chapter 1
Introduction
System components
The system can monitor up to 40 sensors and may use any of the devices listed in Table 1.
Table 1.
Supported devices
Device
Description
Door/window sensor
(60-670)
For intrusion protection, install door/window sensors on all ground-floor doors and windows. At a
minimum, install them in the following locations:
• All easily accessible exterior doors and windows.
• Interior doors leading into the garage.
• Doors to areas containing valuables such as cabinets and closets.
Indoor motion sensor
(60-639)
Indoor motion sensors are ideal whenever it is not practical to install door/window sensors on every
opening. Identify areas where an intruder is likely to walk through. Large areas in an open floor plan,
downstairs family rooms, and hallways are typical locations for indoor motion sensors. For
installations with pets, use the SAW Pet Immune PIR (60-807).
Outdoor motion sensor
(60-639)
Use outdoor motion sensors to detect motion in a protected outdoor area. Detected motion in this
protected area can sound chimes or turn on outside lights.
X10 module a
When the panel is powered using the line carrier power transformer, the system can work with any
of the following modules:
• X10 lamp module (13-403)
• X10 appliance module (13-402)
• X10 power horn/remote siren module (13-398)
Freeze sensor (60-742)
Freeze sensors detect low temperature conditions which may indicate a furnace failure. The sensor
contains a bimetallic thermal switch connected to the built-in transmitter. The sensor transmits an
alarm signal to the panel when the surrounding temperature drops to about 41°F (5°C). When the
temperature rises to 50°F (10°C), the sensor transmits a restore signal.
Water sensor (60-744) a Water sensors detect a water leak/rising water. The detector is connected to the sensor by an 8foot (2.4-meter) cable. Water that reaches both detector contact points activates the sensor,
causing it to transmit an alarm signal.
Smoke sensor (60-84895)
Smoke sensors provide fire protection by causing an alarm to sound throughout the house. You can
add smoke sensors near sleeping areas and on every floor of the house. Avoid areas that could have
some smoke or exhaust such as attics, kitchens, above fireplaces, dusty locations, garages, and
areas with temperature extremes. In these areas you may want to install Rate-of-Rise sensors to
detect extreme temperature changes. Emergency planning on page 16 and the instructions
packaged with the smoke sensor for complete placement information.
Carbon monoxide (CO)
alarm (60-652-95) a
The Learn Mode™ CO alarm alerts users to hazardous levels of carbon monoxide gas. If dangerous
concentrations of gas are present, the red indicator light comes on, the internal siren goes off, and
an alarm is transmitted to the panel. The panel sounds its own alarm and reports to the central
station.
Keyfob (60-659) a
The keyfob (keychain touchpad) lets you turn the system on and off from right outside the home or
activate a panic alarm if there is an emergency. If you have X10 lamp modules, you can use keyfobs
to turn all system controlled lights on and off.
ELM (encrypted learn
The ELM (encrypted learn mode™) 2-button keyfob is an alkaline battery-powered, wireless
mode) keyfob (60-832) a touchpad that allows users to arm and disarm their system, and activate a police or auxiliary panic
alarm. Random encrypted signal transmissions provide high security to help prevent signal copying.
4
Simon XT
Installation Manual
Table 1.
Supported devices (continued)
Device
Description
Remote handheld
touchpad (60-671)
The remote handheld touchpad lets you turn the system on and off while in the home, turn system
controlled lights on and off (all or individual lights), or activate a panic alarm if there is a nonmedical
emergency.
Water-resistant
personal help button
(60-906-95) a
The water-resistant personal help button is a wireless device used for activating police, medical or
auxiliary alarms through your system. When the help button is pressed, the light mounted under
the cover will blink and an alarm signal is transmitted.
a.
Devices noted have not been investigated for use in UL installations.
CAUTION: Do not use outdoor motion sensors for intrusion protection.
Standard panel
Table 2 describes the basic panel (out-of-box) hardware capabilities.
Table 2.
Panel hardware capabilities
Hardware
Capability
Power
Input for an AC step-down, plug-in style transformer.
One siren output, up to two zone
inputs
Terminals for connecting hardware sirens or normally closed (NC) loop switch circuits.
Phone line connection
Allows panel to communicate with central monitoring station and/or remote phone.
Inspect the package and contents for visible damage. If any components are damaged or missing, do not use the
unit; contact the supplier immediately. If you need to return the unit, you must ship it in the original box. n
Chapter 2 Planning
This chapter provides information to help you plan your installation to reduce
time and costs.
In this chapter:
Planning the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Control panel location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Planning sensor types and locations. . . . . . . . . . . . . . . . . . . . . . . . . .6
System configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Emergency planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
6
Simon XT
Installation Manual
Planning the installation
This section describes system capabilities to help you get familiar with your system. The planning sheets
contain tables that let you record the hardware and programming configuration of your system. Complete all of
the information ahead of time to help prepare for system installation. Refer to Sensor names on page 72 for
sensor name segments listed alphabetically and by index number.
Control panel location
Locate the panel where alarm sounds can be heard and where the panel will be easily accessible for operation.
Do not install the panel near a window or door where it can be reached easily by an intruder.
Planning sensor types and locations
The first step to an easy and successful installation is to decide what areas or items to protect, which lights or
appliances to operate, and the best location for the panel, touchpad, sensors, and sirens.
Metal objects, mirrors, and metallic wallpaper can block signals sent by the wireless sensors. Make sure there
are no metal objects in the way when installing the system.
Use Table 3, Recommended sensor groups on page 7 and Table 4, Sensor group characteristics on page 7 to
determine the appropriate sensor type for the sensors you will be adding. Use Table 5, Sensor assignments/
locations on page 9 to document the planned sensor information. You will need to understand the application
for each sensor. For example, keyfobs are typically programmed as sensor group 01 (portable panic) and used
to send an intrusion alarm to a central monitoring station. This sensor type is instant intrusion, it does not
require restoral or supervisory communication with the panel and it is active in four arming levels:
1. Disarm.
2. Arm doors and windows.
3. Arm motion sensors.
4. Arm doors/windows and motion sensors.
Chapter 2
Planning
Table 3.
Recommended sensor groups
Device
Recommended sensor group
Indoor motion sensor
17 (intrusion), 25 (chime)
Outdoor motion sensor
25 (chime only)
Entry/exit door
10
Interior door
14
Window sensor
13
Smoke Sensor
26
Keyfob
01, 03, 06, 07
ELM keyfob
01, 03, 06, 07
Remote Handheld Touchpad
01, 03, 06, 07
CO Alarm
34
Freeze Sensor
29
Water Sensor
38
Personal Help Button
01, 03
Supervisory
Active In
arming
levels
00 Fixed panic: 24-hour audible fixed emergency button.
Intrusion
1234
01 Portable panic: 24-hour audible portable emergency buttons.
Intrusion
1234
02 Fixed panic: 24-hour silent fixed emergency buttons. Status light will not blink.
Silent
01234
03 Portable panic: 24-hour silent portable emergency buttons. Status light will not
blink.
Silent
01234
04 Fixed auxiliary: 24-hour auxiliary sensor.
Emergency
01234
05 Fixed auxiliary: 24-hour emergency button. Siren shut off confirms CS report.
Emergency
01234
06 Portable auxiliary: 24-hour portable auxiliary alert button.
Emergency
01234
07 Portable auxiliary: 24-hour portable auxiliary button. Siren shut off confirms CS
report.
Emergency
01234
08 Special intrusion: such as gun cabinets and wall safes. DTM (tamper only).
Intrusion
1234
09 Special intrusion: such as gun cabinets and wall safes.
Intrusion
1234
10 Entry/exit delay: A delay that requires a standard delay time. chime.
Intrusion
24
13 Instant perimeter: Exterior doors and windows. chime.
Intrusion
24
14 Instant interior: Interior doors.
Intrusion
234
Type
Siren type
Restoral
Sensor group characteristics
Delay
Table 4.
Name/application
Simon XT
Installation Manual
Siren type
Restoral
Supervisory
Sensor group characteristics (continued)
Delay
Table 4.
Active In
arming
levels
15 Instant interior: Interior PIR motion sensors.a
Intrusion
234
16 Instant interior: Interior doors.
Intrusion
34
17 Instant interior: PIR motion sensors and Sound sensors.a
Intrusion
34
18 Instant interior: Cross-zone PIR motion sensors.
Intrusion
34
19 Delayed interior: Interior doors that initiate a delay before going into alarm.
Intrusion
34
20 Delayed interior: PIR motion sensors that initiate a delay before going into
alarm.a
Intrusion
34
21 Local instant interior: 24-hour local alarm zone protecting anything that opens
and closes. No report.
Intrusion
1234
22 Local delayed interior: same as group 21, plus activation initiates a delay
before going into alarm. No report.a
Intrusion
1234
23 Local instant auxiliary: 24-hour local alarm zone protecting anything that
opens and closes. No report.b
Emergency
01234
24 Local instant auxiliary: 24-hour local alarm zone protecting anything that
opens and closes. Sirens shut off at restoral. No report. a
Emergency
01234
25 Local special chime: notify the user when a door is opened. b
Three beeps
01234
26 Fire: 24-hour fire, rate-of-rise heat, and smoke sensors.c
Fire
01234
27 Lamp control or other customer feature. No report.
Silent
01234
28 PIR motion sensor, sound sensor, or pressure mat. RF thermostat. No report. b
Silent
01234
29 Auxiliary: freeze sensors.
Trouble beeps
01234
32 PIR motion sensor or sound sensor. No report. b
Silent
01234
34 Carbon monoxide alarm.
Emergency
01234
35 Entry/exit delay interior PIR motion.
Intrusion
234
36 Special Intrusion: such as gun cabinets and wall safes. Reports as tamper if
tripped. b
Intrusion
1234
37 Light switch control: X10 modules turn either on or off when a door is opened. b Silent
01234
38 Auxiliary: water sensors. b
Trouble beeps
01234
39 Local instant interior: 24-hour local alarm zone protecting anything that opens
and closes. No report.
Intrusion
1234
40 Local special chime.
Three beeps
01234
Type
a.
b.
c.
Name/application
This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
This type has not been investigated by UL.
This type is required for UL-listed residential fire alarm applications.
Chapter 2
Planning
Table 5.
Sensor assignments/locations
Sensor #
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Device
Sensor
group
Sensor name/location
Notes
10
Simon XT
Installation Manual
Table 5.
Sensor assignments/locations (continued)
Sensor #
Device
Sensor
group
Sensor name/location
Notes
31
32
33
34
35
36
37
38
39
40
Cross-zoning
Cross-zoning (two-trip) refers to two different group 18 sensors that must be tripped within two minutes of
each other to report an alarm to the central station. Figure 2 shows the path of a person walking from the
kitchen to the living room. When the person is detected walking through the kitchen, the motion sensor in the
kitchen is tripped, sounding a local alarm. If motion is detected by the living room motion sensor within two
minutes, an alarm report will be sent to the central station.
Figure 2.
Cross-zone diagram
Motion sensor
Path of
person walking
Motion sensor
Note: We do not recommend cross-zoning for exit/entry zones. Each zone can individually protect the intended area.
Chapter 2
Planning
System configuration
Table 6 is a worksheet for you to record the desired values for each programming option. For each option, the
default value, effect of deletion (pressing DISARM while editing), range, and programming privilege are also
listed. Each option is described in more detail in on page 33.
Table 6.
System programming menu options
Function
Default
Delete
Range
Access
code a
Dealer code
654321, 54321,
4321, or 321
None
3 to 6 digits
Installer code
654321, 54321,
4321, or 321
None
3 to 6 digits
D, I
Master code
123456, 12345,
1234, or 123
None
3 to 6 digits
D, I, M
User code 1
None
None
3 to 6 digits
D, I, M
User code 2
None
None
3 to 6 digits
D, I, M
User code 3
None
None
3 to 6 digits
D, I, M
User code 4
None
None
3 to 6 digits
D, I, M
User code 5
None
None
3 to 6 digits
D, I, M
User code 6
None
None
3 to 6 digits
D, I, M
User code 7
None
None
3 to 6 digits
D, I, M
User code 8
None
None
3 to 6 digits
D, I, M
Duress code
None
None
3 to 6 digits
D, I, M
Code length
3 to 6
Access codes menu
Installer
settings
11
12
Simon XT
Installation Manual
Table 6.
System programming menu options (continued)
Function
Default
Delete
Range
Access
code a
Account number
00000
00000
0 to FFFFFFFFFF
D, I
Downloader code b
12345
12345
00000 to 99999
Phone lock
Off
Off
On/Off
Autoarm (must be added for
UL listed systems)
On
Off
On/Off
D, I
Exit extension (must be
deleted for UL listed
systems)
On
Off
On/Off
D, I
Secure arming
Off
Off
On/Off
D, I
No arm low battery
Off
Off
On/Off
D, I
Quick exit (must be disabled
for UL listed systems)
Off
Off
On/Off
D, I
Downloader enable b
On
Off
On/Off
D, I, M
Supervisory protest b
Off
Off
On/Off
D, I
Phone #1
None
None
26 digits
Phone #2
None
None
26 digits
Phone #3
None
None
26 digits
D, I
Phone #4
None
None
26 digits
D, I, M
Downloader number b
None
None
26 digits
D, I
Manual phone test
On
Off
On/Off
D, I
Fail to communicate (must
be added for UL listed
systems)
On
Off
On/Off
D, I
DTMF
On (Touchtone)
Off (Pulse)
On/Off
D, I
300 bps baud rate
On (300 bps)
Off (110 bps)
On/Off
D, I
Ring/hang/ring b
Off
1 to 7, Off
D, I
Dial delay
30 seconds
15 sec.
15 to 45 sec.
D, I
Call waiting code
None
None
26 digits
D, I
Security menu
Phone # menu
Phone options menu
Installer
settings
Chapter 2
Planning
Table 6.
System programming menu options (continued)
Function
Default
Delete
Range
Access
code a
Sensors menu
Learn sensors
D, I
Delete sensors
D, I
Edit sensors
D, I
Reporting menu
Report options
Opening reports
Off
Off
On/Off
D, I
Closing reports
Off
Off
On/Off
D, I
Forced armed
Off
Off
On/Off
D, I
AC power failure report
(must be added for UL listed
systems)
Off
Off
5 to 254 minutes, Off
D, I
Low CPU battery report
(must be added for UL listed
systems)
On
Off
On/Off
D, I
Sensor alarm restoral report Off
Off
1 to 3, Off
D, I
24-hour sensor tamper
report
Off
Off
On/Off
D, I
Supervisory/tamper report b
Off
Off
On/Off
D, I
No usage b
Off
Off
2 to 254 days, Off
D, I
Swinger shutdown
On
Off
On/Off
D, I
Programming report
Off
Off
On/Off
D, I
Fire alarm verification
Off
Off
On/Off
D, I
Phone 1 report mode
Off
Off
ALL SIA
Phone 2 report mode
Off
Off
Phone 3 report mode
Off
Off
Phone 4 report mode
Off
Off
Report communication
modes
ALL CID
Alarms SIA
Alarms CID
D, I
Nonalarms SIA
D, I
Nonalarms CID
Backup SIA
Backup CID
Voice dialer
Off
Installer
settings
13
14
Simon XT
Installation Manual
Table 6.
System programming menu options (continued)
Function
Default
Delete
Range
Access
code a
Latchkey time b
None
None
12:00 midnight to 11:59 PM,
None
D, I, M
Entry delay (must be 45
seconds for UL listed
systems
30 sec.
30 sec.
30 to 240 sec.
D, I
Exit delay (must be 60
seconds for UL listed
systems)
60 Seconds
45 sec.
45 to 254 sec.
D, I
No activity timeout b
Off
Off
2 to 24 hours
D, I
Auto phone test (must be set
to 1 for UL listed systems)
Off
Off
1 to 254 days
D, I
Supervisory time
Midnight
None
12:00 midnight to 11:59 PM,
None
D, I
Alarm cancel
6 minutes
Off
6 to 255 minutes, Off
D, I
RF timeout (supsync) (must
be set to 4 for UL 985 & 1635
listed systems, or 24 for UL
1023 listed systems)
12 hours
12 hours
2 to 36 hours
D, I
Fail to open time b
Off
Off
12:00 midnight to 11:59 PM,
Off
D, I
Fail to close time b
Off
Off
12:00 midnight to 11:59 PM,
Off
D, I
Siren timeout (must be
greater than 4 minutes for
UL listed systems)
5 minutes
Off - No timeout
2 to 254 minutes, Off
D, I
Arming LED shutdown
Off
Off
On/Off
D, I
Unvacated premises
On
Off
On/Off
D, I
Smoke supervision (must be
disabled for UL listed
systems)
Off
Off
On/Off
D, I
Keyfob no delay b
Off
Off
On/Off
D, I
Panic alarms b
On
Off
On/Off
D, I
Remote touchpad arming b
Off
Off
On/Off
D, I
Timers menu
Touchpad options menu
Installer
settings
Chapter 2
Planning
Table 6.
System programming menu options (continued)
Function
Default
Delete
Range
Access
code a
RF Jam detect (must be
added for UL listed systems)
Off
Off
On/Off
D, I
Demo mode b
Off
Off
On/Off
D, I
HW1 function
Off
1 - Interior siren output
System options menu
2 - Output activated when
armed
3 - Output activated when
disarmed
4 - FTC output (FTC must be on)
5 - Output activated for alarm
Off - No output
24-hour clock
Off
Off
On/Off
D, I
Panel piezo beeps (must be
on for UL listed systems)
On
Off
On/Off
D, I, M
Panel voice
On
Off
On/Off
D, I, M
Panel piezo alarms (must be
added for UL listed systems
or a siren must be
connected
On
Off
On/Off
D, I, M
Trouble beeps (must be
added for UL listed systems)
On
Off
On/Off
D, I
Voice chime
Off
Off
Off - No voice chime
D, I
Siren options menu
1 - Voice chime (sensor name)
2- Chime bell
3- Soft chime bell
Status beeps volume
1 - 10
D, I, M
Hardwired siren supervision
Off
Off
On/Off
D, I
Speaker volume
1 to 8
D, I, M
Panel silent police panic
Off
Off
On (silent), Off (audible)
D, I
Panel tamper alarm
Off
Off
On/Off
D, I
Alarm report verification
Off
Off
On/Off
D, I
Installer
settings
15
16
Simon XT
Installation Manual
Table 6.
System programming menu options (continued)
Function
Default
Delete
Off
Off
Range
Access
code a
Off - Audio mode disabled
D, I
Audio verify menu
Audio mode b
1 - Instant mode
2 - Callback mode
Fire shutdown b
Off
Off
On/Off
D, I
Panic talk
Off
Off
On/Off
D, I
Vox receiver gain b
1 to 32
D, I
Vox mic gain b
24
24
1 to 64
D, I
Vox mic gain range b
64
64
1 to 64
D, I
Manual mic gain
64
64
1 to 64
D, I
Set entry lights b
Off
Off
On/Off for each unit number
from 1 to 8
D, I, M
Sensor light b
Off
Off
1 to 8, Off
D, I, M
Light schedule b
None
None
HH:MMx for start and stop
times, None
D, I, M
Housecode b
A to O
D, I, M
Lock interval b
None
None
HH:MMx for start and stop
times, None
D, I, M
Light control menu
System test menu
Sensor test
D, I, M
Communication test
D, I, M
System download b
D, I, M
a.
b.
This column tells what type of access code is allowed to make changes: D = dealer code, I = installer code, M = master code.
Not investigated for use by UL.
Emergency planning
Use these guidelines when drawing an emergency floor plan for the homeowner:
•
•
•
•
Show all building levels.
Show exits from each room. (We recommend two exits per room.)
Show the locations of all security system components.
Show the locations of any fire extinguishers.
Installer
settings
Chapter 3 Installing the system
This section describes how to open the panel for mounting, mount the panel,
connect sirens, connect hardwired contacts, and connect the AC power
transformer.
In this chapter:
Opening panel cover and chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Mounting the panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Connecting hardwired devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
HW1 I/O, HW2 in, and HW1&2 DC out terminals. . . . . . . . . . . . . .24
Interior sirens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
LD105 hardwired interior siren . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Hardwired contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Wiring a phone line to the panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Full line seizure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Wiring the power transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Powering up the panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Installing X10 modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
18
Simon XT
Installation Manual
UL listed installations
Some installations may require configurations dictated by city/state codes, insurance, or Underwriter’s
Laboratories (UL). This section describes the various component and configuration listings.
Basic system:
•
•
•
Control panel: backup battery 6 V 1.2 Ah (34-025) (Portalac model # PE6V1.2)
Standard class 2, 9 VAC, 3.34 A power transformer (GE model # 22-153).
Hardwired siren (13-374)
Household burglary alarm system unit (UL 1023), basic system plus the following:
•
•
•
•
•
•
•
•
•
•
•
•
•
Hardwired magnetic contact (13-068 or 13-071) or wireless learn mode door/window sensor (60-670)
Panel piezo beeps set to on
Entry delay set to 45 seconds or less
Exit delay set to 60 seconds or less
RF time-out set to 24 hours
Control panel alarms turned on
Autoarm set to on
Siren timeout set to five minutes or more
Trouble beeps set to on
RF jam detect set to on
Hardwired siren supervision set to on
Exit extension set to off
Quick exit set to off
Household fire warning system (UL 985), basic system plus the following:
•
•
•
•
•
•
•
•
Wireless smoke sensor 60-848-95 learned into sensor group 26
Panel piezo beeps turned on
Control panel alarms set to on
Siren timeout set to four minutes or more
Trouble beeps set to on
RF jam detect set to on
Hardwired siren supervision set to on
Smoke supervision must be set to on
UL 1023 & 985 24-hour backup:
•
For 24-hour backup, the total current draw for all connected devices is limited to 250 mA (during
normal standby conditions) using a 1.2 AH battery.
UL 1635 digital alarm communicator system:
•
Same as UL 1023 & 985, plus:
Chapter 3
Installing the system
The following settings are in addition to UL 1023 and 985 and are required only if the system is set up for
central station reporting.
•
•
•
•
•
•
•
Phone mod 1 set to zero or one.
Automatic phone test set to 001.
RF timeout set to four hours.
AC power failure report set to on.
CPU low battery report set to on.
Fail to communicate set to on.
Entry delay plus the dialer delay must not exceed 60 seconds.
SIA system requirements
SIA system requirements are the same as those described for a UL listed basic system on page 1, plus:
•
If multiple annunciation is required, use hardwired siren part no.13-046.
Note: UL requirements take priority over SIA requirements. Entry delay must not exceed 60 seconds.
SIA setting requirements
Table 7 describes programming requirements to meet ANSI-SIA CP-01 (see System programming on page 39).
Note: Call waiting services should be disabled to prevent interrupting panel communication to the central monitoring station..
Table 7.
SIA setting requirements
Function
Programming page
reference
Default setting
Required setting
Entry delay
Table 20 on page 49
30 seconds
30 to 240 seconds
Exit delay
Table 20 on page 49
60 seconds
45 to 240 seconds
Dialer delay
Table 15 on page 43
30 seconds
15 to 45 seconds
Autoarm
Table 13 on page 41
On
On
Unvacated premises
Table 20 on page 49
On
On
Call waiting
Table 15 on page 43
Off
On if reporting to central station and
customer has call waiting service
Exit extension
Table 13 on page 41
On
On
Swinger shutdown
Table 18 on page 47
On (one trip)
On (one trip)
Fire alarm verify
Table 18 on page 47
Off
On
Duress/panic code
Table 23 on page 52
Disabled
Disabled
Cross zone
Cross-zoning on
page 10
Disabled
Disabled for zones with high probability of
false alarms.
19
20
Simon XT
Installation Manual
Table 8 describes nonprogrammable (hard-coded) system operation, as required to meet ANSI-SIA CP-01, and
is provided only for your reference.
Table 8.
Nonprogrammable (hard coded) system operation
Function
Operation
Silent exit
All annunciators enabled
Remote arming exit time and
progress annunciation
All annunciators enabled
Abort annunciation
Enabled
Cancel report annunciation
Enabled
Recent closing
Enabled (2 minute window)
Exit error
Enabled
Restoration of power
Panel resumes operation in same arming state and disregards alarm signals from sensors
for the first 60 seconds after power restoration
Cancel alarm
Enter code only.
Central station reporting
The panel has been tested with the following central station receivers using SIA and Contact ID reporting
formats:
Note: Before beginning installation, installers must verify compatibility with the following central station receivers.
•
•
•
Radionics D6600 central station receiver
Sur-Gard central station receiver with models SG-DRL2A and SG-CPM2
CS5000 digital alarm communicator receiver
UL Canada listed installations
This section describes the requirements for CUL (UL Canada) listed installations.
Canadian standards CSA certified accessories
Standard Class 2, 9 VAC, 3.34 A power transformer (GE Security model 22-153-CN).
Residential burglary alarm system unit (ORD-C1023-1974)
Basic system as described for UL 1023 listed installations plus:
•
•
Hardwired magnetic contact (13-068 or 13-071) or wireless learn mode door/window sensor (60-670)
Siren timeout set to six minutes or more
Chapter 3
Installing the system
Residential fire warning system control unit (ULC-S545-M89)
Basic system as described for UL 985 listed installations plus:
•
•
•
Wireless smoke sensor 60-848-95 learned into sensor group 26
Siren timeout set to six minutes or more
For 24-hour backup, the total current draw for all connected devices is limited to 250 mA (during
normal standby conditions) using a 1.2 AH battery.
California state fire marshall listed installations
Applied for.
21
Simon XT
Installation Manual
Opening panel cover and chassis
Tabs at the top of the panel secure and release the front cover and the chassis. The plastic hinges on the panel
bottom allow the cover and chassis to swing down and out of the way (Figure 3).
Figure 3. Opening the panel cover and chassis
Back piece
Hinge
Hinge
Pb
22
Chassis
Tabs
Chapter 3
Installing the system
Mounting the panel
To mount the panel on a wall, do the following:
1. Choose a panel location.
2. Run all necessary power, phone, siren, and hardwired contact wires to the desired panel location.
Note: When choosing the AC outlet location for the AC power transformer, make sure the outlet is not controlled by a
switch or that it is not part of a ground fault circuit interrupt (GFCI).
3. Hold the panel against the wall and mark the mounting hole locations with a pencil.
4. Mount the back piece to the wall through the two horizontally centered mounting holes near the top
and bottom using the supplied mounting hardware. Use wall anchors if no studs are present (Figure 4).
Figure 4. Panel mounting hole locations
Mounting hole
Back piece
Mounting hole
5. Connect the chassis assembly to the mounted back piece and let it hang down. This makes the
terminal strip accessible for wiring various hardwired components to the panel.
6. Feed wires through openings in the back piece to be ready to attach them to the screw terminals or the
phone connectors.
7. Install all screws and tighten gently.
23
24
Simon XT
Installation Manual
Connecting hardwired devices
The panel has seven screw terminals and two telephone connections (Figure 5). The screw terminals connect
AC power, sirens, and/or hardwired detectors.
Program sensors and devices before you install them. Follow the instructions in to add the sensors to panel
memory.
Figure 5. Simon XT terminal connections
HW2 in
HW1&2 DC out
HW1 I/O
9 VAC in
Battery + pos
Battery – neg
RJ45 connector (LINE)
RJ11 connector (PHONE)
Battery compartment
Tamper switch
HW1 I/O, HW2 in, and HW1&2 DC out terminals
The HW1 I/O terminal is dual purpose and can be used for either siren or hardwired contact connections. The
HW2 in terminal is an input only.
Interior sirens
From the factory, the HW1 I/O input is set up for interior siren operation (status and alarm sounds). HW1&2
DC out provides the positive (+) voltage.
Note: The total current available from the HW1&2 DC out terminal is 250 mA at up to 120°F (49°C). A 24-hour battery standby for
UL Requirements will be met with a maximum load of 250 mA.
With Hardwired Siren Supervision turned on, sirens connected to HW1 I/O are supervised and require a
4.7 kohm resistor in the circuit. If this terminal is not used, turn Hardwired Siren Supervision off.
Chapter 3
Installing the system
LD105 hardwired interior siren
Interior sirens must always be wired with a resistor in the circuit. For circuit supervision which allows the
panel to detect if the siren wire is cut (open), Hardwired Siren Supervision must be turned on. (See on
page 33).
Note: Do not install the resistor at the panel terminals. This does not provide supervision of the wire.
Connect the LD105 hardwired interior siren (13-374) to the panel using a 4.7 kohm resistor (included with the
siren) as shown in Figure 6. The resistor must be connected across the siren wires as close to the siren as
possible.
Figure 6. Hardwired interior siren with supervision
4.7 kohm resistor
(located at siren)
Black
Battery -
Battery +
9 VAC in
9 VAC in
HW2 in
HW1&2
DC out
HW1 I/O
Red
Hardwired contacts
To set up HW1 I/O and/or HW2 in for hardwired contacts, make the required connections as described under
below, then proceed to the Programming on page 33 to add (learn) them into panel memory.
You can connect hardwired reed switches (normally closed loop only) to HW1 I/O (if not being used for a
hardwired siren) and/or HW2 in.
Note: Connect only normally closed (NC) reed switches to HW1 I/O and/or HW2 in. Other types of hardwired detectors should
not be used.
The total resistance of the wire loop must not exceed 3 ohms. This allows you to use up to 200 ft. (61 m) of
two-conductor, 22-gauge stranded wire.
Connect hardwired reed switches to the panel using a 47 kohm resistor (not a 4.7 kohm resistor) as shown in
Figure 7. The resistor must be connected at the last switch in the circuit.
25
Simon XT
Installation Manual
Note: Do not install the resistor at the panel terminals. This does not provide supervision of the wire.
Figure 7. Connecting normally closed hardwired reed switches
Battery -
Battery +
9 VAC in
9 VAC in
HW2 in
HW1&2
DC out
47 kohm resistors
HW1 I/O
26
Chapter 3
Installing the system
Wiring a phone line to the panel
You can connect a phone line to the panel for systems monitored by a central monitoring station or systems that
notify users by a voice event notification.
DSL (digital subscriber line) allows the use of multiple devices on a single phone line simultaneously. For
DSL environments, connect the panel line-in jack to an available phone jack on the premises. You might also
need an inline filter to ensure panel reporting is successful.
Note: Avoid connecting the panel to a standard phone (voice) line in this manner. Other devices in use at the same time the
panel is using the line can prevent reports from going through.
Full line seizure
Full line seizure allows the panel to take over (seize) the phone line, even if another device on the line is in use.
This method requires that the panel be wired before all other phones, answering machines, computers, or other
devices on the phone line. You may need to verify line seizure for UL installations.
Use the RJ31X (CA-38A) jack (Figure 8 on page 28) when wiring for full line seizure. This lets the user
quickly and easily disconnect the panel from the phone line in case the panel disables the phone line due to a
malfunction.
Full line seizure wiring with an RJ31X
1. Run a four-conductor cable A from the premises Telco block D to the RJ31X B.
2. Connect the four-conductor cable A wires to the RJ31X B.
3. Disconnect the green and red premises phone jack wires from the Telco block D and splice them C to
the four-conductor cable A black and white (or yellow) wires. Use weatherproof wire connectors for
these splices.
4. Connect the four-conductor cable A green and red wires to the Telco block D TIP (+) and red to RING
(–) posts.
5. Connect the phone cord E included with the panel to the RJ31X B and the panel LINE jack.
27
Simon XT
Installation Manual
Figure 8. Full line seizure wiring with RJ31X
BRN
Pb
GRY
Red
Green
White
(or Yellow)
RED
GRN
Black
28
TIP RING
(+) (-)
Green
Red
Black
White (or Yellow)
Green
Red
Full line seizure wiring with one premises phone
If a single phone is all that exists on the premises, full line seizure can be accomplished without an RJ31X
(Figure 8 on page 29).
Chapter 3
Installing the system
1. Disconnect the phone from the premises phone jack and plug it into the panel PHONE jack A. This
jack is disconnected automatically whenever the panel reports.
2. Connect the included phone cord to the panel LINE jack and the premises phone jack B.
Note: If customers add phones or other phone devices to another phone jack, full line seizure no longer exists. Inform them to
contact you if they want to add a phone or other device so that you can rewire for full line seizure by adding an RJ31X.
Figure 9. Full line seizure wiring with single landline phone
Line premises phone
Pb
Premises phone jack
29
Simon XT
Installation Manual
Wiring the power transformer
Connect the power transformer to the panel AC terminals as shown in Figure 10.
Battery -
Battery +
9 VAC in
9 VAC in
HW2 in
HW1&2
DC out
Figure 10. Transformer connections
HW1 I/O
30
Note: Do not plug in the transformer at this time
Powering up the panel
When applying power to the panel connect the battery first, then plug in the AC power transformer. This
sequence prevents a battery fault condition.
Note: Maximum battery charge current is 60 mA. It may take up to 24 hours for a new battery to fully charge.
Installing the backup battery
To install the backup battery (6 VDC, 1.2 Ah), do the following:
1. Connect the lug end of the red battery lead to the red battery tab.
2. Connect the lug end of the black battery lead to the black battery tab.
3. Align the red (+) battery terminal with the right end of the terminal strip. The logo and specification
information should be readable.
4. Insert the front end of the battery under the forward battery compartment latch.
5. Push forward and rotate the battery downward until it seats beneath the rear battery compartment latch.
CAUTION: Do not connect the battery until you are ready to power up the panel. See Powering up the panel on page 30.
Chapter 3
Installing the system
Figure 11. Installing the panel backup battery
Pb
Applying AC power
Make sure the outlet is not controlled by a switch or that it is not part of a ground fault circuit interrupt (GFCI).
1. Remove the center screw from the outlet cover plate and hold the cover plate in place.
WARNING: Use extreme caution when securing the transformer to a metal outlet cover. You could receive a serious
shock if a metal outlet cover drops down onto the prongs of the plug.
2. Plug the transformer into the lower receptacle of the outlet so that the hole in the transformer tab lines
up with the outlet cover screw hole.
3. Insert the cover plate screw through the transformer tab and the outlet cover plate. Tighten the screw.
31
32
Simon XT
Installation Manual
Installing X10 modules
To install lamp and appliance modules, do the following:
1. Set the unit code dial to a unit number between 1 and 8.
2. Set the housecode for the installation.
3. Plug the module into a wall outlet.
4. Plug the lamp/appliance into the module.
CAUTION: Do not plug in appliances or lamps with 300-watt or larger bulbs into Lamp Modules
To install universal modules, do the following:
1. Set the unit code dial to a unit number different from all other X10 modules (between 1 and 8).
2. Set the housecode for the installation.
3. Set the module switches to momentary and relay only.
4. Connect the module terminals to the desired device terminals.
5. Plug the universal module into a wall outlet.
Chapter 4 Programming
This chapter provides steps on how to program your unit.
In this chapter:
Programming overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Entering and exiting the system menu . . . . . . . . . . . . . . . . . . . . . . .35
Menu navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Set clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Revision. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Contrast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
System programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Access codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Phone numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Phone options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Reporting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Touchpad options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
System options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Siren options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Piezo beep options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Audio verification options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Light control (optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
System tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Resetting memory to the factory defaults . . . . . . . . . . . . . . . . . . . . . . . .58
34
Simon XT
Installation Manual
Programming overview
The control panel Figure 12 provides the main processing unit for all system functions. The programming of
system options and features is menu-driven. All installer options are set in the System Programming menu,
except for setting the system time. Table 9 on page 35 explains the panel keys and features shown in Figure 12.
Figure 12. Simon XT self-contained panel
MOTIONS
DOORS+WINDOWS
Piezo siren
DISARM
STATUS
Scroll up
Enter
Scroll down
LCD display
SILENT
BYPASS
Emergency
Police
Number keypad
Speaker
Microphone
Fire
Lights on
Lights off
Door
Chapter 4
Programming
Table 9.
Simon XT panel keys and features
Control
Description
Piezo siren
The piezo siren makes alarm beeps and status beeps. Fire and intrusion alarm beeps are always
played at high volume, while the volume of status beeps (such as trouble or chime beeps, entry and
exit delay beeps, or auxiliary alarm beeps) is programmable.
LCD display
The LCD module has a 2 x 16 character array that displays a variety of phrases and icons.
DOORS + WINDOWS
Press to arm perimeter sensors.
MOTIONS
Press to arm interior sensors.
DISARM
Press to turn off intrusion/burglary protection for your system. Only intrusion/burglary sensors such as
doors, windows, and motion sensors are disarmed. Environmental sensors, such as smoke and carbon
monoxide, stay active at all times.
STATUS
Press to determine system status.
SILENT
Press to silence exit beeps when arming.
BYPASS
Press to bypass a sensor.
Police
Press and hold the Police button for two seconds (or press twice quickly) to call the central monitoring
station and notify them of a nonmedical call for help.
Emergency
Press and hold the Emergency button for two seconds (or press twice quickly) to call the central
monitoring station and notify them of a nonmedical call for help.
Fire
Press and hold the Fire button for two seconds (or press twice quickly) to call the central monitoring
station and notify them of a nonmedical call for help.
Microphone
Used to communicate with central monitoring station after an alarm.
Scroll up/scroll down
Press to scroll through lists of similar items.
Enter
Press to select a particular menu item or commit to memory a menu item that has just been
programmed.
Numeric keypad
Twelve-key telephone-type keypad (0 through 9, *, #) for entering access codes or other numerical
data.
Speaker
Provides voice output and sounds key beeps. The panel speaks arming level changes, system status,
and voice chime sensor trips. The panel voice is also used for voice reporting and remote phone
control.
Door
Covers the lower panel.
Lights on.
Lights off.
Entering and exiting the system menu
To enter the system menu, press either the scroll up/down or enter buttons in the upper right of the panel.
Press the STATUS button to exit a menu or option edit mode and navigate up one level. Pressing the STATUS
button while in the top menu level exits the system menu level. The panel automatically exits the system menu
after a few seconds of inactivity if no access code has been entered yet. After an access code has been entered
to access a code-protected area of the system menu, the timeout is 4 minutes.
35
36
Simon XT
Installation Manual
Menu navigation
Each menu contains a list of options and/or submenus. Press the scroll up/down buttons to navigate up and
down the list of options and submenus in that menu. Pressing the Enter key after navigating to an option
selects that option for editing and flashes the current value. Pressing the Enter key after navigating to a
submenu enters that submenu, making a new list of options accessible. Pressing STATUS exits a menu and
goes to the next higher level.
Programming options are arranged in a menu structure as outlined in Table 10. The top menu contains several
features, as well as the System programming menu. When accessing the System programming or System tests
menu, the panel prompts you to enter an access code. To continue, enter the dealer code or installer code, then
press Enter.
To program an option, first navigate to that option until it is displayed, then press Enter. The option value will
start flashing, indicating that it is ready to be changed. Use the scroll keys or enter a numerical value to change
the option, then press the Enter key to save the change.
Table 10. Simon XT menu structure
System time
Security
Enable scheduled lights
Account number
Enable sensor-activated lights
Downloader code
Enable chime
Phone lock
Enable special chime
Autoarm
System tests
Exit extension
Sensor test
Secure arming
Communication test
No arm on panel low battery
Initiate download call
System programming
Access codes
Dealer code
Quick exit
Downloader enable
Supervisory protest
Phone #s
Installer code
Phone #1
Master code
Phone #2
User code 1
Phone #3
User code 2
Phone #4
User code 3
Downloader phone number
User code 4
Phone options
User code 5
Manual phone test
User code 6
Fail to communicate
User code 7
DTMF dialing
User code 8
300 bps baud rate
Duress code
Ring/hang/ring
Code length
Dialer delay
Call waiting code
Chapter 4
Programming
Table 10. Simon XT menu structure (continued)
Sensors
System options
Learn sensor
RF jam detect
Delete sensor
Demo mode
Edit sensor
HW1 I/O
Reporting
Report options
24-hour clock format
Siren options
Opening report
Panel piezo beeps
Closing report
Panel voice
Force armed report
Panel piezo alarms
AC power failure report
Trouble beeps
Panel low battery report
Voice chime
Sensor alarm restoral report
Status beep volume
24-hour sensor tamper
Hardwired siren supervision
Supervisory/tamper report
Speaker volume
No usage report
Panel silent police panic
Swinger shutdown
Panel tamper
Programming report
Fire alarm verification
Alarm report verification
Audio verification
Communication modes
Audio mode
Phone 1 reports
Fire shutdown
Phone 2 reports
Panic talk
Phone 3 reports
VOX receiver gain
Phone 4 reports
VOX microphone gain
Timers
VOX gain range
Latchkey time
Entry delay
Manual microphone gain
Light control
Exit delay
Set entry lights
No activity timeout
Sensor lights
Auto phone test
Light schedules
Supervisory time
Housecode
Alarm cancel window
RF timeout
Lock interval
System tests
Fail to open time
Sensor test
Fail to close time
Communication test
Siren timeout
Initiate download call
Arming LEDs shutdown
Revision
Unvacated premises
Contrast
Smoke sensor supervision
Touchpad options
Keyfob no delay
Panel panic alarms
Remote touchpad arming
37
38
Simon XT
Installation Manual
Set clock
If the panel loses both AC and battery power, then upon restoring power the system time will reset to midnight
and blink, indicating it has not been set correctly. You can set the system time to display in either 12-hour or
24-hour format.
Time of day format is HH:MMx, where:
HH = 01 to 12 (12-hour format) or 00-23 (24-hour format)
MM = 00 to 59
x = a or p (12-hour format) or none (24-hour format)
To reset the clock:
1. Scroll up/down until the display shows Set clock.
2. Press Enter.
3. The display shows Enter code.
4. Enter your code with numeric keys. Press Enter.
5. Press Enter. The display now flashes the hours.
6. Scroll up/down to set the hours.
7. Press the Enter key to accept. The display now flashes the minutes.
8. Scroll up/down to set the minutes.
9. Press the Enter key to accept. The display is now flashing the AM/PM.
10. Scroll up/down to set the AM/PM.
11. Press Enter to accept. The display now shows the current time, and stops flashing.
12. Press the STATUS button twice to exit.
Revision
To display the firmware revision of the system:
1. Scroll up/down to Revision.
2. Press the STATUS button to exit.
Contrast
To adjust the Contrast of the display:
1. Scroll up/down to Contrast.
2. Press the Enter button.
3. Scroll up/down to increase and decrease the contrast setting.
4. Press the STATUS button to save the setting and exit.
Note: Changes in contrast are more noticeable when not looking at the display straight-on.
Chapter 4
Programming
System programming
To enter system programming mode, do the following:
1. Press the scroll buttons until the panel displays System programming.
2. Press Enter. The system prompts for an access code.
3. Enter the access code from the codes listed in Table 11. The system displays each entered access code
digit as an asterisk.
4. Press Enter. The panel is now in program mode.
Note: Do not remove panel power while in program mode.
Table 11. Simon XT programming codes
Code
Description
Dealer code
You can use the dealer code to program all system options, including high-security options that are not
accessible with the installer code if it is different from the dealer code. Depending on how the access code
is set, the default dealer access code is 654321, 54321, 4321 (factory default), or 321. This code can be used
for all programming.
Installer code
Depending on how the access code is set, the default installer code is 654321, 54321, 4321 (factory
default), or 321. This code is limited to changing all but the following: Dealer code, Code length, Downloader
code, Phone lock, Phone #1, Phone #2, Phone 1 report mode, Phone 2 report mode, HW 1 function.
39
40
Simon XT
Installation Manual
Access codes
Table 12. Access codes
Function
Default
Description
Dealer code
4321
You can use the dealer code to program all system options, including high-security
options that are not accessible with the installer code if it is different from the dealer
code. Changing the dealer code to differ from the installer code will prevent the installer
from viewing certain fields.
1. Change the dealer code.
2. Enter program mode with the installer code.
3. Installer should no longer be able to see the following:
Code length, Downloader code, Phone lock, Phone #1, Phone #2, Phone 1 report mode,
Phone 2 report mode, HW1 function.
Installer code
4321
You can use the installer code to program most installer options, except for highsecurity dealer options.
Master code
1234
Master arm/disarm code.
Master code able to enter user programming and bypass sensors.
User codes 1 to
Blank
Regular arm/disarm code.
Duress code
Blank
Use in place of master or user code to cause a silent alarm.
Code length
Four digits
Code can be three to six digits long.
Chapter 4
Programming
Security
Table 13. Security
Function
Default
Description
Account number 00000
Lets you program up to a 10-character alphanumeric account number or delete an
existing account number by pressing DISARM. You can enter numerical digits
sequentially. To enter letters (A to F only), use the scroll buttons to select A to F then
press Enter. To select next digit, press another number key. When finished press Enter.
The CID format only supports account numbers with letters B through F, or numbers 0
through 9 (or a combination of those letters and numbers).
Downloader
code a
12345
Lets you set a unique five-digit code that is required for initiating Enterprise Downloader
sessions. The code must be five digits long and can range from 00000 to 99999. The
downloader code must match the downloader access code in the Enterprise account to
perform Enterprise sessions.
Phone lock
Off
Prevents resetting of phone/reporting related options when a memory clear is
performed (on) or resets these options to their default values when a memory clear is
performed (off).
The following are not reset when on:
• Account number
• Dealer code
• Code length
• Call wait cancel
• Phone numbers 1 and 2
• Phone report modes 1 to 4
• Phone lock
• Downloader phone number
• Downloader code
Autoarm
On
Determines how long the system protests (announces open/failed sensors) when
attempting to arm with open/failed sensors, before bypassing these sensors and
automatically arming the rest of the system.
Note: The panel protests an arming attempt when it has not received a restore (close)
signal from sensors learned into restore-specific sensors groups. Sensors learned
into group 26 (fire) cannot be bypassed.
When this option is on, the panel announces all open/failed sensors repeatedly for 4
minutes, then automatically bypasses the open sensors and arms the rest of the
system. If a sensor is opened during the exit delay and then left open, the panel will go
into alarm after the exit delay has expired.
This option must be on for Unvacated premises and Exit extension to work correctly.
When this option is off, the panel displays all open/failed sensors once, then
automatically bypasses the open sensors and arms the rest of the system after the exit
delay has expired. If other sensors are opened during the exit delay, they will also be
bypassed if left open.
Note: If group 13 (Instant Perimeter) sensors are opened during the exit delay, the panel
goes into immediate alarm.
41
42
Simon XT
Installation Manual
Table 13. Security (continued)
Function
Default
Description
Exit extend
On
Determines whether the panel restarts the exit delay time if the user enters the armed
premises during the initial exit delay period (on), or not (off). Turning on this feature
allows users to reenter during the exit delay period, without disarming and then
rearming the system. Turning off this feature requires the user to disarm and rearm the
system.
Note: Autoarm must be on for this option to work.
Secure arming
Off
Determines whether an access code is required when arming the system (on) or not
(off). This option does not affect keyfob arm/disarm operation.
No arm on low
battery
Off
Determines whether the system protests arming if a low CPU battery condition exists
(on) or not (off).
Quick exit
Off
Determines whether pressing DISARM when the system is armed activates the exit
delay time to allow exit and reentry without disarming the system (on) or not (off).
This feature is useful if the user wants to step outside briefly and return, such as to get
the paper. If the system is armed and the user presses DISARM, the panel announces
Exit time is ON and sounds exit delay beeps. This allows a designated entry/exit door to
be open for up to 2 minutes without causing alarm. When the door is closed, the beeps
stop and the door is armed again.
Note: For UL listed systems, Quick Exit must be Off.
Downloader
enable a
On
Enables programming of system options with downloader software.
Sup protest a
Off
Determines whether the panel protests arming if it has not received a supervisory
signal from any sensor 15 minutes before arming (on) or not (off).
Note: This feature must be turned off for US installations.
a.
Not investigated for use by UL.
Chapter 4
Programming
Phone numbers
Table 14. Phone numbers
Function
Default
Description
Phone # 1
Blank
Phone # 2
Blank
Lets you program up to a 26-digit central monitoring station receiver/voice event
notification phone number for monitored systems. Phone digits can be 0-9, *, #, or a
pause (P).
Phone # 3
Blank
Phone # 4
Blank
To delete the phone number, press DISARM while editing a phone digit. To add a pause
to the phone number press BYPASS. Pressing Enter is required if you enter fewer than 26
digits.
Downloader # a
Blank
Lets you program up to a 26-digit phone number for the Enterprise Downloader.
a.
Not investigated for use by UL.
Phone options
Table 15. Phone options
Function
Default
Description
Man phone test
On
Determines whether the user can perform a manual communication test to verify
communication to a central station/voice dial (on), or not (off). If you have all 4 phone #
programmed it should send a test report to all 4 before showing that test is okay.
FTC
On
Determines whether the panel and interior sirens sound trouble beeps if it is unable to
successfully send a report to a central station (on) or not (off).
DTMF dial
On
Determines whether the panel uses DTMF (on) or pulse (off) for dialing programmed
phone numbers.
300 bps enabled On
Determines whether the baud rate used by the panel for central station communication
is 300 bps (on) or 110 bps (off).
43
44
Simon XT
Installation Manual
Table 15. Phone options (continued)
Function
Default
Description
Ring hang ring a
Determines when the panel answers a remote phone access or Enterprise call.
Depending on whether an answering machine exists at the panel location, offsite
access to the panel can be done with a series of phone calls or just one. For offsite
access where an answering machine does not exist, the user or Enterprise operator
simply calls the panel location once and listens for 10 rings. The panel should answer
after the tenth ring.
For offsite access where an answering machine exists, the user or Enterprise operator
must perform the following steps:
• Call the panel location.
• Let the phone ring once, then hang up.
• Wait at least 10 seconds but not more than 40, then call the panel location again.
The panel should answer on the first ring.
Ring/hang/ring setting number and sequence of rings after which the panel answers:
Ring/hang/ring or ten rings
Ring/hang/ring/hang/ring or ten rings
Ring/hang/ring/hang/ring/hang/ring or ten rings
Ten rings
Ring/hang/ring
Ring/hang/ring/hang/ring
Ring/hang/ring/hang/ring/hang/ring
Off Disabled—no remote (offsite) access
Dial delay
30 seconds
Determines whether the panel delays dialing programmed phone numbers before
sending reports (on).
If Opening (Disarming) Reports is on, the panel
does not delay dialing if the system is disarmed before the delay time expires. The panel
dials immediately for both the alarm and opening report.
Note: Regardless of this option setting, the panel always dials immediately for fire
alarms, AC power failure and low battery reports.
The combined dialer delay and entry delay cannot exceed 60 seconds for a UL Listed
installation.
Call wait code
Off
The call waiting code is dialed by the panel before a phone number to disable call
waiting. Verify that the end-user has call waiting with his phone service provider before
changing this option from its default.
CAUTION: Changing this option from its default without call waiting will prohibit
the panel from calling the central station.
The call waiting code is programmed the same way as a phone number.
a.
Not investigated for use by UL.
Chapter 4
Programming
Sensors
These instructions tell how to add (learn) sensors, touchpads, and other system devices into panel memory. The
panel recognizes a sensor when you press a sensor program button, press and release a tamper switch, press a
sensor test button, or put a sensor into alarm. Table 16 describes the programming method for each device.
Note: If you are installing a sensor on a gun case, jewelry box, or a similar case, and the sensor is active in level one, you must
subdisarm to avoid putting the panel into alarm when the sensor and the magnet are separated.
Table 16. Device programming
Device
To program
Door/window sensor
Press the button on the top of the sensor (cover removed) or trip the tamper.
Motion sensor
Press the button on the back of the sensor (mounting plate removed) or trip the tamper.
Smoke detector
Trip the tamper, press the test button, remove the detector from its base, or put the
smoke detector in alarm.
Hardwired sensor
Separate the sensor from its magnet.
CO alarm
Plug in the module wait 5 to 7 seconds press and hold the test button for nine beeps
Freeze and water sensor
Trip the tamper or press and hold the button on the top of the sensor (cover removed)
until the control panel confirms programming. If you do not hold the button down long
enough, the system will report the sensor as open.
Personal help button
Press the help button until the light blinks.
Remote handheld touchpad
Press the emergency buttons.
Keyfob
Press the lock and unlock buttons at the same time.
ELM keyfob
Do the following:
1.
Press the unlock button twice and hold it the third time. The light button flashes
three times.
2.
Press the unlock button once and hold it the second time. The light button
flashes twice.
3.
Press and hold the unlock button. The light button flashes once. Hold the
button until the flashing stops.
When learning sensors, the panel uses an ascending number sequence starting with 1. You can override this by
entering the desired sensor number using the number keys.
Learning sensors
To learn a sensor:
1. Press the scroll buttons until the panel displays System programming.
2. Press Enter. The system prompts for an access code.
3. Enter the dealer or installer code and press Enter. The panel displays Access codes.
4. Press the scroll buttons until the panel displays Sensors.
5. Press Enter. The panel displays Learn sensor.
45
46
Simon XT
Installation Manual
6. Press Enter. The panel displays Trip sensor ##, with the number signs flashing.
Note: If you wish to use a sensor number other than the next one available, use the number keys to enter a two-digit
sensor number immediately.
7. Press the sensor program button or release the sensor tamper switch. The panel displays Sn ## Grp 10
, with the Grp 10 flashing. Use the number or scroll buttons if you want to enter a new
group number; press Enter to accept the group number displayed.
8. The sensor text is now flashing. Use the scroll buttons to scroll through the text list or enter the threedigit shortcut. (See Table 38 on page 72 and Table 39 on page 73 for these three-digit codes). Press
Enter to accept the first text segment. You may enter more text or press Enter again to finish adding
the sensor.
9. The panel displays Trip sensor ## (with the next available sensor number). Press STATUS repeatedly
to exit.
Deleting sensors
To delete a sensor:
1. Press the scroll buttons until the panel displays System programming.
2. Press Enter. The panel displays Enter code.
3. Enter your access code and press Enter. The panel displays Access codes.
4. Press the scroll buttons until the panel displays Sensors.
5. Press Enter. The panel displays Learn sensor.
6. Press the scroll buttons until the panel displays Delete sensor.
7. Press Enter. The panel displays Sn ## Grp ## .
8. Press the scroll buttons until the panel displays the sensor you want to delete.
9. Press Enter. The panel displays Deleted, then shows Delete sensor.
10. Press STATUS twice to exit.
Editing sensors
You can use this feature to change the group or name of a sensor that is already in panel memory. The
procedure is very similar to the procedure used to program sensor information after a sensor is learned in.
Pressing DISARM while editing sensor text deletes all text for that sensor.
Table 17. Sensors
Function
Default
Description
Learn sensors
Adds (learns) sensors to panel memory.
Delete sensors
Deletes sensors from panel memory.
Edit sensors
Edits sensor information in panel memory.
Chapter 4
Programming
Reporting
Table 18 and Table 19 on page 49 provide report option details.
Table 18. Reporting options
Function
Default
Description
Opening reports
Off
Determines whether the panel sends opening reports to a central station whenever the
system is disarmed (on), or not (off). User number will be reported as zone number.
Keyfobs learned into zone 1 to 40 will report as zone they are learned into.
Dealer code = 44
Installer code = 45
Master code = 46
User code 1 = 47
User code 2 = 48
User code 3 = 49
User code 4 = 50
User code 5 = 51
User code 6 = 52
User code 7 = 53
User code 8 = 54
Duress code = 55
Closing reports
Off
Determines whether the panel sends closing reports to a central station whenever the
system is armed (on), or not (off). User number will be reported as zone number. Keyfobs
learned into zones 1 through 40 will report as the zone they are learned into.
Dealer code = 44
Installer code = 45
Master code = 46
User code 1 = 47
User code 2 = 48
User code 3 = 49
User code 4 = 50
User code 5 = 51
User code 6 = 52
User code 7 = 53
User code 8 = 54
Duress code = 55
Force armed
Off
Determines whether the panel sends a force armed report to a central station if the user
bypasses protesting sensors (indirect bypass) when arming the system (on) or not (off).
AC power failure
Off
Determines whether or not the panel sends AC power failure reports to a central station
after the programmed time expires. The time can be set from 005-254 minutes.
• When the panel is without AC power for 30 seconds, the panel LEDs turn off.
• When the panel is without AC power for the programmed time, an AC power failure
is reported.
• The panel reports an AC power restoral when AC power returns to the panel.
47
48
Simon XT
Installation Manual
Table 18. Reporting options (continued)
Function
Default
Description
Low CPU battery On
Determines whether the panel sends a low CPU battery report to the central station
when the panel backup battery voltage drops
Sen alarm
restore
Determines whether the panel reports sensor alarm restorals (on) or not (off). Setting
when restorals are reported:
Off
1.
Immediately after sensor is closed or restored after dial delay.
2.
After siren timeout expires if sensor is restored.
3.
When system is disarmed if sensor is restored.
24-hour sensor
tamper
Off
Determines whether the system (armed or disarmed) goes into and reports an alarm
anytime a sensor tamper switch is tripped (on), or only when the system is armed and a
tamper switch of an armed sensor is tripped (off).
Supervisory
tamper a
Off
Determines whether the panel sends supervisory reports to a central station as a
tamper (on) or a supervisory (off).
This option is typically used only in Europe where a supervisory condition is required to
report as a tamper.
No usage a
Off
Determines whether the panel sends a No Usage report to the central station if the user
has not operated the system before the programmed time expires (on) or not (off). The
timer starts each time the system is disarmed.
This is a customer service feature that alerts the central station if a customer is not
using their security system. The service provider can then contact the customer to find
out why the system is not being used, and help correct any problems for the customer.
Swinger
shutdown
On
Determines whether the panel prevents the same sensor from activating an alarm more
than once in a single arming period (on) or not (off).
Note: Swinger Shutdown does not affect smoke and fire sensors.
Program report
Off
Determines whether the panel sends a report to the central station anytime the
programming mode is entered/exited (on) or not at all (off). The panel sends a report
whenever the dealer (Utility 1) or installer (Utility 2) code is used to enter programming
mode and another report is sent when the programming session ends.
Fire verify
Off
If this option is off, the panel immediately reports to the central station when a smoke
detector goes into alarm.
With this option on, if a single smode detector goes into alarm the panel will not report
for 60 seconds unless another smoke detector goes into alarm. If the first smoke
detector is cleared of alarm with the first 60 seconds, no report will be sent to the
central station unless it or a second smoke detector goes into alarm within the panel
siren timeout period (5 minutes).
a.
Not investigated for use by UL.
Chapter 4
Programming
Table 19. Communication modes
Function
Default
Description
Phone 1 report
mode
Off
All SIA
All CID
Phone 2 report
mode
Alarm SIA
Phone 3 report
mode
Nonalarm SIA
Alarm CID
Nonalarm CID
Backup SIA (phone failure backup)
Phone 4 report
mode
Backup CID (phone failure backup)
Voice dialer
Off
Note: UL has only verified reporting compatibility with the CS5000 Digital Alarm Communicator Receiver. For UL listed systems,
Phone 1 Report Mode must be set to All SIA or All CID.
Alarms include: Fire, Intrusion, Emergency, Silent, and Alarm Cancels.
Nonalarms include: Latchkey, No Activity, Openings, Closings, Fail to Open, Fail to Close, Force Armed, AC
Power Failure, CPU Low Battery, and Trouble Restorals.
Timers
Table 20 provides timer option details.
Table 20. Timers
Function
Default
Description
Latchkey time a
Off
Determines whether the panel reports a latchkey alarm if the system is not disarmed at
a preset time between midnight and 11:59 P.M. (on). If the latchkey feature is disabled
(off), the panel will not report a latchkey alarm.
The system clock must be set for the latchkey feature to work.
Entry delay
030 seconds
Determines how much time the user has to disarm the system after entering the armed
premises through a designated delay door, before an alarm occurs. Beeps sound during
the entire delay time to remind the user to disarm the system.
When turned on, the Entry Delay can be set from 030 to 240 seconds.
Exit delay
060 seconds
Determines how much time the user has to leave the premises through a designated
delay door after arming the system. Beeps sound after arming the system to remind the
user to leave the armed premises. If a delay door is opened after the Exit Delay expires,
the Entry Delay begins. If the user arms the system with No Delay and opens a delay
door after the Exit Delay expires, an alarm occurs.
When turned on, the combined dial and entry delay cannot exceed 60 seconds for a UL
Listed installation.
49
50
Simon XT
Installation Manual
Table 20. Timers (continued)
Function
Default
Description
No activity tm a
Off
Determines whether the panel sends a No Activity report to a central station when the
programmed time period elapses (on), or if the feature is disabled (off).
No activity means control panel, remote handheld, and key-chain touchpad buttons
have not been pressed and sensors have not been tripped within a specified period of
time (except sensors in group 25).
The timeout can be set from 02 to 24 hours.
Autophone test b Off
Determines whether the panel automatically performs a periodic phone test (on) or not
(off). The test interval can be from 001 to 254 days. The time of day the panel performs
the test is determined by Supervisory Time, which must be turned on for this feature to
work.
Supervisory
time
Determines when the panel reports supervisory conditions (sensor failures) and
automatic phone tests to the central station.
12:00am
The panel clock must be set to the correct time for this option and the automatic phone
test to work correctly.
Alarm cancel
006
Sets the time frame that determines whether the panel reports an alarm cancel
message to the central station. If the system is disarmed from an alarm state within the
programmed time, the panel sends an alarm cancel message to the central station. An
alarm cancel message is not reported if the system is disarmed after the programmed
time expires.
The time can be set from 006 to 255 minutes. When set to 255, the panel always reports
alarm cancel messages. Turning off this option disables alarm cancel reporting.
RF time-out
12 hours
Determines the time period the panel must receive at least one supervisory signal from
learned sensors before identifying a sensor failure and sounding trouble beeps. Any
sensor failure is reported immediately and again at the supervisory time (Supervisory
Time). The timeout can be set from 02-36 hours. Entries must be two digits.
Fail-to-open
time a
Off
Determines whether the panel sends a Fail to open report to a central station if the
system has not been disarmed by the programmed time (on), or not (off).
System time must be set correctly for this feature to work.
Fail-to-close
time a
Off
Determines whether the panel sends a Fail to Close report to a central station if the
system has not been armed by the programmed time (on), or not (off).
System time must be set correctly for this feature to work.
Siren time-out
005 minutes
Determines how long sirens sound alarms if no one is present to disarm the system. The
time can be set from 002 to 254 minutes. When this feature is turned off, sirens sound
alarms until the alarm is canceled (system is disarmed).
Arm LED
shutdown
Off
Determines whether the panel LEDs (buttons) turn off 30 seconds after the last button
press (on) or remain on for the entire arming period (off).
Unvacated
premises
On
Determines whether the system automatically arms down to level 2 (doors and
windows) if the user arms the system to level 4 (doors, windows, and motion sensors)
without leaving the premises (on), or remains at the armed level chosen by the user (off).
This feature does not work from a keyfob. Autobypass must be on for this feature to
work.
Chapter 4
Programming
Table 20. Timers (continued)
Function
Default
Description
Smoke
supervision
Off
Determines how often the panel must receive supervisory signals from the smoke
sensors. If this option is on, the panel must receive at least one supervisory signal from
smoke sensors every four hours or it will identify a sensor failure and sound trouble
beeps. If this option is off, the time for receiving supervisory signals is determined by RF
Timeout.
a.
b.
Not investigated for use by UL.
For UL installations, auto phone test must be turned on and set to 24 hours (1 day).
Touchpad options
Table 21 provides touchpad option details.
Note: These options have not been investigated by UL..
Table 21. Touchpad options
Function
Default
Description
Keyfob no delay
Off
Determines whether a keyfob arms the system with no delay (on) or not (off).
When this feature is on, you must disarm the system before entering the premises, since
it is disabling the entry delay. If Remote touchpad arming is on, keyfobs cannot disarm
the system and will cause an alarm upon entering.
Panic alarms
On
Determines whether the panel panic buttons (police, auxiliary, and fire) activate alarms
when pressed (on) or not (off)
Remote TP arm
Off
Determines whether keyfobs and remote touchpads can disarm the system only during
exit and entry delays (on) or arm and disarm the system anytime (off). If this option and
Keyfob no delay are on, users cannot enter and/or disarm using remote touchpads
without causing an alarm.
System options
Table 22 provides system option details.
Table 22. System options
Function
Default
Description
RF jam detect
Off
Determines whether the panel checks for and reports RF interference/jam to the central
station (on) or not (off). If this option is on and the panel receives a constant 319.5 MHz
signal, the panel reports the condition to the central station. If this option is off, the
panel does not detect an RF jam.
Demo mode a
Off
Determines whether the panel operates as a demonstration model (on) or a standard
panel (off).
Turning on this feature disables low battery supervision and allows the microphone to
remain on continuously during an AVM session. With option on panel is not testing
battery supervision.
51
52
Simon XT
Installation Manual
Table 22. System options (continued)
Function
Default
Description
HW 1 function
The setting for this option determines how the HW1 I/O output will function.
24-hour clock
a.
Off
Off =
No output.
1=
Interior siren output.
2=
Output activated when armed.
3=
Output activated when disarmed.
4=
Fail to communicate output; activates when fail to communicate condition
occurs (Fail to communicate must be on) two.
5=
Alarm output activated when panel is in alarm
Determines whether the panel uses a 24-hour clock (on) or 12-hour clock (off).
Not investigated for use by UL.
Siren options
Table 23 provides siren option details.
Table 23. Siren options
Function
Default
Description
Piezo beeps
On
This option determines whether the panel piezo produces beeps based on system
activity (on) or is silent (off).
Panel voice
On
When On, arming level changes will be spoken.
Panel piezo
alarm
On
Determines whether the panel piezo emits alarm sounds (on) or not (off).
Trouble beeps
On
Determines whether the panel, X10, and hardwired interior sirens sound six beeps every
minute when a trouble condition occurs (on) or not (off). The following conditions cause
trouble beeps:
AC power failure (when AC power failure report is on) low CPU battery
Sensor failure (supervisory)
Sensor trouble (low battery, tamper, etc.)
Fail to communicate
Restoration of power
No Activity timer has timed out. Trouble beeps continue for 5 minutes and if the panel
does not see activity, trouble beeps stop and the panel reports the no activity to the
central station.
Trouble beeps can be silenced by arming or disarming the system or by pressing the
STATUS button. Trouble beeps resume 4 hours later if the trouble condition is not
cleared.
Voice chime
Off
Determines whether the panel announces the sensor name.
1 = Sensor name
2 = Loud ding-dong bell
3 = Soft ding-dong bell
Off = No sound
Chapter 4
Programming
Table 23. Siren options (continued)
Function
Default
Description
Status beeps vol. 7
Determines the panel piezo volume level for status sounds such as arming, trouble, and
status beeps. Volume range is 1 (lowest) to 10 (highest).
HW siren sup.
Off
Determines whether the panel monitors hardwired sirens for open conditions (on) or not
(off). If this option is turned on, sirens connected to the panel terminals require an EOL
resistor in the wire circuit. (See on page 17 for siren wiring.) If this option is turned off,
EOL resistors are not required whether sirens are connected or not.
Speaker volume
Sets the volume of voice messages from the panel speaker. Volume range is 1 (lowest)
to 8 (highest).
Silent police
panic
Off
Determines whether pressing the panel police panic button causes an audible (off) or
silent (on) alarm.
Panel tamper
alarm
Off
Determines whether the panel activates a tamper alarm anytime the cover is opened
(On) or only when the system is armed (Off).
Alarm report
verify
Off
This option determines whether the panel verifies successful alarm reports to the
central station by displaying Phone comm is OK (On), or not (Off).
Piezo beep options
Table 24 provides piezo beep option details
Table 24. Panel piezo beeps
Activity
Piezo beep response
Arm doors and
windows
Exit delay—two beeps sound every five seconds and two times per second during the last ten seconds.
Silent exit—two beeps sound at the beginning of the exit delay and two more sound just before the exit
delay expires.
Entry delay—two beeps sound every five seconds and two times per second during the last ten seconds.
Arm motion
sensors
Exit delay— three beeps sound every five seconds and three times per second during the last ten seconds.
Silent exit— three beeps sound at the beginning of the exit delay and three more sound just before the exit
delay expires.
Entry delay— three beeps sound every five seconds and three times per second during the last ten
seconds.
Arm doors/
windows and
motion sensors
Exit delay— four beeps sound every five seconds and four times per second during the last ten seconds.
Silent exit— four beeps sound at the beginning of the exit delay and four more sound just before the exit
delay expires.
Entry delay— four beeps sound every five seconds and four times per second during the last ten seconds.
Disarm
One beep
Chime
Two beeps (when programmed)
Special chime
Three beeps (when programmed)
Trouble beeps
Six beeps every minute. Press STATUS to stop beeps for four hours.
No activity a
Twenty beeps every minute for five minutes (when programmed)
a.
Not investigated for use by UL.
53
54
Simon XT
Installation Manual
Audio verification options
Table 25 provides audio verification option details.
Note: These options have not been investigated for use by UL.
Table 25. Audio verification
Function
Default
Description
Audio mode
Off
1 = Instant. Panel stays online with central station for an instant audio session.
2 = Callback. Panel hangs up and waits for a callback from the central station operator
before starting an audio session.
Off = No audio verification.
Fire shutdown
Off
Determines whether system Fire sirens are silenced during a two-way audio session (on)
or not (off). Beeps sound every 10 seconds while sirens are silenced.
Panic talk
Off
Determines whether the central station operator can talk to the user during a silent
alarm (off) or just listen in on the premises (on). Silent alarms occur when sensors
learned into groups 02 or 03 are tripped, when the duress code is entered, or when the
panel Police button is pressed and the Silent Panel Police Panic option is turned on.
Vox Rx gain
06
Determines the receiver gain level during two-way audio sessions. If the VOX is
switching the speaker on when the central station operator is not talking, lower both
this setting and the VOX mic gain setting. If the VOX is not switching the speaker on
when the central station operator is talking, raise this setting and lower VOX Mic Gain
setting. Changing this setting does not affect speaker volume.
Vox mic gain
24
Sets the mic gain (sensitivity) that triggers the voice-activated switching (VOX). Room
size, acoustics, and furnishings where the panel or Interrogator 200 are located will
influence the setting. Gain range is 01 (lowest) to 64 (highest).
Vox mic gain rng 64
Sets the gain range for voice-activated switching (Vox). Range is 01 (lowest) to 64
(highest). For best results, this option should be set equal to or greater than Vox mic
gain.
Note: This option works in conjunction with Vox mic gain. It is important to follow the
setting recommendations as described to achieve acceptable operation.
Manual mic gain 64
Determines the gain level (sensitivity) during two-way audio sessions when audio mode
is set to 0 or 1 (speak). Room size, acoustics, and furnishings where the panel is located
will influence the setting. Gain range is 01 (lowest) to 64 (highest).
Light control (optional)
If your system uses optional X10 modules, you can program them to control lights.
Note: This feature has not been investigated for use by UL.
X10 module operation
Use the following procedure to program X10 module operations into panel memory.
To program the housecode:
1. Press the scroll buttons until the panel displays System programming.
Chapter 4
Programming
2. Press Enter. The panel displays Enter code.
3. Enter your access code and press Enter. The panel displays Access codes.
4. Press the scroll buttons until the panel displays Light control.
5. Press Enter. The panel displays Set entry lights.
6. Press the scroll buttons until the panel displays Housecode .
7. Press Enter. The letter flashes.
8. Press the scroll buttons until the letter you want displays.
9. Press Enter to accept the new housecode. The panel displays Housecode .
10. Press STATUS twice to exit program mode.
To program an entry-activated light:
1. Press the scroll buttons until the panel displays System programming.
2. Press Enter. The panel displays Enter code.
3. Enter your access code and press Enter. The panel displays Access codes.
4. Press the scroll buttons until the panel displays Light control.
5. Press Enter. The panel displays Set entry lights.
6. Press Enter. The panel displays Entry light unit 1 on/off.
7. Press the scroll buttons until the unit number you want to program displays.
8. Press Enter. The panel displays Off, which will be flashing.
9. Press the scroll buttons until the panel displays On, then press Enter.
10. Press STATUS three times to exit program mode.
To program a sensor-activated light:
1. Press the scroll buttons until the panel displays System programming.
2. Press Enter. The panel displays Enter code.
3. Enter your access code and press Enter. The panel displays Access codes.
4. Press the scroll buttons until the panel displays Light control.
5. Press Enter. The panel displays Set entry lights.
6. Press the scroll buttons until the panel displays Sensor light.
7. Press Enter. The panel displays Sn ##  X-10 unit = on/off.
8. Press the scroll buttons until the panel displays the sensor number you want to activate.
9. Press Enter. The panel displays On/off, which will be flashing.
10. Press the scroll buttons until the panel displays On.
11. Press Enter.
12. Press STATUS three times to exit.
55
56
Simon XT
Installation Manual
Note: You can also program a keyfob button to control a light or appliance module.
To program a light schedule:
1. Press the scroll buttons until the panel displays System programming.
2. Press Enter. The panel displays Enter code.
3. Enter your access code and press Enter. The panel displays Access codes.
4. Press the scroll buttons until the panel displays Light control.
5. Press Enter. The panel displays Set entry lights.
6. Press the scroll buttons until the panel displays Set entry lights.
7. Press Enter.
8. Press the scroll buttons until the panel displays Light schedules.
9. Press Enter. The panel displays Light schedule 1 <--:-- - --:-->.
10. Press the scroll buttons until the panel displays the unit number you want to program.
11. Press Enter. The HH of the start time will flash.
12. Press the scroll buttons to set the hours.
13. Press Enter. The MM of the start time will flash.
14. Press the scroll buttons to set the minutes.
15. Press Enter. The AM/PM of the start time will flash.
16. Press the scroll buttons to set the AM/PM setting.
17. Press Enter. The end time starts to flash.
18. Follow the same instructions to set the hour, minute, and AM/PM settings for the end time.
19. Press STATUS repeatedly to exit.
Lock interval
Note: This feature has not been investigated for use by UL.
Sets the start and stop times that determine when the panel prevents the sensor-activated lights feature from
turning on sensor-activated lights.
Note: System time must be set correctly for this feature to work.
When a time value is set (on) and the sensor-activated lights feature is on, the panel prevents sensor-activated
lights from turning on between the programmed start time (this option) and the programmed stop time.
Note: Both sensor-activated light lockout start time and sensor-activated light lockout stop time must have a time programmed
for this feature to work correctly.
Chapter 4
Programming
When both sensor-activated light lockout start time and sensor-activated light lockout stop time are turned off
and the sensor-activated lights feature is on, sensor-activated lights turn on at all times.
Table 26. Light control
Function
Set entry lights:
Entry light unit,
1 through 8
Default
Description
Off
This menu allows the user to set X-10 lights with unit numbers from 1
to 8 as entry lights (On).
Sensor light # 01 to 40
Light schedules
Light schedule,
1 through 8
Housecode
Lock interval
In this menu, each enrolled sensor can be associated with an X-10
light with unit number from 1 to 8 (or Off for no association).
Off
In this menu, a light schedule can be programmed for each X-10
module with unit number from 1 to 8.
(Light) lock
interval
Blank
This option sets the daily lockout time during which sensor trips do
not activate associated X-10 lights
Default
Description
System tests
Table 27. System tests
Function
System tests
a.
Comm test
The communication test is used to check the phone communication
between the panel and the central station or voice report
destination.
Sensor test
The sensor test is used to check proper sensor operation.
System
download a
This feature initiates a phone call from the panel to the Enterprise
Downloader.
Not investigated for use by UL.
57
58
Simon XT
Installation Manual
Resetting memory to the factory defaults
To reset the panel to its factory defaults, do the following:
1. Open the panel cover.
2. Unplug the transformer and disconnect the battery.
3. Press and hold the four arming/status buttons (DOORS+WINDOWS, MOTIONS, DISARM, and
STATUS) on the front of the panel and the tamper switch on the inside of the panel (see Figure 5 on
page 24).
4. Restore power to the panel with the battery while holding the four buttons and tamper switch.
5. Release the buttons.
6. Plug in the transformer to the outlet.
Note: The procedure to reset memory to factory defaults is meant to be difficult. It is also possible to restore power to the panel
by plugging in the transformer first, which allows the panel to be closed so that the tamper switch does not need to be
pressed. If you do this, be sure to reconnect the battery.
Program the panel in this order:
1. Set the panel clock.
2. Add (learn) sensors.
3. Set the housecode and light and appliance controls (entry/exit activated lights, sensor-activated lights,
time-activated lights).
4. Change options as needed.
Note: If phone lock is on, phone numbers 1 and 2, downloader phone number, account number, phone lock, downloader code,
phone report mode 1, phone report modes 1 to 4, access code length, and call waiting and dealer code will not reset to their
defaults.
Chapter 5 Testing
This section describes how to perform various test procedures. You should test
the system after installing, after servicing, and after adding or removing devices
from the system.
In this chapter:
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Sensor testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
If a sensor fails the sensor test . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Phone communication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Offsite phone operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Central station communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Two-way voice operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Voice event notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
X10 operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Manual lamp module control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
X10 siren and lamp module functions. . . . . . . . . . . . . . . . . . . . . . . .66
60
Simon XT
Installation Manual
Control panel
Test the panel by pressing the buttons as described in Table 28. Table 29 provides a list of the arming levels.
Note: An access code is required when arming if the Secure arming option is on..
Table 28. Control panel test sequence
Button
Function tested
Test
Correct result
DOORS +
WINDOWS
The panel arms door and
window sensors.
Press DOORS + WINDOWS a second
time to eliminate the programmed
entry delay.
The button will blink when No entry
delay is on.
MOTIONS
The panel will arm motion
sensors.
Press MOTIONS a second time to
turn latchkey on.
The button blinks when latchkey is
on.
DISARM
The panel will prompt you to
enter an access code.
Enter the appropriate code.
The panel will disarm doors,
windows, and motion sensors.
STATUS
Press STATUS button for panel to
display and speak the system status.
POLICE
Press and hold or press button twice
quickly to activate a nonmedical,
police, or fire emergency alarm.
FIRE
Press and hold or press button twice
quickly to activate a nonmedical,
police, or fire emergency alarm.
EMERGENCY
Press and hold or press button twice
quickly to activate a nonmedical,
police, or fire emergency alarm.
Note: Forty key presses for invalid codes (ten invalid 4-digit codes, for example) will cause a system access alarm. The alarm
locks all touchpads, except keyfobs, for 90 seconds.
Table 29. Arming levels
Arming level
Description
Indication
Subdisarms (master access
and duress codes only), and
bypasses 24-hour intrusion
sensors (master access
code only). Fire sensors
(group 26) cannot be
subdisarmed.
One beep indicates the system is subdisarmed. The panel displays and
speaks Subdisarmed. The DISARM button blinks.
Disarm the system
One beep indicates the system is disarmed. The panel displays and speaks
Disarmed. The DISARM button lights.
Arm doors and windows
Two beeps verify that door/window sensors are armed. The panel displays
Doors + Windows and speaks Doors and windows on. The
DOORS+WINDOWS button lights.
Arm motion sensors
Three beeps verify that motion sensors are armed. The panel displays
Motions and speaks Motions On. The MOTIONS button lights.
Arm doors, windows, and
motion sensors
Four beeps verify that door/window and motion sensors are armed. The
panel displays Doors + Windows & Motions and speaks Doors and
windows on, Motions on. The DOORS+WINDOWS and MOTIONS buttons
light.
Chapter 5
Testing
Sensor testing
Test the sensors after all programming is completed and whenever a sensor-related problem occurs.
Note: While the sensor test is a valuable installation and service tool, it only tests sensor operation for the current conditions.
You should perform a sensor test after any change in environment, equipment, or programming.
Notify the central station you will be performing a test prior to starting the test. To test the sensors, do the
following:
1. Place all sensors in their secured (no alarm) state.
2. Go to the Sensor Test option under the System tests menu, then press Enter.
The panel will prompt you to trip each sensor one at a time. You may follow the panel prompting or test the
sensors in any order. Use Table 30 to trip sensors.
Table 30. Sensor tripping instructions
Sensor
Do this
Door/window
Open the secured door or window.
Freeze
Remove the sensor cover. Apply ice in a plastic bag to the sensor (for 10 to
15 minutes). Do not allow the sensor to get wet.
Water
Press a wet rag or wet finger over both of the round, gold-plated terminals
on the underside of the sensor.
Carbon monoxide alarm
Unplug the CO Alarm. Plug it back in, wait 5 seconds, then press the TEST/
RESET button until the unit beeps 8 times.
Glassbreak
Tap the glass 3 to 4 in. (8 to 10 cm) from the sensor.
Motion sensor
Avoid the motion sensor field of view for five minutes, then enter its view.
Rate-of-rise heat detector
Rub your hands together until warm, then place one hand on the detector
for 30 seconds.
Shock
Tap the glass twice, away from the sensor. Wait at least 30 seconds before
testing again.
Smoke
Press and hold the test button until the system sounds transmission beeps.
Personal help button
Press and hold the appropriate help button until the light blinks and the
panel sounds for at least seven beeps.
Keyfob
Press and hold LOCK and UNLOCK simultaneously for three seconds.
Remote handheld touchpad
Press and hold the two EMERGENCY buttons simultaneously for three
seconds.
3. Interior sirens sound transmission beeps, and the display identifies the tripped sensor and the number
of RF packets received. Each beep represents one RF packet. Count the number of beeps and refer to
Table 31 for minimum requirements. After the beeps, the panel displays Sn # Packets=XX Name
(where XX equals the number of RF packets and Name equals the sensor name). The system will
continue to prompt for sensors that have not yet been tested. When all sensors have been tested, the
panel will display Sn test complete Press Status.
Note: If a sensor does not meet the minimum transmission beep requirements, see If a sensor fails the sensor test on page 62.
61
62
Simon XT
Installation Manual
Table 31. Minimum beeps
Type of sensor
Number of beeps
Wireless intrusion sensors
7–8
Wireless smoke and heat sensors
7–8
Wireless environmental/panic buttons
7–8
Hardwired loops
Emergency buttons (remote handheld touchpads only)
7-8
4. Press STATUS. The panel displays Sensor Test Ok.
5. If you press STATUS and the panel has not heard from all sensors, the panel will display Sn test fail or
aborted.
If a sensor fails the sensor test
If sirens do not beep when a sensor is tripped, use an RF Sniffer (60-401) test tool to verify that the sensor is
transmitting. Constant beeps from the RF Sniffer indicate a runaway (faulty) sensor. Replace the sensor.
If possible, locate sensors within 100 feet (30 meters) of the panel. While a sensor may have a range of 500 feet
(152 meters) or more out in the open, the environment at the installation site can have a significant effect on
transmitter range. A change in sensor location may help overcome adverse wireless conditions and can be
accomplished by the following:
•
•
•
Reposition the sensor
Relocate the sensor
If necessary, replace the sensor
To reposition a sensor:
1. Rotate the sensor and test for improved sensor communication at 90 and 180 degrees from the original
position.
2. If poor communication persists, relocate the sensor.
To relocate a sensor:
1. Test the sensor a few inches from the original position.
2. Increase the distance from the original position and retest until an acceptable location is found.
3. Mount the sensor in the new location.
4. If no location is acceptable, replace the sensor.
To replace a sensor:
1. Test a known good sensor at the same location.
2. If the transmission beeps remain below the minimum level, avoid mounting a sensor at that location.
3. If the known-good sensor functions, contact GE Security for repair or replacement of the problem
sensor.
Chapter 5
Testing
Phone communication
Perform a communication test to check the phone communication between the panel and the central station.
To perform a communication test:
1. Go to the Comm test option under the System tests menu.
2. Press Enter. The panel confirms that a communication test has begun. When the communication test is
complete, the panel will display Comm test is OK within 3 minutes.
If the test is unsuccessful, the STATUS button will light and the panel will display Comm failure within 10
minutes.
If the panel displays Comm failure:
1. Check that the panel is connected to the phone jack.
2. Check the phone number programmed into the panel.
3. Perform the communication test again.
4. If the communication test fails again, check the phone connection wiring.
Offsite phone operation
Test the system from a remote phone by calling the panel and using the commands in Table 32.
Note: This feature has not been investigated by UL.
Table 32. Phone commands
System function
Phone command
Disarm
Arm doors/windows
Arm motion sensors
Arm doors/windows with no entry delay
2–2
Arm motion sensors with latchkey
3–3
Arm doors/windows and motion sensors
2–3
Arm doors/windows with no entry delay and motion sensors
with latchkey
2–2–3–3
Specific light on
* – .
Specific light off
# – .
All lights on
*–*
All lights off
#–#
System status
Audio verification
5 + X (X = a command from Audio Verification Set)
Terminate session
63
64
Simon XT
Installation Manual
Central station communication
After performing sensor and communication tests, check that the system is reporting alarms successfully to the
central station. Table 33 provides a list of sensor/user report codes.
To test communication with the central station:
1. Call the central station and tell the operator that you will be testing the system.
2. Arm the system.
3. Test each of the wireless panic buttons and trip at least one sensor of each type (fire, intrusion, etc.) to
verify that the appropriate alarms are working correctly.
4. When you finish testing the system, call the central station to verify that the alarms were received.
Table 33. Sensor/user report codes
Arm or disarm from
Reports as user
Panel or remote handheld touchpad
Keyfob
1 to 40 (sensor number)
Panel aux panic
41
Panel tamper
42
Panel police panic
43
Panel fire panic
44
Dealer access code
44
Installer access code
45
Master code
46
Access codes 1 to 8
47 to 54
Duress code
55
Chapter 5
Testing
Two-way voice operation
For the central station operator to initiate an audio session:
Note: Panel voice announcements are silenced during AVM sessions. If the operator does not terminate the session correctly,
panel announcements may not occur for up to 90 seconds after the operator hangs up.
1. After the panel has completed reporting the alarm, pick up the CS phone and press the * button to start
the audio session.
2. Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 to listen.
3. Press 99 to terminate the session.
Table 34. Audio verification set
Phone buttons
Function
0-1
Speak
VOX operation
3 or 6
Listen
Extend session for 90 more seconds
88
Terminates session with call back (the panel answers on the first ring if called within 5 minutes)
99
Terminates session with no call back
Voice event notification
Testing this feature requires two people; one at the alarm site and the other at the location the panel is
programmed to call.
1. Contact the central monitoring station (if system is monitored) to inform them you are testing the
system and not to dispatch authorities.
2. At the system site, put the system into an alarm condition.
3. At the calling location, pick up the phone after it starts ringing. You should hear the panel voice
announce Press star for alarm.
4. Press * and the panel voice identifies the alarm. If there is more than one alarm in progress, the user
must press * for the panel voice to identify them.
Note: You must terminate the call by pressing #. Otherwise, the panel may not disconnect from the phone line for up to 2
minutes.
5. After all alarms have been identified, the panel announces Press # to exit.
6. Press # to terminate the call.
65
66
Simon XT
Installation Manual
X10 operation
The following sections describe how to test X10 lamp, siren, appliance, and universal module operation.
Manual lamp module control
•
•
•
Control panel: Press the asterisk button (*) and the unit number of the lamp module using the numeric
buttons to test individual lamp modules 1 through 8. The panel responds with Light # on/off. Press the
asterisk button (*) twice to turn on all lamp modules. Press the pound button (#) twice to turn off all
lamp modules.
Keyfob: Press the Light button repeatedly to turn all lights on and off. The panel responds with Lights
on/off.
Remote handheld touchpad: Press the Lights on button and the unit number of the lamp module
using the numeric buttons to test individual lamp modules 1 through 8. The panel responds with Light
# on/off. Pressing the Lights on or Lights off button twice turns all the lights on or off.
X10 siren and lamp module functions
All sirens turn off when the system is disarmed or when the siren timeout expires. Siren priority is fire (highest
priority), intrusion, and emergency. Table 35 identifies the light information for each of these siren types.
Table 35. Alarm siren and X10 light information
Fire
Intrusion
Emergency
X10 lights
Steady
Flashing
Steady
X10 siren
Steady
Steady
Alarm beeps
Interior and panel Siren
Temporal 3
Steady
Fast on/off
If an alarm of greater priority occurs during an alarm of lower priority, the greater priority alarm sirens sound.
Fire alarms sound a temporal 3 pattern (0.5 seconds on, 0.5 seconds off for three beeps then 1.5 seconds off).
Note: The X10 siren must be set to unit #9 to “hear” emergency alarms and status beeps. To hear emergency alarms only, set to
unit #10.
Chapter 6 Troubleshooting and support
This chapter provides information to help you troubleshoot problems, perform
simple preventive maintenance procedures, and contact technical support in case
you need assistance with your GE equipment.
In this chapter:
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Contacting us. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Online resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
68
Simon XT
Installation Manual
Troubleshooting
This section provides information to help you diagnose and solve various problems that may arise while
configuring or using your GE product and offers technical support contacts in case you need assistance. (See
Contacting us on page 70.)
System status
To clear STATUS (alarm memory), do the following:
From a disarmed state press STATUS, listen to the status message, then press DISARM.
The panel displays and announces Siren 1 failure.
•
•
Turn the Hardwired Siren Supervision option off if a hardwired siren or sensor is not connected.
Check for the correct end-of-line resistor in HW1 I/O circuit.
Panel displays and announces Low battery.
•
•
•
Check that panel backup battery is connected.
Check panel backup battery voltage. If less than 5.4 volts, replace battery and clear system status
message.
Run sensor test.
The panel displays and announces RF jam.
•
The control panel has detected RF interference.
The panel displays and announces that a sensor is open.
•
See Sensors on page 69.
The panel displays Set Time and announces System time is not set.
•
Set the system time.
Control panel
The panel displays and announces Invalid.
•
This sensor is already programmed. Delete sensor if not correctly programmed.
Options (programmable by the homeowner)
The panel does not beep.
•
Turn on Piezo Beeps option.
Latchkey does not function.
•
•
•
•
Latchkey time is not set. Set latchkey time.
Latchkey is not enabled. Enable latchkey by pressing MOTIONS twice.
The phone number is not programmed properly. Reprogram the phone number.
System time is not set. Set system time.
Chapter 6
Troubleshooting and support
Sensors
A sensor does not work.
•
•
•
Make sure the battery is good and installed correctly.
Check for interference from metal objects. Move or rotate the sensor.
Move the sensor to a new location.
Door or window is closed, but the panel announces it is open.
•
•
Be certain the arrow on the magnet and the guide line on the transmitter are aligned and within 1/4 inch
of each other.
The sensor tamper switch may be open (cover off).
Motion sensors go off continuously.
•
Be sure the sensor is mounted on a solid surface and the viewing field is free from sources of changing
temperature.
Motion sensor does not respond to motion.
•
•
•
•
•
Make sure the sensor battery is good and installed correctly. Wait 2 minutes after installing a new
battery to test the sensor.
Adjust the sensor mounting.
Leave the area for 3 minutes, then retest.
The environment is too hot or too cold. Outdoor sensors operate between 32 and 120°F (0 and 49°C).
Dirt or dust may be causing the problem. Wipe the sensor with a clean, damp cloth.
X10 modules
All lamp modules or siren not working.
•
•
•
Be sure the panel transformer is plugged into an outlet that is not controlled by a switch.
Check that the panel is powered using the line carrier power transformer.
Housecode was programmed incorrectly.
One lamp module or siren is not working.
•
•
•
•
•
•
Unplug nearby equipment that may be causing interference (light dimmer switches, televisions,
appliances with older motors).
Check that the switch on the lamp or appliance is turned on and remains on.
Make sure the lamp has a working bulb.
Make sure the lamp or appliance is plugged into the Lamp/Appliance Module, the Module is plugged
into the outlet and the outlet is not controlled by a switch.
Make sure the House and Unit Codes are correct.
Move the Module to a different outlet that is on the same phase (branch) of the household electrical
circuit as the panel.
Time- or sensor-activated light not working.
•
•
•
Make sure you have programmed the light to be activated by a timer or sensor.
Make sure the system clock is set.
Make sure these functions have been enabled. The functions are enabled if the appropriate icon is
shown on the display.
69
70
Simon XT
Installation Manual
Contacting us
For help installing, operating, maintaining, and troubleshooting this product, refer to this document and any
other documentation provided. If you still have questions, contact us during business hours (Monday through
Friday, excluding holidays, between 5 a.m. and 5 p.m. Pacific Time).
Table 36. Technical support
North America
Latin America
T: 888 GE Security (888.437.3287). Toll-free in the US,
Puerto Rico, and Canada.
503.885.5700 outside the toll-free area.
T: 305.593.4301
F: 888.329.0332 (Tualatin tech support)
561.998.6232 (Boca Raton tech support)
E: nstechsrv@ge.com (tech support)
gesecurity.customerservice@ge.com (customer service)
F: 305.593.4300
E: InfraSec.TechnicalServicesLatinAmerica@ge.com (técnica)
InfraSecCustomerService.LatinAmerica@ge.com (cliente)
Europe, Middle East, and Africa
W: At www.gesecurity.eu, select Customer Support.
Note: Be ready at the equipment before calling.
Online resources
Here are some useful links on our website www.gesecurity.com:
Online library. From the Customer Support menu, select the Resource Library link. After you register
and log on, you may search through our online library for the documentation you need.1
Training. To view any available online training for GE Security products, select the Training link.
(Online training is not available for all products.)
Warranty and terms information. From the Customer Support menu, select Return and Warranty
Policy Statement or Terms and Conditions Policy Statement.
Customer service and technical support. From the Customer Support menu, select Customer Service or
Technical & Application. Select the appropriate product category for the contact information or use the
dropdown menu to select a location outside the US.
1.
Many GE documents are provided as PDFs (portable document format). To read these documents, you will need Adobe
Reader, which can be downloaded free from Adobe’s website at www.adobe.com.
Appendix A Specifications and tables
This appendix provides a couple lists of sensor names and a quick reference chart
for operating the Simon XT system with various peripheral devices.
In this appendix:
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Sensor names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Simon XT system quick reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
72
Simon XT
Installation Manual
Specifications
Table 37. Simon XT specifications
Requirement
Description
Power
9 VAC, 60 Hz, 3.34 A transformer
Rechargeable battery: 6.0 VDC, 1.2 Ah lead-acid. The battery will last 24 hours with no AC
and specified standby load of 250 mA. Maximum battery charging current is 45 mA. With
loss of AC panel will continue to operate normally to a minimum of 5.1 VDC.
Radio frequency
319.5 MHz
Storage temperature range
-29 to140°F (-34 to 60°C)
Operating temperature range
32 to 120°F (0 to 49°C)
Maximum humidity
85% relative humidity, noncondensing
Auxiliary power
Unregulated 5.3 to 12.3 VDC, with a maximum of 250 mA
Size (L x W x D)
7 x 5.75 x 2.125 in. (178 x 146 x 54 mm)
Sensor names
Table 38 below and Table 39 on page 73 provide alphabetical and numerically sequential lists of the sensor
name segments.
Table 38. Alphabetical list of sensor name segments
Phrase
Phrase
Phrase
039
Attic
003
Front window
041
Module
004
Back door
028
Garage
024
Office
005
Back window
006
Garage door
025
Office window
030
Basement
007
Garage window
023
Patio door
031
Basement window
012
Guest room
042
Phone module
010
Bedroom
013
Guest room window
021
Porch
011
Bedroom window
036
Hallway
022
Porch window
014
Child’s room
000
Keyfob (keychain)
029
Special chime
015
Child’s room window
019
Kitchen
040
System panic
038
Closet
020
Kitchen window
001
Touchpad
026
Den
017
Living room
032
Upstairs
027
Den window
018
Living room window
033
Upstairs window
034
Downstairs
008
Master bedroom
016
Utility room
035
Downstairs window
009
Master bedroom window
002
Front door
037
Medicine cabinet
73
Table 39. Sensor name segments by index number (in scrolling order)
Phrase
Phrase
Phrase
000
Keyfob (keychain)
043
086
001
Touchpad
044
087
002
Front door
045
088
003
Front window
046
089
004
Back door
047
090
“
005
Back window
048
091
006
Garage door
049
092
007
Garage window
050
093
008
Master bedroom
051
094
009
Master bedroom window
052
095
010
Bedroom
053
096
011
Bedroom window
054
097
012
Guest room
055
098
013
Guest room window
056
099
014
Child’s room
057
100
015
Child’s room window
058
101
016
Utility room
059
102
[space]
017
Living room
060
103
018
Living room window
061
104
019
Kitchen
062
105
020
Kitchen window
063
106
021
Porch
064
107
022
Porch window
065
108
023
Patio door
066
109
024
Office
067
110
025
Office window
068
111
026
Den
069
112
027
Den window
070
113
028
Garage
071
114
029
Special chime
072
115
030
Basement
073
116
031
Basement window
074
117
032
Upstairs
075
118
033
Upstairs window
076
119
034
Downstairs
077
120
035
Downstairs window
078
121
036
Hallway
079
122
037
Medicine Cabinet
080
’
123
038
Closet
081
124
039
Attic
082
125
040
System panic
083
126
041
Module
084
127
042
Phone module
085
128
74
Simon XT
Installation Manual
Table 40. Simon XT system quick reference a
Control panel
Level 0: Subdisarm
the system
Enter the master code while the
system is disarmed.
Level 1: Disarm
the system
DISARM, .
Level 2: Arm doors
and windows
DOORS+WINDOWS, 
(if required).
Level 3: Arm
motion sensors
MOTIONS,  (if
required).
Level 4: Arm doors,
windows, motions
DOORS+WINDOWS, 
(if required), MOTIONS.
Activate no delay
DOORS+WINDOWS, DOORS+WINDOWS.
Appends –No Delay to arming level
text.
Activate latchkey
MOTIONS,  (if
required), MOTIONS.
Activate panic
alarm
Press Fire, Emergency, or Police twice
within 3 sec. or hold it for 2 sec.
Check system
status
STATUS
Remote touchpad
Keyfob
Telephone
Disarm
ARM
Doors &
Windows
ARM
Motion
Sensors
–
ARM
Doors &
Windows
–
ARM
Doors &
Windows
–
ARM
Motion
Sensors
ARM
Motion
Sensors
2–3
–
2–2
ARM
Doors &
Windows
ARM
Motion
Sensors
Hold both
for 3 sec.
–
–
Hold both
for 3 sec.
3–3
SYSTEM
STATUS
Toggle chime or
Scroll to Chime or Special Chime,
special chime mode Enter, toggle On/Off, Enter.
Bypass a sensor
BYPASS, , scroll to the
sensor, BYPASS.
Time-activated
lights on/off
Scroll to Light Schedules, Enter, toggle
On/Off, Enter.
Sensor-activated
lights on/off
Scroll to Sensor Lights, Enter, toggle
On/Off, Enter.
Specific light on
Press *, .
– .
*–
.
Specific light off
Press #, .
– .
#–
.
All lights on
To turn on all lights controlled by lamp
modules, press * twice. The panel
displays All Lights On.
–
*–*
All lights off
To turn off all lights controlled by lamp
modules, press # twice. The panel
displays All Lights Off.
–
#–#
a.
A minus sign (–) between buttons means press one then the next; a plus sign (+) between buttons means press both simultaneously.
75
Index
AC power ............................................................................................... 31
handheld touchpads .............................................................................. 2, 4
access codes............................................................................................ 40
hardwired contacts.................................................................................. 25
appliance modules .............................................................................. 2, 32
hardwired device connections ................................................................ 24
audio verification options....................................................................... 54
housecode ............................................................................................... 54
autoarm................................................................................................... 41
back piece ......................................................................................... 22, 23
indoor motion sensors .............................................................................. 3
interior siren ........................................................................................... 25
backup battery ........................................................................................ 30
call wait code.......................................................................................... 44
keyfobs ................................................................................................. 2, 3
ELM keyfobs ........................................................................................ 3
carbon monoxide alarms .......................................................................... 3
central station communication................................................................ 64
clock ....................................................................................................... 38
contrast ................................................................................................... 38
lamp modules ..................................................................................... 2, 32
conventions.............................................................................................. ix
latchkey .................................................................................................. 68
cross-zoning............................................................................................ 10
light control ............................................................................................ 54
line seizure.............................................................................................. 27
lock interval............................................................................................ 56
dial delay ................................................................................................ 44
door/window sensors............................................................................ 2, 3
downloader code..................................................................................... 41
menu navigation ..................................................................................... 36
DSL ........................................................................................................ 27
menu structure ........................................................................................ 36
motion sensor ........................................................................................... 2
emergency button ................................................................................... 35
emergency planning ............................................................................... 16
outdoor motion sensors ............................................................................ 3
Enterprise Downloader....................................................................... 2, 41
panel keys ............................................................................................... 35
factory defaults ....................................................................................... 58
panel, back piece .............................................................................. 22, 23
fire button ............................................................................................... 35
panel, mounting ...................................................................................... 23
firmware revision ................................................................................... 38
personal help buttons................................................................................ 4
freeze sensors ........................................................................................... 3
phone buttons ......................................................................................... 65
phone line wiring.................................................................................... 27
phone numbers ....................................................................................... 43
GFCI....................................................................................................... 31
piezo beep options .................................................................................. 53
ground fault circuit interrupt .................................................................. 31
PIR motion sensor .................................................................................... 2
phone options ......................................................................................... 43
76
Simon XT
Installation Manual
planning .................................................................................................... 6
system components .................................................................................. 3
police button ........................................................................................... 35
system menu ........................................................................................... 35
power transformer wiring ....................................................................... 30
system options ........................................................................................ 51
preface ..................................................................................................... ix
system tests............................................................................................. 57
premises phone ....................................................................................... 28
product, overview..................................................................................... 2
program mode......................................................................................... 39
programming .......................................................................................... 33
technical support .................................................................................... 70
programming codes ................................................................................ 39
technical support centers ........................................................................ 70
testing ..................................................................................................... 59
timers ...................................................................................................... 49
quick reference chart .............................................................................. 74
tripping sensors ...................................................................................... 61
touchpad options .................................................................................... 51
troubleshooting....................................................................................... 68
two-way voice operation ........................................................................ 65
reports..................................................................................................... 47
revision ................................................................................................... 38
universal modules............................................................................... 2, 32
safety terms and symbols ........................................................................ ix
secure arming ......................................................................................... 42
voice event notification .......................................................................... 65
sensors .................................................................................................... 45
deleting............................................................................................... 46
editing ................................................................................................ 46
groups .................................................................................................. 7
learning .............................................................................................. 45
locations............................................................................................... 6
testing................................................................................................. 61
tripping............................................................................................... 61
types ..................................................................................................... 6
siren options ........................................................................................... 52
smoke detectors .................................................................................... 2, 3
water sensors ............................................................................................ 3
X10 modules ...................................................................................... 3, 32
X10 operation ......................................................................................... 54
X10 testing ............................................................................................. 66
77
78
Simon XT
Installation Manual
466-2265 Rev. D
Printed in Mexico

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Copyright                       : GE Security
Marked                          : True
Creator Tool                    : FrameMaker 7.1
Modify Date                     : 2008:03:19 09:52:28-05:00
Create Date                     : 2007:11:29 14:58:21Z
Metadata Date                   : 2008:03:19 09:52:28-05:00
Format                          : application/pdf
Title                           : simonxt-iman.book
Creator                         : 208049320
Document ID                     : uuid:e4d9fbc9-fb85-4e6d-a87e-8949b3c9efa3
Instance ID                     : uuid:ce4f5b61-e7a1-43c8-9bdc-b72f3eb4671d
Has XFA                         : No
Page Count                      : 88
Author                          : 208049320
EXIF Metadata provided by EXIF.tools
FCC ID Filing: B4Z-910C-SIMON